1
|
Mi W, Zhang X, Wang B, Sun R, Ma S, Hu Z, Dai X. Absolute protein quantification based on calibrated particle counting using electrospray-differential mobility analysis. Anal Chim Acta 2024; 1304:342534. [PMID: 38637035 DOI: 10.1016/j.aca.2024.342534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 03/13/2024] [Accepted: 03/25/2024] [Indexed: 04/20/2024]
Abstract
The traceability of in vitro diagnostics or drug products is based on the accurate quantification of proteins. In this study, we developed an absolute quantification approach for proteins. This method is based on calibrated particle counting using electrospray-differential mobility analysis (ES-DMA) coupled with a condensation particle counter (CPC). The absolute concentration of proteins was quantified with the observed protein particle number measured with ES-DMA-CPC, and the detection efficiency was determined by calibrators. The measurement performance and quantitative level were verified using two certificated reference materials, BSA and NIMCmAb. The linear regression fit for the detection efficiency values of three reference materials and one highly purified protein (myoglobin, BSA, NIMCmAb and fibrinogen) indicated that the detection efficiency and the particle size distribution of these proteins exhibited a linear relationship. Moreover, to explore the suitability of the detection efficiency-particle size curve for protein quantification, the concentrations of three typical proteinaceous particles, including two high molecular weight proteins (NIST reference material 8671 and D-dimer) and one protein complex (glutathione S-transferase dimer), were determined. This work suggests that this calibrated particle counting method is an efficient approach for nondestructive, rapid and accurate quantification of proteins, especially for measuring proteinaceous particles with tremendous size and without reference standards.
Collapse
Affiliation(s)
- Wei Mi
- National Institute of Metrology, No.18 Beisanhuan Donglu, Beijing, 100029, China.
| | - Xinyi Zhang
- National Institute of Metrology, No.18 Beisanhuan Donglu, Beijing, 100029, China
| | - Bin Wang
- National Institute of Metrology, No.18 Beisanhuan Donglu, Beijing, 100029, China
| | - Ruixue Sun
- College of Life Sciences, China Jiliang University, Xueyuan Street 258, Hangzhou, 310018, China
| | - Shangying Ma
- College of Life Sciences, China Jiliang University, Xueyuan Street 258, Hangzhou, 310018, China
| | - Zhishang Hu
- National Institute of Metrology, No.18 Beisanhuan Donglu, Beijing, 100029, China.
| | - Xinhua Dai
- National Institute of Metrology, No.18 Beisanhuan Donglu, Beijing, 100029, China.
| |
Collapse
|
2
|
Kaltashov IA, Ivanov DG, Yang Y. Mass spectrometry-based methods to characterize highly heterogeneous biopharmaceuticals, vaccines, and nonbiological complex drugs at the intact-mass level. MASS SPECTROMETRY REVIEWS 2024; 43:139-165. [PMID: 36582075 PMCID: PMC10307928 DOI: 10.1002/mas.21829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 11/21/2022] [Accepted: 11/22/2022] [Indexed: 06/17/2023]
Abstract
The intact-mass MS measurements are becoming increasingly popular in characterization of a range of biopolymers, especially those of interest to biopharmaceutical industry. However, as the complexity of protein therapeutics and other macromolecular medicines increases, the new challenges arise, one of which is the high levels of structural heterogeneity that are frequently exhibited by such products. The very notion of the molecular mass measurement loses its clear and intuitive meaning when applied to an extremely heterogenous system that cannot be characterized by a unique mass, but instead requires that a mass distribution be considered. Furthermore, convoluted mass distributions frequently give rise to unresolved ionic signal in mass spectra, from which little-to-none meaningful information can be extracted using standard approaches that work well for homogeneous systems. However, a range of technological advances made in the last decade, such as the hyphenation of intact-mass MS measurements with front-end separations, better integration of ion mobility in MS workflows, development of an impressive arsenal of gas-phase ion chemistry tools to supplement MS methods, as well as the revival of the charge detection MS and its triumphant entry into the field of bioanalysis already made impressive contributions towards addressing the structural heterogeneity challenge. An overview of these techniques is accompanied by critical analysis of the strengths and weaknesses of different approaches, and a brief overview of their applications to specific classes of biopharmaceutical products, vaccines, and nonbiological complex drugs.
Collapse
Affiliation(s)
- Igor A. Kaltashov
- Department of Chemistry, University of Massachusetts-Amherst, Amherst MA 01003
| | - Daniil G. Ivanov
- Department of Chemistry, University of Massachusetts-Amherst, Amherst MA 01003
| | | |
Collapse
|
3
|
Zoratto S, Heuser T, Friedbacher G, Pletzenauer R, Graninger M, Marchetti-Deschmann M, Weiss VU. Adeno-Associated Virus-like Particles' Response to pH Changes as Revealed by nES-DMA. Viruses 2023; 15:1361. [PMID: 37376661 DOI: 10.3390/v15061361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/29/2023] [Accepted: 06/08/2023] [Indexed: 06/29/2023] Open
Abstract
Gas-phase electrophoresis on a nano-Electrospray Gas-phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA) separates single-charged, native analytes according to the surface-dry particle size. A volatile electrolyte, often ammonium acetate, is a prerequisite for electrospraying. Over the years, nES GEMMA has demonstrated its unique capability to investigate (bio-)nanoparticle containing samples in respect to composition, analyte size, size distribution, and particle numbers. Virus-like particles (VLPs), being non-infectious vectors, are often employed for gene therapy applications. Focusing on adeno-associated virus 8 (AAV8) based VLPs, we investigated the response of these bionanoparticles to pH changes via nES GEMMA as ammonium acetate is known to exhibit these changes upon electrospraying. Indeed, slight yet significant differences in VLP diameters in relation to pH changes are found between empty and DNA-cargo-filled assemblies. Additionally, filled VLPs exhibit aggregation in dependence on the applied electrolyte's pH, as corroborated by atomic force microscopy. In contrast, cryogenic transmission electron microscopy did not relate to changes in the overall particle size but in the substantial particle's shape based on cargo conditions. Overall, we conclude that for VLP characterization, the pH of the applied electrolyte solution has to be closely monitored, as variations in pH might account for drastic changes in particles and VLP behavior. Likewise, extrapolation of VLP behavior from empty to filled particles has to be carried out with caution.
