1
|
PEI-Mediated Assembly of Fe 3O 4 onto SiO 2-Encapsulated CsPbBr 3 for Highly Sensitive Fluorescent Lateral Flow Immunoassay. Anal Chem 2024; 96:6065-6071. [PMID: 38569047 DOI: 10.1021/acs.analchem.4c00648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2024]
Abstract
The conventional lateral flow immunoassay (LFIA) method using colloidal gold nanoparticles (Au NPs) as labeling agents faces two inherent limitations, including restricted sensitivity and poor quantitative capability, which impede early viral infection detection. Herein, we designed and synthesized CsPbBr3 perovskite quantum dot-based composite nanoparticles, CsPbBr3@SiO2@Fe3O4 (CSF), which integrated fluorescence detection and magnetic enrichment properties into LFIA technology and achieved rapid, sensitive, and convenient quantitative detection of the SARS-CoV-2 virus N protein. In this study, CsPbBr3 served as a high-quantum-yield fluorescent signaling probe, while SiO2 significantly enhanced the stability and biomodifiability of CsPbBr3. Importantly, the SiO2 shell shows relatively low absorption or scattering toward fluorescence, maintaining a quantum yield of up to 74.4% in CsPbBr3@SiO2. Assembly of Fe3O4 nanoparticles mediated by PEI further enhanced the method's sensitivity and reduced matrix interference through magnetic enrichment. Consequently, the method achieved a fluorescent detection range of 1 × 102 to 5 × 106 pg·mL-1 after magnetic enrichment, with a limit of detection (LOD) of 58.8 pg·mL-1, representing a 13.3-fold improvement compared to nonenriched samples (7.58 × 102 pg·mL-1) and a 2-orders-of-magnitude improvement over commercial colloidal gold kits. Furthermore, the method exhibited 80% positive and 100% negative detection rates in clinical samples. This approach holds promise for on-site diagnosis, home-based quantitative tests, and disease procession evaluation.
Collapse
|
2
|
Rapid and sensitive detection of Salmonella in agro-Food and environmental samples: A review of advances in rapid tests and biosensors. J Microbiol Methods 2024; 219:106897. [PMID: 38342249 DOI: 10.1016/j.mimet.2024.106897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 02/07/2024] [Accepted: 02/08/2024] [Indexed: 02/13/2024]
Abstract
Salmonella is as an intracellular bacterium, causing many human fatalities when the host-specific serotypes reach the host gastrointestinal tract. Nontyphoidal Salmonella are responsible for numerous foodborne outbreaks and product recalls worldwide whereas typhoidal Salmonella are responsible for Typhoid fever cases in developing countries. Yet, Salmonella-related foodborne disease outbreaks through its food and water contaminations have urged the advancement of rapid and sensitive Salmonella-detecting methods for public health protection. While conventional detection methods are time-consuming and ineffective for monitoring foodstuffs with short shelf lives, advances in microbiology, molecular biology and biosensor methods have hastened the detection. Here, the review discusses Salmonella pathogenic mechanisms and its detection technology advancements (fundamental concepts, features, implementations, efficiency, benefits, limitations and prospects). The time-efficiency of each rapid test method is discussed in relation to their limit of detections (LODs) and time required from sample enrichment to final data analysis. Importantly, the matrix effects (LODs and sample enrichments) were compared within the methods to potentially speculate Salmonella detection from environmental, clinical or food matrices using certain techniques. Although biotechnological advancements have led to various time-efficient Salmonella-detecting techniques, one should consider the usage of sophisticated equipment to run the analysis by moderately to highly trained personnel. Ultimately, a fast, accurate Salmonella screening that is readily executed by untrained personnels from various matrices, is desired for public health procurement.
