1
|
Seibold M, Sigrist B, Götschi T, Widmer J, Hodel S, Farshad M, Navab N, Fürnstahl P, Laux CJ. A new sensing paradigm for the vibroacoustic detection of pedicle screw loosening. Med Biol Eng Comput 2025; 63:1001-1011. [PMID: 39560918 PMCID: PMC11946995 DOI: 10.1007/s11517-024-03235-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 10/27/2024] [Indexed: 11/20/2024]
Abstract
The current clinical gold standard to assess the condition and detect loosening of pedicle screw implants is radiation-emitting medical imaging. However, solely based on medical imaging, clinicians are not able to reliably identify loose implants in a substantial amount of cases. To complement medical imaging for pedicle screw loosening detection, we propose a new methodology and paradigm for the radiation-free, non-destructive, and easy-to-integrate loosening detection based on vibroacoustic sensing. For the detection of a loose implant, we excite the vertebra of interest with a sine sweep vibration at the spinous process and use a custom highly sensitive piezo vibration sensor attached directly at the screw head to capture the propagated vibration characteristics which are analyzed using a detection pipeline based on spectrogram features and a SE-ResNet-18. To validate the proposed approach, we propose a novel, biomechanically validated simulation technique for pedicle screw loosening, conduct experiments using four human cadaveric lumbar spine specimens, and evaluate our algorithm in a cross-validation experiment. The proposed method reaches a sensitivity of 91.50 ± 6.58 % and a specificity of 91.10 ± 2.27 % for pedicle screw loosening detection.
Collapse
Affiliation(s)
- Matthias Seibold
- Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, Zürich, Switzerland.
- Computer Aided Medical Procedures, Technical University Munich, Munich, Germany.
| | - Bastian Sigrist
- Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
| | - Tobias Götschi
- Spine Biomechanics, Balgrist University Hospital, ETH Zurich, Zürich, Switzerland
| | - Jonas Widmer
- Spine Biomechanics, Balgrist University Hospital, ETH Zurich, Zürich, Switzerland
| | - Sandro Hodel
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
| | - Mazda Farshad
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
| | - Nassir Navab
- Computer Aided Medical Procedures, Technical University Munich, Munich, Germany
| | - Philipp Fürnstahl
- Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
| | - Christoph J Laux
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
| |
Collapse
|
2
|
Lu X, Zhao Y, Peng X, Lu C, Wu Z, Xu H, Qin Y, Xu Y, Wang Q, Hao Y, Geng D. Comprehensive Overview of Interface Strategies in Implant Osseointegration. ADVANCED FUNCTIONAL MATERIALS 2024. [DOI: 10.1002/adfm.202418849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2024] [Indexed: 01/05/2025]
Abstract
AbstractWith the improvement of implant design and the expansion of application scenarios, orthopedic implants have become a common surgical option for treating fractures and end‐stage osteoarthritis. Their common goal is rapidly forming and long‐term stable osseointegration. However, this fixation effect is limited by implant surface characteristics and peri‐implant bone tissue activity. Therefore, this review summarizes the strategies of interface engineering (osteogenic peptides, growth factors, and metal ions) and treatment methods (porous nanotubes, hydrogel embedding, and other load‐release systems) through research on its biological mechanism, paving the way to achieve the adaptation of both and coordination between different strategies. With the transition of the osseointegration stage, interface engineering strategies have demonstrated varying therapeutic effects. Especially, the activity of osteoblasts runs almost through the entire process of osseointegration, and their physiological activities play a dominant role in bone formation. Furthermore, diseases impacting bone metabolism exacerbate the difficulty of achieving osseointegration. This review aims to assist future research on osseointegration engineering strategies to improve implant‐bone fixation, promote fracture healing, and enhance post‐implantation recovery.
