1
|
Wang C, Duan L, Yang B, Ye Z, Yu J, Liu J, Zheng X, Yang Q, Jing G, Liu W, Li W, Liu W. Quantitative Determination of Volatile N-Nitrosamines in Meat Products Using Gas Chromatography Coupled to an Ion Mobility Spectrometer with an Ammonia Dopant. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:24101-24108. [PMID: 39417298 DOI: 10.1021/acs.jafc.4c07826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2024]
Abstract
Herein, we develop a novel method using gas chromatography-ion mobility spectrometry (IMS) with an ammonia dopant for the determination of volatile N-nitrosamines in meat products. The IMS system was implemented with Fourier deconvolution multiplexing to simultaneously improve the resolving power and sensitivity. The ammonia dopant mitigated the formation of N-nitrosamine dimer ions, suppressing the ionization of interferents and shifting the reactant peak from hydrated protons to hydrated ammonium ions. The ammonium adduct product ions of N-nitrosamines were confirmed using time-of-flight mass spectrometry. The instrument limits of detection and quantitation for nitrosamines were 0.78-1.79 and 2.60-5.82 ng/mL, respectively, with recoveries between 71.39% and 110.59% using a simple water distillation method. The developed method showed satisfactory performance when applied to the detection of nitrosamines in various meat products.
Collapse
Affiliation(s)
- Cheng Wang
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Lian Duan
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Binwang Yang
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Zhixiong Ye
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Jianna Yu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Jiaxu Liu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Xiuqin Zheng
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Qi Yang
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Guoxin Jing
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Wen Liu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Wenshan Li
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| | - Wenjie Liu
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, China
| |
Collapse
|
2
|
Boillat MA, Rakus JM, Hauser PC. Electrospray Ion Mobility Spectrometer Based on Flexible Printed-Circuit Board Electrodes with Improved Resolving Power. Anal Chem 2023. [PMID: 37407429 DOI: 10.1021/acs.analchem.3c01898] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/07/2023]
Abstract
An easily built drift tube instrument with ring electrodes made of rolled-up flexible printed circuit boards is reported. Its resolving power was maximized by careful attention to the drift tube geometry and the response time of the detector amplifier and by employing a high separation field strength. The separation of singly charged aliphatic quaternary ammonium ions introduced by electrospray was performed, and the measured resolving power was between 86 and 97% of the theoretical limit for three different drift tube lengths investigated. For the longest drift length of 30 cm, a resolving power of up to 228 was obtained. Three benzalkonium chlorides were also separated with resolving powers of over 210. The tristate injection scheme can also be used, with only a small loss of the separation performance compared to the two-state injection.
Collapse
Affiliation(s)
- Marc-Aurèle Boillat
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland
| | - Julian M Rakus
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland
| | - Peter C Hauser
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland
| |
Collapse
|
3
|
Smith CD, Giordano BC. Opioid cutting agents for use as internal standards in ion mobility spectrometry (IMS). Talanta 2023; 265:124822. [PMID: 37364383 DOI: 10.1016/j.talanta.2023.124822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 05/16/2023] [Accepted: 06/13/2023] [Indexed: 06/28/2023]
Abstract
Opioids have become a serious public health concern over the last decade. These compounds are commonly found mixed, or cut, with safer compounds to make the opioids appear unadulterated while also enhancing the psychoactive effect on the user. Commercial benchtop and handheld IMS devices are capable of detection but published reduced ion mobility (K0) values, used to identify the target analytes with IMS instrumentation, have shown variability. This lack of agreement, even for compounds used for calibration, is often due to the effects of drift tube temperature, drift gas water vapor levels and the use in-house built instrumentation rather than commercial equipment. Multiple reports exist on assessment of IMS reference standards but a single, consensus universal standard does not exist. Assessment of opioid cutting agents as internal standards is a worthwhile pursuit if precise and accurate K0 values are obtained. The effects of drift gas water vapor content and drift tube temperature were used to evaluate the cutting agents. The K0 values of papaverine, a representative opioid with a similar K0 value to heroin and fentanyl, were calculated with respect to quinine and were in agreement with literature data. The use of quinine as an internal standard also improved precision relative to the instrument standard and shows promise in the application presented here.
Collapse
Affiliation(s)
- Charles D Smith
- U.S. Naval Research Laboratory, 4555 Overlook Ave SW, Washington, D.C, 20375, United States
| | - Braden C Giordano
- U.S. Naval Research Laboratory, 4555 Overlook Ave SW, Washington, D.C, 20375, United States.
| |
Collapse
|
4
|
Bai X, Liu S, Huang W, Wang W, Li D, Wang A, Chen Y, Zhang Y, Cang H, Li H. Real-time monitoring of atmospheric ammonia based on modifier-enhanced vacuum ultraviolet photoionization ion mobility spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:2191-2198. [PMID: 37114921 DOI: 10.1039/d3ay00257h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Ammonia (NH3) plays an important role in the atmospheric environment such as the formation of PM2.5, the concentration monitoring of which could hence help in the air quality assessment. In this study, a method for quantitative monitoring of atmospheric NH3 was developed based on modifier-enhanced selectivity detection using a homemade vacuum ultraviolet photoionization ion mobility spectrometry (VUV-PI-IMS). To enhance the resolution and sensitivity of measuring NH3, 2-butanone as the gas modifier was introduced into the drift tube with the drift gas. Atmospheric NH3 can be selectively detected, where the peak-to-peak resolution (RP-P) of 7.69 was obtained. The product ions were identified to be [C4H8O]2NH4+ by using a homemade time-of-flight mass spectrometer. The calculated limit of detection (LOD) was 0.39 ppbv improving about 10 times. For the most common concentration variation of atmospheric NH3 in the range of 10-100 ppbv, the linear curve was obtained with R2 of 0.997. Lastly, the VUV-PI-IMS was used to monitor the evolution of atmospheric NH3 near our laboratory and mounted on a car for monitoring the regional distribution of atmospheric NH3 in Dalian, China. The results also showed that VUV-PI-IMS has a promising application prospect in monitoring the concentration of atmospheric NH3 and supporting the air quality assessment.
Collapse
Affiliation(s)
- Xueying Bai
- Dalian Jiaotong University, School of Materials Science and Engineering, Dalian 116028, China.
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Shimin Liu
- Dalian Jiaotong University, School of Materials Science and Engineering, Dalian 116028, China.
| | - Wei Huang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Weiguo Wang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Dongming Li
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Aibo Wang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Yi Chen
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Yuanzhi Zhang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Huaiwen Cang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Haiyang Li
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| |
Collapse
|
5
|
Kołacz AM, Wiśnik-Sawka M, Maziejuk M, Natora M, Harmata W, Rytel P, Gajda D. Air Pollution and Radiation Monitoring in Collective Protection Facilities. SENSORS (BASEL, SWITZERLAND) 2023; 23:706. [PMID: 36679500 PMCID: PMC9860701 DOI: 10.3390/s23020706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/16/2022] [Accepted: 01/05/2023] [Indexed: 06/17/2023]
Abstract
It has become increasingly important to monitor environment contamination by such chemicals as chemical warfare agents (CWAs) and industrial toxic chemicals (TICs), as well as radiation hazards around and inside collective protection facilities. This is especially important given the increased risk of terrorist or military attacks. The Military Institute of Chemistry and Radiometry (MICR) has constructed and developed the ALERT device for the effective monitoring of these threats. This device uses sensors that detect chemical and radiological contaminations in the air. The CWA detector is an ion mobility spectrometer, TICs are detected by electrochemical sensors, and radiation hazards are detected via Geiger-Muller tubes. The system was designed to protect the crew from contamination. When chemical or radioactive contamination is detected at the air inlet for the shelter, air filtration through a carbon filter is activated. At this time, the air test procedure at the filter outlet is started to test the condition of the filter on an ongoing basis. After detecting contamination at the filter outlet, the system turns off the air pumping and the service can start the procedure of replacing the damaged carbon filter. This paper presents the results of laboratory testing of the ALERT gas alarm detector, which showed high measurements for important parameters, including sensitivity, repeatability, accuracy, and speed.
