1
|
Ahmed AMM, Buschmann M, Breyer L, Kuntner C, Homolka P. Tailoring the Mass Density of 3D Printing Materials for Accurate X-ray Imaging Simulation by Controlled Underfilling for Radiographic Phantoms. Polymers (Basel) 2024; 16:1116. [PMID: 38675035 PMCID: PMC11053449 DOI: 10.3390/polym16081116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 03/26/2024] [Accepted: 04/11/2024] [Indexed: 04/28/2024] Open
Abstract
Additive manufacturing and 3D printing allow for the design and rapid production of radiographic phantoms for X-ray imaging, including CT. These are used for numerous purposes, such as patient simulation, optimization of imaging procedures and dose levels, system evaluation and quality assurance. However, standard 3D printing polymers do not mimic X-ray attenuation properties of tissues like soft, adipose, lung or bone tissue, and standard materials like liquid water. The mass density of printing polymers-especially important in CT-is often inappropriate, i.e., mostly too high. Different methods can be applied to reduce mass density. This work examines reducing density by controlled underfilling either realized by using 3D printing materials expanded through foaming during heating in the printing process, or reducing polymer flow to introduce microscopic air-filled voids. The achievable density reduction depends on the base polymer used. When using foaming materials, density is controlled by the extrusion temperature, and ranges from 33 to 47% of the base polymer used, corresponding to a range of -650 to -394 HU in CT with 120 kV. Standard filaments (Nylon, modified PLA and modified ABS) allowed density reductions by 20 to 25%, covering HU values in CT from -260 to 77 (Nylon), -230 to -20 (ABS) and -81 to 143 (PLA). A standard chalk-filled PLA filament allowed reproduction of bone tissue in a wide range of bone mineral content resulting in CT numbers from 57 to 460 HU. Controlled underfilling allowed the production of radiographic phantom materials with continuously adjustable attenuation in a limited but appropriate range, allowing for the reproduction of X-ray attenuation properties of water, adipose, soft, lung, and bone tissue in an accurate, predictable and reproducible manner.
Collapse
Affiliation(s)
| | - Martin Buschmann
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, and University Hospital Vienna, 1090 Vienna, Austria;
| | - Lara Breyer
- Department of Biomedical Imaging and Image-Guided Therapy, Medical Imaging Cluster (MIC), Medical University of Vienna, 1090 Vienna, Austria; (L.B.); (C.K.)
| | - Claudia Kuntner
- Department of Biomedical Imaging and Image-Guided Therapy, Medical Imaging Cluster (MIC), Medical University of Vienna, 1090 Vienna, Austria; (L.B.); (C.K.)
| | - Peter Homolka
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
| |
Collapse
|
2
|
Ye Z, Qi M, Zhao Y, Wei W, Xu XG. ESTIMATION OF FETAL AND PEDIATRIC DOSES FROM CHEST CT EXAMINATIONS USING VIRTUALDOSE SOFTWARE. RADIATION PROTECTION DOSIMETRY 2023; 199:52-60. [PMID: 36373995 DOI: 10.1093/rpd/ncac225] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 09/28/2022] [Accepted: 10/15/2022] [Indexed: 06/16/2023]
Abstract
Pregnant women and children sometimes had to undergo chest computed tomography (CT) scans during the Corona Virus Disease 2019 (COVID-19) pandemic. This study estimated the fetal and pediatric doses from chest CT scans. Organ doses and effective doses were calculated using the VirtualDose-CT software. Two groups of computational human phantoms, pregnant females and pediatric patients were used in this study. The results of doses normalized to volumetric CT Dose Index (CTDIvol) can be used universally for other dosimetry studies. Based on our calculations and international survey data of CTDIvol, fetal absorbed doses from COVID-19-related chest CT were found to be 0.04-0.36, 0.05-0.44 and 0.07-0.61 mGy for 3, 6 and 9 months of pregnancy, respectively. When the scan range is extended to the abdominal region, fetal doses increase by almost 4-fold. Effective doses for COVID-19-related chest CT were 1.62-13.77, 1.58-13.46, 1.57-13.33 and 1.29-10.98 mSv for the newborn, 1-, 5- and 10-y-old children, respectively. In addition, the effects of specific axial scan ranges exceeding the thorax region were evaluated. Although doses from chest CT scans are small, such data allow radiologists and patients to be informed of the dose levels and ways to avoid unnecessary radiation.
Collapse
Affiliation(s)
- Zirui Ye
- School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026, China
- Institute of Nuclear Medical Physics, University of Science and Technology of China, Hefei 230026, China
| | - Miao Qi
- School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026, China
- Institute of Nuclear Medical Physics, University of Science and Technology of China, Hefei 230026, China
| | - Yingming Zhao
- Department of Radiology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230001, China
| | - Wei Wei
- Department of Radiology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230001, China
| | - X George Xu
- School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026, China
- Institute of Nuclear Medical Physics, University of Science and Technology of China, Hefei 230026, China
- Department of Radiation Oncology, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei 230001, China
| |
Collapse
|
3
|
Li WB, Bouvier-Capely C, Saldarriaga Vargas C, Andersson M, Madas B. Heterogeneity of dose distribution in normal tissues in case of radiopharmaceutical therapy with alpha-emitting radionuclides. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2022; 61:579-596. [PMID: 36239799 PMCID: PMC9630198 DOI: 10.1007/s00411-022-01000-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Accepted: 10/06/2022] [Indexed: 05/10/2023]
Abstract
Heterogeneity of dose distribution has been shown at different spatial scales in diagnostic nuclear medicine. In cancer treatment using new radiopharmaceuticals with alpha-particle emitters, it has shown an extensive degree of dose heterogeneity affecting both tumour control and toxicity of organs at risk. This review aims to provide an overview of generalized internal dosimetry in nuclear medicine and highlight the need of consideration of the dose heterogeneity within organs at risk. The current methods used for patient dosimetry in radiopharmaceutical therapy are summarized. Bio-distribution and dose heterogeneities of alpha-particle emitting pharmaceutical 223Ra (Xofigo) within bone tissues are presented as an example. In line with the strategical research agendas of the Multidisciplinary European Low Dose Initiative (MELODI) and the European Radiation Dosimetry Group (EURADOS), future research direction of pharmacokinetic modelling and dosimetry in patient radiopharmaceutical therapy are recommended.
Collapse
Affiliation(s)
- Wei Bo Li
- Helmholtz Zentrum München-German Research Center for Environmental Health (GmbH), Institute of Radiation Medicine, Neuherberg, Germany.
| | - Céline Bouvier-Capely
- Institut de Radioprotection et Sûreté Nucléaire (IRSN), PSE-SANTE/SESANE/LRSI, Fontenay-aux-Roses, France
| | - Clarita Saldarriaga Vargas
- Radiation Protection Dosimetry and Calibrations, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
- In Vivo Cellular and Molecular Imaging Laboratory, Vrije Universiteit Brussel, Brussels, Belgium
| | - Michelle Andersson
- Radiation Protection Dosimetry and Calibrations, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
- Medical Physics Department, Jules Bordet Institute, Université Libre de Bruxelles, Brussels, Belgium
| | - Balázs Madas
- Environmental Physics Department, Centre for Energy Research, Budapest, Hungary
| |
Collapse
|
4
|
Correa-Alfonso CM, Withrow JD, Domal SJ, Xing S, Shin J, Grassberger C, Paganetti H, Bolch WE. A mesh-based model of liver vasculature: implications for improved radiation dosimetry to liver parenchyma for radiopharmaceuticals. EJNMMI Phys 2022; 9:28. [PMID: 35416550 PMCID: PMC9008118 DOI: 10.1186/s40658-022-00456-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 03/28/2022] [Indexed: 12/05/2022] Open
Abstract
Purpose To develop a model of the internal vasculature of the adult liver and demonstrate its application to the differentiation of radiopharmaceutical decay sites within liver parenchyma from those within organ blood. Method Computer-generated models of hepatic arterial (HA), hepatic venous (HV), and hepatic portal venous (HPV) vascular trees were algorithmically created within individual lobes of the ICRP adult female and male livers (AFL/AML). For each iteration of the algorithm, pressure, blood flow, and vessel radii within each tree were updated as each new vessel was created and connected to a viable bifurcation site. The vascular networks created inside the AFL/AML were then tetrahedralized for coupling to the PHITS radiation transport code. Specific absorbed fractions (SAF) were computed for monoenergetic alpha particles, electrons, positrons, and photons. Dual-region liver models of the AFL/AML were proposed, and particle-specific SAF values were computed assuming radionuclide decays in blood within two locations: (1) sites within explicitly modeled hepatic vessels, and (2) sites within the hepatic blood pool residing outside these vessels to include the capillaries and blood sinuses. S values for 22 and 10 radionuclides commonly used in radiopharmaceutical therapy and imaging, respectively, were computed using the dual-region liver models and compared to those obtained in the existing single-region liver model. Results Liver models with virtual vasculatures of ~ 6000 non-intersecting straight cylinders representing the HA, HPV, and HV circulations were created for the ICRP reference. For alpha emitters and for beta and auger-electron emitters, S values using the single-region models were approximately 11% (AML) to 14% (AFL) and 11% (AML) to 13% (AFL) higher than the S values obtained using the dual-region models, respectively. Conclusions The methodology employed in this study has shown improvements in organ parenchymal dosimetry through explicit consideration of blood self-dose for alpha particles (all energies) and for electrons at energies below ~ 100 keV.
