1
|
Simmonds MJ, Meiselman HJ, Detterich JA. Blood Rheology and Hemodynamics: Still Illuminating after 20 Years. Semin Thromb Hemost 2024. [PMID: 38688304 DOI: 10.1055/s-0044-1786357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Affiliation(s)
- Michael J Simmonds
- Biorheology Research Laboratory, Griffith University, Gold Coast, Australia
| | - Herbert J Meiselman
- Department of Physiology and Neuroscience, Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Jon A Detterich
- Department of Physiology and Neuroscience, Keck School of Medicine, University of Southern California, Los Angeles, California
- Division of Cardiology, Children's Hospital of Los Angeles, Los Angeles, California
| |
Collapse
|
2
|
Suriany S, Liu H, Cheng AL, Wenby R, Patel N, Badran S, Meiselman HJ, Denton C, Coates TD, Wood JC, Detterich JA. Decreased erythrocyte aggregation in Glenn and Fontan: univentricular circulation as a rheologic disease model. Pediatr Res 2024; 95:1335-1345. [PMID: 38177250 DOI: 10.1038/s41390-023-02969-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/19/2023] [Accepted: 12/04/2023] [Indexed: 01/06/2024]
Abstract
BACKGROUND In the Fontan palliation for single ventricle heart disease (SVHD), pulmonary blood flow is non-pulsatile/passive, low velocity, and low shear, making viscous power loss a critical determinant of cardiac output. The rheologic properties of blood in SVHD patients are essential for understanding and modulating their limited cardiac output and they have not been systematically studied. We hypothesize that viscosity is decreased in single ventricle circulation. METHODS We evaluated whole blood viscosity, red blood cell (RBC) aggregation, and RBC deformability to evaluate changes in healthy children and SVHD patients. We altered suspending media to understand cellular and plasma differences contributing to rheologic differences. RESULTS Whole blood viscosity was similar between SVHD and healthy at their native hematocrits, while viscosity was lower at equivalent hematocrits for SVHD patients. RBC deformability is increased, and RBC aggregation is decreased in SVHD patients. Suspending SVHD RBCs in healthy plasma resulted in increased RBC aggregation and suspending healthy RBCs in SVHD plasma resulted in lower RBC aggregation. CONCLUSIONS Hematocrit corrected blood viscosity is lower in SVHD vs. healthy due to decreased RBC aggregation and higher RBC deformability, a viscous adaptation of blood in patients whose cardiac output is dependent on minimizing viscous power loss. IMPACT Patients with single ventricle circulation have decreased red blood cell aggregation and increased red blood cell deformability, both of which result in a decrease in blood viscosity across a large shear rate range. Since the unique Fontan circulation has very low-shear and low velocity flow in the pulmonary arteries, blood viscosity plays an increased role in vascular resistance, therefore this work is the first to describe a novel mechanism to target pulmonary vascular resistance as a modifiable risk factor. This is a novel, modifiable risk factor in this patient population.
Collapse
Affiliation(s)
- Silvie Suriany
- Division of Cardiology, Children's Hospital of Los Angeles, Los Angeles, CA, USA
| | - Honglei Liu
- Division of Cardiology, Children's Hospital of Los Angeles, Los Angeles, CA, USA
| | - Andrew L Cheng
- Division of Cardiology, Children's Hospital of Los Angeles, Los Angeles, CA, USA
| | - Rosalinda Wenby
- Department of Physiology and Neuroscience, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Neil Patel
- Division of Cardiology, Children's Hospital of Los Angeles, Los Angeles, CA, USA
| | - Sarah Badran
- Division of Pediatric and Congenital Cardiology, Helen Devos Children's Hospital at Spectrum Health, Grand Rapids, MI, USA
- Division of Cardiology, Department of Medicine, Michigan State University, East Lansing, MI, USA
| | - Herbert J Meiselman
- Department of Physiology and Neuroscience, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Christopher Denton
- Division of Hematology, Children's Hospital of Los Angeles, Los Angeles, CA, USA
| | - Thomas D Coates
- Division of Hematology, Children's Hospital of Los Angeles, Los Angeles, CA, USA
| | - John C Wood
- Division of Cardiology, Children's Hospital of Los Angeles, Los Angeles, CA, USA
| | - Jon A Detterich
- Division of Cardiology, Children's Hospital of Los Angeles, Los Angeles, CA, USA.
