1
|
Padmanabhan S, Prakash J. Deep tissue sensing of chiral molecules using polarization-enhanced photoacoustics. SCIENCE ADVANCES 2025; 11:eado8012. [PMID: 40106566 PMCID: PMC11922051 DOI: 10.1126/sciadv.ado8012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 02/10/2025] [Indexed: 03/22/2025]
Abstract
Chiral molecule sensing is typically performed using techniques like chromatography, electrophoresis, enzymatic assays, mass spectrometry, and chiroptical methods. While polarimetry allows for in vivo sensing up to 1 mm depth using ultraviolet-visible light, it is limited by dominant light scattering beyond this depth. We propose that photoacoustic sensing in the near-infrared II (NIR-II) window can enable deep tissue sensing as acoustic waves scatter less than light. To achieve this, we developed a photoacoustic polarization-enhanced optical rotation sensing (PAPEORS) system, capable of estimating optical rotation from photoacoustic signals and correlating it with chiral molecular concentration for depths up to 3.5 mm. Experiments were conducted using aqueous glucose solutions, naproxen, serum-based glucose samples, and ex vivo chicken tissue. PAPEORS achieved a detection limit of 80 mg/dl while using circularly polarized light with serum samples, demonstrating the potential for deep-tissue chiral molecular sensing. PAPEORS holds promise for in vivo sensing and easy miniaturization using single wavelength.
Collapse
Affiliation(s)
- Swathi Padmanabhan
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bengaluru 560012, India
| | - Jaya Prakash
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bengaluru 560012, India
| |
Collapse
|
2
|
Putzu A, Grange E, Schorer R, Schiffer E, Gariani K. Continuous peri-operative glucose monitoring in noncardiac surgery: A systematic review. Eur J Anaesthesiol 2025; 42:162-171. [PMID: 39512161 DOI: 10.1097/eja.0000000000002095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2024]
Abstract
BACKGROUND Glucose management is an important component of peri-operative care. The usefulness of continuous glucose monitoring (CGM) in noncardiac surgery is uncertain. OBJECTIVE To systematically assess the glycaemic profile and clinical outcome of patients equipped with a CGM device during the peri-operative period in noncardiac surgery. DESIGN Systematic review. DATA SOURCES Electronic databases were systematically searched up to July 2024. ELIGIBILITY CRITERIA Any studies performed in the peri-operative setting using a CGM device were included. Closed-loop systems also administering insulin were excluded. Analyses were stratified according to diabetes mellitus status and covered intra-operative and postoperative data. Outcomes included glycaemic profile (normal range 3.9 to 10.0 mmol l -1 ), complications, adverse events, and device dysfunction. RESULTS Twenty-six studies (1016 patients) were included. Twenty-four studies were not randomised, and six used a control arm for comparison. In bariatric surgery, diabetes mellitus patients had a mean ± SD glucose of 5.6 ± 0.5 mmol l -1 , with 15.4 ± 8.6% time below range, 75.3 ± 5.5% in range and 9.6 ± 6.7% above range. During major surgery, diabetes mellitus patients showed a mean glucose of 9.6 ± 1.1 mmol l -1 , with 9.5 ± 9.1% of time below range, 56.3 ± 13.5% in range and 30.6 ± 13.9% above range. In comparison, nondiabetes mellitus patients had a mean glucose of 6.4 ± 0.6 mmol l -1 , with 6.7 ± 8.4% time below range, 84.6 ± 15.5% in range and 11.2 ± 4.9% above range. Peri-operative complications were reported in only one comparative study and were similar in CGM and control groups. Device-related adverse events were rare and underreported. In 9.21% of cases, the devices experienced dysfunctions such as accidental removal and issues with sensors or readers. CONCLUSION Due to the limited number of controlled studies, the impact of CGM on postoperative glycaemic control and complications compared with point-of-care testing remains unknown. Variability in postoperative glycaemic profiles and a device dysfunction rate of 1 in 10 suggest CGM should be investigated in a targeted surgical group.