Collapse
|
3
|
Dual-Toehold-Probe-Mediated Exonuclease-III-Assisted Signal Recycles Integrated with CHA for Detection of mecA Gene Using a Personal Glucose Meter in Skin and Soft Tissue Infection. J Microbiol Biotechnol 2023; 33:1692-1697. [PMID: 37734933 PMCID: PMC10772588 DOI: 10.4014/jmb.2306.06037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 08/04/2023] [Accepted: 08/10/2023] [Indexed: 09/23/2023]
Abstract
Staphylococcus aureus integrated with mecA gene, which codes for penicillin-binding protein 2a, is resistant to all penicillins and other beta-lactam antibiotics, resulting in poor treatment expectations in skin and soft tissue infections. The development of a simple, sensitive and portable biosensor for mecA gene analysis in S. aureus is urgently needed. Herein, we propose a dual-toehold-probe (sensing probe)-mediated exonuclease-III (Exo-III)-assisted signal recycling for portable detection of the mecA gene in S. aureus. When the target mecA gene is present, it hybridizes with the sensing probe, initiating Exo III-assisted dual signal recycles, which in turn release numerous "3" sequences. The released "3" sequences initiate catalytic hairpin amplification, resulting in the fixation of a sucrase-labeled H2 probe on the surface of magnetic beads (MBs). After magnet-based enrichment of an MB-H1-H2-sucrase complex and removal of a liquid supernatant containing free sucrase, the complex is then used to catalyze sucrose to glucose, which can be quantitatively detected by a personal glucose meter. With a limit of detection of 4.36 fM for mecA gene, the developed strategy exhibits high sensitivity. In addition, good selectivity and anti-interference capability were also attained with this method, making it promising for antibiotic tolerance analysis at the point-of-care.
Collapse
|
4
|
Recent Advances in Electrochemical Biosensors for the Detection of Foodborne Pathogens: Current Perspective and Challenges. Foods 2023; 12:2795. [PMID: 37509887 PMCID: PMC10379338 DOI: 10.3390/foods12142795] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 07/21/2023] [Accepted: 07/22/2023] [Indexed: 07/30/2023] Open
Abstract
Foodborne pathogens cause many diseases and significantly impact human health and the economy. Foodborne pathogens mainly include Salmonella spp., Escherichia coli, Staphylococcus aureus, Shigella spp., Campylobacter spp. and Listeria monocytogenes, which are present in agricultural products, dairy products, animal-derived foods and the environment. Various pathogens in many different types of food and water can cause potentially life-threatening diseases and develop resistance to various types of antibiotics. The harm of foodborne pathogens is increasing, necessitating effective and efficient methods for early monitoring and detection. Traditional methods, such as real-time polymerase chain reaction (RT-PCR), enzyme-linked immunosorbent assay (ELISA) and culture plate, are time-consuming, labour-intensive and expensive and cannot satisfy the demands of rapid food testing. Therefore, new fast detection methods are urgently needed. Electrochemical biosensors provide consumer-friendly methods to quickly detect foodborne pathogens in food and the environment and achieve extensive accuracy and reproducible results. In this paper, by focusing on various mechanisms of electrochemical transducers, we present a comprehensive overview of electrochemical biosensors for the detection of foodborne pathogens. Furthermore, the review introduces the hazards of foodborne pathogens, risk analysis methods and measures of control. Finally, the review also emphasizes the recent research progress and solutions regarding the use of electrochemical biosensors to detect foodborne pathogens in food and the environment, evaluates limitations and challenges experienced during the development of biosensors to detect foodborne pathogens and discusses future possibilities.
Collapse
|
5
|
Filtration assisted pretreatment for rapid enrichment and accurate detection of Salmonella in vegetables. FOOD SCIENCE AND HUMAN WELLNESS 2023. [DOI: 10.1016/j.fshw.2022.10.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
6
|
Amperometric Biosensor for Quantitative Measurement Using Sandwich Immunoassays. BIOSENSORS 2023; 13:bios13050519. [PMID: 37232880 DOI: 10.3390/bios13050519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/02/2023] [Accepted: 05/03/2023] [Indexed: 05/27/2023]
Abstract
State-of-the-art clinical detection methods typically involve standard immunoassay methods, requiring specialized equipment and trained personnel. This impedes their use in the Point-of-Care (PoC) environment, where ease of operation, portability, and cost efficiency are prioritized. Small, robust electrochemical biosensors provide a means with which to analyze biomarkers in biological fluids in PoC environments. Optimized sensing surfaces, immobilization strategies, and efficient reporter systems are key to improving biosensor detection systems. The signal transduction and general performance of electrochemical sensors are determined by surface properties that link the sensing element to the biological sample. We analyzed the surface characteristics of screen-printed and thin-film electrodes using scanning electron microscopy and atomic force microscopy. An enzyme-linked immunosorbent assay (ELISA) was adapted for use in an electrochemical sensor. The robustness and reproducibility of the developed electrochemical immunosensor were investigated by detecting Neutrophil Gelatinase-Associated Lipocalin (NGAL) in urine. The sensor showed a detection limit of 1 ng/mL, a linear range of 3.5-80 ng/mL, and a CV% of 8%. The results demonstrate that the developed platform technology is suitable for immunoassay-based sensors on either screen-printed or thin-film gold electrodes.
