1
|
Wang Z, Jiang N, Jiang Z, Deng Q, Zhou Q, Hu B. Beyond silence: evolving ultrasound strategies in the battle against cardiovascular thrombotic challenges. J Thromb Thrombolysis 2024; 57:1040-1050. [PMID: 38689069 DOI: 10.1007/s11239-024-02989-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/18/2024] [Indexed: 05/02/2024]
Abstract
Cardiovascular thrombotic events have long been a perplexing factor in clinical settings, influencing patient prognoses significantly. Ultrasound-mediated acoustic therapy, an innovative thrombolytic treatment method known for its high efficiency, non-invasiveness, safety, and convenience, has demonstrated promising potential for clinical applications and has gradually become a focal point in cardiovascular thrombotic disease research. The current challenge lies in the technical complexities of preparing ultrasound-responsive carriers with thrombus-targeting capabilities and high thrombolytic efficiency. Additionally, optimizing the corresponding acoustic treatment mode is crucial to markedly enhance the thrombolytic effectiveness of ultrasound-mediated acoustic therapy. In light of the current status, this article provides a comprehensive review of the research progress in innovative ultrasound-mediated acoustic therapy for cardiovascular thrombotic diseases. It explores the impact of technical methods, therapeutic mechanisms, and influencing factors on the thrombolytic efficiency and clinical potential of ultrasound-mediated acoustic therapy. The review places particular emphasis on identifying solutions and key considerations in addressing the challenges associated with this cutting-edge therapeutic approach.
Collapse
Affiliation(s)
- Zhiwen Wang
- Echo Lab, Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, 238# Jiefang Road, Wuhan, 430060, Hubei, People's Republic of China
| | - Nan Jiang
- Echo Lab, Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, 238# Jiefang Road, Wuhan, 430060, Hubei, People's Republic of China
| | - Zhixin Jiang
- Echo Lab, Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, 238# Jiefang Road, Wuhan, 430060, Hubei, People's Republic of China
| | - Qing Deng
- Echo Lab, Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, 238# Jiefang Road, Wuhan, 430060, Hubei, People's Republic of China
| | - Qing Zhou
- Echo Lab, Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, 238# Jiefang Road, Wuhan, 430060, Hubei, People's Republic of China.
| | - Bo Hu
- Echo Lab, Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, 238# Jiefang Road, Wuhan, 430060, Hubei, People's Republic of China.
| |
Collapse
|
2
|
Tang J, Tang J, Liao Y, Bai L, Luo T, Xu Y, Liu Z. An in vitro comparative study on clot lysis efficiency of urokinase and reteplase with the synergy of ultrasound needle. Heliyon 2024; 10:e26624. [PMID: 38463819 PMCID: PMC10920158 DOI: 10.1016/j.heliyon.2024.e26624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 02/16/2024] [Accepted: 02/16/2024] [Indexed: 03/12/2024] Open
Abstract
Objectives Ultrasound Needle, which is an improved ultrasonic horn device, has shown great potential for promoting the diffusion of thrombolytic drugs within clots and enhancing clot lysis efficiency. However, the clot lysis efficiency of different thrombolytic drugs with the synergy of Ultrasound Needle remains unknown. In this study, we aimed to compare the lysis efficiency of the non-fibrin-specific drug urokinase and fibrin-specific drug reteplase with the synergy of Ultrasound Needle. Materials and methods Twenty-five milliliters of human blood was incubated for 1.5 h to form in vitro clots and then received the corresponding treatment protocols: control group (normal saline), US group (10 min of Ultrasound Needle treatment), UK group (30000IU of urokinase), r-PA group (2 mg of reteplase), US + UK group, and US + r-PA group. After treatment, the morphological changes of the clots were analyzed by B-mode ultrasound imaging and hematoxylin and eosin (H&E) staining. Lysis efficiency was evaluated based on the relative end weight (final weight/initial weight). The fibrin density of the different groups after treatment was assessed by immunofluorescence staining. Results Morphological examination and relative end weight analysis showed that combination therapies induced a more thorough dissolution of clots compared with single therapies, and the US + r-PA group exhibited higher lysis efficiency than the US + UK group. In addition, immunofluorescence staining showed that the US + r-PA group had fewer remaining thrombus fibrins than the US + UK group after treatment. Conclusions The Ultrasound Needle can significantly improve the clot lysis efficiency of both fibrinolytic drugs, and fibrin-specific reteplase exhibited superior lysis efficiency over non-fibrin-specific urokinase with the synergy of the Ultrasound Needle.
