Richter K, Reichel A, Vezočnik V. The role of asymmetric flow field-flow fractionation in drug development - From size separation to advanced characterization. J Chromatogr A 2025; 1739:465542. [PMID: 39613510 DOI: 10.1016/j.chroma.2024.465542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2024] [Revised: 11/15/2024] [Accepted: 11/19/2024] [Indexed: 12/01/2024]
Abstract
Drug development is a complex multi-stage process that aims to deliver therapeutic products to the market. This process employs different analytical methods to separate and characterise compounds, monitor manufacturing, and validate the final drug products to ensure their safety, quality, and efficacy. However, advancements in modern drug development and discovery have led to new types of the therapeutical products of increasing complexity. As such, the capabilities of some traditional analytical techniques have become limited, and the demand for using advanced analytical techniques like field-flow fractionation (FFF) has been increasing. A special feature offered by the FFF family is a unique way of separation based on the analytes' specific physicochemical properties. As such, FFF is a powerful tool for analysing diverse analytes and complex mixtures. Herein, asymmetric flow field-flow fractionation (AF4) is the most frequently used technique within the FFF family in drug development. Therefore, this review aims to provide a general overview of the usage of AF4 technology in the drug development field.
Collapse
Affiliation(s)
- Klaus Richter
- Coriolis Pharma Research GmbH, Fraunhoferstraße 18B, 82152 Martinsried, Germany
| | - Angelika Reichel
- Coriolis Pharma Research GmbH, Fraunhoferstraße 18B, 82152 Martinsried, Germany
| | - Valerija Vezočnik
- Coriolis Pharma Research GmbH, Fraunhoferstraße 18B, 82152 Martinsried, Germany.
| |
Collapse
|
2
|
Wiedmer SK, Riekkola ML. Field-flow fractionation - an excellent tool for fractionation, isolation and/or purification of biomacromolecules. J Chromatogr A 2023; 1712:464492. [PMID: 37944435 DOI: 10.1016/j.chroma.2023.464492] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 10/30/2023] [Accepted: 11/03/2023] [Indexed: 11/12/2023]
Abstract
Field-flow fractionation (FFF) with its several variants, has developed into a mature methodology. The scope of the FFF investigations has expanded, covering both a wide range of basic studies and especially a wide range of analytical applications. Special attention of this review is given to the achievements of FFF with reference to recent applications in the fractionation, isolation, and purification of biomacromolecules, and from which especially those of (in alphabetical order) bacteria, cells, extracellular vesicles, liposomes, lipoproteins, nucleic acids, and viruses and virus-like particles. In evaluating the major approaches and trends demonstrated since 2012, the most significant biomacromolecule applications are compiled in tables. It is also evident that asymmetrical flow field-flow fractionation is by far the most dominant technique in the studies. The industry has also shown current interest in FFF and adopted it in some sophisticated fields. FFF, in combination with appropriate detectors, handles biomacromolecules in open channel in a gentle way due to the lack of shear forces and unwanted interactions caused by the stationary phase present in chromatography. In addition, in isolation and purification of biomacromolecules quite high yields can be achieved under optimal conditions.
Collapse
Affiliation(s)
- Susanne K Wiedmer
- Department of Chemistry, POB 55, 00014 University of Helsinki, Finland
| | | |
Collapse
|
3
|
Guo Y, Ye H, Wang H, Wang Q, Fan S, Dou H. Asymmetrical flow field-flow fractionation combined with ultrafiltration: A novel and high-efficiency approach for separation, purification, and characterization of Ganoderma lucidum polysaccharides. Talanta 2023. [DOI: 10.1016/j.talanta.2022.124053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
4
|
Eskelin K, Oksanen HM. Archaeal Viruses: Production of Virus Particles and Vesicle-like Viruses and Purification Using Asymmetrical Flow Field-Flow Fractionation. Methods Mol Biol 2022; 2522:449-465. [PMID: 36125770 DOI: 10.1007/978-1-0716-2445-6_31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Asymmetrical flow field-flow fractionation (AF4) is a separation method based on hydrodynamic size of the sample components. It can separate a broad size range of components (~103 to 109 Da; particle diameter from ~1 nm to ~1 μm), but is especially well suited for high molecular weight samples such as virus-sized particles and extracellular vesicles. Separation takes place in an open channel where the flows control sample elution. Separation does not involve stationary phase, allowing gentle separation and good recoveries. The method is compatible with a wide variety of buffers. Coupling to various analytical detectors enables rapid assays on the molecular weight and size and their distribution, degradation, and aggregation of the sample components giving information on the sample quality. In addition to being an advanced analytical method, AF4 can be used in a semipreparative mode for purification. Here, we summarize archaeal virus production methods and virus purification by AF4 and provide examples on the steps that need optimization for obtaining good separation with the focus on halophilic archaeal viruses. Importantly, AF4 method is suitable for a variety of viruses and extracellular vesicles regardless of their host organism.