Collapse
|
7
|
Advanced nano biosensors for rapid detection of zoonotic bacteria. Biotechnol Bioeng 2023; 120:41-56. [PMID: 36253878 DOI: 10.1002/bit.28266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 09/09/2022] [Accepted: 10/11/2022] [Indexed: 11/07/2022]
Abstract
An infectious disease that is transmitted from animals to humans and vice-versa is called zoonosis. Bacterial zoonotic diseases can re-emerge after they have been eradicated or controlled and are among the world's major health problems which inflict tremendous burden on healthcare systems. The first step to encounter such illnesses can be early and precise detection of bacterial pathogens to further prevent the following losses due to their infections. Although conventional methods for diagnosing pathogens, including culture-based, polymerase chain reaction-based, and immunological-based techniques, benefit from their advantages, they also have their own drawbacks, for example, taking long time to provide results, and requiring laborious work, expensive materials, and special equipment in certain conditions. Consequently, there is a greater tendency to introduce simple, innovative, quicker, accurate, and low-cost detection methods to effectively characterize the causative agents of infectious diseases. Biosensors, therefore, seem to practically be one of those novel promising diagnostic tools on this aim. These are effective and reliable elements with high sensitivity and specificity, that their usability can even be improved in medical diagnostic systems when empowered by nanoparticles. In the present review, recent advances in the development of several bio and nano biosensors, for rapid detection of zoonotic bacteria, have been discussed in details.
Collapse
|
8
|
Aptamer-Based Electrochemical Biosensors for the Detection of Salmonella: A Scoping Review. Diagnostics (Basel) 2022; 12:diagnostics12123186. [PMID: 36553193 PMCID: PMC9777869 DOI: 10.3390/diagnostics12123186] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 11/28/2022] [Accepted: 12/14/2022] [Indexed: 12/23/2022] Open
Abstract
The development of rapid, accurate, and efficient detection methods for Salmonella can significantly control the outbreak of salmonellosis that threatens global public health. Despite the high sensitivity and specificity of the microbiological, nucleic-acid, and immunological-based methods, they are impractical for detecting samples outside of the laboratory due to the requirement for skilled individuals and sophisticated bench-top equipment. Ideally, an electrochemical biosensor could overcome the limitations of these detection methods since it offers simplicity for the detection process, on-site quantitative analysis, rapid detection time, high sensitivity, and portability. The present scoping review aims to assess the current trends in electrochemical aptasensors to detect and quantify Salmonella. This review was conducted according to the latest Preferred Reporting Items for Systematic review and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines. A literature search was performed using aptamer and Salmonella keywords in three databases: PubMed, Scopus, and Springer. Studies on electrochemical aptasensors for detecting Salmonella published between January 2014 and January 2022 were retrieved. Of the 787 studies recorded in the search, 29 studies were screened for eligibility, and 15 studies that met the inclusion criteria were retrieved for this review. Information on the Salmonella serovars, targets, samples, sensor specification, platform technologies for fabrication, electrochemical detection methods, limit of detection (LoD), and detection time was discussed to evaluate the effectiveness and limitations of the developed electrochemical aptasensor platform for the detection of Salmonella. The reported electrochemical aptasensors were mainly developed to detect Salmonella enterica Typhimurium in chicken meat samples. Most of the developed electrochemical aptasensors were fabricated using conventional electrodes (13 studies) rather than screen-printed electrodes (SPEs) (two studies). The developed aptasensors showed LoD ranges from 550 CFU/mL to as low as 1 CFU/mL within 5 min to 240 min of detection time. The promising detection performance of the electrochemical aptasensor highlights its potential as an excellent alternative to the existing detection methods. Nonetheless, more research is required to determine the sensitivity and specificity of the electrochemical sensing platform for Salmonella detection, particularly in human clinical samples, to enable their future use in clinical practice.
Collapse
|
9
|
Review of Electrochemical Biosensors for Food Safety Detection. BIOSENSORS 2022; 12:bios12110959. [PMID: 36354467 PMCID: PMC9688552 DOI: 10.3390/bios12110959] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/28/2022] [Accepted: 10/31/2022] [Indexed: 05/30/2023]
Abstract
Food safety issues are directly related to people's quality of life, so there is a need to develop efficient and reliable food contaminants' detection devices to ensure the safety and quality of food. Electrochemical biosensors have the significant advantages of miniaturization, low cost, high sensitivity, high selectivity, rapid detection, and low detection limits using small amounts of samples, which are expected to enable on-site analysis of food products. In this paper, the latest electrochemical biosensors for the detection of biological contaminants, chemical contaminants, and genetically modified crops are reviewed based on the analytes of interest, electrode materials and modification methods, electrochemical methods, and detection limits. This review shows that electrochemical biosensors are poised to provide miniaturized, specific, selective, fast detection, and high-sensitivity sensor platforms for food safety.
