1
|
Li X, Li H, Liang X, Chen Z, Zhang M, He Q, Zhou J, Feng Z, Liu Y, Chen X, Chen H, Ye Z, Huang Z, Zhang X, Zhang H, Chu LT, Guo W. Using Electroosmotic Pumps to Control the Flow Velocity in Cotton Thread-Based µTADs. Electrophoresis 2025. [PMID: 40347083 DOI: 10.1002/elps.8153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2025] [Revised: 04/09/2025] [Accepted: 04/28/2025] [Indexed: 05/12/2025]
Abstract
Flow velocity control is of great interest for passive microfluidic devices that are used in point-of-care diagnostics. Various methods have been developed for the flow velocity control of microfluidic paper-based analytical devices (µPADs), whereas fewer attempts have been made for microfluidic thread-based analytical devices (µTADs). In this research, we attempt to control the flow velocity in cotton thread-based µTADs with electroosmotic pumping. Utilizing electroosmotic pumps, the flow velocity in the cotton thread-based µTADs can be decreased or increased by 13% and 106%, respectively. Moreover, the dynamic control of the flow velocity in the cotton thread-based µTADs is achieved by adjusting the real-time magnitude and direction of the voltage. Furthermore, we demonstrate that electroosmotic pumps can be used to overcome the hydrophobic valves in the cotton thread-based µTADs. We show that the delivery sequence of different liquid samples for a three-branch µTAD can be controlled. Finally, we show the potential application in lithium detection with a colorimetric assay. This method for flow velocity control shows promise for customizing the flow velocity and reaction time of cotton thread-based µTADs, and this method can potentially increase the sensitivity of detection.
Collapse
Affiliation(s)
- Xionghui Li
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| | - Haonan Li
- Department of Electrical Engineering, Shantou University, Shantou, Guangdong, China
| | - Xuanying Liang
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| | - Zejingqiu Chen
- Department of Biology, Shantou University, Shantou, Guangdong, China
| | - Muyang Zhang
- Department of Electrical Engineering, Shantou University, Shantou, Guangdong, China
| | - Qinghao He
- Department of Electrical Engineering, Shantou University, Shantou, Guangdong, China
| | - Jie Zhou
- Department of Electrical Engineering, Shantou University, Shantou, Guangdong, China
| | - Zitao Feng
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| | - Yeqian Liu
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| | - Xinyi Chen
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| | - Huilin Chen
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| | - Zitong Ye
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| | - Ziwei Huang
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| | - Xingwei Zhang
- Department of Mechatronic Engineering, Shantou University, Shantou, Guangdong, China
| | - Huiru Zhang
- Guangdong Foshan Lianchuang Graduate School of Engineering, Foshan, Guangdong, China
| | - Lok Ting Chu
- Institute of Biochemistry and Molecular Biology, Guangdong Medical University, Zhanjiang, Guangdong, China
| | - Weijin Guo
- Department of Biomedical Engineering, Shantou University, Shantou, Guangdong, China
| |
Collapse
|
2
|
Nellaiappan S, Vishnu N, Manoj D, Kanagaraj T, Selvaraj M, Assiri MA. Electrochemical flow injection analysis platforms for biomedical applications - Progress and prospects. Anal Biochem 2025; 700:115795. [PMID: 39894143 DOI: 10.1016/j.ab.2025.115795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2024] [Revised: 01/27/2025] [Accepted: 01/28/2025] [Indexed: 02/04/2025]
Abstract
Flow injection analysis coupled with electrochemical detection (FIA-ECD) techniques has to be a key technological development for wide variety of applications in various domains such as synthetic analytical chemistry, materials science, biomedical and point-of-care devices. FIA-ECD techniques have to be unique due to decreasing the time of analysis, sample pre-treatment, reactions and separation-free detection for multi-analytes. In biomedical domain, various electrochemical sensors were decorated with bioactive molecules, i.e., DNA, antibodies, enzymes along with biocompatible polymers for the detection of biologically important chemicals and analytes. The flexibility and practical applicability of these sensors may serve as a new pattern for clinical and biomedical analytical instrumentations. This review covers the highlights and overview of the most successful and promising electrochemical sensors, biosensors and immunosensors integrated with the flow injection analysis platforms, fabrication and analytical parameters, pros and cons of these sensor technologies, challenges and future opportunities in point-of-care clinical analysis.
Collapse
Affiliation(s)
- Subramanian Nellaiappan
- Centre of Excellence for Energy Research, Centre for Nanoscience and Nanotechnology, Sathyabama Institute of Science and Technology, Chennai, 600119, Tamil Nadu, India.
| | - Nandimalla Vishnu
- Department of Chemistry, GITAM School of Science, GITAM Deemed to Be University, Hyderabad, Telangana, 502329, India
| | - Devaraj Manoj
- Department of Chemistry, Karpagam Academy of Higher Education, Coimbatore, 641 021, India; Centre for Material Chemistry, Karpagam Academy of Higher Education, Coimbatore, 641 021, India
| | - Thamaraiselvi Kanagaraj
- Department of Biomaterials, Saveetha Dental College and Hospital, SIMATS, Saveetha University, Chennai, 600 077, India; School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongbuk, 38541, Republic of Korea
| | - Manickam Selvaraj
- Department of Chemistry, Faculty of Science, King Khalid University, Abha, 61413, Saudi Arabia; Research Centre for Advanced Materials Science (RCAMS), King Khalid University, PO Box 9004, Abha, 61413, Saudi Arabia
| | - Mohammed A Assiri
- Department of Chemistry, Faculty of Science, King Khalid University, Abha, 61413, Saudi Arabia; Research Centre for Advanced Materials Science (RCAMS), King Khalid University, PO Box 9004, Abha, 61413, Saudi Arabia
| |
Collapse
|
3
|
de Moraes NC, Carvalho RM, Ferreira VS, da Silva RAB, de Melo EI, Petroni JM, Lucca BG. Improving the performance and versatility of microfluidic thread electroanalytical devices by automated injection with electronic pipettes: a new and powerful 3D-printed analytical platform. Mikrochim Acta 2023; 190:461. [PMID: 37926729 DOI: 10.1007/s00604-023-06026-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 09/29/2023] [Indexed: 11/07/2023]
Abstract
Microfluidic cotton thread-based electroanalytical devices (μTEDs) are analytical systems with attractive features such as spontaneous passive flow, low cost, minimal waste production, and good sensitivity. Currently, sample injection in µTEDs is performed by hand using manual micropipettes, which have drawbacks such as inconstant speed and position, dependence of skilled analysts, and need of physical effort of operator during prolonged times, leading to poor reproducibility and risk of strain injury. As an alternative to these inconveniences, we propose, for the first time, the use of electronic micropipettes to carry out automated injections in µTEDs. This new approach avoids all disadvantages of manual injections, while also improving the performance, experience, and versatility of µTEDs. The platform developed here is composed by three 3D-printed electrodes (detector) attached to a 3D-printed platform containing an adjustable holder that keeps the electronic pipette in the same x/y/z position. As a proof-of-concept, both injection modes (manual and electronic) were compared using three model analytes (nitrite, paracetamol, and 5-hydroxytryptophan) on µTED with amperometric detection. As result, improved analytical performance (limits of detection between 2.5- and 5-fold lower) was obtained when using electronic injections, as well as better repeatability/reproducibility and higher analytical frequencies. In addition, the determination of paracetamol in urine samples suggested better precision and accuracy for automated injection. Thus, electronic injection is a great advance and changes the state-of-art of µTEDs, mainly considering the use of more modern and versatile electronic pipettes (wider range of pre-programmed modes), which can lead to the development of even more automated systems.
