1
|
Feng S, Pan C, Ye H, Liu W, Yang W, Lv Y, Tao S. Magnetic Non-Spherical Particles Inducing Vortices in Microchannel for Effective Mixing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2207383. [PMID: 36775909 DOI: 10.1002/smll.202207383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 01/20/2023] [Indexed: 05/11/2023]
Abstract
Mixing in microfluidic channels is dominated by diffusion owing to the absence of chaotic flow. However, high-efficiency microscale mixing over short distances is desired for the development of lab-on-chip systems. Here, enhanced mixing in microchannels achieved using magnetic nonspherical particles (MNSPs), is reported. Benefiting from the nonspherical shape of the MNSPs, secondary vortices exhibiting cyclical characteristics appear in microchannels when the MNSPs rotate under an external magnetic field. Increasing the rotation rate enlarges the secondary vortices, expanding the mixing zone and enhancing the mixing, resulting in a mixing efficiency exceeding 0.9 at Re of 0.069-0.69. Complementary micro-particle image velocimetry (µPIV) for flow field analysis clarifies the mixing mechanism. In addition, a chaotic vortex area is generated in the presence of two MNSPs, which shortens the distance required for achieving an appropriate mixing efficiency. This study demonstrates the potential of employing MNSPs as efficient mixers in lab-on-chip devices.
Collapse
Affiliation(s)
- Shi Feng
- State Key Laboratory of Fine Chemicals, Frontier Science Center for Smart Materials Oriented Chemical Engineering, School of Chemical Engineering, Dalian University of Technology, Dalian, 116024, P. R. China
- Department of Chemistry, School of Chemical Engineering, Dalian University of Technology, Dalian, 116024, P. R. China
| | - Cunliang Pan
- Department of Engineering Mechanics, State Key Laboratory of Structural Analysis for Industrial Equipment, Dalian University of Technology, Dalian, 116024, P. R. China
| | - Hongfei Ye
- Department of Engineering Mechanics, State Key Laboratory of Structural Analysis for Industrial Equipment, Dalian University of Technology, Dalian, 116024, P. R. China
| | - Wendong Liu
- Department of Chemistry, School of Chemical Engineering, Dalian University of Technology, Dalian, 116024, P. R. China
| | - Wenbo Yang
- Department of Chemistry, School of Chemical Engineering, Dalian University of Technology, Dalian, 116024, P. R. China
| | - Yingdi Lv
- Xi'an Modern Chemistry Research Institute, Xi'an, 710065, P. R. China
| | - Shengyang Tao
- State Key Laboratory of Fine Chemicals, Frontier Science Center for Smart Materials Oriented Chemical Engineering, School of Chemical Engineering, Dalian University of Technology, Dalian, 116024, P. R. China
- Department of Chemistry, School of Chemical Engineering, Dalian University of Technology, Dalian, 116024, P. R. China
| |
Collapse
|
2
|
Visuvasam J, Alotaibi H. Analysis of Von Kármán Swirling Flows Due to a Porous Rotating Disk Electrode. MICROMACHINES 2023; 14:582. [PMID: 36984988 PMCID: PMC10056891 DOI: 10.3390/mi14030582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 02/17/2023] [Accepted: 02/18/2023] [Indexed: 06/18/2023]
Abstract
The study of Von Kármán swirling flow is a subject of active interest due to its applications in a wide range of fields, including biofuel manufacturing, rotating heat exchangers, rotating disc reactors, liquid metal pumping engines, food processing, electric power generating systems, designs of multi-pore distributors, and many others. This paper focusses on investigating Von Kármán swirling flows of viscous incompressible fluid due to a rotating disk electrode. The model is based on a system of four coupled second-order non-linear differential equations. The purpose of the present communication is to derive analytical expressions of velocity components by solving the non-linear equations using the homotopy analysis method. Combined effects of the slip λ and porosity γ parameters are studied in detail. If either parameter is increased, all velocity components are reduced, as both have the same effect on the mean velocity profiles. The porosity parameter γ increases the moment coefficient at the disk surface, which monotonically decreases with the slip parameter λ. The analytical results are also compared with numerical solutions, which are in satisfactory agreement. Furthermore, the effects of porosity and slip parameters on velocity profiles are discussed.
