1
|
Arik N, Elcin E, Tezcaner A, Oktem HA. Biosensing of arsenic by whole-cell bacterial bioreporter immobilized on polycaprolactone (PCL) electrospun fiber. ENVIRONMENTAL TECHNOLOGY 2024; 45:4874-4886. [PMID: 37965791 DOI: 10.1080/09593330.2023.2283405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 09/19/2023] [Indexed: 11/16/2023]
Abstract
In recent years, heavy metals derived from several anthropogenic sources have both direct and indirect detrimental effects on the health of the environment and living organisms. Whole-cell bioreporters (WCBs) that can be used to monitor the levels of heavy metals in drinking and natural spring waters are important. In this study, whole-cell arsenic bacterial bioreporters were immobilized using polycaprolactone (PCL) electrospun fibers as the support material. The aim is to determine the properties of this immobilized bioreporter system by evaluating its performance in arsenic detection. Within the scope of the study, different growth media and fiber immobilization times were tested to determine the parameters affecting the fluorescent signals emitted by the immobilized bioreporter system in the presence of two dominant forms of arsenic, namely arsenite (As(III)) and arsenate (As(V)). In addition, the sensitivity, selectivity, response time, and shelf-life of the developed bioreporter system were evaluated. As far as the literature is concerned, this is the first study to investigate the potential of using PCL-electrospun fiber-immobilized fluorescent bacterial bioreporter for arsenic detection. This study will open new avenues in environmental arsenic monitoring.
Collapse
Affiliation(s)
- Nehir Arik
- Department of Molecular Biology and Genetics, Middle East Technical University, Ankara, Türkiye
| | - Evrim Elcin
- Department of Agricultural Biotechnology, Aydın Adnan Menderes University, Aydın, Türkiye
| | - Aysen Tezcaner
- Department of Engineering Sciences, Middle East Technical University, Ankara, Türkiye
- Center of Excellence in Biomaterials and Tissue Engineering (METU BIOMATEN), Ankara, Türkiye
| | - Huseyin A Oktem
- Department of Molecular Biology and Genetics, Middle East Technical University, Ankara, Türkiye
- Department of Biological Sciences, Middle East Technical University, Ankara, Türkiye
| |
Collapse
|
2
|
Yang M, Cao M, Zhang Z, Wang C. PCB-C 4D coupled with paper-based microfluidic sampling for the rapid detection of liquid conductivity. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2543-2555. [PMID: 38591249 DOI: 10.1039/d4ay00198b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
The detection of liquid electrical conductivity has board applications in food safety testing, water quality monitoring, and agricultural soil analysis. Electrodes used in traditional liquid electrical conductivity detection come into direct contact with liquid, leading to electrode contamination and affecting the accuracy of the detection results. The capacitively coupled contactless conductivity detection (C4D) method effectively addresses this issue. However, impurity particles present in the solution can compromise the consistency and repeatability of detection results. This study combines paper-based microfluidic technology with printed circuit board-capacitively coupled contactless conductivity detection (PCB-C4D) to address this issue. Prior to sample detection, in situ rapid filtration is employed to remove impurity particles from the raw solution sample, significantly enhancing detection consistency and reliability. Simultaneously, Optimization of PCB-C4D parameters, channel size, filtration time, and solution drop rate ensures optimal detection conditions. A compact kit design facilitates reliable assembly of the PCB-C4D electrodes and paper-based channel, enhancing practicality. Practical measurements on the conductivity of orange juice, cucumber, and soil solution further validate the method's accuracy, rapidity, and effectiveness in in situ conductivity detection. This work advances the practical application of PCB-C4D technology.
Collapse
Affiliation(s)
- Mingpeng Yang
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China.