Collapse
Affiliation(s)
- Angelika Monika Kołacz
- Military Institute of Chemistry and Radiometry, al. gen. A. Chruściela “Montera” 105, 00-910 Warsaw, Poland
| | - Monika Wiśnik-Sawka
- Military Institute of Chemistry and Radiometry, al. gen. A. Chruściela “Montera” 105, 00-910 Warsaw, Poland
- Faculty of Advanced Technologies and Chemistry, Military University of Technology, ul. gen. S. Kaliskiego 2, 00-908 Warsaw, Poland
| | - Mirosław Maziejuk
- Military Institute of Chemistry and Radiometry, al. gen. A. Chruściela “Montera” 105, 00-910 Warsaw, Poland
| | - Marek Natora
- Military Institute of Chemistry and Radiometry, al. gen. A. Chruściela “Montera” 105, 00-910 Warsaw, Poland
| | - Władyslaw Harmata
- Faculty of Advanced Technologies and Chemistry, Military University of Technology, ul. gen. S. Kaliskiego 2, 00-908 Warsaw, Poland
| | - Paweł Rytel
- Military Institute of Chemistry and Radiometry, al. gen. A. Chruściela “Montera” 105, 00-910 Warsaw, Poland
| | - Dorota Gajda
- Military Institute of Chemistry and Radiometry, al. gen. A. Chruściela “Montera” 105, 00-910 Warsaw, Poland
| |
Collapse
|
6
|
Moura PC, Vassilenko V. Gas Chromatography - Ion Mobility Spectrometry as a tool for quick detection of hazardous volatile organic compounds in indoor and ambient air: A university campus case study. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2022; 28:113-126. [PMID: 36200142 PMCID: PMC9647320 DOI: 10.1177/14690667221130170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 09/16/2022] [Indexed: 06/16/2023]
Abstract
Society's concerns about the citizens' exposure to possibly dangerous environments have recently risen; nevertheless, the assessment of indoor air quality still represents a major contemporary challenge. The volatile organic compounds (VOCs) are among the main factors responsible for deteriorating air quality conditions. These analytes are very common in daily-use environments and they can be extremely hazardous to human health, even at trace concentrations levels. For these reasons, their quick detection, identification, and quantification are crucial tasks, especially for indoor and heavily-populated scenarios, where the exposure time is usually quite long. In this work, a Gas Chromatography - Ion Mobility Spectrometry (GC-IMS) device was used for continuous monitoring indoor and ambient air environments at a large-scale, due to its outstanding levels of sensibility, selectivity, analytical flexibility, and almost real-time monitoring capability. A total of 496 spectra were collected from 15 locations of a university campus and posteriorly analysed. Overall, 23 compounds were identified among the 31 detected. Some of them, like Ethanol and 2-Propanol, were reported as being very hazardous to the human organism, especially in indoor environments. The achieved results confirmed the suitability of GC-IMS technology for air quality assessment and monitoring of VOCs and, more importantly, proved how dangerous indoor environments can be in scenarios of continuous exposure.
Collapse
Affiliation(s)
- Pedro Catalão Moura
- Laboratory for Instrumentation, Biomedical Engineering and Radiation
Physics (LibPhys-UNL), NOVA School of Science and
Technology, NOVA University of Lisbon, Caparica, Portugal
| | - Valentina Vassilenko
- Laboratory for Instrumentation, Biomedical Engineering and Radiation
Physics (LibPhys-UNL), NOVA School of Science and
Technology, NOVA University of Lisbon, Caparica, Portugal
- NMT, S. A., Caparica, Portugal
| |
Collapse
|
7
|
Chantipmanee N, Hauser PC. Determination of tobramycin in eye drops with an open-source hardware ion mobility spectrometer. Anal Bioanal Chem 2022; 414:4059-4066. [PMID: 35381854 PMCID: PMC9124657 DOI: 10.1007/s00216-022-04050-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 03/25/2022] [Accepted: 03/28/2022] [Indexed: 11/28/2022]
Abstract
The analysis of tobramycin was demonstrated successfully as an example for electrospray ionization on an open-source hardware ion mobility spectrometer. This instrument was assembled inexpensively in-house, and required only very few purpose-made components. The quantitative determination of tobramycin required 20 s for a reading. The calibration curve for the range from 50 to 200 μM was found to be linear with a correlation coefficient of r = 0.9994. A good reproducibility was obtained (3% relative standard deviation) and the limit of detection was determined as 8 μM. As the concentration of the active ingredient in the eye drops (ophthalmic solutions) is too high for the sensitivity of the instrument, the samples had to be diluted appropriately.
Collapse
Affiliation(s)
- Nattapong Chantipmanee
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056, Basel, Switzerland
| | - Peter C Hauser
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056, Basel, Switzerland.
| |
Collapse
|
8
|
Chantipmanee N, Furter JS, Hauser PC. Ambient ionization source based on a dielectric barrier discharge for direct testing of pharmaceuticals using ion mobility spectrometry. Anal Chim Acta 2022; 1195:339432. [DOI: 10.1016/j.aca.2022.339432] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/23/2021] [Accepted: 01/02/2022] [Indexed: 11/25/2022]
|
9
|
Capitain C, Weller P. Non-Targeted Screening Approaches for Profiling of Volatile Organic Compounds Based on Gas Chromatography-Ion Mobility Spectroscopy (GC-IMS) and Machine Learning. Molecules 2021; 26:molecules26185457. [PMID: 34576928 PMCID: PMC8468721 DOI: 10.3390/molecules26185457] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 08/30/2021] [Accepted: 09/01/2021] [Indexed: 12/20/2022] Open
Abstract
Due to its high sensitivity and resolving power, gas chromatography-ion mobility spectrometry (GC-IMS) is a powerful technique for the separation and sensitive detection of volatile organic compounds. It is a robust and easy-to-handle technique, which has recently gained attention for non-targeted screening (NTS) approaches. In this article, the general working principles of GC-IMS are presented. Next, the workflow for NTS using GC-IMS is described, including data acquisition, data processing and model building, model interpretation and complementary data analysis. A detailed overview of recent studies for NTS using GC-IMS is included, including several examples which have demonstrated GC-IMS to be an effective technique for various classification and quantification tasks. Lastly, a comparison of targeted and non-targeted strategies using GC-IMS are provided, highlighting the potential of GC-IMS in combination with NTS.
Collapse
|
10
|
Detection of Triacetone Triperoxide (TATP) and Hexamethylene Triperoxide Diamine (HMTD) from the Gas Phase with Differential Ion Mobility Spectrometry (DMS). SENSORS 2021; 21:s21134545. [PMID: 34283071 PMCID: PMC8272047 DOI: 10.3390/s21134545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 06/29/2021] [Accepted: 06/29/2021] [Indexed: 11/16/2022]
Abstract
One of the significant problems in the modern world is the detection of improvised explosives made of materials synthesized at home. Such compounds include triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD). An attempt was made to construct an instrument allowing for the simultaneous detection of both compounds despite the large difference of vapor pressure: very high for TATP and very low for HMTD. The developed system uses differential ion mobility spectrometry (DMS) in combination with a specially designed gas sample injection system. The created system of detectors allowed for the detection of a high concentration of TATP and a very low concentration of HMTD. TATP detection was possible despite the presence of impurities—acetone remaining from the technological process and formed as a coproduct of diacetone diperoxide (DADP) synthesis. Ammonia added to the carrier gas improved the possibility of detecting the abovementioned explosives, reducing the intensity of the acetone signal. The obtained results were then compared with the detection capabilities of drift tube ion mobility spectrometer (DT-IMS), which has not made possible such detection as DMS.
Collapse
|
11
|
Latif M, Zhang D, Gamez G. Flowing atmospheric-pressure afterglow drift tube ion mobility spectrometry. Anal Chim Acta 2021; 1163:338507. [PMID: 34024423 DOI: 10.1016/j.aca.2021.338507] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/29/2021] [Accepted: 04/06/2021] [Indexed: 10/21/2022]
Abstract
In this work, the flowing atmospheric-pressure afterglow (FAPA) ambient desorption/ionization source has been coupled with stand-alone Drift Tube Ion Mobility Spectrometry (DTIMS) for the first time. A tip repeller electrode, modified to allow higher bias potential still below the Townsend's breakdown, was implemented at the FAPA/DTIMS interface to overcome the opposing potentials and facilitate ion transmission. The effect of the lab-built DTIMS and FAPA's operating conditions (such as plasma voltage, current, gas flow rate, repeller's potential and positioning, FAPA orientation, etc.) on the signal of selected analytes was studied, for both gas-phase injection and desorption. The FAPA reactant ion peak (RIP) reduced mobility coefficient (K0) corresponds to protonated water clusters (H2O)nH+. The FAPA-DTIMS spectra of several selected compounds showed that their K0 agrees with literature values. Moreover, quantitative characterization of acetaminophen and 2,6-di-tert-butylpyridine (2,6-DTBP) based on desorption or gas-phase injection yield limits of detection (LODs) of 0.03 μg and 18 ppb, respectively.