Collapse
Affiliation(s)
- Xiaoheng Lu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Yuhu Zhao
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Xiaole Peng
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
- Department of Orthopedics The First Affiliated Hospital of Chongqing Medical University 1 Youyi Street Chongqing 400016 China
| | - Chengyao Lu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Zebin Wu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Hao Xu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Yi Qin
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Yaozeng Xu
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Qing Wang
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| | - Yuefeng Hao
- Orthopedics and Sports Medicine Center The Affiliated Suzhou Hospital of Nanjing Medical University 242 Guangji Street Suzhou Jiangsu 215006 China
| | - Dechun Geng
- Department of Orthopedics The First Affiliated Hospital of Soochow University 188 Shizi Street Suzhou Jiangsu 215006 China
| |
Collapse
|
3
|
Zhou Q, Rose LRF, Ebeling P, Russ M, Fitzgerald M, Chiu WK. Harmonic Vibration Analysis in a Simplified Model for Monitoring Transfemoral Implant Loosening. SENSORS (BASEL, SWITZERLAND) 2024; 24:6453. [PMID: 39409493 PMCID: PMC11479371 DOI: 10.3390/s24196453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Revised: 09/27/2024] [Accepted: 10/05/2024] [Indexed: 10/20/2024]
Abstract
A simplified axisymmetric model of a transfemoral osseointegration implant was used to investigate the influence of the contact condition at the bone-implant interface on the vibrational response. The experimental setup allowed the degree of implant tightness to be controlled using a circumferential compression device affixed to the bone. Diametrically placed sensors allowed torsional modes to be distinguished from flexural modes. The results showed that the structural resonant frequencies did not shift significantly with tightness levels. The first torsional mode of vibration was found to be particularly sensitive to interface loosening. Harmonics in the vibrational response became prominent when the amplitude of the applied torque increased beyond a critical level. The torque level at which the third harmonic begins to rise correlated with implant criticality, suggesting a potential strategy for early detection of implant loosening based on monitoring the amplitude of the third harmonic of the torsional mode.
Collapse
Affiliation(s)
- Qingsong Zhou
- Department of Mechanical & Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia (W.K.C.)
| | - Louis Raymond Francis Rose
- Department of Mechanical & Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia (W.K.C.)
| | - Peter Ebeling
- Department of Medicine, School of Clinical Sciences, Monash University, Clayton, VIC 3800, Australia;
| | - Matthias Russ
- The Alfred Hospital, Melbourne, VIC 3004, Australia (M.F.)
- National Trauma Research Institute, Melbourne, VIC 3004, Australia
| | - Mark Fitzgerald
- The Alfred Hospital, Melbourne, VIC 3004, Australia (M.F.)
- National Trauma Research Institute, Melbourne, VIC 3004, Australia
| | - Wing Kong Chiu
- Department of Mechanical & Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia (W.K.C.)
| |
Collapse
|
4
|
Schumacher N, Geiger F, Spors S, Bader R, Haubelt C, Kluess D. Detection of Total Hip Replacement Loosening Based on Structure-Borne Sound: Influence of the Position of the Sensor on the Hip Stem. SENSORS (BASEL, SWITZERLAND) 2024; 24:4594. [PMID: 39065992 PMCID: PMC11280482 DOI: 10.3390/s24144594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/11/2024] [Accepted: 07/12/2024] [Indexed: 07/28/2024]
Abstract
Accurate detection of implant loosening is crucial for early intervention in total hip replacements, but current imaging methods lack sensitivity and specificity. Vibration methods, already successful in dentistry, represent a promising approach. In order to detect loosening of the total hip replacement, excitation and measurement should be performed intracorporeally to minimize the influence of soft tissue on damping of the signals. However, only implants with a single sensor intracorporeally integrated into the implant for detecting vibrations have been presented in the literature. Considering different mode shapes, the sensor's position on the implant is assumed to influence the signals. In the work at hand, the influence of the position of the sensor on the recording of the vibrations on the implant was investigated. For this purpose, a simplified test setup was created with a titanium rod implanted in a cylinder of artificial cancellous bone. Mechanical stimulation via an exciter attached to the rod was recorded by three accelerometers at varying positions along the titanium rod. Three states of peri-implant loosening within the bone stock were simulated by extracting the bone material around the titanium rod, and different markers were analyzed to distinguish between these states of loosening. In addition, a modal analysis was performed using the finite element method to analyze the mode shapes. Distinct differences in the signals recorded by the acceleration sensors within defects highlight the influence of sensor position on mode detection and natural frequencies. Thus, using multiple sensors could be advantageous in accurately detecting all modes and determining the implant loosening state more precisely.