Collapse
Affiliation(s)
- Alessandro Putzu
- From the Division of Anaesthesiology, Department of Anaesthesiology, Pharmacology, Intensive Care and Emergency Medicine, Geneva University Hospitals (AP, EG, RS, ES), Faculty of Medicine, University of Geneva (ES) and Division of Endocrinology, Diabetes, Nutrition and Therapeutic Patient Education, Department of Medical Specialties, Geneva University Hospitals, Geneva, Switzerland (KG)
| | | | | | | | | |
Collapse
|
3
|
Hughes MS, Aleppo G, Bally L, Batista AFMB, Brown SA, Faulds ER, Gonder-Frederick LA, Isaacs D, Kahkoska AR, Ortega J, Polonsky WH, Stumpf MM. Diabetes Technology Use in Special Populations: A Narrative Review of Psychosocial Factors. J Diabetes Sci Technol 2025; 19:34-46. [PMID: 39564761 PMCID: PMC11577555 DOI: 10.1177/19322968241296853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2024]
Abstract
As diabetes technologies continue to advance, their use is expanding beyond type 1 diabetes to include populations with type 2 diabetes, older adults, pregnant individuals, those with psychiatric conditions, and hospitalized patients. This review examines the psychosocial outcomes of these technologies across these diverse groups, with a focus on treatment satisfaction, quality of life, and self-management behaviors. Despite demonstrated benefits in glycemic outcomes, the adoption and sustained use of these technologies face unique challenges in each population. By highlighting existing research and identifying gaps, this review seeks to emphasize the need for targeted studies and tailored support strategies to understand and optimize psychosocial outcomes and well-being.
Collapse
Affiliation(s)
- Michael S. Hughes
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA, USA
| | - Grazia Aleppo
- Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Lia Bally
- Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | | | - Sue A. Brown
- Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
- Division of Endocrinology, Department of Medicine, University of Virginia, Charlottesville, VA, USA
| | - Eileen R. Faulds
- College of Nursing, The Ohio State University, Columbus, OH, USA
| | | | - Diana Isaacs
- Diabetes Center, Cleveland Clinic, Cleveland, OH, USA
| | - Anna R. Kahkoska
- Department of Nutrition, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
- Division of Endocrinology and Metabolism, School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
- Center for Aging and Health, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Jacob Ortega
- School of Osteopathic Medicine, Campbell University, Lillington, NC, USA
| | - William H. Polonsky
- Behavioral Diabetes Institute, San Diego, CA, USA
- University of California San Diego, San Diego, CA, USA
| | - Meaghan M. Stumpf
- Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
- Division of Endocrinology, Department of Medicine, University of Virginia, Charlottesville, VA, USA
| |
Collapse
|
4
|
Nielsen CG, Grigonyte-Daraskeviciene M, Olsen MT, Møller MH, Nørgaard K, Perner A, Mårtensson J, Pedersen-Bjergaard U, Kristensen PL, Bestle MH. Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review. Intensive Care Med 2024; 50:2005-2018. [PMID: 39417874 DOI: 10.1007/s00134-024-07663-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Accepted: 09/14/2024] [Indexed: 10/19/2024]
Abstract
PURPOSE Glycemic control poses a challenge in intensive care unit (ICU) patients and dysglycemia is associated with poor outcomes. Continuous glucose monitoring (CGM) has been successfully implemented in the type 1 diabetes out-patient setting and renewed interest has been directed into the transition of CGM into the ICU. This scoping review aimed to provide an overview of CGM accuracy in ICU patients to inform future research and CGM implementation. METHODS We systematically searched PubMed and EMBASE between 5th of December 2023 and 21st of May 2024 and reported findings in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline for scoping reviews (PRISMA-ScR). We assessed studies reporting the accuracy of CGM in the ICU and report study characteristics and accuracy outcomes. RESULTS We identified 2133 studies, of which 96 were included. Most studies were observational (91.7%), conducted in adult patients (74%), in mixed ICUs (47.9%), from 2014 and onward, and assessed subcutaneous CGM systems (80%) using arterial blood samples as reference test (40.6%). Half of the studies (56.3%) mention the use of a prespecified reference test protocol. The mean absolute relative difference (MARD) ranged from 6.6 to 30.5% for all subcutaneous CGM studies. For newer factory calibrated CGM, MARD ranged from 9.7 to 20.6%. MARD for intravenous CGM was 5-14.2% and 6.4-13% for intraarterial CGM. CONCLUSIONS In this scoping review of CGM accuracy in the ICU, we found great diversity in accuracy reporting. Accuracy varied depending on CGM and comparator, and may be better for intravascular CGM and potentially lower during hypoglycemia.