Collapse
Affiliation(s)
- Samuele Zoratto
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Thomas Heuser
- Electron Microscopy Facility, Vienna BioCenter Core Facilities GmbH, A-1030 Vienna, Austria
| | - Gernot Friedbacher
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Robert Pletzenauer
- Pharmaceutical Sciences, Baxalta Innovations GmbH (Part of Takeda), A-1221 Vienna, Austria
| | - Michael Graninger
- Pharmaceutical Sciences, Baxalta Innovations GmbH (Part of Takeda), A-1221 Vienna, Austria
| | | | - Victor U Weiss
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| |
Collapse
|
4
|
Steinberger S, Karuthedom George S, Lauková L, Weiss R, Tripisciano C, Marchetti-Deschmann M, Weber V, Allmaier G, Weiss VU. Targeting the Structural Integrity of Extracellular Vesicles via Nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analysis (nES GEMMA). MEMBRANES 2022; 12:872. [PMID: 36135891 PMCID: PMC9501092 DOI: 10.3390/membranes12090872] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 08/26/2022] [Accepted: 08/27/2022] [Indexed: 06/16/2023]
Abstract
Extracellular vesicles (EVs) are in the scientific spotlight due to their potential application in the medical field, ranging from medical diagnosis to therapy. These applications rely on EV stability during isolation and purification-ideally, these steps should not impact vesicle integrity. In this context, we investigated EV stability and particle numbers via nano electrospray gas-phase electrophoretic mobility molecular analysis (nES GEMMA) and nanoparticle tracking analysis (NTA). In nES GEMMA, native, surface-dry analytes are separated in the gas-phase according to the particle size. Besides information on size and particle heterogeneity, particle number concentrations are obtained in accordance with recommendations of the European Commission for nanoparticle characterization (2011/696/EU, 18 October 2011). Likewise, and in contrast to NTA, nES GEMMA enables detection of co-purified proteins. On the other hand, NTA, yielding data on hydrodynamic size distributions, is able to relate particle concentrations, omitting electrolyte exchange (and resulting EV loss), which is prerequisite for nES GEMMA. Focusing on EVs of different origin, we compared vesicles concentrations and stability, especially after electrolyte exchange and size exclusion chromatography (SEC). Co-isolated proteins were detected in most samples, and the vesicle amount varied in dependence on the EV source. We found that depletion of co-purified proteins was achievable via SEC, but was associated with a loss of EVs and-most importantly-with decreased vesicle stability, as detected via a reduced nES GEMMA measurement repeatability. Ultimately, we propose the repeatability of nES GEMMA to yield information on EV stability, and, as a result, we propose that nES GEMMA can yield additional valuable information in EV research.
Collapse
Affiliation(s)
| | - Sobha Karuthedom George
- Center for Biomedical Technology, Department for Biomedical Research, University for Continuing Education Krems, 3500 Krems, Austria
| | - Lucia Lauková
- Center for Biomedical Technology, Department for Biomedical Research, University for Continuing Education Krems, 3500 Krems, Austria
| | - René Weiss
- Center for Biomedical Technology, Department for Biomedical Research, University for Continuing Education Krems, 3500 Krems, Austria
| | - Carla Tripisciano
- Center for Biomedical Technology, Department for Biomedical Research, University for Continuing Education Krems, 3500 Krems, Austria
| | | | - Viktoria Weber
- Center for Biomedical Technology, Department for Biomedical Research, University for Continuing Education Krems, 3500 Krems, Austria
| | - Günter Allmaier
- Institute of Chemical Technologies and Analytics, TU Wien, 1060 Vienna, Austria
| | - Victor U. Weiss
- Institute of Chemical Technologies and Analytics, TU Wien, 1060 Vienna, Austria
| |
Collapse
|
5
|
Deniz F, Ertekin K, Ulucan U. Quantification of airborne concentrations of micro-scale and submicron phosphors in the manufacturing environment by spectrofluorometric method. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02440-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
6
|
Virus-like Particles: Fundamentals and Biomedical Applications. Int J Mol Sci 2022; 23:ijms23158579. [PMID: 35955711 PMCID: PMC9369363 DOI: 10.3390/ijms23158579] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 07/25/2022] [Accepted: 07/29/2022] [Indexed: 02/04/2023] Open
Abstract
Nanotechnology is a fast-evolving field focused on fabricating nanoscale objects for industrial, cosmetic, and therapeutic applications. Virus-like particles (VLPs) are self-assembled nanoparticles whose intrinsic properties, such as heterogeneity, and highly ordered structural organization are exploited to prepare vaccines; imaging agents; construct nanobioreactors; cancer treatment approaches; or deliver drugs, genes, and enzymes. However, depending upon the intrinsic features of the native virus from which they are produced, the therapeutic performance of VLPs can vary. This review compiles the recent scientific literature about the fundamentals of VLPs with biomedical applications. We consulted different databases to present a general scenario about viruses and how VLPs are produced in eukaryotic and prokaryotic cell lines to entrap therapeutic cargo. Moreover, the structural classification, morphology, and methods to functionalize the surface of VLPs are discussed. Finally, different characterization techniques required to examine the size, charge, aggregation, and composition of VLPs are described.
Collapse
|
7
|
Rivas F, Erxleben D, Smith I, Rahbar E, DeAngelis PL, Cowman MK, Hall AR. Methods for isolating and analyzing physiological hyaluronan: a review. Am J Physiol Cell Physiol 2022; 322:C674-C687. [PMID: 35196167 PMCID: PMC8977137 DOI: 10.1152/ajpcell.00019.2022] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/22/2022] [Accepted: 02/22/2022] [Indexed: 01/01/2023]
Abstract
The carbohydrate hyaluronan (or hyaluronic acid, HA) is found in all human tissues and biofluids where it has wide-ranging functions in health and disease that are dictated by both its abundance and size. Consequently, hyaluronan evaluation in physiological samples has significant translational potential. Although the analytical tools and techniques for probing other biomolecules such as proteins and nucleic acids have become standard approaches in biochemistry, those available for investigating hyaluronan are less well established. In this review, we survey methods related to the assessment of native hyaluronan in biological specimens, including protocols for separating it from biological matrices and technologies for determining its concentration and molecular weight.