Collapse
Affiliation(s)
- Camilo M Correa-Alfonso
- Medical Physics Program, College of Medicine, University of Florida, Gainesville, FL, 32611, USA
| | - Julia D Withrow
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, 32611-6550, USA
| | - Sean J Domal
- Medical Physics Program, College of Medicine, University of Florida, Gainesville, FL, 32611, USA
| | - Shu Xing
- Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Jungwook Shin
- Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02115, USA.,Radiation Epidemiology Branch, National Cancer Institute, Rockville, MD, 21704, USA
| | - Clemens Grassberger
- Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Harald Paganetti
- Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Wesley E Bolch
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, 32611-6550, USA.
| |
Collapse
|
5
|
Mohammadi N, Akhlaghi P. Evaluation of radiation dose to pediatric models from whole body PET/CT imaging. J Appl Clin Med Phys 2022; 23:e13545. [PMID: 35112453 PMCID: PMC8992961 DOI: 10.1002/acm2.13545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 01/10/2022] [Accepted: 01/15/2022] [Indexed: 11/06/2022] Open
Abstract
Positron emission tomography (PET)/computed tomography (CT) is a well-known modality for the diagnosis of various diseases in children and adult patients. On the other hand, younger patients are more radiosensitive than adults, so there are concerns about the level of ionizing radiation exposure in pediatric whole body PET/CT imaging. In this regard, comprehensive specific radiation dosimetry for whole body PET/CT imaging is highly desired for different ages, sizes, and shapes. Therefore, in this study, organ absorbed doses were evaluated for pediatric voxel models from 4 to 14 years old and compared with those of ICRP phantoms. Monte Carlo calculation was performed to evaluate S-value, absorbed dose, and effective dose from 18 F-FDG radiotracers and whole body CT scan for different computational models, including 4- to 14-year-old phantoms. The results showed that the S-value and, therefore, absorbed dose of 18 F-FDG strongly depended on the phantom anatomy. These variations were justified by the distance between source and target organs. Moreover, on average, the absorbed doses from whole body CT scans were 13.5 times lower than those from 18 F-FDG for all organs. According to the results, various anatomies and ages should be considered for accurate dose evaluation. These data can be used for specific risk assessment of the pediatric population in clinical nuclear imaging.
Collapse
Affiliation(s)
- Najmeh Mohammadi
- Faculty of Sciences, Physics Department, Sahand University of Technology, Tabriz, Iran
| | - Parisa Akhlaghi
- Faculty of Medicine, Department of Medical Physics, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
6
|
Akhavanallaf A, Fayad H, Salimi Y, Aly A, Kharita H, Al Naemi H, Zaidi H. An update on computational anthropomorphic anatomical models. Digit Health 2022; 8:20552076221111941. [PMID: 35847523 PMCID: PMC9277432 DOI: 10.1177/20552076221111941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 06/19/2022] [Indexed: 11/15/2022] Open
Abstract
The prevalent availability of high-performance computing coupled with validated
computerized simulation platforms as open-source packages have motivated
progress in the development of realistic anthropomorphic computational models of
the human anatomy. The main application of these advanced tools focused on
imaging physics and computational internal/external radiation dosimetry
research. This paper provides an updated review of state-of-the-art developments
and recent advances in the design of sophisticated computational models of the
human anatomy with a particular focus on their use in radiation dosimetry
calculations. The consolidation of flexible and realistic computational models
with biological data and accurate radiation transport modeling tools enables the
capability to produce dosimetric data reflecting actual setup in clinical
setting. These simulation methodologies and results are helpful resources for
the medical physics and medical imaging communities and are expected to impact
the fields of medical imaging and dosimetry calculations profoundly.
Collapse
Affiliation(s)
- Azadeh Akhavanallaf
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland
| | - Hadi Fayad
- Hamad Medical Corporation, Doha, Qatar
- Weill Cornell Medicine, Doha, Qatar
| | - Yazdan Salimi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland
| | - Antar Aly
- Hamad Medical Corporation, Doha, Qatar
- Weill Cornell Medicine, Doha, Qatar
| | | | - Huda Al Naemi
- Hamad Medical Corporation, Doha, Qatar
- Weill Cornell Medicine, Doha, Qatar
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland
- Geneva University Neurocenter, Geneva University, Geneva, Switzerland
- Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
- Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
7
|
Out-of-field organ doses and associated risk of cancer development following radiation therapy with photons. Phys Med 2021; 90:73-82. [PMID: 34563834 DOI: 10.1016/j.ejmp.2021.09.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/06/2021] [Accepted: 09/13/2021] [Indexed: 11/21/2022] Open
Abstract
Innovations in cancer treatment have contributed to the improved survival rate of these patients. Radiotherapy is one of the main options for cancer management nowadays. High doses of ionizing radiation are usually delivered to the tumor site with high energy photon beams. However, the therapeutic radiation exposure may lead to second cancer induction. Moreover, the introduction of intensity-modulated radiation therapy over the last decades has increased the radiation dose to out-of-field organs compared to that from conventional irradiation. The increased organ doses might result in elevated probabilities for developing secondary malignancies to critical organs outside the treatment volume. The organ-specific dosimetry is considered necessary for the theoretical second cancer risk assessment and the proper analysis of data derived from epidemiological reports. This study reviews the methods employed for the measurement and calculation of out-of-field organ doses from exposure to photons and/or neutrons. The strengths and weaknesses of these dosimetric approaches are described in detail. This is followed by a review of the epidemiological data associated with out-of-field cancer risks. Previously published theoretical cancer risk estimates for adult and pediatric patients undergoing radiotherapy with conventional and advanced techniques are presented. The methodology for the theoretical prediction of the probability of carcinogenesis to out-of-field sites and the limitations of this approach are discussed. The article also focuses on the factors affecting the magnitude of the probability for developing radiotherapy-induced malignancies. The restriction of out-of-field doses and risks through the use of different types of shielding equipment is presented.
Collapse
|
8
|
Bär E, Collins-Fekete CA, Rompokos V, Zhang Y, Gaze MN, Warry A, Poynter A, Royle G. Assessment of the impact of CT calibration procedures for proton therapy planning on pediatric treatments. Med Phys 2021; 48:5202-5218. [PMID: 34174092 DOI: 10.1002/mp.15062] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 06/11/2021] [Accepted: 06/13/2021] [Indexed: 12/30/2022] Open
Abstract
PURPOSE Relative stopping powers (RSPs) for proton therapy are estimated using single-energy computed tomography (SECT), calibrated with standardized tissues of the adult male. It is assumed that those tissues are representative of tissues of all age and sex. Female, male, and pediatric tissues differ from one another in density and composition. In this study, we use tabulated pediatric tissues and computational phantoms to investigate the impact of this assumption on pediatric proton therapy. The potential of dual-energy CT (DECT) to improve the accuracy of these calculations is explored. METHODS We study 51 human body tissues, categorized into male/female for the age groups newborn, 1-, 5-, 10-, and 15-year-old children, and adult, with given compositions and densities. CT numbers are simulated and RSPs are estimated using SECT and DECT methods. Estimated tissue RSPs from each method are compared to theoretical RSPs. The dose and range errors of each approach are evaluated on three computational phantoms (Ewing's sarcoma, salivary sarcoma, and glioma) derived from pediatric proton therapy patients. RESULTS With SECT, soft tissues have mean estimation errors and standard deviation up to (1.96 ± 4.18)% observed in newborns, compared to (0.20 ± 1.15)% in adult males. Mean estimation errors for bones are up to (-3.35 ± 4.76)% in pediatrics as opposed to (0.10 ± 0.66)% in adult males. With DECT, mean errors reduce to (0.17 ± 0.13)% and (0.23 ± 0.22)% in newborns (soft tissues/bones). With SECT, dose errors in a Ewing's sarcoma phantom are exceeding 5 Gy (10% of prescribed dose) at the distal end of the treatment field, with volumes of dose errors >5 Gy ofV diff > 5 = 4630.7 mm3 . Similar observations are made in the head and neck phantoms, with overdoses to healthy tissue exceeding 2 Gy (4%). A systematic Bragg peak shift resulting in either over- or underdosage of healthy tissues and target volumes depending on the crossed tissues RSP prediction errors is observed. Water equivalent range errors of single beams are between -1.53 and 5.50 mm (min, max) (Ewing's sarcoma phantom), -0.78 and 3.62 mm (salivary sarcoma phantom), and -0.43 and 1.41 mm (glioma phantom). DECT can reduce dose errors to <1 Gy and range errors to <1 mm. CONCLUSION Single-energy computed tomography estimates RSPs for pediatric tissues with systematic shifts. DECT improves the accuracy of RSPs and dose distributions in pediatric tissues compared to the SECT calibration curve based on adult male tissues.
Collapse
Affiliation(s)
- Esther Bär
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | | | - Vasilis Rompokos
- Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK
| | - Ying Zhang
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Mark N Gaze
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, UK
| | - Alison Warry
- Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK
| | - Andrew Poynter
- Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK
| | - Gary Royle
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| |
Collapse
|
9
|
Carter LM, Choi C, Krebs S, Beattie BJ, Kim CH, Schoder H, Bolch WE, Kesner AL. Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms. J Nucl Med 2021; 62:jnumed.120.256719. [PMID: 33863823 PMCID: PMC8612182 DOI: 10.2967/jnumed.120.256719] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 03/16/2021] [Accepted: 03/16/2021] [Indexed: 11/16/2022] Open
Abstract
Despite the known influence of anatomic variability on internal dosimetry, dosimetry for 18F-FDG and other diagnostic radiopharmaceuticals is routinely derived using reference phantoms, which embody population-averaged morphometry for a given age and sex. Moreover, phantom format affects dosimetry estimates to varying extent. Here, we applied newly developed mesh format reference phantoms and a patient-dependent phantom library to assess the impact of height, weight, and body contour variation on dosimetry of 18F-FDG. We compared the mesh reference phantom dosimetry estimates with corresponding estimates from common software to identify differences related to phantom format or software implementation. Our study serves as an example of how more precise patient size-dependent dosimetry methodology could be performed. Methods: Absorbed dose coefficients were computed for the adult mesh reference phantoms and derivative patient-dependent phantom series by Monte Carlo simulation using the PHITS radiation transport code within PARaDIM software. The dose coefficients were compared with reference absorbed dose coefficients obtained from ICRP Publication 128, or generated using software including OLINDA 2.1, OLINDA 1.1, and IDAC-dose 2.1. Results: Differences in dosimetry arising from anatomical variations were shown to be significant, with detriment-weighted dose coefficients for the percentile-specific phantoms varying by up to ±40% relative to the corresponding reference phantom effective dose coefficients, irrespective of phantom format. Similar variations were seen in the individual organ absorbed dose coefficients for the percentile-specific phantoms relative to the reference phantoms. The effective dose coefficient for the mesh reference adult was 0.017 mSv/MBq, which was 5% higher than estimated by a corresponding voxel phantom, and 10% lower than estimated by the stylized phantom format. Conclusion: We observed notable variability in 18F-FDG dosimetry across morphometrically different patients, supporting the use of patient-dependent phantoms for more accurate dosimetric estimations relative to standard reference dosimetry. These data may help in optimizing imaging protocols and research studies, in particular when longer-lived isotopes are employed.