Collapse
Affiliation(s)
- Natália Canhete de Moraes
- Institute of Chemistry, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil
| | - Rayan Marcel Carvalho
- Institute of Chemistry, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil
| | - Valdir Souza Ferreira
- Institute of Chemistry, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil
| | | | - Edmar Isaias de Melo
- Institute of Chemistry, Federal University of Uberlândia, Monte Carmelo, MG, 38500-000, Brazil
| | | | - Bruno Gabriel Lucca
- Institute of Chemistry, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil.
| |
Collapse
|
4
|
Dos Santos VW, Martins G, Gogola JL, Kalinke C, Agustini D, Bergamini MF, Marcolino-Junior LH. Simultaneous detection of dopamine and ascorbic acid by using a thread-based microfluidic device and multiple pulse amperometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:4862-4869. [PMID: 37702326 DOI: 10.1039/d3ay00693j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
This study presents a novel approach for the simultaneous detection of ascorbic acid (AA) and dopamine (DA) using an affordable and user-friendly microfluidic device. Microfluidic devices, when combined with electrochemical detectors like screen-printed electrodes (SPEs), offer numerous advantages such as portability, high sample throughput, and low reagent consumption. In this study, a 3D-printed microfluidic device called a μTED was developed, utilizing textile threads as microfluidic channels and an unmodified SPE as the amperometric detector. The method employed multiple pulse amperometry (MPA) with carefully selected potential values (+0.65 V and -0.10 V). The reduction current signals generated by dopamine o-quinone were used to calculate a correction factor for the oxidation signals of ascorbic acid, enabling simultaneous quantification. The developed microfluidic device ensured a stable flow rate of the carrier solution at 1.19 μL s-1, minimizing the consumption of samples and reagents (injection volume of 2.0 μL). Under the optimized experimental conditions, a linear range from 50 to 900 μmol L-1 was achieved for both DA and AA. The obtained sensitivities were 2.24 μA L mmol-1 for AA and 5.09 μA L mmol-1 for DA, with corresponding limits of detection (LOD) of 2.60 μmol L-1 and 1.54 μmol L-1, respectively. To confirm the effectiveness of the proposed method, it was successfully applied to analyze AA and DA in a commercial blood serum sample spiked at three different concentration levels, with a medium recovery rate of 70%. Furthermore, the MPA technique demonstrated its simplicity by enabling the simultaneous determination of AA and DA without the need for prior separation steps or the use of chemically modified electrodes.
Collapse
Affiliation(s)
- Vanessa W Dos Santos
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Gustavo Martins
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Jeferson L Gogola
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Cristiane Kalinke
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
- Institute of Chemistry, University of Campinas (UNICAMP), CEP 13083-859, Campinas, SP, Brazil
| | - Deonir Agustini
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Márcio F Bergamini
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Luiz H Marcolino-Junior
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| |
Collapse
|
5
|
Watanabe EY, Gevaerd A, Caetano FR, Marcolino-Junior LH, Bergamini MF. An electrochemical microfluidic device for non-enzymatic cholesterol determination using a lab-made disposable electrode. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023. [PMID: 37469272 DOI: 10.1039/d3ay00654a] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
Cholesterol is an important steroid and hormone precursor, and its levels in the blood are associated with risk factors for cardiovascular diseases. In this work, a non-enzymatic methodology for cholesterol determination in serum samples is described. First, a working electrode was constructed using homemade ink and a plastic substrate by a simple dunking process. Next, the dunked electrode (DWE) was modified with nickel ions (Ni-DWE) and combined with a low-cost microfluidic platform, resulting in a thread-based electroanalytical device (μTED). The arrangement of μTED consists of two coupled electrodes (one reference in the inlet reservoir and an auxiliary electrode against the outlet reservoir) and a mobile support for facile working electrode exchange. After optimization of construction parameters, the system was applied for non-enzymatic determination of cholesterol under alkaline conditions using the redox pair Ni(II)/Ni(III) as a mediator. Under the best analytical conditions, a calibration curve was constructed with a linear dynamic range (LDR) from 0.25 to 25.0 μmol L-1, and the calculated limits of detection (LOD) and quantification (LOQ) were 0.074 and 0.24 μmol L-1, respectively. No effects of possible interferents on electrochemical response were found in the presence of ascorbic acid, uric acid, dopamine, cysteine, and glucose, suggesting that the proposed device can be used for the determination of cholesterol without significant matrix effects of human plasma. Finally, cholesterol analysis was carried out using spiked plasma samples, and good recovery values were achieved.