Collapse
Affiliation(s)
- James Visuvasam
- Department of Mathematics, Rathnavel Subramaniam College of Arts and Science (Autonomous), Coimbatore 641 402, Tamil Nadu, India
| | - Hammad Alotaibi
- Department of Mathematics and Statistics, Faculty of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
| |
Collapse
|
3
|
Hu X, Gao X, Chen S, Guo J, Zhang Y. DropLab: an automated magnetic digital microfluidic platform for sample-to-answer point-of-care testing-development and application to quantitative immunodiagnostics. MICROSYSTEMS & NANOENGINEERING 2023; 9:10. [PMID: 36644334 PMCID: PMC9833028 DOI: 10.1038/s41378-022-00475-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Revised: 11/24/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
In point-of-care testing (POCT), tests are performed near patients and results are given rapidly for timely clinical decisions. Immunodiagnostic assays are one of the most important analyses for detecting and quantifying protein-based biomarkers. However, existing POCT immunodiagnostics mainly rely on the lateral flow assay (LFA), which has limited sensitivity or quantification capability. Although other immunodiagnostic assays, such as enzyme-linked immunosorbent assays (ELISAs), offer more sensitive and quantitative results, they require complex liquid manipulations that are difficult to implement in POCT settings by conventional means. Here, we show the development of DropLab, an automated sample-in-answer-out POCT immunodiagnostic platform based on magnetic digital microfluidic (MDM) technology. DropLab performs microbead-based ELISA in droplets to offer more sensitive and quantitative testing results. The intricate liquid manipulations required for ELISA are accomplished by controlling droplets with magnetic microbeads using MDM technology, which enables us to achieve full automation and easy operations with DropLab. Four ELISAs (the sample in triplicates and a negative control) can be run in parallel on the thermoformed disposable chip, which greatly improves the throughput and accuracy compared to those of other POCT immunodiagnostic devices. DropLab was validated by measuring two protein targets and one antibody target. The testing results showed that the limit of detection (LOD) of DropLab matched that of the conventional ELISA in a microwell plate. DropLab brings MDM one step closer to being a viable medical technology that is ready for real-world POCT applications.
Collapse
Affiliation(s)
- Xuyang Hu
- China-Singapore International Joint Research Institute, Guangzhou, China
- Guangzhou DropLab Scientific Co. Ltd., Guangzhou, China
| | - Xiangyu Gao
- China-Singapore International Joint Research Institute, Guangzhou, China
| | - Songlin Chen
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
- DropLab Scientific (Singapore) Pvt. Ltd., Singapore, Singapore
| | - Jinhong Guo
- School of Sensing Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yi Zhang
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, China
| |
Collapse
|
4
|
Wang S, Wang H, Cheng Y. Numerical simulation of mixing-induced dynamic interfacial tension inside droplet by lattice Boltzmann method. Chem Eng Sci 2023. [DOI: 10.1016/j.ces.2023.118510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
5
|
Shimizu I, Yamashita K, Tokunaga E. Development of a Simple Fabrication Method for Magnetic Micro Stir Bars and Induction of Rotational Motion in Chlamydomonas reinhardtii. MICROMACHINES 2022; 13:1842. [PMID: 36363863 PMCID: PMC9695637 DOI: 10.3390/mi13111842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/16/2022] [Accepted: 10/25/2022] [Indexed: 06/16/2023]
Abstract
A magnetic micro stirrer bar (MMSB) is used in the mixing operation of microfluidic devices. We have established a low-cost and easy method to make MMSBs using magnetic (neodymium magnets, magnet sheets) or non-magnetic powders (SUS304) as materials. We demonstrated three kinds of MMSB have respective advantages. To confirm the practical use of this MMSB, a cell suspension of the motile unicellular green alga Chlamydomonas reinhardtii was stirred in microwells. As a result, the number of rotating cells increased with only one of the two flagella mechanically removed by the shear force of the rotating bar, which facilitates the kinetic analysis of the flagellar motion of the cell. The rotational motion of the monoflagellate cell was modeled as translational (orbital) + spinning motion of a sphere in a viscous fluid and the driving force per flagellum was confirmed to be consistent with previous literature. Since the present method does not use genetic manipulations or chemicals to remove a flagellum, it is possible to obtain cells in a more naturally viable state quickly and easily than before. However, since the components eluted from the powder material harm the health of cells, it was suggested that MMSB coated with resin for long-term use would be suitable for more diverse applications.
