1
|
Characterization of the mechanical properties of the mouse Achilles tendon enthesis by microindentation. Effects of unloading and subsequent reloading. Bone Rep 2024; 20:101734. [PMID: 38292933 PMCID: PMC10825371 DOI: 10.1016/j.bonr.2024.101734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 12/14/2023] [Accepted: 01/03/2024] [Indexed: 02/01/2024] Open
Abstract
The fibrocartilaginous tendon enthesis, i.e. the site where a tendon is attached to bone through a fibrocartilaginous tissue, is considered as a functionally graded interface. However, at local scale, a very limited number of studies have characterized micromechanical properties of this transitional tissue. The first goal of this work was to characterize the micromechanical properties of the mineralized part of the healthy Achilles tendon enthesis (ATE) through microindentation testing and to assess the degree of mineralization and of carbonation of mineral crystals by Raman spectroscopy. Since little is known about enthesis biological plasticity, our second objective was to examine the effects of unloading and reloading, using a mouse hindlimb-unloading model, on both the micromechanical properties and the mineral phase of the ATE. Elastic modulus, hardness, degree of mineralization, and degree of carbonation were assessed after 14 days of hindlimb suspension and again after a subsequent 6 days of reloading. The elastic modulus gradually increased along the mineralized part of the ATE from the tidemark to the subchondral bone, with the same trend being found for hardness. Whereas the degree of carbonation did not differ according to zone of measurement, the degree of mineralization increased by >70 % from tidemark to subchondral bone. Thus, the gradient in micromechanical properties is in part explained by a mineralization gradient. A 14-day unloading period did not appear to affect the gradient of micromechanical properties of the ATE, nor the degree of mineralization or carbonation. However, contrary to a short period of unloading, early return to normal mechanical load reduced the micromechanical properties gradient, regardless of carbonate-to-phosphate ratios, likely due to the more homogeneous degree of mineralization. These findings provide valuable data not only for tissue bioengineering, but also for musculoskeletal clinical studies and microgravity studies focusing on long-term space travel by astronauts.
Collapse
|
2
|
Interspecies comparison of temporomandibular joint condylar cartilage extracellular matrix from macro to microscopy. J Mech Behav Biomed Mater 2023; 145:106007. [PMID: 37451050 DOI: 10.1016/j.jmbbm.2023.106007] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 06/30/2023] [Accepted: 07/03/2023] [Indexed: 07/18/2023]
Abstract
Interspecies comparisons of the extracellular matrix of temporomandibular joint (TMJ) condylar cartilage are necessary to elucidate the mechanisms underlying its superior mechanical properties, to guide the construction of animal models of TMJ-related diseases, and to establish standards for the engineering of TMJ condylar cartilage. Here we characterize and compare TMJ condylar cartilage from six different species from a materials science perspective, including structure, composition and mechanical properties from the macroscopic to the microscopic level. The gross morphology showed obvious interspecies differences in size and shape, which may be related to the different joint motion patterns. Although the condylar cartilage of all species can be divided histologically into a superficial fibrous layer and a deep hyaline layer, there are significant interspecies differences in the microstructure of the fibrils in the two layers, mainly in the diameter of the fibrils. Compositionally, there were no significant differences in collagen composition between species, but the content of glycosaminoglycans (GAGs) decreased progressively with increasing body size, with the same results obtained by Safranin O staining and biochemical analysis. Mechanically, the elastic modulus of mouse condylar cartilage was significantly higher than that of the other species and tended to decrease with increasing body size. This study shows that the TMJ condylar cartilage of different species has its own specific structure-composition-mechanics matching characteristics for their unique masticatory stress dissipation, and differences in fibril diameter and GAGs content may be the two ultimate factors influencing the differences in cartilage mechanical properties between species, while the condylar cartilage of pigs is most similar to that of humans, suggesting that pigs may be a suitable animal model for TMJ studies.
Collapse
|
3
|
Human Cartilage Biomechanics: Experimental and Theoretical Approaches towards the Identification of Mechanical Properties in Healthy and Osteoarthritic Conditions. Processes (Basel) 2023. [DOI: 10.3390/pr11041014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023] Open
Abstract
Articular cartilage is a complex connective tissue with the fundamental functions of load bearing, shock absorption and lubrication in joints. However, traumatic events, aging and degenerative pathologies may affect its structural integrity and function, causing pain and long-term disability. Osteoarthritis represents a health issue, which concerns an increasing number of people worldwide. Moreover, it has been observed that this pathology also affects the mechanical behavior of the articular cartilage. To better understand this correlation, the here proposed review analyzes the physiological aspects that influence cartilage microstructure and biomechanics, with a special focus on the pathological changes caused by osteoarthritis. Particularly, the experimental data on human articular cartilage are presented with reference to different techniques adopted for mechanical testing and the related theoretical mechanical models usually applied to articular cartilage are briefly discussed.
Collapse
|
4
|
Nanomechanical testing in drug delivery: Theory, applications, and emerging trends. Adv Drug Deliv Rev 2022; 183:114167. [PMID: 35183656 DOI: 10.1016/j.addr.2022.114167] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 02/01/2022] [Accepted: 02/14/2022] [Indexed: 11/01/2022]
Abstract
Mechanical properties play a central role in drug formulation development and manufacturing. Traditional characterization of mechanical properties of pharmaceutical solids relied mainly on large compacts, instead of individual particles. Modern nanomechanical testing instruments enable quantification of mechanical properties from the single crystal/particle level to the finished tablet. Although widely used in characterizing inorganic materials for decades, nanomechanical testing has been relatively less employed to characterize pharmaceutical materials. This review focuses on the applications of existing and emerging nanomechanical testing methods in characterizing mechanical properties of pharmaceutical solids to facilitate fast and cost-effective development of high quality drug products. Testing of pharmaceutical materials using nanomechanical techniques holds potential to develop fundamental knowledge in the structure-property relationships of molecular solids, with implications for solid form selection, milling, formulation design, and manufacturing. We also systematically discuss pitfalls and useful tips during sample preparation and testing for reliable measurements from nanomechanical testing.
Collapse
|
5
|
A review of composition‐structure‐function properties and tissue engineering strategies of articular cartilage: compare condyle process and knee‐joint. ADVANCED ENGINEERING MATERIALS 2022. [DOI: 10.1002/adem.202200304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
6
|
Bilayered scaffold with 3D printed stiff subchondral bony compartment to provide constant mechanical support for long-term cartilage regeneration. J Orthop Translat 2021; 30:112-121. [PMID: 34722154 PMCID: PMC8526903 DOI: 10.1016/j.jot.2021.09.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 08/29/2021] [Accepted: 09/02/2021] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND/OBJECTIVE We seek to figure out the effect of stable and powerful mechanical microenvironment provided by Ti alloy as a part of subchondral bone scaffold on long-term cartilage regeneration.Methods: we developed a bilayered osteochondral scaffold based on the assumption that a stiff subchondral bony compartment would provide stable mechanical support for cartilage regeneration and enhance subchondral bone regeneration. The subchondral bony compartment was prepared from 3D printed Ti alloy, and the cartilage compartment was created from a freeze-dried collagen sponge, which was reinforced by poly-lactic-co-glycolic acid (PLGA). RESULTS In vitro evaluations confirmed the biocompatibility of the scaffold materials, while in vivo evaluations demonstrated that the mechanical support provided by 3D printed Ti alloy layer plays an important role in the long-term regeneration of cartilage by accelerating osteochondral formation and its integration with the adjacent host tissue in osteochondral defect model at rabbit femoral trochlea after 24 weeks. CONCLUSION Mechanical support provided by 3D printing Ti alloy promotes cartilage regeneration by promoting subchondral bone regeneration and providing mechanical support platform for cartilage synergistically. TRANSLATIONAL POTENTIAL STATEMENT The raw materials used in our double-layer osteochondral scaffolds are all FDA approved materials for clinical use. 3D printed titanium alloy scaffolds can promote bone regeneration and provide mechanical support for cartilage regeneration, which is very suitable for clinical scenes of osteochondral defects. In fact, we are conducting clinical trials based on our scaffolds. We believe that in the near future, the scaffold we designed and developed can be formally applied in clinical practice.