Collapse
Affiliation(s)
- Emily Yamagutti Watanabe
- Laboratório de Sensores Eletroquímicos (LabSensE) - Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba, CEP 81531-980, PR, Brazil.
| | - Ava Gevaerd
- Laboratório de Sensores Eletroquímicos (LabSensE) - Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba, CEP 81531-980, PR, Brazil.
- Hilab, Rua José Altair Possebom, 800, Curitiba, CEP 81270-185, PR, Brazil
| | - Fabio Roberto Caetano
- Laboratório de Sensores Eletroquímicos (LabSensE) - Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba, CEP 81531-980, PR, Brazil.
| | - Luiz Humberto Marcolino-Junior
- Laboratório de Sensores Eletroquímicos (LabSensE) - Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba, CEP 81531-980, PR, Brazil.
| | - Márcio Fernando Bergamini
- Laboratório de Sensores Eletroquímicos (LabSensE) - Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba, CEP 81531-980, PR, Brazil.
| |
Collapse
|
6
|
Zhao Z, Xiao J, Zhang X, Jiang J, Zhang M, Li Y, Li T, Wang J. A Thread-based Micro Device for Continuous Electrochemical Detection of Saliva Urea. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
|
7
|
Chen L, Ghiasvand A, Paull B. Applications of thread-based microfluidics: Approaches and options for detection. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
|
8
|
Handrea-Dragan IM, Botiz I, Tatar AS, Boca S. Patterning at the micro/nano-scale: Polymeric scaffolds for medical diagnostic and cell-surface interaction applications. Colloids Surf B Biointerfaces 2022; 218:112730. [DOI: 10.1016/j.colsurfb.2022.112730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/15/2022] [Accepted: 07/25/2022] [Indexed: 11/27/2022]
|
9
|
Oliveira ACM, Araújo DAG, Pradela-Filho LA, Takeuchi RM, Trindade MAG, Dos Santos AL. Threads in tubing: an innovative approach towards improved electrochemical thread-based microfluidic devices. LAB ON A CHIP 2022; 22:3045-3054. [PMID: 35833547 DOI: 10.1039/d2lc00387b] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Thread-based microfluidic analytical devices have received growing attention since threads have some advantages over other materials. Compared to paper, threads are also capable of spontaneously transporting fluid due to capillary action, but they have superior mechanical strength and do not require hydrophobic barriers. Therefore, thread-based microfluidic devices can be inexpensively fabricated with no need for external pumps or sophisticated microfabrication apparatus. Despite these outstanding features, achieving a controlled and continuous flow rate is still a challenging task, mainly due to fluid evaporation. Here, we overcome this challenge by inserting a cotton thread into a polyethylene tube aiming to minimize fluid evaporation. Also, a cotton piece was inserted into the outlet reservoir to improve the wicking ability of the device. This strategy enabled the fabrication of an innovative electrochemical thread in a tubing microfluidic device that was capable to hold a consistent flow rate (0.38 μL s-1) for prolonged periods, allowing up to 100 injections in a single device by simply replacing the cotton piece in the outlet reservoir. The proposed device displayed satisfactory analytical performance for selected model analytes (dopamine, hydrogen peroxide, and tert-butylhydroquinone), in addition to being successfully used for quantification of nitrite in spiked artificial saliva samples. Beyond the flow rate improvement, this "thread-in-tube" strategy ensured the protection of the fluid from external contamination while making it easier to connect the electrode array to the microchannels. Thus, we envision that the thread in a tube strategy could bring interesting improvements to thread-based microfluidic analytical devices.
Collapse
Affiliation(s)
- Ana Clara Maia Oliveira
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| | - Diele Aparecida Gouveia Araújo
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| | - Lauro Antonio Pradela-Filho
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| | - Regina Massako Takeuchi
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| | - Magno Aparecido Gonçalves Trindade
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, 79804-970 Dourados, Mato Grosso do Sul, Brazil
| | - André Luiz Dos Santos
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| |
Collapse
|
10
|
3D-printed microfluidic thread device with integrated detector: a green and portable tool for amperometric detection of fungicide benzovindiflupyr in forensic samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
11
|
Selvam G, Dheivasigamani T, Prabhu A, Mani NK. Embellishing 2-D MoS 2 Nanosheets on Lotus Thread Devices for Enhanced Hydrophobicity and Antimicrobial Activity. ACS OMEGA 2022; 7:24606-24613. [PMID: 35874217 PMCID: PMC9301725 DOI: 10.1021/acsomega.2c02337] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Herein, we report cellulose-based threads from Indian sacred Lotus (Nelumbo nucifera) of the Nymphaceae family embellished with MoS2 nanosheets for its enhanced hydrophobic and antimicrobial properties. MoS2 nanosheets synthesized by a coprecipitation method using sodium molybdate dihydrate (Na2MoO4·2H2O) and thioacetamide (CH3CSNH2) were used as a sourse for MoS2 particle growth with cellulose threads extracted from lotus peduncles. The size, crystallinity, and morphology of pure and MoS2-coated fibers were studied using X-ray diffractometry (XRD) and scanning electron microscopy (SEM). the XRD pattern of pure lotus threads showed a semicrystalline nature, and the threads@MoS2 composite showed more crystallinity than the pure threads. SEM depicts that pure lotus threads possess a smooth surface, and the MoS2 nanosheets growth can be easily identified on the threads@MoS2. Further, the presence of MoS2 nanosheets on threads was confirmed with EDX elemental analysis. Antimicrobial studies with Escherichia coli and Candida albicans reveal that threads@MoS2 have better resistance than its counterpart, i.e., pure threads. MoS2 sheets play a predominant role in restricting the wicking capability of the pure threads due to their enhanced hydrophobic property. The water absorbency assay denotes the absorption rate of threads@MoS2 to 80%, and threads@MoS2 shows no penetration for the observed 60 min, thus confirming its wicking restriction. The contact angle for threads@MoS2 is 128°, indicating its improved hydrophobicity.
