1
|
Udoh II, Ekerenam OO, Daniel EF, Ikeuba AI, Njoku DI, Kolawole SK, Etim IIN, Emori W, Njoku CN, Etim IP, Uzoma PC. Developments in anticorrosive organic coatings modulated by nano/microcontainers with porous matrices. Adv Colloid Interface Sci 2024; 330:103209. [PMID: 38848645 DOI: 10.1016/j.cis.2024.103209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 05/02/2024] [Accepted: 06/03/2024] [Indexed: 06/09/2024]
Abstract
The durability and functionality of many metallic structures are seriously threatened by corrosion, which makes the development of anticorrosive coatings imperative. This state-of-the-art survey explores the recent developments in the field of anticorrosive organic coatings modulated by innovations involving nano/microcontainers with porous matrices. The integration of these cutting-edge delivery systems seeks to improve the protective properties of coatings by enabling controlled release, extended durability, targeted application of corrosion inhibitors, and can be co-constructed to achieve defect filling by polymeric materials. The major highlight of this review is an in-depth analysis of the functionalities provided by porous nano/microcontainers in the active protection and self-healing of anticorrosive coatings, including their performance evaluation. In one case, after 20 days of immersion in 0.1 M NaCl, a scratched coating containing mesoporous silica nanoparticles loaded with an inhibitor benzotriazole and shelled with polydopamine (MSNs-BTA@PDA) exhibited coating restoration indicated by a sustained corrosion resistance rise over an extended period monitored by impedance values at 0.01 Hz frequency, rising from 8.3 × 104 to 7.0 × 105 Ω cm2, a trend assigned to active protection by the release of inhibitors and self-healing capabilities. Additionally, some functions related to anti-fouling and heat preservation by nano/microcontainers are highlighted. Based on the literature survey, some desirable properties, current challenges, and prospects of anticorrosive coatings doped with nano/microcontainers have been summarized. The knowledge gained from this survey will shape future research directions and applications in a variety of industrial areas, in addition to advancing smart corrosion prevention technology.
Collapse
Affiliation(s)
- Inime I Udoh
- The Hempel Foundation Coatings Science and Technology Centre (CoaST), Department of Chemical and Biochemical Engineering, Technical University of Denmark (DTU), 2800 Kgs. Lyngby, Denmark; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria.
| | - Okpo O Ekerenam
- Department of Biochemistry, School of Pure & Applied Sciences, Federal University of Technology, Ikot Abasi, Akwa Ibom State, Nigeria; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria
| | - Enobong F Daniel
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria
| | - Alexander I Ikeuba
- Materials Chemistry Research Group, Department of Pure and Applied Chemistry, University of Calabar, Calabar, Nigeria; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria.
| | - Demian I Njoku
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Hong Kong, SAR, China; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria; Africa Center of Excellence in Future Energies and Electrochemical Systems (ACEFUELS), Federal University of Technology, Owerri, Nigeria; Centre for Corrosion and Protection of Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China; Department of Industrial Chemistry, Madonna University, Elele, Nigeria.
| | - Sharafadeen K Kolawole
- Mechanical Engineering Department, School of Engineering and Technology, Federal Polytechnic, P.M.B 420 Offa, Nigeria; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria.
| | - Ini-Ibehe N Etim
- Marine Chemistry and Corrosion Research Group, Department of Marine Science, Akwa Ibom State University, P. M. B. 1167, Nigeria; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria; Africa Center of Excellence in Future Energies and Electrochemical Systems (ACEFUELS), Federal University of Technology, Owerri, Nigeria
| | - Wilfred Emori
- School of Materials Science and Engineering, Sichuan University of Science and Engineering, Zigong 643000, Sichuan, PR China; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria
| | - Chigoziri N Njoku
- Environmental, Composite and Optimization Research Group, Department of Chemical Engineering, Federal University of Technology, PMB 1526 Owerri, Nigeria; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria; Africa Center of Excellence in Future Energies and Electrochemical Systems (ACEFUELS), Federal University of Technology, Owerri, Nigeria.