- Department of Physiology and Neuroscience, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.
| |
Collapse
|
3
|
Kong MW, Li YJ, Li J, Pei ZY, Xie YY, He GX. Down syndrome child with multiple heart diseases: A case report. World J Cardiol 2023; 15:615-622. [PMID: 38058402 PMCID: PMC10696207 DOI: 10.4330/wjc.v15.i11.615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 09/27/2023] [Accepted: 10/27/2023] [Indexed: 11/23/2023] Open
Abstract
BACKGROUND Down syndrome, also known as trisomy 21 syndrome, is commonly associated with congenital heart disease, and can often result in early formation of pulmonary hypertension. The development of pulmonary hypertension can result from factors such as intracardiac and macrovascular shunts, and upper airway obstruction or hypoplasia of lung tissue. Individuals with Down syndrome and congenital heart disease have a significantly lower average life expectancy, with surgical intervention being the most viable treatment option to improve longevity. CASE SUMMARY We report the case of a 13-year-old boy with Down syndrome presenting with atrial septal defect and patent ductus arteriosus along with severe pulmonary hypertension. The electrocardiogram shows sinus rhythm and right ventricular hypertrophy. The echocardiogram shows an atrial septal defect with interrupted echo in the interatrial septum, measuring 0.813 cm in length. The patient was initially refused to be offered surgical treatment by many hospitals due to the high surgical risk and pulmonary artery resistance. After discussing the patient's diagnosis and treatment options, we ultimately recommended surgical treatment. However, the patient and their family declined this recommendation and chose to be discharged. During the follow-up period of 6 mo, there were no significant improvements or deteriorations in the patient's condition. CONCLUSION In conclusion, this case highlights the challenges faced by individuals with Down syndrome and congenital heart disease complicated by severe pulmonary hypertension. Timely intervention and a multidisciplinary approach are crucial for improving prognosis and life expectancy. Further research is needed to enhance our understanding and develop effective interventions for this population.
Collapse
Affiliation(s)
- Mo-Wei Kong
- Department of Cardiology, Guiqian International General Hospital, Guiyang 550018, Guizhou Province, China
| | - Yi-Jing Li
- Department of Cardiology, Guiqian International General Hospital, Guiyang 550018, Guizhou Province, China
| | - Jun Li
- Department of Cardiology, Guiqian International General Hospital, Guiyang 550018, Guizhou Province, China.
| | - Zhen-Ying Pei
- Department of Cardiology, Guiqian International General Hospital, Guiyang 550018, Guizhou Province, China
| | - Yu-Yu Xie
- Department of Dermatology, Guiqian International General Hospital, Guiyang 550018, Guizhou Province, China
| | - Guo-Xiang He
- Department of Cardiology, Guiqian International General Hospital, Guiyang 550018, Guizhou Province, China
| |
Collapse
|
4
|
Ferrari MR, Schäfer M, Hunter KS, Di Maria MV. Central Venous Waveform Patterns in the Fontan Circulation Independently Contribute to the Prediction of Composite Survival. Pediatr Cardiol 2023:10.1007/s00246-023-03268-w. [PMID: 37773462 DOI: 10.1007/s00246-023-03268-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 08/07/2023] [Indexed: 10/01/2023]
Abstract
It is well appreciated that the Fontan circulation perturbs central venous hemodynamics, with elevated pressure being the clearest change associated with Fontan comorbidities, such as Fontan-associated liver disease (FALD) and protein-losing enteropathy (PLE). Our group has better quantity of these venous perturbations through single- and multi-location analyses of flow waveforms obtained from magnetic resonance imaging of Fontan patients. Here, we determine if such analyses, which yield principal components (PC) that describe flow features, are associated with Fontan survival. Patients with a Fontan circulation (N = 140) that underwent free-breathing and mechanically ventilated cardiac MRI were included in this study. Standard volumetric and functional hemodynamics, as well as flow analysis principal components, were subjected to univariate and bivariate Cox regression analyses to determine composite clinical outcome, including plastic bronchitis, PLE, and referral and receipt of transplant. Unsurprisingly, ventricular function measures of ejection fraction (EF; HR = 0.88, p < 0.0001), indexed end-systolic volume (ESVi; HR 1.02, p < 0.0001), and indexed end-diastolic volume (EDVi; HR = 1.02, p = 0.0007) were found as specific predictors of clinical events, with specificities uniformly > 0.75. Additionally a feature of IVC flow (PC2) indicating increased flow in systole was found as a highly sensitive predictor (HR = 0.851, p = 0.027, sensitivity 0.93). In bivariate prediction, combinations of ventricular function (EF, ESVi, EDVi) with this IVC flow feature yielded best overall prediction of composite outcome. This suggests that central venous waveform analysis relays additional information about Fontan patient survival and that coupling sensitive and specific measures in bivariate analysis is a useful approach for obtaining superior prediction of survival.