Collapse
Affiliation(s)
- Lukas M. Carter
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Chansoo Choi
- Department of Nuclear Engineering, Hanyang University, Seoul, Republic of Korea
| | - Simone Krebs
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York; and
| | - Bradley J. Beattie
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Chan Hyeong Kim
- Department of Nuclear Engineering, Hanyang University, Seoul, Republic of Korea
| | - Heiko Schoder
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York; and
| | - Wesley E. Bolch
- J. Crayton Pruitt Department of Biomedical Engineering, University of Florida, Gainesville, Florida
| | - Adam L. Kesner
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| |
Collapse
|
10
|
Petoussi-Henss N, Satoh D, Schlattl H, Zankl M, Spielmann V. Organ doses of the fetus from external environmental exposures. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2021; 60:93-113. [PMID: 33591375 PMCID: PMC7902579 DOI: 10.1007/s00411-020-00891-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 12/23/2020] [Indexed: 06/12/2023]
Abstract
This article presents nuclide-specific organ dose rate coefficients for environmental external exposures due to soil contamination assumed as a planar source at a depth of 0.5 g cm-2 in the soil and submersion to contaminated air, for a pregnant female and its fetus at the 24th week of gestation. Furthermore, air kerma free-in-air coefficient rates are listed. The coefficients relate the organ equivalent dose rates (Sv s-1) to the activity concentration of environmental sources, in Bq m-2 or Bq m-3, allowing to time-integrate over a particular exposure period. The environmental radiation fields were simulated with the Monte Carlo radiation transport codes PHITS and YURI. Monoenergetic organ dose rate coefficients were calculated employing the Monte Carlo code EGSnrc simulating the photon transport in the voxel phantom of a pregnant female and fetus. Photons of initial energies of 0.015-10 MeV were considered including bremsstrahlung. By folding the monoenergetic dose coefficients with the nuclide decay data, nuclide-specific organ doses were obtained. The results of this work can be employed for estimating the doses from external exposures to pregnant women and their fetus, until more precise data are available which include coefficients obtained for phantoms at different stages of pregnancy.
Collapse
Affiliation(s)
- Nina Petoussi-Henss
- Institute of Radiation Medicine, Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Ingolstaedter Landstr. 1, 85764, Neuherberg, Germany.
| | - Daiki Satoh
- Nuclear Science and Engineering Center, Japan Atomic Energy Agency, Tokai-mura, Ibaraki, 319-1195, Japan
| | - Helmut Schlattl
- Institute of Radiation Medicine, Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Ingolstaedter Landstr. 1, 85764, Neuherberg, Germany
- BfS, German Federal Office for Radiation Protection, Oberschleissheim, Germany
| | - Maria Zankl
- Institute of Radiation Medicine, Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Ingolstaedter Landstr. 1, 85764, Neuherberg, Germany
| | - Vladimir Spielmann
- Institute of Radiation Medicine, Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Ingolstaedter Landstr. 1, 85764, Neuherberg, Germany
- BfS, German Federal Office for Radiation Protection, Oberschleissheim, Germany
| |
Collapse
|
11
|
Radiation dose monitoring in computed tomography: Status, options and limitations. Phys Med 2020; 79:1-15. [DOI: 10.1016/j.ejmp.2020.08.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 07/21/2020] [Accepted: 08/19/2020] [Indexed: 02/02/2023] Open
|
12
|
Kim CH, Yeom YS, Petoussi-Henss N, Zankl M, Bolch WE, Lee C, Choi C, Nguyen TT, Eckerman K, Kim HS, Han MC, Qiu R, Chung BS, Han H, Shin B. ICRP Publication 145: Adult Mesh-Type Reference Computational Phantoms. Ann ICRP 2020; 49:13-201. [PMID: 33231095 DOI: 10.1177/0146645319893605] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
|
13
|
Shahri KK. Estimation of the Effective Dose of Radiation Workers: Optimization Based on the Weight Percentile. HEALTH PHYSICS 2020; 119:273-279. [PMID: 32167496 DOI: 10.1097/hp.0000000000001217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Radiation workers might be exposed to polyenergetic photon radiation beams at different directions in their working environments. In this regard, their effective dose (E) should be accurately estimated using a two-dosimeter algorithm (TDA), based on the measurements of two thermoluminescent dosimeters (TLDs) or film badges that are mounted on the front and back of the body. However, considering different human anatomies, radiation workers may have a variety of weight percentiles. This work sought to find whether TDA obtained for the reference weight percentile (50) can be used for higher weight percentiles (including; 65, 75, 85, and 95). MCNPX was used to simulate different weight percentiles on the revised ORNL phantom by adding extra layers of muscle and adipose on the torso. Then front and back TLD responses were calculated for external beam photon energies of 40 keV to 10 MeV in different irradiation geometries. The results revealed that E value declines with increasing the weight percentile. In this study, three TDA were investigated consisting of Eest = 0.73 Rf + 0.53 Rb (73/53), Eest = 0.55 Rf + 0.50 Rb (55/50), and Eest = 0.70 Rf + 0.30 Rb (70/30). The ratio of Eest/E was calculated for each TDA in different energy bins and weight percentiles. Results obtained using the 55/50 and 70/30 showed higher underestimation for most of the energy bins, especially for PA and AP geometries. Compared to these two TDA, the 73/53 algorithm resulted in higher overestimation for RLAT and LLAT geometries for the same energy bins. Variation of the algorithms showed a similar trend for the studied weight percentiles. To conclude, results obtained by TDA for the 50% weight percentile are applicable for weight percentiles >50%.
Collapse
|
14
|
Josefsson A, Siritantikorn K, Ranka S, de Amorim de Carvalho JW, Buchpiguel CA, Sapienza MT, Bolch WE, Sgouros G. Accuracy in dosimetry of diagnostic agents: impact of the number of source tissues used in whole organ S value-based calculations. EJNMMI Res 2020; 10:26. [PMID: 32189087 PMCID: PMC7080914 DOI: 10.1186/s13550-020-0614-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 02/25/2020] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Dosimetry for diagnostic agents is performed to assess the risk of radiation detriment (e.g., cancer) associated with the imaging agent and the risk is assessed by computing the effective dose coefficient, e. Stylized phantoms created by the MIRD Committee and updated by work performed by Cristy-Eckerman (CE) have been the standard in diagnostic dosimetry. Recently, the ICRP developed voxelized phantoms, which are described in ICRP Publication 110. These voxelized phantoms are more realistic and detailed in describing human anatomy compared with the CE stylized phantoms. Ideally, all tissues should be represented and their pharmacokinetics collected for an as accurate a dosimetric calculation as possible. As the number of source tissues included increases, the calculated e becomes more accurate. There is, however, a trade-off between the number of source tissues considered, and the time and effort required to measure the time-activity curve for each tissue needed for the calculations. In this study, we used a previously published 68Ga-DOTA-TATE data set to examine how the number of source tissues included for both the ICRP voxelized and CE stylized phantoms affected e. RESULTS Depending upon the number of source tissues included e varied between 14.0-23.5 μSv/MBq for the ICRP voxelized and 12.4-27.7 μSv/MBq for the CE stylized phantoms. Furthermore, stability in e, defined as a < 10% difference between e obtained using all source tissues compared to one using fewer source tissues, was obtained after including 5 (36%) of the 14 source tissues for the ICRP voxelized, and after including 3 (25%) of the 12 source tissues for the CE stylized phantoms. In addition, a 2-fold increase in e was obtained when all source tissues where included in the calculation compared to when the TIAC distribution was lumped into a single reminder-of-body source term. CONCLUSIONS This study shows the importance of including the larger tissues like the muscles and remainder-of-body in the dosimetric calculations. The range of e based on the included tissues were less for the ICRP voxelized phantoms using tissue weighting factors from ICRP Publication 103 compared to CE stylized phantoms using tissue weighting factors from ICRP Publication 60.
Collapse
Affiliation(s)
- Anders Josefsson
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, School of Medicine, Baltimore, MD, USA.
| | - Klaikangwol Siritantikorn
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, School of Medicine, Baltimore, MD, USA
| | - Sagar Ranka
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, School of Medicine, Baltimore, MD, USA
| | | | - Carlos Alberto Buchpiguel
- Instituto do Cancer do Estado de São Paulo, São Paulo University, School of Medicine, São Paulo, SP, Brazil
| | - Marcelo Tatit Sapienza
- Instituto do Cancer do Estado de São Paulo, São Paulo University, School of Medicine, São Paulo, SP, Brazil
| | - Wesley E Bolch
- Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - George Sgouros
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, School of Medicine, Baltimore, MD, USA
| |
Collapse
|
15
|
De Mattia C, Campanaro F, Rottoli F, Colombo PE, Pola A, Vanzulli A, Torresin A. Patient organ and effective dose estimation in CT: comparison of four software applications. Eur Radiol Exp 2020; 4:14. [PMID: 32060664 PMCID: PMC7021892 DOI: 10.1186/s41747-019-0130-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Accepted: 11/05/2019] [Indexed: 01/13/2023] Open
Abstract
Background Radiation dose in computed tomography (CT) has become a topic of high interest due to the increasing numbers of CT examinations performed worldwide. Hence, dose tracking and organ dose calculation software are increasingly used. We evaluated the organ dose variability associated with the use of different software applications or calculation methods. Methods We tested four commercial software applications on CT protocols actually in use in our hospital: CT-Expo, NCICT, NCICTX, and Virtual Dose. We compared dose coefficients, estimated organ doses and effective doses obtained by the four software applications by varying exposure parameters. Our results were also compared with estimates reported by the software authors. Results All four software applications showed dependence on tube voltage and volume CT dose index, while only CT-Expo was also dependent on other exposure parameters, in particular scanner model and pitch caused a variability till 50%. We found a disagreement between our results and those reported by the software authors (up to 600%), mainly due to a different extent of examined body regions. The relative range of the comparison of the four software applications was within 35% for most organs inside the scan region, but increased over the 100% for organs partially irradiated and outside the scan region. For effective doses, this variability was less evident (ranging from 9 to 36%). Conclusions The two main sources of organ dose variability were the software application used and the scan region set. Dose estimate must be related to the process used for its calculation.
