Uraoka D, Matsuda M, Tanabe Y, Kawaguchi N, Nishiyama C, Okada A, Uda K, Suekuni H, Nishiyama H, Kamei Y, Kurata M, Kitazawa R, Nakano S, Kido T. Usefulness of four-dimensional noise reduction filtering using a similarity algorithm in low-dose dynamic computed tomography for the evaluation of breast cancer: a preliminary study. Jpn J Radiol 2025; 43:787-799. [PMID: 39849240 PMCID: PMC12053336 DOI: 10.1007/s11604-024-01730-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2024] [Accepted: 12/28/2024] [Indexed: 01/25/2025]
Abstract
PURPOSE To evaluate the effects of four-dimensional noise reduction filtering using a similarity algorithm (4D-SF) on the image quality and tumor visibility of low-dose dynamic computed tomography (CT) in evaluating breast cancer. MATERIALS AND METHODS Thirty-four patients with 38 lesions who underwent low-dose dynamic breast CT and were pathologically diagnosed with breast cancer were enrolled. Dynamic CT images were reconstructed using iterative reconstruction alone or in combination with 4D-SF. We selected the peak enhancement phase image of breast cancer for each patient for quantitative and qualitative evaluations of image quality and measurement of the maximum diameter of breast cancer. The signal-to-noise and contrast-to-noise ratios were calculated for quantitative evaluation. The maximum diameters of the breast cancer were measured from the images obtained with and without 4D-SF (4D-SF ±) (size-4D-SF + and size-4D-SF-) and for the pathological specimen (size-PS) and compared. RESULTS The median and interquartile ranges of the signal-to-noise ratio [4D-SF-: 3.03 (2.54-4.17) vs 4D-SF + : 5.52 (4.75-6.66)] and contrast-to-noise ratio [4D-SF-: 2.88 (2.00-3.60) vs 4D-SF + : 7.84 (4.65-10.35)] were significantly higher for 4D-SF + than for 4D-SF- (p < 0.001). The overall image quality (Observer 1, p < 0.001; Observer 2, p < 0.001) and tumor margin sharpness scores (Observer 1, p = 0.003; Observer 2, p < 0.001) were significantly higher for 4D-SF + than for 4D-SF-. The tumor contrast scores for 4D-SF + and 4D-SF- were not significantly different (Observers 1, 2; p = 0.083). Size-4D-SF- was significantly smaller than size-PS (p < 0.001); size-4D-SF + was also smaller than size-PS, but the difference was not significant (p = 0.088). The Spearman's rank correlation coefficient was 0.65 for size-PS and size-4D-SF- and 0.77 for size-PS and size-4D-SF + . CONCLUSION The 4D-SF can improve the image quality and tumor visibility of low-dose dynamic CT in evaluating breast cancer extent due to noise reduction.
Collapse
Affiliation(s)
- Daichi Uraoka
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Megumi Matsuda
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
| | - Yuki Tanabe
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Naoto Kawaguchi
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Chihiro Nishiyama
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Ayaka Okada
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Koichiro Uda
- Department of Radiology, Ehime Prefectural Central Hospital, Kasugamachi, Matsuyama, Ehime, 790-0024, Japan
| | - Hiroshi Suekuni
- Department of Radiology, Ehime University Hospital, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Hikaru Nishiyama
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Yoshiaki Kamei
- Breast Center, Ehime University Hospital, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Mie Kurata
- Department of Pathology, Ehime University Proteo-Science Center, Shitsukawa, Toon, Ehime, 791-0295, Japan
- Department of Analytical Pathology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Riko Kitazawa
- Division of Diagnostic Pathology, Ehime University Hospital, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Shota Nakano
- Canon Medical Systems Corporation, Shimoishigami, Otawara, Tochigi, 324-8550, Japan
| | - Teruhito Kido
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| |
Collapse
|
2
|
Li M, Guo X, Verma A, Rudkouskaya A, McKenna AM, Intes X, Wang G, Barroso M. Contrast-enhanced photon-counting micro-CT of tumor xenograft models. Phys Med Biol 2024; 69:155011. [PMID: 38670143 PMCID: PMC11258216 DOI: 10.1088/1361-6560/ad4447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 04/11/2024] [Accepted: 04/26/2024] [Indexed: 04/28/2024]
Abstract
Objective. Photon-counting micro-computed tomography (micro-CT) is a major advance in small animal preclinical imaging. Small molecule- and nanoparticle-based contrast agents have been widely used to enable the differentiation of liver tumors from surrounding tissues using photon-counting micro-CT. However, there is a notable gap in the application of these market-available agents to the imaging of breast and ovarian tumors using photon-counting micro-CT. Herein, we have used photon-counting micro-CT to determine the effectiveness of these contrast agents in differentiating ovarian and breast tumor xenografts in live, intact mice.Approach. Nude mice carrying different types of breast and ovarian tumor xenografts (AU565, MDA-MB-231 and SKOV-3 human cancer cells) were injected with ISOVUE-370 (a small molecule-based agent) or Exitron Nano 12000 (a nanoparticle-based agent) and subjected to photon-counting micro-CT. To improve tumor visualization using photon-counting micro-CT, we developed a novel color visualization method, which changes color tones to highlight contrast media distribution, offering a robust alternative to traditional material decomposition methods with less computational demand.Main results. Ourin vivoexperiments confirm the effectiveness of this color visualization approach, showing distinct enhancement characteristics for each contrast agent. Qualitative and quantitative analyses suggest that Exitron Nano 12000 provides superior vasculature enhancement and better quantitative consistency across scans, while ISOVUE-370 delivers a more comprehensive tumor enhancement but with significant variance between scans due to its short blood half-time. Further, a paired t-test on mean and standard deviation values within tumor volumes showed significant differences between the AU565 and SKOV-3 tumor models with the nanoparticle-based contrast agent (p-values < 0.02), attributable to their distinct vascularity, as confirmed by immunohistochemical analysis.Significance. These findings underscore the utility of photon-counting micro-CT in non-invasively assessing the morphology and anatomy of different tumor xenografts, which is crucial for tumor characterization and longitudinal monitoring of tumor progression and response to treatments.
Collapse
Affiliation(s)
- Mengzhou Li
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America
| | - Xiaodong Guo
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America
| | - Amit Verma
- Department of Molecular and Cellular Physiology, Albany Medical College, Albany, NY 12208, United States of America
| | - Alena Rudkouskaya
- Department of Molecular and Cellular Physiology, Albany Medical College, Albany, NY 12208, United States of America
| | - Antigone M McKenna
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America
| | - Xavier Intes
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America
| | - Ge Wang
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, United States of America
| | - Margarida Barroso
- Department of Molecular and Cellular Physiology, Albany Medical College, Albany, NY 12208, United States of America
| |
Collapse
|
3
|
Lee DH, Lee JM, Lee CH, Afat S, Othman A. Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT. Radiol Artif Intell 2024; 6:e230192. [PMID: 38231025 PMCID: PMC10982822 DOI: 10.1148/ryai.230192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 11/13/2023] [Accepted: 01/02/2024] [Indexed: 01/18/2024]
Abstract
Purpose To compare the image quality and diagnostic capability in detecting malignant liver tumors of low-dose CT (LDCT, 33% dose) with deep learning-based denoising (DLD) and standard-dose CT (SDCT, 100% dose) with model-based iterative reconstruction (MBIR). Materials and Methods In this prospective, multicenter, noninferiority study, individuals referred for liver CT scans were enrolled from three tertiary referral hospitals between February 2021 and August 2022. All liver CT scans were conducted using a dual-source scanner with the dose split into tubes A (67% dose) and B (33% dose). Blended images from tubes A and B were created using MBIR to produce SDCT images, whereas LDCT images used data from tube B and were reconstructed with DLD. The noise in liver images was measured and compared between imaging techniques. The diagnostic performance of each technique in detecting malignant liver tumors was evaluated by three independent radiologists using jackknife alternative free-response receiver operating characteristic analysis. Noninferiority of LDCT compared with SDCT was declared when the lower limit of the 95% CI for the difference in figure of merit (FOM) was greater than -0.10. Results A total of 296 participants (196 men, 100 women; mean age, 60.5 years ± 13.3 [SD]) were included. The mean noise level in the liver was significantly lower for LDCT (10.1) compared with SDCT (10.7) (P < .001). Diagnostic performance was assessed in 246 participants (108 malignant tumors in 90 participants). The reader-averaged FOM was 0.880 for SDCT and 0.875 for LDCT (P = .35). The difference fell within the noninferiority margin (difference, -0.005 [95% CI: -0.024, 0.012]). Conclusion Compared with SDCT with MBIR, LDCT using 33% of the standard radiation dose had reduced image noise and comparable diagnostic performance in detecting malignant liver tumors. Keywords: CT, Abdomen/GI, Liver, Comparative Studies, Diagnosis, Reconstruction Algorithms Clinical trial registration no. NCT05804799 © RSNA, 2024 Supplemental material is available for this article.
Collapse
Affiliation(s)
- Dong Ho Lee
- From the Departments of Radiology of Seoul National University
Hospital, Seoul, South Korea (D.H.L., J.M.L.); Seoul National University
Hospital, Seoul National University College of Medicine, 101 Daehak-ro,
Jongno-gu, Seoul 03080, South Korea (D.H.L., J.M.L.); Korea University Guro
Hospital, Korea University Medicine, Seoul, South Korea (C.H.L.); and
Tübingen University Hospital, Tübingen, Germany (S.A.,
A.O.)
| | - Jeong Min Lee
- From the Departments of Radiology of Seoul National University
Hospital, Seoul, South Korea (D.H.L., J.M.L.); Seoul National University
Hospital, Seoul National University College of Medicine, 101 Daehak-ro,
Jongno-gu, Seoul 03080, South Korea (D.H.L., J.M.L.); Korea University Guro
Hospital, Korea University Medicine, Seoul, South Korea (C.H.L.); and
Tübingen University Hospital, Tübingen, Germany (S.A.,
A.O.)
| | - Chang Hee Lee
- From the Departments of Radiology of Seoul National University
Hospital, Seoul, South Korea (D.H.L., J.M.L.); Seoul National University
Hospital, Seoul National University College of Medicine, 101 Daehak-ro,
Jongno-gu, Seoul 03080, South Korea (D.H.L., J.M.L.); Korea University Guro
Hospital, Korea University Medicine, Seoul, South Korea (C.H.L.); and
Tübingen University Hospital, Tübingen, Germany (S.A.,
A.O.)
| | - Saif Afat
- From the Departments of Radiology of Seoul National University
Hospital, Seoul, South Korea (D.H.L., J.M.L.); Seoul National University
Hospital, Seoul National University College of Medicine, 101 Daehak-ro,
Jongno-gu, Seoul 03080, South Korea (D.H.L., J.M.L.); Korea University Guro
Hospital, Korea University Medicine, Seoul, South Korea (C.H.L.); and
Tübingen University Hospital, Tübingen, Germany (S.A.,
A.O.)
| | - Ahmed Othman
- From the Departments of Radiology of Seoul National University
Hospital, Seoul, South Korea (D.H.L., J.M.L.); Seoul National University
Hospital, Seoul National University College of Medicine, 101 Daehak-ro,
Jongno-gu, Seoul 03080, South Korea (D.H.L., J.M.L.); Korea University Guro
Hospital, Korea University Medicine, Seoul, South Korea (C.H.L.); and
Tübingen University Hospital, Tübingen, Germany (S.A.,
A.O.)
| |
Collapse
|
4
|
Li M, Guo X, Verma A, Rudkouskaya A, McKenna AM, Intes X, Wang G, Barroso M. Contrast-enhanced photon-counting micro-CT of tumor xenograft models. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.01.03.574097. [PMID: 38260707 PMCID: PMC10802390 DOI: 10.1101/2024.01.03.574097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2024]
Abstract
Photon-counting micro computed tomography (micro-CT) offers new potential in preclinical imaging, particularly in distinguishing materials. It becomes especially helpful when combined with contrast agents, enabling the differentiation of tumors from surrounding tissues. There are mainly two types of contrast agents in the market for micro-CT: small molecule-based and nanoparticle-based. However, despite their widespread use in liver tumor studies, there is a notable gap in research on the application of these commercially available agents for photon-counting micro-CT in breast and ovarian tumors. Herein, we explored the effectiveness of these agents in differentiating tumor xenografts from various origins (AU565, MDA-MB-231, and SKOV-3) in nude mice, using photon-counting micro-CT. Specifically, ISOVUE-370 (a small molecule-based agent) and Exitrone Nano 12000 (a nanoparticle-based agent) were investigated in this context. To improve tumor visualization, we proposed a novel color visualization method for photon-counting micro-CT, which changes color tones to highlight contrast media distribution, offering a robust alternative to traditional material decomposition methods with less computational demand. Our in vivo experiments confirm its effectiveness, showing distinct enhancement characteristics for each contrast agent. Qualitative and quantitative analyses suggested that Exitrone Nano 12000 provides superior vasculature enhancement and better quantitative consistency across scans, while ISOVUE-370 gives more comprehensive tumor enhancement but with a significant variance between scans due to its short blood half-time. This variability leads to high sensitivity to timing and individual differences among mice. Further, a paired t-test on mean and standard deviation values within tumor volumes showed significant differences between the AU565 and SKOV-3 tumor models with the nanoparticle-based (p-values < 0.02), attributable to their distinct vascularity, as confirmed by immunohistochemistry. These findings underscore the utility of photon-counting micro-CT in non-invasively assessing the morphology and anatomy of different tumor xenografts, which is crucial for tumor characterization and longitudinal monitoring of tumor development and response to treatments.