Collapse
Affiliation(s)
- Felipe Rivas
- Virginia Tech-Wake Forest University School of Biomedical Engineering and Sciences, Wake Forest School of Medicine, Winston-Salem, North Carolina
| | - Dorothea Erxleben
- Virginia Tech-Wake Forest University School of Biomedical Engineering and Sciences, Wake Forest School of Medicine, Winston-Salem, North Carolina
| | - Ian Smith
- Virginia Tech-Wake Forest University School of Biomedical Engineering and Sciences, Wake Forest School of Medicine, Winston-Salem, North Carolina
| | - Elaheh Rahbar
- Virginia Tech-Wake Forest University School of Biomedical Engineering and Sciences, Wake Forest School of Medicine, Winston-Salem, North Carolina
| | - Paul L DeAngelis
- Department of Biochemistry and Molecular Biology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma
| | - Mary K Cowman
- Department of Biomedical Engineering, New York University Tandon School of Engineering, New York, New York
- Department of Orthopedic Surgery, New York University Grossman School of Medicine, New York, New York
| | - Adam R Hall
- Virginia Tech-Wake Forest University School of Biomedical Engineering and Sciences, Wake Forest School of Medicine, Winston-Salem, North Carolina
- Comprehensive Cancer Center, Wake Forest School of Medicine, Winston-Salem, North Carolina
| |
Collapse
|
8
|
Erdogan RT, Alkhaled M, Kaynak BE, Alhmoud H, Pisheh HS, Kelleci M, Karakurt I, Yanik C, Şen ZB, Sari B, Yagci AM, Özkul A, Hanay MS. Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems. ACS NANO 2022; 16:3821-3833. [PMID: 35785967 DOI: 10.1021/acsnano.1c08423] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Cenk Yanik
- Sabancı University, SUNUM Nanotechnology Research and Application Center, 34956 Istanbul, Turkey
| | | | - Burak Sari
- Faculty of Engineering and Natural Sciences, Sabancı University, 34956 Istanbul, Turkey
| | | | - Aykut Özkul
- Faculty of Veterinary Medicine, Department of Virology, Ankara University, 06110 Ankara, Turkey
- Biotechnology Institute, Ankara University, 06135 Ankara, Turkey
| | | |
Collapse
|
9
|
Virus-Like Particles as Preventive and Therapeutic Cancer Vaccines. Vaccines (Basel) 2022; 10:vaccines10020227. [PMID: 35214685 PMCID: PMC8879290 DOI: 10.3390/vaccines10020227] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 01/27/2022] [Accepted: 01/28/2022] [Indexed: 12/04/2022] Open
Abstract
Virus-like particles (VLPs) are self-assembled viral protein complexes that mimic the native virus structure without being infectious. VLPs, similarly to wild type viruses, are able to efficiently target and activate dendritic cells (DCs) triggering the B and T cell immunities. Therefore, VLPs hold great promise for the development of effective and affordable vaccines in infectious diseases and cancers. Vaccine formulations based on VLPs, compared to other nanoparticles, have the advantage of incorporating multiple antigens derived from different proteins. Moreover, such antigens can be functionalized by chemical modifications without affecting the structural conformation or the antigenicity. This review summarizes the current status of preventive and therapeutic VLP-based vaccines developed against human oncoviruses as well as cancers.
Collapse
|
10
|
Prüfert C, Villatoro J, Zühlke M, Beitz T, Löhmannsröben HG. Liquid phase IR-MALDI and differential mobility analysis of nano- and sub-micron particles. Phys Chem Chem Phys 2022; 24:2275-2286. [PMID: 35014991 DOI: 10.1039/d1cp04196g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Infrared matrix-assisted desorption and ionization (IR-MALDI) enables the transfer of sub-micron particles (sMP) directly from suspensions into the gas phase and their characterization with differential mobility (DM) analysis. A nanosecond laser pulse at 2940 nm induces a phase explosion of the aqueous phase, dispersing the sample into nano- and microdroplets. The particles are ejected from the aqueous phase and become charged. Using IR-MALDI on sMP of up to 500 nm in diameter made it possible to surpass the 100 nm size barrier often encountered when using nano-electrospray for ionizing supramolecular structures. Thus, the charge distribution produced by IR-MALDI could be characterized systematically in the 50-500 nm size range. Well-resolved signals for up to octuply charged particles were obtained in both polarities for different particle sizes, materials, and surface modifications spanning over four orders of magnitude in concentrations. The physicochemical characterization of the IR-MALDI process was done via a detailed analysis of the charge distribution of the emerging particles, qualitatively as well as quantitatively. The Wiedensohler charge distribution, which describes the evolution of particle charging events in the gas phase, and a Poisson-derived charge distribution, which describes the evolution of charging events in the liquid phase, were compared with one another with respect to how well they describe the experimental data. Although deviations were found in both models, the IR-MALDI charging process seems to resemble a Poisson-like charge distribution mechanism, rather than a bipolar gas phase charging one.
Collapse
Affiliation(s)
- C Prüfert
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| | - J Villatoro
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| | - M Zühlke
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| | - T Beitz
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| | - H-G Löhmannsröben
- University of Potsdam, Physical Chemistry, Karl-Liebknecht-Str. 24-25, Potsdam, Germany.
| |
Collapse
|
11
|
nES-DMA with Charge-reduction based on Soft X-ray Radiation: Analysis of a Recombinant Monoclonal Antibody. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1182:122925. [PMID: 34543886 DOI: 10.1016/j.jchromb.2021.122925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 08/05/2021] [Accepted: 09/01/2021] [Indexed: 11/22/2022]
Abstract
Due to the fast growing importance of monoclonal antibodies in biomedical research, bioanalytics and human therapy, sensitive, fast and reliable methods are needed to monitor their production, target their characteristics, and for their final quality control. Application of a nano electrospray (nES) with soft X-ray radiation (SXR) based charge reduction and differential mobility analysis (DMA, aka nano electrospray gas-phase electrophoretic mobility molecular analysis, nES GEMMA) allows the size-separation and detection of macromolecules and (bio-)nanoparticles from a few nm up to several hundreds of nm in diameter in a native-like environment. The current study focuses on the analysis of a 148 kDa recombinant monoclonal antibody (rmAb) with the above mentioned instrumental setup and applying an universal detector, i.e. a water-based condensation particle detector (CPC). Next to the intact rmAb, its aggregates and fragment products after digestion with IdeS protease were analyzed. Additionally, influence of temperature treatment and pH variation on the stability of the rmAb was monitored. In this context, changes in electrophoretic mobility diameter (EMD) values, peak shape, and signal intensity based on particle numbers were of interest. Molecular weights calculated by application of a correlation derived from respective standard protein compounds were compared to mass spectrometric values and were found to be in good accordance. To conclude, we demonstrate that nES-DMA is a valuable tool in the characterization and quality control of rmABs.