Collapse
Affiliation(s)
- Cristina De Mattia
- Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore, 3, 20162, Milan, Italy
| | - Federica Campanaro
- Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore, 3, 20162, Milan, Italy
| | - Federica Rottoli
- Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore, 3, 20162, Milan, Italy
| | - Paola Enrica Colombo
- Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore, 3, 20162, Milan, Italy
| | - Andrea Pola
- Department of Energy, Politecnico di Milano, via La Masa, 34, 20156, Milan, Italy
| | - Angelo Vanzulli
- Department of Radiology, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore, 3, 20162, Milan, Italy.
| | - Alberto Torresin
- Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore, 3, 20162, Milan, Italy
| |
Collapse
|
16
|
Shishkina EA, Timofeev YS, Volchkova AY, Sharagin PA, Zalyapin VI, Degteva MO, Smith MA, Napier BA. Trabecula: A Random Generator of Computational Phantoms for Bone Marrow Dosimetry. HEALTH PHYSICS 2020; 118:53-59. [PMID: 31764420 DOI: 10.1097/hp.0000000000001127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This study was motivated by the efforts to evaluate radiation risk for leukemia incidence in the Techa River cohort, where the main bone marrow dose contributors were Sr (bone-seeking beta emitters). Energy deposition in bone marrow targets was evaluated by simulating radiation particle transport using computational phantoms. The present paper describes the computer program Trabecula implementing an algorithm for parametric generation of computational phantoms, which serve as the basis for calculating bone marrow doses. Trabecula is a user-friendly tool that automatically converts analytical models into voxelized representations that are directly compatible as input to Monte Carlo N Particle code.
Collapse
Affiliation(s)
| | - Y S Timofeev
- Urals Research Centre for Radiation Medicine (URCRM), Chelyabinsk, Russia
| | - A Y Volchkova
- Urals Research Centre for Radiation Medicine (URCRM), Chelyabinsk, Russia
| | - P A Sharagin
- Urals Research Centre for Radiation Medicine (URCRM), Chelyabinsk, Russia
| | - V I Zalyapin
- Southern Urals State University (SUSU), Chelyabinsk, Russia
| | - M O Degteva
- Urals Research Centre for Radiation Medicine (URCRM), Chelyabinsk, Russia
| | - M A Smith
- Pacific Northwest National Laboratory, Richland, WA
| | - B A Napier
- Pacific Northwest National Laboratory, Richland, WA
| |
Collapse
|
17
|
Kofler C, Domal S, Satoh D, Dewji S, Eckerman K, Bolch WE. Organ and detriment-weighted dose rate coefficients for exposure to radionuclide-contaminated soil considering body morphometries that differ from reference conditions: adults and children. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2019; 58:477-492. [PMID: 31489486 DOI: 10.1007/s00411-019-00812-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 08/23/2019] [Indexed: 06/10/2023]
Abstract
The system of protection established by the International Commission on Radiological Protection (ICRP) provides a robust framework for ionizing radiation exposure justification, optimization, and dose limitation. The system is built upon fundamental concepts of a reference person, defined in ICRP Publication 89, and the radiation protection quantity effective dose, defined in ICRP Publication 103. For external exposures to radionuclide-contaminated soil, values of the organ dose rate coefficient (Gy/s per Bq/m2) and effective dose rate coefficient (Sv/s per Bq/m2) have been computed by several authors and national laboratories using ICRP-compliant reference phantoms-both stylized and voxelized. These coefficients are of great value in post-accident exposure assessments as seen in Japan following the 2011 Fukushima Daiichi nuclear power station disaster. Questions arise, however, among the general public regarding the accuracy of organ and effective dose estimates based upon reference phantom methodologies, especially for those individuals with height and/or total body mass that differ modestly or even substantially from the nearest age-matched reference person. In this pilot study, this issue is explored through use of the extended 351-member UF/NCI hybrid phantom library in which values of organ and detriment-weighted dose rate coefficients are computed for sex/height/mass-specific phantoms, and systematically compared to their values of the effective dose rate coefficient computed using corresponding reference phantoms. Results are given for monoenergetic photons, and then for some 33 different radionuclides, with all dose rate coefficient data provided in a series of electronic annexes. For environmentally relevant radionuclides such as 89Sr, 90Sr, 137Cs, and 131I, percent differences between the detriment-weighted dose rate coefficient computed using non-reference and the effective dose rate coefficient computed using reference phantoms vary only ± 5% for young children approximated by the reference 1-year-old phantom. With increased body size and age, the range of percent differences in these two quantities increases to + 7% to - 14% for the reference 5-year-old, to + 10% to - 27% for the reference 10-year-old, to + 33% to - 31% for the reference 15-year-old, and to + 15% to - 40% for male and female adults.
Collapse
Affiliation(s)
- Cameron Kofler
- Medical Physics Graduate Program, College of Medicine, University of Florida, Gainesville, FL, USA
| | - Sean Domal
- Medical Physics Graduate Program, College of Medicine, University of Florida, Gainesville, FL, USA
| | - Daiki Satoh
- Nuclear Science and Engineering Center, Japan Atomic Energy Agency, Tokai-mura, Japan
| | - Shaheen Dewji
- Department of Nuclear Engineering, Texas A&M University, College Station, TX, USA
| | - Keith Eckerman
- Center for Radiation Protection Knowledge, Oak Ridge National Laboratory, Oak Ridge, TN, USA
| | - Wesley E Bolch
- J. Crayton Pruitt Family Department of Biomedical Engineering, Department of Biomedical Engineering, University of Florida, Gainesville, FL, 32611-6550, USA.
| |
Collapse
|
18
|
Samei E, Bakalyar D, Boedeker KL, Brady S, Fan J, Leng S, Myers KJ, Popescu LM, Ramirez Giraldo JC, Ranallo F, Solomon J, Vaishnav J, Wang J. Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233. Med Phys 2019; 46:e735-e756. [DOI: 10.1002/mp.13763] [Citation(s) in RCA: 80] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 07/30/2019] [Accepted: 08/08/2019] [Indexed: 11/09/2022] Open
Affiliation(s)
- Ehsan Samei
- Duke University 2424 Erwin Rd Durham NC 27710USA
| | | | | | - Samuel Brady
- Cincinnati Children's Hospital 3333 Burnet Ave Cincinnati OH 45229USA
| | - Jiahua Fan
- GE Healthcare 3000 N. Grandview Blvd Waukesha WI 53188USA
| | - Shuai Leng
- Mayo Clinic 200 1st. St Rochester MN 55901USA
| | - Kyle J. Myers
- Office of Science and Engineering Laboratories FDA 10903 New Hampshire Ave Silver Spring MD 20993USA
| | | | | | - Frank Ranallo
- University of Wisconsin 1111 Highland Ave Madison WI 53705USA
| | - Justin Solomon
- Duke University Medical Center 2424 Erwin Rd Durham NC 27710USA
| | - Jay Vaishnav
- Canon Medical Systems 2441 Michelle Dr Tustin CA 92780USA
| | - Jia Wang
- Stanford University 480 Oak Road Stanford CA 94305USA
| |
Collapse
|
19
|
Wang Z, Balgobind BV, Virgolin M, van Dijk IWEM, Wiersma J, Ronckers CM, Bosman PAN, Bel A, Alderliesten T. How do patient characteristics and anatomical features correlate to accuracy of organ dose reconstruction for Wilms' tumor radiation treatment plans when using a surrogate patient's CT scan? JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2019; 39:598-619. [PMID: 30965301 DOI: 10.1088/1361-6498/ab1796] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In retrospective radiation treatment (RT) dosimetry, a surrogate anatomy is often used for patients without 3D CT. To gain insight in what the crucial aspects in a surrogate anatomy are to enable accurate dose reconstruction, we investigated the relation of patient characteristics and internal anatomical features with deviations in reconstructed organ dose using surrogate patient's CT scans. Abdominal CT scans of 35 childhood cancer patients (age: 2.1-5.6 yr; 17 boys, 18 girls) undergoing RT during 2004-2016 were included. Based on whether an intact right or left kidney is present in the CT scan, two groups were formed each containing 24 patients. From each group, four CTs associated with Wilms' tumor RT plans with an anterior-posterior-posterior-anterior field setup were selected as references. For each reference, a 2D digitally reconstructed radiograph was computed from the reference CT to simulate a 2D radiographic image and dose reconstruction was performed on the other CTs in the respective group. Deviations in organ mean dose (DEmean) of the reconstructions versus the references were calculated, as were deviations in patient characteristics (i.e. age, height, weight) and in anatomical features including organ volume, location (in 3D), and spatial overlaps. Per reference, the Pearson's correlation coefficient between deviations in DEmean and patient characteristics/features were studied. Deviation in organ locations and DEmean for the liver, spleen, and right kidney were moderately correlated (R2 > 0.5) for 8/8, 5/8, and 3/4 reference plans, respectively. Deviations in organ volume or spatial overlap and DEmean for the right and left kidney were weakly correlated (0.3 < R2 < 0.5) in 4/4 and 1/4 reference plans. No correlations (R2 < 0.3) were found between deviations in age or height and DEmean. Therefore, the performance of organ dose reconstruction using surrogate patients' CT scans is primarily related to deviation in organ location, followed by volume and spatial overlap. Further, results were plan dependent.