Collapse
|
7
|
Multifaceted Design and Emerging Applications of Tissue Adhesives. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2007663. [PMID: 33956371 DOI: 10.1002/adma.202007663] [Citation(s) in RCA: 78] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 12/04/2020] [Indexed: 05/24/2023]
Abstract
Tissue adhesives can form appreciable adhesion with tissues and have found clinical use in a variety of medical settings such as wound closure, surgical sealants, regenerative medicine, and device attachment. The advantages of tissue adhesives include ease of implementation, rapid application, mitigation of tissue damage, and compatibility with minimally invasive procedures. The field of tissue adhesives is rapidly evolving, leading to tissue adhesives with superior mechanical properties and advanced functionality. Such adhesives enable new applications ranging from mobile health to cancer treatment. To provide guidelines for the rational design of tissue adhesives, here, existing strategies for tissue adhesives are synthesized into a multifaceted design, which comprises three design elements: the tissue, the adhesive surface, and the adhesive matrix. The mechanical, chemical, and biological considerations associated with each design element are reviewed. Throughout the report, the limitations of existing tissue adhesives and immediate opportunities for improvement are discussed. The recent progress of tissue adhesives in topical and implantable applications is highlighted, and then future directions toward next-generation tissue adhesives are outlined. The development of tissue adhesives will fuse disciplines and make broad impacts in engineering and medicine.
Collapse
|
8
|
Stribeck Curve Analysis of Temporomandibular Joint Condylar Cartilage and Disc. J Biomech Eng 2019; 141:1066041. [PMID: 31654071 DOI: 10.1115/1.4045283] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Indexed: 12/29/2022]
Abstract
Temporomandibular joint (TMJ) diseases such as osteoarthritis and disc displacement have no permanent treatment options, but lubrication therapies, used in other joints, could be an effective alternative. However, the healthy TMJ contains fibrocartilage, not hyaline cartilage as is found in other joints. As such, the effect of lubrication therapies in the TMJ is unknown. Additionally, only a few studies have characterized the friction coefficient of the healthy TMJ. Like other cartilaginous tissues, the TMJ condyles and discs are subject to changes in friction coefficient due to fluid pressurization. In addition, the friction coefficient of the TMJ is affected by the sliding direction and anatomic location. However, these previous findings have not been able to identify how all 3 of these parameters (anatomic location, sliding direction, and fluid pressurization) influence changes in friction coefficient. This study used Stribeck curves to identify differences in the friction coefficients of TMJ condyles and discs based on anatomic location, sliding direction, and amount of fluid pressurization (friction mode). Friction coefficients were measured using a cartilage on glass tribometer. Both TMJ condyle and disc friction coefficients were well described by Stribeck curves. These curves changed based on anatomic location, but very few differences in friction coefficients were observed based on sliding direction. TMJ condyles had similar boundary mode and elastoviscous mode friction coefficients to the TMJ disc, and both were lower than hyaline cartilage in other joints. The observed differences here indicate that the surface characteristics of each anatomic region cause differences in friction coefficients.
Collapse
|
9
|
Effect of the anisotropic permeability in the frequency dependent properties of the superficial layer of articular cartilage. Comput Methods Biomech Biomed Engin 2018; 21:635-644. [PMID: 30428711 DOI: 10.1080/10255842.2018.1504214] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Articular cartilage is a tissue of fundamental importance for the mechanics of joints, since it provides a smooth and lubricated surface for the proper transfer of loads. From a mechanical point of view, this tissue is an anisotropic poroviscoelastic material: its characteristics at the macroscopic level depend on the complex microscopic architecture. With the ability to probe the local microscopic features, dynamic nanoindentation test is a powerful tool to investigate cartilage mechanics. In this work we focus on a length scale where the time dependent behaviour is regulated by poroelasticity more than viscoelasticity and we aim to understand the effect of the anisotropic permeability on the mechanics of the superficial layer of the articular cartilage. In a previous work, a finite element model for the dynamic nanoindentation test has been presented. In this work, we improve the model by considering the presence of an anisotropic permeability tensor that depends on the collagen fibers distribution. Our sensitivity analysis highlights that the permeability decreases with increasing indentation, thus making the tissue stiffer than the case of isotropic permeability, when solicited at the same frequency. With this improved model, a revised identification of the mechanical and physical parameters for articular cartilage is provided. To this purpose the model was used to simulate experimental data from tests performed on bovine tissue, giving a better estimation of the anisotropy in the elastic properties. A relation between the identified macroscopic anisotropic permeability properties and the microscopic rearrangement of the fiber/matrix structure during indentation is also provided.
Collapse
|
10
|
Mechanical alterations of the bone-cartilage unit in a rabbit model of early osteoarthrosis. J Mech Behav Biomed Mater 2018; 83:1-8. [DOI: 10.1016/j.jmbbm.2018.03.033] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2017] [Revised: 03/19/2018] [Accepted: 03/26/2018] [Indexed: 12/20/2022]
|
11
|
Biomechanical properties of murine TMJ articular disc and condyle cartilage via AFM-nanoindentation. J Biomech 2017; 60:134-141. [PMID: 28688538 DOI: 10.1016/j.jbiomech.2017.06.031] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 06/15/2017] [Accepted: 06/16/2017] [Indexed: 11/24/2022]
Abstract
This study aims to quantify the biomechanical properties of murine temporomandibular joint (TMJ) articular disc and condyle cartilage using AFM-nanoindentation. For skeletally mature, 3-month old mice, the surface of condyle cartilage was found to be significantly stiffer (306±84kPa, mean±95% CI) than those of the superior (85±23kPa) and inferior (45±12kPa) sides of the articular disc. On the disc surface, significant heterogeneity was also detected across multiple anatomical sites, with the posterior end being the stiffest and central region being the softest. Using SEM, this study also found that the surfaces of disc are composed of anteroposteriorly oriented collagen fibers, which are sporadically covered by thinner random fibrils. Such fibrous nature results in both an F-D3/2 indentation response, which is a typical Hertzian response for soft continuum tissue under a spherical tip, and a linear F-D response, which is typical for fibrous tissues, further signifying the high degree of tissue heterogeneity. In comparison, the surface of condyle cartilage is dominated by thinner, randomly oriented collagen fibrils, leading to Hertzian-dominated indentation responses. As the first biomechanical study of murine TMJ, this work will provide a basis for future investigations of TMJ tissue development and osteoarthritis in various murine TMJ models.
Collapse
|
12
|
Abstract
The mandibular condylar cartilage plays an important role as a stress absorber during function. However, relatively little information is available on its dynamic properties under compression. We hypothesized that these properties are region-specific and depend on loading frequency. To characterize the viscoelastic properties of the condylar cartilage, we performed dynamic indentation tests over a wide range of loading frequencies. Ten porcine mandibular condyles were used; the articular surface was divided into 4 regions, anteromedial, anterolateral, posteromedial, and posterolateral. The dynamic complex, storage, and loss moduli increased with frequency, and these values were the highest in the anteromedial region. Loss tangent decreased with frequency from 0.68 to 0.17, but a regional difference was not found. The present results suggest that the dynamic compressive modulus is region-specific and is dependent on the loading frequency, which might have important implications for the transmission of load in the temporomandibular joint.