Collapse
Affiliation(s)
- Christian G Nielsen
- Department of Anesthesiology and Intensive Care, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark.
| | | | - Mikkel T Olsen
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
| | - Morten H Møller
- Department of Intensive Care, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Kirsten Nørgaard
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Clinical Translational Research, Steno Diabetes Center Copenhagen, Herlev, Denmark
| | - Anders Perner
- Department of Intensive Care, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Johan Mårtensson
- Department of Physiology and Pharmacology, Section of Anesthesia and Intensive Care, Karolinska Institutet, Stockholm, Sweden
- Department of Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden
| | - Ulrik Pedersen-Bjergaard
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Peter L Kristensen
- Department of Endocrinology and Nephrology, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Morten H Bestle
- Department of Anesthesiology and Intensive Care, Copenhagen University Hospital-North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
5
|
Morales-Dopico L, MacLeish SA. Expanding the horizon of continuous glucose monitoring into the future of pediatric medicine. Pediatr Res 2024; 96:1464-1474. [PMID: 39306610 PMCID: PMC11624137 DOI: 10.1038/s41390-024-03573-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 08/01/2024] [Accepted: 09/05/2024] [Indexed: 12/08/2024]
Abstract
Glucose monitoring has rapidly evolved with the development of minimally invasive continuous glucose monitoring (CGM) using interstitial fluid. It is recommended as standard of care in the ambulatory setting, nearly replacing capillary glucose testing in those with access to CGM. The newest CGM devices continue to be smaller and more accurate, and integration with automated insulin delivery systems has further revolutionized the management of diabetes, leading to successful improvements in care and quality of life. Many studies confirm accuracy and application of CGM in various adult inpatient settings. Studies in adult patients increased during the COVID 19 Pandemic, but despite reassuring results, inpatient CGM use is not yet approved by the FDA. There is a lack of studies in inpatient pediatric settings, although data from the NICU and PICU have started to emerge. Given the exponential increase in the use of CGM, it is imperative that hospitals develop protocols for CGM use, with a need for ongoing implementation research. In this review we describe how CGM systems work, discuss benefits and barriers, summarize research in inpatient pediatric CGM use, explore gaps in research design along with emerging recommendations for inpatient use, and discuss overall CGM utility beyond outpatient diabetes management. IMPACT: Current CGM systems allow for uninterrupted monitoring of interstitial glucose excursions, and have triggered multiple innovations including automated insulin delivery. CGM technology has become part of standard of care for outpatient diabetes management, endorsed by many international medical societies, now with significant uptake, replacing capillary glucose testing for daily management in patients with access to CGM technology. Although CGM is not approved by the FDA for inpatient hospital use, studies in adult settings support its use in hospitals. More studies are needed for pediatrics. Implementation research is paramount to expand the role of CGM in the inpatient setting and beyond.
Collapse
Affiliation(s)
- Lourdes Morales-Dopico
- Pediatric Endocrinology Fellow, CWRU School of Medicine, University Hospitals Cleveland Medical Center, Rainbow Babies and Children's Hospital, Cleveland, OH, USA.
| | - Sarah A MacLeish
- Associate Professor of Pediatrics, Pediatric Endocrinology, CWRU School of Medicine, University Hospitals Cleveland Medical Center, Rainbow Babies and Children's Hospital, Cleveland, OH, USA
| |
Collapse
|
6
|
Bann SA, Hercus JC, Atkins P, Alkhairy A, Loyal JP, Sekhon M, Thompson DJ. Accuracy of a Continuous Glucose Monitor in the Intensive Care Unit: A Proposed Accuracy Standard and Calibration Protocol for Inpatient Use. Diabetes Technol Ther 2024; 26:797-805. [PMID: 38913325 DOI: 10.1089/dia.2024.0074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/25/2024]
Abstract
Background and Aims: Guidelines now recommend inpatient continuous glucose monitor (CGM) use with confirmatory blood glucose measurements. However, the Food and Drug Administration has not yet officially approved CGM for inpatient use in large part because its accuracy has not been established in this setting. We tested the accuracy of the Dexcom G6 (G6) in 28 adults on an insulin infusion in a medical-surgical intensive care unit with 1064 matched CGM and arterial point-of-care pairs. Methods: The participants were on average 57.29 (SD 2.39) years, of whom 13 had a prior diagnosis of diabetes and 14 were admitted for a surgical diagnosis. The first 19 participants received the G6 without calibration and had a mean absolute relative difference (MARD) of 13.19% (IQR 5.11, 19.03) across 659 matched pairs, which just meets the critical care expert recommendation of MARD <14%. We then aimed to improve accuracy for the subsequent 9 participants using a calibration protocol. Results: The MARD for calibrated participants was 9.65% (3.03, 13.33), significantly lower than for uncalibrated participants (P < 0.001). Calibration also demonstrated excellent safety with 100% of values within the Clarke Error Grid zones A and B compared with 99.07% without calibration. Our protocol achieved the lowest MARD and safest CEG profile in the critical care setting and well exceeds the critical care expert recommendations. Our large sample of heterogenous critically ill patients also reached comparable accuracy to the MARD of 9% for G6 in outpatients. We believe our calibration protocol will allow G6 to be used with sufficient accuracy in inpatients.