Collapse
Affiliation(s)
| | | | - Yiyi Liao
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, PR China
| | - Luhua Bai
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, PR China
| | - Tingting Luo
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, PR China
| | - Yali Xu
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, PR China
| | - Zheng Liu
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, PR China
| |
Collapse
|
3
|
Ward RE, Martinez-Correa S, Tierradentro-García LO, Hwang M, Sehgal CM. Sonothrombolysis: State-of-the-Art and Potential Applications in Children. CHILDREN (BASEL, SWITZERLAND) 2023; 11:57. [PMID: 38255371 PMCID: PMC10814591 DOI: 10.3390/children11010057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/15/2023] [Accepted: 12/27/2023] [Indexed: 01/24/2024]
Abstract
In recent years, advances in ultrasound therapeutics have been implemented into treatment algorithms for the adult population; however, the use of therapeutic ultrasound in the pediatric population still needs to be further elucidated. In order to better characterize the utilization and practicality of sonothrombolysis in the juvenile population, the authors conducted a literature review of current pediatric research in therapeutic ultrasound. The PubMed database was used to search for all clinical and preclinical studies detailing the use and applications of sonothrombolysis, with a focus on the pediatric population. As illustrated by various review articles, case studies, and original research, sonothrombolysis demonstrates efficacy and safety in clot dissolution in vitro and in animal studies, particularly when combined with microbubbles, with potential applications in conditions such as deep venous thrombosis, peripheral vascular disease, ischemic stroke, myocardial infarction, and pulmonary embolism. Although there is limited literature on the use of therapeutic ultrasound in children, mainly due to the lower prevalence of thrombotic events, sonothrombolysis shows potential as a noninvasive thrombolytic treatment. However, more pediatric sonothrombolysis research needs to be conducted to quantify the safety and ethical considerations specific to this vulnerable population.
Collapse
Affiliation(s)
- Rebecca E. Ward
- Department of Radiology, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA; (R.E.W.); (S.M.-C.); (L.O.T.-G.); (M.H.)
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Santiago Martinez-Correa
- Department of Radiology, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA; (R.E.W.); (S.M.-C.); (L.O.T.-G.); (M.H.)
| | - Luis Octavio Tierradentro-García
- Department of Radiology, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA; (R.E.W.); (S.M.-C.); (L.O.T.-G.); (M.H.)
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Misun Hwang
- Department of Radiology, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA; (R.E.W.); (S.M.-C.); (L.O.T.-G.); (M.H.)
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Chandra M. Sehgal
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
4
|
Yao L, Luo T, Yang G, Yin J, Li H, Liu Z. An Experimental Study: Treatment of Subcutaneous C6 Glioma in Rats Using Acoustic Droplet Vaporization. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:1951-1963. [PMID: 36916667 DOI: 10.1002/jum.16212] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 02/01/2023] [Accepted: 02/19/2023] [Indexed: 06/18/2023]
Abstract
OBJECTIVE The objective of this study was to investigate the treatment effects of acoustic droplet vaporization (ADV) on tumors. METHODS Experiments were conducted on subcutaneous C6 glioma implanted in 37 rats. Twenty-five rats were divided into five groups treated by ultrasound (US) + dodecafluoropentane (DDFP), US + microbubble (MB), US, DDFP, or saline, respectively. ADV was performed using DDFP droplets (2-5 μm) triggered by non-focused pulsed ultrasound. Macroscopic and histological changes of the tumor were compared with investigation of the tumor ablation effect of ADV. Tumor temperature was measured before and immediately after treatment to explore temperature changes. Furthermore, another 12 rats with bilateral tumors were divided into two groups. Six animals received ADV treatment on unilateral tumor, while another six received saline injection on unilateral tumor. The tumor blood perfusion, tumor volume and related immune response were measured. RESULTS The tumors treated by ADV were partially damaged without significant temperature rise. For the animals with bilateral tumors, the tumor blood perfusion around the damaged area on the side receiving ADV still existed. Additionally, the bilateral tumors of animals treated with ADV were smaller than those of animals treated with saline, along with stronger immune response and more tumor cell apoptosis in tumors on both sides. CONCLUSION The study demonstrated that ADV treatment could damage subcutaneous glioma in rats by mechanical effect and enhance systemic immune response to furtherly inhibit the tumor growth.