Collapse
|
13
|
Cyclical compressive stress induces differentiation of rat primary mandibular condylar chondrocytes through phosphorylated myosin light chain II. Mol Med Rep 2016; 14:4293-4300. [PMID: 27748856 DOI: 10.3892/mmr.2016.5788] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Accepted: 09/05/2016] [Indexed: 11/05/2022] Open
Abstract
The role of myosin light chain II (MLC‑II) in cellular differentiation of rat mandibular condylar chondrocytes (MCCs) induced by cyclical uniaxial compressive stress (CUCS) remains unclear. In the current study, a four‑point bending system was used to apply CUCS to primary cultured MCCs from rats. It was identified that CUCS stimulated features of cellular differentiation including morphological alterations, cytoskeleton rearrangement and overproduction of proteoglycans. Furthermore, CUCS promoted runt‑related transcription factor‑2 (RUNX2) expression at mRNA (P<0.01) and protein levels (P<0.05) and elevated alkaline phosphatase (ALP) activity (P<0.01), which are both markers of osteogenic differentiation. Under conditions of stress, western blotting indicated that the ratio of phosphorylated MLC‑II to total MLC‑II was increased significantly (P<0.05). Silencing MLC‑II by RNA interference reduced ALP activity (P<0.01), and eliminated RUNX2 mRNA expression (P<0.01). Addition of the MLC kinase inhibitor, ML‑7, reduced the CUCS‑associated upregulation of RUNX2 expression (P<0.01) and ALP activity (P<0.01). The data indicated that CUCS promoted cellular differentiation of rat primary MCCs, and this was suggested to be via the phosphorylation of MLC‑II.
Collapse
|
14
|
A dynamic nanoindentation technique to investigate the nanomechanical properties of a colored beetle. RSC Adv 2016. [DOI: 10.1039/c6ra14687b] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
15
|
|
16
|
Stress relaxation behaviors of articular cartilages in porcine temporomandibular joint. J Biomech 2014; 47:1582-7. [DOI: 10.1016/j.jbiomech.2014.03.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2014] [Revised: 03/03/2014] [Accepted: 03/03/2014] [Indexed: 11/25/2022]
|
17
|
Temporomandibular disorders: a review of etiology, clinical management, and tissue engineering strategies. Int J Oral Maxillofac Implants 2014; 28:e393-414. [PMID: 24278954 DOI: 10.11607/jomi.te20] [Citation(s) in RCA: 184] [Impact Index Per Article: 18.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Temporomandibular disorders (TMD) are a class of degenerative musculoskeletal conditions associated with morphologic and functional deformities that affect up to 25% of the population, but their etiology and progression are poorly understood and, as a result, treatment options are limited. In up to 70% of cases, TMD are accompanied by malpositioning of the temporomandibular joint (TMJ) disc, termed "internal derangement." Although the onset is not well characterized, correlations between internal derangement and osteoarthritic change have been identified. Because of the complex and unique nature of each TMD case, diagnosis requires patient-specific analysis accompanied by various diagnostic modalities. Likewise, treatment requires customized plans to address the specific characteristics of each patient's disease. In the mechanically demanding and biochemically active environment of the TMJ, therapeutic approaches that can restore joint functionality while responding to changes in the joint have become a necessity. One such approach, tissue engineering, which may be capable of integration and adaptation in the TMJ, carries significant potential for the development of repair and replacement tissues. The following review presents a synopsis of etiology, current treatment methods, and the future of tissue engineering for repairing and/or replacing diseased joint components, specifically the mandibular condyle and TMJ disc. An analysis of native tissue characterization to assist clinicians in identifying tissue engineering objectives and validation metrics for restoring healthy and functional structures of the TMJ is followed by a discussion of current trends in tissue engineering.
Collapse
|
18
|
Deleterious effects of osteoarthritis on the structure and function of the meniscal enthesis. Osteoarthritis Cartilage 2014; 22:275-83. [PMID: 24316288 PMCID: PMC3923977 DOI: 10.1016/j.joca.2013.11.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2013] [Revised: 11/23/2013] [Accepted: 11/26/2013] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The ability of menisci to prevent osteoarthritis (OA) is dependent on the integrity of the complex meniscal entheses, the attachments of the menisci to the underlying subchondral bone (SB). The goal of this study was to determine mechanical and structural changes in meniscal entheses after the onset of OA. DESIGN Healthy and osteoarthritic meniscal entheses were evaluated for changes in histomorphological characteristics, mineralization, and mechanical properties. Glycosaminoglycans (GAG) and calcium in the insertion were evaluated with histological staining techniques. The extent of calcium deposition was assessed and tidemark (TM) integrity was quantified. Changes in the mineralized zone of the insertion were examined using micro-computed tomography (μCT) to determine bone mineral density, cortical zone thickness, and mineralization gradient. Mechanical properties of the entheses were measured using nano-indentation techniques to obtain material properties based on viscoelastic analysis. RESULTS GAG thickness in the calcified fibrocartilage (CFC) zone and calcium content were significantly greater in osteoarthritic anterior meniscal entheses. TM integrity was significantly decreased in OA tissue, particularly in the medial anterior (MA) enthesis. The mineralized zone of osteoarthritic meniscal entheses was significantly thicker than in healthy entheses and showed decreased bone mineral density. Fitting of mineralization data to a sigmoidal Gompertz function revealed a lower rate of increase in mineralization in osteoarthritic tissue. Analysis of viscoelastic mechanical properties revealed increased compliance in osteoarthritic tissue. CONCLUSIONS These data suggest that significant changes occur at meniscal enthesis sites with the onset of OA. Mechanical and structural changes in meniscal entheses may contribute to meniscal extrusion, which has been shown to increase the progression of OA.
Collapse
|
19
|
From meniscus to bone: a quantitative evaluation of structure and function of the human meniscal attachments. Acta Biomater 2013; 9:6322-9. [PMID: 23385217 DOI: 10.1016/j.actbio.2013.01.031] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Revised: 01/16/2013] [Accepted: 01/28/2013] [Indexed: 12/01/2022]
Abstract
Meniscus efficacy at promoting joint congruity and preventing osteoarthritis hinges on enthesis integrity. Gross-scale tensile testing, histomorphometry and magnetic resonance imaging reveal significant differences between the four attachments, implying that each must endure a unique mechanical environment, which dictates their structure. However, little data exists to elucidate how these interfaces have adapted to their complex loading environment, particularly on a relevant scale, as the enthesis transitions through several unique zones in less than a millimeter. In our study we leveraged nanoindentation to determine viscoelastic material properties through the transition zones. Additionally, we employed histological techniques to evaluate the enthesis structure, including collagen organization and interdigitation morphometry. Mechanical evaluation revealed the medial posterior insertion site to be significantly more compliant than others. Collagen fiber orientation and dispersion as well as interdigitation morphometry were significantly different between attachments sites. These findings are clinically relevant as a disproportionate amount of enthesis failure occurs in the medial posterior attachment. Also, meniscal enthesis structure and function will need to be considered in future reparative and replacement strategies in order to recreate native meniscus mechanics and prevent osteoarthritis propagation.