- Jiangsu Collaborative Innovation Centre on Atmospheric Environment and Equipment Technology, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China
| | - Mingyi Cao
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China.
| | - Zhixuan Zhang
- China Aero Geophysical Survey and Remote Sensing Center for Natural Resources, 29 Xueyuan Road, Beijing 10083, China
| | - Chaofan Wang
- School of Automation, Nanjing University of Information Science and Technology, 219 Ningliu Road, Nanjing 210044, China.
| |
Collapse
|
3
|
Molavinia S, Moosavi M, Hejazi S, Azadnasab R, Mansouri E, Khodayar MJ. Metformin alleviates sodium arsenite-induced hepatotoxicity and glucose intolerance in mice by suppressing oxidative stress, inflammation, and apoptosis. J Trace Elem Med Biol 2023; 80:127299. [PMID: 37690370 DOI: 10.1016/j.jtemb.2023.127299] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 08/28/2023] [Accepted: 09/04/2023] [Indexed: 09/12/2023]
Abstract
BACKGROUND Epidemiological studies have shown that exposure to sodium arsenite (NaAsO2) causes diabetes and hepatotoxicity. Metformin (MET), an oral hypoglycemic agent, has long been used in diabetes therapy. In addition, MET has been shown to have hepatoprotective effects. In this study, we investigated the effects of MET on NaAsO2-induced hepatotoxicity and glucose intolerance in mice. METHODS Mice were divided into four groups: Groups I and II received distilled water and NaAsO2 (10 mg/kg, p.o.) for five weeks, respectively. Groups III and IV were treated with NaAsO2 (10 mg/kg, p.o.) for three weeks, followed by MET (125 and 250 mg/kg, p.o.) for the last two weeks before NaAsO2. A glucose tolerance test was performed on day 35. The serum and tissue parameters were also evaluated. RESULTS Histopathological examination revealed NaAsO2-induced liver and pancreatic damage. NaAsO2 caused hyperglycemia, glucose intolerance, and a significant increase in liver function enzymes. Administration of NaAsO2 significantly reduced hepatic superoxide dismutase, catalase, glutathione peroxidase, and total thiol levels and increased the content of reactive thiobarbituric acid substances. In addition, it led to an increase in liver nitric oxide levels and protein expression of tumor necrosis factor-α, nuclear factor kappa B, and cysteine-aspartic proteases-3. In contrast, treatment with MET (250 mg/kg) significantly improved NaAsO2-induced biochemical and histopathological changes. CONCLUSION Our findings suggest that the significant effects of MET against NaAsO2-induced hepatotoxicity and glucose intolerance may be exerted via the regulation of oxidative stress, followed by suppression of inflammation and apoptosis.
Collapse
Affiliation(s)
- Shahrzad Molavinia
- Toxicology Research Center, Medical Basic Sciences Research Institute, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Mehrnoosh Moosavi
- Toxicology Research Center, Medical Basic Sciences Research Institute, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; Department of Toxicology, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Sara Hejazi
- Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; Department of Toxicology, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Reza Azadnasab
- Toxicology Research Center, Medical Basic Sciences Research Institute, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Esrafil Mansouri
- Cellular and molecular research center, Medical Basic Sciences Research Institute, Department of Anatomical Sciences, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Mohammad Javad Khodayar
- Toxicology Research Center, Medical Basic Sciences Research Institute, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; Department of Toxicology, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
| |
Collapse
|
4
|
Hata N, Takahashi S, Osada S, Katagiri S, Naruse M, Igarashi A, Sazawa K, Taguchi S, Kuramitz H. In Situ Formation of a Relatively Transparent Ion-Associate Liquid Phase from an Aqueous Phase and Its Application to Microextraction/High-Performance Liquid Chromatography-Fluorescence Detection of Bisphenol A in Water. Molecules 2023; 28:7525. [PMID: 38005251 PMCID: PMC10673447 DOI: 10.3390/molecules28227525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 10/27/2023] [Accepted: 11/06/2023] [Indexed: 11/26/2023] Open
Abstract
The design of a simple approach enabling the detection of bisphenol A (BPA) in water samples without the need for large amounts of solvents is of utmost importance. This paper reports a simple method for the separation, concentration, and quantification of BPA in water samples using high-performance liquid chromatography with fluorescence detection (HPLC-FLD) after its microextraction into an in situ formed organic ion-associate (IA) liquid phase (LP). Novel IA phase components without conjugated double bonds, such as benzene rings, were investigated. Ethylhexyloxypropylamine hydrochloride and sodium dodecyl sulfate solutions were added to the water samples to form IAs. The aqueous phase and ion-associate liquid phase (IALP) were separated by centrifugation. The aqueous phase was removed, and the liquid phase was recovered and measured using HPLC-FLD or HPLC-electrochemical detection (ECD). The concentrated phase (IALP) had a relatively low viscosity and could be injected directly into the chromatograph without dissolving it in organic solvents. The detection limits for BPA by HPLC-FLD and HPLC-ECD were 0.009 and 0.3 µg L-1, respectively.