Collapse
Affiliation(s)
- Mengzhou Li
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Xiaodong Guo
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Amit Verma
- Department of Molecular and Cellular Physiology, Albany Medical College, Albany, NY 12208, USA
| | - Alena Rudkouskaya
- Department of Molecular and Cellular Physiology, Albany Medical College, Albany, NY 12208, USA
| | - Antigone M. McKenna
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Xavier Intes
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Ge Wang
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Margarida Barroso
- Department of Molecular and Cellular Physiology, Albany Medical College, Albany, NY 12208, USA
| |
Collapse
|
5
|
Yamamoto Y, Tanabe Y, Kurata A, Yamamoto S, Kido T, Uetani T, Ikeda S, Nakano S, Yamaguchi O, Kido T. Feasibility of four-dimensional similarity filter for radiation dose reduction in dynamic myocardial computed tomography perfusion imaging. FRONTIERS IN RADIOLOGY 2023; 3:1214521. [PMID: 38105799 PMCID: PMC10722229 DOI: 10.3389/fradi.2023.1214521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Accepted: 11/20/2023] [Indexed: 12/19/2023]
Abstract
Rationale and objectives We aimed to evaluate the impact of four-dimensional noise reduction filtering using a four-dimensional similarity filter (4D-SF) on radiation dose reduction in dynamic myocardial computed tomography perfusion (CTP). Materials and methods Forty-three patients who underwent dynamic myocardial CTP using 320-row computed tomography (CT) were included in the study. The original images were reconstructed using iterative reconstruction (IR). Three different CTP datasets with simulated noise, corresponding to 25%, 50%, and 75% reduction of the original dose (300 mA), were reconstructed using a combination of IR and 4D-SF. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed, and CT-derived myocardial blood flow (CT-MBF) was quantified. The results were compared between the original and simulated images with radiation dose reduction. Results The median SNR (first quartile-third quartile) at the original, 25%-, 50%-, and 75%-dose reduced-simulated images with 4D-SF was 8.3 (6.5-10.2), 16.5 (11.9-21.7), 15.6 (11.0-20.1), and 12.8 (8.8-18.1) and that of CNR was 4.4 (3.2-5.8), 6.7 (4.6-10.3), 6.6 (4.3-10.1), and 5.5 (3.5-9.1), respectively. All the dose-reduced-simulated CTPs with 4D-SF had significantly higher image quality scores in SNR and CNR than the original ones (25%-, 50%-, and 75%-dose reduced vs. original images, p < 0.05, in each). The CT-MBF in 75%-dose reduced-simulated CTP was significantly lower than 25%-, 50%- dose-reduced-simulated, and original CTPs (vs. 75%-dose reduced-simulated images, p < 0.05, in each). Conclusion 4D-SF has the potential to reduce the radiation dose associated with dynamic myocardial CTP imaging by half, without impairing the robustness of MBF quantification.
Collapse
Affiliation(s)
- Yuta Yamamoto
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Yuki Tanabe
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Akira Kurata
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
- Department of Cardiology, National Hospital Organization Shikoku Cancer Center, Matsuyama, Japan
| | - Shuhei Yamamoto
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Tomoyuki Kido
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Teruyoshi Uetani
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Shuntaro Ikeda
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Shota Nakano
- Canon Medical Systems Corporation, Otawara, Japan
| | - Osamu Yamaguchi
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Teruhito Kido
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| |
Collapse
|
6
|
Zdanowicz A, Guzinski M, Pula M, Witkowska A, Reczuch K. Dynamic CT Myocardial Perfusion: The Role of Functional Evaluation in the Diagnosis of Coronary Artery Disease. J Clin Med 2023; 12:7062. [PMID: 38002675 PMCID: PMC10672614 DOI: 10.3390/jcm12227062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 10/30/2023] [Accepted: 11/09/2023] [Indexed: 11/26/2023] Open
Abstract
Coronary computed tomography angiography (CTA) is a widely accepted, non-invasive diagnostic modality for the evaluation of patients with suspected coronary artery disease (CAD). However, a limitation of CTA is its inability to provide information on the hemodynamic significance of the coronary lesion. The recently developed stress dynamic CT perfusion technique has emerged as a potential solution to this diagnostic challenge. Dynamic CT myocardial perfusion provides information on the hemodynamic consequences of coronary stenosis and is used to detect myocardial ischemia. The combination of stress dynamic CT myocardial perfusion with CTA provides a comprehensive assessment that integrates anatomical and functional information. CT myocardial perfusion has been validated in several clinical studies and has shown comparable accuracy to Positron Emission Tomography (PET) and stress magnetic resonance imaging (MRI) in the diagnosis of hemodynamically significant coronary stenosis and superior performance to Single Photon Emission Computed Tomography (SPECT). More importantly, CTP-derived myocardial perfusion has been shown to have a strong correlation with FFR, and the use of CTP results in a reduction of negative catheterizations. In the context of suspected stable coronary artery disease, the CT protocol with dynamic perfusion imaging combined with CTA eliminates the need for additional testing, making it a convenient "one-stop-shop" method and an effective gatekeeper to an invasive approach.
Collapse
Affiliation(s)
- Agata Zdanowicz
- Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw, Poland;
| | - Maciej Guzinski
- Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw, Poland;
| | - Michal Pula
- Lower Silesian Oncology, Pulmonology and Hematology Center, Hirszfelda Square 12, 53-413 Wroclaw, Poland
| | - Agnieszka Witkowska
- Institute of Heart Diseases, University Clinical Hospital in Wroclaw, Borowska 213, 50-556 Wroclaw, Poland (K.R.)
| | - Krzysztof Reczuch
- Institute of Heart Diseases, University Clinical Hospital in Wroclaw, Borowska 213, 50-556 Wroclaw, Poland (K.R.)
- Department of Cardiology, Faculty of Medicine, Institute of Heart Diseases, Wroclaw Medical University, 50-367 Wroclaw, Poland
| |
Collapse
|
7
|
Møller MB, Schuijf JD, Oyama-Manabe N, Linde JJ, Kühl JT, Lima JAC, Kofoed KF. Technical Considerations for Dynamic Myocardial Computed Tomography Perfusion as Part of a Comprehensive Evaluation of Coronary Artery Disease Using Computed Tomography. J Thorac Imaging 2023; 38:54-68. [PMID: 36044617 DOI: 10.1097/rti.0000000000000673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Dynamic myocardial computed tomography perfusion (DM-CTP) has good diagnostic accuracy for identifying myocardial ischemia as compared with both invasive and noninvasive reference standards. However, DM-CTP has not yet been implemented in the routine clinical examination of patients with suspected or known coronary artery disease. An important hurdle in the clinical dissemination of the method is the development of the DM-CTP acquisition protocol and image analysis. Therefore, the aim of this article is to provide a review of critical parameters in the design and execution of DM-CTP to optimize each step of the examination and avoid common mistakes. We aim to support potential users in the successful implementation and performance of DM-CTP in daily practice. When performed appropriately, DM-CTP may support clinical decision making. In addition, when combined with coronary computed tomography angiography, it has the potential to shorten the time to diagnosis by providing immediate visualization of both coronary atherosclerosis and its functional relevance using one single modality.
Collapse
Affiliation(s)
- Mathias B Møller
- Department of Cardiology, Rigshospitalet, University of Copenhagen, The Heart Centre
| | - Joanne D Schuijf
- Global Research and Development Center, Canon Medical Systems Europe, Zoetermeer, The Netherlands
| | - Noriko Oyama-Manabe
- Department of Radiology, Jichi Medical University Saitama Medical Center, Saitama, Japan
| | - Jesper J Linde
- Department of Cardiology, Rigshospitalet, University of Copenhagen, The Heart Centre
| | - Jørgen T Kühl
- Department of Cardiology, Rigshospitalet, University of Copenhagen, The Heart Centre
| | - Joao A C Lima
- Departments of Medicine and Radiology, Johns Hopkins Hospital and School of Medicine, Baltimore, MD
| | - Klaus F Kofoed
- Department of Cardiology, Rigshospitalet, University of Copenhagen, The Heart Centre
- Department of Radiology, Rigshospitalet, University of Copenhagen
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
8
|
Takafuji M, Kitagawa K, Mizutani S, Oka R, Kisou R, Sakaguchi S, Ichikawa K, Izumi D, Sakuma H. Deep-learning reconstruction to improve image quality of myocardial dynamic CT perfusion: comparison with hybrid iterative reconstruction. Clin Radiol 2022; 77:e771-e775. [PMID: 35853777 DOI: 10.1016/j.crad.2022.06.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 06/22/2022] [Indexed: 12/01/2022]
Affiliation(s)
- M Takafuji
- Department of Radiology, Mie University Graduate School of Medicine, Tsu, Japan; Department of Radiology, Matsusaka Municipal Hospital, Matsusaka, Japan
| | - K Kitagawa
- Department of Radiology, Mie University Graduate School of Medicine, Tsu, Japan.
| | - S Mizutani
- Department of Radiology, Matsusaka Municipal Hospital, Matsusaka, Japan
| | - R Oka
- Department of Radiology, Matsusaka Municipal Hospital, Matsusaka, Japan
| | - R Kisou
- Department of Radiology, Matsusaka Municipal Hospital, Matsusaka, Japan
| | - S Sakaguchi
- Department of Cardiology, Matsusaka Municipal Hospital, Matsusaka, Japan
| | - K Ichikawa
- Department of Cardiology, Matsusaka Municipal Hospital, Matsusaka, Japan
| | - D Izumi
- Department of Cardiology, Matsusaka Municipal Hospital, Matsusaka, Japan
| | - H Sakuma
- Department of Radiology, Mie University Graduate School of Medicine, Tsu, Japan
| |
Collapse
|
9
|
Geng W, Gao Y, Zhao N, Yan H, Ma W, An Y, Jia L, Lu B. Dose Reduction of Dynamic Computed Tomography Myocardial Perfusion Imaging by Tube Voltage Change: Investigation in a Swine Model. Front Cardiovasc Med 2022; 9:823974. [PMID: 35310988 PMCID: PMC8927626 DOI: 10.3389/fcvm.2022.823974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Accepted: 02/15/2022] [Indexed: 11/18/2022] Open
Abstract
Background It is unclear whether tube voltage influences the measurement of perfusion parameters. The present study sought to evaluate the influence of tube voltage change on myocardial blood flow (MBF) measurements in dynamic computed tomography myocardial perfusion imaging (CTP). Methods and Results Seven swine [mean weight 55.8 kg ± 1.6 (standard deviation)] underwent rest and stress dynamic CTP with tube voltages of 100 and 70 kV. The image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), radiation dose and MBF value were compared. The 70 kV images had higher CT attenuation and higher image noise (27.9 ± 2.4 vs. 21.5 ± 1.9, P < 0.001) than the 100 kV images, resulting in a higher SNR (20.5 ± 1.6 vs. 15.6 ± 1.8, P < 0.001) and CNR (17.6 ± 1.5 vs. 12.4 ± 1.7, P < 0.001). Compared to the use of conventional 100 kV, 70 kV yielded an approximately 64.6% radiation dose reduction while generating comparable MBF values, both at rest (88.3 ± 14.9 ml/100 g/min vs. 85.6 ± 17.4 ml/100 g/min, P = 0.21) and stress (101.4 ± 21.5 ml/100 g/min vs. 99.6 ± 21.4 ml/100 g/min, P = 0.58) states. Conclusion Dynamic CTP using 70 kV instead of 100 kV does not substantially influence the MBF value but significantly reduces the radiation dose. Additional research is required to investigate the clinical significance of this change.