Collapse
|
10
|
A Novel Prototype Biosensor Array Electrode System for Detecting the Bacterial Pathogen Salmonella typhimurium. BIOSENSORS 2022; 12:389. [PMID: 35735537 PMCID: PMC9221460 DOI: 10.3390/bios12060389] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 05/26/2022] [Accepted: 06/02/2022] [Indexed: 06/15/2023]
Abstract
Salmonellosis caused by Salmonella sp. has long been reported all over the world. Despite the availability of various diagnostic methods, easy and effective detection systems are still required. This report describes a dialysis membrane electrode interface disc with immobilized specific antibodies to capture antigenic Salmonella cells. The interaction of a specific Salmonella antigen with a mouse anti-Salmonella monoclonal antibody complexed to rabbit anti-mouse secondary antibody conjugated with HRP and the substrate o-aminophenol resulted in a response signal output current measured using two electrode systems (cadmium reference electrode and glassy carbon working electrode) and an agilent HP34401A 6.5 digital multimeter without a potentiostat or applied potential input. A maximum response signal output current was recorded for various concentrations of Salmonella viz., 3, 30, 300, 3000, 30,000 and 300,000 cells. The biosensor has a detection limit of three cells, which is very sensitive when compared with other detection sensors. Little non-specific response was observed using Streptococcus, Vibrio, and Pseudomonas sp. The maximum response signal output current for a dialysis membrane electrode interface disc was greater than that for gelatin, collagen, and agarose. The device and technique have a range of biological applications. This novel detection system has great potential for future development and application in surveillance for microbial pathogens.
Collapse
|
11
|
OUP accepted manuscript. J AOAC Int 2022; 105:1092-1104. [DOI: 10.1093/jaoacint/qsac008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 12/19/2021] [Accepted: 01/13/2022] [Indexed: 11/13/2022]
|
12
|
Effect of time and storage condition on the performance of an electrochemical immunosensor for Salmonella. FOOD SCIENCE AND TECHNOLOGY 2022. [DOI: 10.1590/fst.91621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
13
|
Advancement in Salmonella Detection Methods: From Conventional to Electrochemical-Based Sensing Detection. BIOSENSORS-BASEL 2021; 11:bios11090346. [PMID: 34562936 PMCID: PMC8468554 DOI: 10.3390/bios11090346] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 09/06/2021] [Accepted: 09/09/2021] [Indexed: 02/07/2023]
Abstract
Large-scale food-borne outbreaks caused by Salmonella are rarely seen nowadays, thanks to the advanced nature of the medical system. However, small, localised outbreaks in certain regions still exist and could possess a huge threat to the public health if eradication measure is not initiated. This review discusses the progress of Salmonella detection approaches covering their basic principles, characteristics, applications, and performances. Conventional Salmonella detection is usually performed using a culture-based method, which is time-consuming, labour intensive, and unsuitable for on-site testing and high-throughput analysis. To date, there are many detection methods with a unique detection system available for Salmonella detection utilising immunological-based techniques, molecular-based techniques, mass spectrometry, spectroscopy, optical phenotyping, and biosensor methods. The electrochemical biosensor has growing interest in Salmonella detection mainly due to its excellent sensitivity, rapidity, and portability. The use of a highly specific bioreceptor, such as aptamers, and the application of nanomaterials are contributing factors to these excellent characteristics. Furthermore, insight on the types of biorecognition elements, the principles of electrochemical transduction elements, and the miniaturisation potential of electrochemical biosensors are discussed.