Collapse
Affiliation(s)
- Govarthini
Seerangan Selvam
- Nano-crystal
Design and Application Lab (n-DAL), Department of Physics, PSG Institute of Technology and Applied Research, Coimbatore-641062, Tamil Nadu India
| | - Thangaraju Dheivasigamani
- Nano-crystal
Design and Application Lab (n-DAL), Department of Physics, PSG Institute of Technology and Applied Research, Coimbatore-641062, Tamil Nadu India
| | - Anusha Prabhu
- Microfluidics,
Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology,
Manipal Institute of Technology, Manipal
Academy of Higher Education, Manipal 576104, Karnataka India
| | - Naresh Kumar Mani
- Microfluidics,
Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology,
Manipal Institute of Technology, Manipal
Academy of Higher Education, Manipal 576104, Karnataka India
| |
Collapse
|
12
|
Alachkar A, Alhassan S, Senel M. Lab-In-A-Syringe: A Novel Electrochemical Biosensor for On-Site and Real-Time Monitoring of Dopamine in Freely Behaving Mice. ACS Sens 2022; 7:331-337. [PMID: 35006681 DOI: 10.1021/acssensors.1c02525] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
There is a growing demand for real-time analysis and sampling of biofluids on a single low-cost platform in ultralow fluid volumes with robustness. In this study, a microfluidic sensor was developed, manufactured through an additive manufacturing technique, and used for dopamine (DA) measurements. We implemented a biosensing system using pencil graphites (PGEs) integrated into a three-dimensional (3D) printed microfluidic syringe-type device (μSyringe). The amperometry technique was used to monitor the current changes associated with the electrooxidation of DA. The sensing signal was stable and linear in a concentration range of DA between the limit of quantification (0.1 nM) and the upper limit of linearity (500 nM). The μSyringe sensing device is simple, robust, and stable, making it suitable for real-time measurement of DA in cerebrospinal fluid (CSF) from freely moving mice.
Collapse
Affiliation(s)
- Amal Alachkar
- Department of Pharmaceutical Sciences, University of California, Irvine, California 92697-4625, United States
- Institute for Genomics and Bioinformatics, School of Information and Computer Sciences, University of California-Irvine, Irvine, California 92697-4625, United States
- Center for the Neurobiology of Learning and Memory, University of California-Irvine, Irvine, California 92697-4625, United States
| | - Sammy Alhassan
- Department of Pharmaceutical Sciences, University of California, Irvine, California 92697-4625, United States
| | - Mehmet Senel
- Department of Pharmaceutical Sciences, University of California, Irvine, California 92697-4625, United States
- Department of Biochemistry, Faculty of Pharmacy, Biruni University, Istanbul 34010, Turkey
| |
Collapse
|
13
|
Agustini D, Caetano FR, Quero RF, Fracassi da Silva JA, Bergamini MF, Marcolino-Junior LH, de Jesus DP. Microfluidic devices based on textile threads for analytical applications: state of the art and prospects. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4830-4857. [PMID: 34647544 DOI: 10.1039/d1ay01337h] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic devices based on textile threads have interesting advantages when compared to systems made with traditional materials, such as polymers and inorganic substrates (especially silicon and glass). One of these significant advantages is the device fabrication process, made more cheap and simple, with little or no microfabrication apparatus. This review describes the fundamentals, applications, challenges, and prospects of microfluidic devices fabricated with textile threads. A wide range of applications is discussed, integrated with several analysis methods, such as electrochemical, colorimetric, electrophoretic, chromatographic, and fluorescence. Additionally, the integration of these devices with different substrates (e.g., 3D printed components or fabrics), other devices (e.g., smartphones), and microelectronics is described. These combinations have allowed the construction of fully portable devices and consequently the development of point-of-care and wearable analytical systems.
Collapse
Affiliation(s)
- Deonir Agustini
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | - Fábio Roberto Caetano
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | - Reverson Fernandes Quero
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
| | - José Alberto Fracassi da Silva
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
- Instituto Nacional de Ciência e Tecnologia em Bioanalítica (INCTBio), Campinas, SP, Brazil
| | - Márcio Fernando Bergamini
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | | | - Dosil Pereira de Jesus
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
- Instituto Nacional de Ciência e Tecnologia em Bioanalítica (INCTBio), Campinas, SP, Brazil
| |
Collapse
|
14
|
Prabhu A, Singhal H, Giri Nandagopal MS, Kulal R, Peralam Yegneswaran P, Mani NK. Knitting Thread Devices: Detecting Candida albicans Using Napkins and Tampons. ACS OMEGA 2021; 6:12667-12675. [PMID: 34056418 PMCID: PMC8154238 DOI: 10.1021/acsomega.1c00806] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Accepted: 04/22/2021] [Indexed: 05/14/2023]
Abstract
Reproducible and in situ microbial detection, particularly of microbes significant in urinary tract infections (UTIs) such as Candida albicans, provides a unique opportunity to bring equity in the healthcare outcomes of disenfranchised groups like women in low-resource settings. Here, we demonstrate a system to potentially detect vulvovaginal candidiasis by leveraging the properties of multifilament cotton threads in the form of microfluidic-thread-based analytical devices (μTADs) to develop a frugal microbial identification assay. A facile mercerization method using heptane wash to boost reagent absorption and penetration is also performed and is shown to be robust compared to other existing conventional mercerization methods. Furthermore, the twisted mercerized fibers are drop-cast with media consisting of l-proline β-naphthylamide, which undergoes hydrolysis by the enzyme l-proline aminopeptidase secreted by C. albicans, hence signaling the presence of the pathogen via simple color change with a limit of detection of 0.58 × 106 cfu/mL. The flexible and easily disposable thread-based detection device when integrated with menstrual hygiene products showed a detection time of 10 min using spiked vaginal discharge. The developed method boasts a long shelf life and high stability, making it a discreet detection device for testing, which provides new vistas for self-testing multiple diseases that are considered taboo in certain societies.