Collapse
Affiliation(s)
- Nico Schumacher
- Applied Microelectronics and Computer Engineering, University of Rostock, 18059 Rostock, Germany;
| | - Franziska Geiger
- Department of Orthopaedics, Rostock University Medical Center, 18057 Rostock, Germany; (R.B.); (D.K.)
| | - Sascha Spors
- Institute of Communications Engineering, University of Rostock, 18059 Rostock, Germany;
| | - Rainer Bader
- Department of Orthopaedics, Rostock University Medical Center, 18057 Rostock, Germany; (R.B.); (D.K.)
| | - Christian Haubelt
- Applied Microelectronics and Computer Engineering, University of Rostock, 18059 Rostock, Germany;
| | - Daniel Kluess
- Department of Orthopaedics, Rostock University Medical Center, 18057 Rostock, Germany; (R.B.); (D.K.)
| |
Collapse
|
5
|
Hall TAG, Cegla F, van Arkel RJ. Passive Biotelemetric Detection of Tibial Debonding in Wireless Battery-Free Smart Knee Implants. SENSORS (BASEL, SWITZERLAND) 2024; 24:1696. [PMID: 38475232 DOI: 10.3390/s24051696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 02/23/2024] [Accepted: 02/25/2024] [Indexed: 03/14/2024]
Abstract
Aseptic loosening is the dominant failure mechanism in contemporary knee replacement surgery, but diagnostic techniques are poorly sensitive to the early stages of loosening and poorly specific in delineating aseptic cases from infections. Smart implants have been proposed as a solution, but incorporating components for sensing, powering, processing, and communication increases device cost, size, and risk; hence, minimising onboard instrumentation is desirable. In this study, two wireless, battery-free smart implants were developed that used passive biotelemetry to measure fixation at the implant-cement interface of the tibial components. The sensing system comprised of a piezoelectric transducer and coil, with the transducer affixed to the superior surface of the tibial trays of both partial (PKR) and total knee replacement (TKR) systems. Fixation was measured via pulse-echo responses elicited via a three-coil inductive link. The instrumented systems could detect loss of fixation when the implants were partially debonded (+7.1% PKA, +32.6% TKA, both p < 0.001) and fully debonded in situ (+6.3% PKA, +32.5% TKA, both p < 0.001). Measurements were robust to variations in positioning of the external reader, soft tissue, and the femoral component. With low cost and small form factor, the smart implant concept could be adopted for clinical use, particularly for generating an understanding of uncertain aseptic loosening mechanisms.
Collapse
Affiliation(s)
- Thomas A G Hall
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
| | - Frederic Cegla
- Non-Destructive Evaluation Group, Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
| | - Richard J van Arkel
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
| |
Collapse
|
6
|
Lützelberger J, Arneth P, Franck A, Drese KS. Ultrasonic Interferometric Procedure for Quantifying the Bone-Implant Interface. SENSORS (BASEL, SWITZERLAND) 2023; 23:5942. [PMID: 37447790 DOI: 10.3390/s23135942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 06/19/2023] [Accepted: 06/22/2023] [Indexed: 07/15/2023]
Abstract
The loosening of an artificial joint is a frequent and critical complication in orthopedics and trauma surgery. Due to a lack of accuracy, conventional diagnostic methods such as projection radiography cannot reliably diagnose loosening in its early stages or detect whether it is associated with the formation of a biofilm at the bone-implant interface. In this work, we present a non-invasive ultrasound-based interferometric measurement procedure for quantifying the thickness of the layer between bone and prosthesis as a correlate to loosening. In principle, it also allows for the material characterization of the interface. A well-known analytical model for the superposition of sound waves reflected in a three-layer system was combined with a new method in data processing to be suitable for medical application at the bone-implant interface. By non-linear fitting of the theoretical prediction of the model to the actual shape of the reflected sound waves in the frequency domain, the thickness of the interlayer can be determined and predictions about its physical properties are possible. With respect to determining the layer's thickness, the presented approach was successfully applied to idealized test systems and a bone-implant system in the range of approx. 200 µm to 2 mm. After further optimization and adaptation, as well as further experimental tests, the procedure offers great potential to significantly improve the diagnosis of prosthesis loosening at an early stage and may also be applicable to detecting the formation of a biofilm.