Collapse
|
12
|
Fernandez de la Mora J, Angel DM, Peccia J. How Narrow Is the Gas Phase Mobility Distribution of Enveloped Viruses? The Case of the Φ6 Bacteriophage. Anal Chem 2021; 93:12938-12943. [PMID: 34520175 DOI: 10.1021/acs.analchem.1c02402] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
We use the Φ6 bacteriophage previously exploited as a BSL-1 surrogate of severe acute respiratory syndrome coronavirus (SARS-CoV) and Middle East respiratory syndrome (MERS) coronavirus to obtain the first high-resolution gas phase mobility spectra of an enveloped virus. The relative full width at half-maximum found for the viral mobility distribution (FWHMZ < 3.7%) is substantially narrower than that reported by prior mobility or microscopy studies with other enveloped viruses. It is nevertheless not as narrow as that recently found for several non-enveloped viruses (FWHMZ ≈ 2%), presumably due to particle to particle variability of enveloped viruses. This 3.7% is an upper bound to the actual width. Nevertheless, the well-defined mobility peaks obtained indicate that gas phase mobility analysis is a more discriminating methodology than that previously demonstrated for physically based non-genetic viral diagnostic of enveloped viruses. These results are obtained by analysis of the original cell culture medium containing the virus, purified only by passage through a 0.22 μm filter and by dialysis into a 10 mM aqueous ammonium acetate buffer. We confirmed that this buffer exchange preserves infectivity. Therefore, the 63.7 nm mobility diameter found, although smaller than the 75 nm previously inferred by microscopy, corresponds to the full particle including the envelope.
Collapse
Affiliation(s)
- Juan Fernandez de la Mora
- Department of Mechanical Engineering and Materials Science, Yale University, Mason Laboratory, 9 Hillhouse Avenue, New Haven, Connecticut 06520-8286, United States
| | - Darryl Marissa Angel
- Department of Chemical and Environmental Engineering, Yale University, New Haven, Connecticut 06511, United States
| | - Jordan Peccia
- Department of Chemical and Environmental Engineering, Yale University, New Haven, Connecticut 06511, United States
| |
Collapse
|
13
|
Zoratto S, Weiss VU, van der Horst J, Commandeur J, Buengener C, Foettinger‐Vacha A, Pletzenauer R, Graninger M, Allmaier G. Molecular weight determination of adeno-associate virus serotype 8 virus-like particle either carrying or lacking genome via native nES gas-phase electrophoretic molecular mobility analysis and nESI QRTOF mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4786. [PMID: 34608711 PMCID: PMC9285973 DOI: 10.1002/jms.4786] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Accepted: 09/13/2021] [Indexed: 06/13/2023]
Abstract
Virus-like particles (VLPs) are proteinaceous shells derived from viruses lacking any viral genomic material. Adeno-associated virus (AAV) is a non-enveloped icosahedral virus used as VLP delivery system in gene therapy (GT). Its success as vehicle for GT is due to its selective tropism, high level of transduction, and low immunogenicity. In this study, two preparations of AAV serotype 8 (AAV8) VLPs either carrying or lacking completely genomic cargo (i.e., non-viral ssDNA) have been investigated by means of a native nano-electrospray gas-phase electrophoretic mobility molecular analyzer (GEMMA) (native nES GEMMA) and native nano-electrospray ionization quadrupole reflectron time-of-flight mass spectrometry (MS) (native nESI QRTOF MS). nES GEMMA is based on electrophoretic mobility principles: single-charge nanoparticles (NPs), that is, AAV8 particle, are separated in a laminar sheath flow of dry, particle-free air and a tunable orthogonal electric field. Thus, the electrophoretic mobility diameter (EMD) of a bio-NP (i.e., diameter of globular nano-objects) is obtained at atmospheric pressure, which can be converted into its MW based on a correlation. First is the native nESI QRTOF. MS's goal is to keep the native biological conformation of an analyte during the passage into the vacuum. Subsequently, highly accurate MW values are obtained from multiple-charged species after deconvolution. However, once applied to the analysis of megadalton species, native MS is challenging and requires customized instrumental modifications not readily available on standard devices. Hence, the analysis of AAV8 VLPs via native MS in our hands did not produce a defined charge state assignment, that is, charge deconvolution for exact MW determination was not possible. Nonetheless, the method we present is capable to estimate the MW of VLPs by combining the results from native nES GEMMA and native ESI QRTOF MS. In detail, our findings show a MW of 3.7 and 5.0 MDa for AAV8 VLPs either lacking or carrying an engineered genome, respectively.
Collapse
Affiliation(s)
- Samuele Zoratto
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | - Victor U. Weiss
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | | | | | - Carsten Buengener
- Pharmaceutical SciencesBaxalta Innovations (part of Takeda)ViennaAustria
| | | | - Robert Pletzenauer
- Pharmaceutical SciencesBaxalta Innovations (part of Takeda)ViennaAustria
| | - Michael Graninger
- Pharmaceutical SciencesBaxalta Innovations (part of Takeda)ViennaAustria
| | - Guenter Allmaier
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| |
Collapse
|
14
|
Miller LM, Bond KM, Draper BE, Jarrold MF. Characterization of Classical Vaccines by Charge Detection Mass Spectrometry. Anal Chem 2021; 93:11965-11972. [PMID: 34435777 DOI: 10.1021/acs.analchem.1c01893] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Vaccines induce immunity by presenting disease antigens through several platforms ranging from individual protein subunits to whole viruses. Due to the large difference in antigen size, the analytical techniques employed for vaccine characterization are often platform-specific. A single, robust analytical technique capable of widespread, cross-platform use would be of great benefit and allow for comparisons across manufacturing processes. One method that spans the antigen mass range is charge detection mass spectrometry (CDMS). CDMS is a single-ion approach where the mass-to-charge ratio (m/z) and charge are measured simultaneously, allowing accurate mass distributions to be measured for heterogeneous analytes over a broad size range. In this work, CDMS was used to characterize the antigens from three classical multivalent vaccines, inactivated poliomyelitis vaccine (IPOL), RotaTeq, and Gardasil-9, directly from commercial samples. For each vaccine, the antigen purity was inspected, and in the whole virus vaccines, empty virus particles were detected. For IPOL, information on the extent of formaldehyde cross-linking was obtained. RotaTeq shows a narrow peak at 61.06 MDa. This is at a slightly lower mass than expected for the double-layer particle, suggesting that around 10 pentonal trimers are missing. For Gardasil-9, buffer exchange of the vaccine resulted in very broad mass distributions. However, removal of the virus-like particles from the aluminum adjuvant using a displacement reaction generated a spectrum with narrow peaks.