Collapse
Affiliation(s)
- Wenlei Geng
- Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Yang Gao
- Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Na Zhao
- Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Hankun Yan
- Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Wei Ma
- Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Yunqiang An
- Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Liujun Jia
- Animal Experimental Center, Beijing Key Laboratory of Pre-Clinical Research and Evaluation for Cardiovascular Implant Materials, State Key Laboratory of Cardiovascular Disease, Beijing, China
| | - Bin Lu
- Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
- *Correspondence: Bin Lu,
| |
Collapse
|
10
|
Image quality in liver CT: low-dose deep learning vs standard-dose model-based iterative reconstructions. Eur Radiol 2021; 32:2865-2874. [PMID: 34821967 DOI: 10.1007/s00330-021-08380-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 09/15/2021] [Accepted: 10/04/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVES To compare the overall image quality and detectability of significant (malignant and pre-malignant) liver lesions of low-dose liver CT (LDCT, 33.3% dose) using deep learning denoising (DLD) to standard-dose CT (SDCT, 100% dose) using model-based iterative reconstruction (MBIR). METHODS In this retrospective study, CT images of 80 patients with hepatic focal lesions were included. For noninferiority analysis of overall image quality, a margin of - 0.5 points (scored in a 5-point scale) for the difference between scan protocols was pre-defined. Other quantitative or qualitative image quality assessments were performed. Additionally, detectability of significant liver lesions was compared, with 64 pairs of CT, using the jackknife alternative free-response ROC analysis, with noninferior margin defined by the lower limit of 95% confidence interval (CI) of the difference of figure-of-merit less than - 0.1. RESULTS The mean overall image quality scores with LDCT and SDCT were 3.77 ± 0.38 and 3.94 ± 0.34, respectively, demonstrating a difference of - 0.17 (95% CI: - 0.21 to - 0.12), which did not cross the predefined noninferiority margin of - 0.5. Furthermore, LDCT showed significantly superior quantitative results of liver lesion contrast to noise ratio (p < 0.05). However, although LDCT scored higher than the average score in qualitative image quality assessments, they were significantly lower than those of SDCT (p < 0.05). Figure-of-merit for lesion detection was 0.859 for LDCT and 0.878 for SDCT, showing noninferiority (difference: - 0.019, 95% CI: - 0.058 to 0.021). CONCLUSION LDCT using DLD with 67% radiation dose reduction showed non-inferior overall image quality and lesion detectability, compared to SDCT. KEY POINTS • Low-dose liver CT using deep learning denoising (DLD), at 67% dose reduction, provided non-inferior overall image quality compared to standard-dose CT using model-based iterative reconstruction (MBIR). • Low-dose CT using DLD showed significantly less noise and higher CNR lesion to liver than standard-dose CT using MBIR and demonstrated at least average image quality score among all readers, albeit with lower scores than standard-dose CT using MBIR. • Low-dose liver CT showed noninferior detectability for malignant and pre-malignant liver lesions, compared to standard-dose CT.
Collapse
|
11
|
Liu J, Jin S, Li Q, Zhang K, Yu J, Mo Y, Bian Z, Gao Y, Zhang H. Motion compensation combining with local low rank regularization for low dose dynamic CT myocardial perfusion reconstruction. Phys Med Biol 2021; 66. [PMID: 34181588 DOI: 10.1088/1361-6560/ac0f2f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 06/28/2021] [Indexed: 11/11/2022]
Abstract
Dynamic CT myocardial perfusion imaging (DCT-MPI) is a reliable examination tool for the assessment of myocardium and vascular, while its special scan protocol may result in excessive radiation exposure to patients and inevitable inter-frame motion. Lowering the tube current is a simple way to reduce radiation exposure. However, low mAs will certainly cause severe image noise, thus may further impact the accuracy of functional hemodynamic parameters, which are used for the assessment of blood supply. In this work, we present a novel scheme applying motion compensation and local low rank regularization (MC-LLR) for obtaining high quality motion compensated DCT-MPI images. Specifically, motion compensation by using robust data decomposition registration (RDDR) was introduced. Robust principal component analysis coupled with optical flow-based registration algorithm were used in RDDR. Then, the local low rank constraint on the motion compensated time series images was applied for the DCT-MPI reconstruction. One healthy mini pig and two patient datasets were used to evaluate the proposed MC-LLR algorithm. Results show that the present method achieved satisfactory image quality with higher CNRs, smaller rRMSEs, and more accurate hemodynamic parameter maps.
Collapse
Affiliation(s)
- Jia Liu
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| | - Shuang Jin
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| | - Qian Li
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| | - Kunpeng Zhang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| | - Jiahong Yu
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| | - Ying Mo
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| | - Zhaoying Bian
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| | - Yang Gao
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| | - Hua Zhang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, People's Republic of China.,Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, People's Republic of China
| |
Collapse
|
12
|
Brady SL, Trout AT, Somasundaram E, Anton CG, Li Y, Dillman JR. Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction. Radiology 2020; 298:180-188. [PMID: 33201790 DOI: 10.1148/radiol.2020202317] [Citation(s) in RCA: 96] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background CT deep learning reconstruction (DLR) algorithms have been developed to remove image noise. How the DLR affects image quality and radiation dose reduction has yet to be fully investigated. Purpose To investigate a DLR algorithm's dose reduction and image quality improvement for pediatric CT. Materials and Methods DLR was compared with filtered back projection (FBP), statistical-based iterative reconstruction (SBIR), and model-based iterative reconstruction (MBIR) in a retrospective study by using data from CT examinations of pediatric patients (February to December 2018). A comparison of object detectability for 15 objects (diameter, 0.5-10 mm) at four contrast difference levels (50, 150, 250, and 350 HU) was performed by using a non-prewhitening-matched mathematical observer model with eye filter (d'NPWE), task transfer function, and noise power spectrum analysis. Object detectability was assessed by using area under the curve analysis. Three pediatric radiologists performed an observer study to assess anatomic structures with low object-to-background signal and contrast to noise in the azygos vein, right hepatic vein, common bile duct, and superior mesenteric artery. Observers rated from 1 to 10 (worst to best) for edge definition, quantum noise level, and object conspicuity. Analysis of variance and Tukey honest significant difference post hoc tests were used to analyze differences between reconstruction algorithms. Results Images from 19 patients (mean age, 11 years ± 5 [standard deviation]; 10 female patients) were evaluated. Compared with FBP, SBIR, and MBIR, DLR demonstrated improved object detectability by 51% (16.5 of 10.9), 18% (16.5 of 13.9), and 11% (16.5 of 14.8), respectively. DLR reduced image noise without noise texture effects seen with MBIR. Radiologist ratings were 7 ± 1 (DLR), 6.2 ± 1 (MBIR), 6.2 ± 1 (SBIR), and 4.6 ± 1 (FBP); two-way analysis of variance showed a difference on the basis of reconstruction type (P < .001). Radiologists consistently preferred DLR images (intraclass correlation coefficient, 0.89; 95% CI: 0.83, 0.93). DLR demonstrated 52% (1 of 2.1) greater dose reduction than SBIR. Conclusion The DLR algorithm improved image quality and dose reduction without sacrificing noise texture and spatial resolution. © RSNA, 2020 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Samuel L Brady
- From the Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333, Burnet Ave, Cincinnati, OH 45329; and Department of Radiology, University of Cincinnati Medical School, Cincinnati, Ohio
| | - Andrew T Trout
- From the Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333, Burnet Ave, Cincinnati, OH 45329; and Department of Radiology, University of Cincinnati Medical School, Cincinnati, Ohio
| | - Elanchezhian Somasundaram
- From the Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333, Burnet Ave, Cincinnati, OH 45329; and Department of Radiology, University of Cincinnati Medical School, Cincinnati, Ohio
| | - Christopher G Anton
- From the Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333, Burnet Ave, Cincinnati, OH 45329; and Department of Radiology, University of Cincinnati Medical School, Cincinnati, Ohio
| | - Yinan Li
- From the Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333, Burnet Ave, Cincinnati, OH 45329; and Department of Radiology, University of Cincinnati Medical School, Cincinnati, Ohio
| | - Jonathan R Dillman
- From the Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333, Burnet Ave, Cincinnati, OH 45329; and Department of Radiology, University of Cincinnati Medical School, Cincinnati, Ohio
| |
Collapse
|
13
|
Woisetschläger M, Henriksson L, Bartholomae W, Gasslander T, Björnsson B, Sandström P. Iterative reconstruction algorithm improves the image quality without affecting quantitative measurements of computed tomography perfusion in the upper abdomen. Eur J Radiol Open 2020; 7:100243. [PMID: 32642503 PMCID: PMC7334814 DOI: 10.1016/j.ejro.2020.100243] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 06/17/2020] [Accepted: 06/19/2020] [Indexed: 12/26/2022] Open
Abstract
Iterative image-reconstruction algorithm (ADMIRE) did not affect the quantitative measurements in CT perfusion. Iterative image-reconstruction algorithm (ADMIRE) did not affect the time attenuation curves in CT perfusion. Image noise was lower, but the SNR was higher, for iterative reconstructions in CT perfusion examinations with higher strength of noise reduction.
Objective To investigate differences between reconstruction algorithms in quantitative perfusion values and time-attenuation curves in computed tomography perfusion (CTP) examinations of the upper abdomen. Methods Twenty-six CTP examinations were reconstructed with filtered back projection and an iterative reconstruction algorithm, advanced modeled iterative reconstruction (ADMIRE), with different levels of noise-reduction strength. Using the maximum-slope model, quantitative measurements were obtained: blood flow (mL/min/100 mL), blood volume (mL/100 mL), time to peak (s), arterial liver perfusion (mL/100 mL/min), portal venous liver perfusion (mL/100 mL/min), hepatic perfusion index (%), temporal maximum intensity projection (Hounsfield units (HU)) and temporal average HU. Time-attenuation curves for seven sites (left liver lobe, right liver lobe, hepatocellular carcinoma, spleen, gastric wall, pancreas, portal vein) were obtained. Mixed-model analysis was used for statistical evaluation. Image noise and the signal:noise ratio (SNR) were compared between four reconstructions, and statistical analysis of these reconstructions was made with a related-samples Friedman’s two-way analysis of variance by ranks test. Results There were no significant differences for quantitative measurements between the four reconstructions for all tissues. There were no significant differences between the AUC values of the time-attenuation curves between the four reconstructions for all tissues, including three automatic measurements (portal vein, aorta, spleen). There was a significant difference in image noise and SNR between the four reconstructions. Conclusions ADMIRE did not affect the quantitative measurements or time-attenuation curves of tissues in the upper abdomen. The image noise was lower, and the SNR higher, for iterative reconstructions with higher noise-reduction strengths.
Collapse
Key Words
- 4D computed tomography
- ADMIRE, advanced modelled iterative reconstruction
- ALP, arterial liver perfusion
- AUC, area under the curve
- Abdomen
- BF, blood flow
- BMI, body mass index
- BV, blood volume
- CTP, computed tomography perfusion
- FBP, filtered back projection
- GFR, glomerular filtration rate
- HCC, hepatocellular carcinoma
- HPI, hepatic perfusion index
- Image reconstruction
- LI-RADS-5, liver imaging reporting and data system
- Liver
- PVP, portal venous liver perfusion
- Perfusion
- Radiation dosage
- SNR, signal to noise ratio
- TAC, time attenuation curve
- TACE, transarterial chemoembolization
- TTP, time to peak
Collapse
Affiliation(s)
- Mischa Woisetschläger
- Department of Radiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Lilian Henriksson
- Department of Radiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Wolf Bartholomae
- Department of Radiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Thomas Gasslander
- Department of Surgery in Linköping, and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Bergthor Björnsson
- Department of Surgery in Linköping, and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Per Sandström
- Department of Surgery in Linköping, and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
14
|
Tsuneta S, Oyama-Manabe N, Kameda H, Harada T, Kato F, Smit EJ, Prokop M, Kudo K. Improvement of image quality on low-dose dynamic myocardial perfusion computed tomography with a novel 4-dimensional similarity filter. Medicine (Baltimore) 2020; 99:e20804. [PMID: 32590765 PMCID: PMC7328929 DOI: 10.1097/md.0000000000020804] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
The aim of this study was to evaluate the effect of a novel 4-dimensional similarity filter (4DSF) on quantitative and qualitative parameters of low-dose dynamic myocardial computed tomography perfusion (CTP) images.In this retrospective study, medical records of 32 patients with suspected or known coronary artery disease who underwent dynamic myocardial CTP at 80 kV were included. The 4DSF reduces noise by averaging voxels that have similar dynamic behavior after adaptive iterative dose reduction 3D (AIDR3D) and deformable image registration were applied. Qualitative (artefact, contour sharpness, and myocardial homogeneity [1 = poor; 2 = intermediate; 3 = good]) and quantitative measurement (standard deviation [SD] and signal-to-noise ratio [SNR]) were compared between the 4DSF and AIDR3D. Contrast-to-noise ratio (CNR) between ischemic and normal remote myocardium was also assessed using myocardial perfusion magnetic resonance imaging as the reference standard in seven patients.The 4DSF was successfully applied to all the images. Improvement in subjective image quality yielded by 4DSF was higher than that yielded by AIDR3D (homogeneity, 1.0 [3 vs 2]; artefact, 1.5 [3 vs 1.5]; P < .001) in all patients. The 4DSF significantly decreased the SD by 59% (AIDR3D vs 4DSF: 33.5 ± 0.4 vs 13.8 ± 0.4, P < .001), increased the SNR by 134% (AIDR3D vs 4DSF: 4.4 ± 0.2 vs 10.3 ± 0.2, P < .001), and increased the CNR by 131% (AIDR3D vs 4DSF: 1.6 ± 0.2 vs 3.7 ± 0.2, P < .001).The 4DSF improved the qualitative and quantitative parameters of low-dose dynamic myocardial CTP images.