Collapse
Affiliation(s)
- Sewon A Bann
- Division of Endocrinology, University of British Columbia, Vancouver, Canada
| | - Jess C Hercus
- Department of Biological Sciences, Simon Fraser University, Burnaby, Canada
| | - Paul Atkins
- Division of Endocrinology, University of British Columbia, Vancouver, Canada
| | - Areej Alkhairy
- Division of Endocrinology, University of British Columbia, Vancouver, Canada
| | - Jackson P Loyal
- Deanery of Molecular, Genetic and Population Health Sciences, University of Edinburgh, Edinburgh, UK
| | - Mypinder Sekhon
- Division of Critical Care, University of British Columbia, Vancouver, Canada
| | - David J Thompson
- Division of Endocrinology, University of British Columbia, Vancouver, Canada
| |
Collapse
|
7
|
Philis-Tsimikas A, San Diego ERN, Vincent L, Lohnes S, Singleton C. Are we Ready for Real-Time Continuous Glucose Monitoring in the Hospital Setting? Benefits, Challenges, and Practical Approaches for Implementation : Case Vignette: Remote Real-Time Continuous Glucose Monitoring for Hospitalized Care in Quincy Koala. Curr Diab Rep 2024; 24:217-226. [PMID: 39126617 DOI: 10.1007/s11892-024-01549-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/16/2024] [Indexed: 08/12/2024]
Abstract
PURPOSE OF REVIEW While preliminary evidence for use of real-time continuous glucose monitoring (rtCGM) in the hospital setting is encouraging, challenges with currently available devices and technology will need to be overcome as part of real-world integration. This paper reviews the current evidence and guidelines regarding use of rtCGM in the hospital and suggests a practical approach to implementation. RECENT FINDINGS There is now a considerable body of real-world evidence on the benefits of reducing dysglycemia in the hospital using both traditional point-of-care (POC) glucose testing and rtCGM. Benefits of rtCGM include decreased frequency of hypo- and hyperglycemia with reduced need of frequent POC checks and it is both feasible and well-accepted by nursing staff and providers. If expansion to additional sites is to be considered, practical solutions will need to be offered. Recommendations for an operational workflow and tools are described to guide implementation in the non-ICU setting. Further testing in randomized controlled trials and real-world dissemination and implementation designs is needed, together with industry and technology collaborations, to further streamline the integration into health systems.
Collapse
Affiliation(s)
- Athena Philis-Tsimikas
- Scripps Whittier Diabetes Institute, 9834 Genesee Ave, Suite 300, La Jolla, CA, 92037, USA.