Collapse
Affiliation(s)
- Jan Lützelberger
- Institute of Sensor and Actuator Technology (ISAT), Coburg University of Applied Sciences and Arts, Am Hofbräuhaus 1b, 96450 Coburg, Germany
| | - Philipp Arneth
- Institute of Sensor and Actuator Technology (ISAT), Coburg University of Applied Sciences and Arts, Am Hofbräuhaus 1b, 96450 Coburg, Germany
| | - Alexander Franck
- Department of Trauma Surgery and Orthopedics, REGIOMED Clinical Center Coburg, Ketschendorfer Str. 33, 96450 Coburg, Germany
- School of Medicine, University of Split, 21000 Split, Croatia
| | - Klaus Stefan Drese
- Institute of Sensor and Actuator Technology (ISAT), Coburg University of Applied Sciences and Arts, Am Hofbräuhaus 1b, 96450 Coburg, Germany
| |
Collapse
|
7
|
Veletić M, Apu EH, Simić M, Bergsland J, Balasingham I, Contag CH, Ashammakhi N. Implants with Sensing Capabilities. Chem Rev 2022; 122:16329-16363. [PMID: 35981266 DOI: 10.1021/acs.chemrev.2c00005] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Because of the aging human population and increased numbers of surgical procedures being performed, there is a growing number of biomedical devices being implanted each year. Although the benefits of implants are significant, there are risks to having foreign materials in the body that may lead to complications that may remain undetectable until a time at which the damage done becomes irreversible. To address this challenge, advances in implantable sensors may enable early detection of even minor changes in the implants or the surrounding tissues and provide early cues for intervention. Therefore, integrating sensors with implants will enable real-time monitoring and lead to improvements in implant function. Sensor integration has been mostly applied to cardiovascular, neural, and orthopedic implants, and advances in combined implant-sensor devices have been significant, yet there are needs still to be addressed. Sensor-integrating implants are still in their infancy; however, some have already made it to the clinic. With an interdisciplinary approach, these sensor-integrating devices will become more efficient, providing clear paths to clinical translation in the future.
Collapse
Affiliation(s)
- Mladen Veletić
- Department of Electronic Systems, Norwegian University of Science and Technology, 7491 Trondheim, Norway.,The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Ehsanul Hoque Apu
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States.,Division of Hematology and Oncology, Department of Internal Medicine, Michigan Medicine, University of Michigan, Ann Arbor, Michigan 48105, United States
| | - Mitar Simić
- Faculty of Electrical Engineering, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
| | - Jacob Bergsland
- The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Ilangko Balasingham
- Department of Electronic Systems, Norwegian University of Science and Technology, 7491 Trondheim, Norway.,The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Christopher H Contag
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States
| | - Nureddin Ashammakhi
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States.,Department of Bioengineering, University of California, Los Angeles, California 90095, United States
| |
Collapse
|
8
|
García-Aznar JM, Nasello G, Hervas-Raluy S, Pérez MÁ, Gómez-Benito MJ. Multiscale modeling of bone tissue mechanobiology. Bone 2021; 151:116032. [PMID: 34118446 DOI: 10.1016/j.bone.2021.116032] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 04/25/2021] [Accepted: 06/02/2021] [Indexed: 02/07/2023]
Abstract
Mechanical environment has a crucial role in our organism at the different levels, ranging from cells to tissues and our own organs. This regulatory role is especially relevant for bones, given their importance as load-transmitting elements that allow the movement of our body as well as the protection of vital organs from load impacts. Therefore bone, as living tissue, is continuously adapting its properties, shape and repairing itself, being the mechanical loads one of the main regulatory stimuli that modulate this adaptive behavior. Here we review some key results of bone mechanobiology from computational models, describing the effect that changes associated to the mechanical environment induce in bone response, implant design and scaffold-driven bone regeneration.