Collapse
|
6
|
Zhang Y, Zhou A, Chen S, Lum GZ, Zhang X. A perspective on magnetic microfluidics: Towards an intelligent future. BIOMICROFLUIDICS 2022; 16:011301. [PMID: 35069962 PMCID: PMC8769766 DOI: 10.1063/5.0079464] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 01/02/2022] [Indexed: 05/09/2023]
Abstract
Magnetic microfluidics has been gradually recognized as an area of its own. Both conventional microfluidic platforms have incorporated magnetic actuation for microfluidic operation and microscale object manipulation. Nonetheless, there is still much room for improvement after decades of development. In this Perspective, we first provide a quick review of existing magnetic microfluidic platforms with a focus on the magnetic tools and actuation mechanisms. Next, we discuss several emerging technologies, including magnetic microrobots, additive manufacture, and artificial intelligence, and their potential application in the future development of magnetic microfluidics. We believe that these technologies can eventually inspire highly functional magnetic tools for microfluidic manipulation and coordinated microfluidic control at the system level, which eventually drives magnetic microfluidics into an intelligent system for automated experimentation.
Collapse
Affiliation(s)
- Yi Zhang
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China Chengdu, China
- Authors to whom correspondence should be addressed:; ;
and
| | - Aiwu Zhou
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
| | - Songlin Chen
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
| | - Guo Zhan Lum
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
- Authors to whom correspondence should be addressed:; ;
and
| | - Xiaosheng Zhang
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China Chengdu, China
- Authors to whom correspondence should be addressed:; ;
and
| |
Collapse
|
7
|
Cheng H, Liu H, Li W, Li M. Recent advances in magnetic digital microfluidic platforms. Electrophoresis 2021; 42:2329-2346. [PMID: 34196022 DOI: 10.1002/elps.202100088] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 06/22/2021] [Accepted: 06/25/2021] [Indexed: 12/14/2022]
Abstract
Magnetic Digital microfluidics (DMF), which enables the manipulation of droplets containing different types of samples and reagents by permanent magnets or electromagnet arrays, has been used as a promising platform technology for bioanalytical and preparative assays. This is due to its unique advantages such as simple and "power free" operation, easy assembly, great compatibility with auto control systems, and dual functionality of magnetic particles (actuation and target attachment). Over the past decades, magnetic DMF technique has gained a widespread attention in many fields such as sample-to-answer molecular diagnostics, immunoassays, cell assays, on-demand chemical synthesis, and single-cell manipulation. In the first part of this review, we summarised features of magnetic DMF. Then, we introduced the actuation mechanisms and fabrication of magnetic DMF. Furthermore, we discussed five main applications of magnetic DMF, namely drug screening, protein assays, polymerase chain reaction (PCR), cell manipulation, and chemical analysis and synthesis. In the last part of the review, current challenges and limitations with magnetic DMF technique were discussed, such as biocompatibility, automation of microdroplet control systems, and microdroplet evaporation, with an eye on towards future development.
Collapse
Affiliation(s)
- Hao Cheng
- Laboratoire de Thermique et Energie de Nantes (LTEN), UMR CNRS 6607, Polytech' Nantes-Université de Nantes, Nantes Cedex 03, France.,School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, Australia
| | - Hangrui Liu
- Department of Physics and Astronomy, Macquarie University, Sydney, New South Wales, Australia
| | - Weihua Li
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, Australia
| | - Ming Li
- School of Engineering, Macquarie University, Sydney, New South Wales, Australia.,Biomolecular Discovery Research Centre, Macquarie University, Sydney, New South Wales, Australia
| |
Collapse
|
8
|
Xu R, Zhao S, Nie L, Deng C, Hao S, Zhao X, Li J, Liu B, Ma J. Study on the Technology of Monodisperse Droplets by a High-Throughput and Instant-Mixing Droplet Microfluidic System. MATERIALS (BASEL, SWITZERLAND) 2021; 14:1263. [PMID: 33799990 PMCID: PMC7962067 DOI: 10.3390/ma14051263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 02/28/2021] [Accepted: 03/02/2021] [Indexed: 11/25/2022]
Abstract
In this study, we report a novel high-throughput and instant-mixing droplet microfluidic system that can prepare uniformly mixed monodisperse droplets at a flow rate of mL/min designed for rapid mixing between multiple solutions and the preparation of micro-/nanoparticles. The system is composed of a magneton micromixer and a T-junction microfluidic device. The magneton micromixer rapidly mixes multiple solutions uniformly through the rotation of the magneton, and the mixed solution is sheared into monodisperse droplets by the silicone oil in the T-junction microfluidic device. The optimal conditions of the preparation of monodisperse droplets for the system have been found and factors affecting droplet size are analyzed for correlation; for example, the structure of the T-junction microfluidic device, the rotation speed of the magneton, etc. At the same time, through the uniformity of the color of the mixed solution, the mixing performance of the system is quantitatively evaluated. Compared with mainstream micromixers on the market, the system has the best mixing performance. Finally, we used the system to simulate the internal gelation broth preparation of zirconium broth and uranium broth. The results show that the system is expected to realize the preparation of ceramic microspheres at room temperature without cooling by the internal gelation process.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Jingtao Ma
- State Key Laboratory of New Ceramics and Fine Processing, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China; (R.X.); (S.Z.); (L.N.); (C.D.); (S.H.); (X.Z.); (J.L.); (B.L.)