Collapse
|
20
|
Indentation properties and glycosaminoglycan content of human menisci in the deep zone. Acta Biomater 2013; 9:6624-9. [PMID: 23321302 DOI: 10.1016/j.actbio.2012.12.033] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2012] [Revised: 12/10/2012] [Accepted: 12/27/2012] [Indexed: 02/07/2023]
Abstract
Menisci are two crescent shaped fibrocartilaginous structures that provide fundamental load distribution and support within the knee joint. Their unique shape transmits axial stresses (i.e. "body force") into hoop or radial stresses. The menisci are primarily an inhomogeneous aggregate of glycosaminoglycans (GAGs) supporting bulk compression and type I collagen fibrils sustaining tension. It has been shown that the superficial meniscal layers are functionally homogeneous throughout the three distinct regions (anterior, central and posterior) using a 300 μm diameter spherical indenter tip, but the deep zone of the meniscus has yet to be mechanically characterized at this scale. Furthermore, the distribution and content of GAG throughout the human meniscal cross-section have not been examined. This study investigated the mechanical properties, via indentation, of the human deep zone meniscus among three regions of the lateral and medial menisci. The distribution of GAGs through the cross-section was also documented. Results for the deep zone of the meniscus showed the medial posterior region to have a significantly greater instantaneous elastic modulus than the central region. No significant differences in the equilibrium modulus were seen when comparing regions or the hemijoint. Histological results revealed that GAGs are not present until at least ~600 μm from the meniscal surface. Understanding the role and distribution of GAG within the human meniscus in conjunction with the material properties of the meniscus will aid in the design of tissue engineered meniscal replacements.
Collapse
|
21
|
Dynamic compressive properties of articular cartilages in the porcine temporomandibular joint. J Mech Behav Biomed Mater 2013; 23:62-70. [PMID: 23660305 DOI: 10.1016/j.jmbbm.2013.04.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2012] [Revised: 03/27/2013] [Accepted: 04/02/2013] [Indexed: 10/26/2022]
Abstract
The mandibular condylar and temporal cartilages in the temporomandibular joint (TMJ) play an important role as a stress absorber during function. However, relatively little information is available on its viscoelastic properties in dynamic compression, particularly in a physiological range of frequencies. We hypothesized that these properties are region-specific and depend on loading frequency. To characterize the viscoelastic properties of both cartilages, we performed dynamic indentation tests over a wide range of loading frequencies. Nine porcine TMJs were used; the articular surface was divided into five regions: anterior; central; posterior; medial and lateral. Sinusoidal compressive strain was applied with an amplitude of 1.0% and a frequency range between 0.01 and 10 Hz. In both cartilages, the dynamic storage modulus increased with frequency, and the value was the highest in the lateral region. These values of E' in the temporal cartilage were smaller than those in the mandibular condylar cartilage in all five regions except the lateral region. The Loss tangent values were higher in the temporal cartilage (0.35-0.65) than in the mandibular condylar one (0.2-0.45), which means that the temporal cartilage presents higher viscosity. The present results suggest that the dynamic compressive moduli in both cartilages are region-specific and dependent on the loading frequency, which might have important implications for the transmission of load in the TMJ.
Collapse
|
22
|
The jaw adductor muscle complex in teleostean fishes: evolution, homologies and revised nomenclature (osteichthyes: actinopterygii). PLoS One 2013; 8:e60846. [PMID: 23565279 PMCID: PMC3614958 DOI: 10.1371/journal.pone.0060846] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2013] [Accepted: 03/03/2013] [Indexed: 11/25/2022] Open
Abstract
The infraclass Teleostei is a highly diversified group of bony fishes that encompasses 96% of all species of living fishes and almost half of extant vertebrates. Evolution of various morphological complexes in teleosts, particularly those involving soft anatomy, remains poorly understood. Notable among these problematic complexes is the adductor mandibulae, the muscle that provides the primary force for jaw adduction and mouth closure and whose architecture varies from a simple arrangement of two segments to an intricate complex of up to ten discrete subdivisions. The present study analyzed multiple morphological attributes of the adductor mandibulae in representatives of 53 of the 55 extant teleostean orders, as well as significant information from the literature in order to elucidate the homologies of the main subdivisions of this muscle. The traditional alphanumeric terminology applied to the four main divisions of the adductor mandibulae - A1, A2, A3, and Aω - patently fails to reflect homologous components of that muscle across the expanse of the Teleostei. Some features traditionally used as landmarks for identification of some divisions of the adductor mandibulae proved highly variable across the Teleostei; notably the insertion on the maxilla and the position of muscle components relative to the path of the ramus mandibularis trigeminus nerve. The evolutionary model of gain and loss of sections of the adductor mandibulae most commonly adopted under the alphanumeric system additionally proved ontogenetically incongruent and less parsimonious than a model of subdivision and coalescence of facial muscle sections. Results of the analysis demonstrate the impossibility of adapting the alphanumeric terminology so as to reflect homologous entities across the spectrum of teleosts. A new nomenclatural scheme is proposed in order to achieve congruence between homology and nomenclature of the adductor mandibulae components across the entire Teleostei.
Collapse
|
23
|
Cell durotaxis on polyelectrolyte multilayers with photogenerated gradients of modulus. Biomacromolecules 2013; 14:1311-20. [PMID: 23505966 DOI: 10.1021/bm301863a] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Behaviors of rat aortic smooth muscle (A7r5) and human osteosarcoma (U2OS) cells on photo-cross-linked polyelectrolyte multilayers (PEMUs) with uniform, or gradients of, moduli were investigated. The PEMUs were built layer-by-layer with the polycation poly(allylamine hydrochloride) (PAH) and a polyanion poly(acrylic acid) (PAA) that was modified with photoreactive 4-(2-hydroxyethoxy) benzophenone (PAABp). PEMUs with different uniform and gradients of modulus were generated by varying the time of uniform ultraviolet light exposure and by exposure through optical density gradient filters. Analysis of adhesion, morphology, cytoskeletal organization, and motility of the cells on the PEMUs revealed that A7r5 cells established a polarized orientation toward increasing modulus on shallow modulus gradients (approximately 4.7 MPa mm(-1)) and durotaxed toward stiffer regions on steeper gradients (approximately 55 MPa mm(-1)). In contrast, U2OS cells exhibited little orientation or durotaxis on modulus gradients. These results demonstrate the utility of photo-cross-linked PEMUs to direct vascular and osteoblast cell behavior, a potential application for PEMU coatings on biomedical implants.
Collapse
|
24
|
Stress analysis during jaw movement based on vivo computed tomography images from patients with temporomandibular disorders. Int J Oral Maxillofac Surg 2013; 42:386-92. [DOI: 10.1016/j.ijom.2012.07.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2012] [Revised: 04/23/2012] [Accepted: 07/03/2012] [Indexed: 10/28/2022]
|
25
|
Abstract
Articulating cartilage wear plays an important role in cartilage degeneration and osteoarthritis (OA) progression. This study investigated the changes of mechanical properties and surface roughness of sheep cartilages with wear progression at a nanometre scale. Young sheep’s rear legs were subjected to a series of wear tests to generate worn cartilage samples to simulate the OA progression. Atomic force microscopy (AFM) was used to determine the effective indentation modulus and to measure the surface morphology of moist cartilage surfaces. The study has found that the mean effective indentation modulus values of worn cartilages were lower than that of healthy cartilage as the control sample. A medium-to-strong correlation between the effective indentation modulus values and the OA grades has been found. The relation between surface topography and effective indentation modulus values of the cartilage surfaces with OA progression was weakly correlated. The method established in this study can be implemented to investigate the effective indentation modulus values of clinical osteoarthritic cartilages and to assist in the understanding and assessment of OA.