Collapse
Affiliation(s)
- Anusha Prabhu
- Department
of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - Hardik Singhal
- Department
of Chemical Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - M. S. Giri Nandagopal
- Department
of Mechanical Engineering, Indian Institute
of Technology, Kharagpur, Kharagpur 721302, India
| | - Reshma Kulal
- Department
of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - Prakash Peralam Yegneswaran
- Department
of Microbiology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
- Manipal
Centre for Infectious Diseases, Prasanna School of Public Health, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - Naresh Kumar Mani
- Department
of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
- Manipal
Centre for Infectious Diseases, Prasanna School of Public Health, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| |
Collapse
|
15
|
Carvalho RM, Ferreira VS, Lucca BG. A novel all-3D-printed thread-based microfluidic device with an embedded electrochemical detector: first application in environmental analysis of nitrite. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1349-1357. [PMID: 33656036 DOI: 10.1039/d1ay00070e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A microfluidic thread electroanalytical device (μTED) containing an embedded electrochemical detector is presented for the first time in this work. This novel device was entirely produced in an automated way using the fused deposition modeling (FDM) 3D printing technique. The main platform was fabricated with acrylonitrile butadiene styrene (ABS) filament, while the integrated electrochemical detector was produced using a commercial conductive filament composed of carbon black and polylactic acid (CB/PLA). The microfluidic channels consisted of cotton threads, which act as passive pumps, and the μTED was used for microflow injection analysis (μFIA). As a proof of concept, this μFIA system was utilized for the amperometric sensing of nitrite in natural waters. This is the first report on the use of both μTEDs and 3D-printed CB/PLA electrodes to determine this species. This fully 3D-printed μTED was characterized and all experimental and instrumental parameters related to the method were studied and optimized. Using the best conditions, the proposed approach showed a linear response in the concentration range from 8 to 200 μmol L-1 and a limit of detection (LOD) of 2.39 μmol L-1. The LOD obtained here was ca. ten-fold lower than the maximum contaminant level for nitrite in drinking water established by the Brazilian and US legislation. Moreover, the platform presented good repeatability and reproducibility (relative standard deviations (RSDs) were 2.1% and 2.5%, respectively). Lastly, the 3D-printed μTED was applied for the quantification of nitrite in well water samples and the results obtained showed good precision (RSD < 3%) and excellent concordance (relative error was ca.±3%) with those achieved by ion chromatography, used for validation.
Collapse
Affiliation(s)
- Rayan Marcel Carvalho
- Chemistry Institute, Federal University of Mato Grosso do Sul, Campo Grande, MS 79074-460, Brazil.
| | | | | |
Collapse
|
16
|
Senel M, Alachkar A. Lab-in-a-pencil graphite: A 3D-printed microfluidic sensing platform for real-time measurement of antipsychotic clozapine level. LAB ON A CHIP 2021; 21:405-411. [PMID: 33331378 DOI: 10.1039/d0lc00970a] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A novel lab-in-a-pencil graphite microfluidic sensing electrode (μFSE) was fabricated for real-time flow injection measurement of the antipsychotic drug clozapine (Clz). A simple, low-cost, and reusable μFSE was obtained by using 3D printing of a microfluidic chamber integrated with a flat pencil graphite without the need to utilize complex technologies. The μFSE has tubular geometry with 800 μm diameter, where the solution continuously flows in the holes of flat pencil graphite electrodes. Under optimized conditions, this device offers fast and effective Clz detection with good analytical features. A linear calibration curve in the range of 0.5 to 10 μM Clz was obtained with good sensitivity (0.01275 μA μM-1) and detection limit (24 nM). Finally, we demonstrate the applicability of our lab-fabricated microfluidic electrochemical device by monitoring Clz in serum samples at low concentrations.
Collapse
Affiliation(s)
- Mehmet Senel
- Department of Pharmaceutical Sciences, School of Pharmacy and Pharmaceutical Sciences, University of California, Irvine, CA 92697-4625, USA.
| | | |
Collapse
|
17
|
Kaewjua K, Nakthong P, Chailapakul O, Siangproh W. Flow-based System: A Highly Efficient Tool Speeds Up Data Production and Improves Analytical Performance. ANAL SCI 2021; 37:79-92. [PMID: 32981899 DOI: 10.2116/analsci.20sar02] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In this review, we cite references from the period between 2015 and 2020 related to the use of a flow-based system as a tool to obtain a modern analytical system for speeding up data production and improving performance. Based on a great deal of concepts for automatic systems, there are several research groups introduced in the development of flow-based systems to increase sample throughput while retaining the reproducibility and repeatability as well as to propose new platforms of flow-based systems, such as microfluidic chip and paper-based devices. Additionally, to apply a developed system for on-site analysis is one of the key features for development. We believe that this review will be very interested and useful for readers because of its impact on developing novel analytical systems. The content of the review is categorized following their applications including quality control and food safety, clinical diagnostics, environmental monitoring and miscellaneous.
Collapse
Affiliation(s)
- Kantima Kaewjua
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Prangthip Nakthong
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence, Department of Chemistry, Faculty of Science, Bangkok, 10330, Thailand
| | - Weena Siangproh
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand.