Collapse
Affiliation(s)
- Katri Eskelin
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Helsinki, Finland
| | - Hanna M Oksanen
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Helsinki, Finland.
| |
Collapse
|
5
|
Eskelin K, Oksanen HM, Poranen MM. Sample carryover and cleaning procedures for asymmetrical flow field-flow fractionation instrument. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1181:122920. [PMID: 34536834 DOI: 10.1016/j.jchromb.2021.122920] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 08/23/2021] [Accepted: 08/30/2021] [Indexed: 02/08/2023]
Abstract
Asymmetrical flow field-flow (AF4) fractionation aims in separation of sample components to yield elution of homogenous fractions identified as well-defined peaks in the chromatograms. Separation that occurs in matrix-free open channel potentiates high recovery that can be close to 100%. However, sample properties and separation conditions may induce carryover of sample components during AF4 analysis and in sample sequences. This compromises the quality of the data collected from the online detectors and the downstream offline analytics of the collected fractions. In this study, we followed sample carryover in AF4 using model viruses and analyzed various cleaning solutions and rinse methods to reduce carryover. We introduce an SDS-NaOH -based rinsing and decontamination protocol for the AF4 instrument enabling high-quality data collection.
Collapse
Affiliation(s)
- K Eskelin
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, Viikinkaari 9, University of Helsinki, FI-00014 Helsinki, Finland.
| | - H M Oksanen
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, Viikinkaari 9, University of Helsinki, FI-00014 Helsinki, Finland
| | - M M Poranen
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, Viikinkaari 9, University of Helsinki, FI-00014 Helsinki, Finland
| |
Collapse
|
6
|
Fast and Purification-Free Characterization of Bio-Nanoparticles in Biological Media by Electrical Asymmetrical Flow Field-Flow Fractionation Hyphenated with Multi-Angle Light Scattering and Nanoparticle Tracking Analysis Detection. Molecules 2020; 25:molecules25204703. [PMID: 33066514 PMCID: PMC7587377 DOI: 10.3390/molecules25204703] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 10/08/2020] [Accepted: 10/12/2020] [Indexed: 12/11/2022] Open
Abstract
Accurate physico-chemical characterization of exosomes and liposomes in biological media is challenging due to the inherent complexity of the sample matrix. An appropriate purification step can significantly reduce matrix interferences, and thus facilitate analysis of such demanding samples. Electrical Asymmetrical Flow Field-Flow Fractionation (EAF4) provides online sample purification while simultaneously enabling access to size and Zeta potential of sample constituents in the size range of approx. 1–1000 nm. Hyphenation of EAF4 with Multi-Angle Light Scattering (MALS) and Nanoparticle Tracking Analysis (NTA) detection adds high resolution size and number concentration information turning this setup into a powerful analytical platform for the comprehensive physico-chemical characterization of such challenging samples. We here present EAF4-MALS hyphenated with NTA for the analysis of liposomes and exosomes in complex, biological media. Coupling of the two systems was realized using a flow splitter to deliver the sample at an appropriate flow speed for the NTA measurement. After a proof-of-concept study using polystyrene nanoparticles, the combined setup was successfully applied to analyze liposomes and exosomes spiked into cell culture medium and rabbit serum, respectively. Obtained results highlight the benefits of the EAF4-MALS-NTA platform to study the behavior of these promising drug delivery vesicles under in vivo like conditions.
Collapse
|
7
|
Asymmetrical Flow Field-Flow Fractionation on Virus and Virus-Like Particle Applications. Microorganisms 2019; 7:microorganisms7110555. [PMID: 31726671 PMCID: PMC6921026 DOI: 10.3390/microorganisms7110555] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 10/28/2019] [Accepted: 11/08/2019] [Indexed: 12/16/2022] Open
Abstract
Asymmetrical flow field-flow fractionation (AF4) separates sample components based on their sizes in the absence of a stationary phase. It is well suited for high molecular weight samples such as virus-sized particles. The AF4 experiment can potentially separate molecules within a broad size range (~103−109 Da; particle diameter from 2 nm to 0.5−1 μm). When coupled to light scattering detectors, it enables rapid assays on the size, size distribution, degradation, and aggregation of the studied particle populations. Thus, it can be used to study the quality of purified viruses and virus-like particles. In addition to being an advanced analytical characterization technique, AF4 can be used in a semi-preparative mode. Here, we summarize and provide examples on the steps that need optimization for obtaining good separation with the focus on virus-sized particles.