Collapse
Affiliation(s)
- Mohsen Latif
- Department of Chemistry and Biochemistry, Texas Tech University, TX, 79409-1061, Lubbock, USA
| | - Dong Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, TX, 79409-1061, Lubbock, USA
| | - Gerardo Gamez
- Department of Chemistry and Biochemistry, Texas Tech University, TX, 79409-1061, Lubbock, USA.
| |
Collapse
|
12
|
Usage considerations for headspace-gas chromatography-ion mobility spectrometry as a suitable technique for qualitative analysis in a routine lab. J Chromatogr A 2021; 1640:461937. [PMID: 33556680 DOI: 10.1016/j.chroma.2021.461937] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 01/04/2021] [Accepted: 01/20/2021] [Indexed: 01/25/2023]
Abstract
The potential of headspace-gas chromatography-ion mobility spectrometry (HS-GC-IMS) to perform non-targeted qualitative analysis of complex samples has led to an unprecedented increase in its popularity in recent years. The operating principle of IMS makes quality control essential to ensure adequate results. Besides this, the suitability of GC-IMS is determined by multiple phenomena that take place before and during IMS detection. The present work discusses a novel GC-IMS quality control protocol for both beginners and experienced users. Likewise, it describes factors that must be taken into account in order to develop a robust GC-IMS qualitative analysis method and, if needed, to achieve the identification of VOCs present in real samples. The developed quality control protocol was successfully employed in our laboratory for the routine analysis of >500 real samples (olive oil and Iberian ham) for 6 months, thus it is recommended for the analysis of a great number of complex samples. Furthermore, the behaviour of the ions produced in the ionisation chamber and the possible reactions between them in GC-IMS qualitative analysis were assessed.
Collapse
|
13
|
Lebedev AV. Pyridine and Methylpyridines: Calculations of the Structure, Proton Affinity, Gas-Phase Basicity, and Mobility of Protonated Molecules and Proton-Bound Dimers. JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1134/s1061934820130079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
14
|
Hauck BC, Harden CS, McHugh VM. Accurate Evaluation of Potential Calibration Standards for Ion Mobility Spectrometry. Anal Chem 2020; 92:6158-6165. [PMID: 32233428 DOI: 10.1021/acs.analchem.0c00859] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Ion mobility spectrometry (IMS)-based instruments have historically been accurate to, at best, ±2% of the reduced ion mobility (K0) value of the chemical of interest. Fielded IMS-based detectors that are in use for hazardous and illicit substance detection are subject to false-positive alarms because of this inaccuracy and the resulting wide alarm windows, which are required to maintain a high rate of true-positive alarms. To reduce false-positive alarm rates and improve the accuracy of any IMS-based instrument, accurate K0 values of an ion mobility reference standard need to be used for ion mobility scale calibration. However, a suitable calibrant has yet to be accurately analyzed and agreed upon by the IMS community. In this study, we have chosen five potential IMS calibrants on the basis of their rating against seven criteria for suitable standards and analyzed them as a function of drift gas temperature and humidity using an accurate ion mobility instrument. Recommendations are made herein for each potential calibrant's suitability as a standard for the wider IMS community.
Collapse
Affiliation(s)
- Brian C Hauck
- Science and Technology Corporation (STC) - Support to CCDC CBC, 111 C Bata Blvd., Belcamp, Maryland 21017, United States
| | - Charles S Harden
- Science and Technology Corporation (STC) - Support to CCDC CBC, 111 C Bata Blvd., Belcamp, Maryland 21017, United States
| | - Vincent M McHugh
- U.S. Army Combat Capabilities Development Command Chemical Biological Center (CCDC CBC), Aberdeen Proving Ground, Maryland 21010, United States
| |
Collapse
|
15
|
Forbes TP, Lawrence J, Verkouteren JR, Verkouteren RM. Discriminative potential of ion mobility spectrometry for the detection of fentanyl and fentanyl analogues relative to confounding environmental interferents. Analyst 2019; 144:6391-6403. [PMID: 31579898 PMCID: PMC7008973 DOI: 10.1039/c9an01771b] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The opioid crisis and emergence of fentanyl, fentanyl analogues, and other synthetic opioids has highlighted the need for sensitive and robust detection for interdiction at screening points, notably vehicles at border crossings and packages at postal facilities. This work investigates the discriminative potential, sensitivity and specificity, of ion mobility spectrometry (IMS) for the detection of fentanyl and fifteen (15) fentanyl-related compounds (analogues, other opioids, and metabolites) relative to confounding environmental interferents. The environmental background interferent levels, frequency and intensity, were derived from over 10 000 screening samples collected from delivery vehicles entering a federal site. A receiver operating characteristic (ROC) curve methodology was employed to quantify the relationship between sensitivity and specificity for these target compounds on two instruments/configurations. These instrument configurations differed in desorption and drift tube temperatures, reactant ion dopant chemistry, and analysis time. This work identified reduced mobility areas of high interference that resulted in increased false positive rates (FPR), effectively reducing sensitivity (true positive rate: TPR) in those regions. Except for a few target compounds on either of the instruments that exhibited elevated FPRs, detection of fentanyl and fentanyl-related species was achieved at single to tens of nanograms with ≥90% TPR and ≤2% FPR. This work established the importance of systematic environmental background characterization at each specific screening setting in evaluating a platform's true performance.
Collapse
Affiliation(s)
- Thomas P Forbes
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD, USA.
| | | | | | | |
Collapse
|
16
|
Gabelica V, Shvartsburg AA, Afonso C, Barran P, Benesch JL, Bleiholder C, Bowers MT, Bilbao A, Bush MF, Campbell JL, Campuzano ID, Causon T, Clowers BH, Creaser CS, De Pauw E, Far J, Fernandez‐Lima F, Fjeldsted JC, Giles K, Groessl M, Hogan CJ, Hann S, Kim HI, Kurulugama RT, May JC, McLean JA, Pagel K, Richardson K, Ridgeway ME, Rosu F, Sobott F, Thalassinos K, Valentine SJ, Wyttenbach T. Recommendations for reporting ion mobility Mass Spectrometry measurements. MASS SPECTROMETRY REVIEWS 2019; 38:291-320. [PMID: 30707468 PMCID: PMC6618043 DOI: 10.1002/mas.21585] [Citation(s) in RCA: 325] [Impact Index Per Article: 54.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 11/01/2018] [Accepted: 11/02/2018] [Indexed: 05/02/2023]
Abstract
Here we present a guide to ion mobility mass spectrometry experiments, which covers both linear and nonlinear methods: what is measured, how the measurements are done, and how to report the results, including the uncertainties of mobility and collision cross section values. The guide aims to clarify some possibly confusing concepts, and the reporting recommendations should help researchers, authors and reviewers to contribute comprehensive reports, so that the ion mobility data can be reused more confidently. Starting from the concept of the definition of the measurand, we emphasize that (i) mobility values (K0 ) depend intrinsically on ion structure, the nature of the bath gas, temperature, and E/N; (ii) ion mobility does not measure molecular surfaces directly, but collision cross section (CCS) values are derived from mobility values using a physical model; (iii) methods relying on calibration are empirical (and thus may provide method-dependent results) only if the gas nature, temperature or E/N cannot match those of the primary method. Our analysis highlights the urgency of a community effort toward establishing primary standards and reference materials for ion mobility, and provides recommendations to do so. © 2019 The Authors. Mass Spectrometry Reviews Published by Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Valérie Gabelica
- University of Bordeaux, INSERM and CNRS, ARNA Laboratory, IECB site2 rue Robert Escarpit, 33600PessacFrance
| | | | | | - Perdita Barran
- Michael Barber Centre for Collaborative Mass SpectrometryManchester Institute for Biotechnology, University of ManchesterManchesterUK
| | - Justin L.P. Benesch
- Department of Chemistry, Chemistry Research LaboratoryUniversity of Oxford, Mansfield Road, OX1 3TAOxfordUK
| | - Christian Bleiholder
- Department of Chemistry and BiochemistryFlorida State UniversityTallahasseeFlorida32311
| | | | - Aivett Bilbao
- Biological Sciences DivisionPacific Northwest National LaboratoryRichlandWashington
| | - Matthew F. Bush
- Department of ChemistryUniversity of WashingtonSeattleWashington
| | | | | | - Tim Causon
- University of Natural Resources and Life Sciences (BOKU)Department of Chemistry, Division of Analytical ChemistryViennaAustria
| | - Brian H. Clowers