Collapse
Affiliation(s)
- Lei Yao
- Department of Ultrasound, The Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Tingting Luo
- Department of Ultrasound, The Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Guoliang Yang
- Department of Ultrasound, The Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Jiabei Yin
- Department of Ultrasound, The Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Hui Li
- Department of Ultrasound, The Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Zheng Liu
- Department of Ultrasound, The Second Affiliated Hospital of Army Medical University, Chongqing, China
| |
Collapse
|
5
|
Dadgar MM, Hynynen K. High-Pressure Low-Frequency Lateral Mode Phased-Array Transducer System for the Treatment of Deep Vein Thrombosis: An In Vitro Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1088-1099. [PMID: 35020593 DOI: 10.1109/tuffc.2022.3141871] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Deep vein thrombosis (DVT) can lead to a fatal disease known as pulmonary embolism. Application of high-power ultrasound has been successful in studies to mechanically fragment the clots. Single-element ultrasound transducers were used in most of the studies. Challenges associated with phased arrays, such as high electrical impedance and element breakdown at high voltages, were addressed in the previous study, and a high-power 64-element transducer module was designed and fabricated. In this study, a cylindrical array of 16 modules with the frequency of 260 kHz was modeled and constructed for DVT thrombolysis. The maximum pressure, focal size, and steering ability of the array were examined. In vitro experiments were conducted to assess the performance of the array. The simulated pressure amplitude of 34 MPa at the depth of 55 mm (average femoral vein (FV) distance from the inner surface of the thigh) was in consistent with the experiments and satisfied the purpose of this study. Moreover, the employed module distribution resulted in a focal spot dimension of 2.4×2.8×7.3 mm3 (at the 75% pressure amplitude level) that can be confined in a human FV with the average diameter of 12 mm. In vitro experiments manifested a partial and complete clot breakdown at 11.5- and 15-MPa pressure at the focus. The design and engineering of the array system was succeeded in maintaining the desired pressure and focal size even when steered. The results presented in this study suggest the potential of the designed array system for clinical applications.
Collapse
|
6
|
Zhu Q, Xu X, Chen B, Liao Y, Guan X, He Y, Cui H, Rong Y, Liu Z, Xu Y. Ultrasound targeted microbubble destruction assists dual delivery of beta-amyloid antibody and neural stem cells to restore neural function in transgenic mice of Alzheimer's disease. Med Phys 2022; 49:1357-1367. [PMID: 35092698 DOI: 10.1002/mp.15500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES To explore the feasibility, efficacy and safety of ultrasound targeted microbubbles destruction (UTMD) assisted dual delivery of beta-amyloid (Aβ) antibody loaded by microbubbles (MBAβ ) and neural stem cells (NSCs) on Alzheimer's disease (AD). METHODS 27 APP/PS1 double transgenic mice (Tg mice) and 33 wild-type mice were used. Wild-type mice were insonated by diagnostic ultrasound with microbubbles (MB) for 5 min to observe the blood brain barrier (BBB) opening. The survival situation of engrafted NSCs crossing the opened BBB mediated by UTMD in AD mice was evaluated by in vivo imaging system. We further explored the combination therapy of UTMD mediated Aβ antibody and NSCs dual delivery. Tg mice in each group were exposed to diagnostic ultrasound for 5 min once a week for four times, with MB, MBAβ , and/or NSCs administration. Cognition and memory functions were explored by Morris water maze test, Aβ plaques deposition was evaluated by immunohistochemical, and brain-derived neurotrophic factor (BDNF) and synaptophysin (SYN) expression were detected by western blot and immunofluorescence. RESULTS BBB was opened mediated by diagnostic ultrasound with MB and the duration of opening was about 10 h. The transplanted NSCs survived in Tg mice for no more than 72 h. Compared with control group, the mice in combined delivery of NSCs and Aβ antibody by