Collapse
Affiliation(s)
- Ziyuan Wang
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, the Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Baptista M, Di Maria S, Vieira S, Santos J, Pereira J, Pereira M, Vaz P. Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2019; 58:21-37. [PMID: 30392077 DOI: 10.1007/s00411-018-0760-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2018] [Accepted: 10/30/2018] [Indexed: 06/08/2023]
Abstract
Cone-beam computed tomography (CBCT) is widely used for pre-treatment verification and patient setup in image-guided radiation therapy (IGRT). CBCT imaging is employed daily and several times per patient, resulting in potentially high cumulative imaging doses to healthy tissues that surround exposed target organs. Computed tomography dose index (CTDI) is the parameter used by CBCT equipment as indication of the radiation output to patients. This study aimed to increase the knowledge on the relation between CBCT organ doses and weighted CTDI (CTDIW) for a thorax scanning protocol. A CBCT system was modelled using the Monte Carlo (MC) radiation transport program MCNPX2.7.0. Simulation results were validated against half-value layer (HVL), axial beam profile, patient skin dose (PSD) and CTDI measurements. For organ dose calculations, a male voxel phantom ("Golem") was implemented with the CBCT scanner computational model. After a successful MC model validation with measurements, a systematic comparison was performed between organ doses (and their distribution) and CTDI dosimetry concepts [CTDIW and cumulative dose quantities f100(150) and [Formula: see text]]. The results obtained show that CBCT organ doses vary between 1.2 ± 0.1 mGy and 3.3 ± 0.2 mGy for organs located within the primary beam. It was also verified that CTDIW allows prediction of absorbed doses to tissues at distances of about 5 cm from the isocentre of the CBCT system, whereas f100(150) allows prediction of organ doses at distances of about 10 cm from the isocentre, independently from its location. This study demonstrates that these dosimetric concepts are suitable methods that easily allow a good approximation of the additional CBCT imaging doses during a typical lung cancer IGRT treatment.
Collapse
Affiliation(s)
- Mariana Baptista
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066, Bobadela LRS, Portugal.
| | - Salvatore Di Maria
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066, Bobadela LRS, Portugal
| | - Sandra Vieira
- Fundação Champalimaud, Centro Clínico Champalimaud, Avenida de Brasília, 1400-038, Lisbon, Portugal
| | - Joana Santos
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066, Bobadela LRS, Portugal
- Instituto Politécnico de Coimbra, ESTESC, DIMR, Rua 5 de Outubro, 3046-854, Coimbra, Portugal
| | - Joana Pereira
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066, Bobadela LRS, Portugal
- Laboratório de Protecção e Segurança Radiológica, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066, Bobadela LRS, Portugal
| | - Miguel Pereira
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066, Bobadela LRS, Portugal
- Laboratório de Protecção e Segurança Radiológica, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066, Bobadela LRS, Portugal
| | - Pedro Vaz
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10, km 139,7, 2695-066, Bobadela LRS, Portugal
| |
Collapse
|
21
|
George Xu X. Innovations in Computer Technologies Have Impacted Radiation Dosimetry Through Anatomically Realistic Phantoms and Fast Monte Carlo Simulations. HEALTH PHYSICS 2019; 116:263-275. [PMID: 30585974 DOI: 10.1097/hp.0000000000001007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Radiological physics principles have not changed in the past 60 y when computer technologies advanced exponentially. The research field of anatomical modeling for the purpose of radiation dose calculations has experienced an explosion in activity in the past two decades. Such an exciting advancement is due to the feasibility of creating three-dimensional geometric details of the human anatomy from tomographic imaging and of performing Monte Carlo radiation transport simulations on increasingly fast and cheap personal computers. The advent of a new type of high-performance computing hardware in recent years-graphics processing units-has made it feasible to carry out time-consuming Monte Carlo calculations at near real-time speeds. This paper introduces the history of three generations of computational human phantoms (the stylized medical internal radiation dosimetry-type phantoms, the voxelized tomographic phantoms, and the boundary representation deformable phantoms) and new development of the graphics processing unit-based Monte Carlo radiation dose calculations. Examples are given for research projects performed by my students in applying computational phantoms and a new Monte Carlo code, ARCHER, to problems in radiation protection, imaging, and radiotherapy. Finally, the paper discusses challenges and future opportunities for research.
Collapse
Affiliation(s)
- X George Xu
- JEC 5049, Rensselaer Polytechnic Institute, 110 8th St., Troy, NY 12180
| |
Collapse
|
22
|
Becker J, Fedrigo M. Introducing the Concept of Potential-Based Organ Contours. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2019. [DOI: 10.1109/trpms.2018.2829266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
23
|
Kainz W, Neufeld E, Bolch WE, Graff CG, Kim CH, Kuster N, Lloyd B, Morrison T, Segars P, Yeom YS, Zankl M, Xu XG, Tsui BMW. Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2019; 3:1-23. [PMID: 30740582 PMCID: PMC6362464 DOI: 10.1109/trpms.2018.2883437] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Over the past decades, significant improvements have been made in the field of computational human phantoms (CHPs) and their applications in biomedical engineering. Their sophistication has dramatically increased. The very first CHPs were composed of simple geometric volumes, e.g., cylinders and spheres, while current CHPs have a high resolution, cover a substantial range of the patient population, have high anatomical accuracy, are poseable, morphable, and are augmented with various details to perform functionalized computations. Advances in imaging techniques and semi-automated segmentation tools allow fast and personalized development of CHPs. These advances open the door to quickly develop personalized CHPs, inherently including the disease of the patient. Because many of these CHPs are increasingly providing data for regulatory submissions of various medical devices, the validity, anatomical accuracy, and availability to cover the entire patient population is of utmost importance. The article is organized into two main sections: the first section reviews the different modeling techniques used to create CHPs, whereas the second section discusses various applications of CHPs in biomedical engineering. Each topic gives an overview, a brief history, recent developments, and an outlook into the future.
Collapse
Affiliation(s)
- Wolfgang Kainz
- Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, MD 20993 USA
| | - Esra Neufeld
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland
| | | | - Christian G Graff
- Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, MD 20993 USA
| | | | - Niels Kuster
- Swiss Federal Institute of Technology, ETH Zürich, and the Foundation for Research on Information Technologies in Society (IT'IS), Zürich, Switzerland
| | - Bryn Lloyd
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland
| | - Tina Morrison
- Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, MD 20993 USA
| | | | | | - Maria Zankl
- Helmholtz Zentrum München German Research Center for Environmental Health, Munich, Germany
| | - X George Xu
- Rensselaer Polytechnic Institute, Troy, NY, USA
| | | |
Collapse
|
24
|
Three-Dimensional Printing for Construction of Tissue-Equivalent Anthropomorphic Phantoms and Determination of Conceptus Dose. AJR Am J Roentgenol 2018; 211:1283-1290. [PMID: 30354270 DOI: 10.2214/ajr.17.19489] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to develop a road map for rapid construction of anthropomorphic phantoms from computational human phantoms for use in diagnostic imaging dosimetry studies. These phantoms are ideal for performing pregnant-patient dosimetry because the phantoms imitate the size and attenuation properties of an average-sized pregnant woman for multiple gestational periods. MATERIALS AND METHODS The method was derived from methods and materials previously described but adapted for 3D printing technology. A 3D printer was used to transform computational models into a physical duplicate with small losses in spatial accuracy and to generate tissue-equivalent materials characterized for diagnostic energy x-rays. A series of pregnant abdomens were selected as prototypes because of their large size and complex modeling. The process involved the following steps: segmentation of anatomy used for modeling; transformation of the computational model into a printing file format; preparation, characterization, and introduction of phantom materials; and model removal and phantom assembly. RESULTS The density of the homogenized soft tissue-equivalent substitute was optimized by combining 9.0% by weight of urethane filler powder and 91.0% urethane polymer, which resulted in a mean density of 1.041 g/cm3 measured over 20 samples. Density varied among all of the samples by 0.0026 g/cm3. The total variation in density was 0.00261 g/cm3. The half-value layer of the bone material was measured to be 1.7 mm of bone material at 120 kVp and when simulated by use of the density of the bone tissue-equivalent substitute (1.60 g/cm3) was determined to be 1.61 mm of bone tissue. For dosimetry purposes the phantom provided excellent results for evaluating a site's protocol based on scan range. CONCLUSION The 3D printing technology is applicable to the fabrication of phantoms used for performing dosimetry. The tissue-equivalent materials used to substitute for the soft tissue were developed to be highly adaptable for optimization based on the dosimetry application. Use of this method resulted in more automated phantom construction with decreased construction time and increased out-of-slice spatial resolution of the phantoms.
Collapse
|
25
|
Wayson MB, Bolch WE. Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient internal anatomy. Phys Med Biol 2018; 63:085006. [PMID: 29546844 DOI: 10.1088/1361-6560/aab730] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Various computational tools are currently available that facilitate patient organ dosimetry in diagnostic nuclear medicine, yet they are typically restricted to reporting organ doses to ICRP-defined reference phantoms. The present study, while remaining computational phantom based, provides straightforward tools to adjust reference phantom organ dose for both internal photon and electron sources. A wide variety of monoenergetic specific absorbed fractions were computed using radiation transport simulations for tissue spheres of varying size and separation distance. Scaling methods were then constructed for both photon and electron self-dose and cross-dose, with data validation provided from patient-specific voxel phantom simulations, as well as via comparison to the scaling methodology given in MIRD Pamphlet No. 11. Photon and electron self-dose was found to be dependent on both radiation energy and sphere size. Photon cross-dose was found to be mostly independent of sphere size. Electron cross-dose was found to be dependent on sphere size when the spheres were in close proximity, owing to differences in electron range. The validation studies showed that this dataset was more effective than the MIRD 11 method at predicting patient-specific photon doses for at both high and low energies, but gave similar results at photon energies between 100 keV and 1 MeV. The MIRD 11 method for electron self-dose scaling was accurate for lower energies but began to break down at higher energies. The photon cross-dose scaling methodology developed in this study showed gains in accuracy of up to 9% for actual patient studies, and the electron cross-dose scaling methodology showed gains in accuracy up to 9% as well when only the bremsstrahlung component of the cross-dose was scaled. These dose scaling methods are readily available for incorporation into internal dosimetry software for diagnostic phantom-based organ dosimetry.