Collapse
|
14
|
Performance of an amperometric immunosensor assembled on carboxymethylated cashew gum for Salmonella detection. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106268] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
15
|
Modernization of Control of Pathogenic Micro-Organisms in the Food-Chain Requires a Durable Role for Immunoaffinity-Based Detection Methodology-A Review. Foods 2021; 10:foods10040832. [PMID: 33920486 PMCID: PMC8069916 DOI: 10.3390/foods10040832] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 03/28/2021] [Accepted: 04/02/2021] [Indexed: 01/03/2023] Open
Abstract
Food microbiology is deluged by a vastly growing plethora of analytical methods. This review endeavors to color the context into which methodology has to fit and underlines the importance of sampling and sample treatment. The context is that the highest risk of food contamination is through the animal and human fecal route with a majority of foodborne infections originating from sources in mass and domestic kitchens at the end of the food-chain. Containment requires easy-to-use, failsafe, single-use tests giving an overall risk score in situ. Conversely, progressive food-safety systems are relying increasingly on early assessment of batches and groups involving risk-based sampling, monitoring environment and herd/flock health status, and (historic) food-chain information. Accordingly, responsible field laboratories prefer specificity, multi-analyte, and high-throughput procedures. Under certain etiological and epidemiological circumstances, indirect antigen immunoaffinity assays outperform the diagnostic sensitivity and diagnostic specificity of e.g., nucleic acid sequence-based assays. The current bulk of testing involves therefore ante- and post-mortem probing of humoral response to several pathogens. In this review, the inclusion of immunoglobulins against additional invasive micro-organisms indicating the level of hygiene and ergo public health risks in tests is advocated. Immunomagnetic separation, immunochromatography, immunosensor, microsphere array, lab-on-a-chip/disc platforms increasingly in combination with nanotechnologies, are discussed. The heuristic development of portable and ambulant microfluidic devices is intriguing and promising. Tant pis, many new platforms seem unattainable as the industry standard. Comparability of results with those of reference methods hinders the implementation of new technologies. Whatever the scientific and technological excellence and incentives, the decision-maker determines this implementation after weighing mainly costs and business risks.
Collapse
|
16
|
Perspectives for Recognition and Rapid Detection of Foodborne Pathogenic Bacteria Based on Electrochemical Sensors. EFOOD 2021. [DOI: 10.2991/efood.k.210621.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
17
|
An aptamer biosensor based dual signal amplification system for the detection of salmonella typhimurium. Anal Biochem 2020; 615:114050. [PMID: 33285125 DOI: 10.1016/j.ab.2020.114050] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 11/14/2020] [Accepted: 11/24/2020] [Indexed: 12/27/2022]
Abstract
Salmonella, a typical foodborne pathogen, always seriously threatens the health and even life of both humans and animals. However, highly sensitive and fast quantitative methods for its detection are remaining to be challenged. Herein, we presented an efficient method with dual signal amplification strategy by combining immune hybridization chain reaction (HCR) with surface enhanced Raman scattering (SERS) to high sensitively detect Salmonella typhimurium in food. After sample preparation, S. typhimurium were specifically captured by immunomagnetic beads (IMBs), then aptamers and hairpin-probes were added to trigger HCR to form nicked dsDNA, finally 4',6-Diamidino-2-phenylindole dihydrochloride (DAPI) was incubated with HCR products and then the whole system was mixed with AgNP colloid to detect the SERS intensity at 1610 cm-1. As a result, a good linear relationship was achieved between SERS intensities and corresponding concentrations of S. typhimurium ranging from 10 to 105 CFU/mL, with a limit of detection (LOD) of 6 CFU/mL in 3.5 h. The proposed method has been successfully applied to capture and detect the S. typhimurium in spiked milk samples, and the results were consistent with those of the traditional plate counting method. The method, with combination of HCR and SERS, achieves double amplification of the detection signal and significantly improves the detection sensitivity of S. typhimurium. And it also shows good application potential for the highly sensitive detection of other contaminants in food.
Collapse
|
18
|
An on-site, highly specific immunosensor for Escherichia coli detection in field milk samples from mastitis-affected dairy cattle. Biosens Bioelectron 2020; 165:112366. [DOI: 10.1016/j.bios.2020.112366] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 05/16/2020] [Accepted: 06/04/2020] [Indexed: 12/16/2022]
|
19
|
Designing a magnetic inductive micro-electrode for virus monitoring: modelling and feasibility for hepatitis B virus. Mikrochim Acta 2020; 187:463. [PMID: 32686021 DOI: 10.1007/s00604-020-04429-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 07/06/2020] [Indexed: 12/13/2022]
Abstract
A simple model is designed for an inductive immunosensor in which the magnetic particles are attached to the bioreceptors to form a sandwich on the surface of an inductor. The inductor consists of a coil covered on a silicon oxide wafer. The coil comprises 250 turns of a planar gold wire, which is approximately 200 nm thick and 392 mm long, placed in a circle with a diameter of 2 mm. The model is well characterised by controlling the geometrical and electrical parameters and also the permeability of the magnetic material. To evaluate the feasibility of the model for virus monitoring, a novel inductive immunosensor is designed and for the first time applied for the detection of hepatitis B surface antigen (HBsAg). At first, Fab' segment of primary anti-HBsAg is immobilised on the coil. Then, the coil is exposed to HBsAg and the complex is introduced to a secondary antibody conjugated with magnetic particles to form an immune-sandwich. Finally, the influence of magnetic particles on the coil inductance is recorded and used as a signal for HBsAg detection. The magnetic inductive immunosensor showed specific responses toward HBsAg with the detection limit of 1 ng mL-1, linear range of 1 to 200 ng mL-1, and a sensitivity of 6 × 10-4 mL ng-1. The experimental results showed a very good agreement with simulation data indicating the compatibility of sensor sensitivity to the expected theoretical values. Graphical abstract.