Collapse
Affiliation(s)
- Margaret R Ferrari
- Department of Bioengineering, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA
| | - Michal Schäfer
- Division of Cardiology, Heart Institute, Children's Hospital Colorado, University of Colorado Anschutz Medical Campus, 13123 East 16Th Ave, Aurora, CO, 80045, USA
| | - Kendall S Hunter
- Department of Bioengineering, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA
| | - Michael V Di Maria
- Division of Cardiology, Heart Institute, Children's Hospital Colorado, University of Colorado Anschutz Medical Campus, 13123 East 16Th Ave, Aurora, CO, 80045, USA.
| |
Collapse
|
5
|
Engineering Perspective on Cardiovascular Simulations of Fontan Hemodynamics: Where Do We Stand with a Look Towards Clinical Application. Cardiovasc Eng Technol 2021; 12:618-630. [PMID: 34114202 DOI: 10.1007/s13239-021-00541-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 04/30/2021] [Indexed: 01/02/2023]
Abstract
BACKGROUND Cardiovascular simulations for patients with single ventricles undergoing the Fontan procedure can assess patient-specific hemodynamics, explore surgical advances, and develop personalized strategies for surgery and patient care. These simulations have not yet been broadly accepted as a routine clinical tool owing to a number of limitations. Numerous approaches have been explored to seek innovative solutions for improving methodologies and eliminating these limitations. PURPOSE This article first reviews the current state of cardiovascular simulations of Fontan hemodynamics. Then, it will discuss the technical progress of Fontan simulations with the emphasis of its clinical impact, noting that substantial improvements have been made in the considerations of patient-specific anatomy, flow, and blood rheology. The article concludes with insights into potential future directions involving clinical validation, uncertainty quantification, and computational efficiency. The advancements in these aspects could promote the clinical usage of Fontan simulations, facilitating its integration into routine clinical practice.
Collapse
|
6
|
Non-Newtonian Effects on Patient-Specific Modeling of Fontan Hemodynamics. Ann Biomed Eng 2020; 48:2204-2217. [PMID: 32372365 DOI: 10.1007/s10439-020-02527-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Accepted: 04/29/2020] [Indexed: 12/15/2022]
Abstract
The Fontan procedure is a common palliative surgery for congenital single ventricle patients. In silico and in vitro patient-specific modeling approaches are widely utilized to investigate potential improvements of Fontan hemodynamics that are related to long-term complications. However, there is a lack of consensus regarding the use of non-Newtonian rheology, warranting a systematic investigation. This study conducted in silico patient-specific modeling for twelve Fontan patients, using a Newtonian and a non-Newtonian model for each patient. Differences were quantified by examining clinically relevant metrics: indexed power loss (iPL), indexed viscous dissipation rate (iVDR), hepatic flow distribution (HFD), and regions of low wall shear stress (AWSS). Four sets of "non-Newtonian importance factors" were calculated to explore their effectiveness in identifying the non-Newtonian effect. No statistical differences were observed in iPL, iVDR, and HFD between the two models at the population-level, but large inter-patient variations exist. Significant differences were detected regarding AWSS, and its correlations with non-Newtonian importance factors were discussed. Additionally, simulations using the non-Newtonian model were computationally faster than those using the Newtonian model. These findings distinguish good importance factors for identifying non-Newtonian rheology and encourage the use of a non-Newtonian model to assess Fontan hemodynamics.