- Department of ChemistryWashington State UniversityPullmanWashington
| | - Colin S. Creaser
- Centre for Analytical ScienceDepartment of Chemistry, Loughborough UniversityLoughboroughUK
| | - Edwin De Pauw
- Laboratoire de spectrométrie de masse (L.S.M.) − Molecular SystemsUniversité de LiègeLiègeBelgium
| | - Johann Far
- Laboratoire de spectrométrie de masse (L.S.M.) − Molecular SystemsUniversité de LiègeLiègeBelgium
| | | | | | | | - Michael Groessl
- Department of Nephrology and Hypertension and Department of BioMedical ResearchInselspital, Bern University Hospital, University of Bern, Switzerland and TofwerkThunSwitzerland
| | | | - Stephan Hann
- University of Natural Resources and Life Sciences (BOKU)Department of Chemistry, Division of Analytical ChemistryViennaAustria
| | - Hugh I. Kim
- Department of ChemistryKorea UniversitySeoulKorea
| | | | - Jody C. May
- Department of ChemistryCenter for Innovative Technology, Vanderbilt UniversityNashvilleTennessee
| | - John A. McLean
- Department of ChemistryCenter for Innovative Technology, Vanderbilt UniversityNashvilleTennessee
| | - Kevin Pagel
- Freie Universitaet BerlinInstitute for Chemistry and BiochemistryBerlinGermany
| | | | | | - Frédéric Rosu
- CNRS, INSERM and University of BordeauxInstitut Européen de Chimie et BiologiePessacFrance
| | - Frank Sobott
- Antwerp UniversityBiomolecular & Analytical Mass SpectrometryAntwerpBelgium
- Astbury Centre for Structural Molecular BiologyUniversity of LeedsLeedsUK
- School of Molecular and Cellular BiologyUniversity of LeedsLeedsUK
| | - Konstantinos Thalassinos
- Institute of Structural and Molecular Biology, Division of BiosciencesUniversity College LondonLondonWC1E 6BTUK
- United Kingdom and Institute of Structural and Molecular BiologyDepartment of Biological Sciences, Birkbeck College, University of LondonLondonWC1E 7HXUK
| | - Stephen J. Valentine
- C. Eugene Bennett Department of ChemistryWest Virginia UniversityMorgantownWest Virginia
| | | |
Collapse
|
17
|
Seto Y, Hashimoto R, Taniguchi T, Ohrui Y, Nagoya T, Iwamatsu T, Komaru S, Usui D, Morimoto S, Sakamoto Y, Ishizaki A, Nishide T, Inoue Y, Sugiyama H, Nakano N. Development of Ion Mobility Spectrometry with Novel Atmospheric Electron Emission Ionization for Field Detection of Gaseous and Blister Chemical Warfare Agents. Anal Chem 2019; 91:5403-5414. [PMID: 30920801 DOI: 10.1021/acs.analchem.9b00672] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Drift tube ion mobility spectrometry with a novel atmospheric electron emission (AEE) source was developed for determination of gaseous and blister chemical warfare agents (CWAs) in negative mode. The AEE source was fabricated from an aluminum substrate electrode covered with 1 μm silver nanoparticle-dispersed silicone resin and a thin gold layer. This structure enabled stable tunneling electron emission upon the application of more than 11 V potential under atmospheric pressure. The reactant ion peak (RIP) was observed for the reduced mobility constant ( K0) of 2.18 and optimized at the charging voltage of 20 V. This RIP was assigned to O2- by using a mass spectrometer. Hydrogen cyanide was detected as a peak ( K0 = 2.47) that was discriminatively separated from the RIP (resolution = 1.4), with a limit of detection (LOD) of 0.057 mg/m3, and assigned to CN- and OCN-. Phosgene was detected as a peak ( K0 = 2.36; resolution = 1.2; and LOD = 0.6 mg/m3), which was assigned to Cl-. Lewisite 1 was detected as two peaks ( K0 = 1.68 and 1.34; LOD = 12 and 15 mg/m3). The K0 = 1.68 peak was ascribed to a mixture of adducts of molecules or the product of hydrolysis with oxygen or chloride. Cyanogen chloride, chlorine, and sulfur mustard were also well detected. The detection performance with the AEE source was compared with those under corona discharge and 63Ni ionizations. The advantage of the AEE source is the simple RIP pattern (only O2-), and the characteristic marker ions contribute to the discriminative CWAs detection.
Collapse
Affiliation(s)
- Yasuo Seto
- National Research Institute of Police Science , 6-3-1 Kashiwanoha , Kashiwa , Chiba 277-0882 , Japan
| | - Ryota Hashimoto
- National Research Institute of Police Science , 6-3-1 Kashiwanoha , Kashiwa , Chiba 277-0882 , Japan
| | - Takashi Taniguchi
- National Research Institute of Police Science , 6-3-1 Kashiwanoha , Kashiwa , Chiba 277-0882 , Japan
| | - Yasuhiko Ohrui
- National Research Institute of Police Science , 6-3-1 Kashiwanoha , Kashiwa , Chiba 277-0882 , Japan
| | - Tomoki Nagoya
- National Research Institute of Police Science , 6-3-1 Kashiwanoha , Kashiwa , Chiba 277-0882 , Japan
| | - Tadashi Iwamatsu
- Business Solutions BU, Advanced Technology Development Unit , Sharp Corporation , 492 Minosho-cho , Yamatokoriyama , Nara 639-1186 , Japan
| | - Shohei Komaru
- Business Solutions BU, Advanced Technology Development Unit , Sharp Corporation , 492 Minosho-cho , Yamatokoriyama , Nara 639-1186 , Japan
| | - Daisuke Usui
- Business Solutions BU, Advanced Technology Development Unit , Sharp Corporation , 492 Minosho-cho , Yamatokoriyama , Nara 639-1186 , Japan
| | - Satoshi Morimoto
- Business Solutions BU, Advanced Technology Development Unit , Sharp Corporation , 492 Minosho-cho , Yamatokoriyama , Nara 639-1186 , Japan
| | - Yasuhiro Sakamoto
- Business Solutions BU, Advanced Technology Development Unit , Sharp Corporation , 492 Minosho-cho , Yamatokoriyama , Nara 639-1186 , Japan
| | - Atsushi Ishizaki
- RIKEN KEIKI Co., Ltd. , 2-7-6 Azusawa , Itabashi, Tokyo 174-8744 , Japan
| | - Tatsuhiro Nishide
- RIKEN KEIKI Co., Ltd. , 2-7-6 Azusawa , Itabashi, Tokyo 174-8744 , Japan
| | - Yoko Inoue
- RIKEN KEIKI Co., Ltd. , 2-7-6 Azusawa , Itabashi, Tokyo 174-8744 , Japan
| | - Hiroaki Sugiyama
- RIKEN KEIKI Co., Ltd. , 2-7-6 Azusawa , Itabashi, Tokyo 174-8744 , Japan
| | - Nobuo Nakano
- RIKEN KEIKI Co., Ltd. , 2-7-6 Azusawa , Itabashi, Tokyo 174-8744 , Japan
| |
Collapse
|
18
|
Lim D, Davidson KL, Son S, Ahmed A, Bush MF, Kim S. Determining Collision Cross‐Sections of Aromatic Compounds in Crude Oil by Using Aromatic Compound Mixture as Calibration Standard. B KOREAN CHEM SOC 2018. [DOI: 10.1002/bkcs.11653] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Dongwan Lim
- Department of ChemistryKyungpook National University Daegu 41566 Republic of Korea
| | | | - Seungwoo Son
- Department of ChemistryKyungpook National University Daegu 41566 Republic of Korea
| | - Arif Ahmed
- Department of ChemistryKyungpook National University Daegu 41566 Republic of Korea
| | - Matthew F. Bush
- Department of ChemistryUniversity of Washington Seattle WA, 98195‐1700 USA
| | - Sunghwan Kim
- Department of ChemistryKyungpook National University Daegu 41566 Republic of Korea
- Green‐Nano Materials Research Center Daegu 41566 Republic of Korea
| |
Collapse
|
19
|
Hauck BC, Harden CS, McHugh VM. Current status and need for standards in ion mobility spectrometry. ACTA ACUST UNITED AC 2018. [DOI: 10.1007/s12127-018-0239-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
20
|
Fernandez-Maestre R. Buffer gas additives (modifiers/shift reagents) in ion mobility spectrometry: Applications, predictions of mobility shifts, and influence of interaction energy and structure. JOURNAL OF MASS SPECTROMETRY : JMS 2018; 53:598-613. [PMID: 29689602 DOI: 10.1002/jms.4190] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 03/24/2018] [Accepted: 04/07/2018] [Indexed: 06/08/2023]
Abstract
Ion mobility spectrometry (IMS) is an analytical technique used for fast and sensitive detection of illegal substances in customs and airports, diagnosis of diseases through detection of metabolites in breath, fundamental studies in physics and chemistry, space exploration, and many more applications. Ion mobility spectrometry separates ions in the gas-phase drifting under an electric field according to their size to charge ratio. Ion mobility spectrometry disadvantages are false positives that delay transportation, compromise patient's health and other negative issues when IMS is used for detection. To prevent false positives, IMS measures the ion mobilities in 2 different conditions, in pure buffer gas or when shift reagents (SRs) are introduced in this gas, providing 2 different characteristic properties of the ion and increasing the chances of right identification. Mobility shifts with the introduction of SRs in the buffer gas are due to clustering of analyte ions with SRs. Effective SRs are polar volatile compounds with free electron pairs with a tendency to form clusters with the analyte ion. Formation of clusters is favored by formation of stable analyte ion-SR hydrogen bonds, high analytes' proton affinity, and low steric hindrance in the ion charge while stabilization of ion charge by resonance may disfavor it. Inductive effects and the number of adduction sites also affect cluster formation. The prediction of IMS separations of overlapping peaks is important because it simplifies a trial and error procedure. Doping experiments to simplify IMS spectra by changing the ion-analyte reactions forming the so-called alternative reactant ions are not considered in this review and techniques other than drift tube IMS are marginally covered.