| | - Iniobong P Etim
- Department of Physics, University of Calabar, Calabar, Nigeria; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria
| | - Paul C Uzoma
- ZJU-UIUC Institute, International Campus, Zhejiang University, Haining 314400, China; Nigerian Alumni Association of the Institute of Metal Research, Chinese Academy of Sciences (NAAIMCAS), Nigeria; Department of Polymer and Textile Engineering, Federal University of Technology, P.M.B. 1526, Owerri, Nigeria
| |
Collapse
|
2
|
Santana Santos C, Jaato BN, Sanjuán I, Schuhmann W, Andronescu C. Operando Scanning Electrochemical Probe Microscopy during Electrocatalysis. Chem Rev 2023; 123:4972-5019. [PMID: 36972701 PMCID: PMC10168669 DOI: 10.1021/acs.chemrev.2c00766] [Citation(s) in RCA: 38] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
Abstract
Scanning electrochemical probe microscopy (SEPM) techniques can disclose the local electrochemical reactivity of interfaces in single-entity and sub-entity studies. Operando SEPM measurements consist of using a SEPM tip to investigate the performance of electrocatalysts, while the reactivity of the interface is simultaneously modulated. This powerful combination can correlate electrochemical activity with changes in surface properties, e.g., topography and structure, as well as provide insight into reaction mechanisms. The focus of this review is to reveal the recent progress in local SEPM measurements of the catalytic activity of a surface toward the reduction and evolution of O2 and H2 and electrochemical conversion of CO2. The capabilities of SEPMs are showcased, and the possibility of coupling other techniques to SEPMs is presented. Emphasis is given to scanning electrochemical microscopy (SECM), scanning ion conductance microscopy (SICM), electrochemical scanning tunneling microscopy (EC-STM), and scanning electrochemical cell microscopy (SECCM).
Collapse
Affiliation(s)
- Carla Santana Santos
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Bright Nsolebna Jaato
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| | - Ignacio Sanjuán
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Corina Andronescu
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| |
Collapse
|
3
|
Lin YH, Tsai CN, Chen PF, Lin YT, Darvishi S, Girault HH, Lin TY, Liao MY, Lin TE. AI-Assisted Fusion of Scanning Electrochemical Microscopy Images Using Novel Soft Probe. ACS MEASUREMENT SCIENCE AU 2022; 2:576-583. [PMID: 36785775 PMCID: PMC9885998 DOI: 10.1021/acsmeasuresciau.2c00032] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 08/01/2022] [Accepted: 08/02/2022] [Indexed: 06/18/2023]
Abstract
Scanning electrochemical microscopy (SECM) is one of the scanning probe techniques that has attracted considerable attention because of its ability to interrogate surface morphology or electrochemical reactivity. However, the quality of SECM images generally depends on the sizes of the electrodes and many uncontrollable factors. Furthermore, manipulating fragile glass ultramicroelectrodes and blurred images sometimes frustrate researchers. To overcome the challenges of modern SECM, we developed novel soft gold probes and then established the AI-assisted methodology for image fusion. A novel gold microelectrode probe with high softness was developed to scan fragile samples. The distribution of EGFR (protein biomarker) in oral cancer was investigated. Then, we fused the optical microscopic and SECM images to enhance the image quality using Matlab software. However, thousands of fused images were generated by changing the parameters for image fusion, which is annoying for researchers. Thus, a deep learning model was built to select the best-fused images according to the contrast and clarity of the fused images. Therefore, the quality of the SECM images was improved using a novel soft probe and combining the image fusion technique. In the future, a new scanning probe with AI-assisted fused SECM image processing may be interpreted more preciously and contribute to the early detection of cancers.
Collapse
Affiliation(s)
- Yi-Hong Lin
- Institute
of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan
| | - Chih-Ning Tsai
- Institute
of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan
| | - Po-Feng Chen
- Institute
of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan
| | - Yen-Tzu Lin
- Institute
of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan
| | - Sorour Darvishi
- Department
of Chemistry and Chemical Engineering, École
Polytechnique Fédérale de Lausanne (EPFL), Valais Wallis, CH-1950 Sion, Switzerland
| | - Hubert H. Girault
- Department
of Chemistry and Chemical Engineering, École
Polytechnique Fédérale de Lausanne (EPFL), Valais Wallis, CH-1950 Sion, Switzerland
| | - Tung-Yi Lin
- Institute
of Traditional Medicine, National Yang Ming
Chiao Tung University, Taipei 11221, Taiwan
- Biomedical
Industry Ph.D. Program, National Yang Ming
Chiao Tung University, Taipei 11221, Taiwan
| | - Mei-Yi Liao
- Department
of Applied Chemistry, National Pingtung
University, Pingtung 90003, Taiwan
| | - Tzu-En Lin
- Institute
of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan
| |
Collapse
|
4
|
Zhao Z, Martino N, Tagliabue L, Minguzzi A, Vertova A. Facile preparation of robust and multipurpose microelectrodes based on injected epoxy resin. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
5
|
Poderyte M, Ramanavicius A, Valiūnienė A. Scanning electrochemical microscopy based irreversible destruction of living cells. Biosens Bioelectron 2022; 216:114621. [PMID: 36007410 DOI: 10.1016/j.bios.2022.114621] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/18/2022] [Accepted: 08/02/2022] [Indexed: 11/02/2022]
Abstract
In this research, scanning electrochemical microscopy combined with electrochemical impedance spectroscopy has been applied to irreversible electroporation of active yeast cells by causing cell death. This finding is important for the development of irreversible electroporation technique, which could be suitable for the curing of cancerous tissues, because during this research cell death has been achieved using relatively low ultramicro-electrode (UME) voltage, precisely of 2.0 V vs Ag/AgCl,Cl-sat. It was determined that the irreversibly electroporated area of immobilized yeast cells was located directly below the UME and was of approximately 20 times larger width than the diameter of the UME, leaving undamaged cells out of this area. The ability of SECM to move the UME with high accuracy in x, y, and z directions and the ability to use electrodes of various diameters as well as the fact that the diameter of the electroporated area depends on the diameter of the UME and on the distance between the UME and the surface, what offers the possibility to establish targeted electroporation systems for selective treatment of tissues.