Collapse
|
7
|
Härtel JA, Müller N, Herberg U, Breuer J, Bizjak DA, Bloch W, Grau M. Altered Hemorheology in Fontan Patients in Normoxia and After Acute Hypoxic Exercise. Front Physiol 2019; 10:1443. [PMID: 31824342 PMCID: PMC6883377 DOI: 10.3389/fphys.2019.01443] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Accepted: 11/08/2019] [Indexed: 12/02/2022] Open
Abstract
Background The Fontan circulation is a unique palliation procedure for several congenital heart defects. Impaired exercise capacity has previously been demonstrated in these patients and also a higher risk for cardiopulmonary mortality. Hemorheology was shown to affect cardiopulmonary capacity and in turn to be affected by regular exercise and hypoxia but none of these have been investigated in Fontan patients so far. The aim of this study was to detect general differences in hemorheology in normoxia as well as possible altered hemorheological responses to hypoxia exposure and hypoxic exercise between Fontan patients and healthy controls. Methods and Findings 26 Fontan patients and 20 healthy controls performed an acute exercise test (AET) on a bicycle ergometer under hypoxia with ambient 15.2% oxygen saturation (sO2). Blood samples were taken at rest in normoxia (T0), at rest in hypoxia (T1), after maximum exhaustion in hypoxia (T2), and after 50 min recovery in normoxia (T3). Hemorheological and blood parameters were investigated. Additionally, arterial stiffness was tested at T0. Red blood cell (RBC) deformability, NOx, erythropoietin (EPO) concentration, RBC count, hemoglobin (Hb) concentration and hematocrit (hct) were significantly increased in Fontan patients compared to controls. Same was observed for arterial stiffness. No changes were observed for RBC aggregation, fibrinogen concentration, free radical levels and vascular endothelial growth factor (VEGF). Hypoxia exposure did not change parameters, whereas exercise in hypoxia increased aggregation and hct significantly in both groups. Fontan patients showed significantly increased aggregation-disaggregation balance compared to controls. Conclusion Acute hypoxia exposure and exercise under hypoxia might have similar impact on hemorheology in Fontan patients and controls and was clinically well tolerated. Nevertheless, exercise alters aggregation and possibly hemodynamics which requires special attention in Fontan patients.
Collapse
Affiliation(s)
- Julian Alexander Härtel
- Department of Molecular and Cellular Sports Medicine, German Sport University Cologne, Cologne, Germany.,Department for Pediatric Cardiology, University Hospital Bonn, Bonn, Germany
| | - Nicole Müller
- Department for Pediatric Cardiology, University Hospital Bonn, Bonn, Germany
| | - Ulrike Herberg
- Department for Pediatric Cardiology, University Hospital Bonn, Bonn, Germany
| | - Johannes Breuer
- Department for Pediatric Cardiology, University Hospital Bonn, Bonn, Germany
| | - Daniel Alexander Bizjak
- Department of Molecular and Cellular Sports Medicine, German Sport University Cologne, Cologne, Germany
| | - Wilhelm Bloch
- Department of Molecular and Cellular Sports Medicine, German Sport University Cologne, Cologne, Germany
| | - Marijke Grau
- Department of Molecular and Cellular Sports Medicine, German Sport University Cologne, Cologne, Germany
| |
Collapse
|
8
|
Cheng AL, Wee CP, Pahlevan NM, Wood JC. A 4D flow MRI evaluation of the impact of shear-dependent fluid viscosity on in vitro Fontan circulation flow. Am J Physiol Heart Circ Physiol 2019; 317:H1243-H1253. [PMID: 31585044 DOI: 10.1152/ajpheart.00296.2019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The Fontan procedure for univentricular heart defects creates a nonphysiologic circulation where systemic venous blood drains directly into the pulmonary arteries, leading to multiorgan dysfunction secondary to chronic low-shear nonpulsatile pulmonary blood flow and central venous hypertension. Although blood viscosity increases exponentially in this low-shear environment, the role of shear-dependent ("non-Newtonian") blood viscosity in this pathophysiology is unclear. We studied three-dimensional (3D)-printed Fontan models in an in vitro flow loop with a Philips 3-T magnetic resonance imaging (MRI) scanner. A 4D flow phase-contrast sequence was used to acquire a time-varying 3D velocity field for each experimental condition. On the basis of blood viscosity of a cohort of patients who had undergone the Fontan procedure, it was decided to use 