Collapse
Affiliation(s)
- Lohra M Miller
- Chemistry Department, Indiana University, 800 E Kirkwood Ave., Bloomington, Indiana 47405, United States
| | - Kevin M Bond
- Chemistry Department, Indiana University, 800 E Kirkwood Ave., Bloomington, Indiana 47405, United States
| | - Benjamin E Draper
- Megadalton Solutions, 3750 E Bluebird Lane, Bloomington, Indiana 47401, United States
| | - Martin F Jarrold
- Chemistry Department, Indiana University, 800 E Kirkwood Ave., Bloomington, Indiana 47405, United States
| |
Collapse
|
15
|
White N, Seelig JD, Loyalka SK. Computation of drag and diffusion coefficient for coronavirus: I. JOURNAL OF AEROSOL SCIENCE 2021; 157:105806. [PMID: 33976456 PMCID: PMC8103743 DOI: 10.1016/j.jaerosci.2021.105806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 04/23/2021] [Accepted: 04/27/2021] [Indexed: 06/12/2023]
Abstract
Monte Carlo simulations and integral equation techniques allow for the flexible and efficient computation of drag and diffusion coefficients for virus mimetic particles. We highlight a Monte Carlo method that is useful for computing the drag on biomimetic particles in the free-molecular regime and a numerical technique to solve a boundary integral equation (related to the Stokes equation) in the hydrodynamic limit. The free-molecular and the continuum results allow the construction of an approximation for the drag applicable over the full range of Knudsen numbers. Finally, we outline how this work will be useful in modeling viral transport in air and fluids and in viral morphology measurements and in viral separations via electrospray-differential mobility analyzers (ES-DMA).
Collapse
Affiliation(s)
- Nathan White
- Department of Mechanical & Aerospace Engineering, Lafferre Hall, University of Missouri, Columbia, MO, 65211, USA
| | | | - Sudarshan K Loyalka
- Department of Mechanical & Aerospace Engineering, Lafferre Hall, University of Missouri, Columbia, MO, 65211, USA
| |
Collapse
|
16
|
Abstract
![]()
Native mass spectrometry
(MS) involves the analysis and characterization
of macromolecules, predominantly intact proteins and protein complexes,
whereby as much as possible the native structural features of the
analytes are retained. As such, native MS enables the study of secondary,
tertiary, and even quaternary structure of proteins and other biomolecules.
Native MS represents a relatively recent addition to the analytical
toolbox of mass spectrometry and has over the past decade experienced
immense growth, especially in enhancing sensitivity and resolving
power but also in ease of use. With the advent of dedicated mass analyzers,
sample preparation and separation approaches, targeted fragmentation
techniques, and software solutions, the number of practitioners and
novel applications has risen in both academia and industry. This review
focuses on recent developments, particularly in high-resolution native
MS, describing applications in the structural analysis of protein
assemblies, proteoform profiling of—among others—biopharmaceuticals
and plasma proteins, and quantitative and qualitative analysis of
protein–ligand interactions, with the latter covering lipid,
drug, and carbohydrate molecules, to name a few.
Collapse
Affiliation(s)
- Sem Tamara
- Biomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, University of Utrecht, Padualaan 8, 3584 CH Utrecht, The Netherlands.,Netherlands Proteomics Center, Padualaan 8, 3584 CH Utrecht, The Netherlands
| | - Maurits A den Boer
- Biomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, University of Utrecht, Padualaan 8, 3584 CH Utrecht, The Netherlands.,Netherlands Proteomics Center, Padualaan 8, 3584 CH Utrecht, The Netherlands
| | - Albert J R Heck
- Biomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, University of Utrecht, Padualaan 8, 3584 CH Utrecht, The Netherlands.,Netherlands Proteomics Center, Padualaan 8, 3584 CH Utrecht, The Netherlands
| |
Collapse
|
17
|
Zoratto S, Weiss VU, Friedbacher G, Buengener C, Pletzenauer R, Foettinger-Vacha A, Graninger M, Allmaier G. Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy. ACS OMEGA 2021; 6:16428-16437. [PMID: 34235314 PMCID: PMC8246466 DOI: 10.1021/acsomega.1c01443] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/27/2021] [Indexed: 05/30/2023]
Abstract
Adeno-associated virus (AAV)-based virus-like particles (VLPs) are thriving vectors of choice in the biopharmaceutical field of gene therapy. Here, a method to investigate purified AAV serotype 8 (AAV8) batches via a nanoelectrospray gas-phase mobility molecular analyzer (nES GEMMA), also known as an nES differential mobility analyzer, is presented. Indeed, due to AAV's double-digit nanometer scale, nES GEMMA is an excellently suited technique to determine the surface-dry particle size termed electrophoretic mobility diameter of such VLPs in their native state at atmospheric pressure and with particle-number-based detection. Moreover, asymmetric flow field-flow fractionation (AF4, also known as AFFFF) and atomic force microscopy (AFM) techniques were employed as orthogonal techniques for VLP characterization. In addition, AF4 was implemented to size-separate as well as to enrich and collect fractions of AAV8 VLPs after inducing analyte aggregation in the liquid phase. Bionanoparticle aggregation was achieved by a combination of heat and shear stress. These fractions were later analyzed with nES GEMMA (in the gas phase) and AFM (on a solid surface). Both techniques confirm the presence of dimers, trimers, and putative VLP oligomers. Last, AFM reveals even larger AAV8 VLP aggregates, which were not detectable by nES GEMMA because their heterogeneity combined with low abundance was below the limit of detection of the instrument. Hence, the combination of the employed orthogonal sizing methods with the separation technique AF4 allow a comprehensive characterization of AAV8 VLPs applied as vectors.