Collapse
Affiliation(s)
- Margarita Poderyte
- Vilnius University, Faculty of Chemistry and Geosciences, Institute of Chemistry, Naugarduko 24, Vilnius, LT, 03225, Lithuania
| | - Arunas Ramanavicius
- Vilnius University, Faculty of Chemistry and Geosciences, Institute of Chemistry, Naugarduko 24, Vilnius, LT, 03225, Lithuania
| | - Aušra Valiūnienė
- Vilnius University, Faculty of Chemistry and Geosciences, Institute of Chemistry, Naugarduko 24, Vilnius, LT, 03225, Lithuania.
| |
Collapse
|
6
|
Uses of Scanning Electrochemical Microscopy (SECM) for the Characterization with Spatial and Chemical Resolution of Thin Surface Layers and Coating Systems Applied on Metals: A Review. COATINGS 2022. [DOI: 10.3390/coatings12050637] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
Scanning Electrochemical Microscopy (SECM) is increasingly used in the study and characterization of thin surface films as well as organic and inorganic coatings applied on metals for the collection of spatially- and chemically-resolved information on the localized reactions related to material degradation processes. The movement of a microelectrode (ME) in close proximity to the interface under study allows the application of various experimental procedures that can be classified into amperometric and potentiometric operations depending on either sensing faradaic currents or concentration distributions resulting from the corrosion process. Quantitative analysis can be performed using the ME signal, thus revealing different sample properties and/or the influence of the environment and experimental variables that can be observed on different length scales. In this way, identification of the earlier stages for localized corrosion initiation, the adsorption and formation of inhibitor layers, monitoring of water and specific ions uptake by intact polymeric coatings applied on metals for corrosion protection as well as lixiviation, and detection of coating swelling—which constitutes the earlier stages of blistering—have been successfully achieved. Unfortunately, despite these successful applications of SECM for the characterization of surface layers and coating systems applied on metallic materials, we often find in the scientific literature insufficient or even inadequate description of experimental conditions related to the reliability and reproducibility of SECM data for validation. This review focuses specifically on these features as a continuation of a previous review describing the applications of SECM in this field.
Collapse
|
7
|
Bury AG, Pyle A, Marcuccio F, Turnbull DM, Vincent AE, Hudson G, Actis P. A subcellular cookie cutter for spatial genomics in human tissue. Anal Bioanal Chem 2022; 414:5483-5492. [PMID: 35233697 PMCID: PMC9242960 DOI: 10.1007/s00216-022-03944-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 01/23/2022] [Accepted: 01/31/2022] [Indexed: 11/30/2022]
Abstract
Intracellular heterogeneity contributes significantly to cellular physiology and, in a number of debilitating diseases, cellular pathophysiology. This is greatly influenced by distinct organelle populations and to understand the aetiology of disease, it is important to have tools able to isolate and differentially analyse organelles from precise location within tissues. Here, we report the development of a subcellular biopsy technology that facilitates the isolation of organelles, such as mitochondria, from human tissue. We compared the subcellular biopsy technology to laser capture microdissection (LCM) that is the state-of-the-art technique for the isolation of cells from their surrounding tissues. We demonstrate an operational limit of >20 µm for LCM and then, for the first time in human tissue, show that subcellular biopsy can be used to isolate mitochondria beyond this limit.