0.04% xanthan gum as a non-Newtonian blood analog; 45% glycerol was used as a Newtonian control fluid. MRI data were analyzed using GTFlow and MATLAB software. The primary outcome, power loss, was significantly higher with the Newtonian fluid [14.8 (13.3, 16.4) vs. 8.1 (6.4, 9.8)%, medians with 95% confidence interval, P < 0.0001]. The Newtonian fluid also demonstrated marginally higher right pulmonary artery flow, marginally lower shear stress, and a trend toward higher caval flow mixing. Outcomes were modulated by Fontan model complexity, cardiac output, and caval flow ratio. Vortexes, helical flow, and stagnant flow were more prevalent with the non-Newtonian fluid. Our data demonstrate that shear-dependent viscosity significantly alters qualitative flow patterns, power loss, pulmonary flow distribution, shear stress, and caval flow mixing in synthetic models of the Fontan circulation. Potential clinical implications include effects on exercise capacity, ventilation-perfusion matching, risk of pulmonary arteriovenous malformations, and risk of thromboembolism.NEW & NOTEWORTHY Although blood viscosity increases exponentially in low-shear environments, the role of shear-dependent ("non-Newtonian") blood viscosity in the pathophysiology of the low-shear Fontan circulation is unclear. We demonstrate that shear-dependent viscosity significantly alters qualitative flow patterns, power loss, pulmonary flow distribution, shear stress, and caval flow mixing in synthetic models of the Fontan circulation. Potential clinical implications include effects on exercise capacity, ventilation-perfusion matching, risk of pulmonary arteriovenous malformations, and risk of thromboembolism.
Collapse
Affiliation(s)
- Andrew L Cheng
- Division of Pediatric Cardiology, Children's Hospital Los Angeles, Los Angeles, California.,Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Choo Phei Wee
- Biostatistics Core, Children's Hospital Los Angeles, Los Angeles, California
| | - Niema M Pahlevan
- Keck School of Medicine, University of Southern California, Los Angeles, California.,Department of Aerospace and Mechanical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California
| | - John C Wood
- Division of Pediatric Cardiology, Children's Hospital Los Angeles, Los Angeles, California.,Keck School of Medicine, University of Southern California, Los Angeles, California
| |
Collapse
|
9
|
Impaired Blood Rheology in Pulmonary Arterial Hypertension. Heart Lung Circ 2019; 28:1067-1073. [DOI: 10.1016/j.hlc.2018.07.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 07/05/2018] [Accepted: 07/25/2018] [Indexed: 12/28/2022]
|
10
|
Wei ZA, Huddleston C, Trusty PM, Singh-Gryzbon S, Fogel MA, Veneziani A, Yoganathan AP. Analysis of Inlet Velocity Profiles in Numerical Assessment of Fontan Hemodynamics. Ann Biomed Eng 2019; 47:2258-2270. [PMID: 31236791 DOI: 10.1007/s10439-019-02307-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Accepted: 06/08/2019] [Indexed: 12/16/2022]
Abstract
Computational fluid dynamic (CFD) simulations are widely utilized to assess Fontan hemodynamics that are related to long-term complications. No previous studies have systemically investigated the effects of using different inlet velocity profiles in Fontan simulations. This study implements real, patient-specific velocity profiles for numerical assessment of Fontan hemodynamics using CFD simulations. Four additional, artificial velocity profiles were used for comparison: (1) flat, (2) parabolic, (3) Womersley, and (4) parabolic with inlet extensions [to develop flow before entering the total cavopulmonary connection (TCPC)]. The differences arising from the five velocity profiles, as well as discrepancies between the real and each of the artificial velocity profiles, were quantified by examining clinically important metrics in TCPC hemodynamics: power loss (PL), viscous dissipation rate (VDR), hepatic flow distribution, and regions of low wall shear stress. Statistically significant differences were observed in PL and VDR between simulations using real and flat velocity profiles, but differences between those using real velocity profiles and the other three artificial profiles did not reach statistical significance. These conclusions suggest that the artificial velocity profiles (2)-(4) are acceptable surrogates for real velocity profiles in Fontan simulations, but parabolic profiles are recommended because of their low computational demands and prevalent applicability.
