Muh CR, Dorilio JR, Beaudreault CP, McGoldrick PE, Pisapia JM, Wolf SM. Feasibility and safety of stereoelectroencephalography in young children. Childs Nerv Syst 2024; 40:1331-1337. [PMID: 38451299 DOI: 10.1007/s00381-024-06335-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 02/23/2024] [Indexed: 03/08/2024]
Abstract
PURPOSE Stereoelectroencephalography (SEEG) is a diagnostic surgery that implants electrodes to identify areas of epileptic onset in patients with drug-resistant epilepsy (DRE). SEEG is effective in identifying the epileptic zone; however, placement of electrodes in very young children has been considered contraindicated due to skull thinness. The goal of this study was to evaluate if SEEG is safe and accurate in young children with thin skulls. METHODS Four children under the age of two years old with DRE underwent SEEG to locate the region of seizure onset. Presurgical planning and placement of electrodes were performed using ROSA One Brain. Preoperative electrode plans were merged with postoperative CT scans to determine accuracy. Euclidean distance between the planned and actual trajectories was calculated using a 3D coordinate system at both the entry and target points for each electrode. RESULTS Sixty-three electrodes were placed among four patients. Mean skull thickness at electrode entry sites was 2.34 mm. The mean difference between the planned and actual entry points was 1.12 mm, and the mean difference between the planned and actual target points was 1.73 mm. No significant correlation was observed between planned and actual target points and skull thickness (Pearson R = - 0.170). No perioperative or postoperative complications were observed. CONCLUSIONS This study demonstrates that SEEG can be safe and accurate in children under two years of age despite thin skulls. SEEG should be considered for young children with DRE, and age and skull thickness are not definite contraindications to the surgery.
Collapse
Affiliation(s)
- Carrie R Muh
- Department of Neurosurgery and Department of Pediatrics, Westchester Medical Center, 100 Woods Road, Taylor Pavilion E135, Valhalla, NY, 10595, USA.
- Department of Neurosurgery, New York Medical College, Valhalla, NY, 10595, USA.
| | | | | | - Patricia E McGoldrick
- Department of Pediatric Neurology, Boston Children's Health Physicians, Hawthorne, NY, USA
| | - Jared M Pisapia
- Department of Neurosurgery and Department of Pediatrics, Westchester Medical Center, 100 Woods Road, Taylor Pavilion E135, Valhalla, NY, 10595, USA
- Department of Neurosurgery, New York Medical College, Valhalla, NY, 10595, USA
| | - Steven M Wolf
- Department of Pediatric Neurology, Boston Children's Health Physicians, Hawthorne, NY, USA
- Department of Neurology, New York Medical College, Valhalla, NY, USA
| |
Collapse
|
2
|
Santos MV, Garcia CAB, Hamad APA, Costa UT, Sakamoto AC, Dos Santos AC, Machado HR. Clinical and Surgical Approach for Cerebral Cortical Dysplasia. Adv Tech Stand Neurosurg 2023; 48:327-354. [PMID: 37770690 DOI: 10.1007/978-3-031-36785-4_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/30/2023]
Abstract
The present article describes pathophysiological and clinical aspects of congenital malformations of the cerebral tissue (cortex and white matter) that cause epilepsy and very frequently require surgical treatment. A particular emphasis is given to focal cortical dysplasias, the most common pathology among these epilepsy-related malformations. Specific radiological and surgical features are also highlighted, so a thorough overview of cortical dysplasias is provided.
Collapse
Affiliation(s)
- Marcelo Volpon Santos
- Center for Pediatric Epilepsy Surgery (CIREP), Ribeirão Preto Medical School, University Hospital, University of São Paulo, São Paulo, SP, Brazil.
- Department of Surgery and Anantomy, Ribeirão Preto Medical School, University of São Paulo, São Paulo, SP, Brazil.
| | - Camila Araujo Bernardino Garcia
- Center for Pediatric Epilepsy Surgery (CIREP), Ribeirão Preto Medical School, University Hospital, University of São Paulo, São Paulo, SP, Brazil
| | - Ana Paula Andrade Hamad
- Center for Pediatric Epilepsy Surgery (CIREP), Ribeirão Preto Medical School, University Hospital, University of São Paulo, São Paulo, SP, Brazil
| | - Ursula Thome Costa
- Center for Pediatric Epilepsy Surgery (CIREP), Ribeirão Preto Medical School, University Hospital, University of São Paulo, São Paulo, SP, Brazil
| | - Americo Ceiki Sakamoto
- Center for Pediatric Epilepsy Surgery (CIREP), Ribeirão Preto Medical School, University Hospital, University of São Paulo, São Paulo, SP, Brazil
| | - Antonio Carlos Dos Santos
- Center for Pediatric Epilepsy Surgery (CIREP), Ribeirão Preto Medical School, University Hospital, University of São Paulo, São Paulo, SP, Brazil
| | - Helio Rubens Machado
- Center for Pediatric Epilepsy Surgery (CIREP), Ribeirão Preto Medical School, University Hospital, University of São Paulo, São Paulo, SP, Brazil
| |
Collapse
|
3
|
Boop S, Barkley A, Emerson S, Prolo LM, Goldstein H, Ojemann JG, Hauptman JS. Robot-assisted stereoelectroencephalography in young children: technical challenges and considerations. Childs Nerv Syst 2022; 38:263-267. [PMID: 34716458 DOI: 10.1007/s00381-021-05384-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 09/29/2021] [Indexed: 11/29/2022]
Abstract
Robot-assisted stereoelectroencephalography (sEEG) is frequently employed to localize epileptogenic zones in patients with medically refractory epilepsy (MRE). Its methodology is well described in adults, but less so in children. Given the limited information available on pediatric applications, the objective is to describe the unique technical challenges and considerations of sEEG in the pediatric population. In this report, we describe our institutional experience with the technical aspects of robot-assisted sEEG in an exclusively pediatric epilepsy surgery unit, focusing on pre-, intra-, and post-operative nuances that are particular to the pediatric population. The pediatric population presents several unique challenges in sEEG, including reduced skull thickness relative to adults, incomplete neurologic development, and often special behavioral considerations. Pre-operative selection of putative epileptogenic zones requires careful multidisciplinary decision-making. Intraoperative attention to nuances in positioning, clamp selection, registration, and electrode placement are necessary. Activity considerations and electrode migration and removal are key post-operative considerations. Robot-assisted sEEG is a valuable tool in the armamentarium of techniques to characterize MRE. However, special considerations must be given to the pediatric population to optimize safety and efficacy.