Collapse
Affiliation(s)
- Alexander G Bury
- Wellcome Centre for Mitochondrial Research, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK.,Biosciences Institute, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK.,Bragg Centre for Materials Research, University of Leeds, Leeds, LS2 9JT, UK.,School of Electronic and Electrical Engineering, University of Leeds, Leeds, LS2 9JT, UK
| | - Angela Pyle
- Wellcome Centre for Mitochondrial Research, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK.,Translational and Clinical Research Institute, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK
| | - Fabio Marcuccio
- Bragg Centre for Materials Research, University of Leeds, Leeds, LS2 9JT, UK.,School of Electronic and Electrical Engineering, University of Leeds, Leeds, LS2 9JT, UK
| | - Doug M Turnbull
- Wellcome Centre for Mitochondrial Research, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK.,Translational and Clinical Research Institute, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK
| | - Amy E Vincent
- Wellcome Centre for Mitochondrial Research, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK. .,Translational and Clinical Research Institute, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK.
| | - Gavin Hudson
- Wellcome Centre for Mitochondrial Research, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK. .,Biosciences Institute, Medical School, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, UK.
| | - Paolo Actis
- Bragg Centre for Materials Research, University of Leeds, Leeds, LS2 9JT, UK. .,School of Electronic and Electrical Engineering, University of Leeds, Leeds, LS2 9JT, UK.
| |
Collapse
|
8
|
Saikrithika S, Shaju A, Dinesh B, Kumar AS. In-situ scanning electrochemical microscopy interrogation on open-circuit release of toxic Ni2+ ion from Ni-containing carbon nanomaterials and nickel-hexacyanoferrate formation in physiological pH and its thiol-electrocatalysis relevance. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139806] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
9
|
McKenzie ECR, Hosseini S, Petro AGC, Rudman KK, Gerroll BHR, Mubarak MS, Baker LA, Little RD. Versatile Tools for Understanding Electrosynthetic Mechanisms. Chem Rev 2021; 122:3292-3335. [PMID: 34919393 DOI: 10.1021/acs.chemrev.1c00471] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Electrosynthesis is a popular, green alternative to traditional organic methods. Understanding the mechanisms is not trivial yet is necessary to optimize reaction processes. To this end, a multitude of analytical tools is available to identify and quantitate reaction products and intermediates. The first portion of this review serves as a guide that underscores electrosynthesis fundamentals, including instrumentation, electrode selection, impacts of electrolyte and solvent, cell configuration, and methods of electrosynthesis. Next, the broad base of analytical techniques that aid in mechanism elucidation are covered in detail. These methods are divided into electrochemical, spectroscopic, chromatographic, microscopic, and computational. Technique selection is dependent on predicted reaction pathways and electrogenerated intermediates. Often, a combination of techniques must be utilized to ensure accuracy of the proposed model. To conclude, future prospects that aim to enhance the field are discussed.
Collapse
Affiliation(s)
- Eric C R McKenzie
- Department of Chemistry, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Seyyedamirhossein Hosseini
- Department of Chemistry, University of Utah, 315 South 1400 East, Salt Lake City, Utah 84112, United States
| | - Ana G Couto Petro
- Department of Chemistry, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Kelly K Rudman
- Department of Chemistry, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Benjamin H R Gerroll
- Department of Chemistry, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | | | - Lane A Baker
- Department of Chemistry, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - R Daniel Little
- Department of Chemistry, University of California Santa Barbara, Building 232, Santa Barbara, California 93106, United States
| |
Collapse
|
10
|
Karg A, Rößler T, Mark A, Markus P, Lauster T, Helfricht N, Papastavrou G. A Versatile and Simple Approach to Electrochemical Colloidal Probes for Direct Force Measurements. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2021; 37:13537-13547. [PMID: 34752120 DOI: 10.1021/acs.langmuir.1c01557] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The colloidal probe technique, which is based on micrometer-sized colloidal particles that are attached to the end of a cantilever, revolutionized direct force measurements by atomic force microscopy (AFM). Its major advantages are a defined interaction geometry and a high force sensitivity. Here, we present a versatile and simple approach for preparing spherical electrodes in the micrometer range on an otherwise insulated AFM cantilever. Thereby, it becomes possible to combine direct force measurements and potentiostatic control of the probe for various types of electrode materials. Two examples for the use of such electrochemical colloidal probes (eCP) are presented: First, on soft, conductive films of poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) the adhesion behavior was studied. The current through the contact area between the probe and film remained constant until the jump-out of contact, indicating a constant geometrical contact area. Second, the long-range forces due to diffuse layer overlap between an eCP and a glass surface have been determined as a function of the externally applied potential. The resulting interaction force profiles are in good agreement with those calculated based on charge regulation and solutions of the full Poisson-Boltzmann equation.