Collapse
Affiliation(s)
- Michael B Wayson
- Present address: Medical Physics and Radiation Safety, Baylor Scott and White Health, 3500 Gaston Avenue Dallas, TX 75246, United States of America
| | | |
Collapse
|
26
|
Wang Z, van Dijk IWEM, Wiersma J, Ronckers CM, Oldenburger F, Balgobind BV, Bosman PAN, Bel A, Alderliesten T. Are age and gender suitable matching criteria in organ dose reconstruction using surrogate childhood cancer patients' CT scans? Med Phys 2018; 45:2628-2638. [PMID: 29637577 DOI: 10.1002/mp.12908] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 03/19/2018] [Accepted: 03/27/2018] [Indexed: 12/25/2022] Open
Abstract
PURPOSE The purpose of this work was to assess the feasibility of using surrogate CT scans of matched patients for organ dose reconstructions for childhood cancer (CC) survivors, treated in the past with only 2D imaging data available instead of 3D CT data, and in particular using the current literature standard of matching patients based on similarity in age and gender. METHODS Thirty-one recently treated CC patients with abdominal CT scans were divided into six age- and gender-matched groups. From each group, two radiotherapy plans for Wilms' tumor were selected as reference plans and applied to the age- and gender-matched patients' CTs in the respective group. Two reconstruction strategies were investigated: S1) without field adjustments; S2) with manual field adjustments according to anatomical information, using a visual check in digitally reconstructed radiographs. To assess the level of agreement between the reconstructed and the reference dose distributions, we computed (using a collapsed cone algorithm) and compared the absolute deviation in mean and maximum dose normalized by the prescribed dose (i.e., normalized errors |NEmean | and |NE2cc |) in eight organs at risk (OARs): heart, lungs, liver, spleen, kidneys, and spinal cord. Furthermore, we assessed the quality of a reconstruction case by varying acceptance thresholds for |NEmean | and |NE2cc |. A reconstruction case was accepted (i.e., considered to pass) if the errors in all OARs are smaller than the threshold. The pass fraction for a given threshold was then defined as the percentage of reconstruction cases that were classified as a pass. Furthermore, we consider the impact of allowing to use a different CT scan for each OAR. RESULTS Slightly smaller reconstruction errors were achieved with S2 in multiple OARs than with S1 (P < 0.05). Among OARs, the best reconstruction was found for the spinal cord (average |NEmean | and |NE2cc | ≤ 4%). The largest average |NEmean | was found in the spleen (18%). The largest average |NE2cc | was found in the left lung (26%). Less than 30% of the reconstruction cases (i.e., pass fraction) meet the criteria that |NEmean | < 20% and |NE2cc | < 20% in all OARs when using age and gender matching and a single CT to do reconstructions. Allowing other matchings and combining reconstructions for OARs from multiple patients, the pass fraction increases substantially to more than 60%. CONCLUSIONS To conclude, reconstructions with small deviations can be obtained by using CC patients' CT scans, making the general approach promising. However, using age and gender as the only matching criteria to select a CT scan for the reconstruction is not sufficient to guarantee sufficiently low reconstruction errors. It is therefore suggested to include more features (e.g., height, features extracted from 2D radiographs) than only age and gender for dose reconstruction for CC survivors treated in the pre-3D radiotherapy planning era and to consider ways to combine multiple reconstructions focused on different OARs.
Collapse
Affiliation(s)
- Ziyuan Wang
- Department of Radiation Oncology, Academic Medical Center (AMC), Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Irma W E M van Dijk
- Department of Radiation Oncology, Academic Medical Center (AMC), Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Jan Wiersma
- Department of Radiation Oncology, Academic Medical Center (AMC), Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Cécile M Ronckers
- Department of Pediatric Oncology, Emma Children's Hospital/AMC, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Foppe Oldenburger
- Department of Radiation Oncology, Academic Medical Center (AMC), Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Brian V Balgobind
- Department of Radiation Oncology, Academic Medical Center (AMC), Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Peter A N Bosman
- Centrum Wiskunde & Informatica (CWI), Science Park 123, 1098 XG, Amsterdam, The Netherlands
| | - Arjan Bel
- Department of Radiation Oncology, Academic Medical Center (AMC), Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Tanja Alderliesten
- Department of Radiation Oncology, Academic Medical Center (AMC), Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| |
Collapse
|
27
|
Baptista M, Di Maria S, Vieira S, Vaz P. Entrance surface dose distribution and organ dose assessment for cone-beam computed tomography using measurements and Monte Carlo simulations with voxel phantoms. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.02.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
28
|
Zvereva A, Schlattl H, Zankl M, Becker J, Petoussi-Henss N, Yeom YS, Kim CH, Hoeschen C, Parodi K. Feasibility of reducing differences in estimated doses in nuclear medicine between a patient-specific and a reference phantom. Phys Med 2017. [PMID: 28624290 DOI: 10.1016/j.ejmp.2017.06.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
The feasibility of reducing the differences between patient-specific internal doses and doses estimated using reference phantoms was evaluated. Relatively simple adjustments to a polygon-surface ICRP adult male reference phantom were applied to fit selected individual dimensions using the software Rhinoceros®4.0. We tested this approach on two patient-specific phantoms: the biggest and the smallest phantoms from the Helmholtz Zentrum München library. These phantoms have unrelated anatomy and large differences in body-mass-index. Three models approximating each patient's anatomy were considered: the voxel and the polygon-surface ICRP adult male reference phantoms and the adjusted polygon-surface reference phantom. The Specific Absorbed Fractions (SAFs) for internal photon and electron sources were calculated with the Monte Carlo code EGSnrc. Employing the time-integrated activity coefficients of a radiopharmaceutical (S)-4-(3-18F-fluoropropyl)-l-glutamic acid and the calculated SAFs, organ absorbed-dose coefficients were computed following the formalism promulgated by the Committee on Medical Internal Radiation Dose. We compared the absorbed-dose coefficients between each patient-specific phantom and other models considered with emphasis on the cross-fire component. The corresponding differences for most organs were notably lower for the adjusted reference models compared to the case when reference models were employed. Overall, the proposed approach provided reliable dose estimates for both tested patient-specific models despite the pronounced differences in their anatomy. To capture the full range of inter-individual anatomic variability more patient-specific phantoms are required. The results of this test study suggest a feasibility of estimating patient-specific doses within a relative uncertainty of 25% or less using adjusted reference models, when only simple phantom scaling is applied.
Collapse
Affiliation(s)
- Alexandra Zvereva
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany; Ludwig Maximilians Universität München (LMU Munich), Experimental Physics - Medical Physics, Am Coulombwall 1, 85748 Garching, Germany.
| | - Helmut Schlattl
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany
| | - Maria Zankl
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany
| | - Janine Becker
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany
| | - Nina Petoussi-Henss
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany
| | - Yeon Soo Yeom
- Department of Nuclear Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, 04763 Seoul, Republic of Korea
| | - Chan Hyeong Kim
- Department of Nuclear Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, 04763 Seoul, Republic of Korea
| | - Christoph Hoeschen
- Otto von Guericke Universität Magdeburg, Institut für Medizintechnik, Universitätsplatz 2, 39104 Magdeburg, Germany
| | - Katia Parodi
- Ludwig Maximilians Universität München (LMU Munich), Experimental Physics - Medical Physics, Am Coulombwall 1, 85748 Garching, Germany
| |
Collapse
|
29
|
Khankook AE, Hakimabad HM, Motavalli LR. A feasibility study on the use of phantoms with statistical lung masses for determining the uncertainty in the dose absorbed by the lung from broad beams of incident photons and neutrons. JOURNAL OF RADIATION RESEARCH 2017; 58:313-328. [PMID: 28077627 PMCID: PMC5440861 DOI: 10.1093/jrr/rrw118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2016] [Revised: 08/24/2016] [Indexed: 06/06/2023]
Abstract
Computational models of the human body have gradually become crucial in the evaluation of doses absorbed by organs. However, individuals may differ considerably in terms of organ size and shape. In this study, the authors sought to determine the energy-dependent standard deviations due to lung size of the dose absorbed by the lung during external photon and neutron beam exposures. One hundred lungs with different masses were prepared and located in an adult male International Commission on Radiological Protection (ICRP) reference phantom. Calculations were performed using the Monte Carlo N-particle code version 5 (MCNP5). Variation in the lung mass caused great uncertainty: ~90% for low-energy broad parallel photon beams. However, for high-energy photons, the lung-absorbed dose dependency on the anatomical variation was reduced to <1%. In addition, the results obtained indicated that the discrepancy in the lung-absorbed dose varied from 0.6% to 8% for neutron beam exposure. Consequently, the relationship between absorbed dose and organ volume was found to be significant for low-energy photon sources, whereas for higher energy photon sources the organ-absorbed dose was independent of the organ volume. In the case of neutron beam exposure, the maximum discrepancy (of 8%) occurred in the energy range between 0.1 and 5 MeV.