Collapse
Affiliation(s)
- Zhenglun Alan Wei
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Suite 232, Atlanta, GA, 30313-2412, USA
| | - Connor Huddleston
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA, USA
| | - Phillip M Trusty
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Suite 232, Atlanta, GA, 30313-2412, USA
| | - Shelly Singh-Gryzbon
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Suite 232, Atlanta, GA, 30313-2412, USA
| | - Mark A Fogel
- Department of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Alessandro Veneziani
- Department of Mathematics, Department of Computer Science, Emory University, Atlanta, GA, USA
| | - Ajit P Yoganathan
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, 387 Technology Circle, Suite 232, Atlanta, GA, 30313-2412, USA.
| |
Collapse
|
11
|
Yu J, Han M, Geng J. Influence of propofol intravenous anesthesia on hemorheology, haemodynamics and immune function of colorectal carcinoma patients undergoing radical resection. Pak J Med Sci 2019; 35:780-785. [PMID: 31258594 PMCID: PMC6572957 DOI: 10.12669/pjms.35.3.590] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Objective To analyze the changes of hemorheology, haemodynamics and immune function of patients during propofol intravenous anesthesia in the radical resection of colorectal carcinoma and its significance. Methods The study included 112 patients who underwent radical resection of colorectal carcinoma in our hospital between August 2016 and December 2017, and they were divided into an observation group (N=56) and a control group (N=56) using random number table. Patients in the observation group were given propofol intravenous anesthesia, while patients in the control group received inhalation anesthesia of sevoflurane. Hemorheological and haemodynamical indexes were compared and analyzed before anesthesia (T0), 90 min after induction (T1), 150 min after induction (T2) and 30 min after entering post-anesthesia care unit (T3), and the changes of immune function before and after surgery was also observed. Results The whole blood viscosity under high, medium and low shear rates of the observation group declined significantly compared to that of the control group at T1, T2 and T3 (P<0.05). The heart rate (HR) and systolic pressure (SPB) of the observation group significantly decreased at T2 compared to those at T1 (P<0.05), but recovered to the level observed at T0 at T3. The diastolic blood pressure (DBP) of the two groups at T1, T2 and T3 was not significantly different with that at T0 (P>0.05). The levels of CD45RA+ and CD45RO+ of both groups had a significant decrease at the end of the surgery compared to before anesthesia (P<0.05); the levels of the observation group recovered at the postoperative 72nd h, and the differences with the levels before anesthesia had no statistical significance (P>0.05); the level of CD45RA+ of the control group also recovered at the postoperative 72nd h, but the difference with the level before anesthesia had no statistical significance (P>0.05); the level of CD45RO+ of the control group had a significant decrease, and the difference with the level before anesthesia was statistically significant (P<0.05). The level of CD45RA+/CD45RO+ of the observation group at the end of surgery and the postoperative 72nd h was not significantly different with those before anesthesia (P>0.05). The level of CD45RA+/CD45RO+ of the control group at the postoperative 72nd h showed a significant increase compared to before anesthesia (P<0.05). Conclusion Propofol intravenous anesthesia has a significant improvement effect on hemorheology before radical resection of colorectal carcinoma and has a small influence on haemodynamics. Moreover it is beneficial to the recovery of immune function. The therapy is worth promotion.
Collapse
Affiliation(s)
- Jianmin Yu
- Jianmin Yu, Department of Anesthesiology III, Binzhou People's Hospital, Shandong, 256610, China
| | - Mingfen Han
- Mingfen Han, Department of Anesthesiology III, Binzhou People's Hospital, Shandong, 256610, China
| | - Jun Geng
- Jun Geng, Inpatient Operating Rooms II, Binzhou People's Hospital, Shandong, 256610, China
| |
Collapse
|
12
|
Michel M, Zlamy M, Entenmann A, Pichler K, Scholl-Bürgi S, Karall D, Geiger R, Salvador C, Niederwanger C, Ohuchi H. Impact of the Fontan Operation on Organ Systems. Cardiovasc Hematol Disord Drug Targets 2019; 19:205-214. [PMID: 30747084 DOI: 10.2174/1871529x19666190211165124] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 01/09/2019] [Accepted: 01/29/2019] [Indexed: 02/06/2023]
Abstract
In patients having undergone the Fontan operation, besides the well discussed changes in the cardiac, pulmonary and gastrointestinal system, alterations of further organ systems including the hematologic, immunologic, endocrinological and metabolic are reported. As a medical adjunct to Fontan surgery, the systematic study of the central role of the liver as a metabolizing and synthesizing organ should allow for a better understanding of the pathomechanism underlying the typical problems in Fontan patients, and in this context, the profiling of endocrinological and metabolic patterns might offer a tool for the optimization of Fontan follow-up, targeted monitoring and specific adjunct treatment.