Collapse
Affiliation(s)
- Andreas Karg
- Physical Chemistry II, University of Bayreuth, Universitätsstrasse 30, 95447 Bayreuth, Germany
- Bavarian Center for Battery Technology, Universitätsstrasse 30, 95447 Bayreuth, Germany
| | - Tamino Rößler
- Physical Chemistry II, University of Bayreuth, Universitätsstrasse 30, 95447 Bayreuth, Germany
| | - Andreas Mark
- Physical Chemistry II, University of Bayreuth, Universitätsstrasse 30, 95447 Bayreuth, Germany
| | - Paul Markus
- Physical Chemistry II, University of Bayreuth, Universitätsstrasse 30, 95447 Bayreuth, Germany
| | - Tobias Lauster
- Physical Chemistry II, University of Bayreuth, Universitätsstrasse 30, 95447 Bayreuth, Germany
| | - Nicolas Helfricht
- Physical Chemistry II, University of Bayreuth, Universitätsstrasse 30, 95447 Bayreuth, Germany
| | - Georg Papastavrou
- Physical Chemistry II, University of Bayreuth, Universitätsstrasse 30, 95447 Bayreuth, Germany
- Bavarian Center for Battery Technology, Universitätsstrasse 30, 95447 Bayreuth, Germany
| |
Collapse
|
11
|
Steimecke M, Araújo‐Cordero AM, Dieterich E, Bron M. Probing Individual Cuprous Oxide Microcrystals towards Carbon Dioxide Reduction by using In Situ Raman‐coupled Scanning Electrochemical Microscopy. ChemElectroChem 2021. [DOI: 10.1002/celc.202101221] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Matthias Steimecke
- Institut für Chemie Technische Chemie I Martin-Luther-Universität Halle-Wittenberg Von-Danckelmann-Platz 4 06120 Halle Germany
| | - Ana María Araújo‐Cordero
- Institut für Chemie Technische Chemie I Martin-Luther-Universität Halle-Wittenberg Von-Danckelmann-Platz 4 06120 Halle Germany
| | - Emil Dieterich
- Institut für Chemie Technische Chemie I Martin-Luther-Universität Halle-Wittenberg Von-Danckelmann-Platz 4 06120 Halle Germany
| | - Michael Bron
- Institut für Chemie Technische Chemie I Martin-Luther-Universität Halle-Wittenberg Von-Danckelmann-Platz 4 06120 Halle Germany
| |
Collapse
|
12
|
Iffelsberger C, Jellett CW, Pumera M. 3D Printing Temperature Tailors Electrical and Electrochemical Properties through Changing Inner Distribution of Graphite/Polymer. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2101233. [PMID: 33938128 DOI: 10.1002/smll.202101233] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 03/24/2021] [Indexed: 05/24/2023]
Abstract
The rise of 3D printing technology, with fused deposition modeling as one of the simplest and most widely used techniques, has empowered an increasing interest for composite filaments, providing additional functionality to 3D-printed components. For future applications, like electrochemical energy storage, energy conversion, and sensing, the tuning of the electrochemical properties of the filament and its characterization is of eminent importance to improve the performance of 3D-printed devices. In this work, customized conductive graphite/poly(lactic acid) filament with a percentage of graphite filler close to the conductivity percolation limit is fabricated and 3D-printed into electrochemical devices. Detailed scanning electrochemical microscopy investigations demonstrate that 3D-printing temperature has a dramatic effect on the conductivity and electrochemical performance due to a changed conducive filler/polymer distribution. This may allow, e.g., 3D printing of active/inactive parts of the same structure from the same filament when changing the 3D printing nozzle temperature. These tailored properties can have profound influence on the application of these 3D-printed composites, which can lead to a dramatically different functionality of the final electrical, electrochemical, and energy storage device.
Collapse
Affiliation(s)
- Christian Iffelsberger
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, Brno, 61200, Czech Republic
| | - Cameron W Jellett
- Center of Advanced Functional Nanorobots, Department of Inorganic Chemistry, Faculty of Chemical Technology, University of Chemistry and Technology in Prague, Technická 5, Prague, 16628, Czech Republic
| | - Martin Pumera
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, Brno, 61200, Czech Republic
- Center of Advanced Functional Nanorobots, Department of Inorganic Chemistry, Faculty of Chemical Technology, University of Chemistry and Technology in Prague, Technická 5, Prague, 16628, Czech Republic
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
- 3D Printing & Innovation Hub, Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, Brno, CZ-613 00, Czech Republic
- Department of Medical Research, China Medical University Hospital, China Medical University, No. 91 Hsueh-Shih Road, Taichung, 40402, Taiwan
| |
Collapse
|
13
|
Bhat SV, Price JDW, Dahms TES. AFM-Based Correlative Microscopy Illuminates Human Pathogens. Front Cell Infect Microbiol 2021; 11:655501. [PMID: 34026660 PMCID: PMC8138568 DOI: 10.3389/fcimb.2021.655501] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 04/08/2021] [Indexed: 12/25/2022] Open
Abstract
Microbes have an arsenal of virulence factors that contribute to their pathogenicity. A number of challenges remain to fully understand disease transmission, fitness landscape, antimicrobial resistance and host heterogeneity. A variety of tools have been used to address diverse aspects of pathogenicity, from molecular host-pathogen interactions to the mechanisms of disease acquisition and transmission. Current gaps in our knowledge include a more direct understanding of host-pathogen interactions, including signaling at interfaces, and direct phenotypic confirmation of pathogenicity. Correlative microscopy has been gaining traction to address the many challenges currently faced in biomedicine, in particular the combination of optical and atomic force microscopy (AFM). AFM, generates high-resolution surface topographical images, and quantifies mechanical properties at the pN scale under physiologically relevant conditions. When combined with optical microscopy, AFM probes pathogen surfaces and their physical and molecular interaction with host cells, while the various modes of optical microscopy view internal cellular responses of the pathogen and host. Here we review the most recent advances in our understanding of pathogens, recent applications of AFM to the field, how correlative AFM-optical microspectroscopy and microscopy have been used to illuminate pathogenicity and how these methods can reach their full potential for studying host-pathogen interactions.