| |
Collapse
|
9
|
Chen X, Liu S, Chen Y, Wang S. A review on species mixing in droplets using passive and active micromixers. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY 2021; 101:422-432. [DOI: 10.1080/03067319.2019.1666832] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 09/04/2019] [Indexed: 01/12/2025]
Affiliation(s)
- Xueye Chen
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| | - Shufen Liu
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| | - Yao Chen
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| | - Shouxin Wang
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| |
Collapse
|
10
|
Kanitthamniyom P, Zhou A, Feng S, Liu A, Vasoo S, Zhang Y. A 3D-printed modular magnetic digital microfluidic architecture for on-demand bioanalysis. MICROSYSTEMS & NANOENGINEERING 2020; 6:48. [PMID: 34567660 PMCID: PMC8433373 DOI: 10.1038/s41378-020-0152-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/22/2020] [Accepted: 02/29/2020] [Indexed: 05/04/2023]
Abstract
Magnetic digital microfluidics (MDM) manipulates fluids in the form of droplets on an open substrate, and incorporates surface energy traps (SETs) to facilitate the droplet manipulation. Conventional MDM devices are fabricated monolithically, which makes it difficult to modify the device configuration without completely overhauling the original design. In this paper, we present a modular MDM architecture that enables rapid on-demand configuration and re-configuration of MDM platforms for customized bioanalyses. Each modular component contains a SET and a Lego-like antistud that fits onto a base board with Lego-like studs. We illustrate the versatility of the modular MDM architecture in biomarker sensing, pathogen identification, antibiotic resistance determination, and biochemical quantification by demonstrating immunoassays, phenotypical assays and enzymatic assays on various modular MDM platforms configured on demand to accomplish the fluidic operations required by assorted bioanalytical assays. The modular MDM architecture promises great potential for point-of-care diagnostics by offering on-demand customization of testing platforms for various categories of diagnostic assays. It also provides a new avenue for microfluidic assay development with its high configurability which would significantly reduce the time and cost of the development cycle.
Collapse
Affiliation(s)
- Pojchanun Kanitthamniyom
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
| | - Aiwu Zhou
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
| | - Shilun Feng
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, Singapore
| | - Aiqun Liu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, Singapore
| | - Shawn Vasoo
- National Center for Infectious Disease, Tan Tock Seng Hospital, Singapore, Singapore
| | - Yi Zhang
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
| |
Collapse
|
11
|
Liu H, Zheng S, Yang X, Liao W, Wang C, Miao W, Tang J, Wang D, Tian Y. Magnetic Actuation Multifunctional Platform Combining Microdroplets Delivery and Stirring. ACS APPLIED MATERIALS & INTERFACES 2019; 11:47642-47648. [PMID: 31765117 DOI: 10.1021/acsami.9b18957] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Multifunctional droplets manipulation devices are in urgent need for various laboratory operations such as chemical reaction and biological analysis. However, most current techniques that achieved a controllable droplet transport system mainly rely on passive diffusion for mixing, limiting their practical applications. Here, we develop a magnetic controlled dimple on slippery surface (MCDSS) that enables arbitrary direction or even uphill droplet transport through the synergy between gravitational force and asymmetrical droplet deformation. Further experiments demonstrate that our system could also be used for stirring microdroplets and accelerating the mixing speed by more than one hundred times. In addition, the microstir strategy could help to avoid locally uneven production of precipitation or gas in heterogeneous reactions. This combination of droplet delivery and agitation may have a promising future for application in various fields, for example, laboratory-on-a-chip platforms and microengines.