Collapse
Affiliation(s)
- Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido
- Department of Diagnostic Imaging, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido
| | - Noriko Oyama-Manabe
- Department of Radiology, Saitama Medical Center, Jichi Medical University, Saitama-shi, Saitama
| | - Hiroyuki Kameda
- Department of Dental Radiology, Hokkaido University Graduate School of Dental Medicine, Sapporo, Hokkaido, Japan
| | - Taisuke Harada
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido
| | - Fumi Kato
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido
| | - Ewoud J. Smit
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Mathias Prokop
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Kohsuke Kudo
- Department of Diagnostic Imaging, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido
| |
Collapse
|
15
|
Clinical application of four-dimensional noise reduction filtering with a similarity algorithm in dynamic myocardial computed tomography perfusion imaging. Int J Cardiovasc Imaging 2020; 36:1781-1789. [PMID: 32399762 DOI: 10.1007/s10554-020-01878-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 05/04/2020] [Indexed: 10/24/2022]
Abstract
We aimed to evaluate the effects of four-dimensional noise reduction filtering using a similarity algorithm (4D-SF) on the image quality and hemodynamic parameter of dynamic myocardial computed tomography perfusion (CTP). Sixty-eight patients who underwent dynamic myocardial CTP for the assessment of coronary artery disease were enrolled. Dynamic CTP was performed using a 320-row CT with low tube voltage scan (80 kVp). Two different datasets of dynamic CTP were reconstructed using iterative reconstruction (IR) alone and a combination of IR and 4D-SF. Qualitative (5-grade scale) and quantitative image quality scores were assessed, and the CT-derived myocardial blood flow (CT-MBF) was quantified. These results were compared between the two different CTP images. The qualitative image quality in CTP images reconstructed with IR and 4D-SF was significantly higher than that with IR alone (noise score: 4.7 vs. 3.4, p < 0.05). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in CTP images reconstructed with IR and 4D-SF were significantly higher than those with IR alone (SNR: 20.6 vs. 9.7; CNR: 7.9 vs. 3.9, respectively; p < 0.05). There was no significant difference in mean CT-MBF between the two sets of CTP images (3.01 vs. 3.03 mL/g/min, p = 0.1081). 4D-SF showed incremental value in improving image quality in combination with IR without altering CT-MBF quantification in dynamic myocardial CTP imaging with a low tube potential.
Collapse
|
16
|
I S, C A, H S, P T, T F. Comparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques. J Biomed Phys Eng 2020; 10:215-224. [PMID: 32337189 PMCID: PMC7166214 DOI: 10.31661/jbpe.v0i0.1912-1013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Accepted: 12/09/2019] [Indexed: 12/13/2022]
Abstract
Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR)
on CT scanner and its comparison to the filtered back-projection (FBP). Material and Methods: In this experimental phantom study, a TOS-phantom was scanned using a Toshiba Alexion 6 CT scanner. The images were reconstructed
using the FBP and AIDR. Measurements of HU and noise values were performed on images of the “HU linearity” module of the TOS-phantom.
The module had five embedded objects, i.e., air, polypropylene, nylon, acrylic, and Delrin. On each object, a circle area of 4.32
cm2 was drawn and used to measure HU and noise values. The R2 of the relation between mass densities vs. HU values was used to
measure HU linearities at four different tube voltages. The Mann-Whitney U test was used to compare unpaired data and p-value < 0.05 was considered statistically significant. Results: The AIDR method produced a significant smaller image noise than the FBP method (p-value < 0.05).
There were no significant differences in HU values of images reconstructed using FBP and AIDR methods (p-value > 0.05).
The HU values acquired by the methods showed the same linearity marked by coinciding linear lines with the same R2 value (> 0.999). Conclusion: AIDR methods produce the HU linearity as FBP methods with a smaller image noise level.
Collapse
Affiliation(s)
- Suyudi I
- BSc, Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Indonesia
| | - Anam C
- PhD, Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Indonesia
| | - Sutanto H
- PhD, Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Indonesia
| | - Triadyaksa P
- PhD, Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Indonesia
| | - Fujibuchi T
- PhD, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Japan
| |
Collapse
|
17
|
Kono T, Uetani T, Inoue K, Nagai T, Nishimura K, Suzuki J, Tanabe Y, Kido T, Kurata A, Mochizuki T, Ogimoto A, Okura T, Higaki J, Yamaguchi O, Ikeda S. Diagnostic accuracy of stress myocardial computed tomography perfusion imaging to detect myocardial ischemia: a comparison with coronary flow velocity reserve derived from transthoracic Doppler echocardiography. J Cardiol 2020; 76:251-258. [PMID: 32354493 DOI: 10.1016/j.jjcc.2020.03.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 03/05/2020] [Accepted: 03/06/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND Our aim was to evaluate the ability of adenosine triphosphate (ATP)-stress myocardial computed tomography perfusion (CTP) imaging to detect myocardial ischemia in the left anterior descending artery (LAD) territory, and to compare this method with coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography (TTDE). METHODS ATP-stress CTP and CFVR were performed in 50 patients with stable angina pectoris. Myocardial ischemia assessed from CTP imaging was defined as qualitative visual perfusion defects and reduced myocardial blood flow (MBF) based on quantitative assessment. A cut-off value of CFVR of 2.0 was used. RESULTS The mean CFVR was 1.9 ± 0.6 in ischemic regions by CTP, whereas it was 2.9 ± 0.8 in non-ischemic regions (p < 0.001). CTP imaging could accurately predict CFVR <2.0 with 84.0% diagnostic accuracy (94.7% sensitivity, 77.4% specificity, 72.0% positive predictive value, and 96.0% negative predictive value). When receiver operating characteristic curve analysis of the MBF data was performed to detect CFVR <2.0, the area under the curve was 0.89, and the optimal MBF cut-off value was 1.43 mL/g/min. CONCLUSIONS This study suggests that qualitative and quantitative assessment of ATP-stress CTP exhibits a good correlation with CFVR for evaluation of myocardial ischemia.
Collapse
Affiliation(s)
- Tamami Kono
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Teruyoshi Uetani
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan.
| | - Katsuji Inoue
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Takayuki Nagai
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Kazuhisa Nishimura
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Jun Suzuki
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Yuki Tanabe
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Teruhito Kido
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Akira Kurata
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Teruhito Mochizuki
- Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
| | | | - Takafumi Okura
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Jitsuo Higaki
- Department of Cardiology, South Matsuyama Hospital, Matsuyama, Japan
| | - Osamu Yamaguchi
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Shuntaro Ikeda
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan
| |
Collapse
|
18
|
Singh A, Mor-Avi V, Patel AR. The role of computed tomography myocardial perfusion imaging in clinical practice. J Cardiovasc Comput Tomogr 2020; 14:185-194. [DOI: 10.1016/j.jcct.2019.05.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Revised: 03/28/2019] [Accepted: 05/14/2019] [Indexed: 01/17/2023]
|
19
|
Society of cardiovascular computed tomography expert consensus document on myocardial computed tomography perfusion imaging. J Cardiovasc Comput Tomogr 2020; 14:87-100. [DOI: 10.1016/j.jcct.2019.10.003] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 10/15/2019] [Indexed: 01/06/2023]
|
20
|
Impact of Knowledge-Based Iterative Model Reconstruction on Image Quality and Hemodynamic Parameters in Dynamic Myocardial Computed Tomography Perfusion Using Low-Tube-Voltage Scan: A Feasibility Study. J Comput Assist Tomogr 2019; 43:811-816. [PMID: 31453979 DOI: 10.1097/rct.0000000000000914] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Knowledge-based iterative model reconstruction (IMR) yields diagnostically acceptable image quality in low-dose static computed tomography (CT). We aimed to evaluate the feasibility of IMR in dynamic myocardial computed tomography perfusion (CTP). METHODS We enrolled 24 patients who underwent stress dynamic CTP using a 256-slice CT. Images were reconstructed using filtered back projection (FBP), hybrid IR, and IMR. Image quality and hemodynamic parameters were compared among three algorithms. RESULTS Qualitative image quality and contrast-to-noise ratio were significantly higher by IMR than by FBP or hybrid IR (visual score: 4.1 vs. 3.0 and 3.5; contrast-to-noise ratio: 12.4 vs. 6.6 and 8.4; P < 0.05). No significant difference was observed among algorithms in CTP-derived myocardial blood flow (1.68 vs. 1.73 and 1.70 mL/g/min). CONCLUSIONS The use of knowledge-based iterative model reconstruction improves image quality without altering hemodynamic parameters in low-dose dynamic CTP, compared with FBP or hybrid IR.
Collapse
|
21
|
Eck BL, Muzic RF, Levi J, Wu H, Fahmi R, Li Y, Fares A, Vembar M, Dhanantwari A, Bezerra HG, Wilson DL. The role of acquisition and quantification methods in myocardial blood flow estimability for myocardial perfusion imaging CT. Phys Med Biol 2018; 63:185011. [PMID: 30113311 PMCID: PMC6264889 DOI: 10.1088/1361-6560/aadab6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In this work, we clarified the role of acquisition parameters and quantification methods in myocardial blood flow (MBF) estimability for myocardial perfusion imaging using CT (MPI-CT). We used a physiologic model with a CT simulator to generate time-attenuation curves across a range of imaging conditions, i.e. tube current-time product, imaging duration, and temporal sampling, and physiologic conditions, i.e. MBF and arterial input function width. We assessed MBF estimability by precision (interquartile range of MBF estimates) and bias (difference between median MBF estimate and reference MBF) for multiple quantification methods. Methods included: six existing model-based deconvolution models, such as the plug-flow tissue uptake model (PTU), Fermi function model, and single-compartment model (SCM); two proposed robust physiologic models (RPM1, RPM2); model-independent singular value decomposition with Tikhonov regularization determined by the L-curve criterion (LSVD); and maximum upslope (MUP). Simulations show that MBF estimability is most affected by changes in imaging duration for model-based methods and by changes in tube current-time product and sampling interval for model-independent methods. Models with three parameters, i.e. RPM1, RPM2, and SCM, gave least biased and most precise MBF estimates. The average relative bias (precision) for RPM1, RPM2, and SCM was ⩽11% (⩽10%) and the models produced high-quality MBF maps in CT simulated phantom data as well as in a porcine model of coronary artery stenosis. In terms of precision, the methods ranked best-to-worst are: RPM1 > RPM2 > Fermi > SCM > LSVD > MUP [Formula: see text] other methods. In terms of bias, the models ranked best-to-worst are: SCM > RPM2 > RPM1 > PTU > LSVD [Formula: see text] other methods. Models with four or more parameters, particularly five-parameter models, had very poor precision (as much as 310% uncertainty) and/or significant bias (as much as 493%) and were sensitive to parameter initialization, thus suggesting the presence of multiple local minima. For improved estimates of MBF from MPI-CT, it is recommended to use reduced models that incorporate prior knowledge of physiology and contrast agent uptake, such as the proposed RPM1 and RPM2 models.