| | - Emily Rose N San Diego
- Scripps Whittier Diabetes Institute, 9834 Genesee Ave, Suite 300, La Jolla, CA, 92037, USA
- Scripps Research Translational Institute, La Jolla, CA, USA
| | - Lauren Vincent
- Scripps Whittier Diabetes Institute, 9834 Genesee Ave, Suite 300, La Jolla, CA, 92037, USA
- Scripps Health Inpatient Providers Medical Group, San Diego, CA, USA
| | - Suzanne Lohnes
- Scripps Whittier Diabetes Institute, 9834 Genesee Ave, Suite 300, La Jolla, CA, 92037, USA
| | | |
Collapse
|
8
|
Lee MY, Seav SM, Ongwela L, Lee JJ, Aubyrn R, Cao FY, Kalinsky A, Aparicio Ramos O, Gu Y, Kingston K, Ivanovic M, Buckingham BA, Desai D, Lal RA, Tan M, Basina M, Hughes MS. Empowering Hospitalized Patients With Diabetes: Implementation of a Hospital-wide CGM Policy With EHR-Integrated Validation for Dosing Insulin. Diabetes Care 2024; 47:1838-1845. [PMID: 39140891 PMCID: PMC11417271 DOI: 10.2337/dc24-0626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 07/28/2024] [Indexed: 08/15/2024]
Abstract
OBJECTIVE We aimed to assess the feasibility, clinical accuracy, and acceptance of a hospital-wide continuous glucose monitoring (CGM) policy with electronic health record (EHR)-integrated validation for insulin dosing. RESEARCH DESIGN AND METHODS A hospital policy was developed and implemented at Stanford Health Care for using personal CGMs in lieu of fingerstick blood glucose (FSBG) monitoring. It included requirements specific to each CGM, accuracy monitoring protocols, and EHR integration. User experience surveys were conducted among a subset of patients and nurses. RESULTS From November 2022 to August 2023, 135 patients used the CGM protocol in 185 inpatient encounters. This group included 27% with type 1 diabetes and 24% with automated insulin delivery systems. The most-used CGMs were Dexcom G6 (44%) and FreeStyle Libre 2 (43%). Of 1,506 CGM validation attempts, 87.8% met the 20% or 20 mg/dL (%20/20) criterion for CGM-based insulin dosing and 99.3% fell within Clarke zones A or B. User experience surveys were completed by 27 nurses and 46 patients. Most nurses found glucose management under the protocol effective (74%), easy to use (67%), and efficient (63%); 80% of nurses preferred inpatient CGM to FSBG. Most patients liked the CGM protocol (63%), reported positive CGM interactions with nursing staff (63%), and felt no significant interruptions to their diabetes management (63%). CONCLUSIONS Implementation of a hospital-wide inpatient CGM policy supporting multiple CGM types with real-time accuracy monitoring and integration into the EHR is feasible. Initial feedback from nurses and patients was favorable, and further investigation toward broader use and sustainability is needed.
Collapse
Affiliation(s)
- Ming Yeh Lee
- Division of Pediatric Endocrinology, Department of Pediatrics, Stanford University, Stanford, CA
| | - Susan M. Seav
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA
| | - Loice Ongwela
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA
| | - Julie J. Lee
- Department of Pediatrics, Stanford University School of Medicine, Stanford, CA
| | - Rachel Aubyrn
- Department of Inpatient Systems and Services, Stanford Health Care, Stanford, CA
| | - Fang Y. Cao
- Department of Medicine, Stanford University, Stanford, CA
| | - Anna Kalinsky
- Department of Inpatient Systems and Services, Stanford Health Care, Stanford, CA
| | | | - Yunzi Gu
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA
| | - Kailee Kingston
- Division of Pediatric Endocrinology, Department of Pediatrics, Stanford University, Stanford, CA
| | - Maja Ivanovic
- Department of Medicine, Stanford University, Stanford, CA
| | - Bruce A. Buckingham
- Division of Pediatric Endocrinology, Department of Pediatrics, Stanford University, Stanford, CA
| | - Dimpi Desai
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA
| | - Rayhan A. Lal
- Division of Pediatric Endocrinology, Department of Pediatrics, Stanford University, Stanford, CA
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA
| | - Marilyn Tan
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA
| | - Marina Basina
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA
| | - Michael S. Hughes
- Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University, Stanford, CA
| |
Collapse
|
9
|
Zhang Y, Yin X, Liu T, Ji W, Wang G. Association between the stress hyperglycemia ratio and mortality in patients with acute ischemic stroke. Sci Rep 2024; 14:20962. [PMID: 39251650 PMCID: PMC11385565 DOI: 10.1038/s41598-024-71778-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Accepted: 08/30/2024] [Indexed: 09/11/2024] Open
Abstract
The stress hyperglycemia ratio (SHR) is established as a reliable marker for assessing the severity of stress-induced hyperglycemia. While its effectiveness in managing patients with Acute Ischemic Stroke (AIS) remains to be fully understood. We aim to explore the relationship between SHR and clinical prognosis in AIS patients and to assess how diabetes status influences this relationship. In this study, we analyzed data from the Medical Information Mart for Intensive Care (MIMIC-IV) database, selecting patients with AIS who required ICU admission. These patients were categorized into tertiles based on their SHR levels. We applied Cox hazard regression models and used restricted cubic spline (RCS) curves to investigate relationships between outcomes and SHR. The study enrolled a total of 2029 patients. Cox regression demonstrated that a strong correlation was found between increasing SHR levels and higher all-cause mortality. Patients in the higher two tertiles of SHR experienced significantly elevated 30-day and 90-day mortality rates compared to those in the lowest tertile. This pattern remained consistent regardless of diabetes status. Further, RCS analysis confirmed a progressively increasing risk of all-cause mortality with higher SHR levels. The findings indicate that SHR is association with increased 30-day and 90-day mortality among AIS patients, underscoring its potential value in risk stratification. Although the presence of diabetes may weaken this association, significant correlations persist in diabetic patients.