UTMD group improved memory function and spatial learning with shorter latency to find the platform, longer distance traveled and longer time spent in targeted quadrant, and more crossing times (P < 0.05). Besides, the combination delivery group promoted the clearance of Aβ plaques compared with control group both in hippocampus (P < 0.01) and cortex (P < 0.05). Moreover, the expression of BDNF in combination delivery group was significantly higher than that in control group and US mediated MB group (P < 0.05). No significant change of SYN was observed in each group. CONCLUSION UTMD assisted dual delivery of Aβ antibody and NSCs to AD mice brain could help to clear Aβ plaques, increase the expression of BDNF and restore the impaired neural function. This finding may offer potential insight into treatment of AD. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Qiong Zhu
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China
| | - Xiaoxun Xu
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China
| | - Beibei Chen
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China.,Postgraduate Training base of Jinzhou Medical University, Jinzhou, 121000, China
| | - Yiyi Liao
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China
| | - Xue Guan
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China
| | - Ying He
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China
| | - Hai Cui
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China.,Department of Ultrasound, Armed Police Force Hospital, Sichuan, 614000, China
| | - Yani Rong
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China
| | - Zheng Liu
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China
| | - Yali Xu
- Department of Ultrasound, Xinqiao Hospital of Army Medical University, Chongqing, 400038, China
| |
Collapse
|
7
|
Tang J, Tang J, Zhu Q, Liao Y, Bai L, Luo T, Feng S, Liu Z. A minimally invasive strategy to evacuate hematoma by synergy of an improved ultrasonic horn with urokinase: an in-vitro study. Med Phys 2022; 49:1333-1343. [PMID: 35018646 DOI: 10.1002/mp.15453] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 12/21/2021] [Accepted: 12/21/2021] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVES In this study, Ultrasound Needle-an improved minimally invasive ultrasonic horn device was used to explore its potential of synergizing with urokinase in enhancing clots lysis in an in-vitro intracranial hematoma model. MATERIALS AND METHODS 10 ml bovine blood was incubated for 3 h at 37 ℃, and coagulated into clot to mimic intracranial hematoma in-vitro. Ultrasound Needle was an improved ultrasonic horn with a fine tip (1.80 mm) and metallic sheath, and had a frequency of 29.62 kHz. 10000 IU urokinase was injected through the metallic sheath during the vibration of Ultrasound Needle tip to lyse the clots for 8 minutes under different working parameter settings (n = 8) to explore the influence of parameters Amplitude (%) and Duty (%) on clot lysis weight (W0 ). The maximum temperatures were measured by an infrared thermometer during the treatment process. The W0 of different treatment groups (US (Ultrasound Needle), US+NS (normal saline), UK (urokinase), US+UK, n = 8) were compared to verify the synergistic lysis effect of Ultrasound Needle combined with urokinase at optimal working parameters (40% Amplitude, 20% Duty; input power 4.20 W; axial tip-vibration amplitude 69.17 μm). Clots samples after treatment were fixed overnight for macroscopic examination. And fluorescent frozen sections and scanning electron microscopy examination were performed to show microscopic changes in clots and evaluate the cavitation effect of Ultrasound Needle on promoting drug diffusion within the clots. RESULTS The clot lysis weight W0 increased with the parameters Amplitude (%) and Duty (%), reached a peak (2.435±0.137 g) at 40% Amplitude and 20% Duty (input power 4.20 W), and then decreased. Higher Amplitude (%) and Duty (%) led to higher maximum temperature, and W0 was negatively correlated with the maximum temperature after the peak (r = -0.958). At the optimal parameter setting, the maximum temperature was 33.8±0.9 ℃, and the W0 of the US+UK group was more than 4 times of UK alone group (2.435±0.137 g vs 0.607±0.185 