Collapse
Affiliation(s)
- He Liu
- Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, School of Chemistry , Beihang University , Beijing 100191 , P. R. China
| | - Shuang Zheng
- Beijing National Laboratory for Molecular Sciences (BNLMS), Key Laboratory of Green Printing , Institute of Chemistry, Chinese Academy of Sciences , Beijing 100190 , P. R. China
| | - Xuan Yang
- Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, School of Chemistry , Beihang University , Beijing 100191 , P. R. China
| | - Wenbo Liao
- Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, School of Chemistry , Beihang University , Beijing 100191 , P. R. China
| | - Can Wang
- Key Laboratory of Bio-inspired Materials and Interfacial Science , Technical Institute of Physics and Chemistry, Chinese Academy of Sciences , Beijing 100190 , P. R. China
| | - Weining Miao
- Key Laboratory of Bio-inspired Materials and Interfacial Science , Technical Institute of Physics and Chemistry, Chinese Academy of Sciences , Beijing 100190 , P. R. China
| | - Jiayue Tang
- Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, School of Chemistry , Beihang University , Beijing 100191 , P. R. China
| | - Dianyu Wang
- Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, School of Chemistry , Beihang University , Beijing 100191 , P. R. China
| | - Ye Tian
- Key Laboratory of Bio-inspired Materials and Interfacial Science , Technical Institute of Physics and Chemistry, Chinese Academy of Sciences , Beijing 100190 , P. R. China
| |
Collapse
|
12
|
Abstract
A digital microfluidic platform manipulates droplets on an open surface. Magnetic digital microfluidics utilizes magnetic forces for actuation and offers unique advantages compared to other digital microfluidic platforms. First, the magnetic particles used in magnetic digital microfluidics have multiple functions. In addition to serving as actuators, they also provide a functional solid substrate for molecule binding, which enables a wide range of applications in molecular diagnostics and immunodiagnostics. Second, magnetic digital microfluidics can be manually operated in a "power-free" manner, which allows for operation in low-resource environments for point-of-care diagnostics where even batteries are considered a luxury item. This review covers research areas related to magnetic digital microfluidics. This paper first summarizes the current development of magnetic digital microfluidics. Various methods of droplet manipulation using magnetic forces are discussed, ranging from conventional magnetic particle-based actuation to the recent development of ferrofluids and magnetic liquid marbles. This paper also discusses several new approaches that use magnetically controlled flexible substrates for droplet manipulation. In addition, we emphasize applications of magnetic digital microfluidics in biosensing and medical diagnostics, and identify the current limitations of magnetic digital microfluidics. We provide a perspective on possible solutions to close these gaps. Finally, the paper discusses the future improvement of magnetic digital microfluidics to explore potential new research directions.
Collapse
Affiliation(s)
- Yi Zhang
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore.
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane, QLD 4111, Australia
| |
Collapse
|
13
|
Nama N, Huang PH, Huang TJ, Costanzo F. Investigation of micromixing by acoustically oscillated sharp-edges. BIOMICROFLUIDICS 2016; 10:024124. [PMID: 27158292 PMCID: PMC4833753 DOI: 10.1063/1.4946875] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Accepted: 04/04/2016] [Indexed: 05/03/2023]
Abstract
Recently, acoustically oscillated sharp-edges have been utilized to achieve rapid and homogeneous mixing in microchannels. Here, we present a numerical model to investigate acoustic mixing inside a sharp-edge-based micromixer in the presence of a background flow. We extend our previously reported numerical model to include the mixing phenomena by using perturbation analysis and the Generalized Lagrangian Mean (GLM) theory in conjunction with the convection-diffusion equation. We divide the flow variables into zeroth-order, first-order, and second-order variables. This results in three sets of equations representing the background flow, acoustic response, and the time-averaged streaming flow, respectively. These equations are then solved successively to obtain the mean Lagrangian velocity which is combined with the convection-diffusion equation to predict the concentration profile. We validate our numerical model via a comparison of the numerical results with the experimentally obtained values of the mixing index for different flow rates. Further, we employ our model to study the effect of the applied input power and the background flow on the mixing performance of the sharp-edge-based micromixer. We also suggest potential design changes to the previously reported sharp-edge-based micromixer to improve its performance. Finally, we investigate the generation of a tunable concentration gradient by a linear arrangement of the sharp-edge structures inside the microchannel.