Collapse
|
21
|
Lim D, Ahmed A, Kim S. Comparison of Theoretical Calculation Methods for Obtaining Collisional Cross-Section of Aromatic Compounds. B KOREAN CHEM SOC 2018. [DOI: 10.1002/bkcs.11501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Dongwan Lim
- Kyungpook National University; Department of Chemistry; Daegu 41566 Republic of Korea
| | - Arif Ahmed
- Kyungpook National University; Department of Chemistry; Daegu 41566 Republic of Korea
| | - Sunghwan Kim
- Kyungpook National University; Department of Chemistry; Daegu 41566 Republic of Korea
- Green Nano Center; Department of Chemistry; Daegu 41566 Republic of Korea
| |
Collapse
|
22
|
Ewing RG, Valenzuela BR. Selective Reagent Ions for the Direct Vapor Detection of Organophosphorus Compounds Below Parts-per-Trillion Levels. Anal Chem 2018; 90:7583-7590. [PMID: 29812936 DOI: 10.1021/acs.analchem.8b01265] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Real-time low to sub parts-per-trillion (pptv) vapor detection of some organophosphorous compounds (OPCs) is demonstrated with an atmospheric flow tube-mass spectrometer. The chemical species investigated included dimethyl methylphosphonate, triethyl phosphate, and tributylphosphate. The atmospheric flow tube provides ambient chemical ionization with up to several seconds of ionization time. With sensitivities in the parts-per-quadrillion (ppqv) range, there are many background contaminants competing for charge with the target analytes. Initially, the OPCs were not observable in direct room air analysis, presumably due to other trace components possessing higher proton affinities. However, the addition of a trialkylamine as a dopant chemical served to provide a single reagent ion that also formed a proton-bound heterodimer with the OPCs. These asymmetric proton-bound dimers had sufficiently high hydrogen bond energy to allow the cluster to remain intact during the analysis time of several seconds. Changes in stability were observed for some of these asymmetric proton-bound dimers with a shorter half-life for adducts with a larger proton affinity differences between the amine and the OPC. Detection levels approaching low pptv to high ppqv were correlated by three different methods, including use of a permeation tube, direct injection of a fixed mass into the sample air flow, and calculations based upon signal intensity ratios, reaction time, and an estimated reaction rate constant. A practical demonstration showed real-time monitoring of a laboratory environment initially with low pptv levels of vapor observed to decay exponentially over about an hour while returning to baseline levels.
Collapse
Affiliation(s)
- Robert G Ewing
- Pacific Northwest National Laboratory , 902 Battelle Blvd. , Richland , Washington 99352 , United States
| | - Blandina R Valenzuela
- Pacific Northwest National Laboratory , 902 Battelle Blvd. , Richland , Washington 99352 , United States
| |
Collapse
|
23
|
Sorribes-Soriano A, de la Guardia M, Esteve-Turrillas FA, Armenta S. Trace analysis by ion mobility spectrometry: From conventional to smart sample preconcentration methods. A review. Anal Chim Acta 2018; 1026:37-50. [PMID: 29852992 DOI: 10.1016/j.aca.2018.03.059] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Revised: 03/26/2018] [Accepted: 03/27/2018] [Indexed: 12/17/2022]
Abstract
Ion mobility spectrometry (IMS) is a rapid and high sensitive technique widely used in security and forensic areas. However, a lack of selectivity is usually observed in the analysis of complex samples due to the scarce resolution of the technique. The literature concerning the use of conventional and novel smart materials in the pretreatment and preconcentration of samples previous to IMS determinations has been critically reviewed. The most relevant strategies to enhance selectivity and sensitivity of IMS determinations have been widely discussed, based in the use of smart materials, as immunosorbents, aptamers, molecularly imprinted polymers (MIPs), ionic liquids (ILs) and nanomaterial. The observed trend is focused on the development of IMS analytical methods in combination of selective sample treatments in order to achieve quick, reliable, sensitive, and selective methods for the analysis of complex samples such as biological fluids, food, or environmental samples.
Collapse
Affiliation(s)
- A Sorribes-Soriano
- Analytical Chemistry Department, University of Valencia, 50(th) Dr. Moliner St., 46100, Burjassot, Spain
| | - M de la Guardia
- Analytical Chemistry Department, University of Valencia, 50(th) Dr. Moliner St., 46100, Burjassot, Spain
| | - F A Esteve-Turrillas
- Analytical Chemistry Department, University of Valencia, 50(th) Dr. Moliner St., 46100, Burjassot, Spain
| | - S Armenta
- Analytical Chemistry Department, University of Valencia, 50(th) Dr. Moliner St., 46100, Burjassot, Spain.
| |
Collapse
|
24
|
Du Z, Sun T, Zhao J, Wang D, Zhang Z, Yu W. Development of a plug-type IMS-MS instrument and its applications in resolving problems existing in in-situ detection of illicit drugs and explosives by IMS. Talanta 2018; 184:65-72. [PMID: 29674084 DOI: 10.1016/j.talanta.2018.02.086] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 12/12/2017] [Accepted: 02/21/2018] [Indexed: 10/17/2022]
Abstract
Ion mobility spectrometry (IMS) which acts as a rapid analysis technique is widely used in the field detection of illicit drugs and explosives. Due to limited separation abilities of the pint-sized IMS challenges and problems still exist regarding high false positive and false negative responses due to the interference of the matrix. In addition, the gas-phase ion chemistry and special phenomena in the IMS spectra, such one substance showing two peaks, were not identified unambiguously. In order to explain or resolve these questions, in this paper, an ion mobility spectrometry was coupled to a mass spectrometry (IMS-MS). A commercial IMS is embedded in a custom-built ion chamber shell was attached to the mass spectrometer. The faraday plate of IMS was fabricated with a hole for the ions to passing through to the mass spectrometer. The ion transmission efficiency of IMS-MS was optimized by optimizing the various parameters, especially the distance between the faraday plate and the cone of mass spectrum. This design keeps the integrity of the two original instruments and the mass spectrometry still works with multimode ionization source (i.e., IMS-MS, ESI-MS, APCI-MS modes). The illicit drugs and explosive samples were analyzed by the IMS-MS with 63Ni source. The results showed that the IMS-MS is of high sensitivity. The ionization mechanism of the illicit drug and explosive samples with 63Ni source were systematically studied. In addition, the interferent which interfered the detection of cocaine was identified as dibutyl phthalate (DBP) by this platform. The reason why the acetone solution of amphetamine showed two peaks was explained.