g). Fluorescent frozen sections confirmed that the ultrasound energy of Ultrasound Needle could mechanically damage the clot tissues and promote the intra-clots drug diffusion. Macroscopic examination showed that US+UK group caused larger clots lysis area than UK alone group (2.08 cm2 vs 0.65 cm2 ). In addition, electron microscopy examination exhibited that the fibrin filaments of the clots in US+UK group were lysed more thoroughly compared to single treatment groups. CONCLUSIONS Ultrasound Needle, an improved ultrasonic horn device, can mechanically damage the clot tissues and exhibit an excellent synergistic lysis effect with thrombolytic drugs. Therefore, Ultrasound Needle has great potential in providing a new minimally invasive strategy for rapid intracranial hematoma evacuation. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Junhui Tang
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Jiawei Tang
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Qiong Zhu
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Yiyi Liao
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Luhua Bai
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Tingting Luo
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Shuang Feng
- Department of Ultrasound, General Hospital of Southern Theatre Command, Guangzhou, China
| | - Zheng Liu
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| |
Collapse
|
8
|
Drug-Loaded Microbubbles Combined with Ultrasound for Thrombolysis and Malignant Tumor Therapy. BIOMED RESEARCH INTERNATIONAL 2019; 2019:6792465. [PMID: 31662987 PMCID: PMC6791276 DOI: 10.1155/2019/6792465] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 07/22/2019] [Accepted: 09/14/2019] [Indexed: 12/14/2022]
Abstract
Cardiac-cerebral thrombosis and malignant tumor endanger the safety of human life seriously. Traditional chemotherapy drugs have side effects which restrict their applications. Drug-loaded microbubbles can be destroyed by ultrasound irradiation at the focus position and be used for thrombolysis and tumor therapy. Compared with traditional drug treatment, the drug-loaded microbubbles can be excited by ultrasound and release drugs to lesion sites, increasing the local drug concentration and the exposure dose to nonfocal regions, thus reducing the cytotoxicity and side effects of drugs. This article reviews the applications of drug-loaded microbubbles combined with ultrasound for thrombolysis and tumor therapy. We focus on highlighting the advantages of using this new technique for disease treatment and concluding with recommendations for future efforts on the applications of this technology.
Collapse
|
9
|
Zhu Q, Dong G, Wang Z, Sun L, Gao S, Liu Z. Intra-clot Microbubble-Enhanced Ultrasound Accelerates Catheter-Directed Thrombolysis for Deep Vein Thrombosis: A Clinical Study. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2427-2433. [PMID: 31160122 DOI: 10.1016/j.ultrasmedbio.2019.04.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 04/14/2019] [Accepted: 04/25/2019] [Indexed: 06/09/2023]
Abstract
Insufficiency of microbubbles in the vessel-obstructing thrombus significantly reduces the effectiveness of ultrasound thrombolysis. With catheter-directed thrombolysis (CDT), microbubbles can be delivered directly into the thrombus. In this study, we combined CDT with intra-clot microbubble-enhanced ultrasound thrombolysis (IMUT) to investigate its safety and efficiency in thrombolysis in patients with acute lower limb deep vein thrombosis (DVT). For IMUT, a 1-MHz air-backed transducer directed 100-μs-pulse-length and 100-Hz-pulse-repetition pressure at 1 MPa was used. Thirteen DVT patients in the study group were treated with CDT and IMUT. Forty-three DVT patients in the historical control group were treated with CDT alone. The results indicated that the average thrombolysis time of the study group was significantly shorter (5.23 ± 1.59 d) than that of the control (10.00 ± 2.69 d), and the overall urokinase dosage of the study group ([3.82 ± 1.68] × 106 IU) was lower than that of the control ([4.99 ± 2.26] × 106 IU). No procedure-related complications were noted in either group. Therefore, combining CDT with IMUT can improve thrombolysis safely and efficiently.