Collapse
Affiliation(s)
- Scott Boop
- Department of Neurological Surgery, University of Washington, Seattle, WA, USA
| | - Ariana Barkley
- Department of Neurological Surgery, University of Washington, Seattle, WA, USA
| | - Samuel Emerson
- Department of Neurological Surgery, University of Washington, Seattle, WA, USA
| | - Laura M Prolo
- Department of Neurosurgery, Stanford University, Stanford, CA, USA
| | - Hannah Goldstein
- Department of Neurosurgery, Seattle Children's Hospital, 4800 Sand Point Way NE, OA.9.220, Seattle, WA, 98105, USA
| | - Jeffrey G Ojemann
- Department of Neurological Surgery, University of Washington, Seattle, WA, USA.,Department of Neurosurgery, Seattle Children's Hospital, 4800 Sand Point Way NE, OA.9.220, Seattle, WA, 98105, USA
| | - Jason S Hauptman
- Department of Neurological Surgery, University of Washington, Seattle, WA, USA. .,Department of Neurosurgery, Seattle Children's Hospital, 4800 Sand Point Way NE, OA.9.220, Seattle, WA, 98105, USA.
| |
Collapse
|
4
|
Belohlavkova A, Jahodova A, Kudr M, Benova B, Ebel M, Liby P, Taborsky J, Jezdik P, Janca R, Kyncl M, Tichy M, Krsek P. May intraoperative detection of stereotactically inserted intracerebral electrodes increase precision of resective epilepsy surgery? Eur J Paediatr Neurol 2021; 35:49-55. [PMID: 34610561 DOI: 10.1016/j.ejpn.2021.09.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 06/13/2021] [Accepted: 09/24/2021] [Indexed: 10/20/2022]
Abstract
OBJECT Epilepsy surgery is an effective treatment for selected patients with focal intractable epilepsy. Complete removal of the epileptogenic zone significantly increases the chances for postoperative seizure-freedom. In complex surgical candidates, delineation of the epileptogenic zone requires a long-term invasive video/EEG from intracranial electrodes. It is especially challenging to achieve a complete resection in deep brain structures such as opercular-insular cortex. We report a novel approach utilizing intraoperative visual detection of stereotactically implanted depth electrodes to inform and guide the extent of surgical resection. METHODS We retrospectively reviewed data of pediatric patients operated in Motol Epilepsy Center between October 2010 and June 2020 who underwent resections guided by intraoperative visual detection of depth electrodes following SEEG. The outcome in terms of seizure- and AED-freedom was assessed individually in each patient. RESULTS Nineteen patients (age at surgery 2.9-18.6 years, median 13 years) were included in the study. The epileptogenic zone involved opercular-insular cortex in eighteen patients. The intraoperative detection of the electrodes was successful in seventeen patients and the surgery was regarded complete in sixteen. Thirteen patients were seizure-free at final follow-up including six drug-free cases. The successful intraoperative detection of the electrodes was associated with favorable outcome in terms of achieving complete resection and seizure-freedom in most cases. On the contrary, the patients in whom the procedure failed had poor postsurgical outcome. CONCLUSION The reported technique helps to achieve the complete resection in challenging patients with the epileptogenic zone in deep brain structures.
Collapse
Affiliation(s)
- Anezka Belohlavkova
- Department of Paediatric Neurology, Charles University, 2nd Faculty of Medicine and Motol University Hospital, Motol Epilepsy Centre, Full Member of the ERN EpiCARE, V Uvalu 84, 15006, Prague, Czech Republic
| | - Alena Jahodova
- Department of Paediatric Neurology, Charles University, 2nd Faculty of Medicine and Motol University Hospital, Motol Epilepsy Centre, Full Member of the ERN EpiCARE, V Uvalu 84, 15006, Prague, Czech Republic
| | - Martin Kudr
- Department of Paediatric Neurology, Charles University, 2nd Faculty of Medicine and Motol University Hospital, Motol Epilepsy Centre, Full Member of the ERN EpiCARE, V Uvalu 84, 15006, Prague, Czech Republic
| | - Barbora Benova
- Department of Paediatric Neurology, Charles University, 2nd Faculty of Medicine and Motol University Hospital, Motol Epilepsy Centre, Full Member of the ERN EpiCARE, V Uvalu 84, 15006, Prague, Czech Republic
| | - Matyas Ebel
- Department of Paediatric Neurology, Charles University, 2nd Faculty of Medicine and Motol University Hospital, Motol Epilepsy Centre, Full Member of the ERN EpiCARE, V Uvalu 84, 15006, Prague, Czech Republic
| | - Petr Liby
- Department of Neurosurgery, Charles University, 2nd Faculty of Medicine and Motol University Hospital, V Uvalu 84, 15006, Prague, Czech Republic
| | - Jakub Taborsky
- Department of Neurosurgery, Charles University, 2nd Faculty of Medicine and Motol University Hospital, V Uvalu 84, 15006, Prague, Czech Republic
| | - Petr Jezdik
- Faculty of Electrical Engineering, Department of Circuit Theory, Czech Technical University in Prague, Technicka 2, 166 27 Prague, Czech Republic
| | - Radek Janca
- Faculty of Electrical Engineering, Department of Circuit Theory, Czech Technical University in Prague, Technicka 2, 166 27 Prague, Czech Republic
| | - Martin Kyncl
- Department of Radiology, Charles University, 2nd Faculty of Medicine and Motol University Hospital, V Uvalu 84, 15006, Prague, Czech Republic
| | - Michal Tichy
- Department of Neurosurgery, Charles University, 2nd Faculty of Medicine and Motol University Hospital, V Uvalu 84, 15006, Prague, Czech Republic
| | - Pavel Krsek
- Department of Paediatric Neurology, Charles University, 2nd Faculty of Medicine and Motol University Hospital, Motol Epilepsy Centre, Full Member of the ERN EpiCARE, V Uvalu 84, 15006, Prague, Czech Republic.