Collapse
|
20
|
|
21
|
Reduced Graphene Oxide-Based Impedimetric Immunosensor for Detection of Enterotoxin A in Milk Samples. MATERIALS 2020; 13:ma13071751. [PMID: 32290030 PMCID: PMC7178653 DOI: 10.3390/ma13071751] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 03/27/2020] [Accepted: 04/07/2020] [Indexed: 02/07/2023]
Abstract
A simple, cheap, and less aggressive immobilization procedure for biomolecules using reduced graphene oxide (rGO) was employed to prepare an impedimetric immunosensor for detection of staphylococcal enterotoxin A (SEA) from Staphylococcus aureus in milk samples. The scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy (EIS) were used to monitor the single steps of the electrode assembly process. The glassy carbon (GC)/rGO platform detected the antigen-antibody binding procedures of SEA with concentrations of 0.5 to 3.5 mg L−1 via impedance changes in a low frequency range. The impedimetric immunosensor was successfully applied for the determination of SEA in milk samples.
Collapse
|
22
|
Discrimination of hazardous bacteria with combination laser-induced breakdown spectroscopy and statistical methods. APPLIED OPTICS 2020; 59:1329-1337. [PMID: 32225392 DOI: 10.1364/ao.379136] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Accepted: 12/21/2019] [Indexed: 06/10/2023]
Abstract
Real-time biohazard detectors must be developed to facilitate the rapid implementation of appropriate protective measures against foodborne pathogens. Laser-induced breakdown spectroscopy (LIBS) is a promising technique for the real-time detection of hazardous bacteria (HB) in the field. However, distinguishing among various HBs that exhibit similar C, N, O, H, or trace metal atomic emissions complicates HB detection by LIBS. This paper proposes the use of LIBS and chemometric tools to discriminate Staphylococcus aureus, Bacillus cereus, and Escherichia coli on slide substrates. Principal component analysis (PCA) and the genetic algorithm (GA) were used to select features and reduce the size of spectral data. Several models based on the artificial neural network (ANN) and the support vector machine (SVM) were built using the feature lines as input data. The proposed PCA-GA-ANN and PCA-GA-SVM discrimination approaches exhibited correct classification rates of 97.5% and 100%, respectively.
Collapse
|
23
|
Preparation and characterization of carboxymethyl cashew gum grafted with immobilized antibody for potential biosensor application. Carbohydr Polym 2020; 228:115408. [PMID: 31635742 DOI: 10.1016/j.carbpol.2019.115408] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 09/27/2019] [Accepted: 09/29/2019] [Indexed: 11/27/2022]
Abstract
This report details the design of carboxymethylated cashew gum (CG) as a platform for antibody (Ab) immobilization, which can then be used as a biosensor for bacteria detection. The CG was isolated and characterized, followed by conversion to carboxymethyl cashew gum (CMCG). The CMCG film was a viable support for antibody immobilization; it was electrodeposited on gold surface using the cyclic voltammetry technique, applying a potential sweep from -1.0 V to 1.3 V with a scan rate of 50 mV s-1 and 10 scans. The COOH groups on the surface of the film were critical in promoting Ab bonding. The immobilization of the Ab was mediated by protein A (PrA) for recognition of the antigen. Voltammetry studies were used to monitor the antibody immobilization. Finally, the analytical response of the CMCG-PrA-Ab system was evaluated with the chronoamperometry technique and was found to detect Salmonella Typhimurium bacteria rapidly and efficiently.