Collapse
Affiliation(s)
- Brendan L Eck
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States of America
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Sugawara H, Suzuki S, Katada Y, Ishikawa T, Fukui R, Yamamoto Y, Abe O. Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages. Eur Radiol 2018; 29:1400-1407. [PMID: 30209591 DOI: 10.1007/s00330-018-5724-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Revised: 08/05/2018] [Accepted: 08/16/2018] [Indexed: 12/25/2022]
Abstract
PURPOSE To compare image quality of abdominal arteries between full-iodine-dose conventional CT and half-iodine-dose virtual monochromatic imaging (VMI). MATERIALS AND METHODS We retrospectively evaluated images of 21 patients (10 men, 11 women; mean age, 73.9 years) who underwent both full-iodine (600 mg/kg) conventional CT and half-iodine (300 mg/kg) VMI. For each patient, we measured and compared CT attenuation and the contrast-to-noise ratio (CNR) of the aorta, celiac artery, and superior mesenteric artery (SMA). We also compared CT dose index (CTDI). Two board-certified diagnostic radiologists evaluated visualisation of the main trunks and branches of the celiac artery and SMA in maximum-intensity-projection images. We evaluated spatial resolution of the two scans using an acrylic phantom. RESULTS The two scans demonstrated no significant difference in CT attenuation of the aorta, celiac artery, and SMA, but CNRs of the aorta and celiac artery were significantly higher in VMI (p = 0.011 and 0.030, respectively). CTDI was significantly higher in VMI (p = 0.024). There was no significant difference in visualisation of the main trunk of the celiac artery and SMA, but visualisation of the gastroduodenal artery, pancreatic arcade, branch of the SMA, marginal arteries, and vasa recta was significantly better in the conventional scan (p < 0.001). The calculated modular transfer function (MTF) suggested decreased spatial resolution of the half-iodine VMI. CONCLUSION Large-vessel depiction and CNRs were comparable between full-iodine conventional CT and half-iodine VMI images, but VMI did not permit clear visualisation of small arteries and required a larger radiation dose. KEY POINTS ・Reducing the dose of iodine contrast medium is essential for chronic kidney disease patients to prevent contrast-induced nephropathy. ・In virtual monochromatic images at low keV, contrast of relatively large vessels is maintained even with reduced iodine load, but visibility of small vessels is impaired with decreased spatial resolution. ・We should be aware about the advantages and disadvantages associated with virtual monochromatic imaging with reduced iodine dose.
Collapse
Affiliation(s)
- Haruto Sugawara
- Department of Radiology, Tokyo Women's Medical University Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo, 116-8567, Japan.,Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Shigeru Suzuki
- Department of Radiology, Tokyo Women's Medical University Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo, 116-8567, Japan.
| | - Yoshiaki Katada
- Department of Radiology, Tokyo Women's Medical University Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo, 116-8567, Japan
| | - Takuya Ishikawa
- Department of Radiology, Tokyo Women's Medical University Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo, 116-8567, Japan
| | - Rika Fukui
- Department of Radiology, Tokyo Women's Medical University Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo, 116-8567, Japan
| | - Yuzo Yamamoto
- Department of Radiology, Tokyo Women's Medical University Medical Center East, 2-1-10 Nishiogu, Arakawa-ku, Tokyo, 116-8567, Japan
| | - Osamu Abe
- Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| |
Collapse
|
23
|
Bian Z, Zeng D, Zhang Z, Gong C, Tian X, Yan G, Huang J, Guo H, Chen B, Zhang J, Feng Q, Chen W, Ma J. Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior. Med Phys 2018; 44:e188-e201. [PMID: 28901610 DOI: 10.1002/mp.12285] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 02/20/2017] [Accepted: 04/09/2017] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated scanning. To address this issue, in this work, we developed a statistical iterative reconstruction algorithm based on the penalized weighted least-squares (PWLS) scheme by incorporating a motion adaptive sparsity prior (MASP) model to achieve high-quality DM-PCT imaging with low tube current dynamic data acquisition. For simplicity, we refer to the proposed algorithm as "PWLS-MASP''. METHODS The MASP models both the spatial and temporal structured sparsity of DM-PCT sequence images with the assumption that the differences between adjacent frames after motion correction are sparse in the gradient image domain. To validate and evaluate the effectiveness of the present PWLS-MASP algorithm thoroughly, a modified XCAT phantom and preclinical porcine DM-PCT dataset were used in the study. RESULTS The present PWLS-MASP algorithm can obtain high-quality DM-PCT images in both phantom and porcine cases, and outperforms the existing filtered back-projection algorithm and PWLS-based algorithms with total variation regularization (PWLS-TV) and robust principal component analysis regularization (PWLS-RPCA) in terms of noise reduction, streak artifacts mitigation, and time density curve estimation. Moreover, the PWLS-MASP algorithm can yield more accurate diagnostic hemodynamic parametric maps than the PWLS-TV and PWLS-RPCA algorithms. CONCLUSIONS The study indicates that there is a substantial advantage in using the present PWLS-MASP algorithm for low-dose DM-PCT, and potentially in other dynamic tomography areas.
Collapse
Affiliation(s)
- Zhaoying Bian
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| | - Dong Zeng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| | - Zhang Zhang
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Changfei Gong
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| | - Xiumei Tian
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| | - Gang Yan
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| | - Jing Huang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| | - Hong Guo
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Bo Chen
- College of Mathematics and Statistics, Shenzhen University, Shenzhen, 518060, China
| | - Jing Zhang
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Qianjin Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| | - Wufan Chen
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| | - Jianhua Ma
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, 510515, China.,Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, 510515, China
| |
Collapse
|
24
|
Zhang J, Liu X, Knopp MI, Ramaswamy B, Knopp MV. How Long of a Dynamic 3'-Deoxy-3'-[ 18F]fluorothymidine ([ 18F]FLT) PET Acquisition Is Needed for Robust Kinetic Analysis in Breast Cancer? Mol Imaging Biol 2018; 21:382-390. [PMID: 29987617 DOI: 10.1007/s11307-018-1231-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
PURPOSE To quantitatively evaluate the minimally required scanning time of 3'-deoxy-3'-[18F]fluorothymidine ([18F]FLT) positron emission tomography (PET) dynamic acquisition for accurate kinetic assessment of the proliferation in breast cancer tumors. PROCEDURES Within a therapeutic intervention trial, 26 breast tumors of 8 breast cancer patients were analyzed from 30-min dynamic [18F]FLT-PET acquisitions. PET/CT was acquired on a Gemini TF 64 system (Philips Healthcare) and reconstructed into 26 frames (8 × 15 s, 6 × 30 s, 5 × 1 min, 5 × 2 min, and 2 × 5 min). Maximum activity concentrations (Bq/ml) of volume of interests over tumors and plasma in descending aorta were obtained over time frames. Kinetic parameters were estimated using in-house developed software with the two-tissue three-compartment irreversible model (2TCM) (K1, k2, k3, and Ki; k4 = 0) and Patlak model (Ki) based on different acquisition durations (Td) (10, 12, 14, 16, 20, 25, and 30 min, separately). Different linear regression onset time (T0) points (1, 2, 3, 4, and 5 min) were applied in Patlak analysis. Ki of the 30-min data set was taken as the gold standard for comparison. Pearson product-moment correlation coefficient (R) of 0.9 was chosen as a limit for the correlation. RESULTS The correlation of kinetic parameters between the gold standard and the abbreviated dynamic data series increased with longer Td from 10 to 30 min. k2 and k3 using 2TCM and Ki using Patlak model revealed poor correlations for dynamic PET with Td ≤ 14 min (k2: R = 0.84, 0.85, 0.86; k3: R = 0.67, 0.67, 0.67; Ki: R = 0.72, 0.78, 0.87 at Td = 10, 12, and 14 min, respectively). Excellent correlations were shown for all kinetic parameters when Td ≥ 16 min regardless of the kinetic model and T0 value (R > 0.9). CONCLUSIONS This study indicates that a 16-min dynamic PET acquisition appears to be sufficient to provide accurate [18F]FLT kinetics to quantitatively assess the proliferation in breast cancer lesions.
Collapse
Affiliation(s)
- Jun Zhang
- Wright Center of Innovation in Biomedical Imaging, Department of Radiology, The Ohio State University Wexner Medical Center, 395 W. 12th Avenue, Room 430, Columbus, OH, 43210-1228, USA
| | - Xiaoli Liu
- Wright Center of Innovation in Biomedical Imaging, Department of Radiology, The Ohio State University Wexner Medical Center, 395 W. 12th Avenue, Room 430, Columbus, OH, 43210-1228, USA
| | - Michelle I Knopp
- Wright Center of Innovation in Biomedical Imaging, Department of Radiology, The Ohio State University Wexner Medical Center, 395 W. 12th Avenue, Room 430, Columbus, OH, 43210-1228, USA
| | - Bhuvaneswari Ramaswamy
- Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA
| | - Michael V Knopp
- Wright Center of Innovation in Biomedical Imaging, Department of Radiology, The Ohio State University Wexner Medical Center, 395 W. 12th Avenue, Room 430, Columbus, OH, 43210-1228, USA.
| |
Collapse
|
25
|
Lu L, Ma X, Mohy-Ud-Din H, Ma J, Feng Q, Rahmim A, Chen W. Enhancement of dynamic myocardial perfusion PET images based on low-rank plus sparse decomposition. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 154:57-69. [PMID: 29249347 DOI: 10.1016/j.cmpb.2017.10.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2017] [Revised: 08/30/2017] [Accepted: 10/16/2017] [Indexed: 06/07/2023]
Abstract
BACKGROUND AND OBJECTIVE The absolute quantification of dynamic myocardial perfusion (MP) PET imaging is challenged by the limited spatial resolution of individual frame images due to division of the data into shorter frames. This study aims to develop a method for restoration and enhancement of dynamic PET images. METHODS We propose that the image restoration model should be based on multiple constraints rather than a single constraint, given the fact that the image characteristic is hardly described by a single constraint alone. At the same time, it may be possible, but not optimal, to regularize the image with multiple constraints simultaneously. Fortunately, MP PET images can be decomposed into a superposition of background vs. dynamic components via low-rank plus sparse (L + S) decomposition. Thus, we propose an L + S decomposition based MP PET image restoration model and express it as a convex optimization problem. An iterative soft thresholding algorithm was developed to solve the problem. Using realistic dynamic 82Rb MP PET scan data, we optimized and compared its performance with other restoration methods. RESULTS The proposed method resulted in substantial visual as well as quantitative accuracy improvements in terms of noise versus bias performance, as demonstrated in extensive 82Rb MP PET simulations. In particular, the myocardium defect in the MP PET images had improved visual as well as contrast versus noise tradeoff. The proposed algorithm was also applied on an 8-min clinical cardiac 82Rb MP PET study performed on the GE Discovery PET/CT, and demonstrated improved quantitative accuracy (CNR and SNR) compared to other algorithms. CONCLUSIONS The proposed method is effective for restoration and enhancement of dynamic PET images.
Collapse
Affiliation(s)
- Lijun Lu
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong 510515, China.
| | - Xiaomian Ma
- School of Software, Guangdong Food and Drug Vocational College, Guangzhou, Guangdong 510520, China
| | - Hassan Mohy-Ud-Din
- Shaukat Khanum Memorial Cancer Hospital and Research Center, Lahore, Pakistan
| | - Jianhua Ma
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong 510515, China
| | - Qianjin Feng
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong 510515, China.
| | - Arman Rahmim
- Department of Radiology, Johns Hopkins University, Baltimore, MD 21287, USA; Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Wufan Chen
- School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong 510515, China.
| |
Collapse
|
26
|
Kitagawa K, Goto Y, Nakamura S, Takafuji M, Hamdy A, Ishida M, Sakuma H. Dynamic CT Perfusion Imaging: State of the Art. ACTA ACUST UNITED AC 2018. [DOI: 10.22468/cvia.2018.00031] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Kakuya Kitagawa
- Department of Radiology, Mie University School of Medicine, Tsu, Japan
| | - Yoshitaka Goto
- Department of Radiology, Mie University School of Medicine, Tsu, Japan
| | - Satoshi Nakamura
- Department of Radiology, Mie University School of Medicine, Tsu, Japan
| | - Masafumi Takafuji
- Department of Radiology, Mie University School of Medicine, Tsu, Japan
| | - Ahmed Hamdy
- Department of Radiology, Mie University School of Medicine, Tsu, Japan
| | - Masaki Ishida
- Department of Radiology, Mie University School of Medicine, Tsu, Japan
| | - Hajime Sakuma
- Department of Radiology, Mie University School of Medicine, Tsu, Japan
| |
Collapse
|
27
|
Halliburton SS, Tanabe Y, Partovi S, Rajiah P. The role of advanced reconstruction algorithms in cardiac CT. Cardiovasc Diagn Ther 2017; 7:527-538. [PMID: 29255694 DOI: 10.21037/cdt.2017.08.12] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Non-linear iterative reconstruction (IR) algorithms have been increasingly incorporated into clinical cardiac CT protocols at institutions around the world. Multiple IR algorithms are available commercially from various vendors. IR algorithms decrease image noise and are primarily used to enable lower radiation dose protocols. IR can also be used to improve image quality for imaging of obese patients, coronary atherosclerotic plaques, coronary stents, and myocardial perfusion. In this article, we will review the various applications of IR algorithms in cardiac imaging and evaluate how they have changed practice.