| |
Collapse
|
5
|
Ball T, González-Martínez J, Zemmar A, Sweid A, Chandra S, VanSickle D, Neimat JS, Jabbour P, Wu C. Robotic Applications in Cranial Neurosurgery: Current and Future. Oper Neurosurg (Hagerstown) 2021; 21:371-379. [PMID: 34192764 DOI: 10.1093/ons/opab217] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 05/16/2021] [Indexed: 12/19/2022] Open
Abstract
Robotics applied to cranial surgery is a fast-moving and fascinating field, which is transforming the practice of neurosurgery. With exponential increases in computing power, improvements in connectivity, artificial intelligence, and enhanced precision of accessing target structures, robots are likely to be incorporated into more areas of neurosurgery in the future-making procedures safer and more efficient. Overall, improved efficiency can offset upfront costs and potentially prove cost-effective. In this narrative review, we aim to translate a broad clinical experience into practical information for the incorporation of robotics into neurosurgical practice. We begin with procedures where robotics take the role of a stereotactic frame and guide instruments along a linear trajectory. Next, we discuss robotics in endoscopic surgery, where the robot functions similar to a surgical assistant by holding the endoscope and providing retraction, supplemental lighting, and correlation of the surgical field with navigation. Then, we look at early experience with endovascular robots, where robots carry out tasks of the primary surgeon while the surgeon directs these movements remotely. We briefly discuss a novel microsurgical robot that can perform many of the critical operative steps (with potential for fine motor augmentation) remotely. Finally, we highlight 2 innovative technologies that allow instruments to take nonlinear, predetermined paths to an intracranial destination and allow magnetic control of instruments for real-time adjustment of trajectories. We believe that robots will play an increasingly important role in the future of neurosurgery and aim to cover some of the aspects that this field holds for neurosurgical innovation.
Collapse
Affiliation(s)
- Tyler Ball
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA
| | | | - Ajmal Zemmar
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA.,Department of Neurosurgery, People's Hospital of Zhengzhou University, Henan Provincial People's Hospital, Henan University People's Hospital, Henan University School of Medicine, Zhengzhou, China
| | - Ahmad Sweid
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Sarat Chandra
- Department of Neurosurgery, All India Institute of Medical Science, New Delhi, India
| | | | - Joseph S Neimat
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA
| | - Pascal Jabbour
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Chengyuan Wu
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
6
|
Bakr SM, Patel A, Zaazoue MA, Wagner K, Lam SK, Curry DJ, Raskin JS. Standard work tools for dynamic stereoelectroencephalography using ROSA: naming convention and perioperative planning. J Neurosurg Pediatr 2021; 27:411-419. [PMID: 33482632 DOI: 10.3171/2020.8.peds20420] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 08/11/2020] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The grid-based orthogonal placement of depth electrodes (DEs), initially defined by Jean Talairach and Jean Bancaud, is known as stereo-electroencephalography (sEEG). Although acceptance in the United States was initially slow, advances in imaging and technology have spawned a proliferation of North American epilepsy centers offering sEEG. Despite publications highlighting minimal access techniques and varied indications, standard work for phase I targeted DE has not been defined. In this article, the authors propose the term "dynamic sEEG" and define standard work tools and related common data elements to promote uniformity in the field. METHODS A multidisciplinary approach from July to August 2016 resulted in the production of 4 standard work tools for dynamic sEEG using ROSA: 1) a 34-page illustrated manual depicting a detailed workflow; 2) a planning form to collocate all the phase I data; 3) a naming convention for DEs that encodes the data defining it; and 4) a reusable portable perioperative planning and documentation board. A retrospective review of sEEG case efficiency was performed comparing those using standard work tools (between July 2016 and April 2017) with historical controls (between March 2015 and June 2016). The standard work tools were then instituted at another epilepsy surgery center, and the results were recorded. RESULTS The process for dynamic sEEG was formally reviewed, including anesthesia, positioning, perioperative nursing guidelines, surgical steps, and postoperative care for the workflow using cranial fixation and ROSA-guided placement. There was a 40% improvement in time per electrode, from 44.7 ± 9.0 minutes to 26.9 ± 6.5 minutes (p = 0.0007) following the development and use of the manual, the naming convention, and the reusable portable perioperative planning and documentation board. This standardized protocol was implemented at another institution and yielded a time per electrode of 22.3 ± 4.4 minutes. CONCLUSIONS The authors propose the term dynamic sEEG for stereotactic depth electrodes placed according to phase I workup data with the intention of converting to ablation. This workflow efficiency can be optimized using the standard work tools presented. The authors also propose a novel naming convention that encodes critical data and allows portability among providers. Use of a planning form for common data elements optimizes research, and global adoption could facilitate multicenter studies correlating phase I modality and seizure onset zone identification.