Collapse
Affiliation(s)
- Zhenxia Du
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China.
| | - Tangqiang Sun
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Jianan Zhao
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Di Wang
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | | | - Wenlian Yu
- Chinese Academy of Inspection and Quarantine, Beijing, China
| |
Collapse
|
25
|
Hauck BC, Siems WF, Harden CS, McHugh VM, Hill HH. High Accuracy Ion Mobility Spectrometry for Instrument Calibration. Anal Chem 2018. [DOI: 10.1021/acs.analchem.7b04987] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Brian C. Hauck
- Department of Chemistry, Washington State University, 305 Fulmer Hall, Pullman, Washington 99164, United States
| | - William F. Siems
- Department of Chemistry, Washington State University, 305 Fulmer Hall, Pullman, Washington 99164, United States
| | - Charles S. Harden
- LEIDOS—U.S. Army Edgewood Chemical Biological Center Operations, P.O. Box 68, Gunpowder, Maryland 21010, United States
| | - Vincent M. McHugh
- U.S. Army Edgewood Chemical Biological Center, Aberdeen Proving Ground, Maryland 21010, United States
| | - Herbert H. Hill
- Department of Chemistry, Washington State University, 305 Fulmer Hall, Pullman, Washington 99164, United States
| |
Collapse
|
26
|
Selectivity improvement of positive photoionization ion mobility spectrometry for rapid detection of organophosphorus pesticides by switching dopant concentration. Talanta 2018; 176:247-252. [DOI: 10.1016/j.talanta.2017.08.045] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 08/07/2017] [Accepted: 08/12/2017] [Indexed: 12/22/2022]
|
27
|
Hauck BC, Siems WF, Harden CS, McHugh VM, Hill HH. Construction and evaluation of a hermetically sealed accurate ion mobility instrument. ACTA ACUST UNITED AC 2017. [DOI: 10.1007/s12127-017-0224-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
28
|
Hollerbach A, Baird Z, Cooks RG. Ion Separation in Air Using a Three-Dimensional Printed Ion Mobility Spectrometer. Anal Chem 2017; 89:5058-5065. [PMID: 28383249 DOI: 10.1021/acs.analchem.7b00469] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Adam Hollerbach
- Chemistry
Department, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | | | - R. Graham Cooks
- Chemistry
Department, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| |
Collapse
|
29
|
Abstract
In this review, we focus on an important aspect of ion mobility (IM) research, namely the reporting of quantitative ion mobility measurements in the form of the gas-phase collision cross section (CCS), which has provided a common basis for comparison across different instrument platforms and offers a unique form of structural information, namely size and shape preferences of analytes in the absence of bulk solvent. This review surveys the over 24,000 CCS values reported from IM methods spanning the era between 1975 to 2015, which provides both a historical and analytical context for the contributions made thus far, as well as insight into the future directions that quantitative ion mobility measurements will have in the analytical sciences. The analysis was conducted in 2016, so CCS values reported in that year are purposely omitted. In another few years, a review of this scope will be intractable, as the number of CCS values which will be reported in the next three to five years is expected to exceed the total amount currently published in the literature.
Collapse
Affiliation(s)
- Jody C May
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - Caleb B Morris
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - John A McLean
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| |
Collapse
|
30
|
Mirzajani R, Ramezani Z, Kardani F. Selective determination of thidiazuron herbicide in fruit and vegetable samples using molecularly imprinted polymer fiber solid phase microextraction with ion mobility spectrometry detection (MIPF-SPME-IMS). Microchem J 2017. [DOI: 10.1016/j.microc.2016.08.009] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
31
|
Cheng S, Li H, Jiang D, Chen C, Zhang T, Li Y, Wang H, Zhou Q, Li H, Tan M. Sensitive detection of trimethylamine based on dopant-assisted positive photoionization ion mobility spectrometry. Talanta 2017; 162:398-402. [DOI: 10.1016/j.talanta.2016.10.056] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Revised: 10/10/2016] [Accepted: 10/12/2016] [Indexed: 10/20/2022]
|
32
|
Ion mobility spectrometry: Current status and application for chemical warfare agents detection. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.06.002] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
33
|
Waraksa E, Perycz U, Namieśnik J, Sillanpää M, Dymerski T, Wójtowicz M, Puton J. Dopants and gas modifiers in ion mobility spectrometry. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.06.009] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
34
|
Browne CA, Forbes TP, Sisco E. Detection and identification of sugar alcohol sweeteners by ion mobility spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2016; 8:5611-5618. [PMID: 27574530 PMCID: PMC4999899 DOI: 10.1039/c6ay01554a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The rapid and sensitive detection of sugar alcohol sweeteners was demonstrated using ion mobility spectrometry (IMS). IMS provides a valuable alternative in sensitivity, cost, and analysis speed between the lengthy gold-standard liquid chromatography-mass spectrometry (LC-MS) technique and rapid point-of-measurement disposable colorimetric sensors, for the Food and Nutrition industry's quality control and other "foodomics" area needs. The IMS response, characteristic signatures, and limits of detection for erythritol, pentaerythritol, xylitol, inositol, sorbitol, mannitol, and maltitol were evaluated using precise inkjet printed samples. IMS system parameters including desorption temperature, scan time, and swipe substrate material were examined and optimized, demonstrating a strong dependence on the physicochemical properties of the respective sugar alcohol. The desorption characteristics of each compound were found to dominate the system response and overall sensitivity. Sugar alcohol components of commercial products - chewing gum and a sweetener packet - were detected and identified using IMS. IMS is demonstrated to be an advantageous field deployable instrument, easily operated by non-technical personnel, and enabling sensitive point-of-measurement quality assurance for sugar alcohols.
Collapse
Affiliation(s)
| | - Thomas P. Forbes
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD, USA
| | - Edward Sisco
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD, USA
| |
Collapse
|
35
|
Forbes TP, Najarro M. Ion mobility spectrometry nuisance alarm threshold analysis for illicit narcotics based on environmental background and a ROC-curve approach. Analyst 2016; 141:4438-46. [PMID: 27206280 PMCID: PMC5054301 DOI: 10.1039/c6an00844e] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The discriminative potential of an ion mobility spectrometer (IMS) for trace detection of illicit narcotics relative to environmental background was investigated with a receiver operating characteristic (ROC) curve framework. The IMS response of cocaine, heroin, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), and Δ(9)-tetrahydro-cannabinol (THC) was evaluated against environmental background levels derived from the screening of incoming delivery vehicles at a federal facility. Over 20 000 samples were collected over a multiyear period under two distinct sets of instrument operating conditions, a baseline mode and an increased desorption/drift tube temperature and sampling time mode. ROC curves provided a quantifiable representation of the interplay between sensitivity (true positive rate, TPR) and specificity (1 - false positive rate, FPR). A TPR of 90% and minimized FPR were targeted as the detection limits of IMS for the selected narcotics. MDMA, THC, and cocaine demonstrated single nanogram sensitivity at 90% TPR and <10% FPR, with improvements to both MDMA and cocaine in the elevated temperature/increased sampling mode. Detection limits in the tens of nanograms with poor specificity (FPR ≈ 20%) were observed for methamphetamine and heroin under baseline conditions. However, elevating the temperature reduced the background in the methamphetamine window, drastically improving its response (90% TPR and 3.8% FPR at 1 ng). On the contrary, the altered mode conditions increased the level of background for THC and heroin, partially offsetting observed enhancements to desorption. The presented framework demonstrated the significant effect environmental background distributions have on sensitivity and specificity.
Collapse
Affiliation(s)
- Thomas P Forbes
- National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD, USA.
| | | |
Collapse
|
36
|
Hauck BC, Siems WF, Harden CS, McHugh VM, Hill HH. E/N effects on K0 values revealed by high precision measurements under low field conditions. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:075104. [PMID: 27475592 DOI: 10.1063/1.4955208] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Accepted: 06/21/2016] [Indexed: 06/06/2023]
Abstract
Ion mobility spectrometry (IMS) is used to detect chemical warfare agents, explosives, and narcotics. While IMS has a low rate of false positives, their occurrence causes the loss of time and money as the alarm is verified. Because numerous variables affect the reduced mobility (K0) of an ion, wide detection windows are required in order to ensure a low false negative response rate. Wide detection windows, however, reduce response selectivity, and interferents with similar K0 values may be mistaken for targeted compounds and trigger a false positive alarm. Detection windows could be narrowed if reference K0 values were accurately known for specific instrumental conditions. Unfortunately, there is a lack of confidence in the literature values due to discrepancies in the reported K0 values and their lack of reported error. This creates the need for the accurate control and measurement of each variable affecting ion mobility, as well as for a central accurate IMS database for reference and calibration. A new ion mobility spectrometer has been built that reduces the error of measurements affecting K0 by an order of magnitude less than ±0.2%. Precise measurements of ±0.002 cm(2) V(-1) s(-1) or better have been produced and, as a result, an unexpected relationship between K0 and the electric field to number density ratio (E/N) has been discovered in which the K0 values of ions decreased as a function of E/N along a second degree polynomial trend line towards an apparent asymptote at approximately 4 Td.