Collapse
Affiliation(s)
- Yaxin Zhang
- Department of Neurology, Xiamen Humanity Hospital, Fujian Medical University, Xiamen, 361009, Fujian, China
| | - Xinxin Yin
- Department of Neurology, Xiamen Humanity Hospital, Fujian Medical University, Xiamen, 361009, Fujian, China
| | - Tingting Liu
- Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Xi'an Jiaotong University, NO.277 YanTa West Road, Xi'an, 710061, Shanxi, China
| | - Wenwen Ji
- Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Xi'an Jiaotong University, NO.277 YanTa West Road, Xi'an, 710061, Shanxi, China
| | - Guangdong Wang
- Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Xi'an Jiaotong University, NO.277 YanTa West Road, Xi'an, 710061, Shanxi, China.
| |
Collapse
|
10
|
Pal AD. Continuous Glucose Monitoring in Acutely and Critically Ill Patients. J Perianesth Nurs 2024; 39:684-685. [PMID: 39095120 DOI: 10.1016/j.jopan.2024.05.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Accepted: 05/21/2024] [Indexed: 08/04/2024]
Affiliation(s)
- Angela D Pal
- College of Nursing, University of Colorado Anschutz Medical Campus, Aurora, CO.
| |
Collapse
|
11
|
Honarmand K, Sirimaturos M, Hirshberg EL, Bircher NG, Agus MSD, Carpenter DL, Downs CR, Farrington EA, Freire AX, Grow A, Irving SY, Krinsley JS, Lanspa MJ, Long MT, Nagpal D, Preiser JC, Srinivasan V, Umpierrez GE, Jacobi J. Society of Critical Care Medicine Guidelines on Glycemic Control for Critically Ill Children and Adults 2024. Crit Care Med 2024; 52:e161-e181. [PMID: 38240484 DOI: 10.1097/ccm.0000000000006174] [Citation(s) in RCA: 30] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2024]
Abstract
RATIONALE Maintaining glycemic control of critically ill patients may impact outcomes such as survival, infection, and neuromuscular recovery, but there is equipoise on the target blood levels, monitoring frequency, and methods. OBJECTIVES The purpose was to update the 2012 Society of Critical Care Medicine and American College of Critical Care Medicine (ACCM) guidelines with a new systematic review of the literature and provide actionable guidance for clinicians. PANEL DESIGN The total multiprofessional task force of 22, consisting of clinicians and patient/family advocates, and a methodologist applied the processes described in the ACCM guidelines standard operating procedure manual to develop evidence-based recommendations in alignment with the Grading of Recommendations Assessment, Development, and Evaluation Approach (GRADE) methodology. Conflict of interest policies were strictly followed in all phases of the guidelines, including panel selection and voting. METHODS We conducted a systematic review for each Population, Intervention, Comparator, and Outcomes question related to glycemic management in critically ill children (≥ 42 wk old adjusted gestational age to 18 yr old) and adults, including triggers for initiation of insulin therapy, route of administration, monitoring frequency, role of an explicit decision support tool for protocol maintenance, and methodology for glucose testing. We identified the best available evidence, statistically summarized the evidence, and then assessed the quality of evidence using the GRADE approach. We used the evidence-to-decision framework to formulate recommendations as strong or weak or as a good practice statement. In addition, "In our practice" statements were included when the available evidence was insufficient to support a recommendation, but the panel felt that describing their practice patterns may be appropriate. Additional topics were identified for future research. RESULTS This guideline is an update of the guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients. It is intended for adult and pediatric practitioners to reassess current practices and direct research into areas with inadequate literature. The panel issued seven statements related to glycemic control in unselected adults (two good practice statements, four conditional recommendations, one research statement) and seven statements for pediatric patients (two good practice statements, one strong recommendation, one conditional recommendation, two "In our practice" statements, and one research statement), with additional detail on specific subset populations where available. CONCLUSIONS The guidelines panel achieved consensus for adults and children regarding a preference for an insulin infusion for the acute management of hyperglycemia with titration guided by an explicit clinical decision support tool and frequent (≤ 1 hr) monitoring intervals during glycemic instability to minimize hypoglycemia and against targeting intensive glucose levels. These recommendations are intended for consideration within the framework of the patient's existing clinical status. Further research is required to evaluate the role of individualized glycemic targets, continuous glucose monitoring systems, explicit decision support tools, and standardized glycemic control metrics.