Collapse
Affiliation(s)
- Salma M Bakr
- 1Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, Indiana
- 2Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Ajay Patel
- 1Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - Mohamed A Zaazoue
- 1Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - Kathryn Wagner
- 3Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Sandi K Lam
- 4Division of Pediatric Neurosurgery, Ann and Robert H. Lurie Children's Hospital, Chicago; and
- 5Department of Neurosurgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Daniel J Curry
- 3Division of Pediatric Neurosurgery, Texas Children's Hospital, Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Jeffrey S Raskin
- 1Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| |
Collapse
|
7
|
Kim LH, Parker JJ, Ho AL, Pendharkar AV, Sussman ES, Halpern CH, Porter B, Grant GA. Postoperative outcomes following pediatric intracranial electrode monitoring: A case for stereoelectroencephalography (SEEG). Epilepsy Behav 2020; 104:106905. [PMID: 32028127 DOI: 10.1016/j.yebeh.2020.106905] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 12/15/2019] [Accepted: 01/06/2020] [Indexed: 01/29/2023]
Abstract
BACKGROUND For patients with medically refractory epilepsy, intracranial electrode monitoring can help identify epileptogenic foci. Despite the increasing utilization of stereoelectroencephalography (SEEG), the relative risks or benefits associated with the technique when compared with the traditional subdural electrode monitoring (SDE) remain unclear, especially in the pediatric population. Our aim was to compare the outcomes of pediatric patients who received intracranial monitoring with SEEG or SDE (grids and strips). METHODS We retrospectively studied 38 consecutive pediatric intracranial electrode monitoring cases performed at our institution from 2014 to 2017. Medical/surgical history and operative/postoperative records were reviewed. We also compared direct inpatient hospital costs associated with the two procedures. RESULTS Stereoelectroencephalography and SDE cohorts both showed high likelihood of identifying epileptogenic zones (SEEG: 90.9%, SDE: 87.5%). Compared with SDE, SEEG patients had a significantly shorter operative time (118.7 versus 233.4 min, P < .001) and length of stay (6.2 versus 12.3 days, P < .001), including days spent in the intensive care unit (ICU; 1.4 versus 5.4 days, P < .001). Stereoelectroencephalography patients tended to report lower pain scores and used significantly less narcotic pain medications (54.2 versus 197.3 mg morphine equivalents, P = .005). No complications were observed. Stereoelectroencephalography and SDE cohorts had comparable inpatient hospital costs (P = .47). CONCLUSION In comparison with subdural electrode placement, SEEG results in a similarly favorable clinical outcome, but with reduced operative time, decreased narcotic usage, and superior pain control without requiring significantly higher costs. The potential for an improved postoperative intracranial electrode monitoring experience makes SEEG especially suitable for pediatric patients.
Collapse
Affiliation(s)
- Lily H Kim
- Department of Neurosurgery, Stanford University School of Medicine, United States of America
| | - Jonathon J Parker
- Department of Neurosurgery, Stanford University School of Medicine, United States of America
| | - Allen L Ho
- Department of Neurosurgery, Stanford University School of Medicine, United States of America
| | - Arjun V Pendharkar
- Department of Neurosurgery, Stanford University School of Medicine, United States of America
| | - Eric S Sussman
- Department of Neurosurgery, Stanford University School of Medicine, United States of America
| | - Casey H Halpern
- Department of Neurosurgery, Stanford University School of Medicine, United States of America
| | - Brenda Porter
- Department of Neurology, Stanford University School of Medicine, United States of America; Division of Pediatric Neurology, Lucile Packard Children's Hospital Stanford, United States of America
| | - Gerald A Grant
- Department of Neurosurgery, Stanford University School of Medicine, United States of America; Division of Pediatric Neurosurgery, Lucile Packard Children's Hospital Stanford, United States of America.
| |
Collapse
|
8
|
Feng AY, Ho AL, Kim LH, Sussman ES, Pendharkar AV, Iv M, Yeom KW, Halpern CH, Grant GA. Utilization of Novel High-Resolution, MRI-Based Vascular Imaging Modality for Preoperative Stereoelectroencephalography Planning in Children: A Technical Note. Stereotact Funct Neurosurg 2020; 98:1-7. [PMID: 32062664 DOI: 10.1159/000503693] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Accepted: 09/25/2019] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Stereoelectroencephalography (SEEG) is a powerful intracranial diagnostic tool that requires accurate imaging for proper electrode trajectory planning to ensure efficacy and maximize patient safety. Computed tomography (CT) angiography and digital subtraction angiography are commonly used, but recent developments in magnetic resonance angiography allow for high-resolution vascular visualization without added risks of radiation. We report on the accuracy of electrode placement under robotic assistance planning utilizing a novel high-resolution magnetic resonance imaging (MRI)-based imaging modality. METHODS Sixteen pediatric patients between February 2014 and October 2017 underwent SEEG exploration for epileptogenic zone localization. A gadolinium-enhanced 3D T1-weighted spoiled gradient recalled echo sequence with minimum echo time and repetition time was applied for background parenchymal suppression and vascular enhancement. Electrode placement accuracy was determined by analyzing postoperative CT scans laid over preoperative virtual electrode trajectory paths. Entry point, target point, and closest vessel intersection were measured. RESULTS For any intersection along the trajectory path, 57 intersected vessels were measured. The mean diameter of an intersected vessel was 1.0343 ± 0.1721 mm, and 21.05% of intersections involved superficial vessels. There were 157 overall intersection + near-miss events. The mean diameter for an involved vessel was 1.0236 ± 0.0928 mm, and superficial vessels were involved in 20.13%. Looking only at final electrode target, 3 intersection events were observed. The mean diameter of an intersected vessel was 1.0125 ± 0.2227 mm. For intersection + near-miss events, 24 were measured. An involved vessel's mean diameter was 1.1028 ± 0.2634 mm. For non-entry point intersections, 45 intersected vessels were measured. The mean diameter for intersected vessels was 0.9526 ± 0.0689 mm. For non-entry point intersections + near misses, 126 events were observed. The mean diameter for involved vessels was 0.9826 ± 0.1008 mm. CONCLUSION We believe this novel sequence allows better identification of superficial and deeper subcortical vessels compared to conventional T1-weighted gadolinium-enhanced MRI.