Collapse
|
26
|
Nanoindentation of human meniscal surfaces. J Biomech 2012; 45:2230-5. [PMID: 22789734 DOI: 10.1016/j.jbiomech.2012.06.017] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2012] [Revised: 06/09/2012] [Accepted: 06/12/2012] [Indexed: 10/28/2022]
Abstract
Menisci are crescent shaped fibrocartilaginous structures which support load distribution of the knee. The menisci are specifically designed to fit the contour of the femoral condyles, aiding to disperse the stresses on the tibial plateau and in turn safeguarding the underlying articular cartilage. The importance of the meniscal superficial layer has not been fully revealed and it is suspected that this layer plays a pivotal role for meniscal function. In this study, both femoral (proximal) and tibial (distal) contacting meniscal surfaces were mechanically examined on the nano-level among three distinct regions (anterior, central and posterior) of the lateral and medial menisci. Nanoindentation testing showed no significant differences among regions, surfaces or anatomical locations, possibly elucidating on the homogeneity of the meniscal superficial zone structure (E(instantaneous): 3.17-4.12MPa, E(steady-state): 1.47-1.69MPa). Nanomechanical moduli values were approximately an order of magnitude greater than micro-scale testing derived moduli values. These findings validate the structural homogeneity of the meniscal superficial zone, showing that material properties are statistically similar regardless of meniscal surface and region. Understanding the mechanical behavior of meniscal surfaces is imperative to properly design an effective meniscal replacement.
Collapse
|
27
|
Immunofluorescence-guided atomic force microscopy to measure the micromechanical properties of the pericellular matrix of porcine articular cartilage. J R Soc Interface 2012; 9:2997-3007. [PMID: 22675162 DOI: 10.1098/rsif.2012.0314] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
The pericellular matrix (PCM) is a narrow region that is rich in type VI collagen that surrounds each chondrocyte within the extracellular matrix (ECM) of articular cartilage. Previous studies have demonstrated that the chondrocyte micromechanical environment depends on the relative properties of the chondrocyte, its PCM and the ECM. The objective of this study was to measure the influence of type VI collagen on site-specific micromechanical properties of cartilage in situ by combining atomic force microscopy stiffness mapping with immunofluorescence imaging of PCM and ECM regions in cryo-sectioned tissue samples. This method was used to test the hypotheses that PCM biomechanical properties correlate with the presence of type VI collagen and are uniform with depth from the articular surface. Control experiments verified that immunolabelling did not affect the properties of the ECM or PCM. PCM biomechanical properties correlated with the presence of type VI collagen, and matrix regions lacking type VI collagen immediately adjacent to the PCM exhibited higher elastic moduli than regions positive for type VI collagen. PCM elastic moduli were similar in all three zones. Our findings provide further support for type VI collagen in defining the chondrocyte PCM and contributing to its biological and biomechanical properties.
Collapse
|
28
|
Quasi-linear viscoelastic properties of costal cartilage using atomic force microscopy. Comput Methods Biomech Biomed Engin 2012; 15:475-86. [DOI: 10.1080/10255842.2010.545820] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
29
|
|
30
|
Abstract
Cartilage is a hydrated biomacromolecular fiber composite located at the ends of long bones that enables proper joint lubrication, articulation, loading, and energy dissipation. Degradation of extracellular matrix molecular components and changes in their nanoscale structure greatly influence the macroscale behavior of the tissue and result in dysfunction with age, injury, and diseases such as osteoarthritis. Here, the application of the field of nanomechanics to cartilage is reviewed. Nanomechanics involves the measurement and prediction of nanoscale forces and displacements, intra- and intermolecular interactions, spatially varying mechanical properties, and other mechanical phenomena existing at small length scales. Experimental nanomechanics and theoretical nanomechanics have been applied to cartilage at varying levels of material complexity, e.g., nanoscale properties of intact tissue, the matrix associated with single cells, biomimetic molecular assemblies, and individual extracellular matrix biomolecules (such as aggrecan, collagen, and hyaluronan). These studies have contributed to establishing a fundamental mechanism-based understanding of native and engineered cartilage tissue function, quality, and pathology.
Collapse
|
31
|
Abstract
Atomic force microscopy (AFM) can be used to co-localize mechanical properties and topographical features through property mapping techniques. The most common approach for testing biological materials at the microscale and nanoscale is force mapping, which involves taking individual force curves at discrete sites across a region of interest. The limitations of force mapping include long testing times and low resolution. While newer AFM methodologies, like modulated scanning and torsional oscillation, circumvent this problem, their adoption for biological materials has been limited. This could be due to their need for specialized software algorithms and/or hardware. The objective of this study is to develop a novel force scanning technique using AFM to rapidly capture high-resolution topographical images of soft biological materials while simultaneously quantifying their mechanical properties. Force scanning is a straightforward methodology applicable to a wide range of materials and testing environments, requiring no special modification to standard AFMs. Essentially, if a contact-mode image can be acquired, then force scanning can be used to produce a spatial modulus map. The current study first validates this technique using agarose gels, comparing results to ones achieved by the standard force mapping approach. Biologically relevant demonstrations are then presented for high-resolution modulus mapping of individual cells, cell-cell interfaces, and articular cartilage tissue.
Collapse
|
32
|
Mosaic functionality in a transitional ecomorphology: skull biomechanics in stem Hyaeninae compared to modern South African carnivorans. Biol J Linn Soc Lond 2011. [DOI: 10.1111/j.1095-8312.2010.01602.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
33
|
Spatial mapping of the biomechanical properties of the pericellular matrix of articular cartilage measured in situ via atomic force microscopy. Biophys J 2010; 98:2848-56. [PMID: 20550897 DOI: 10.1016/j.bpj.2010.03.037] [Citation(s) in RCA: 108] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2009] [Revised: 02/15/2010] [Accepted: 03/17/2010] [Indexed: 11/15/2022] Open
Abstract
In articular cartilage, chondrocytes are surrounded by a narrow region called the pericellular matrix (PCM), which is biochemically, structurally, and mechanically distinct from the bulk extracellular matrix (ECM). Although multiple techniques have been used to measure the mechanical properties of the PCM using isolated chondrons (the PCM with enclosed cells), few studies have measured the biomechanical properties of the PCM in situ. The objective of this study was to quantify the in situ mechanical properties of the PCM and ECM of human, porcine, and murine articular cartilage using atomic force microscopy (AFM). Microscale elastic moduli were quantitatively measured for a region of interest using stiffness mapping, or force-volume mapping, via AFM. This technique was first validated by means of elastomeric models (polyacrylamide or polydimethylsiloxane) of a soft inclusion surrounded by a stiff medium. The elastic properties of the PCM were evaluated for regions surrounding cell voids in the middle/deep zone of sectioned articular cartilage samples. ECM elastic properties were evaluated in regions visually devoid of PCM. Stiffness mapping successfully depicted the spatial arrangement of moduli in both model and cartilage surfaces. The modulus of the PCM was significantly lower than that of the ECM in human, porcine, and murine articular cartilage, with a ratio of PCM to ECM properties of approximately 0.35 for all species. These findings are consistent with previous studies of mechanically isolated chondrons, and suggest that stiffness mapping via AFM can provide a means of determining microscale inhomogeneities in the mechanical properties of articular cartilage in situ.