Collapse
Affiliation(s)
- José Manuel García-Aznar
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Instituto de Investigación Sanitaria Aragón (IIS Aragón), University of Zaragoza, Zaragoza, Spain.
| | - Gabriele Nasello
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Instituto de Investigación Sanitaria Aragón (IIS Aragón), University of Zaragoza, Zaragoza, Spain; Biomechanics Section, KU Leuven, Leuven, Belgium
| | - Silvia Hervas-Raluy
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Instituto de Investigación Sanitaria Aragón (IIS Aragón), University of Zaragoza, Zaragoza, Spain
| | - María Ángeles Pérez
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Instituto de Investigación Sanitaria Aragón (IIS Aragón), University of Zaragoza, Zaragoza, Spain
| | - María José Gómez-Benito
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigación en Ingeniería de Aragón (I3A), Instituto de Investigación Sanitaria Aragón (IIS Aragón), University of Zaragoza, Zaragoza, Spain
| |
Collapse
|
9
|
Safaei M, Bolus NB, Whittingslow DC, Jeong HK, Erturk A, Inan OT. Vibration Stimulation as a Non-Invasive Approach to Monitor the Severity of Meniscus Tears. IEEE Trans Neural Syst Rehabil Eng 2021; 29:350-359. [PMID: 33428572 DOI: 10.1109/tnsre.2021.3050439] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Musculoskeletal disorders and injuries are one of the most prevalent medical conditions across age groups. Due to a high load-bearing function, the knee is particularly susceptible to injuries such as meniscus tears. Imaging techniques are commonly used to assess meniscus injuries, though this approach suffers from limitations including high cost, need for skilled personnel, and confinement to laboratory or clinical settings. Vibration-based structural monitoring methods in the form of acoustic emission analysis and vibration stimulation have the potential to address the limits associated with current diagnostic technologies. In this study, an active vibration measurement technique is employed to investigate the presence and severity of meniscus tear in cadaver limbs. In a highly controlled ex vivo experimental design, a series of cadaver knees (n =6) were evaluated under an external vibration, and the frequency response of the joint was analyzed to differentiate the intact and affected samples. Four stages of knee integrity were considered: baseline, sham surgery, meniscus tear, and meniscectomy. Analyzing the frequency response of injured legs showed significant changes compared to the baseline and sham stages at selected frequency bandwidths. Furthermore, a qualitative analytical model of the knee was developed based on the Euler-Bernoulli beam theory representing the meniscus tear as a change in the local stiffness of the system. Similar trends in frequency response modulation were observed in the experimental results and analytical model. These findings serve as a foundation for further development of wearable devices for detection and grading of meniscus tear and for improving our understanding of the physiological effects of injuries on the vibration characteristics of the knee. Such systems can also aid in quantifying rehabilitation progress following reconstructive surgery and / or during physical therapy.
Collapse
|
10
|
Hall TAG, Cegla F, van Arkel RJ. Simple Smart Implants: Simultaneous Monitoring of Loosening and Temperature in Orthopaedics With an Embedded Ultrasound Transducer. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:102-110. [PMID: 33471767 DOI: 10.1109/tbcas.2021.3052970] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Implant failure can have devastating consequences on patient outcomes following joint replacement. Time to diagnosis affects subsequent treatment success, but current diagnostics do not give early warning and lack accuracy. This research proposes an embedded ultrasound system to monitor implant fixation and temperature - a potential indicator of infection. Requiring only two implanted components: a piezoelectric transducer and a coil, pulse-echo responses are elicited via a three-coil inductive link. This passive system avoids the need for batteries, energy harvesters, and microprocessors, resulting in minimal changes to existing implant architecture. Proof-of-concept was demonstrated in vitro for a titanium plate cemented into synthetic bone, using a small embedded coil with 10 mm diameter. Gross loosening - simulated by completely debonding the implant-cement interface - was detectable with 95% confidence at up to 12 mm implantation depth. Temperature was calibrated with root mean square error of 0.19°C at 5 mm, with measurements accurate to ±1°C with 95% confidence up to 6 mm implantation depth. These data demonstrate that with only a transducer and coil implanted, it is possible to measure fixation and temperature simultaneously. This simple smart implant approach minimises the need to modify well-established implant designs, and hence could enable mass-market adoption.