Collapse
Affiliation(s)
- Samuele Zoratto
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Victor U. Weiss
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Gernot Friedbacher
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Carsten Buengener
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Robert Pletzenauer
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Alexandra Foettinger-Vacha
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Michael Graninger
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Guenter Allmaier
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| |
Collapse
|
18
|
Weiss VU, Denderz N, Allmaier G, Marchetti‐Deschmann M. Online hyphenation of size-exclusion chromatography and gas-phase electrophoresis facilitates the characterization of protein aggregates. Electrophoresis 2021; 42:1202-1208. [PMID: 33651392 PMCID: PMC8252587 DOI: 10.1002/elps.202100018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 02/06/2021] [Accepted: 02/07/2021] [Indexed: 11/07/2022]
Abstract
Gas-phase electrophoresis yields size distributions of polydisperse, aerosolized analytes based on electrophoretic principles. Nanometer-sized, surface-dry, single-charged particles are separated in a high laminar sheath flow of particle-free air and an orthogonal tunable electric field. Additionally, nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA) data are particle-number based. Therefore, small particles can be detected next to larger ones without a bias, for example, native proteins next to their aggregates. Analyte transition from the liquid to the gas phase is a method inherent prerequisite. In this context, nonvolatile sample buffers influence results. In the worst case, the (bio-)nanoparticle signal is lost due to an increased baseline and unspecific clustering of nonvolatile components. We present a novel online hyphenation of liquid chromatography and gas-phase electrophoresis, coupling a size-exclusion chromatography (SEC) column to an advanced nES GEMMA. Via this novel approach, it is possible to (i) separate analyte multimers already present in liquid phase from aggregates formed during the nES process, (ii) differentiate liquid phase and spray-induced multimers, and (iii) to remove nonvolatile buffer components online before SEC-nES GEMMA analysis. Due to these findings, SEC-nES GEMMA has the high potential to help to understand aggregation processes in biological buffers adding the benefit of actual size determination for noncovalent assemblies formed in solution. As detection and characterization of protein aggregation in large-scale pharmaceutical production or sizing of noncovalently bound proteins are findings directly related to technologically and biologically relevant situations, we proposed the presented method to be a valuable addition to LC-MS approaches.
Collapse
Affiliation(s)
- Victor U. Weiss
- Institute for Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | - Natalia Denderz
- Institute for Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | - Günter Allmaier
- Institute for Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | | |
Collapse
|
19
|
Gimpel AL, Katsikis G, Sha S, Maloney AJ, Hong MS, Nguyen TNT, Wolfrum J, Springs SL, Sinskey AJ, Manalis SR, Barone PW, Braatz RD. Analytical methods for process and product characterization of recombinant adeno-associated virus-based gene therapies. MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT 2021; 20:740-754. [PMID: 33738328 PMCID: PMC7940698 DOI: 10.1016/j.omtm.2021.02.010] [Citation(s) in RCA: 63] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The optimization of upstream and downstream processes for production of recombinant adeno-associated virus (rAAV) with consistent quality depends on the ability to rapidly characterize critical quality attributes (CQAs). In the context of rAAV production, the virus titer, capsid content, and aggregation are identified as potential CQAs, affecting the potency, purity, and safety of rAAV-mediated gene therapy products. Analytical methods to measure these attributes commonly suffer from long turnaround times or low throughput for process development, although rapid, high-throughput methods are beginning to be developed and commercialized. These methods are not yet well established in academic or industrial practice, and supportive data are scarce. Here, we review both established and upcoming analytical methods for the quantification of rAAV quality attributes. In assessing each method, we highlight the progress toward rapid, at-line characterization of rAAV. Furthermore, we identify that a key challenge for transitioning from traditional to newer methods is the scarcity of academic and industrial experience with the latter. This literature review serves as a guide for the selection of analytical methods targeting quality attributes for rapid, high-throughput process characterization during process development of rAAV-mediated gene therapies.
Collapse
Affiliation(s)
- Andreas L Gimpel
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, Switzerland
| | - Georgios Katsikis
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Sha Sha
- Department of Biology, Massachusetts Institute of Technology, Cambridge, MA, USA.,Center for Biomedical Innovation, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Andrew John Maloney
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Moo Sun Hong
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Tam N T Nguyen
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jacqueline Wolfrum
- Center for Biomedical Innovation, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Stacy L Springs
- Center for Biomedical Innovation, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Anthony J Sinskey
- Department of Biology, Massachusetts Institute of Technology, Cambridge, MA, USA.,Center for Biomedical Innovation, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Scott R Manalis
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.,Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.,Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Paul W Barone
- Center for Biomedical Innovation, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Richard D Braatz
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Center for Biomedical Innovation, Massachusetts Institute of Technology, Cambridge, MA, USA
| |
Collapse
|
20
|
Affiliation(s)
- Tobias
P. Wörner
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute of Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Tatiana M. Shamorkina
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute of Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Joost Snijder
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute of Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Albert J. R. Heck
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute of Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| |
Collapse
|
21
|
N-terminal VP1 Truncations Favor T = 1 Norovirus-Like Particles. Vaccines (Basel) 2020; 9:vaccines9010008. [PMID: 33374273 PMCID: PMC7824077 DOI: 10.3390/vaccines9010008] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 12/18/2020] [Accepted: 12/21/2020] [Indexed: 12/20/2022] Open
Abstract
Noroviruses cause immense sporadic gastroenteritis outbreaks worldwide. Emerging genotypes, which are divided based on the sequence of the major capsid protein VP1, further enhance this public threat. Self-assembling properties of the human norovirus major capsid protein VP1 are crucial for using virus-like particles (VLPs) for vaccine development. However, there is no vaccine available yet. Here, VLPs from different variants produced in insect cells were characterized in detail using a set of biophysical and structural tools. We used native mass spectrometry, gas-phase electrophoretic mobility molecular analysis, and proteomics to get clear insights into particle size, structure, and composition, as well as stability. Generally, noroviruses have been known to form mainly T = 3 particles. Importantly, we identified a major truncation in the capsid proteins as a likely cause for the formation of T = 1 particles. For vaccine development, particle production needs to be a reproducible, reliable process. Understanding the underlying processes in capsid size variation will help to produce particles of a defined capsid size presenting antigens consistent with intact virions. Next to vaccine production itself, this would be immensely beneficial for bio-/nano-technological approaches using viral particles as carriers or triggers for immunological reactions.