Collapse
Affiliation(s)
- Kimia Honarmand
- Division of Critical Care, Department of Medicine, Mackenzie Health, Vaughan, ON, Canada
- GUIDE Canada, McMaster University, Hamilton, ON, Canada
| | - Michael Sirimaturos
- System Critical Care Pharmacy Services Leader, Houston Methodist Hospital, Houston, TX
| | - Eliotte L Hirshberg
- Adult and Pediatric Critical Care Specialist, University of Utah School of Medicine, Salt Lake City, UT
| | - Nicholas G Bircher
- Department of Nurse Anesthesia, School of Nursing, University of Pittsburgh, Pittsburgh, PA
| | - Michael S D Agus
- Harvard Medical School and Division Chief, Medical Critical Care, Boston Children's Hospital, Boston, MA
| | | | | | | | - Amado X Freire
- Pulmonary Critical Care and Sleep Medicine at the University of Tennessee Health Science Center, Memphis, TN
| | | | - Sharon Y Irving
- Department of Nursing and Clinical Care Services-Critical Care, University of Pennsylvania School of Nursing, Children's Hospital of Philadelphia, Philadelphia, PA
| | - James S Krinsley
- Director of Critical Care, Emeritus, Vagelos Columbia University College of Physicians and Surgeons, Stamford Hospital, Stamford, CT
| | - Michael J Lanspa
- Division of Critical Care, Intermountain Medical Center, Salt Lake City, UT
| | - Micah T Long
- Department of Anesthesiology, Division of Critical Care, University of Wisconsin School of Medicine & Public Health, Madison, WI
| | - David Nagpal
- Division of Cardiac Surgery, Critical Care Western, London Health Sciences Centre, London, ON, Canada
| | - Jean-Charles Preiser
- Medical Director for Research and Teaching, Erasme Hospital, Hôpital Universitaire de Bruxelles, Brussels, Belgium
| | - Vijay Srinivasan
- Departments of Anesthesiology, Critical Care and Pediatrics, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA
| | | | | |
Collapse
|
12
|
Loy SL, Ku CW, Zheng RT, Lim CHF, Chang TY, Chen LW, Cheung YB, Godfrey KM, Tan KH, Chong MFF, Chan JKY, Lek N, Yap F. Associations of predominant night-eating with plasma glycemic status and continuous glucose monitoring measures among pregnant women. Clin Nutr 2023; 42:2320-2327. [PMID: 37856921 DOI: 10.1016/j.clnu.2023.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 10/05/2023] [Accepted: 10/06/2023] [Indexed: 10/21/2023]
Abstract
BACKGROUND & AIMS To examine whether predominant night-eating, defined as more than 50% of total daily energy intake consumed between 1900 and 0659 h, is associated with glycemic outcomes in pregnancy. METHODS This was a prospective cohort study of 277 healthy pregnant women with complete 4-day dietary intake records at 18-24 weeks gestation, recruited from KK Women's and Children's Hospital, Singapore. Primary outcomes were fasting, 1-h, and 2-h plasma glucose after a 75-g oral glucose tolerance test at 24-28 weeks gestation. Secondary outcomes were gestational diabetes mellitus (GDM), fasting insulin, homeostasis model assessment of insulin resistance (HOMA2-IR), β-cell function (HOMA2-%B), and continuous glucose monitoring (CGM) measures. Glucose variables in continuous form were loge-transformed before analyses. RESULTS Predominant night-eating (11.6%) was associated with higher fasting glucose (geometric mean ratio (95% confidence interval) 1.05 (1.01, 1.08)) and 1-h glucose (1.11 (1.01, 1.21)), but not with 2-h glucose or GDM risk. Predominant night-eating women had lower fasting insulin (0.77 (0.63, 0.95)), lower HOMA2-IR (0.78 (0.64, 0.97)), and lower HOMA2-%B (0.77 (0.67, 0.89)) than their predominant day-eating counterparts. For CGM measures, predominant night-eating was associated with higher mean glucose (1.07 (1.00, 1.15)), higher glucose management indicator (1.05 (1.00, 1.10)), and higher overall glucose levels throughout 24 h (1.10 (1.02, 1.19)). All these associations were adjusted for socio-demographic, lifestyle factors, and diet composition. CONCLUSION Predominant night-eating was mainly associated with less desirable glycemic outcomes during pregnancy. Future studies should explore dietary interventions aimed at reducing consumption of relatively more calories at night than day during pregnancy.