Collapse
Affiliation(s)
- Austin Y Feng
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - Allen L Ho
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - Lily H Kim
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - Eric S Sussman
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - Arjun V Pendharkar
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - Michael Iv
- Department of Radiology, Stanford University Medical Center, Stanford, California, USA
| | - Kristen W Yeom
- Department of Radiology, Pediatric Radiology, Lucile Packard Children's Hospital at Stanford, Stanford, California, USA
| | - Casey H Halpern
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - Gerald A Grant
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA, .,Division of Pediatric Neurosurgery, Lucile Packard Children's Hospital Stanford, Stanford, California, USA,
| |
Collapse
|
9
|
Gonzalez-Martinez J. Epilepsy: Invasive Monitoring. Stereotact Funct Neurosurg 2020. [DOI: 10.1007/978-3-030-34906-6_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
10
|
Ross L, Naduvil AM, Bulacio JC, Najm IM, Gonzalez-Martinez JA. Stereoelectroencephalography-Guided Laser Ablations in Patients With Neocortical Pharmacoresistant Focal Epilepsy: Concept and Operative Technique. Oper Neurosurg (Hagerstown) 2019; 15:656-663. [PMID: 29554343 DOI: 10.1093/ons/opy022] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2017] [Accepted: 01/23/2018] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Laser ablation surgery has had encouraging results in the treatment of multiple intracranial diseases including primary and metastatic brain tumors, radiation necrosis, and epilepsy. The use of the stereoelectroencephalography (SEEG) method in combination with laser thermocoagulation therapy with the goal of modulating epileptic networks in patients with neocortical nonlesional phamacoresistant epilepsy has not been previously described. OBJECTIVE To describe the novel methodological and conceptual aspects related to SEEG-guided laser ablations in patients with magnetic resonance imaging (MRI)-negative pharmacoresistant neocortical focal epilepsy. METHODS Guided by previous SEEG intracranial data, a laser ablation probe was inserted by using a robotic guidance device in a 17-yr-old medically refractory epilepsy patient with difficult to localize seizures and nonlesional MRI. The laser applicator position was confirmed by MRI, targeting the left mesial rostral superior frontal gyrus. The ablation was performed under multiplanar digital imaging views and real-time thermal imaging and treatment estimates in each plane. A postablation MRI (contrasted T1 sequence) confirmed the ablation's location and size. RESULTS The entire procedure was achieved in approximately 100 min. The actual ablation was performed in less than 3 min. Approximately, additional 30 min preoperatively were used for positioning and robot registration. Precise placement of laser application (in comparison with preplanned trajectories) was achieved using the robotic guidance and confirmed by the intraoperative magnetic resonance images. No complications were reported. The patient has been seizure-free since surgery. The follow-up period is 20 mo. Two additional patients, treated with similar methodology, are also described. CONCLUSION The preliminary experience with the described method shows the feasibility of a unique combination of the SEEG methodology with laser thermocoagulation in patients with neocortical MRI-negative pharmacoresistant focal epilepsy.
Collapse
Affiliation(s)
- Louis Ross
- Department of Neurosurgery, Cleveland Clinic, Ohio
| | | | | | - Imad M Najm
- Epilepsy Center, Cleveland Clinic, Cleveland, Ohio
| | - Jorge A Gonzalez-Martinez
- Department of Neurosurgery, Cleveland Clinic, Ohio.,Epilepsy Center, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
11
|
Tomlinson SB, Buch VP, Armstrong D, Kennedy BC. Stereoelectroencephalography in Pediatric Epilepsy Surgery. J Korean Neurosurg Soc 2019; 62:302-312. [PMID: 31085956 PMCID: PMC6514312 DOI: 10.3340/jkns.2019.0015] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 02/05/2019] [Indexed: 12/25/2022] Open
Abstract
Stereoelectroencephalography (SEEG) is an invasive technique used during the surgical management of medically refractory epilepsy. The utility of SEEG rests in its ability to survey the three-dimensional organization of the epileptogenic zone as well as nearby eloquent cortices. Once concentrated to specialized centers in Europe and Canada, the SEEG methodology has gained worldwide popularity due to its favorable morbidity profile, superior coverage of deep structures, and ability to perform multilobar explorations without the need for craniotomy. This rapid shift in practice represents both a challenge and an opportunity for pediatric neurosurgeons familiar with the subdural grid approach. The purpose of this review is to discuss the indications, technique, and safety of long-term SEEG monitoring in children. In addition to reviewing the conceptual and technical points of the diagnostic evaluation, attention will also be given to SEEG-based interventions (e.g., radiofrequency thermo-coagulation).
Collapse
Affiliation(s)
- Samuel B Tomlinson
- Division of Neurosurgery, Children's Hospital of Philadelphia, Philadelphia, PA, USA.,School of Medicine and Dentistry, University of Rochester Medical Center, Rochester, NY, USA
| | - Vivek P Buch
- Department of Neurosurgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Dallas Armstrong
- Division of Child Neurology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Benjamin C Kennedy
- Division of Neurosurgery, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| |
Collapse
|
12
|
Youngerman BE, Khan FA, McKhann GM. Stereoelectroencephalography in epilepsy, cognitive neurophysiology, and psychiatric disease: safety, efficacy, and place in therapy. Neuropsychiatr Dis Treat 2019; 15:1701-1716. [PMID: 31303757 PMCID: PMC6610288 DOI: 10.2147/ndt.s177804] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Accepted: 05/22/2019] [Indexed: 12/14/2022] Open
Abstract
For patients with drug-resistant epilepsy, surgical intervention may be an effective treatment option if the epileptogenic zone (EZ) can be well localized. Subdural strip and grid electrode (SDE) implantations have long been used as the mainstay of intracranial seizure localization in the United States. Stereoelectroencephalography (SEEG) is an alternative approach in which depth electrodes are placed through percutaneous drill holes to stereotactically defined coordinates in the brain. Long used in certain centers in Europe, SEEG is gaining wider popularity in North America, bolstered by the advent of stereotactic robotic assistance and mounting evidence of safety, without the need for catheter-based angiography. Rates of clinically significant hemorrhage, infection, and other complications appear lower with SEEG than with SDE implants. SEEG also avoids unnecessary craniotomies when seizures are localized to unresectable eloquent cortex, found to be multifocal or nonfocal, or ultimately treated with stereotactic procedures such as laser interstitial thermal therapy (LITT), radiofrequency thermocoagulation (RF-TC), responsive neurostimulation (RNS), or deep brain stimulation (DBS). While SDE allows for excellent localization and functional mapping on the cortical surface, SEEG offers a less invasive option for sampling disparate brain areas, bilateral investigations, and deep or medial targets. SEEG has shown efficacy for seizure localization in the temporal lobe, the insula, lesional and nonlesional extra-temporal epilepsy, hypothalamic hamartomas, periventricular nodular heterotopias, and patients who have had prior craniotomies for resections or grids. SEEG offers a valuable opportunity for cognitive neurophysiology research and may have an important role in the study of dysfunctional networks in psychiatric disease and understanding the effects of neuromodulation.