Collapse
|
22
|
Fernandez de la Mora J, Perez-Lorenzo LJ, Wick D. Singularly Narrow Viral Size and Mobility Standards from the 38.3 nm Chronic Bee Paralysis Virus and Its 17.5 nm Satellite. Anal Chem 2020; 92:13896-13903. [PMID: 32969651 DOI: 10.1021/acs.analchem.0c02687] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
The chronic bee paralysis virus (CBPV), extracted from sick or dead bees, was studied by mobility measurements via electrospray charge reduction with a differential mobility analyzer (DMA) of unusually high resolution. Three different particles are observed. The most abundant one contributes a mobility peak at 38.3 nm, approximately as expected for CBPV. The peak is very sharp in spite of the nonisometric nature of CBPV. We also observe a previously unreported weaker well-resolved shoulder 4.8% more mobile, perhaps due to empty (genome-free) particles. Another sharp peak appearing at approximately 17.51 nm is likely associated with the known icosahedral CBPV satellite (CBPVS). The 17.51 and 38.3 nm peaks offer size and mobility standards much narrower than previously reported at any size above 5 nm, with relative full peak width at half-maximum (FWHM) in mobility approaching 2% (∼1% in diameter). Slight but clear imperfections in the DMA response and the electrospraying process suggest that the real width of the viral mobility distribution is less than 2%.
Collapse
Affiliation(s)
- Juan Fernandez de la Mora
- Department of Mechanical Engineering and Materials Science, Yale University, New Haven, Connecticut 06520, United States
| | - Luis Javier Perez-Lorenzo
- Department of Mechanical Engineering and Materials Science, Yale University, New Haven, Connecticut 06520, United States
| | - David Wick
- BVS, Inc., Stevensville, Montana 59870, United States
| |
Collapse
|
23
|
Milewska A, Ner‐Kluza J, Dabrowska A, Bodzon‐Kulakowska A, Pyrc K, Suder P. MASS SPECTROMETRY IN VIROLOGICAL SCIENCES. MASS SPECTROMETRY REVIEWS 2020; 39:499-522. [PMID: 31876329 PMCID: PMC7228374 DOI: 10.1002/mas.21617] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2019] [Accepted: 12/15/2019] [Indexed: 05/24/2023]
Abstract
Virology, as a branch of the life sciences, discovered mass spectrometry (MS) to be the pivotal tool around two decades ago. The technique unveiled the complex network of interactions between the living world of pro- and eukaryotes and viruses, which delivered "a piece of bad news wrapped in protein" as defined by Peter Medawar, Nobel Prize Laureate, in 1960. However, MS is constantly evolving, and novel approaches allow for a better understanding of interactions in this micro- and nanoworld. Currently, we can investigate the interplay between the virus and the cell by analyzing proteomes, interactomes, virus-cell interactions, and search for the compounds that build viral structures. In addition, by using MS, it is possible to look at the cell from the broader perspective and determine the role of viral infection on the scale of the organism, for example, monitoring the crosstalk between infected tissues and the immune system. In such a way, MS became one of the major tools for the modern virology, allowing us to see the infection in the context of the whole cell or the organism. © 2019 John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Aleksandra Milewska
- Malopolska Centre of BiotechnologyJagiellonian UniversityGronostajowa 7A30‐387KrakowPoland
| | - Joanna Ner‐Kluza
- Department of Biochemistry and Neurobiology, Faculty of Materials Sciences and CeramicsAGH University of Science and TechnologyMickiewicza 30 Ave.30‐059KrakowPoland
| | - Agnieszka Dabrowska
- Malopolska Centre of BiotechnologyJagiellonian UniversityGronostajowa 7A30‐387KrakowPoland
- Faculty of Biochemistry, Biophysics and BiotechnologyJagiellonian UniversityGronostajowa 730‐387KrakowPoland
| | - Anna Bodzon‐Kulakowska
- Department of Biochemistry and Neurobiology, Faculty of Materials Sciences and CeramicsAGH University of Science and TechnologyMickiewicza 30 Ave.30‐059KrakowPoland
| | - Krzysztof Pyrc
- Malopolska Centre of BiotechnologyJagiellonian UniversityGronostajowa 7A30‐387KrakowPoland
| | - Piotr Suder
- Department of Biochemistry and Neurobiology, Faculty of Materials Sciences and CeramicsAGH University of Science and TechnologyMickiewicza 30 Ave.30‐059KrakowPoland
| |
Collapse
|
24
|
Weiss VU, Frank J, Piplits K, Szymanski WW, Allmaier G. Bipolar Corona Discharge-Based Charge Equilibration for Nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analysis of Bio- and Polymer Nanoparticles. Anal Chem 2020; 92:8665-8669. [PMID: 32519840 PMCID: PMC7467421 DOI: 10.1021/acs.analchem.0c01904] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
![]()
Separation
of polydisperse, single-charged analytes in the nanometer
size range in a high laminar sheath flow of particle-free ambient
air and a tunable electric field based on the respective particle
electrophoretic mobility diameter (EMD) can be achieved via gas-phase
electrophoresis. In order to transfer analytes from a volatile electrolyte
solution to the gas-phase as a single-charged species, a nano electrospray
(nES) process followed by drying of nanodroplets and charge conditioning
reaching Boltzmann charge equilibrium is a necessary prerequisite.
In the case of a so-called nES gas-phase electrophoretic mobility
molecular analyzer (nES GEMMA, also known as nES differential mobility
analyzer, nES DMA), charge equilibration is based on bionanoparticle
interaction with a bipolar atmosphere induced, e.g., by a radioactive
α-particle emitter like 210Po. It was the aim of
our investigation to examine whether such a radioactive source can
be easily replaced in the same nES housing by a nonradioactive one,
i.e., by an AC corona discharge unit. The latter would be significantly
easier to handle when compared to radioactive material in laboratory
day-to-day business, waste disposal, as well as regulatory confinements.