Collapse
|
34
|
Use of microindentation to characterize the mechanical properties of articular cartilage: comparison of biphasic material properties across length scales. Osteoarthritis Cartilage 2010; 18:1051-7. [PMID: 20417292 PMCID: PMC2906658 DOI: 10.1016/j.joca.2010.04.007] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2009] [Revised: 04/09/2010] [Accepted: 04/13/2010] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Small scale mechanical testing techniques offer new possibilities for defining changes in mechanical properties that accompany the morphological, histological, and biochemical abnormalities of osteoarthritis (OA). The goal of this study was to investigate the use of microindentation in characterizing the biphasic material properties of articular cartilage. Direct comparisons of the biphasic properties (E, k and nu) determined using microindentation were made to those determined on the same specimens using standard macroscale testing techniques. METHODS Deep-zone bovine articular cartilage specimens (n=10) were tested in macroscale confined and unconfined compression. For microindentation testing, the biphasic properties were determined by conducting finite element simulations of the microindentation experiments for different combinations of values of biphasic properties and identifying the combination yielding the best match to each microindentation curve. Paired t-tests were performed to compare each of E, k and nu between the macro- and microscale. RESULTS The microscale values for E, k and nu were 0.74 (0.53, 0.95)MPa, 0.66 (0.022, 0.110)x10(-16)m(4)/Ns, and 0.16 (0.08, 0.24), respectively. A significant difference between the macro- and microscale measurements was observed for k (P<0.0001), but not for E or nu (P=0.88, 0.16). CONCLUSIONS The agreement in Young's modulus and Poisson's ratio between the results of the microindentation and macroscale tests supports the use of microindentation for characterization of some of the biphasic material properties of articular cartilage. The observed differences in permeability between macro- and microscales are consistent with evidence in the literature of a length-scale dependence to this property.
Collapse
|
35
|
Particle-induced indentation of the alveolar epithelium caused by surface tension forces. J Appl Physiol (1985) 2010; 109:1179-94. [PMID: 20634359 DOI: 10.1152/japplphysiol.00209.2010] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Physical contact between an inhaled particle and alveolar epithelium at the moment of particle deposition must have substantial effects on subsequent cellular functions of neighboring cells, such as alveolar type-I, type-II pneumocytes, alveolar macrophage, as well as afferent sensory nerve cells, extending their dendrites toward the alveolar septal surface. The forces driving this physical insult are born at the surface of the alveolar air-liquid layer. The role of alveolar surfactant submerging a hydrophilic particle has been suggested by Gehr and Schürch's group (e.g., Respir Physiol 80: 17-32, 1990). In this paper, we extended their studies by developing a further comprehensive and mechanistic analysis. The analysis reveals that the mechanics operating in the particle-tissue interaction phenomena can be explained on the basis of a balance between surface tension force and tissue resistance force; the former tend to move a particle toward alveolar epithelial cell surface, the latter to resist the cell deformation. As a result, the submerged particle deforms the tissue and makes a noticeable indentation, which creates unphysiological stress and strain fields in tissue around the particle. This particle-induced microdeformation could likely trigger adverse mechanotransduction and mechanosensing pathways, as well as potentially enhancing particle uptake by the cells.
Collapse
|
36
|
Biomechanical and biochemical characteristics of the mandibular condylar cartilage. Osteoarthritis Cartilage 2009; 17:1408-15. [PMID: 19477310 DOI: 10.1016/j.joca.2009.04.025] [Citation(s) in RCA: 133] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2008] [Revised: 04/16/2009] [Accepted: 04/29/2009] [Indexed: 02/02/2023]
Abstract
The human masticatory system consists of a mandible which is able to move with respect to the skull at its bilateral temporomandibular joint (TMJ) through contractions of the masticatory muscles. Like other synovial joints, the TMJ is loaded mechanically during function. The articular surface of the mandibular condyle is covered with cartilage that is composed mainly of collagen fibers and proteoglycans. This construction results in a viscoelastic response to loading and enables the cartilage to play an important role as a stress absorber during function. To understand its mechanical functions properly, and to assess its limitations, detailed information about the viscoelastic behavior of the mandibular condylar cartilage is required. The purpose of this paper is to review the fundamental concepts of the biomechanical behavior of the mandibular condylar cartilage. This review consists of four parts. Part 1 is a brief introduction of the structure and function of the mandibular condylar cartilage. In Part 2, the biochemical composition of the mandibular condylar cartilage is summarized. Part 3 explores the biomechanical properties of the mandibular condylar cartilage. Finally, Part 4 relates this behavior to the breakdown mechanism of the mandibular condylar cartilage which is associated with the progression of osteoarthritis in the TMJ.
Collapse
|
37
|
Stress analysis in the mandibular condyle during prolonged clenching: a theoretical approach with the finite element method. Proc Inst Mech Eng H 2009; 223:739-48. [PMID: 19743639 DOI: 10.1243/09544119jeim485] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Parafunctional habits, such as bruxism and prolonged clenching, have been associated with functional overloading in the temporomandibular joint (TMJ), which may result in internal derangement and osteoarthrosis of the TMJ. In this study, the distributions of stress on the mandibular condylar surface during prolonged clenching were examined with TMJ mathematical models. Finite element models were developed on the basis of magnetic resonance images from two subjects with or without anterior disc displacement of the TMJ. Masticatory muscle forces were used as a loading condition for stress analysis during a 10 min clenching. In the asymptomatic model, the stress values in the anterior area (0.100 MPa) and lateral area (0.074 MPa) were relatively high among the five areas at 10 min. In the middle and posterior areas, stress relaxation occurred during the first 2 min. In contrast, the stress value in the lateral area was markedly lower (0.020 MPa) than in other areas in the symptomatic model at 10 min. The largest stress (0.050 MPa) was located in the posterior area. All except the anterior area revealed an increase in stress during the first 2 min. The present result indicates that the displacement of the disc could affect the stress distribution on the condylar articular surface during prolonged clenching, especially in the posterior area, probably leading to the cartilage breakdown on the condylar articular surface.
Collapse
|
38
|
Effects of ultrasound beam angle and surface roughness on the quantitative ultrasound parameters of articular cartilage. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:1344-1351. [PMID: 19541404 DOI: 10.1016/j.ultrasmedbio.2009.03.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2008] [Revised: 02/18/2009] [Accepted: 03/09/2009] [Indexed: 05/27/2023]
Abstract
High-resolution arthroscopic ultrasound imaging provides a potential quantitative technique for the diagnostics of early osteoarthritis. However, an uncontrolled, nonperpendicular angle of an ultrasound beam or the natural curvature of the cartilage surface may jeopardize the reliability of the ultrasound measurements. We evaluated systematically the effect of inclining an articular surface on the quantitative ultrasound parameters. Visually intact (n = 8) and mechanically degraded (n = 6) osteochondral bovine patella samples and spontaneously fibrillated (n = 1) and spontaneously proteoglycan depleted (n = 1) osteochondral human tibial samples were imaged using a 50-MHz scanning acoustic system. The surface of each sample was adjusted to predetermined inclination angles (0, 2, 5 and 7 degrees ) and five ultrasound scan lines along the direction of the inclination were analyzed. For each scan line, reflection coefficient (R), integrated reflection coefficient (IRC) and ultrasound roughness index (URI) were calculated. Nonperpendicularity of the cartilage surface was found to affect R, IRC and URI significantly (p < 0.05). Importantly, all ultrasound parameters were able to distinguish (p < 0.05) the mechanically degraded samples from the intact ones even though the angle of incidence of the ultrasound beam varied between 0 and 5 degrees among the samples. Diagnostically, the present findings are important because the natural curvature of the articular surface varies, and a perfect perpendicularity between the ultrasound beam and the surface of the cartilage may be challenging to achieve in a clinical measurement.