Collapse
Affiliation(s)
- Brett E Youngerman
- Department of Neurological Surgery, Columbia University Medical Center, New York, NY, USA
| | - Farhan A Khan
- Department of Neurological Surgery, Columbia University Medical Center, New York, NY, USA
| | - Guy M McKhann
- Department of Neurological Surgery, Columbia University Medical Center, New York, NY, USA
| |
Collapse
|
13
|
Scavarda D, Cavalcante T, Trébuchon A, Lépine A, Villeneuve N, Girard N, McGonigal A, Milh M, Bartolomei F. Tailored suprainsular partial hemispherotomy: a new functional disconnection technique for stroke-induced refractory epilepsy. J Neurosurg Pediatr 2018; 22:601-609. [PMID: 30141751 DOI: 10.3171/2018.5.peds17709] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Accepted: 05/22/2018] [Indexed: 01/05/2023]
Abstract
OBJECTIVEHemispherotomy is currently the most frequently performed surgical option for refractory epilepsy associated with large perinatal or childhood ischemic events. Such an approach may lead to good seizure control, but it has inherent functional consequences linked to the disconnection of functional cortices. The authors report on 6 consecutive patients who presented with severe epilepsy associated with hemiplegia due to stroke and who benefitted from a new, stereoelectroencephalography-guided partial disconnection technique.METHODSThe authors developed a new disconnection technique termed "tailored suprainsular partial hemispherotomy" (TSIPH). Disconnection always included premotor and motor cortex with variable anterior and posterior extent.RESULTSAt a mean follow-up of 28 months, there were no deaths and no patient had hydrocephalus. Motor degradation was observed in all patients in the 2 weeks after surgery, but all patients completely recovered. The 6 patients were seizure free (Engel class IA) at the last follow-up. No neuropsychological aggravation was observed.CONCLUSIONSTSIPH appears to be a conservative alternative to classic hemispherotomy, leading to favorable outcome in this series.
Collapse
Affiliation(s)
| | | | - Agnès Trébuchon
- 2Institut de Neurosciences des Systèmes, Aix Marseille Université; and
- 3Neurophysiologie Clinique
| | - Anne Lépine
- 4Neurologie Pédiatrique, and
- 5Hôpital Henri Gastaut, Marseille, France
| | | | | | - Aileen McGonigal
- 2Institut de Neurosciences des Systèmes, Aix Marseille Université; and
- 3Neurophysiologie Clinique
| | | | - Fabrice Bartolomei
- 2Institut de Neurosciences des Systèmes, Aix Marseille Université; and
- 3Neurophysiologie Clinique
| |
Collapse
|
14
|
Ho AL, Feng AY, Kim LH, Pendharkar AV, Sussman ES, Halpern CH, Grant GA. Stereoelectroencephalography in children: a review. Neurosurg Focus 2018; 45:E7. [DOI: 10.3171/2018.6.focus18226] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Stereoelectroencephalography (SEEG) is an intracranial diagnostic measure that has grown in popularity in the United States as outcomes data have demonstrated its benefits and safety. The main uses of SEEG include 1) exploration of deep cortical/sulcal structures; 2) bilateral recordings; and 3) 3D mapping of epileptogenic zones. While SEEG has gradually been accepted for treatment in adults, there is less consensus on its utility in children. In this literature review, the authors seek to describe the current state of SEEG with a focus on the more recent technology-enabled surgical techniques and demonstrate its efficacy in the pediatric epilepsy population.
Collapse
Affiliation(s)
- Allen L. Ho
- 1Department of Neurosurgery, Stanford University School of Medicine; and
| | - Austin Y. Feng
- 1Department of Neurosurgery, Stanford University School of Medicine; and
| | - Lily H. Kim
- 1Department of Neurosurgery, Stanford University School of Medicine; and
| | | | - Eric S. Sussman
- 1Department of Neurosurgery, Stanford University School of Medicine; and
| | - Casey H. Halpern
- 1Department of Neurosurgery, Stanford University School of Medicine; and
| | - Gerald A. Grant
- 1Department of Neurosurgery, Stanford University School of Medicine; and
- 2Division of Pediatric Neurosurgery, Lucile Packard Children’s Hospital, Stanford, California
| |
Collapse
|
15
|
Gunnarsdottir KM, Li A, Bulacio J, Gonzalez-Martinez J, Sarma SV. Estimating unmeasured invasive EEG signals using a reduced-order observer. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2017:3216-3219. [PMID: 29060582 DOI: 10.1109/embc.2017.8037541] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Epilepsy affects around 50 million people worldwide. Over 30% of patients are drug-resistant where the only treatment may be surgical resection of the epileptogenic zone (EZ), the region of the brain that generates seizures. Identification of the EZ is often based on invasive EEG recordings. As such, surgical outcome relies heavily on precise and dense placement of EEG electrodes into the brain. Despite large brain regions being removed, success rates barely reach 65%. This gives rise to the "missing electrode problem", where clinicians want to know what neural activity looks like between sparsely implanted electrodes. Solving this problem will enable more accurate localization of the EZ. In this paper, we demonstrate the first steps towards developing a computational platform to estimate neural activity at the "missing electrodes" using a reduced-order observer from control theory. Specifically, we constructed a sequence of discrete time Linear Time-Invariant (LTI) models using the available EEG data from two epilepsy patients. Then, we used the models to simulate EEG data and remove selected signals ("missing" states) from the simulated data set. Finally, we used a reduced-order observer to estimate the signals of these "missing" states and evaluated performance by comparing the observer estimates to the simulated EEG time series.