Collapse
Affiliation(s)
- Brian C Hauck
- Department of Chemistry, Washington State University, 305 Fulmer Hall, Pullman, Washington 99164, USA
| | - William F Siems
- Department of Chemistry, Washington State University, 305 Fulmer Hall, Pullman, Washington 99164, USA
| | - Charles S Harden
- LEIDOS, US Army ECBC Operations, P.O. Box 68, Gunpowder, Maryland 21010, USA
| | - Vincent M McHugh
- U.S. Army Edgewood Chemical Biological Center, Aberdeen Proving Ground, Maryland 21010, USA
| | - Herbert H Hill
- Department of Chemistry, Washington State University, 305 Fulmer Hall, Pullman, Washington 99164, USA
| |
Collapse
|
37
|
Szymańska E, Davies AN, Buydens LMC. Chemometrics for ion mobility spectrometry data: recent advances and future prospects. Analyst 2016; 141:5689-5708. [DOI: 10.1039/c6an01008c] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
This is the first comprehensive review on chemometric techniques used in ion mobility spectrometry data analysis.
Collapse
Affiliation(s)
- Ewa Szymańska
- Radboud University
- Institute for Molecules and Materials
- 6500 GL Nijmegen
- The Netherlands
- TI-COAST
| | - Antony N. Davies
- School of Applied Sciences
- Faculty of Computing
- Engineering and Science
- University of South Wales
- UK
| | | |
Collapse
|
38
|
Maziejuk M, Puton J, Szyposzyńska M, Witkiewicz Z. Fragmentation of molecular ions in differential mobility spectrometry as a method for identification of chemical warfare agents. Talanta 2015; 144:1201-6. [DOI: 10.1016/j.talanta.2015.07.039] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2015] [Revised: 07/04/2015] [Accepted: 07/12/2015] [Indexed: 10/23/2022]
|
39
|
Chen C, Tabrizchi M, Wang W, Li H. Field Switching Combined with Bradbury–Nielsen Gate for Ion Mobility Spectrometry. Anal Chem 2015; 87:7925-30. [DOI: 10.1021/acs.analchem.5b01737] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Chuang Chen
- Key
Laboratory of Separation Science for Analytical Chemistry, Dalian
Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People’s Republic of China
| | - Mahmoud Tabrizchi
- Department
of Chemistry, Isfahan University of Technology, Isfahan 84156-83111, Iran
| | - Weiguo Wang
- Key
Laboratory of Separation Science for Analytical Chemistry, Dalian
Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People’s Republic of China
| | - Haiyang Li
- Key
Laboratory of Separation Science for Analytical Chemistry, Dalian
Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People’s Republic of China
| |
Collapse
|
40
|
Kozole J, Levine LA, Tomlinson-Phillips J, Stairs JR. Gas phase ion chemistry of an ion mobility spectrometry based explosive trace detector elucidated by tandem mass spectrometry. Talanta 2015; 140:10-19. [PMID: 26048817 DOI: 10.1016/j.talanta.2015.03.001] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2014] [Revised: 03/01/2015] [Accepted: 03/02/2015] [Indexed: 11/26/2022]
Abstract
The gas phase ion chemistry for an ion mobility spectrometer (IMS) based explosive detector has been elucidated using tandem mass spectrometry. The IMS system, which is operated with hexachloroethane and isobutyramide reagent gases and an ion shutter type gating scheme, is connected to the atmospheric pressure interface of a triple quadrupole mass spectrometer (MS/MS). Product ion masses, daughter ion masses, and reduced mobility values for a collection of nitro, nitrate, and peroxide explosives measured with the IMS/MS/MS instrument are reported. The mass and mobility data together with targeted isotopic labeling experiments and information about sample composition and reaction environment are leveraged to propose molecular formulas, structures, and ionization pathways for the various product ions. The major product ions are identified as [DNT-H](-) for DNT, [TNT-H](-) for TNT, [RDX+Cl](-) and [RDX+NO2](-) for RDX, [HMX+Cl](-) and [HMX+NO2](-) for HMX, [NO3](-) for EGDN, [NG+Cl](-) and [NG+NO3](-) for NG, [PETN+Cl](-) and [PETN+NO3](-) for PETN, [HNO3+NO3](-) for NH4NO3, [NO2](-) for DMNB, [HMTD-NC3H6O3+H+Cl](-) and [HMTD+H-CH2O-H2O2](+) for HMTD, and [(CH3)3CO2](+) for TATP. In general, the product ions identified for the IMS system studied here are consistent with the product ions reported previously for an ion trap mobility spectrometer (ITMS) based explosive trace detector, which is operated with dichloromethane and ammonia reagent gases and an ion trap type gating scheme. Differences between the explosive trace detectors include the [NG+Cl](-) and [PETN+Cl](-) product ions being major ions in the IMS system compared to minor ions in the ITMS system as well as the major product ion for TATP being [(CH3)3CO2](+) for the IMS system and [(CH3)2CNH2](+) for the ITMS system.
Collapse
Affiliation(s)
- Joseph Kozole
- U.S. Department of Homeland Security, Science & Technology Directorate, Transportation Security Laboratory, Atlantic City International Airport, NJ, United States
| | - Lauren A Levine
- Kutztown University, Department of Physical Sciences, Kutztown, PA, United States
| | - Jill Tomlinson-Phillips
- U.S. Department of Homeland Security, Science & Technology Directorate, Transportation Security Laboratory, Atlantic City International Airport, NJ, United States
| | - Jason R Stairs
- U.S. Department of Homeland Security, Science & Technology Directorate, Transportation Security Laboratory, Atlantic City International Airport, NJ, United States.
| |
Collapse
|
41
|
Cumeras R, Figueras E, Davis CE, Baumbach JI, Gràcia I. Review on ion mobility spectrometry. Part 1: current instrumentation. Analyst 2015; 140:1376-90. [PMID: 25465076 PMCID: PMC4331213 DOI: 10.1039/c4an01100g] [Citation(s) in RCA: 295] [Impact Index Per Article: 29.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Ion Mobility Spectrometry (IMS) is a widely used and 'well-known' technique of ion separation in the gaseous phase based on the differences in ion mobilities under an electric field. All IMS instruments operate with an electric field that provides space separation, but some IMS instruments also operate with a drift gas flow that provides also a temporal separation. In this review we will summarize the current IMS instrumentation. IMS techniques have received an increased interest as new instrumentation and have become available to be coupled with mass spectrometry (MS). For each of the eight types of IMS instruments reviewed it is mentioned whether they can be hyphenated with MS and whether they are commercially available. Finally, out of the described devices, the six most-consolidated ones are compared. The current review article is followed by a companion review article which details the IMS hyphenated techniques (mainly gas chromatography and mass spectrometry) and the factors that make the data from an IMS device change as a function of device parameters and sampling conditions. These reviews will provide the reader with an insightful view of the main characteristics and aspects of the IMS technique.
Collapse
Affiliation(s)
- R Cumeras
- Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), Esfera UAB, Campus UAB s/n, E-08193 Bellaterra, Barcelona, Spain.
| | | | | | | | | |
Collapse
|
42
|
Cohen G, Rudnik DD, Laloush M, Yakir D, Karpas Z. A Novel Method for Determination of Histamine in Tuna Fish by Ion Mobility Spectrometry. FOOD ANAL METHOD 2015. [DOI: 10.1007/s12161-015-0129-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
43
|
Peng L, Hua L, Li E, Wang W, Zhou Q, Wang X, Wang C, Li J, Li H. Dopant titrating ion mobility spectrometry for trace exhaled nitric oxide detection. J Breath Res 2015; 9:016003. [PMID: 25557839 DOI: 10.1088/1752-7155/9/1/016003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Ion mobility spectrometry (IMS) is a promising non-invasive tool for the analysis of exhaled gas and exhaled nitric oxide (NO), a biomarker for diagnosis of respiratory diseases. However, the high moisture in exhaled gas always brings about extra overlapping ion peaks and results in poor identification ability. In this paper, p-benzoquinone (PBQ) was introduced into IMS to eliminate the interference of overlapping ion peaks and realize the selective identification of NO. The overlapping ions caused by moisture were titrated by PBQ and then converted to hydrated PBQ anions (C6H4[Formula: see text](H2O)n). The NO concentration could be determined by quantifying gas phase hydrated nitrite anions (N[Formula: see text](H2O)n), product ions of NO. Under optimized conditions, a limit of detection (LOD) of about 1.4 ppbv and a linear range of 10-200 ppbv were obtained for NO even in 100% relative humidity (RH) purified air. Furthermore, this established method was applied to measure hourly the exhaled NO of eight healthy volunteers, and real-time monitoring the exhaled NO of an esophageal carcinoma patient during radical surgery. These results revealed the potential of the current dopant titrating IMS method in the measurement of exhaled NO for medical disease diagnosis.