Collapse
|
39
|
Nanoindentation of the insertional zones of human meniscal attachments into underlying bone. J Mech Behav Biomed Mater 2009; 2:339-47. [PMID: 19627840 PMCID: PMC2702768 DOI: 10.1016/j.jmbbm.2008.10.005] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2008] [Revised: 10/14/2008] [Accepted: 10/16/2008] [Indexed: 11/23/2022]
Abstract
The fibrocartilagenous knee menisci are situated between the femoral condyles and tibia plateau and are primarily anchored to the tibia by means of four attachments at the anterior and posterior horns. Strong fixation of meniscal attachments to the tibial plateau provide resistance to extruding forces of the meniscal body, allowing the menisci to assist in load transmission from the femur to the tibia. Clinically, tears and ruptures of the meniscal attachments and insertion to bone are rare. While it has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau, little is known about the material properties of meniscal attachments and the transition in material properties from the meniscus to subchondral bone. The objective of this study was to use nanoindentation to investigate the transition from meniscal attachment into underlying subchondral bone through uncalcified and calcified fibrocartilage. Nanoindentation tests were performed on both the anterior and posterior meniscal insertions to measure the instantaneous elastic modulus and elastic modulus at infinite time. The elastic moduli were found to increase in a bi-linear fashion from the external ligamentous attachment to the subchondral bone. The elastic moduli for the anterior attachments were consistently larger than those for the matching posterior attachments at similar indentation locations. These results show that there is a gradient of stiffness from the superficial zones of the insertion close to the ligamentous attachment into the deeper zones of the bone. This information will be useful in the continued development of successful meniscal replacements and understanding of fixation of the replacements to the tibial plateau.
Collapse
|
40
|
A fiber reinforced poroelastic model of nanoindentation of porcine costal cartilage: A combined experimental and finite element approach. J Mech Behav Biomed Mater 2009; 2:326-37; discussion 337-8. [DOI: 10.1016/j.jmbbm.2008.09.003] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2008] [Revised: 08/26/2008] [Accepted: 09/29/2008] [Indexed: 11/28/2022]
|
41
|
Mechanical properties of bovine articular cartilage under microscale indentation loading from atomic force microscopy. Proc Inst Mech Eng H 2009; 223:339-47. [PMID: 19405439 DOI: 10.1243/09544119jeim516] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Atomic force microscopy (AFM) techniques have been increasingly used for investigating the mechanical properties of articular cartilage. According to the previous studies reporting the microscale Young's modulus under AFM indentation tests, the Hertz contact model has been employed with a sharp conical tip indenter. However, the non-linear microscale behaviour of articular cartilage could not be resolved by the standardized Hertz analysis using small and sharp atomic force microscope tips. Therefore, the objective of this study was to evaluate the microscale Young's modulus of articular cartilage more accurately through a non-Hertzian approach with a spherical tip of 5 microm diameter, and to characterize its microscale mechanical behaviour. This methodology adopted in the present study was proved by the consistent values between the microscale (2 per cent, about 9.3 kPa; 3 per cent, about 17.5kPa) and macroscale (2 per cent, about 8.3kPa; 3 per cent, about 18.3kPa) Young's moduli for 2 per cent and 3 per cent agarose gel (n = 100). Therefore, the microscale Young's modulus evaluated in this study is representative of more accurate measurements of cartilage stiffness at the 600 nm deformation level and corresponds to approximately 30.9 kPa (n = 100). Furthermore, on this level of the microscale deformation, articular cartilage showed depth-dependent and frequency-independent behaviour under AFM indentation loading. These findings reveal the microscale mechanical behaviour of articular cartilage more accurately and can be employed further to design microscale structures of chondrocyte-seeded scaffolds and tissue-engineered cartilage by evaluating their microscale properties.
Collapse
|
42
|
Stress Relaxation Behavior of Mandibular Condylar Cartilage Under High-Strain Compression. J Biomech Eng 2009; 131:061008. [DOI: 10.1115/1.3118776] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
During temporomandibular joint (TMJ) function, the mandibular condylar cartilage plays a prime role in the distribution and absorption of stresses generated over the condyle. Biomechanical characterization of the tissue under compression, however, is still incomplete. The present study investigates the regional variations in the elastic and equilibrium moduli of the condylar cartilage under high strains using unconfined compression and stress relaxation, with aims to facilitate future tissue engineering studies. Porcine condylar cartilages from five regions (anterior, central, lateral, medial, and posterior) were tested under unconfined compression. Elastic moduli were obtained from the linear regions of the stress-strain curves corresponding to the continuous deformation. Equilibrium moduli were obtained from the stress relaxation curves using the Kelvin model. The posterior region was the stiffest, followed by the middle (medial, central, and lateral) regions and the anterior region, respectively. Specifically, in terms of the equilibrium modulus, the posterior region was 1.4 times stiffer than the middle regions, which were in turn 1.7 times stiffer than the anterior region, although only the difference between anterior and posterior regions was statistically significant. No significant differences in stiffness were observed among the medial, central, lateral, and posterior regions. A positive correlation between the thickness and stiffness of the cartilage was observed, reflecting that their regional variations may be related phenomena caused in response to cartilage loading patterns. Condylar cartilage was less stiff under compression than in tension. In addition, condylar cartilage under compression appears to behave in a manner similar to the TMJ disc in terms of the magnitude of moduli and drastic initial drop in stress after a ramp strain.
Collapse
|
43
|
Abstract
Mandibular condylar cartilage functions as the load-bearing, shock-absorbing, lubricating material in temporomandibular joints. Little is known about the precise nature of the biomechanical characteristics of this fibro-cartilaginous tissue. We hypothesized that the fixed charge density associated with proteoglycans that introduces an osmotic pressure inside condylar cartilage will significantly increase the tissue's apparent stiffness. Micro-indentation creep tests were performed on porcine TMJ condylar cartilage at 5 different regions-anterior, posterior, medial, lateral, and central-in physiologic and hypertonic solutions. The intrinsic and apparent mechanical properties, including aggregate modulus, shear modulus, and permeability, were calculated by indentation test data and the biphasic theory. The apparent properties (with osmotic effect) were statistically higher than those of the intrinsic solid matrix (without osmotic effect). Regional variations in fixed charge density, permeability, and mechanical modulus were also calculated for condylar surface. The present results provide important quantitative data on the biomechanical properties of TMJ condylar cartilage.
Collapse
|
44
|
Biomechanical properties of the mandibular condylar cartilage and their relevance to the TMJ disc. J Biomech 2009; 42:405-17. [PMID: 19200995 DOI: 10.1016/j.jbiomech.2008.12.012] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2008] [Revised: 12/16/2008] [Accepted: 12/17/2008] [Indexed: 10/21/2022]
Abstract
Mandibular condylar cartilage plays a crucial role in temporomandibular joint (TMJ) function, which includes facilitating articulation with the TMJ disc, reducing loads on the underlying bone, and contributing to bone remodeling. To improve our understanding of the TMJ function in normal and pathological situations, accurate and validated three-dimensional (3-D) finite element models (FEMs) of the human TMJ may serve as valuable diagnostic tools as well as predictors of thresholds for tissue damage resulting from parafunctional activities and trauma. In this context, development of reliable biomechanical standards for condylar cartilage is crucial. Moreover, biomechanical characteristics of the native tissue are important design parameters for creating functional tissue-engineered replacements. Towards these goals, biomechanical characteristics of the condylar cartilage have been reviewed here, highlighting the structure-function correlations. Structurally, condylar cartilage, like the TMJ disc, exhibits zonal and topographical heterogeneity. Early structural investigations of the condylar cartilage have suggested that the tissue possesses a somewhat transversely isotropic orientation of collagen fibers in the fibrous zone. However, recent tensile and shear evaluations have reported a higher stiffness of the tissue in the anteroposterior direction than in the mediolateral direction, corresponding to an anisotropic fiber orientation comparable to the TMJ disc. In a few investigations, condylar cartilage under compression was found to be stiffer anteriorly than posteriorly. As with the TMJ disc, further compressive characterization is warranted. To draw inferences for human tissue using animal models, establishing stiffness-thickness correlations and regional evaluation of proteoglycan/glycosaminoglycan content may be essential. Efforts directed from the biomechanics community for the characterization of TMJ tissues will facilitate the development of reliable and accurate 3-D FEMs of the human TMJ.