Collapse
|
16
|
|
17
|
Radhakrishnan A, Menon R, Abraham M, Vilanilam G, Sharma S, Thomas B, Kesavadas C, Cherian A, Varma R, Thomas SV. Predictors of outcome after surgery in 134 children with drug-resistant TLE. Epilepsy Res 2018; 139:150-156. [DOI: 10.1016/j.eplepsyres.2017.11.020] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2017] [Revised: 11/23/2017] [Accepted: 11/29/2017] [Indexed: 12/01/2022]
|
18
|
Alomar S, Mullin JP, Smithason S, Gonzalez-Martinez J. Indications, technique, and safety profile of insular stereoelectroencephalography electrode implantation in medically intractable epilepsy. J Neurosurg 2017. [PMID: 28621621 DOI: 10.3171/2017.1.jns161070] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Insular epilepsy is relatively rare; however, exploring the insular cortex when preoperative workup raises the suspicion of insular epilepsy is of paramount importance for accurate localization of the epileptogenic zone and achievement of seizure freedom. The authors review their clinical experience with stereoelectroencephalography (SEEG) electrode implantation in patients with medically intractable epilepsy and suspected insular involvement. METHODS A total of 198 consecutive cases in which patients underwent SEEG implantation with a total of 1556 electrodes between June 2009 and April 2013 were reviewed. The authors identified patients with suspected insular involvement based on seizure semiology, scalp EEG data, and preoperative imaging (MRI, PET, and SPECT or magnetoencephalography [MEG]). Patients with at least 1 insular electrode based on the postoperative 3D reconstruction of CT fused with the preoperative MRI were included. RESULTS One hundred thirty-five patients with suspected insular epilepsy underwent insular implantation of a total of 303 electrodes (1-6 insular electrodes per patient) with a total of 562 contacts. Two hundred sixty-eight electrodes (88.5%) were implanted orthogonally through the frontoparietal or temporal operculum (420 contacts). Thirty-five electrodes (11.5%) were implanted by means of an oblique trajectory either through a frontal or a parietal entry point (142 contacts). Nineteen patients (14.07%) had insular electrodes placed bilaterally. Twenty-three patients (17.04% of the insular implantation group and 11.6% of the whole SEEG cohort) were confirmed by SEEG to have ictal onset zones in the insula. None of the patients experienced any intracerebral hemorrhage related to the insular electrodes. After insular resection, 5 patients (33.3%) had Engel Class I outcomes, 6 patients (40%) had Engel Class II, 3 patients (20%) had Engel Class III, and 1 patient (6.66%) had Engel Class IV. CONCLUSIONS Insula exploration with stereotactically placed depth electrodes is a safe technique. Orthogonal electrodes are implanted when the hypothesis suggests opercular involvement; however, oblique electrodes allow a higher insular sampling rate.
Collapse
Affiliation(s)
- Soha Alomar
- 1Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio; and.,2King Abdulaziz University Hospital, Jeddah, Saudi Arabia
| | - Jeffrey P Mullin
- 1Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio; and
| | - Saksith Smithason
- 1Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio; and
| | | |
Collapse
|
19
|
Hupalo M, Wojcik R, Jaskolski DJ. Intracranial video-EEG monitoring in presurgical evaluation of patients with refractory epilepsy. Neurol Neurochir Pol 2017; 51:201-207. [PMID: 28279512 DOI: 10.1016/j.pjnns.2017.02.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Accepted: 02/09/2017] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Reviewing our experience in intracranial video-EEG monitoring in the presurgical evaluation of patients with refractory epilepsy. METHODS We report on 62 out of 202 (31%) patients with refractory epilepsy, who underwent a long term video-EEG monitoring (LTM). The epileptogenic zone (EZ) was localised either based on the results of LTM or after intracranial EEG recordings from depth, subdural or foramen ovale electrodes. The decision on the location of the electrodes was based upon semiology of the seizures, EEG findings and the lesions visualised in MRI brain scan. Intraoperative corticography was carried out before and right after the resection of the seizure onset zone. RESULTS The video-EEG monitoring could localise EZ in 43 (69%) cases based. The remaining patients underwent invasive diagnostics: 10 (53%) had intracerebral depth electrodes, 6 (31%) depth and subdural and 3 (16%) foramen ovale electrodes. Intracranial video EEG recordings showed seizure focus in all the patients. Ten of them had EZ in mesial temporal structures, 4 in accessory motor area, 3 at the base of the frontal lobe and 2 in parietal lobe. There was one case of an asymptomatic intracerebral haematoma at the electrode. All patients were subsequently operated on. In 15 (79%) cases the seizures subsided (follow-up from 2 to 5 years), in 4 (21%) they decreased. CONCLUSIONS The intracranial EEG is required in all patients with normal MRI (so-called nonlesional cases) in whom EZ is suspected to be located in the hippocampus, insula or in the basal parts of the frontal lobe.
Collapse
Affiliation(s)
- Marlena Hupalo
- Department of Neurosurgery and Oncology of Central Nervous System, Barlicki University Hospital, Medical University of Lodz, Lodz, Poland
| | - Rafal Wojcik
- Department of Neurosurgery and Oncology of Central Nervous System, Barlicki University Hospital, Medical University of Lodz, Lodz, Poland
| | - Dariusz J Jaskolski
- Department of Neurosurgery and Oncology of Central Nervous System, Barlicki University Hospital, Medical University of Lodz, Lodz, Poland.
| |
Collapse
|
20
|
Park JT, Baca Vaca GF, Avery J, Miller JP. Utility of Stereoelectroencephalography in Children with Dysembryoplastic Neuroepithelial Tumor and Cortical Malformation. Neurodiagn J 2017; 57:191-210. [PMID: 28898173 DOI: 10.1080/21646821.2017.1326270] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
BACKGROUND Uncontrolled seizures in children can contribute to irreversible cognitive impairment and developmental delay, in addition to placing them at risk for sudden unexplained death in epileptic patients (SUDEP). Since its introduction at Saint Ann Hospital in Paris in the 1960s, stereoelectroencephalography (SEEG) is increasingly being utilized at epilepsy centers in the United States as an invasive tool to help localize the seizure focus in drug-resistant focal epilepsy. INDICATIONS Children with symptomatic epilepsy, commonly due to cortical dysplasia and dysembryoplastic neuroepithelial tumor (DNET), may benefit from SEEG investigation. The arrangement of SEEG electrodes is individually tailored based on the suspected location of the epileptogenic zone (EZ). The implanted depth electrodes are used to electrically stimulate the corresponding cortices to obtain information about the topography of eloquent cortex and EZ. Morbidity: Surgical morbidity in these children undergoing SEEG investigation is low, but not negligible. The number of electrodes directly correlates with the risk of intraoperative complication. Thus a risk and benefit analysis needs to be carefully considered for each patient. Neurodiagnostic technology: Both during and after the SEEG electrode implantation, the intraoperative monitoring and EEG technologists play a vital role in the successful monitoring of the patient. CONCLUSION SEEG is an important tool in the process of epilepsy surgery in children with symptomatic epilepsy, commonly due to cortical dysplasia and DNET.