Collapse
Affiliation(s)
- Nitesh Nama
- Department of Engineering Science and Mechanics, The Pennsylvania State University , University Park, Pennsylvania 16802, USA
| | - Po-Hsun Huang
- Department of Engineering Science and Mechanics, The Pennsylvania State University , University Park, Pennsylvania 16802, USA
| | | | | |
Collapse
|
14
|
Shirasawa H, Kumagai J, Sato E, Kabashima K, Kumazawa Y, Sato W, Miura H, Nakamura R, Nanjo H, Minamiya Y, Akagami Y, Terada Y. Novel method for immunofluorescence staining of mammalian eggs using non-contact alternating-current electric-field mixing of microdroplets. Sci Rep 2015; 5:15371. [PMID: 26477850 PMCID: PMC4609987 DOI: 10.1038/srep15371] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Accepted: 09/24/2015] [Indexed: 02/06/2023] Open
Abstract
Recently, a new technique was developed for non-catalytically mixing microdroplets. In this method, an alternating-current (AC) electric field is used to promote the antigen–antibody reaction within the microdroplet. Previously, this technique has only been applied to histological examinations of flat structures, such as surgical specimens. In this study, we applied this technique for the first time to immunofluorescence staining of three-dimensional structures, specifically, mammalian eggs. We diluted an antibody against microtubules from 1:1,000 to 1:16,000, and compared the chromatic degree and extent of fading across dilutions. In addition, we varied the frequency of AC electric-field mixing from 5 Hz to 46 Hz and evaluated the effect on microtubule staining. Microtubules were more strongly stained after AC electric-field mixing for only 5 minutes, even when the concentration of primary antibody was 10 times lower than in conventional methods. AC electric-field mixing also alleviated microtubule fading. At all frequencies tested, AC electric-field mixing resulted in stronger microtubule staining than in controls. There was no clear difference in a microtubule staining between frequencies. These results suggest that the novel method could reduce antibody consumption and shorten immunofluorescence staining time.
Collapse
Affiliation(s)
- Hiromitsu Shirasawa
- Department of Obstetrics and Gynecology, Akita University Graduate School of Medicine, Akita, Japan
| | - Jin Kumagai
- Department of Obstetrics and Gynecology, Akita University Graduate School of Medicine, Akita, Japan
| | - Emiko Sato
- Department of Obstetrics and Gynecology, Akita University Graduate School of Medicine, Akita, Japan
| | - Katsuya Kabashima
- Department of Obstetrics and Gynecology, Akita University Graduate School of Medicine, Akita, Japan
| | - Yukiyo Kumazawa
- Department of Obstetrics and Gynecology, Akita University Graduate School of Medicine, Akita, Japan
| | - Wataru Sato
- Department of Obstetrics and Gynecology, Akita University Graduate School of Medicine, Akita, Japan
| | - Hiroshi Miura
- Department of Obstetrics and Gynecology, Akita University Graduate School of Medicine, Akita, Japan
| | | | - Hiroshi Nanjo
- Division of Clinical Pathology, Akita University Graduate School of Medicine, Akita, Japan
| | - Yoshihiro Minamiya
- Department of Thoracic Surgery, Akita University Graduate School of Medicine, Akita, Japan
| | | | - Yukihiro Terada
- Department of Obstetrics and Gynecology, Akita University Graduate School of Medicine, Akita, Japan
| |
Collapse
|
15
|
Shin DJ, Wang TH. Magnetic droplet manipulation platforms for nucleic acid detection at the point of care. Ann Biomed Eng 2014; 42:2289-302. [PMID: 25008142 DOI: 10.1007/s10439-014-1060-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Accepted: 06/19/2014] [Indexed: 12/13/2022]
Abstract
This review summarizes recent developments in the use of magnetically actuated droplets in point-of-care molecular diagnostic platforms. We discuss the fundamentals of magnetic droplet manipulation and the various modes of actuation. The balance of forces acting on a droplet during transport and particle extraction, as well as the devices and instrumentation developed to perform these operations will be presented and discussed. Furthermore, we review some of the recent advances on the diagnostic applications of platforms utilizing magnetic manipulation for genetic assessment of biological samples.
Collapse
Affiliation(s)
- Dong Jin Shin
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | | |
Collapse
|
16
|
Chong WH, Chin LK, Tan RLS, Wang H, Liu AQ, Chen H. Stirring in Suspension: Nanometer-Sized Magnetic Stir Bars. Angew Chem Int Ed Engl 2013; 52:8570-3. [DOI: 10.1002/anie.201303249] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2013] [Indexed: 01/08/2023]
|
17
|
Chong WH, Chin LK, Tan RLS, Wang H, Liu AQ, Chen H. Stirring in Suspension: Nanometer-Sized Magnetic Stir Bars. Angew Chem Int Ed Engl 2013. [DOI: 10.1002/ange.201303249] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|