Collapse
|
11
|
Vogl F, Greger S, Favre P, Taylor WR, Thistlethwaite P. Differentiation between mechanically loose and fixed press-fit implants using quantitative acoustics and load self-referencing: A phantom study on shoulder prostheses in polyurethane foam. PLoS One 2020; 15:e0233548. [PMID: 32469919 PMCID: PMC7259646 DOI: 10.1371/journal.pone.0233548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Accepted: 05/07/2020] [Indexed: 11/19/2022] Open
Abstract
This study proposes to use cross-interface quantitative acoustics (ci-qA) and load self-referencing (LSR) to assess implant stability in a radiation-free, inexpensive, rapid, and quantitative manner. Eight bone analog specimens, made from polyurethane foam, were implanted with a cementless stemless shoulder implant—first in a fixed and later in a loose configuration—and measured using ci-qA under two load conditions. The loose implants exhibited higher micromotion and lower pull-out strength than their stable counterparts, with all values falling within the range of reported reference values. All acoustic characteristics differentiated between loose and fixed implants (maximum area-under-curve AUC = 1.0 for mean total signal energy, AUC = 1.0 for mean total signal energy ratio, AUC = 0.8 for harmonic ratio, and AUC = 0.92 for load self-referencing coefficient). While these results on bone substitute material will need to be confirmed on real bone specimen, ci-qA could ultimately facilitate the assessment of primary stability during implantation surgery and avoid unnecessary revision through quantitative evaluation of secondary stability during follow-up.
Collapse
Affiliation(s)
- Florian Vogl
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- * E-mail:
| | | | | | | | | |
Collapse
|
12
|
Yousefsani SA, Dejnabadi H, Guyen O, Aminian K. A Vibrational Technique for In Vitro Intraoperative Prosthesis Fixation Monitoring. IEEE Trans Biomed Eng 2020; 67:2953-2964. [PMID: 32091985 DOI: 10.1109/tbme.2020.2974380] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE In this paper, a new vibrational modal analysis technique was developed for intraoperative cementless prosthesis fixation evaluation upon hammering. METHODS An artificial bone (Sawbones)-prosthesis system was excited by sweeping of a sine signal over a wide frequency range. The exponential sine sweep technique was implemented to the response signal in order to determine the linear impulse response. Recursive Fourier transform enhancement (RFTE) technique was applied to the linear impulse response signal in order to enhance the frequency spectrum with sharp and distinguishable peak values indicating distinct high natural frequencies of the system (ranging from 15 kHz to 90 kHz). The experiment was repeated with 5 Sawbones-prosthesis samples. Upon successive hammering during the prosthesis insertion, variation of each natural frequency was traced. RESULTS Compared to classical Fast Fourier Transform, RFTE provided a better tracing and enhancement of frequency components during insertion. Three different types of frequency evolving trends (monotonically increasing, insensitive, and plateau-like) were observed for all samples, as confirmed by a new finite element simulation of the prosthesis dynamic insertion. Two main mechanical phenomena (i.e., geometrical compaction and compressive stress) were shown to govern these trends in opposite ways. Follow-up of the plateau-like trend upon hammering showed that the frequency shift is a good indicator of fixation. CONCLUSION Alongside the individual follow-up of frequency shifts, combinatorial frequency analysis provides new objective information on the mechanical stability of Sawbone-prosthesis fixation. SIGNIFICANCE The proposed vibrational technique based on RTFE can provide the surgeon with a new assistive diagnostic technique during the surgery by indicating when the bone-prosthesis fixation is acceptable, and beyond of which further hammering should be done cautiously to avoid bone fracture.