Collapse
Affiliation(s)
- Miriam Michel
- Department of Pediatrics III, Division of Cardiology, Pulmology, Allergology, and Cystic Fibrosis, Innsbruck Medical University, Anichstraße 35, 6020 Innsbruck, Austria
| | - Manuela Zlamy
- Department of Pediatrics I, Innsbruck Medical University, Anichstraße 35, 6020 Innsbruck, Austria
| | - Andreas Entenmann
- Department of Pediatrics I, Innsbruck Medical University, Anichstraße 35, 6020 Innsbruck, Austria
| | - Karin Pichler
- Department of Pediatrics, Vienna Medical University, Währinger Gürtel 16, 1090 Vienna, Austria
| | - Sabine Scholl-Bürgi
- Department of Pediatrics I, Innsbruck Medical University, Anichstraße 35, 6020 Innsbruck, Austria
| | - Daniela Karall
- Department of Pediatrics I, Innsbruck Medical University, Anichstraße 35, 6020 Innsbruck, Austria
| | - Ralf Geiger
- Department of Pediatrics III, Division of Cardiology, Pulmology, Allergology, and Cystic Fibrosis, Innsbruck Medical University, Anichstraße 35, 6020 Innsbruck, Austria
| | - Christina Salvador
- Department of Pediatrics I, Innsbruck Medical University, Anichstraße 35, 6020 Innsbruck, Austria
| | - Christian Niederwanger
- Department of Pediatrics I, Innsbruck Medical University, Anichstraße 35, 6020 Innsbruck, Austria
| | - Hideo Ohuchi
- Department for Pediatric Cardiology, National Cerebral and Cardiovascular Center, 5-7-1 Fujishiro-dai, Suita, Osaka 565-8565, Japan
| |
Collapse
|
13
|
Sinha L, Yerebakan C. The first integrated aortic turbine venous-assist system is born. J Thorac Cardiovasc Surg 2018; 156:304-305. [PMID: 29753509 DOI: 10.1016/j.jtcvs.2018.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 04/06/2018] [Indexed: 11/19/2022]
Affiliation(s)
- Lok Sinha
- Division of Cardiovascular Surgery, Children's National Heart Institute, Children's National Health System, The George Washington University School of Medicine and Health Sciences, Washington, DC
| | - Can Yerebakan
- Division of Cardiovascular Surgery, Children's National Heart Institute, Children's National Health System, The George Washington University School of Medicine and Health Sciences, Washington, DC.
| |
Collapse
|
14
|
Cheng AL, Pahlevan NM, Rinderknecht DG, Wood JC, Gharib M. Experimental Investigation of the Effect of Non-Newtonian Behavior of Blood Flow in the Fontan Circulation. EUROPEAN JOURNAL OF MECHANICS. B, FLUIDS 2018; 68:184-192. [PMID: 29736127 PMCID: PMC5935448 DOI: 10.1016/j.euromechflu.2017.12.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The Fontan procedure for univentricular heart defects creates a unique circulation where all pulmonary blood flow is passively supplied directly from systemic veins. Computational simulations, aimed at optimizing the surgery, have assumed blood to be a Newtonian fluid without evaluating the potential error introduced by this assumption. We compared flow behavior between a non-Newtonian blood analog (0.04% xanthan gum) and a control Newtonian fluid (45% glycerol) in a simplified model of the Fontan circulation. Particle image velocimetry was used to examine flow behavior at two different cardiac outputs and two caval blood flow distributions. Pressure and flow rates were measured at each inlet and outlet. Velocity, shear strain, and shear stress maps were derived from velocity data. Power loss was calculated from pressure, flow, and velocity data. Power loss was increased in all test conditions with xanthan gum vs. glycerol (mean 10±2.9% vs. 5.6±1.3%, p=0.032). Pulmonary blood flow distribution differed in all conditions, more so at low cardiac output. Caval blood flow mixing patterns and shear stress were also qualitatively different between the solutions in all conditions. We conclude that assuming blood to be a Newtonian fluid introduces considerable error into simulations of the Fontan circulation, where low-shear flow predominates.