Collapse
Affiliation(s)
- Supriya V Bhat
- Department of Chemistry and Biochemistry, University of Regina, Regina, SK, Canada
| | - Jared D W Price
- Department of Chemistry and Biochemistry, University of Regina, Regina, SK, Canada
| | - Tanya E S Dahms
- Department of Chemistry and Biochemistry, University of Regina, Regina, SK, Canada
| |
Collapse
|
14
|
A Review: Scanning Electrochemical Microscopy (SECM) for Visualizing the Real-Time Local Catalytic Activity. Catalysts 2021. [DOI: 10.3390/catal11050594] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Scanning electrochemical microscopy (SECM) is a powerful scanning probe technique for measuring the in situ electrochemical reactions occurring at various sample interfaces, such as the liquid-liquid, solid-liquid, and liquid-gas. The tip/probe of SECM is usually an ultramicroelectrode (UME) or a nanoelectrode that can move towards or over the sample of interest controlled by a precise motor positioning system. Remarkably, electrocatalysts play a crucial role in addressing the surge in global energy consumption by providing sustainable alternative energy sources. Therefore, the precise measurement of catalytic reactions offers profound insights for designing novel catalysts as well as for enhancing their performance. SECM proves to be an excellent tool for characterization and screening catalysts as the probe can rapidly scan along one direction over the sample array containing a large number of different compositions. These features make SECM more appealing than other conventional methodologies for assessing bulk solutions. SECM can be employed for investigating numerous catalytic reactions including the oxygen reduction reaction (ORR), oxygen evolution reaction (OER), hydrogen evolution reaction (HER), water oxidation, glucose oxidation reaction (GOR), and CO2 reduction reaction (CO2RR) with high spatial resolution. Moreover, for improving the catalyst design, several SECM modes can be applied based on the catalytic reactions under evaluation. This review aims to present a brief overview of the recent applications of electrocatalysts and their kinetics as well as catalytic sites in electrochemical reactions, such as oxygen reduction, water oxidation, and methanol oxidation.
Collapse
|
15
|
Kranz C, Wächtler M. Characterizing photocatalysts for water splitting: from atoms to bulk and from slow to ultrafast processes. Chem Soc Rev 2021; 50:1407-1437. [DOI: 10.1039/d0cs00526f] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
This review provides a comprehensive overview on characterisation techniques for light-driven redox-catalysts highlighting spectroscopic, microscopic, electrochemical and spectroelectrochemical approaches.
Collapse
Affiliation(s)
- Christine Kranz
- Ulm University
- Institute of Analytical and Bioanalytical Chemistry
- 89081 Ulm
- Germany
| | - Maria Wächtler
- Leibniz Institute of Photonic Technology
- Department Functional Interfaces
- 07745 Jena
- Germany
- Friedrich Schiller University Jena
| |
Collapse
|
16
|
Caniglia G, Kranz C. Scanning electrochemical microscopy and its potential for studying biofilms and antimicrobial coatings. Anal Bioanal Chem 2020; 412:6133-6148. [PMID: 32691088 PMCID: PMC7442582 DOI: 10.1007/s00216-020-02782-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 06/08/2020] [Accepted: 06/19/2020] [Indexed: 02/06/2023]
Abstract
Biofilms are known to be well-organized microbial communities embedded in an extracellular polymeric matrix, which supplies bacterial protection against external stressors. Biofilms are widespread and diverse, and despite the considerable large number of publications and efforts reported regarding composition, structure and cell-to-cell communication within biofilms in the last decades, the mechanisms of biofilm formation, the interaction and communication between bacteria are still not fully understood. This knowledge is required to understand why biofilms form and how we can combat them or how we can take advantage of these sessile communities, e.g. in biofuel cells. Therefore, in situ and real-time monitoring of nutrients, metabolites and quorum sensing molecules is of high importance, which may help to fill that knowledge gap. This review focuses on the potential of scanning electrochemical microscopy (SECM) as a versatile method for in situ studies providing temporal and lateral resolution in order to elucidate cell-to-cell communication, microbial metabolism and antimicrobial impact, e.g. of antimicrobial coatings through the study of electrochemical active molecules. Given the complexity and diversity of biofilms, challenges and limitations will be also discussed.