Collapse
Affiliation(s)
| | - Yuki Tanabe
- Cardiothoracic Imaging, Radiology Department, UT Southwestern Medical Center, Dallas, TX, USA
| | - Sasan Partovi
- University Hospitals Cleveland Medical Center, Cleveland, OH, USA
| | - Prabhakar Rajiah
- Cardiothoracic Imaging, Radiology Department, UT Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
28
|
Tanabe Y, Kido T, Kurata A, Yokoi T, Fukuyama N, Uetani T, Nishiyama H, Kawaguchi N, Tahir E, Miyagawa M, Mochizuki T. Peak enhancement ratio of myocardium to aorta for identification of myocardial ischemia using dynamic myocardial computed tomography perfusion imaging. J Cardiol 2017; 70:565-570. [PMID: 28501269 DOI: 10.1016/j.jjcc.2017.04.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Revised: 03/24/2017] [Accepted: 04/05/2017] [Indexed: 10/19/2022]
Abstract
BACKGROUND This study aimed to evaluate the feasibility of peak enhancement (PE) ratio of myocardium to aorta (PER) derived from stress dynamic computed tomography myocardial perfusion imaging (CTP) for the detection of myocardial ischemia assessed by magnetic resonance (MR) imaging. METHODS Forty-four patients who underwent stress dynamic CTP and MR imaging were retrospectively evaluated. From the time-attenuation curve, myocardial PE, PER, and myocardial blood flow (MBF) were calculated on a segment-based analysis. The correlation between myocardial and aortic PE was assessed by Spearman's correlation, and the differences in myocardial PE and PER between normal and ischemic myocardium were assessed by the Mann-Whitney U-test. The diagnostic accuracies of myocardial PE, PER, and MBF for detecting myocardial ischemia were compared by receiver operating characteristic analysis. RESULTS Of 704 segments, 258 segments (37%) were diagnosed as myocardial ischemia with MR imaging. Myocardial and aortic PE were significantly correlated in both normal and ischemic segments (r=0.76 and 0.58; p<0.05, in each). The myocardial PE and PER of ischemic segments were significantly lower than those of normal segments (p<0.05, in each). Sensitivity and specificity were 61% [95% confidence interval (CI), 55-70%] and 83% (95% CI, 73-87%) for myocardial PE, 78% (67-88%) and 82% (95% CI, 70-91%) for PER, and 81% (95% CI, 73-87%) and 85% (95% CI, 79-92%) for MBF. There was a significantly larger area under the curve for PER (0.87; 95% CI, 0.84-0.90) and MBF (0.88; 95%CI, 0.85-0.91), compared to myocardial PE (0.75; 95% CI, 0.70-0.79) (p<0.05, in each). There was no significant difference in area under the curve between PER and MBF. CONCLUSIONS The semi-quantitative parameter of PER showed a high diagnostic accuracy for the detection of myocardial ischemia, comparable to that of MBF.
Collapse
Affiliation(s)
- Yuki Tanabe
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan.
| | - Teruhito Kido
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| | - Akira Kurata
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| | - Takahiro Yokoi
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| | - Naoki Fukuyama
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| | - Teruyoshi Uetani
- Department of Cardiovascular Internal Medicine, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| | - Hikaru Nishiyama
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| | - Naoto Kawaguchi
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| | - Enver Tahir
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Masao Miyagawa
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| | - Teruhito Mochizuki
- Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon City, Ehime, Japan
| |
Collapse
|
29
|
Impact of knowledge-based iterative model reconstruction on myocardial late iodine enhancement in computed tomography and comparison with cardiac magnetic resonance. Int J Cardiovasc Imaging 2017; 33:1609-1618. [DOI: 10.1007/s10554-017-1137-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Accepted: 04/08/2017] [Indexed: 01/08/2023]
|
30
|
Gong C, Han C, Gan G, Deng Z, Zhou Y, Yi J, Zheng X, Xie C, Jin X. Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization. Phys Med Biol 2017; 62:2612-2635. [PMID: 28140366 DOI: 10.1088/1361-6560/aa5d40] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Dynamic myocardial perfusion CT (DMP-CT) imaging provides quantitative functional information for diagnosis and risk stratification of coronary artery disease by calculating myocardial perfusion hemodynamic parameter (MPHP) maps. However, the level of radiation delivered by dynamic sequential scan protocol can be potentially high. The purpose of this work is to develop a pre-contrast normal-dose scan induced structure tensor total variation regularization based on the penalized weighted least-squares (PWLS) criteria to improve the image quality of DMP-CT with a low-mAs CT acquisition. For simplicity, the present approach was termed as 'PWLS-ndiSTV'. Specifically, the ndiSTV regularization takes into account the spatial-temporal structure information of DMP-CT data and further exploits the higher order derivatives of the objective images to enhance denoising performance. Subsequently, an effective optimization algorithm based on the split-Bregman approach was adopted to minimize the associative objective function. Evaluations with modified dynamic XCAT phantom and preclinical porcine datasets have demonstrated that the proposed PWLS-ndiSTV approach can achieve promising gains over other existing approaches in terms of noise-induced artifacts mitigation, edge details preservation, and accurate MPHP maps calculation.
Collapse
Affiliation(s)
- Changfei Gong
- Department of Radiotherapy and Chemotherapy, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Temporal averaging for analysis of four-dimensional whole-heart computed tomography perfusion of the myocardium: proof-of-concept study. Int J Cardiovasc Imaging 2016; 33:371-382. [PMID: 27832419 DOI: 10.1007/s10554-016-1011-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Accepted: 10/25/2016] [Indexed: 01/03/2023]
Abstract
To assess the feasibility of four-dimensional (4D) whole-heart computed tomography perfusion (CTP) of the myocardium and the added value of temporal averaging of consecutive 3D datasets from different heartbeats for analysis. We included 30 patients with suspected or known coronary artery disease (CAD) who underwent 320-row coronary CT angiography (CTA) and myocardial CTP. Out of these, 15 patients underwent magnetic resonance myocardial perfusion imaging (MR MPI). All CTP examinations were initiated after 3 min of intravenous infusion of adenosine (140 µg/kg/min) and were performed dynamically covering the entire heart every heart beat over a period of 20 ± 3 heart beats. Temporal averaging for dynamic CTP visualisation was analysed for the combination of two, three, four, six, and eight consecutive 3D datasets. Input time attenuation curves (TAC) were delivered from measurement points in the centre of the left ventricle. In all 30 patients, myocardial 4D CTP was feasible and temporal averaging was successfully implemented for all planned combinations of 3D datasets. Temporal averaging of three consecutive 3D datasets showed best performance in the analysis of all CTP image quality parameters: noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image quality, and diagnostic accuracy with an improvement of SNR and CNR by a factor of 2.2 ± 1.3 and 1.3 ± 0.9. With increasing level of temporal averaging, the input TACs became smoother, but also shorter. Out of the 11 perfusion defects detected with MR MPI, 9 defects were also visible on the 4D CTP images. Whole-heart CTP of the myocardium is feasible and temporal averaging of dynamic datasets improves quantitative image quality parameters and visualization of perfusion defects while further studies are needed to assess its added value for quantification of perfusion parameters.
Collapse
|
32
|
Rui X, Jin Y, FitzGerald PF, Wu M, Alessio AM, Kinahan PE, De Man B. Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction. Phys Med Biol 2016; 61:7787-7811. [PMID: 27754977 DOI: 10.1088/0031-9155/61/21/7787] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Computed tomography (CT) has been used for a variety of applications, two of which include diagnostic imaging and attenuation correction for PET or SPECT imaging. Ideally, the x-ray tube spectrum should be optimized for the specific application to minimize the patient radiation dose while still providing the necessary information. In this study, we proposed a projection-based analytic approach for the analysis of contrast, noise, and bias. Dose normalized contrast to noise ratio (CNRD), inverse noise normalized by dose (IND) and bias are used as evaluation metrics to determine the optimal x-ray spectrum. Our simulation investigated the dose efficiency of the x-ray spectrum ranging from 40 kVp to 200 kVp. Water cylinders with diameters of 15 cm, 24 cm, and 35 cm were used in the simulation to cover a variety of patient sizes. The effects of electronic noise and pre-patient copper filtration were also evaluated. A customized 24 cm CTDI-like phantom with 13 mm diameter inserts filled with iodine (10 mg ml-1), tantalum (10 mg ml-1), water, and PMMA was measured with both standard (1.5 mGy) and ultra-low (0.2 mGy) dose to verify the simulation results at tube voltages of 80, 100, 120, and 140 kVp. For contrast-enhanced diagnostic imaging, the simulation results indicated that for high dose without filtration, the optimal kVp for water contrast is approximately 100 kVp for a 15 cm water cylinder. However, the 60 kVp spectrum produces the highest CNRD for bone and iodine. The optimal kVp for tantalum has two selections: approximately 50 and 100 kVp. The kVp that maximizes CNRD increases when the object size increases. The trend in the CTDI phantom measurements agrees with the simulation results, which also agrees with previous studies. Copper filtration improved the dose efficiency for water and tantalum, but reduced the iodine and bone dose efficiency in a clinically-relevant range (70-140 kVp). Our study also shows that for CT-based attenuation correction applications for PET or SPECT, a higher-kVp spectrum with copper filtration is preferable. This method is developed based on filter back projection and does not require image reconstruction or Monte Carlo dose estimates; thus, it could potentially be used for patient-specific and task-based on-the-fly protocol optimization.
Collapse
Affiliation(s)
- Xue Rui
- Image Reconstruction Laboratory, GE Global Research Center, Niskayuna, NY, USA
| | | | | | | | | | | | | |
Collapse
|
33
|
Li M, Zhao Y, Zhang P. Attenuator design method for dedicated whole-core CT. OPTICS EXPRESS 2016; 24:22749-22765. [PMID: 27828346 DOI: 10.1364/oe.24.022749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In whole-core CT imaging, scanned data corresponding to the central portion of a cylindrical core often suffer from photon starvation, because increasing photon flux will cause overflow on some detector units under the restriction of detector dynamic range. Either photon starvation or data overflow will lead to increased noise or severe artifacts in the reconstructed CT image. In addition, cupping shaped beam hardening artifacts also appear in the whole-core CT image. In this paper, we present a method to design an attenuator for cone beam whole-core CT, which not only reduces the dynamic range requirement for high SNR data scanning, but also corrects beam hardening artifacts. Both simulation and real data are employed to verify our design method.
Collapse
|
34
|
Abstract
PURPOSE OF REVIEW Computed tomography (CT) coronary angiography is a well-validated non-invasive technique for accurate and expedient diagnosis of coronary artery disease (CAD). However, a limitation of coronary CT angiography (CCTA) is its limited capability to identify physiologically significant stenoses, which may eventuate the need for further functional testing. Stress CT myocardial perfusion imaging (CT-MPI) is an emerging technique that has the ability to identify flow-limiting stenoses. RECENT FINDINGS The combination of CCTA coronary and CT-MPI has transformed the modality from a tool to assess anatomy and morphology to a modality capable of simultaneous assessment of coronary stenoses and their physiologic significance. A growing number of studies have demonstrated the feasibility and diagnostic accuracy of CT-MPI in comparison to a number of reference standard modalities for CAD diagnosis, including single-photon emission CT, cardiovascular magnetic resonance imaging, and invasive coronary angiography with and without fractional flow-reserve testing. SUMMARY While there is still a need for consensus regarding acquisition techniques as well as analysis and interpretation of CT-MPI, with further validation, it is likely to become a powerful adjunctive tool to CCTA in the management of patients with suspected coronary disease.