Collapse
|
24
|
|
25
|
Nanoparticle Enhanced Antibody and DNA Biosensors for Sensitive Detection of Salmonella. MATERIALS 2018; 11:ma11091541. [PMID: 30150524 PMCID: PMC6163637 DOI: 10.3390/ma11091541] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Revised: 08/21/2018] [Accepted: 08/22/2018] [Indexed: 12/16/2022]
Abstract
Bacteria-related pathogenic diseases are one of the major health problems throughout the world. Salmonella is a genus of rod-shaped Gram-negative enterobacteria of which more than 2600 serotypes have been identified. Infection with Salmonella can cause salmonellosis, a serious bacterial toxi-infection syndrome associated with gastroenteritis, and paralyphoid and typhoid fevers. Its rapid and sensitive detection is a key to the prevention of problems related to health. This paper describes the development of antibody and DNA sensors for Salmonella detection using a microfluidic-based electrochemical system. Commercial Salmonella typhimurium and Salmonella typhimurium from human stool samples were investigated using standard and nanomaterial-amplified antibody sensors. S. typhimurium could be detected down to 1 cfu mL-1. The specificity of immunoassay was tested by studying with non-specific bacteria including E. coli and S. aureus that revealed only 2.01% and 2.66% binding when compared to the target bacterium. On the other hand, the quantification of Salmonella DNA was investigated in a concentration range of 0.002⁻200 µM using the developed DNA biosensor that demonstrated very high specificity and sensitivity with a detection limit of 0.94 nM. Our custom-designed microfluidic sensor offers rapid, highly sensitive, and specific diagnostic assay approaches for pathogen detection.
Collapse
|
26
|
Construction of Chitosan-Zn-Based Electrochemical Biosensing Platform for Rapid and Accurate Assay of Actin. SENSORS 2018; 18:s18061865. [PMID: 29875352 PMCID: PMC6021900 DOI: 10.3390/s18061865] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Revised: 05/28/2018] [Accepted: 06/05/2018] [Indexed: 01/21/2023]
Abstract
This work reports a study on the development of a sensitive immunosensor for the assay of actin, which is fabricated using sensing material chitosan-Zn nanoparticles (NPs) and anti-actin modified on glassy carbon electrode respectively. The prepared materials were characterized using transmission electron microscope (TEM), fourier transform infrared spectra (FTIR), X-ray diffraction (XRD) spectra, and circular dichroism (CD) techniques. Meanwhile, the electrochemical properties were studied by linear sweep voltammetric (LSV), electrochemical impedance spectra (EIS), and differential pulse voltammetry (DPV). According to the experiments, under the optimum conditions, the linear fitting equation was I (μA) = −17.31 + 78.97c (R2 = 0.9948). The linear range was from 0.0001 to 0.1 mg/mL and the detection limit (LOD, S/N = 3) was 21.52 ng/mL. The interference studies were also performed for checking the sensors’ selectivity to actin. With better properties of the chitosan-Zn NPs, the modified electrode is considered as a better candidate than Western blot or immunohistochemical method for real-time usability. The detection limit reported is the lowest till date and this method provides a new approach for quality evaluation.
Collapse
|
27
|
Recent advances in rapid pathogen detection method based on biosensors. Eur J Clin Microbiol Infect Dis 2018; 37:1021-1037. [DOI: 10.1007/s10096-018-3230-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Accepted: 03/12/2018] [Indexed: 12/28/2022]
|
28
|
|
29
|
Recent trends in the development of complementary metal oxide semiconductor image sensors to detect foodborne bacterial pathogens. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2017.10.019] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
30
|
Fluorometric graphene oxide-based detection of Salmonella enteritis using a truncated DNA aptamer. Mikrochim Acta 2017; 185:61. [PMID: 29594712 DOI: 10.1007/s00604-017-2601-9] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 12/01/2017] [Indexed: 02/07/2023]
Abstract
The work describes a fluorescence-based study for mapping the highest affinity truncated aptamer from the full length sequence and its integration in a graphene oxide platform for the detection of Salmonella enteriditis. To identify the best truncated sequence, molecular beacons and a displacement assay design are applied. In the fluorescence displacement assay, the truncated aptamer was hybridized with fluorescein and quencher-labeled complementary sequences to form a fluorescence/quencher pair. In the presence of S. enteritidis, the aptamer dissociates from the complementary labeled oligonucleotides and thus, the fluorescein/quencher pair becomes physically separated. This leads to an increase in fluorescence intensity. One of the truncated aptamers identified has a 2-fold lower dissociation constant (3.2 nM) compared to its full length aptamer (6.3 nM). The truncated aptamer selected in this process was used to develop a fluorometric graphene oxide (GO) based assay. If fluorescein-labeled aptamer is adsorbed on GO via π stacking interaction, fluorescence is quenched. However, in the presence of target (S. enteriditis), the labeled aptamers is released from surface to form a stable complex with the bacteria and fluorescence is restored, depending on the quantity of bacteria being present. The resulting assay has an unsurpassed detection limit of 25 cfu·mL-1 in the best case. The cross reactivity to Salmonella typhimurium, Staphylococcus aureus and Escherichia coli is negligible. The assay was applied to analyze doped milk samples for and gave good recovery. Thus, we believe that the truncated aptamer/graphene oxide platform is a potential tool for the detection of S. Enteritidis. Graphical abstract Fluorescently labelled aptamer against Salmonella enteritidis was adsorbed on the surface of graphene oxide by π-stacking interaction. This results in quenching of the fluorescence of the label. Addition of Salmonella enteritidis restores fluorescence, and this effect is used for quantification of this food-borne pathogen.