Collapse
Affiliation(s)
- Giada Caniglia
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee, 11, 89081, Ulm, Germany
| | - Christine Kranz
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee, 11, 89081, Ulm, Germany.
| |
Collapse
|
17
|
Monteiro MCO, Jacobse L, Touzalin T, Koper MTM. Mediator-Free SECM for Probing the Diffusion Layer pH with Functionalized Gold Ultramicroelectrodes. Anal Chem 2020; 92:2237-2243. [PMID: 31874560 PMCID: PMC6977089 DOI: 10.1021/acs.analchem.9b04952] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
![]()
Probing
pH gradients during electrochemical reactions is important
to better understand reaction mechanisms and to separate the influence
of pH and pH gradients from intrinsic electrolyte effects. Here, we
develop a pH sensor to measure pH changes in the diffusion layer during
hydrogen evolution. The probe was synthesized by functionalizing a
gold ultramicroelectrode with a self-assembled monolayer of 4-nitrothiophenol
(4-NTP) and further converting it to form a hydroxylaminothiophenol
(4-HATP)/4-nitrosothiophenol (4-NSTP) redox couple. The pH sensing
is realized by recording the tip cyclic voltammetry and monitoring
the Nernstian shift of the midpeak potential. We employ a capacitive
approach technique in our home-built Scanning Electrochemical Microscope
(SECM) setup in which an AC potential is applied to the sample and
the capacitive current generated at the tip is recorded as a function
of distance. This method allows for an approach of the tip to the
electrode that is electrolyte-free and consequently also mediator-free.
Hydrogen evolution on gold in a neutral electrolyte was studied as
a model system. The pH was measured with the probe at a constant distance
from the electrode (ca. 75 μm), while the electrode potential
was varied in time. In the nonbuffered electrolyte used (0.1 M Li2SO4), even at relatively low current densities,
a pH difference of three units is measured between the location of
the probe and the bulk electrolyte. The time scale of the diffusion
layer transient is captured, due to the high time resolution that
can be achieved with this probe. The sensor has high sensitivity,
measuring differences of more than 8 pH units with a resolution better
than 0.1 pH unit.
Collapse
Affiliation(s)
- Mariana C O Monteiro
- Leiden Institute of Chemistry , Leiden University , P.O. Box 9502, 2300 RA , Leiden , The Netherlands
| | - Leon Jacobse
- DESY NanoLab , Deutsches Elektronensynchrotron DESY , Notkestrasse 85 , D-22607 Hamburg , Germany
| | - Thomas Touzalin
- Leiden Institute of Chemistry , Leiden University , P.O. Box 9502, 2300 RA , Leiden , The Netherlands
| | - Marc T M Koper
- Leiden Institute of Chemistry , Leiden University , P.O. Box 9502, 2300 RA , Leiden , The Netherlands
| |
Collapse
|
18
|
Scanning electrochemical microscopy in the development of enzymatic sensors and immunosensors. Biosens Bioelectron 2019; 141:111411. [PMID: 31228730 DOI: 10.1016/j.bios.2019.111411] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 05/24/2019] [Accepted: 06/03/2019] [Indexed: 01/05/2023]
Abstract
Scanning electrochemical microscopy (SECM) is very useful, non-invasive tool for the analysis of surfaces pre-modified with biomolecules or by whole cells. This review focuses on the application of SECM technique for the analysis of surfaces pre-modified with enzymes (horseradish peroxidase, alkaline phosphatase and glucose oxidase) or labelled with antibody-enzyme conjugates. The working principles and operating modes of SECM are outlined. The applicability of feedback, generation-collection and redox competition modes of SECM on surfaces modified by enzymes or labelled with antibody-enzyme conjugates is discussed. SECM is important in the development of miniaturized bioanalytical systems with enzymes, since it can provide information about the local enzyme activity. Technical challenges and advantages of SECM, experimental parameters, used enzymes and redox mediators, immunoassay formats and analytical parameters of enzymatic SECM sensors and immunosensors are reviewed.