Indeed, we were able to combine a standard nES unit of our nES GEMMA
instrument with a commercially available AC corona discharge device
in a novel setup via an adapter. Our results show that this replacement
yields very good results for a number of chemically different nanoparticles,
an exemplary protein, a noncovalent protein complex, a virus-like
particle, a polymer, and a liposome sample, when compared to a 210Po based bipolar charge equilibration device.
Collapse
Affiliation(s)
- Victor U Weiss
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Johannes Frank
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Kurt Piplits
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | | | - Günter Allmaier
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| |
Collapse
|
25
|
Exploring the structure and dynamics of macromolecular complexes by native mass spectrometry. J Proteomics 2020; 222:103799. [DOI: 10.1016/j.jprot.2020.103799] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 03/23/2020] [Accepted: 04/25/2020] [Indexed: 12/15/2022]
|
26
|
Russier-Antoine I, Fakhouri H, Basu S, Bertorelle F, Dugourd P, Brevet PF, Velayudhan P, Thomas S, Kalarikkal N, Antoine R. Second harmonic scattering from mass characterized 2D graphene oxide sheets. Chem Commun (Camb) 2020; 56:3859-3862. [PMID: 32134076 DOI: 10.1039/d0cc00111b] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
In this communication, we report the second harmonic scattering from mass characterized 2D graphene oxide sheets dispersed in an aqueous suspension, in the femtosecond regime at 800 nm laser excitation. Charge-detection mass-spectrometry, performing at the single sheet level, allows for an exhaustive molar mass distribution and thus concentration for these 2D nanomaterials samples. The orientation-averaged hyperpolarizability value is (1.36 ± 0.15) × 10-25 esu as determined by the concentration-dependent harmonic scattering signal. In addition, the multi-photon excited fluorescence spectrum is characterized by a broad band in the visible range between 350 and 700 nm centered at about 500 nm.
Collapse
Affiliation(s)
- Isabelle Russier-Antoine
- Institut Lumière Matière UMR 5306, Université Claude Bernard Lyon 1, CNRS, Univ Lyon, F-69100 Villeurbanne, France.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Puglisi R, Boeri Erba E, Pastore A. A Guide to Native Mass Spectrometry to determine complex interactomes of molecular machines. FEBS J 2020; 287:2428-2439. [PMID: 32142206 PMCID: PMC8647915 DOI: 10.1111/febs.15281] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Revised: 02/01/2020] [Accepted: 03/04/2020] [Indexed: 01/17/2023]
Abstract
Native mass spectrometry is an emerging technique in biology that gives the possibility to study noncovalently bound complexes with high sensitivity and accuracy. It thus allows the characterization of macromolecular assemblies, assessing their mass and stoichiometries and mapping the interacting surfaces. In this review, we discuss the application of native mass spectrometry to dynamic molecular machines based on multiple weak interactions. In the study of these machines, it is crucial to understand which and under which conditions various complexes form at any time point. We focus on the specific example of the iron-sulfur cluster biogenesis machine because this is an archetype of a dynamic machine that requires very specific and demanding experimental conditions, such as anaerobicity and the need of retaining the fold of marginally folded proteins. We describe the advantages, challenges and current limitations of the technique by providing examples from our own experience and suggesting possible future solutions.
Collapse
Affiliation(s)
- Rita Puglisi
- UK Dementia Research Institute at the Wohl Institute of King's College London, UK
| | - Elisabetta Boeri Erba
- Univ. Grenoble Alpes, CEA, CNRS, Institut de Biologie Structurale (IBS), Grenoble, France
| | - Annalisa Pastore
- UK Dementia Research Institute at the Wohl Institute of King's College London, UK
| |
Collapse
|
28
|
Fernández-García J, Compton S, Wick D, Fernandez de la Mora J. Virus Size Analysis by Gas-Phase Mobility Measurements: Resolution Limits. Anal Chem 2019; 91:12962-12970. [PMID: 31509389 DOI: 10.1021/acs.analchem.9b03023] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Electrospraying (ES) dissolved viral particles, followed by charge reduction and size analysis with a differential mobility analyzer (DMA), offers a flexible size-analysis tool for small particles in solution. The technique relies on pioneering work by Kaufman and colleagues, commercialized by TSI, and often referred to as GEMMA. However, viral studies with TSI's GEMMA have suffered from limited resolving power, possibly because of imperfections in either the instrument (DMA or charge reduction) or the sample solution preparation. Here, we explore the limits of the resolution achievable by GEMMA, taking advantage of (i) cleaner charge reduction methods and (ii) DMAs of higher resolving power. Analysis of the literature provides indications that mobility peak widths (fwhm) of 2% or less may be achieved by combining careful sample preparation with improved instrumentation. Working with purified PP7 bacteriophage particles small enough to be classifiable by existing high-resolution DMAs, we confirm that fairly narrow viral mobility peaks may be obtained (relative full width at half-maximum fwhm <5%). Comparison of spectra of a given apian virus sample obtained with TSI's GEMMA and our improved instrumentation confirms that one critical limitation is the DMA. This is further verified by narrow peaks from murine parvovirus, norovirus, and encephalomyelitis virus samples, obtained in our improved GEMMA with little sample preparation, directly from infected cell cultures. Classification of purified large (60 nm) coliphage PR772 particles leads to broad peaks, due to both viral degradation and limited intrinsic resolution of the DMAs used to cover the range of such large particles. We conclude that improved DMAs suitable for high-resolution analysis of particles larger than 30 nm need to be developed to determine the intrinsic mobility width of viral particles.
Collapse
Affiliation(s)
- J Fernández-García
- Yale University , Department of Mechanical Engineering , New Haven , Connecticut 06520 , United States
| | - S Compton
- Yale University , School of Medicine , New Haven , Connecticut 06520 , United States
| | - D Wick
- BVS, Inc. , Stevensville , Montana 59870 , United States
| | - J Fernandez de la Mora
- Yale University , Department of Mechanical Engineering , New Haven , Connecticut 06520 , United States
| |
Collapse
|