• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4597351)   Today's Articles (5551)   Subscriber (49349)
For: Santos-Díaz A, Obruchkov SI, Schulte RF, Noseworthy MD. Phosphorus magnetic resonance spectroscopic imaging using flyback echo planar readout trajectories. MAGMA 2018;31:553-564. [PMID: 29383517 DOI: 10.1007/s10334-018-0675-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 01/09/2018] [Accepted: 01/09/2018] [Indexed: 01/07/2023]
Number Cited by Other Article(s)
1
Bozymski B, Emir U, Dydak U, Shen X, Thomas MA, Özen A, Chiew M, Clarke W, Sawiak S. 3D ultra-short echo time 31P-MRSI with rosette k-space pattern: Feasibility and comparison with conventional weighted CSI. RESEARCH SQUARE 2024:rs.3.rs-4223790. [PMID: 38659806 PMCID: PMC11042414 DOI: 10.21203/rs.3.rs-4223790/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
2
Bogner W, Otazo R, Henning A. Accelerated MR spectroscopic imaging-a review of current and emerging techniques. NMR IN BIOMEDICINE 2021;34:e4314. [PMID: 32399974 PMCID: PMC8244067 DOI: 10.1002/nbm.4314] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 03/24/2020] [Accepted: 03/30/2020] [Indexed: 05/14/2023]
3
Santos-Díaz A, Noseworthy MD. Phosphorus magnetic resonance spectroscopy and imaging (31P-MRS/MRSI) as a window to brain and muscle metabolism: A review of the methods. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.101967] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
4
Rowland BC, Driver ID, Tachrount M, Klomp DWJ, Rivera D, Forner R, Pham A, Italiaander M, Wise RG. Whole brain 31 P MRSI at 7T with a dual-tuned receive array. Magn Reson Med 2020;83:765-775. [PMID: 31441537 PMCID: PMC7614292 DOI: 10.1002/mrm.27953] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 07/23/2019] [Accepted: 07/26/2019] [Indexed: 12/24/2022]
5
Santos-Díaz A, Noseworthy MD. Comparison of compressed sensing reconstruction algorithms for 31P magnetic resonance spectroscopic imaging. Magn Reson Imaging 2019;59:88-96. [PMID: 30853562 DOI: 10.1016/j.mri.2019.03.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Revised: 02/28/2019] [Accepted: 03/04/2019] [Indexed: 02/01/2023]
6
Santos-Díaz A, Harasym D, Noseworthy MD. Dynamic 31 P spectroscopic imaging of skeletal muscles combining flyback echo-planar spectroscopic imaging and compressed sensing. Magn Reson Med 2019;81:3453-3461. [PMID: 30737840 DOI: 10.1002/mrm.27682] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 01/09/2019] [Accepted: 01/10/2019] [Indexed: 01/21/2023]
PrevPage 1 of 1 1Next