Collapse
Affiliation(s)
- Liying Peng
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, People's Republic of China. University of Chinese Academy of Sciences, Beijing, 100049, People's Republic of China
| | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Hill AR, Edgar M, Chatzigeorgiou M, Reynolds JC, Kelly PF, Creaser CS. Analysis of triacetone triperoxide complexes with alkali metal ions by electrospray and extractive electrospray ionisation combined with ion mobility spectrometry and mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2015; 21:265-274. [PMID: 26307706 DOI: 10.1255/ejms.1348] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The complexation of triacetone triperoxide (TATP) with a range of alkali metals has been studied by electrospray ionisation-mass spectrometry yield [M+Cat](+) ions for all of the alkali metals. The formation of [2TATP+Li+LiX](+) (X = Br, Cl) sandwich complexes was also observed. Collision cross- sections for the lithium-containing complexes of TATP were measured by travelling wave ion mobility spectrometry mass spectrometry, and compared well with computationally determined structures. Extractive electrospray ionisation (EESI) using a lithium doped electrospray is demonstrated for the detection of TATP vapours desorbed from a metal surface. The limit of detection for EESI was shown to be 20 ng using the [TATP+Li](+) ion.
Collapse
Affiliation(s)
- Alex R Hill
- Centr e for Analytical Science, Department of Chemistry, Loughborough University, Leicestershire, LE11 3TU, UK.
| | - Mark Edgar
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Leicestershire, LE11 3TU, UK.
| | - Maria Chatzigeorgiou
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Leicestershire, LE11 3TU, UK. m.chatzigeorgiou- 13@
| | - James C Reynolds
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Leicestershire, LE11 3TU, UK.
| | - Paul F Kelly
- Cent re for Analytical Science, Department of Chemistry, Loughborough University, Leicestershire, LE11 3TU, UK.
| | - Colin S Creaser
- C entre for Analytical Science, Department of Chemistry, Loughborough University, Leicestershire, LE11 3TU, UK.
| |
Collapse
|
45
|
Liuni P, Romanov V, Binette MJ, Zaknoun H, Tam M, Pilon P, Hendrikse J, Wilson DJ. Unambiguous Characterization of Analytical Markers in Complex, Seized Opiate Samples Using an Enhanced Ion Mobility Trace Detector-Mass Spectrometer. Anal Chem 2014; 86:10772-9. [DOI: 10.1021/ac502676d] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Peter Liuni
- Department
of Chemistry, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada
| | - Vladimir Romanov
- Smiths Detection,
Inc., 7030 Century Avenue, Mississauga, Ontario L5N 2V8, Canada
| | - Marie-Josée Binette
- Canada Border
Services Agency, 79 Bentley Avenue, Ottawa, Ontario K2E 6T7, Canada
| | - Hafid Zaknoun
- Canada Border
Services Agency, 79 Bentley Avenue, Ottawa, Ontario K2E 6T7, Canada
| | - Maggie Tam
- Canada Border
Services Agency, 79 Bentley Avenue, Ottawa, Ontario K2E 6T7, Canada
| | - Pierre Pilon
- Canada Border
Services Agency, 79 Bentley Avenue, Ottawa, Ontario K2E 6T7, Canada
| | - Jan Hendrikse
- Smiths Detection,
Inc., 7030 Century Avenue, Mississauga, Ontario L5N 2V8, Canada
| | - Derek J. Wilson
- Department
of Chemistry, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada
| |
Collapse
|
46
|
Keelor JD, Dwivedi P, Fernández FM. An effective approach for coupling direct analysis in real time with atmospheric pressure drift tube ion mobility spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:1538-1548. [PMID: 24903510 DOI: 10.1007/s13361-014-0926-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2014] [Revised: 05/06/2014] [Accepted: 05/06/2014] [Indexed: 06/03/2023]
Abstract
Drift tube ion mobility spectrometry (DTIMS) has evolved as a robust analytical platform routinely used for screening small molecules across a broad suite of chemistries ranging from food and pharmaceuticals to explosives and environmental toxins. Most modern atmospheric pressure IM detectors employ corona discharge, photoionization, radioactive, or electrospray ion sources for efficient ion production. Coupling standalone DTIMS with ambient plasma-based techniques, however, has proven to be an exceptional challenge. Device sensitivity with near-ground ambient plasma sources is hindered by poor ion transmission at the source-instrument interface, where ion repulsion is caused by the strong electric field barrier of the high potential ion mobility spectrometry (IMS) inlet. To overcome this shortfall, we introduce a new ion source design incorporating a repeller point electrode used to shape the electric field profile and enable ion transmission from a direct analysis in real time (DART) plasma ion source. Parameter space characterization studies of the DART DTIMS setup were performed to ascertain the optimal configuration for the source assembly favoring ion transport. Preliminary system capabilities for the direct screening of solid pharmaceuticals are briefly demonstrated.
Collapse
Affiliation(s)
- Joel D Keelor
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | | | | |
Collapse
|
47
|
Armenta S, Garrigues S, de la Guardia M, Brassier J, Alcalà M, Blanco M, Perez-Alfonso C, Galipienso N. Detection and characterization of emerging psychoactive substances by ion mobility spectrometry. Drug Test Anal 2014; 7:280-9. [DOI: 10.1002/dta.1678] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Revised: 03/20/2014] [Accepted: 05/05/2014] [Indexed: 11/07/2022]
Affiliation(s)
- Sergio Armenta
- Department of Analytical Chemistry, Research Building; University of Valencia; 50 Dr. Moliner St E-46100 Burjassot Valencia Spain
| | - Salvador Garrigues
- Department of Analytical Chemistry, Research Building; University of Valencia; 50 Dr. Moliner St E-46100 Burjassot Valencia Spain
| | - Miguel de la Guardia
- Department of Analytical Chemistry, Research Building; University of Valencia; 50 Dr. Moliner St E-46100 Burjassot Valencia Spain
| | - Judit Brassier
- Department of Chemistry, Faculty of Sciences; Universitat Autònoma de Barcelona; E-08193 Bellaterra Barcelona Spain
| | - Manel Alcalà
- Department of Chemistry, Faculty of Sciences; Universitat Autònoma de Barcelona; E-08193 Bellaterra Barcelona Spain
| | - Marcelo Blanco
- Department of Chemistry, Faculty of Sciences; Universitat Autònoma de Barcelona; E-08193 Bellaterra Barcelona Spain
| | - Clara Perez-Alfonso
- Unidad de Inspección de Farmacia y Control de Drogas del Área de Sanidad de Valencia; Muelle de la aduana s/n 46024 Valencia Spain
| | - Nieves Galipienso
- Unidad de Inspección de Farmacia y Control de Drogas del Área de Sanidad de Valencia; Muelle de la aduana s/n 46024 Valencia Spain
| |
Collapse
|
48
|
Holopainen S, Luukkonen V, Nousiainen M, Sillanpää M. Determination of chlorophenols in water by headspace solid phase microextraction ion mobility spectrometry (HS-SPME-IMS). Talanta 2013; 114:176-82. [DOI: 10.1016/j.talanta.2013.04.023] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Revised: 04/03/2013] [Accepted: 04/08/2013] [Indexed: 10/27/2022]
|
49
|
Comparison of reactant and analyte ions for 63Nickel, corona discharge, and secondary electrospray ionization sources with ion mobility-mass spectrometry. Talanta 2013; 107:225-32. [DOI: 10.1016/j.talanta.2013.01.009] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 01/08/2013] [Accepted: 01/08/2013] [Indexed: 11/19/2022]
|
50
|
Demoranville LT, Houssiau L, Gillen G. Behavior and Evaluation of Tetraalkylammonium Bromides as Instrument Test Materials in Thermal Desorption Ion Mobility Spectrometers. Anal Chem 2013; 85:2652-8. [DOI: 10.1021/ac302944m] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Leonard T. Demoranville
- Surface & Microanalysis Science Division, National Institute of Standards and Technology, MS-8371, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | - Laurent Houssiau
- Research Centre in Physics of
Matter and Radiation (PMR), Physics Department, University of Namur (FUNDP), 61 rue de Bruxelles, B 5000 Namur,
Belgium
| | - Greg Gillen
- Surface & Microanalysis Science Division, National Institute of Standards and Technology, MS-8371, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| |
Collapse
|