| |
Collapse
|
18
|
Ferreira TA, Guevara-Lara A, Paez-Hernandez ME, Mondragon AC, Rodriguez JA. Micro flow injection analysis of leucomalachite green in fish muscle using modified henequen fibers as microfluidic channels. RSC Adv 2021; 11:35375-35382. [PMID: 35493172 PMCID: PMC9042840 DOI: 10.1039/d1ra06301d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 10/25/2021] [Indexed: 12/03/2022] Open
Abstract
In this work a simple and novel procedure for leucomalachite green determination based on micro flow injection analysis (μFIA) with amperometric detection is presented. The method involves the use of henequen modified fibers as microfluidic channels. The μFIA system proposed offers a simple, rapid, and low-cost alternative for the determination. Capillary and gravitational forces across the modified henequen fibers control the flow rate, eliminating the need for external pumps. This technique requires low reagent consumption and allows portability for in situ measurements. The flow system is described, and the operational variables were studied and optimized using a Taguchi parameters design to increase analytical sensitivity. Under optimal conditions a limit of detection of 1.16 μg kg−1 was achieved with adequate repeatability and reproducibility (expressed as %RSD <5.0%, n = 3, n = 9 respectively) in all cases. The effect of interfering species and the accuracy of the method were also investigated. The proposed methodology was validated and applied to determine LMG in tilapia muscle samples. In this work a simple and novel procedure for leucomalachite green determination based on micro flow injection analysis (μFIA) with amperometric detection is presented.![]()
Collapse
Affiliation(s)
- T. Alexandra Ferreira
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Mineral de la Reforma, Hidalgo, Mexico
| | - Alfredo Guevara-Lara
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Mineral de la Reforma, Hidalgo, Mexico
| | - M. Elena Paez-Hernandez
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Mineral de la Reforma, Hidalgo, Mexico
| | - Alicia C. Mondragon
- Laboratorio de Higiene, Inspeccion y Control de Alimentos, Departamento de Química Analitica, Nutricion y Bromatologia, Facultad de Veterinaria, Universidad de Santiago de Compostela, 27002, Lugo, Spain
| | - Jose A. Rodriguez
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Mineral de la Reforma, Hidalgo, Mexico
| |
Collapse
|
19
|
Di Masi S, Laschi S, Pennetta A, Faraoni P, Ranaldi F, De Benedetto GE, Malitesta C. Microfluidic Setup for Simultaneous Separation and Electrochemical Determination of Hg
2+
and Ag
+
Ions in Water. ELECTROANAL 2020. [DOI: 10.1002/elan.202060479] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Sabrina Di Masi
- Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali University of Salento Via Monteroni 73100 Lecce Italy
| | - Serena Laschi
- Ecobioservices and Researches SrL Via Madonna del Piano 6 50019 Sesto Fiorentino Firenze Italy
| | - Antonio Pennetta
- Dipartimento di Beni Culturali Via per Monteroni 73100 Lecce Italy
| | - Paola Faraoni
- Ecobioservices and Researches SrL Via Madonna del Piano 6 50019 Sesto Fiorentino Firenze Italy
- Laboratorio Congiunto NanoBioSens, Dipartimento di Scienze Biomediche Sperimentali e Cliniche “Mario Serio” Università degli Studi di Firenze Viale Pieraccini 6 50139 Firenze Italy
| | - Francesco Ranaldi
- Laboratorio Congiunto NanoBioSens, Dipartimento di Scienze Biomediche Sperimentali e Cliniche “Mario Serio” Università degli Studi di Firenze Viale Pieraccini 6 50139 Firenze Italy
| | | | - Cosimino Malitesta
- Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali University of Salento Via Monteroni 73100 Lecce Italy
| |
Collapse
|
20
|
Liu Z, Ye D, Wang S, Zhu X, Chen R, Liao Q. Single-Stream H 2O 2 Membraneless Microfluidic Fuel Cell and Its Application as a Self-Powered Electrochemical Sensor. Ind Eng Chem Res 2020. [DOI: 10.1021/acs.iecr.0c02548] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Zhenfei Liu
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Dingding Ye
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Shaolong Wang
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Xun Zhu
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Rong Chen
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Qiang Liao
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| |
Collapse
|
21
|
Prabhu A, Nandagopal M S G, Peralam Yegneswaran P, Prabhu V, Verma U, Mani NK. Thread integrated smart-phone imaging facilitates early turning point colorimetric assay for microbes. RSC Adv 2020; 10:26853-26861. [PMID: 35515782 PMCID: PMC9055509 DOI: 10.1039/d0ra05190j] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 07/13/2020] [Indexed: 12/19/2022] Open
Abstract
This study employs a commercial multifilament cotton thread as a low-cost microbial identification assay integrated with smartphone-based imaging for high throughput and rapid detection of pathogens. The thread device with inter-twined fibers was drop-cast with test media and a pH indicator. The target pathogens scavenge the media components with different sugars and release acidic by-products, which in turn act as markers for pH-based color change. The developed thread-based proof-of-concept was demonstrated for the visual color detection (red to yellow) of Candida albicans (≈16 hours) and Escherichia coli (≈5 hours). Besides that, using a smart-phone to capture images of the thread-based colorimetric assay facilitates early detection of turning point of the pH-based color change and further reduces the detection time of pathogens viz. Candida albicans (≈10 hours) and Escherichia coli (≈1.5 hours). The reported thread and smartphone integrated image analysis works towards identifying the turning point of the colorimetric change rather than the end-point analysis. Using this approach, the interpretation time can be significantly reduced compared to the existing conventional microbial methods (≈24 hours). The thread-based colorimetric microbial assay represents a ready-to-use, low-cost and straightforward technology with applicability in resource-constrained environments, surpassing the need for frequent fresh media preparation, expensive instrumentation, complex fabrication techniques and expert intervention. The proposed method possesses high scalability and reproducibility, which can be further extended to bio(chemical) assays.
Collapse
Affiliation(s)
- Anusha Prabhu
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal 576104 Karnataka India
| | - Giri Nandagopal M S
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur 721302 India
| | - Prakash Peralam Yegneswaran
- Department of Microbiology, Kasturba Medical College Manipal, Manipal Academy of Higher Education Manipal 576104 Karnataka India
- Manipal Center for Infectious Diseases, Prasanna School of Public Health, Manipal Academy of Higher Education Manipal 576104 Karnataka India
| | - Vijendra Prabhu
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal 576104 Karnataka India
| | - Ujjwal Verma
- Department of Electronics & Communication, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal 576104 Karnataka India
- Manipal Center for Infectious Diseases, Prasanna School of Public Health, Manipal Academy of Higher Education Manipal 576104 Karnataka India
| | - Naresh Kumar Mani
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal 576104 Karnataka India
- Manipal Center for Infectious Diseases, Prasanna School of Public Health, Manipal Academy of Higher Education Manipal 576104 Karnataka India
| |
Collapse
|
22
|
|
23
|
Narayanamurthy V, Jeroish ZE, Bhuvaneshwari KS, Bayat P, Premkumar R, Samsuri F, Yusoff MM. Advances in passively driven microfluidics and lab-on-chip devices: a comprehensive literature review and patent analysis. RSC Adv 2020; 10:11652-11680. [PMID: 35496619 PMCID: PMC9050787 DOI: 10.1039/d0ra00263a] [Citation(s) in RCA: 92] [Impact Index Per Article: 18.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 02/20/2020] [Indexed: 12/15/2022] Open
Abstract
The development of passively driven microfluidic labs on chips has been increasing over the years. In the passive approach, the microfluids are usually driven and operated without any external actuators, fields, or power sources. Passive microfluidic techniques adopt osmosis, capillary action, surface tension, pressure, gravity-driven flow, hydrostatic flow, and vacuums to achieve fluid flow. There is a great need to explore labs on chips that are rapid, compact, portable, and easy to use. The evolution of these techniques is essential to meet current needs. Researchers have highlighted the vast potential in the field that needs to be explored to develop rapid passive labs on chips to suit market/researcher demands. A comprehensive review, along with patent analysis, is presented here, listing the latest advances in passive microfluidic techniques, along with the related mechanisms and applications.