Collapse
|
45
|
|
46
|
Evaluation criteria for musculoskeletal and craniofacial tissue engineering constructs: a conference report. Tissue Eng Part A 2008; 14:2089-104. [PMID: 19093294 PMCID: PMC2809981 DOI: 10.1089/ten.tea.2007.0383] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2007] [Accepted: 06/26/2008] [Indexed: 01/24/2023] Open
Abstract
Over the past 20 years, tissue engineering (TE) has evolved into a thriving research and commercial development field. However, applying TE strategies to musculoskeletal (MSK) and craniofacial tissues has been particularly challenging since these tissues must also transmit loads during activities of daily living. To address this need, organizers invited a small group of bioengineers, surgeons, biologists, and material scientists from academia, industry, and government to participate in a two and half-day conference to develop general and tissue-specific criteria for evaluating new concepts and tissue-engineered constructs, including threshold values of success. Participants were assigned to four breakout groups representing commonly injured tissues, including tendon and ligament, articular cartilage, meniscus and temporomandibular joint, and bone and intervertebral disc. Working in multidisciplinary teams, participants first carefully defined one or two important unmet clinical needs for each tissue type, including current standards of care and the potential impact of TE solutions. The groups then sought to identify important parameters for evaluating repair outcomes in preclinical studies and to specify minimally acceptable values for these parameters. The importance of in vitro TE studies was then discussed in the context of these preclinical studies. Where data were not currently available from clinical, preclinical, or culture studies, the groups sought to identify important areas of preclinical research needed to speed the development process. This report summarizes the findings of the conference.
Collapse
|
47
|
Abstract
Mandibular condylar cartilage plays a crucial role in temporomandibular joint (TMJ) function, which includes facilitating articulation with the temporomandibular joint disc and reducing loads on the underlying bone. The cartilage experiences considerable tensile forces due to direct compression and shear. However, only scarce information is available about its tensile properties. The present study aims to quantify the biomechanical characteristics of the mandibular condylar cartilage to aid future three-dimensional finite element modeling and tissue engineering studies. Porcine condylar cartilage was tested under uniaxial tension in two directions, anteroposterior and mediolateral, with three regions per direction. Stress relaxation behavior was modeled using the Kelvin model and a second-order generalized Kelvin model, and collagen fiber orientation was determined by polarized light microscopy. The stress relaxation behavior of the tissue was biexponential in nature. The tissue exhibited greater stiffness in the anteroposterior direction than in the mediolateral direction as reflected by higher Young's (2.4 times), instantaneous (1.9 times), and relaxed (1.9 times) moduli. No significant differences were observed among the regional properties in either direction. The predominantly anteroposterior macroscopic fiber orientation in the fibrous zone of condylar cartilage correlated well with the biomechanical findings. The condylar cartilage appears to be less stiff and less anisotropic under tension than the anatomically and functionally related TMJ disc. The anisotropy of the condylar cartilage, as evidenced by tensile behavior and collagen fiber orientation, suggests that the shear environment of the TMJ exposes the condylar cartilage to predominantly but not exclusively anteroposterior loading.
Collapse
|
48
|
Characterization of the dynamic shear properties of hyaline cartilage using high-frequency dynamic MR elastography. Magn Reson Med 2008; 59:356-64. [PMID: 18228594 DOI: 10.1002/mrm.21474] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This work evaluated the feasibility of dynamic MR Elastography (MRE) to quantify structural changes in bovine hyaline cartilage induced by selective enzymatic degradation. The ability of the technique to quantify the frequency-dependent response of normal cartilage to shear in the kilohertz range was also explored. Bovine cartilage plugs of 8 mm in diameter were used for this study. The shear stiffness (mu(s)) of each cartilage plug was measured before and after 16 hr of enzymatic treatments by dynamic MRE at 5000 Hz of shear excitation. Collagenase and trypsin were used to selectively affect the collagen and proteoglycans contents of the matrix. Additionally, normal cartilage plugs were tested by dynamic MRE at shear-excitations of 3000-7000 Hz. Measured micro(s) of cartilage plugs showed a significant decrease (-37%, P < 0.05) after collagenase treatment and a significant decrease (-28%, P < 0.05) after trypsin treatment. Furthermore, a near-linear increase (R(2) = 0.9141) in the speed of shear wave propagation with shear-excitation frequency was observed in cartilage, indicating that wave speed is dominated by viscoelastic effects. These experiments suggest that dynamic MRE can provide a sensitive quantitative tool to characterize the degradation process and viscoelastic behavior of cartilage.
Collapse
|
49
|
Principles of cartilage tissue engineering in TMJ reconstruction. Head Face Med 2008; 4:3. [PMID: 18298824 PMCID: PMC2288597 DOI: 10.1186/1746-160x-4-3] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2007] [Accepted: 02/25/2008] [Indexed: 11/10/2022] Open
Abstract
Diseases and defects of the temporomandibular joint (TMJ), compromising the cartilaginous layer of the condyle, impose a significant treatment challenge. Different regeneration approaches, especially surgical interventions at the TMJ's cartilage surface, are established treatment methods in maxillofacial surgery but fail to induce a regeneration ad integrum. Cartilage tissue engineering, in contrast, is a newly introduced treatment option in cartilage reconstruction strategies aimed to heal cartilaginous defects. Because cartilage has a limited capacity for intrinsic repair, and even minor lesions or injuries may lead to progressive damage, biological oriented approaches have gained special interest in cartilage therapy. Cell based cartilage regeneration is suggested to improve cartilage repair or reconstruction therapies. Autologous cell implantation, for example, is the first step as a clinically used cell based regeneration option. More advanced or complex therapeutical options (extracorporeal cartilage engineering, genetic engineering, both under evaluation in pre-clinical investigations) have not reached the level of clinical trials but may be approached in the near future. In order to understand cartilage tissue engineering as a new treatment option, an overview of the biological, engineering, and clinical challenges as well as the inherent constraints of the different treatment modalities are given in this paper.
Collapse
|
50
|
Abstract
Shear stress can result in fatigue, damage, and irreversible deformation of the mandibular condylar cartilage. However, little information is available on its dynamic properties in shear. We tested the hypothesis that the dynamic shear properties of the condylar cartilage depend on the frequency and amplitude of shear strain. Ten porcine mandibular condyles were used for dynamic shear tests. Two cartilage-bone plugs were dissected from each condyle and tested in a simple shear sandwich configuration under a compressive strain of 10%. Sinusoidal shear strain was applied with an amplitude of 1.0, 2.0, and 3.0% and a frequency range between 0.01 and 10 Hz. The magnitudes of the shear dynamic moduli were found to be dependent on the frequency and the shear strain amplitude. They increased with shear strain. tan delta ranged from 0.2 to 0.4, which means that the cartilage is primarily elastic in nature and has a small but not negligible viscosity. In conclusion, the present results show that the shear behavior of the mandibular condylar cartilage is dependent on the frequency and amplitude of the applied shear strain. The observed shear characteristics suggest a significant role of shear strain on the interstitial fluid flow within the cartilage.
Collapse
|