Collapse
|
8
|
Kondylis P, Schlicksup CJ, Zlotnick A, Jacobson SC. Analytical Techniques to Characterize the Structure, Properties, and Assembly of Virus Capsids. Anal Chem 2019; 91:622-636. [PMID: 30383361 PMCID: PMC6472978 DOI: 10.1021/acs.analchem.8b04824] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Panagiotis Kondylis
- Department of Chemistry, Indiana University, Bloomington, IN 47405-7102, USA
| | - Christopher J. Schlicksup
- Department of Molecular and Cellular Biochemistry, Indiana University, Bloomington, IN 47405-7102, USA
| | - Adam Zlotnick
- Department of Molecular and Cellular Biochemistry, Indiana University, Bloomington, IN 47405-7102, USA
| | - Stephen C. Jacobson
- Department of Chemistry, Indiana University, Bloomington, IN 47405-7102, USA
| |
Collapse
|
9
|
Zhang X, Li Y, Shen S, Lee S, Dou H. Field-flow fractionation: A gentle separation and characterization technique in biomedicine. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.09.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
10
|
Controlled Disassembly and Purification of Functional Viral Subassemblies Using Asymmetrical Flow Field-Flow Fractionation (AF4). Viruses 2018; 10:v10110579. [PMID: 30360510 PMCID: PMC6265779 DOI: 10.3390/v10110579] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Revised: 10/17/2018] [Accepted: 10/19/2018] [Indexed: 02/07/2023] Open
Abstract
Viruses protect their genomes by enclosing them into protein capsids that sometimes contain lipid bilayers that either reside above or below the protein layer. Controlled dissociation of virions provides important information on virion composition, interactions, and stoichiometry of virion components, as well as their possible role in virus life cycles. Dissociation of viruses can be achieved by using various chemicals, enzymatic treatments, and incubation conditions. Asymmetrical flow field-flow fractionation (AF4) is a gentle method where the separation is based on size. Here, we applied AF4 for controlled dissociation of enveloped bacteriophage φ6. Our results indicate that AF4 can be used to assay the efficiency of the dissociation process and to purify functional subviral particles.
Collapse
|
11
|
Lampi M, Oksanen HM, Meier F, Moldenhauer E, Poranen MM, Bamford DH, Eskelin K. Asymmetrical flow field-flow fractionation in purification of an enveloped bacteriophage ϕ6. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1095:251-257. [PMID: 30098552 DOI: 10.1016/j.jchromb.2018.07.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 07/06/2018] [Accepted: 07/09/2018] [Indexed: 02/06/2023]
Abstract
Basic and applied virus research requires specimens that are purified to high homogeneity. Thus, there is much interest in the efficient production and purification of viruses and their subassemblies. Advances in the production steps have shifted the bottle neck of the process to the purification. Nonetheless, the development of purification techniques for different viruses is challenging due to the complex biological nature of the infected cell cultures as well as the biophysical and -chemical differences in the virus particles. We used bacteriophage ϕ6 as a model virus in our attempts to provide a new purification method for enveloped viruses. We compared asymmetrical flow field-flow fractionation (AF4)-based virus purification method to the well-established ultracentrifugation-based purification of ϕ6. In addition, binding of ϕ6 virions to monolithic anion exchange columns was tested to evaluate their applicability in concentrating the AF4 purified specimens. Our results show that AF4 enables one-hour purification of infectious enveloped viruses with specific infectivity of ~1 × 1013 PFU/mg of protein and ~65-95% yields. Obtained purity was comparable with that obtained using ultracentrifugation, but the yields from AF4 purification were 2-3-fold higher. Importantly, high quality virus preparations could be obtained directly from crude cell lysates. Furthermore, when used in combination with in-line light scattering detectors, AF4 purification could be coupled to simultaneous quality control of obtained virus specimen.
Collapse
Affiliation(s)
- Mirka Lampi
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Viikinkaari 9B, FI-00014 Helsinki, Finland
| | - Hanna M Oksanen
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Viikinkaari 9B, FI-00014 Helsinki, Finland
| | - Florian Meier
- Postnova Analytics, Max-Planck-Str. 14, 86899 Landsberg, Germany
| | | | - Minna M Poranen
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Viikinkaari 9B, FI-00014 Helsinki, Finland
| | - Dennis H Bamford
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Viikinkaari 9B, FI-00014 Helsinki, Finland
| | - Katri Eskelin
- Molecular and Integrative Biosciences Research Programme, Faculty of Biological and Environmental Sciences, University of Helsinki, Viikinkaari 9B, FI-00014 Helsinki, Finland.
| |
Collapse
|