Collapse
Affiliation(s)
- Vigneswaran Narayanamurthy
- Department of Electronics and Computer Engineering Technology, Faculty of Electrical and Electronic Engineering Technology, Universiti Teknikal Malaysia Melaka Hang Tuah Jaya 76100 Durian Tunggal Melaka Malaysia
- InnoFuTech No: 42/12, 7th Street, Vallalar Nagar Chennai Tamil Nadu 600072 India
- Centre of Excellence for Advanced Research in Fluid Flow, University Malaysia Pahang Kuantan 26300 Malaysia
| | - Z E Jeroish
- Department of Biomedical Engineering, Rajalakshmi Engineering College Chennai 602105 India
- Faculty of Electrical and Electronics Engineering, University Malaysia Pahang Pekan 26600 Malaysia
| | - K S Bhuvaneshwari
- Department of Biomedical Engineering, Rajalakshmi Engineering College Chennai 602105 India
- Faculty of Electronics and Computer Engineering, Universiti Teknikal Malaysia Melaka Hang Tuah Jaya 76100 Durian Tunggal Melaka Malaysia
| | - Pouriya Bayat
- Department of Bioengineering, McGill University Montreal QC Canada H3A 0E9
| | - R Premkumar
- Department of Biomedical Engineering, Rajalakshmi Engineering College Chennai 602105 India
| | - Fahmi Samsuri
- Faculty of Electrical and Electronics Engineering, University Malaysia Pahang Pekan 26600 Malaysia
| | - Mashitah M Yusoff
- Faculty of Industrial Sciences and Technology, University Malaysia Pahang Kuantan 26300 Malaysia
| |
Collapse
|
24
|
Sato R, Yamada R, Masadome T. Development of an Optode Detector for Determination of Anionic Surfactants by Flow Injection Analysis. ANAL SCI 2020; 36:379-383. [PMID: 31708558 DOI: 10.2116/analsci.19n026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A flow-injection analysis (FIA) method for assaying an anionic surfactant (AS) using AS optode detector was demonstrated. The optode membrane consists of 2-nitrophenyl octyl ether as a plasticizer, lactone form rhodamine B (L-RB) and poly(vinyl chloride). The linear response concentration range of the AS optode to AS was 20 - 100 μmol dm-3 in the FIA system. The sampling rate for an AS ion (40 μmol dm-3 sodium dodecylbenzenesulfonate) in the proposed FIA system was ca. 5 samples h-1. The AS level in commercially available laundry detergents by the proposed FIA system was determined.
Collapse
Affiliation(s)
- Ryota Sato
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| | - Ryo Yamada
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| | - Takashi Masadome
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| |
Collapse
|
25
|
Elomaa J, Gallegos L, Gomez FA. Cord-Based Microfluidic Chips as A Platform for ELISA and Glucose Assays. MICROMACHINES 2019; 10:mi10090614. [PMID: 31540182 PMCID: PMC6780352 DOI: 10.3390/mi10090614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Revised: 09/03/2019] [Accepted: 09/13/2019] [Indexed: 05/13/2023]
Abstract
This paper describes the development and application of microfluidic cord-based analytical devices (µCADs) in two enzyme-linked immunosorbent assays (ELISAs) and glucose assay. In this study, biotinylated goat anti-mouse immunoglobulin (IgG) antibody, rabbit IgG antibody, and glucose are quantitatively detected. In the ELISA systems, the antibody is spotted on the cord at the detection site and a series of washes, followed by streptavidin-alkaline phosphatase (Strep-ALP) or alkaline phosphatase (ALP)-conjugated secondary antibody and colorimetric substrate, completing the experiment. The devices are subsequently scanned and analyzed yielding a correlation between inverse yellow or inverse blue intensity and antibody concentration. For the first ELISA, a linear range of detection was observed at lower concentrations (2.50 × 10-4-1.75 × 10-3 mg/mL) of Strep-ALP with saturation of the enzyme achieved at higher concentrations (>2.50 × 10-4). For the second ELISA, the L50 was demonstrated to be 167.6 fmol/zone. The glucose assay consisted of spotting increasing concentrations of glucose on the analysis sites and transporting, via capillary action, a solution containing glucose oxidase (GOx), horseradish peroxidase (HRP), and potassium iodide (KI) to the detection sites realizing a yellow-brown color indicating oxidation of iodide to iodine. The device was then dried, scanned, and analyzed to show the correlation between yellow inverse intensity and glucose. Glucose in artificial urine showed good correlation using the devices.
Collapse
Affiliation(s)
- Jenny Elomaa
- Department of Chemistry and Biochemistry, California State University, Los Angeles, 5151 State University Drive, Los Angeles, CA 90032-8202, USA.
| | - Laura Gallegos
- Department of Chemistry and Biochemistry, California State University, Los Angeles, 5151 State University Drive, Los Angeles, CA 90032-8202, USA.
| | - Frank A Gomez
- Department of Chemistry and Biochemistry, California State University, Los Angeles, 5151 State University Drive, Los Angeles, CA 90032-8202, USA.