Collapse
Affiliation(s)
- Andrew L. Cheng
- Division of Pediatric Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Niema M. Pahlevan
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, USA
- Huntington Medical Research Institutes, Pasadena, CA, USA
| | - Derek G. Rinderknecht
- Graduate Aerospace Laboratories, California Institute of Technology, Pasadena, CA, USA
| | - John C. Wood
- Division of Pediatric Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Morteza Gharib
- Graduate Aerospace Laboratories, California Institute of Technology, Pasadena, CA, USA
- Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| |
Collapse
|
15
|
The Advantages of Viscous Dissipation Rate over Simplified Power Loss as a Fontan Hemodynamic Metric. Ann Biomed Eng 2017; 46:404-416. [PMID: 29094292 DOI: 10.1007/s10439-017-1950-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Accepted: 10/20/2017] [Indexed: 12/12/2022]
Abstract
Flow efficiency through the Fontan connection is an important factor related to patient outcomes. It can be quantified using either a simplified power loss or a viscous dissipation rate metric. Though practically equivalent in simplified Fontan circulation models, these metrics are not identical. Investigation is needed to evaluate the advantages and disadvantages of these metrics for their use in in vivo or more physiologically-accurate Fontan modeling. Thus, simplified power loss and viscous dissipation rate are compared theoretically, computationally, and statistically in this study. Theoretical analysis was employed to assess the assumptions made for each metric and its clinical calculability. Computational simulations were then performed to obtain these two metrics. The results showed that apparent simplified power loss was always greater than the viscous dissipation rate for each patient. This discrepancy can be attributed to the assumptions derived in theoretical analysis. Their effects were also deliberately quantified in this study. Furthermore, statistical analysis was conducted to assess the correlation between the two metrics. Viscous dissipation rate and its indexed quantity show significant, strong, linear correlation to simplified power loss and its indexed quantity (p < 0.001, r > 0.99) under certain assumptions. In conclusion, viscous dissipation rate was found to be more advantageous than simplified power loss as a hemodynamic metric because of its lack of limiting assumptions and calculability in the clinic. Moreover, in addition to providing a time-averaged bulk measurement like simplified power loss, viscous dissipation rate has spatial distribution contours and time-resolved values that may provide additional clinical insight. Finally, viscous dissipation rate could maintain the relationship between Fontan connection flow efficiency and patient outcomes found in previous studies. Consequently, future Fontan hemodynamic studies should calculate both simplified power loss and viscous dissipation rate to maintain ties to previous studies, but also provide the most accurate measure of flow efficiency. Additional attention should be paid to the assumptions required for each metric.
Collapse
|
16
|
Jung JH, Chae YJ, Lee DH, Cho YI, Ko MM, Park SK, Kim W. Changes in whole blood viscosity during hemodialysis and mortality in patients with end-stage renal disease. Clin Hemorheol Microcirc 2017; 65:285-297. [DOI: 10.3233/ch-16183] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Jong Hwan Jung
- Department of Internal Medicine, Divsion of Nephrology, Wonkwang University College of Medicine, Iksan, Republic of Korea
| | - Yoon Jung Chae
- College of Nursing, Chonbuk National University, Jeonju, Republic of Korea
| | - Dong Hwan Lee
- Department of Mechanical Design Engineering, Engineering College, Chonbuk National University, Jeonju, Republic of Korea
| | - Young I. Cho
- Department of Mechanical Engineering and Mechanics, Drexel University, Philadelphia, Pennsylvania, USA
| | - Mi Mi Ko
- KM Fundamental Research Division, Korea Institute of Oriental Medicine, Daejeon, Republic of Korea
| | - Sung Kwang Park
- Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Chonbuk National University Medical School, Jeonju, Republic of Korea
| | - Won Kim
- Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Chonbuk National University Medical School, Jeonju, Republic of Korea
| |
Collapse
|