Collapse
Affiliation(s)
- See Ling Loy
- Department of Reproductive Medicine, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229899, Singapore; Duke-NUS Medical School, 8 College Road, Singapore 169857, Singapore.
| | - Chee Wai Ku
- Department of Reproductive Medicine, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229899, Singapore; Duke-NUS Medical School, 8 College Road, Singapore 169857, Singapore
| | - Ruther Teo Zheng
- Endocrinology Service, Department of Pediatrics, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229899, Singapore
| | - Celeste Hong Fei Lim
- Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore
| | - Ting Yu Chang
- Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore
| | - Ling-Wei Chen
- Institute of Epidemiology and Preventive Medicine, College of Public Health, National Taiwan University, No. 17 Xu-Zhou Road, Taipei 10055, Taiwan; Master of Public Health Program, College of Public Health, National Taiwan University, No. 17 Xu-Zhou Road, Taipei 10055, Taiwan
| | - Yin Bun Cheung
- Program in Health Services & Systems Research, Duke-NUS Medical School, 8 College Road, Singapore 169857, Singapore; Tampere Centre for Child, Adolescent and Maternal Health Research, Tampere University, Tampere 33014, Finland
| | - Keith M Godfrey
- Medical Research Council Lifecourse Epidemiology Centre, University of Southampton, Southampton SO16 6YD, United Kingdom; National Institute for Health Research Southampton Biomedical Research Centre, University of Southampton and University Hospital Southampton National Health Service Foundation Trust, Southampton SO16 6YD, United Kingdom
| | - Kok Hian Tan
- Duke-NUS Medical School, 8 College Road, Singapore 169857, Singapore; Department of Maternal Fetal Medicine, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229899, Singapore
| | - Mary Foong-Fong Chong
- Saw Swee Hock School of Public Health, National University of Singapore, 12 Science Drive 2, Singapore 117549, Singapore; Singapore Institute for Clinical Sciences, Agency for Science, Technology and Research (A∗STAR), 30 Medical Drive, Singapore 117609, Singapore
| | - Jerry Kok Yen Chan
- Department of Reproductive Medicine, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229899, Singapore; Duke-NUS Medical School, 8 College Road, Singapore 169857, Singapore
| | - Ngee Lek
- Duke-NUS Medical School, 8 College Road, Singapore 169857, Singapore; Endocrinology Service, Department of Pediatrics, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229899, Singapore; Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore; Lee Kong Chian School of Medicine, Nanyang Technological University, 59 Nanyang Drive, Experimental Medicine Building, Singapore 636921, Singapore
| | - Fabian Yap
- Duke-NUS Medical School, 8 College Road, Singapore 169857, Singapore; Endocrinology Service, Department of Pediatrics, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229899, Singapore; Lee Kong Chian School of Medicine, Nanyang Technological University, 59 Nanyang Drive, Experimental Medicine Building, Singapore 636921, Singapore
| |
Collapse
|