Collapse
|
13
|
Cachão JH, Soares dos Santos MP, Bernardo R, Ramos A, Bader R, Ferreira JAF, Torres Marques A, Simões JAO. Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants. SENSORS 2019; 20:s20010104. [PMID: 31878028 PMCID: PMC6982938 DOI: 10.3390/s20010104] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 11/07/2019] [Accepted: 11/10/2019] [Indexed: 02/02/2023]
Abstract
Musculoskeletal disorders are becoming an ever-growing societal burden and, as a result, millions of bone replacements surgeries are performed per year worldwide. Despite total joint replacements being recognized among the most successful surgeries of the last century, implant failure rates exceeding 10% are still reported. These numbers highlight the necessity of technologies to provide an accurate monitoring of the bone–implant interface state. This study provides a detailed review of the most relevant methodologies and technologies already proposed to monitor the loosening states of endoprosthetic implants, as well as their performance and experimental validation. A total of forty-two papers describing both intracorporeal and extracorporeal technologies for cemented or cementless fixation were thoroughly analyzed. Thirty-eight technologies were identified, which are categorized into five methodologies: vibrometric, acoustic, bioelectric impedance, magnetic induction, and strain. Research efforts were mainly focused on vibrometric and acoustic technologies. Differently, approaches based on bioelectric impedance, magnetic induction and strain have been less explored. Although most technologies are noninvasive and are able to monitor different loosening stages of endoprosthetic implants, they are not able to provide effective monitoring during daily living of patients.
Collapse
Affiliation(s)
- João Henrique Cachão
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Marco P. Soares dos Santos
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
- Associated Laboratory for Energy, Transports and Aeronautics (LAETA), 4150-179 Porto, Portugal
- Correspondence:
| | - Rodrigo Bernardo
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Ramos
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| | - Rainer Bader
- Department of Orthopedics, University Medicine Rostock, 18057 Rostock, Germany
| | - Jorge A. F. Ferreira
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Torres Marques
- Associated Laboratory for Energy, Transports and Aeronautics (LAETA), 4150-179 Porto, Portugal
- Mechanical Engineering Department, University of Porto, 4200-465 Porto, Portugal
| | - José A. O. Simões
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| |
Collapse
|
14
|
Mohammadbagherpoor H, Ierymenko P, Craver MH, Carlson J, Dausch D, Grant E, D Lucey J. An Implantable Wireless Inductive Sensor System Designed to Monitor Prosthesis Motion in Total Joint Replacement Surgery. IEEE Trans Biomed Eng 2019; 67:1718-1726. [PMID: 31562070 DOI: 10.1109/tbme.2019.2943808] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Currently, the most common method for detecting prosthetic implant loosening is imaging. Unfortunately, imaging methods are imprecise in detecting the early signs of implant loosening. This paper describes a new wireless inductive proximity sensor system for detecting early implant loosening. The loosening of the implant is accurately detected by analyzing the electromagnetic field generated by the passive sensors located around the implant. The sensor system was modeled and simulated using COMSOL, and then tested experimentally. The inductive proximity sensor and the metallic implant form a coupled circuit is tuned to oscillate at a designed frequency. The circuit's integrated controller measures and records specific sensor's parameters such as resistance and inductance of the sensor that are directly related to the distance between the sensor system and the implant. A prototype has been developed and the results show that the designed proximity sensor is capable of measuring the loosening of the hip implant at [Formula: see text]m resolution at distances of less than [Formula: see text], and of [Formula: see text]m resolution at a distance of [Formula: see text]. Furthermore, there is a good correlation between the simulated and experimental results.
Collapse
|
15
|
Impact Force, Polar Gap and Modal Parameters Predict Acetabular Cup Fixation: A Study on a Composite Bone. Ann Biomed Eng 2018; 46:590-604. [DOI: 10.1007/s10439-018-1980-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Accepted: 01/06/2018] [Indexed: 10/18/2022]
|