Collapse
Affiliation(s)
- Qiong Zhu
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Gang Dong
- Department of Ultrasound, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Zhiwei Wang
- Department of Vascular Surgery, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Lulu Sun
- Department of Ultrasound, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Shunji Gao
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China; Department of Ultrasound, Central Theater Command General Hospital of the Chinese People's Liberation Army, Wuhan, China
| | - Zheng Liu
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China.
| |
Collapse
|
10
|
Liu M, Zhang F. Administration routes affect thrombolytic effect of catheter-directed thrombolysis with pro-urokinase in treating deep vein thrombosis. ANNALS OF TRANSLATIONAL MEDICINE 2018; 6:322. [PMID: 30364011 DOI: 10.21037/atm.2018.08.01] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Background Deep venous thrombosis (DVT) is a common disorder with a significant mortality rate. Catheter-directed thrombolysis (CDT) is a preferred treatment for DVT patients. The aim of this study is to evaluate the thrombolytic effect of CDT with pro-urokinase (pro-UK) in different administration routes. Methods An inferior vena cava (IVC) model was induced in 36 New Zealand white rabbits by catheter injury and placement of IVC filter. The animals were divided into 6 groups with 6 rabbits in each group: group A: systemic thrombolysis with intravenous injection; group B: CDT with pump infusion; group C: CDT with pulse injection; group D: CDT with combination of pump infusion and pulse injection; group E: catheter-directed aspiration thrombectomy; group F: mechanical thrombectomy. The thrombolytic effects were evaluated by color Doppler ultrasound and blood measurement of D-dimer and fibrinogen. Results The minimum effective concentration of pro-UK solution was identified. Two groups (group A and B) did not achieve successful thrombolysis. Among all catheter-directed administration groups, the rabbit groups that received pro-UK therapy through catheter-directed thrombolytic pump infusion combined with pulse injection (group D) showed the best thrombolysis effect. In contrast, catheter-directed aspiration thrombectomy (group E) is effective but not safe. Conclusions CDT with combination of pump infusion and pulse injection of pro-UK safely and significantly improves thrombolysis procedure in rabbits, suggesting potential benefits from the use of CDT in proximal DVT.
Collapse
Affiliation(s)
- Meng Liu
- Department of Vascular Surgery, Beijing Shijitan Hospital, Capital Medical University, Beijing 100038, China.,Department of Vascular Surgery, Tianjin Hospital, Tianjin 300211, China
| | - Fuxian Zhang
- Department of Vascular Surgery, Beijing Shijitan Hospital, Capital Medical University, Beijing 100038, China
| |
Collapse
|
11
|
Chen Z, Zhao H, Qiao X, Yi C, Gao S, Gao W, Liu Z. Effect of Microbubble-Enhanced Ultrasound on Radiofrequency Ablation of Rabbit Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1451-1459. [PMID: 29685588 DOI: 10.1016/j.ultrasmedbio.2018.03.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Revised: 02/02/2018] [Accepted: 03/14/2018] [Indexed: 06/08/2023]
Abstract
Microbubble-enhanced ultrasound (MEUS) can non-invasively disrupt and block liver blood perfusion. It may potentially overcome the heat sink effect during a thermal ablation and consequently enhance radiofrequency ablation (RFA) of the liver. We propose a new strategy combining RFA with MEUS. For ultrasound treatment, an 831-kHz air-backed focused transducer directed 400-cycle bursts at 4.3 MPa to the liver at a 9-Hz rate. The treatment was nucleated by a lipids microbubble forming MEUS. Eighteen surgically exposed rabbit livers were treated using MEUS combined with RFA; the other 32 livers were treated using MEUS (n = 14) or RFA (n = 18) alone and served as the controls. Contrast ultrasound imaging confirmed that MEUS treatment significantly reduced liver blood perfusion by cutting contrast peak intensities in half (44.7%-54.1%) without severe liver function damage. The ablated liver volume treated using MEUS combined with RFA was 2.8 times greater than that treated using RFA alone. In conclusion, RFA of the liver can be safely and greatly enhanced by combination with MEUS pre-treatment.