Collapse
Affiliation(s)
- Jun T Park
- a Epilepsy Center , Cleveland University Hospitals , Cleveland , Ohio
- b Case Western Reserve University School of Medicine , Cleveland , Ohio
| | - Guadalupe Fernandez Baca Vaca
- a Epilepsy Center , Cleveland University Hospitals , Cleveland , Ohio
- b Case Western Reserve University School of Medicine , Cleveland , Ohio
| | - Jennifer Avery
- a Epilepsy Center , Cleveland University Hospitals , Cleveland , Ohio
| | - Jonathan P Miller
- a Epilepsy Center , Cleveland University Hospitals , Cleveland , Ohio
- b Case Western Reserve University School of Medicine , Cleveland , Ohio
| |
Collapse
|
21
|
Alomar S, Jones J, Maldonado A, Gonzalez-Martinez J. The Stereo-Electroencephalography Methodology. Neurosurg Clin N Am 2016; 27:83-95. [PMID: 26615111 DOI: 10.1016/j.nec.2015.08.003] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
The stereo-electroencephalography (SEEG) methodology and technique was developed almost 60 years ago in Europe. The efficacy and safety of SEEG has been proven. The main advantage is the possibility to study the epileptogenic neuronal network in its dynamic and 3-dimensional aspect, with optimal time and space correlation, with the clinical semiology of the patient's seizures. The main clinical challenge for the near future remains in the further refinement of specific selection criteria for the different methods of invasive monitoring, with the ultimate goal of comparing and validating the results (long-term seizure-free outcome) obtained from different methods of invasive monitoring.
Collapse
Affiliation(s)
- Soha Alomar
- Department of Neurosurgery, Epilepsy Center, Neurological Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Jaes Jones
- Department of Neurosurgery, Epilepsy Center, Neurological Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Andres Maldonado
- Department of Neurosurgery, Epilepsy Center, Neurological Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Jorge Gonzalez-Martinez
- Department of Neurosurgery, Epilepsy Center, Neurological Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA.
| |
Collapse
|
22
|
Lesional cerebellar epilepsy: a review of the evidence. J Neurol 2016; 264:1-10. [PMID: 27260293 DOI: 10.1007/s00415-016-8161-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2016] [Revised: 05/03/2016] [Accepted: 05/04/2016] [Indexed: 10/21/2022]
Abstract
Classical teaching in epileptology localizes the origins of focal seizures solely in the cerebral cortex, with only inhibitory effects attributed to subcortical structures. However, electrophysiological and neuroimaging studies over the last decades now provide evidence for an initiation of epileptic seizures within subcortical structures. Intrinsic epileptogenicity of hypothalamic hamartoma has already been established in recognition of subcortical epilepsy, whereas a seizure-generating impact of dysplastic cerebellar lesions remains to be clarified. Herein, we examine the supportive evidence and clinical presentation of cerebellar seizures and review therapy options.
Collapse
|
23
|
Stereo-Encephalography Versus Subdural Electrodes for Seizure Localization. Neurosurg Clin N Am 2016; 27:97-109. [DOI: 10.1016/j.nec.2015.08.008] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
24
|
González-Martínez J, Bulacio J, Thompson S, Gale J, Smithason S, Najm I, Bingaman W. Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography. Neurosurgery 2015; 78:169-80. [DOI: 10.1227/neu.0000000000001034] [Citation(s) in RCA: 209] [Impact Index Per Article: 20.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
ABSTRACT
BACKGROUND:
Robot-assisted stereoelectroencephalography (SEEG) may represent a simplified, precise, and safe alternative to the more traditional SEEG techniques.
OBJECTIVE:
To report our clinical experience with robotic SEEG implantation and to define its utility in the management of patients with medically refractory epilepsy.
METHODS:
The prospective observational analyses included all patients with medically refractory focal epilepsy who underwent robot-assisted stereotactic placement of depth electrodes for extraoperative brain monitoring between November 2009 and May 2013. Technical nuances of the robotic implantation technique are presented, as well as an analysis of demographics, time of planning and procedure, seizure outcome, in vivo accuracy, and procedure-related complications.
RESULTS:
One hundred patients underwent 101 robot-assisted SEEG procedures. Their mean age was 33.2 years. In total, 1245 depth electrodes were implanted. On average, 12.5 electrodes were implanted per patient. The time of implantation planning was 30 minutes on average (range, 15-60 minutes). The average operative time was 130 minutes (range, 45-160 minutes). In vivo accuracy (calculated in 500 trajectories) demonstrated a median entry point error of 1.2 mm (interquartile range, 0.78-1.83 mm) and a median target point error of 1.7 mm (interquartile range, 1.20-2.30 mm). Of the group of patients who underwent resective surgery (68 patients), 45 (66.2%) gained seizure freedom status. Mean follow-up was 18 months. The total complication rate was 4%.
CONCLUSION:
The robotic SEEG technique and method were demonstrated to be safe, accurate, and efficient in anatomically defining the epileptogenic zone and subsequently promoting sustained seizure freedom status in patients with difficult-to-localize seizures.
Collapse
Affiliation(s)
- Jorge González-Martínez
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - Juan Bulacio
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - Susan Thompson
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - John Gale
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - Saksith Smithason
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - Imad Najm
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - William Bingaman
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
25
|
|
26
|
Abstract
Medically refractory epilepsy is a significant cause of morbidity and mortality in pediatric neurology. Surgical intervention has been well established as a viable treatment option in certain cases. This article reviews the process of selecting appropriate patients using the latest advances in neuroimaging and electrophysiologic techniques. It also discusses the various surgical techniques currently available, including recent advances in minimally invasive approaches.
Collapse
|