Collapse
|
35
|
Christianson O, Chen JJS, Yang Z, Saiprasad G, Dima A, Filliben JJ, Peskin A, Trimble C, Siegel EL, Samei E. An Improved Index of Image Quality for Task-based Performance of CT Iterative Reconstruction across Three Commercial Implementations. Radiology 2015; 275:725-34. [DOI: 10.1148/radiol.15132091] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
36
|
Zhao L, Plank F, Kummann M, Burghard P, Klauser A, Dichtl W, Feuchtner G. Improved non-calcified plaque delineation on coronary CT angiography by sonogram-affirmed iterative reconstruction with different filter strength and relationship with BMI. Cardiovasc Diagn Ther 2015; 5:104-12. [PMID: 25984450 DOI: 10.3978/j.issn.2223-3652.2015.03.06] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Accepted: 03/13/2015] [Indexed: 01/25/2023]
Abstract
PURPOSE To prospectively compare non-calcified plaque delineation and image quality of coronary computed tomography angiography (CCTA) obtained with sinogram-affirmed iterative reconstruction (IR) with different filter strengths and filtered back projection (FBP). METHODS A total of 57 patients [28.1% females; body mass index (BMI) 29.2±6.5 kg/m(2)] were investigated. CCTA was performed using 128-slice dual-source CT. Images were reconstructed with standard FBP and sinogram-affirmed IR using different filter strength (IR-2, IR-3, IR-4) (SAFIRE, Siemens, Germany). Image quality of CCTA and a non-calcified plaque outer border delineation score were evaluated by using a 5-scale score: from 1= poor to 5= excellent. Image noise, contrast-to-noise ratio (CNR) of aortic root, left main (LM) and right coronary artery, and the non-calcified plaque delineation were quantified and compared among the 4 image reconstructions, and were compared between different BMI groups (BMI <28 and ≥28). Statistical analyses included one-way analysis of variance (ANOVA), least significant difference (LSD) and Kruskal-Wallis test. RESULTS There were 71.9% patients in FBP, 96.5% in IR-2, 96.5% in IR-3 and 98.2% in IR-4 who had overall CCTA image quality ≥3, and there were statistical differences in CCTA exam image quality score among those groups, respectively (P<0.001). Sixty-one non-calcified plaques were detected by IR-2 to IR-4, out of those 11 (18%) were missed by FBP. Plaque delineation score increased constantly from FBP (2.7±0.4) to IR-2 (3.2±0.3), to IR-3 (3.5±0.3) up to IR-4 (4.0±0.4), while CNRs of the non-calcifying plaque increased and image noise decreased, respectively. Similarly, CNR of aortic root, LM and right coronary artery improved and image noise declined from FBP to IR-2, IR-3 and IR-4. There were no significant differences of image quality and plaque delineation score between low and high BMI groups within same reconstruction (all P>0.05). Significant differences in image quality and plaque delineation scores among different image reconstructions both in low and high BMI groups (all P<0.001) were found. I4f revealed the highest image quality and plaque delineation score. CONCLUSIONS IR offers improved image quality and non-calcified plaque delineation as compared with FBP, especially if BMI is increasing. Importantly, 18% of non-calcified plaques were missed with FBP. IR-4 shows the best image quality score and plaque delineation score among the different IR-filter strength.
Collapse
Affiliation(s)
- Lei Zhao
- 1 Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Chaoyang District, Beijing 100029, China ; 2 Innsbruck Medical University, Department of Radiology, 3 Innsbruck Medical University, Department of Cardiology, Innrain 52, Christoph-Probst-Platz, 6020 Innsbruck, Tyrol, Austria
| | - Fabian Plank
- 1 Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Chaoyang District, Beijing 100029, China ; 2 Innsbruck Medical University, Department of Radiology, 3 Innsbruck Medical University, Department of Cardiology, Innrain 52, Christoph-Probst-Platz, 6020 Innsbruck, Tyrol, Austria
| | - Moritz Kummann
- 1 Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Chaoyang District, Beijing 100029, China ; 2 Innsbruck Medical University, Department of Radiology, 3 Innsbruck Medical University, Department of Cardiology, Innrain 52, Christoph-Probst-Platz, 6020 Innsbruck, Tyrol, Austria
| | - Philipp Burghard
- 1 Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Chaoyang District, Beijing 100029, China ; 2 Innsbruck Medical University, Department of Radiology, 3 Innsbruck Medical University, Department of Cardiology, Innrain 52, Christoph-Probst-Platz, 6020 Innsbruck, Tyrol, Austria
| | - Andrea Klauser
- 1 Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Chaoyang District, Beijing 100029, China ; 2 Innsbruck Medical University, Department of Radiology, 3 Innsbruck Medical University, Department of Cardiology, Innrain 52, Christoph-Probst-Platz, 6020 Innsbruck, Tyrol, Austria
| | - Wolfgang Dichtl
- 1 Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Chaoyang District, Beijing 100029, China ; 2 Innsbruck Medical University, Department of Radiology, 3 Innsbruck Medical University, Department of Cardiology, Innrain 52, Christoph-Probst-Platz, 6020 Innsbruck, Tyrol, Austria
| | - Gudrun Feuchtner
- 1 Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Chaoyang District, Beijing 100029, China ; 2 Innsbruck Medical University, Department of Radiology, 3 Innsbruck Medical University, Department of Cardiology, Innrain 52, Christoph-Probst-Platz, 6020 Innsbruck, Tyrol, Austria
| |
Collapse
|
37
|
Baskan O, Erol C, Ozbek H, Paksoy Y. Effect of radiation dose reduction on image quality in adult head CT with noise-suppressing reconstruction system with a 256 slice MDCT. J Appl Clin Med Phys 2015; 16:5360. [PMID: 26103494 PMCID: PMC5690139 DOI: 10.1120/jacmp.v16i3.5360] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Revised: 01/23/2015] [Accepted: 01/21/2015] [Indexed: 11/23/2022] Open
Abstract
The purpose of our study was to investigate the effect of iterative reconstruction (IR) as a dose reduction system on the image quality (IQ) of the adult head computed tomography (CT) at various low‐dose levels, and to identify ways of setting the amount of dose reduction. We performed two noncontrast low‐dose (LD) adult head CT protocols modified by lowering the tube current with IR which were decided in the light of a group of phantom studies. Two groups of patients, each 100 underwent noncontrast head CT with LD‐I and LD‐II, respectively. These groups were compared with 100 consecutive standard dose (STD) adult head CT protocol in terms of quantitative and qualitative IQ. The signal‐to‐noise ratio (SNR) of the white matter (WM) and gray matter (GM) and contrast‐to‐noise ratio (CNR) values in the LD groups were higher than the STD group. The differences were statistically significant. When the STD and the LD groups were compared qualitatively, no significant differences were found in overall quality. By selecting the appropriate level of IR 34%, radiation dose reduction in adult head CT can be achieved without compromising IQ. PACS number: 87.57.‐s
Collapse
|
38
|
Iterative reconstruction in cardiac CT. J Cardiovasc Comput Tomogr 2015; 9:255-63. [PMID: 26088375 DOI: 10.1016/j.jcct.2015.04.004] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Revised: 04/15/2015] [Accepted: 04/15/2015] [Indexed: 12/29/2022]
Abstract
Iterative reconstruction (IR) has the ability to reduce image noise in CT without compromising diagnostic quality, which permits a significant reduction in effective radiation dose. This been increasingly integrated into clinical CT practice over the past 7 years and has been particularly important in the field of cardiac CT with multiple vendors introducing cardiac CT-compatible IR algorithms. The following review will summarize the principles of IR algorithms, studies validating their noise- and dose-reducing abilities, and the specific applications of IR in cardiac CT.
Collapse
|
39
|
Li L, Chen Z, Cong W, Wang G. Spectral CT modeling and reconstruction with hybrid detectors in dynamic-threshold-based counting and integrating modes. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:716-728. [PMID: 25252279 DOI: 10.1109/tmi.2014.2359241] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Spectral CT with photon counting detectors can significantly improve CT performance by reducing image noise and dose, increasing contrast resolution and material specificity, as well as enabling functional and molecular imaging with existing and emerging probes. However, the current photon counting detector architecture is difficult to balance the number of energy bins and the statistical noise in each energy bin. Moreover, the hardware support for multi-energy bins demands a complex circuit which is expensive. In this paper, we promote a new scheme known as hybrid detectors that combine the dynamic-threshold-based counting and integrating modes. In this scheme, an energy threshold can be dynamically changed during a spectral CT scan, which can be considered as compressive sensing along the spectral dimension. By doing so, the number of energy bins can be retrospectively specified, even in a spatially varying fashion. To establish the feasibility and merits of such hybrid detectors, we develop a tensor-based PRISM algorithm to reconstruct a spectral CT image from dynamic dual-energy data, and perform experiments with simulated and real data, producing very promising results.
Collapse
|
40
|
Park JB, Koo BK. Noninvasive hemodynamic assessment using coronary computed tomography angiography: the present and future. Interv Cardiol 2015. [DOI: 10.2217/ica.14.65] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
41
|
Fahmi R, Eck BL, Fares A, Levi J, Wu H, Vembar M, Dhanantwari A, Bezerra HG, Wilson DL. Dynamic Myocardial Perfusion in a Porcine Balloon-induced Ischemia Model using a Prototype Spectral Detector CT. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2015; 9417:94170Y. [PMID: 31942087 PMCID: PMC6961835 DOI: 10.1117/12.2081547] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Myocardial CT perfusion (CTP) imaging is an application that should greatly benefit from spectral CT through the significant reduction of beam hardening (BH) artifacts using mono-energetic (monoE) image reconstructions. We used a prototype spectral detector CT (SDCT) scanner (Philips Healthcare) and developed advanced processing tools (registration, segmentation, and deconvolution-based flow estimation) for quantitative myocardial CTP in a porcine ischemia model with different degrees of coronary occlusion using a balloon catheter. The occlusion severity was adjusted with fractional flow reserve (FFR) measurements. The SDCT scanner is a single source, dual-layer detector system, which allows simultaneous acquisitions of low and high energy projections, hence enabling accurate projection-based material decomposition and effective reduction of BH-artifacts. In addition, the SDCT scanner eliminates partial scan artifacts with fast (0.27s), full gantry rotation acquisitions. We acquired CTP data under different hemodynamic conditions and reconstructed conventional 120kVp images and projection-based monoenergetic (monoE) images for energies ranging from 55keV-to-120keV. We computed and compared myocardial blood flow (MBF) between different reconstructions. With balloon completely deflated (FFR=1), we compared the mean attenuation in a myocardial region of interest before iodine arrival and at peak iodine enhancement in the left ventricle (LV), and we found that monoE images at 70keV effectively minimized the difference in attenuation, due to BH, to less than 1 HU compared to 14 HU with conventional 120kVp images. Flow maps under baseline condition (FFR=1) were more uniform throughout the myocardial wall at 70keV, whereas with 120kVp data about 12% reduction in blood flow was noticed on BH-hypoattenuated areas compared to other myocardial regions. We compared MBF maps at different keVs under an ischemic condition (FFR < 0.7), and we found that flow-contrast-to-noise-ratio (CNR f ) between LAD ischemic and remote healthy territories attains its maximum (2.87 ± 0.7) at 70keV. As energies diverge from 70keV, we noticed a steady decrease in CNRf and an overestimation of mean-MBF. Flow overestimation was also noticed for conventional 120kVp images in different myocardial regions.
Collapse
Affiliation(s)
- Rachid Fahmi
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Brendan L Eck
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Anas Fares
- Cardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Case Medical Center, Cleveland, OH, 44106, USA
| | - Jacob Levi
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Hao Wu
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Mani Vembar
- Philips Healthcare, Cleveland, OH, 44143, USA
| | | | - Hiram G Bezerra
- Cardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Case Medical Center, Cleveland, OH, 44106, USA
| | - David L Wilson
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, 44106, USA
- Department of Radiology, Case Western Reserve University, Cleveland, OH, 44106, USA
| |
Collapse
|
42
|
Gaddikeri S, Andre JB, Benjert J, Hippe DS, Anzai Y. Impact of model-based iterative reconstruction on image quality of contrast-enhanced neck CT. AJNR Am J Neuroradiol 2015; 36:391-6. [PMID: 25300982 DOI: 10.3174/ajnr.a4123] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Improved image quality is clinically desired for contrast-enhanced CT of the neck. We compared 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction algorithms for the assessment of image quality of contrast-enhanced CT of the neck. MATERIALS AND METHODS Neck contrast-enhanced CT data from 64 consecutive patients were reconstructed retrospectively by using 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction. Objective image quality was assessed by comparing SNR, contrast-to-noise ratio, and background noise at levels 1 (mandible) and 2 (superior mediastinum). Two independent blinded readers subjectively graded the image quality on a scale of 1-5, (grade 5 = excellent image quality without artifacts and grade 1 = nondiagnostic image quality with significant artifacts). The percentage of agreement and disagreement between the 2 readers was assessed. RESULTS Compared with 30% adaptive statistical iterative reconstruction, model-based iterative reconstruction significantly improved the SNR and contrast-to-noise ratio at levels 1 and 2. Model-based iterative reconstruction also decreased background noise at level 1 (P = .016), though there was no difference at level 2 (P = .61). Model-based iterative reconstruction was scored higher than 30% adaptive statistical iterative reconstruction by both reviewers at the nasopharynx (P < .001) and oropharynx (P < .001) and for overall image quality (P < .001) and was scored lower at the vocal cords (P < .001) and sternoclavicular junction (P < .001), due to artifacts related to thyroid shielding that were specific for model-based iterative reconstruction. CONCLUSIONS Model-based iterative reconstruction offers improved subjective and objective image quality as evidenced by a higher SNR and contrast-to-noise ratio and lower background noise within the same dataset for contrast-enhanced neck CT. Model-based iterative reconstruction has the potential to reduce the radiation dose while maintaining the image quality, with a minor downside being prominent artifacts related to thyroid shield use on model-based iterative reconstruction.