Collapse
Affiliation(s)
- Atiyeh Ebrahimi Khankook
- Physics Department, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad 91775-1436, Iran
| | - Hashem Miri Hakimabad
- Physics Department, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad 91775-1436, Iran
| | - Laleh Rafat Motavalli
- Physics Department, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad 91775-1436, Iran
| |
Collapse
|
30
|
Petoussi-Henss N, Schlattl H, Becker J, Greiter M, Zankl M, Hoeschen C. Anthropomorphic dual-lattice voxel models for optimizing image quality and dose. J Med Imaging (Bellingham) 2017; 4:013509. [PMID: 28401175 PMCID: PMC5373163 DOI: 10.1117/1.jmi.4.1.013509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Accepted: 03/14/2017] [Indexed: 11/13/2023] Open
Abstract
Using numerical simulations, the influence of various imaging parameters on the resulting image can be determined for various imaging technologies. To achieve this, visualization of fine tissue structures needed to evaluate the image quality with different radiation quality and dose is essential. The present work examines a method that employs simulations of the imaging process using Monte Carlo methods and a combination of a standard and higher resolution voxel models. A hybrid model, based on nonlinear uniform rational B-spline and polygon mesh surfaces, was constructed from an existing voxel model of a female patient of a resolution in the range of millimeters. The resolution of the hybrid model was [Formula: see text], i.e., substantially finer than that of the original model. Furthermore, a high resolution lung voxel model [[Formula: see text] voxel volume, slice thickness: [Formula: see text]] was developed from the specimen of a left lung lobe. This has been inserted into the hybrid model, substituting its left lung lobe and resulting in a dual-lattice geometry model. "Dual lattice" means, in this context, the combination of voxel models with different resolutions. Monte Carlo simulations of radiographic imaging were performed and the fine structure of the lung was easily recognizable.
Collapse
Affiliation(s)
- Nina Petoussi-Henss
- Institute of Radiation Protection, Helmholtz Zentrum München, Neuherberg, Germany
| | - Helmut Schlattl
- Institute of Radiation Protection, Helmholtz Zentrum München, Neuherberg, Germany
| | - Janine Becker
- Institute of Radiation Protection, Helmholtz Zentrum München, Neuherberg, Germany
| | - Matthias Greiter
- Individual Monitoring Service, Helmholtz Zentrum München, Neuherberg, Germany
| | - Maria Zankl
- Institute of Radiation Protection, Helmholtz Zentrum München, Neuherberg, Germany
| | - Christoph Hoeschen
- Otto-von-Guericke University, Medical Systems, Institute of Medical Technology, Magdeburg, Germany
| |
Collapse
|
31
|
Mattsson S. NEED FOR INDIVIDUAL CANCER RISK ESTIMATES IN X-RAY AND NUCLEAR MEDICINE IMAGING. RADIATION PROTECTION DOSIMETRY 2016; 169:11-16. [PMID: 26994092 DOI: 10.1093/rpd/ncw034] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
To facilitate the justification of an X-ray or nuclear medicine investigation and for informing patients, it is desirable that the individual patient's radiation dose and potential cancer risk can be prospectively assessed and documented. The current dose-reporting is based on effective dose, which ignores body size and does not reflect the strong dependence of risk on the age at exposure. Risk estimations should better be done through individual organ dose assessments, which need careful exposure characterisation as well as anatomical description of the individual patient. In nuclear medicine, reference biokinetic models should also be replaced with models describing individual physiological states and biokinetics. There is a need to adjust population-based cancer risk estimates to the possible risk of leukaemia and solid tumours for the individual depending on age and gender. The article summarises reasons for individual cancer risk estimates and gives examples of methods and results of such estimates.
Collapse
Affiliation(s)
- Sören Mattsson
- Medical Radiation Physics Malmö, Department of Translational Medicine, Lund University, Malmö, Sweden
| |
Collapse
|
32
|
Ding A, Gao Y, Liu H, Caracappa PF, Long DJ, Bolch WE, Liu B, Xu XG. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients. Phys Med Biol 2015; 60:5601-25. [DOI: 10.1088/0031-9155/60/14/5601] [Citation(s) in RCA: 72] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
33
|
Baptista M, Di Maria S, Barros S, Figueira C, Sarmento M, Orvalho L, Vaz P. Dosimetric characterization and organ dose assessment in digital breast tomosynthesis: Measurements and Monte Carlo simulations using voxel phantoms. Med Phys 2015; 42:3788-800. [DOI: 10.1118/1.4921362] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
34
|
Giussani A. Models and phantoms for internal dose assessment. RADIATION PROTECTION DOSIMETRY 2015; 164:46-50. [PMID: 25305216 DOI: 10.1093/rpd/ncu313] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Radiation doses delivered by incorporated radionuclides cannot be directly measured, and they are assessed by means of biokinetic and dosimetric models and computational phantoms. For emitters of short-range radiation like alpha-particles or Auger electrons, the doses at organ levels, as they are usually defined in internal dosimetry, are no longer relevant. Modelling the inter- and intra-cellular radiation transport and the local patterns of deposition at molecular or cellular levels are the challenging tasks of micro- and nano-dosimetry. With time, the physiological and anatomical realism of the models and phantoms have increased. However, not always the information is available that would be required to characterise the greater complexity of the recent models. Uncertainty studies in internal dose assessment provide here a valuable contribution for testing the significance of the new dose estimates and of the discrepancies from the previous values. Some of the challenges, limitations and future perspectives of the use of models and phantoms in internal dosimetry are discussed in the present manuscript.
Collapse
Affiliation(s)
- Augusto Giussani
- Department of Radiation and Health, BfS-Federal Office for Radiation Protection, Ingolstädter Landstr. 1, Oberschleißheim 85764, Germany
| |
Collapse
|
35
|
Xie T, Zaidi H. Effect of respiratory motion on internal radiation dosimetry. Med Phys 2014; 41:112506. [DOI: 10.1118/1.4898118] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
36
|
Fonseca TCF, Bogaerts R, Hunt J, Vanhavere F. A methodology to develop computational phantoms with adjustable posture for WBC calibration. Phys Med Biol 2014; 59:6811-25. [DOI: 10.1088/0031-9155/59/22/6811] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
37
|
Xu XG. An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history. Phys Med Biol 2014; 59:R233-302. [PMID: 25144730 PMCID: PMC4169876 DOI: 10.1088/0031-9155/59/18/r233] [Citation(s) in RCA: 161] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Radiation dose calculation using models of the human anatomy has been a subject of great interest to radiation protection, medical imaging, and radiotherapy. However, early pioneers of this field did not foresee the exponential growth of research activity as observed today. This review article walks the reader through the history of the research and development in this field of study which started some 50 years ago. This review identifies a clear progression of computational phantom complexity which can be denoted by three distinct generations. The first generation of stylized phantoms, representing a grouping of less than dozen models, was initially developed in the 1960s at Oak Ridge National Laboratory to calculate internal doses from nuclear medicine procedures. Despite their anatomical simplicity, these computational phantoms were the best tools available at the time for internal/external dosimetry, image evaluation, and treatment dose evaluations. A second generation of a large number of voxelized phantoms arose rapidly in the late 1980s as a result of the increased availability of tomographic medical imaging and computers. Surprisingly, the last decade saw the emergence of the third generation of phantoms which are based on advanced geometries called boundary representation (BREP) in the form of Non-Uniform Rational B-Splines (NURBS) or polygonal meshes. This new class of phantoms now consists of over 287 models including those used for non-ionizing radiation applications. This review article aims to provide the reader with a general understanding of how the field of computational phantoms came about and the technical challenges it faced at different times. This goal is achieved by defining basic geometry modeling techniques and by analyzing selected phantoms in terms of geometrical features and dosimetric problems to be solved. The rich historical information is summarized in four tables that are aided by highlights in the text on how some of the most well-known phantoms were developed and used in practice. Some of the information covered in this review has not been previously reported, for example, the CAM and CAF phantoms developed in 1970s for space radiation applications. The author also clarifies confusion about 'population-average' prospective dosimetry needed for radiological protection under the current ICRP radiation protection system and 'individualized' retrospective dosimetry often performed for medical physics studies. To illustrate the impact of computational phantoms, a section of this article is devoted to examples from the author's own research group. Finally the author explains an unexpected finding during the course of preparing for this article that the phantoms from the past 50 years followed a pattern of exponential growth. The review ends on a brief discussion of future research needs (a supplementary file '3DPhantoms.pdf' to figure 15 is available for download that will allow a reader to interactively visualize the phantoms in 3D).
Collapse
Affiliation(s)
- X George Xu
- Rensselaer Polytechnic Institute Troy, New York, USA
| |
Collapse
|
38
|
Fonseca TCF, Bogaerts R, Lebacq AL, Mihailescu CL, Vanhavere F. Study of the counting efficiency of a WBC setup by using a computational 3D human body library in sitting position based on polygonal mesh surfaces. HEALTH PHYSICS 2014; 106:484-493. [PMID: 24562069 DOI: 10.1097/hp.0b013e3182a414ba] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A realistic computational 3D human body library, called MaMP and FeMP (Male and Female Mesh Phantoms), based on polygonal mesh surface geometry, has been created to be used for numerical calibration of the whole body counter (WBC) system of the nuclear power plant (NPP) in Doel, Belgium. The main objective was to create flexible computational models varying in gender, body height, and mass for studying the morphology-induced variation of the detector counting efficiency (CE) and reducing the measurement uncertainties. First, the counting room and an HPGe detector were modeled using MCNPX (Monte Carlo radiation transport code). The validation of the model was carried out for different sample-detector geometries with point sources and a physical phantom. Second, CE values were calculated for a total of 36 different mesh phantoms in a seated position using the validated Monte Carlo model. This paper reports on the validation process of the in vivo whole body system and the CE calculated for different body heights and weights. The results reveal that the CE is strongly dependent on the individual body shape, size, and gender and may vary by a factor of 1.5 to 3 depending on the morphology aspects of the individual to be measured.