Collapse
Affiliation(s)
- Zhong Chen
- Department of Ultrasound, Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Hongzhi Zhao
- Department of Hepatobiliary Surgery, Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Xueyan Qiao
- Department of Ultrasound, Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Cuo Yi
- Department of Ultrasound, Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Shunji Gao
- Department of Ultrasound, Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Wenhong Gao
- Department of Ultrasound, Second Affiliated Hospital of Army Medical University, Chongqing, China
| | - Zheng Liu
- Department of Ultrasound, Second Affiliated Hospital of Army Medical University, Chongqing, China.
| |
Collapse
|
12
|
Teng Y, Jin H, Nan D, Li M, Fan C, Liu Y, Lv P, Cui W, Sun Y, Hao H, Qu X, Yang Z, Huang Y. In vivo evaluation of urokinase-loaded hollow nanogels for sonothrombolysis on suture embolization-induced acute ischemic stroke rat model. Bioact Mater 2017; 3:102-109. [PMID: 29744447 PMCID: PMC5935765 DOI: 10.1016/j.bioactmat.2017.08.001] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 08/09/2017] [Accepted: 08/17/2017] [Indexed: 12/25/2022] Open
Abstract
The urokinase-type plasminogen activator (uPA) loaded hollow nanogels (nUK) were synthesized by a one-step reaction of glycol chitosan and aldehyde capped poly (ethylene oxide). The resultant formulation is sensitive to diagnostic ultrasound (US) of 2 MHz. Herein, we evaluated the in vivo sonothrombolysis performance of the nUK on acute ischemic stroke rat model which was established by suture embolization of middle cerebral artery (MCA). Via intravenous (i.v.) administration, the experimental data prove a controlled release of the therapeutic protein around the clots under ultrasound stimulation, leading to enhanced thrombolysis efficiency of the nUK, evidenced from smaller infarct volume and better clinical scores when compared to the i.v. dose of free uPA no matter with or without US intervention. Meanwhile, the preservation ability of the nanogels not only prolonged the circulation duration of the protein, but also resulted in the better blood-brain barrier protection of the nUK formulation, showing no increased risk on the hemorrhagic transformation than the controls. This work suggests that the nUK is a safe sonothrombolytic formulation for the treatment of acute ischemic stroke. Ultrasonic responsive urokinase (uPA)-loaded hollow nanogels (nUK) were synthesized for stroke treatment. Acute ischemic stroke rat model was established by suture embolization of middle cerebral artery. The nUK enhanced the sonothrombolytic efficacy and led to better BBB protection compared to the free uPA.
Collapse
Key Words
- BBB, blood-brain barrier
- CCA, common carotid artery
- EB, evens blue
- ELIP, echogenic liposomes
- HT, hemorrhagic transformation
- Hb, hemoglobin
- Hollow nanogel
- In vivo evaluation
- MCA, middle cerebral artery
- MCAO, middle cerebral artery occlusion
- MRI, magnetic resonance imaging
- SD, Sprague-Dawley
- TCD, Transcranial Doppler
- TTC, 2,3,5-triphenyltetrazolium chloride
- Thrombolysis
- UK+US, ultrasound and free urokinase
- UK, urokinase
- US, ultrasound
- Ultrasound responsive
- Urokinase delivery
- nUK+US, ultrasound and uPA-loaded nanogels
- nUK, uPA-loaded nanogels
Collapse
Affiliation(s)
- Yuming Teng
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Haiqiang Jin
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Ding Nan
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Mengnan Li
- State Key Laboratory of Polymer Physics and Chemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Chenghe Fan
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Yuanyuan Liu
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Pu Lv
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Wei Cui
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Yongan Sun
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Hongjun Hao
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| | - Xiaozhong Qu
- College of Materials and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhenzhong Yang
- State Key Laboratory of Polymer Physics and Chemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Yining Huang
- Department of Neurology, Peking University First Hospital, Beijing 100034, China
| |
Collapse
|