Collapse
Affiliation(s)
- S Gaddikeri
- From the Department of Neuroradiology (S.G., J.B.A., Y.A.), University of Washington Medical Center, University of Washington, Seattle, Washington
| | - J B Andre
- From the Department of Neuroradiology (S.G., J.B.A., Y.A.), University of Washington Medical Center, University of Washington, Seattle, Washington
| | - J Benjert
- Department of Neuroradiology (J.B.), University of Washington and VA Puget Sound, Seattle, Washington
| | - D S Hippe
- Department of Radiology (D.S.H.), University of Washington, Seattle, Washington
| | - Y Anzai
- From the Department of Neuroradiology (S.G., J.B.A., Y.A.), University of Washington Medical Center, University of Washington, Seattle, Washington
| |
Collapse
|
43
|
Eck BL, Fahmi R, Fuqua C, Vembar M, Dhanantwari A, Bezerra HG, Wilson DL. Low dose dynamic myocardial CT perfusion using advanced iterative reconstruction. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2015; 9417:94170Z. [PMID: 32210494 PMCID: PMC7093059 DOI: 10.1117/12.2081418] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Dynamic myocardial CT perfusion (CTP) can provide quantitative functional information for the assessment of coronary artery disease. However, x-ray dose in dynamic CTP is high, typically from 10mSv to >20mSv. We compared the dose reduction potential of advanced iterative reconstruction, Iterative Model Reconstruction (IMR, Philips Healthcare, Cleveland, Ohio) to hybrid iterative reconstruction (iDose4) and filtered back projection (FBP). Dynamic CTP scans were obtained using a porcine model with balloon-induced ischemia in the left anterior descending coronary artery to prescribed fractional flow reserve values. High dose dynamic CTP scans were acquired at 100kVp/100mAs with effective dose of 23mSv. Low dose scans at 75mAs, 50mAs, and 25mAs were simulated by adding x-ray quantum noise and detector electronic noise to the projection space data. Images were reconstructed with FBP, iDose4, and IMR at each dose level. Image quality in static CTP images was assessed by SNR and CNR. Blood flow was obtained using a dynamic CTP analysis pipeline and blood flow image quality was assessed using flow-SNR and flow-CNR. IMR showed highest static image quality according to SNR and CNR. Blood flow in FBP was increasingly over-estimated at reduced dose. Flow was more consistent for iDose4 from 100mAs to 50mAs, but was over-estimated at 25mAs. IMR was most consistent from 100mAs to 25mAs. Static images and flow maps for 100mAs FBP, 50mAs iDose4, and 25mAs IMR showed comparable, clear ischemia, CNR, and flow-CNR values. These results suggest that IMR can enable dynamic CTP at significantly reduced dose, at 5.8mSv or 25% of the comparable 23mSv FBP protocol.
Collapse
Affiliation(s)
- Brendan L Eck
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Rachid Fahmi
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Christopher Fuqua
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Mani Vembar
- Philips Healthcare, Cleveland, OH 44143, USA
| | | | - Hiram G Bezerra
- Cardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Case Medical Center, Cleveland, OH, 44106, USA
| | - David L Wilson
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| |
Collapse
|
44
|
Noninvasive physiologic assessment of coronary stenoses using cardiac CT. BIOMED RESEARCH INTERNATIONAL 2015; 2015:435737. [PMID: 25685790 PMCID: PMC4320886 DOI: 10.1155/2015/435737] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2014] [Revised: 09/29/2014] [Accepted: 10/06/2014] [Indexed: 11/17/2022]
Abstract
Coronary CT angiography (CCTA) has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD). CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive "one-stop-shop" diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT), and transluminal attenuation gradient (TAG), CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.
Collapse
|
45
|
Myocardial blood flow quantification for evaluation of coronary artery disease by positron emission tomography, cardiac magnetic resonance imaging, and computed tomography. Curr Cardiol Rep 2014; 16:483. [PMID: 24718671 DOI: 10.1007/s11886-014-0483-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging, and computed tomography, and its emerging clinical applications.
Collapse
|
46
|
Noël PB, Köhler T, Fingerle AA, Brown KM, Zabic S, Münzel D, Haller B, Baum T, Henninger M, Meier R, Rummeny EJ, Dobritz M. Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography. J Med Imaging (Bellingham) 2014; 1:033501. [PMID: 26158054 DOI: 10.1117/1.jmi.1.3.033501] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 09/03/2014] [Accepted: 09/11/2014] [Indexed: 11/14/2022] Open
Abstract
The objective of this study was to investigate the improvement in diagnostic quality of an iterative model-based reconstruction (IMBR) algorithm for low-tube-voltage (80-kVp) and low-tube-current in abdominal computed tomography angiography (CTA). A total of 11 patients were imaged on a 256-slice multidetector computed tomography for visualization of the aorta. For all patients, three different reconstructions from the low-tube-voltage data are generated: filtered backprojection (FBP), IMBR, and a mixture of both [Formula: see text]. To determine the diagnostic value of IMBR-based reconstructions, the image quality was assessed. With IMBR-based reconstructions, image noise could be significantly reduced, which was confirmed by a highly improved contrast-to-noise ratio. In the image quality assessment, radiologists were able to reliably detect more third-order and higher aortic branches in the IMBR reconstructions compared to FBP reconstructions. The effective dose level was, on average, 3.0 mSv for 80-kVp acquisitions. Low-tube-voltage CTAs significantly improve vascular contrast as presented by others; however, this effect in combination with IMBR enabled yet another substantial improvement of diagnostic quality. For IMBR, a significant improvement of image quality and a decreased radiation dose at low-tube-voltage can be reported.
Collapse
Affiliation(s)
- Peter B Noël
- Technische Universität München , Department of Radiology, Munich 81675, Germany
| | - Thomas Köhler
- Philips Research Laboratories , Hamburg 22335, Germany
| | | | - Kevin M Brown
- Philips Healthcare , Cleveland, Ohio 44143, United States
| | | | - Daniela Münzel
- Technische Universität München , Department of Radiology, Munich 81675, Germany
| | - Bernhard Haller
- Technische Universität München , Institute of Medical Statistics and Epidemiology, Munich 81675, Germany
| | - Thomas Baum
- Technische Universität München , Department of Radiology, Munich 81675, Germany
| | - Martin Henninger
- Technische Universität München , Department of Radiology, Munich 81675, Germany
| | - Reinhard Meier
- Technische Universität München , Department of Radiology, Munich 81675, Germany
| | - Ernst J Rummeny
- Technische Universität München , Department of Radiology, Munich 81675, Germany
| | - Martin Dobritz
- Technische Universität München , Department of Radiology, Munich 81675, Germany
| |
Collapse
|
47
|
Muenzel D, Koehler T, Brown K, Žabić S, Fingerle AA, Waldt S, Bendik E, Zahel T, Schneider A, Dobritz M, Rummeny EJ, Noël PB. Validation of a low dose simulation technique for computed tomography images. PLoS One 2014; 9:e107843. [PMID: 25247422 PMCID: PMC4172631 DOI: 10.1371/journal.pone.0107843] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Accepted: 08/21/2014] [Indexed: 02/02/2023] Open
Abstract
PURPOSE Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. MATERIALS AND METHODS Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10-80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. RESULTS Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was -1.2% (range -9% to 3.2%) and -0.2% (range -8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9-10.2 HU (noise) and 1.9-13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. CONCLUSION Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques.
Collapse
Affiliation(s)
- Daniela Muenzel
- Department of Radiology, Technische Universitaet Muenchen, Munich, Germany
- * E-mail:
| | - Thomas Koehler
- Philips Technologie GmbH, Innovative Technologies, Hamburg, Germany
| | - Kevin Brown
- Philips Healthcare, Cleveland, Ohio, United States of America
| | - Stanislav Žabić
- Philips Healthcare, Cleveland, Ohio, United States of America
| | | | - Simone Waldt
- Department of Radiology, Technische Universitaet Muenchen, Munich, Germany
| | - Edgar Bendik
- Department of Radiology, Technische Universitaet Muenchen, Munich, Germany
| | - Tina Zahel
- Department of Radiology, Technische Universitaet Muenchen, Munich, Germany
| | - Armin Schneider
- MITI - Minimal-invasive Interdisciplinary therapeutic intervention research group, Technische Universitaet Muenchen, Munich, Germany
| | - Martin Dobritz
- Department of Radiology, Technische Universitaet Muenchen, Munich, Germany
| | - Ernst J. Rummeny
- Department of Radiology, Technische Universitaet Muenchen, Munich, Germany
| | - Peter B. Noël
- Department of Radiology, Technische Universitaet Muenchen, Munich, Germany
| |
Collapse
|
48
|
Kim SM, Cho YK, Choe YH. Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT in patients with normal body mass indices: effect of tube voltage, tube current, and iodine concentration on image quality and radiation dose. Int J Cardiovasc Imaging 2014; 30 Suppl 2:95-103. [PMID: 25156692 DOI: 10.1007/s10554-014-0524-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Accepted: 08/15/2014] [Indexed: 10/24/2022]
Abstract
The aim of this study was to evaluate the image quality and radiation dose in adenosine-stress dynamic myocardial CT perfusion (CTP) imaging using different tube voltages, tube current settings, and contrast materials containing different iodine concentrations in subjects with normal body mass indices (BMI). We included 92 patients (BMI range, 18.5-24.8) who underwent dynamic CTP for the evaluation of coronary artery disease using a 128-slice dual-source computed tomography. The protocols employed the following dynamic scan parameters: protocol I with 100 kV, fixed tube current (FTC), and medium-concentration contrast material (MC, 350 mg iodine/mL); protocol II with 100 kV, automatic tube current modulation (ATCM), and MC; protocol III with 100 kV, ATCM, and high-concentration contrast material (HC, 400 mg iodine/mL); protocol IV with 80 kV, adopted FTC, and HC. Subjective image quality on a 1-3 point scale and objective image quality with respect to the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed. Protocol IV showed higher CNR and SNR than the other protocols (P < 0.01), while the CNR and SNR values did not significantly differ among the other three protocols. There was no significant difference in subjective image quality among the protocols. The radiation dose in protocol IV was the lowest among the protocols (P < 0.01), while protocol IV resulted in a 54% overall reduction in mean effective radiation dose compared with protocol I. Dynamic myocardial CTP performed at 80 kV with adapted FTC provided high CNR and SNR while preserving subjective image quality and reducing radiation exposure.
Collapse
Affiliation(s)
- Sung Mok Kim
- Department of Radiology and Cardiovascular Imaging Center, Cardiac and Vascular Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 135-710, Korea
| | | | | |
Collapse
|
49
|
De Geer J, Gjerde M, Brudin L, Olsson E, Persson A, Engvall J. Large variation in blood flow between left ventricular segments, as detected by adenosine stress dynamic CT perfusion. Clin Physiol Funct Imaging 2014; 35:291-300. [DOI: 10.1111/cpf.12163] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2013] [Accepted: 04/16/2014] [Indexed: 12/01/2022]
Affiliation(s)
- Jakob De Geer
- Faculty of Health Sciences; Department of Medical and Health Sciences; Department of Radiology in Linköping; Center for Medical Image Science and Visualization (CMIV); Linköping University; County Council of Östergötland; Linköping Sweden
| | - Marcus Gjerde
- Faculty of Health Sciences; Department of Medical and Health Sciences; Department of Cardiology in Linköping; Center for Medical Image Science and Visualization (CMIV); Linköping University; County Council of Östergötland; Linköping Sweden
| | - Lars Brudin
- Faculty of Health Sciences; Department of Medical and Health Sciences; Department of Clinical Physiology in Kalmar; Linköping University; County Council of Kalmar; Kalmar Sweden
| | - Eva Olsson
- Faculty of Health Sciences; Department of Medical and Health Sciences; Department of Clinical Physiology; Center for Medical Image Science and Visualization (CMIV); Linköping University; County Council of Östergötland; Linköping Sweden
| | - Anders Persson
- Faculty of Health Sciences; Department of Medical and Health Sciences; Department of Radiology in Linköping; Center for Medical Image Science and Visualization (CMIV); Linköping University; County Council of Östergötland; Linköping Sweden
| | - Jan Engvall
- Faculty of Health Sciences; Department of Medical and Health Sciences; Department of Clinical Physiology; Center for Medical Image Science and Visualization (CMIV); Linköping University; County Council of Östergötland; Linköping Sweden
| |
Collapse
|
50
|
Hashemi S, Mehrez H, Cobbold RSC, Paul NS. Optimal image reconstruction for detection and characterization of small pulmonary nodules during low-dose CT. Eur Radiol 2014; 24:1239-50. [PMID: 24658869 DOI: 10.1007/s00330-014-3142-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2013] [Revised: 02/18/2014] [Accepted: 03/04/2014] [Indexed: 12/21/2022]
Affiliation(s)
- SayedMasoud Hashemi
- Institute of Biomaterial and Biomedical Engineering, University of Toronto, Room RS-420A, 164 College Street, Toronto, ON, Canada, M5S 3G9
| | | | | | | |
Collapse
|