Collapse
Affiliation(s)
- T C Ferreira Fonseca
- *Belgian Nuclear Research Centre-SCK-CEN, Boeretang, 200 Mol, 2400, Belgium; †University Hospital Gasthuisberg, Department of Radiation Oncology, Herestraat 49, B-3000, Leuven, Belgium
| | | | | | | | | |
Collapse
|
39
|
Moignier A, Derreumaux S, Broggio D, Beurrier J, Chea M, Boisserie G, Franck D, Aubert B, Mazeron JJ. Potential of hybrid computational phantoms for retrospective heart dosimetry after breast radiation therapy: a feasibility study. Int J Radiat Oncol Biol Phys 2012; 85:492-9. [PMID: 22608886 DOI: 10.1016/j.ijrobp.2012.03.037] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2011] [Revised: 02/08/2012] [Accepted: 03/10/2012] [Indexed: 11/27/2022]
Abstract
PURPOSE Current retrospective cardiovascular dosimetry studies are based on a representative patient or simple mathematic phantoms. Here, a process of patient modeling was developed to personalize the anatomy of the thorax and to include a heart model with coronary arteries. METHODS AND MATERIALS The patient models were hybrid computational phantoms (HCPs) with an inserted detailed heart model. A computed tomography (CT) acquisition (pseudo-CT) was derived from HCP and imported into a treatment planning system where treatment conditions were reproduced. Six current patients were selected: 3 were modeled from their CT images (A patients) and the others were modelled from 2 orthogonal radiographs (B patients). The method performance and limitation were investigated by quantitative comparison between the initial CT and the pseudo-CT, namely, the morphology and the dose calculation were compared. For the B patients, a comparison with 2 kinds of representative patients was also conducted. Finally, dose assessment was focused on the whole coronary artery tree and the left anterior descending coronary. RESULTS When 3-dimensional anatomic information was available, the dose calculations performed on the initial CT and the pseudo-CT were in good agreement. For the B patients, comparison of doses derived from HCP and representative patients showed that the HCP doses were either better or equivalent. In the left breast radiation therapy context and for the studied cases, coronary mean doses were at least 5-fold higher than heart mean doses. CONCLUSIONS For retrospective dose studies, it is suggested that HCP offers a better surrogate, in terms of dose accuracy, than representative patients. The use of a detailed heart model eliminates the problem of identifying the coronaries on the patient's CT.
Collapse
Affiliation(s)
- Alexandra Moignier
- Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France.
| | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Moteabbed M, Geyer A, Drenkhahn R, Bolch WE, Paganetti H. Comparison of whole-body phantom designs to estimate organ equivalent neutron doses for secondary cancer risk assessment in proton therapy. Phys Med Biol 2012; 57:499-515. [DOI: 10.1088/0031-9155/57/2/499] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
41
|
Miller DL, Balter S, Dixon RG, Nikolic B, Bartal G, Cardella JF, Dauer LT, Stecker MS. Quality improvement guidelines for recording patient radiation dose in the medical record for fluoroscopically guided procedures. J Vasc Interv Radiol 2011; 23:11-8. [PMID: 22057151 DOI: 10.1016/j.jvir.2011.09.004] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2011] [Revised: 09/08/2011] [Accepted: 09/08/2011] [Indexed: 10/15/2022] Open
Affiliation(s)
- Donald L Miller
- Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Parach AA, Rajabi H, Askari MA. Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2011; 50:441-450. [PMID: 21573984 DOI: 10.1007/s00411-011-0370-0] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2011] [Accepted: 05/01/2011] [Indexed: 05/30/2023]
Abstract
GATE/GEANT is a Monte Carlo code dedicated to nuclear medicine that allows calculation of the dose to organs of voxel phantoms. On the other hand, MIRD is a well-developed system for estimation of the dose to human organs. In this study, results obtained from GATE/GEANT using Snyder phantom are compared to published MIRD data. For this, the mathematical Snyder phantom was discretized and converted to a digital phantom of 100 × 200 × 360 voxels. The activity was considered uniformly distributed within kidneys, liver, lungs, pancreas, spleen, and adrenals. The GATE/GEANT Monte Carlo code was used to calculate the dose to the organs of the phantom from mono-energetic photons of 10, 15, 20, 30, 50, 100, 200, 500, and 1000 keV. The dose was converted into specific absorbed fraction (SAF) and the results were compared to the corresponding published MIRD data. On average, there was a good correlation (r (2)>0.99) between the two series of data. However, the GATE/GEANT data were on average -0.16 ± 6.22% lower than the corresponding MIRD data for self-absorption. Self-absorption in the lungs was considerably higher in the MIRD compared to the GATE/GEANT data, for photon energies of 10-20 keV. As for cross-irradiation to other organs, the GATE/GEANT data were on average +1.5 ± 8.1% higher than the MIRD data, for photon energies of 50-1000 keV. For photon energies of 10-30 keV, the relative difference was +7.5 ± 67%. It turned out that the agreement between the GATE/GEANT and the MIRD data depended upon absolute SAF values and photon energy. For 10-30 keV photons, where the absolute SAF values were small, the uncertainty was high and the effect of cross-section prominent, and there was no agreement between the GATE/GEANT results and the MIRD data. However, for photons of 50-1,000 keV, the bias was negligible and the agreement was acceptable.
Collapse
Affiliation(s)
- Ali Asghar Parach
- Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, P.O. Box 14115-331, Tehran, Iran
| | | | | |
Collapse
|
43
|
Maynard MR, Geyer JW, Aris JP, Shifrin RY, Bolch W. The UF family of hybrid phantoms of the developing human fetus for computational radiation dosimetry. Phys Med Biol 2011; 56:4839-79. [PMID: 21765203 DOI: 10.1088/0031-9155/56/15/014] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Historically, the development of computational phantoms for radiation dosimetry has primarily been directed at capturing and representing adult and pediatric anatomy, with less emphasis devoted to models of the human fetus. As concern grows over possible radiation-induced cancers from medical and non-medical exposures of the pregnant female, the need to better quantify fetal radiation doses, particularly at the organ-level, also increases. Studies such as the European Union's SOLO (Epidemiological Studies of Exposed Southern Urals Populations) hope to improve our understanding of cancer risks following chronic in utero radiation exposure. For projects such as SOLO, currently available fetal anatomic models do not provide sufficient anatomical detail for organ-level dose assessment. To address this need, two fetal hybrid computational phantoms were constructed using high-quality magnetic resonance imaging and computed tomography image sets obtained for two well-preserved fetal specimens aged 11.5 and 21 weeks post-conception. Individual soft tissue organs, bone sites and outer body contours were segmented from these images using 3D-DOCTOR™ and then imported to the 3D modeling software package Rhinoceros™ for further modeling and conversion of soft tissue organs, certain bone sites and outer body contours to deformable non-uniform rational B-spline surfaces. The two specimen-specific phantoms, along with a modified version of the 38 week UF hybrid newborn phantom, comprised a set of base phantoms from which a series of hybrid computational phantoms was derived for fetal ages 8, 10, 15, 20, 25, 30, 35 and 38 weeks post-conception. The methodology used to construct the series of phantoms accounted for the following age-dependent parameters: (1) variations in skeletal size and proportion, (2) bone-dependent variations in relative levels of bone growth, (3) variations in individual organ masses and total fetal masses and (4) statistical percentile variations in skeletal size, individual organ masses and total fetal masses. The resulting series of fetal hybrid computational phantoms is applicable to organ-level and bone-level internal and external radiation dosimetry for human fetuses of various ages and weight percentiles.
Collapse
Affiliation(s)
- Matthew R Maynard
- Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL, USA
| | | | | | | | | |
Collapse
|
44
|
Dauer LT, Thornton R, Boylan DC, Holahan B, Prins R, Quinn B, St. Germain J. Organ and effective dose estimates for patients undergoing hepatic arterial embolization for treatment of liver malignancy. Med Phys 2011; 38:736-42. [DOI: 10.1118/1.3533685] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
45
|
Hricak H, Brenner DJ, Adelstein SJ, Frush DP, Hall EJ, Howell RW, McCollough CH, Mettler FA, Pearce MS, Suleiman OH, Thrall JH, Wagner LK. Managing radiation use in medical imaging: a multifaceted challenge. Radiology 2010; 258:889-905. [PMID: 21163918 DOI: 10.1148/radiol.10101157] [Citation(s) in RCA: 236] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
This special report aims to inform the medical community about the many challenges involved in managing radiation exposure in a way that maximizes the benefit-risk ratio. The report discusses the state of current knowledge and key questions in regard to sources of medical imaging radiation exposure, radiation risk estimation, dose reduction strategies, and regulatory options.
Collapse
Affiliation(s)
- Hedvig Hricak
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Ave, Suite C-278, New York, NY, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Kramer R, Cassola V. Comment on "Hybrid computational phantoms for medical dose reconstruction" by Bolch et al. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2010; 49:499-502. [PMID: 20309705 DOI: 10.1007/s00411-010-0277-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2010] [Accepted: 03/06/2010] [Indexed: 05/29/2023]
|
47
|
Jacob P, Ron E. Late health effects of ionizing radiation: bridging the experimental and epidemiological divide. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2010; 49:109-110. [PMID: 20213137 DOI: 10.1007/s00411-010-0273-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2010] [Accepted: 02/16/2010] [Indexed: 05/28/2023]
|
48
|
Lee C, Lodwick D, Hurtado J, Pafundi D, Williams JL, Bolch WE. The UF family of reference hybrid phantoms for computational radiation dosimetry. Phys Med Biol 2009; 55:339-63. [PMID: 20019401 DOI: 10.1088/0031-9155/55/2/002] [Citation(s) in RCA: 236] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms-those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR. NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros. The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference organ masses from ICRP Publication 89, (3) reference elemental compositions provided in ICRP 89 as well as ICRU Report 46, and (4) reference data on the alimentary tract organs given in ICRP Publications 89 and 100. Various adjustments and refinements to the organ systems of the previously described newborn, 15 year and adult phantoms are also presented. The UF series of hybrid phantoms retain the non-uniform scalability of stylized phantoms while maintaining the anatomical realism of patient-specific voxel phantoms with respect to organ shape, depth and inter-organ distance. While the final versions of these phantoms are in a voxelized format for radiation transport simulation, their primary format is given as NURBS and polygon mesh surfaces, thus permitting one to sculpt non-reference phantoms using the reference phantoms as an anatomic template.
Collapse
Affiliation(s)
- Choonsik Lee
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institute of Health, Bethesda, MD 20852, USA
| | | | | | | | | | | |
Collapse
|