Collapse
Affiliation(s)
- Noriko Hata
- Major of Earth, Life and Environmental Science, Graduate School of Science and Engineering, University of Toyama, 3190 Gofuku, Toyama 930-8555, Japan (K.S.); (S.T.); (H.K.)
| | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Gregucci D, Nazir F, Calabretta MM, Michelini E. Illuminating Progress: The Contribution of Bioluminescence to Sustainable Development Goal 6-Clean Water and Sanitation-Of the United Nations 2030 Agenda. SENSORS (BASEL, SWITZERLAND) 2023; 23:7244. [PMID: 37631781 PMCID: PMC10458275 DOI: 10.3390/s23167244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/12/2023] [Accepted: 08/14/2023] [Indexed: 08/27/2023]
Abstract
The United Nations Agenda 2030 Sustainable Development Goal 6 (SDG 6) aims at ensuring the availability and sustainable management of water and sanitation. The routine monitoring of water contaminants requires accurate and rapid analytical techniques. Laboratory analyses and conventional methods of field sampling still require considerable labor and time with highly trained personnel and transport to a central facility with sophisticated equipment, which renders routine monitoring cumbersome, time-consuming, and costly. Moreover, these methods do not provide information about the actual toxicity of water, which is crucial for characterizing complex samples, such as urban wastewater and stormwater runoff. The unique properties of bioluminescence (BL) offer innovative approaches for developing advanced tools and technologies for holistic water monitoring. BL biosensors offer a promising solution by combining the natural BL phenomenon with cutting-edge technologies. This review provides an overview of the recent advances and significant contributions of BL to SDG 6, focusing attention on the potential use of the BL-based sensing platforms for advancing water management practices, protecting ecosystems, and ensuring the well-being of communities.
Collapse
Affiliation(s)
- Denise Gregucci
- Department of Chemistry “Giacomo Ciamician”, University of Bologna, Via Selmi 2, 40126 Bologna, Italy; (D.G.); (F.N.); (M.M.C.)
- Center for Applied Biomedical Research (CRBA), Azienda Ospedaliero-Universitaria Policlinico S. Orsola-Malpighi, 40138 Bologna, Italy
| | - Faisal Nazir
- Department of Chemistry “Giacomo Ciamician”, University of Bologna, Via Selmi 2, 40126 Bologna, Italy; (D.G.); (F.N.); (M.M.C.)
| | - Maria Maddalena Calabretta
- Department of Chemistry “Giacomo Ciamician”, University of Bologna, Via Selmi 2, 40126 Bologna, Italy; (D.G.); (F.N.); (M.M.C.)
- Center for Applied Biomedical Research (CRBA), Azienda Ospedaliero-Universitaria Policlinico S. Orsola-Malpighi, 40138 Bologna, Italy
| | - Elisa Michelini
- Department of Chemistry “Giacomo Ciamician”, University of Bologna, Via Selmi 2, 40126 Bologna, Italy; (D.G.); (F.N.); (M.M.C.)
- Center for Applied Biomedical Research (CRBA), Azienda Ospedaliero-Universitaria Policlinico S. Orsola-Malpighi, 40138 Bologna, Italy
- Health Sciences and Technologies Interdepartmental Center for Industrial Research (HSTICIR), University of Bologna, 40126 Bologna, Italy
| |
Collapse
|