Collapse
|
19
|
Towards Determining Kinetics of Annihilation Electrogenerated Chemiluminescence by Concentration-Dependent Luminescent Intensity. JOURNAL OF ANALYSIS AND TESTING 2019. [DOI: 10.1007/s41664-019-00094-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
20
|
Lin J, Daboss S, Blaimer D, Kranz C. Micro-Structured Polydopamine Films via Pulsed Electrochemical Deposition. NANOMATERIALS (BASEL, SWITZERLAND) 2019; 9:E242. [PMID: 30754722 PMCID: PMC6409672 DOI: 10.3390/nano9020242] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 02/04/2019] [Accepted: 02/09/2019] [Indexed: 12/16/2022]
Abstract
Polydopamine (PDA) films are interesting as smart functional materials, and their controlled structured formation plays a significant role in a wide range of applications ranging from cell adhesion to sensing and catalysis. A pulsed deposition technique is reported for micro-structuring polydopamine films using scanning electrochemical microscopy (SECM) in direct mode. Thereby, precise and reproducible film thicknesses of the deposited spots could be achieved ranging from 5.9 +/- 0.48 nm (1 pulse cycle) to 75.4 nm +/- 2.5 nm for 90 pulse cycles. The obtained morphology is different in comparison to films deposited via cyclic voltammetry or films formed by autooxidation showing a cracked blister-like structure for high pulse cycle numbers. The obtained polydopamine spots were investigated in respect to their electrochemical properties using SECM approach curves. Quantitative kinetic data in dependence of the film thickness, the substrate potential, and the used redox species were obtained.
Collapse
Affiliation(s)
- Jing Lin
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
| | - Sven Daboss
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
| | - Dominik Blaimer
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
| | - Christine Kranz
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
| |
Collapse
|
21
|
Bentley CL, Edmondson J, Meloni GN, Perry D, Shkirskiy V, Unwin PR. Nanoscale Electrochemical Mapping. Anal Chem 2018; 91:84-108. [PMID: 30500157 DOI: 10.1021/acs.analchem.8b05235] [Citation(s) in RCA: 107] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
22
|
Shiku H. Electrochemical Biosensing System for Single Cells, Cellular Aggregates and Microenvironments. ANAL SCI 2018; 35:29-38. [PMID: 30473568 DOI: 10.2116/analsci.18sdr01] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Applications of electrochemical biosensing for surveying intact cells and tissues have been focus of attention. Two experimental approaches have been used when performing amperometric measurements on biological cells, the stylus-type microelectrode probes and the electrode-integrated microdevices based on lithographic technologies. For the probe scanning approach, various types of microsensors were developed to monitor localized physical or chemical natures at a variety of surfaces in situ under wet conditions. Scanning electrochemical microscopy (SECM) has been applied for monitoring local oxygen, enzyme activity, and collection of transcripts. For the non-scanning type of approach, electrode array devices allow very rapid response, parallel monitoring, and multi-analyte assay. Sveral topics of on-chip-culture system were introduced especially concerning on gene expression monitoring by reporter system and reconstruction of in vivo-like nature by controlling microenvironments. Electrochemical reporter assay has been demonstrated to monitor the gene expression process of the gene-modified cultured cells. Long-term monitoring of cellular function of spheroids and three dimensionally-cultured cells were carried out by controlling microenvironments on the cellular chip.
Collapse
Affiliation(s)
- Hitoshi Shiku
- Department of Applied Chemistry, Graduate School of Engineering, Tohoku University
| |
Collapse
|
23
|
Conzuelo F, Schulte A, Schuhmann W. Biological imaging with scanning electrochemical microscopy. Proc Math Phys Eng Sci 2018; 474:20180409. [PMID: 30839832 PMCID: PMC6237495 DOI: 10.1098/rspa.2018.0409] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Accepted: 09/04/2018] [Indexed: 12/27/2022] Open
Abstract
Scanning electrochemical microscopy (SECM) is a powerful and versatile technique for visualizing the local electrochemical activity of a surface as an ultramicroelectrode tip is moved towards or over a sample of interest using precise positioning systems. In comparison with other scanning probe techniques, SECM not only enables topographical surface mapping but also gathers chemical information with high spatial resolution. Considerable progress has been made in the analysis of biological samples, including living cells and immobilized biomacromolecules such as enzymes, antibodies and DNA fragments. Moreover, combinations of SECM with comple-mentary analytical tools broadened its applicability and facilitated multi-functional analysis with extended life science capabilities. The aim of this review is to present a brief topical overview on recent applications of biological SECM, with particular emphasis on important technical improvements of this surface imaging technique, recommended applications and future trends.
Collapse
Affiliation(s)
- Felipe Conzuelo
- Analytical Chemistry—Center for Electrochemical Sciences (CES), Faculty for Chemistry and Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, 44780 Bochum, Germany
| | - Albert Schulte
- School of Biomolecular Science and Engineering (BSE), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong 21210, Thailand
| | - Wolfgang Schuhmann
- Analytical Chemistry—Center for Electrochemical Sciences (CES), Faculty for Chemistry and Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, 44780 Bochum, Germany
| |
Collapse
|
24
|
Advances and Perspectives in Chemical Imaging in Cellular Environments Using Electrochemical Methods. CHEMOSENSORS 2018. [DOI: 10.3390/chemosensors6020024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|