Collapse
|
31
|
Rapid detection of food-borne Salmonella contamination using IMBs-qPCR method based on pagC gene. Braz J Microbiol 2017; 49:320-328. [PMID: 29108975 PMCID: PMC5914203 DOI: 10.1016/j.bjm.2017.09.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 07/20/2017] [Accepted: 09/11/2017] [Indexed: 11/23/2022] Open
Abstract
Detection of Salmonella is very important to minimize the food safety risk. In this study, the recombinant PagC protein and PagC antibody were prepared and coupled with immunomagnetic beads (IMBs) to capture Salmonella cells from pork and milk samples. And then the SYBR Green qualitative PCR was developed to detect the pathogenic Salmonella. The results showed that the PagC polyclonal antiserum is of good specificity and the capture rate of 0.1 mg IMBs for Salmonella tended to be stable at the range of 70–74% corresponding to the concentrations between 101 and 104 CFU/mL. The method developed demonstrated high specificity for the positive Salmonella samples when compared to non-specific DNA samples, such as Escherichia coli, Staphylococcus aureus, Yersinia enterocolitica, and Yersinia pseudotuberculosis. The limit of detection of this assay was 18 CFU/mL. Detection and quantitative enumeration of Salmonella in samples of pork or milk shows good recoveries of 54.34% and 52.07%. In conclusion, the polyclonal antibody of recombinant PagC protein is effective to capture Salmonella from detected samples. The developed pagC antibody IMBs-qPCR method showed efficiency, sensitivity and specificity for 30 Salmonella detection, enabling detection within 10 h, which is a promising rapid method to detect Salmonella in emergency.
Collapse
|
32
|
Electrochemical Biosensors for Rapid Detection of Foodborne Salmonella: A Critical Overview. SENSORS 2017; 17:s17081910. [PMID: 28820458 PMCID: PMC5579882 DOI: 10.3390/s17081910] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Revised: 08/13/2017] [Accepted: 08/13/2017] [Indexed: 12/11/2022]
Abstract
Salmonella has represented the most common and primary cause of food poisoning in many countries for at least over 100 years. Its detection is still primarily based on traditional microbiological culture methods which are labor-intensive, extremely time consuming, and not suitable for testing a large number of samples. Accordingly, great efforts to develop rapid, sensitive and specific methods, easy to use, and suitable for multi-sample analysis, have been made and continue. Biosensor-based technology has all the potentialities to meet these requirements. In this paper, we review the features of the electrochemical immunosensors, genosensors, aptasensors and phagosensors developed in the last five years for Salmonella detection, focusing on the critical aspects of their application in food analysis.
Collapse
|
33
|
Electrochemical biosensors for Salmonella: State of the art and challenges in food safety assessment. Biosens Bioelectron 2017; 99:667-682. [PMID: 28858763 DOI: 10.1016/j.bios.2017.08.019] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 08/03/2017] [Accepted: 08/07/2017] [Indexed: 10/19/2022]
Abstract
According to the recent statistics, Salmonella is still an important public health issue in the whole world. Legislated reference methods, based on counting plate methods, are sensitive enough but are inadequate as an effective emergency response tool, and are far from a rapid device, simple to use out of lab. An overview of the commercially available rapid methods for Salmonella detection is provided along with a critical discussion of their limitations, benefits and potential use in a real context. The distinguished potentialities of electrochemical biosensors for the development of rapid devices are highlighted. The state-of-art and the newest technologic approaches in electrochemical biosensors for Salmonella detection are presented and a critical analysis of the literature is made in an attempt to identify the current challenges towards a complete solution for Salmonella detection in microbial food control based on electrochemical biosensors.
Collapse
|
34
|
|