| |
Collapse
|
26
|
Kalinke C, Wosgrau V, Oliveira PR, Oliveira GA, Martins G, Mangrich AS, Bergamini MF, Marcolino-Junior LH. Green method for glucose determination using microfluidic device with a non-enzymatic sensor based on nickel oxyhydroxide supported at activated biochar. Talanta 2019; 200:518-525. [DOI: 10.1016/j.talanta.2019.03.079] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 03/19/2019] [Accepted: 03/20/2019] [Indexed: 01/22/2023]
|
27
|
Weng X, Kang Y, Guo Q, Peng B, Jiang H. Recent advances in thread-based microfluidics for diagnostic applications. Biosens Bioelectron 2019; 132:171-185. [PMID: 30875629 PMCID: PMC7127036 DOI: 10.1016/j.bios.2019.03.009] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 03/02/2019] [Accepted: 03/07/2019] [Indexed: 02/06/2023]
Abstract
Over the past decades, researchers have been seeking attractive substrate materials to keep microfluidics improving to outbalance the drawbacks and issues. Cellulose substrates, including thread, paper and hydrogels are alternatives due to their distinct structural and mechanical properties for a number of applications. Thread have gained considerable attention and become promising powerful tool due to its advantages over paper-based systems thus finds numerous applications in the development of diagnostic systems, smart bandages and tissue engineering. To the best of our knowledge, no comprehensive review articles on the topic of thread-based microfluidics have been published and it is of significance for many scientific communities working on Microfluidics, Biosensors and Lab-on-Chip. This review gives an overview of the advances of thread-based microfluidic diagnostic devices in a variety of applications. It begins with an overall introduction of the fabrication followed by an in-depth review on the detection techniques in such devices and various applications with respect to effort and performance to date. A few perspective directions of thread-based microfluidics in its development are also discussed. Thread-based microfluidics are still at an early development stage and further improvements in terms of fabrication, analytical strategies, and function to become low-cost, low-volume and easy-to-use point-of-care (POC) diagnostic devices that can be adapted or commercialized for real world applications.
Collapse
Affiliation(s)
- Xuan Weng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Yuejun Kang
- Institute for Clean Energy and Advanced Materials, Faculty of Materials and Energy, Southwest University, Chongqing 400715, China
| | - Qian Guo
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Bei Peng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China.
| |
Collapse
|
28
|
Nonenzymatic sensor for determination of glucose in blood plasma based on nickel oxyhydroxide in a microfluidic system of cotton thread. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.03.038] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
29
|
Farajikhah S, Cabot JM, Innis PC, Paull B, Wallace G. Life-Saving Threads: Advances in Textile-Based Analytical Devices. ACS COMBINATORIAL SCIENCE 2019; 21:229-240. [PMID: 30640423 DOI: 10.1021/acscombsci.8b00126] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Novel approaches that incorporate electrofluidic and microfluidic technologies are reviewed to illustrate the translation of traditional enclosed structures into open and accessible textile based platforms. Through the utilization of on-fiber and on-textile microfluidics, it is possible to invert the typical enclosed capillary column or microfluidic "chip" platform, to achieve surface accessible efficient separations and fluid handling, while maintaining a microfluidic environment. The open fiber/textile based fluidics approach immediately provides new possibilities to interrogate, manipulate, redirect, extract, characterize, and quantify solutes and target species at any point in time during such processes as on-fiber electrodriven separations. This approach is revolutionary in its simplicity and provides many potential advantages not otherwise afforded by the more traditional enclosed platforms.
Collapse
Affiliation(s)
- Syamak Farajikhah
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
| | - Joan M. Cabot
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, Faculty of Chemistry, University of Tasmania, Tasmania 7005, Australia
| | - Peter C. Innis
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility − Materials Node, Innovation Campus, University of Wollongong, New South Wales 2522, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, Faculty of Chemistry, University of Tasmania, Tasmania 7005, Australia
| | - Gordon Wallace
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility − Materials Node, Innovation Campus, University of Wollongong, New South Wales 2522, Australia
| |
Collapse
|
30
|
Dossi N, Toniolo R, Terzi F, Sdrigotti N, Tubaro F, Bontempelli G. A cotton thread fluidic device with a wall-jet pencil-drawn paper based dual electrode detector. Anal Chim Acta 2018; 1040:74-80. [DOI: 10.1016/j.aca.2018.06.061] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 06/21/2018] [Accepted: 06/22/2018] [Indexed: 10/28/2022]
|
31
|
Kurbanoglu S, Unal MA, Ozkan SA. Recent developments on electrochemical flow injection in pharmaceuticals and biologically important compounds. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.04.217] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
32
|
Ashagre MA, Masadome T. A New Microfluidic Polymer Chip with an Embedded Cationic Surfactant Ion-selective Optode as a Detector for the Determination of Cationic Surfactants. ANAL SCI 2018; 34:195-199. [PMID: 29434106 DOI: 10.2116/analsci.34.195] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A new microfluidic polymer chip with an embedded cationic surfactant (CS) ion-selective optode (CS-optode) as a detector of flow-injection analysis (FIA) for the determination of CSs was developed. The optode sensing membrane is based on a poly(vinyl chloride) membrane plasticized with 2-nitrophenyl octyl ether containing tetrabromophenolphthalein ethyl ester. Under the optimal flow conditions of the FIA system, the CS-optode showed a good linear relationship between the peak heights in the absorbance, and the concentrations of CS in a concentration range from 50 to 400 μmol dm-3. The sample throughput of the present system for the determination of a CS ion (300 μmol dm-3 zephiramine) was ca. 11 samples h-1. The proposed FIA system was applied to determine the level of CS in dental rinses.
Collapse
Affiliation(s)
| | - Takashi Masadome
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| |
Collapse
|
33
|
Caetano F, Carneiro E, Agustini D, Figueiredo-Filho L, Banks C, Bergamini M, Marcolino-Junior L. Combination of electrochemical biosensor and textile threads: A microfluidic device for phenol determination in tap water. Biosens Bioelectron 2018; 99:382-388. [DOI: 10.1016/j.bios.2017.07.070] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 07/18/2017] [Accepted: 07/28/2017] [Indexed: 11/26/2022]
|
34
|
Agustini D, Bergamini MF, Marcolino-Junior LH. Tear glucose detection combining microfluidic thread based device, amperometric biosensor and microflow injection analysis. Biosens Bioelectron 2017; 98:161-167. [DOI: 10.1016/j.bios.2017.06.035] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Revised: 06/07/2017] [Accepted: 06/16/2017] [Indexed: 11/16/2022]
|
35
|
Carneiro EA, Agustini D, Figueiredo-Filho LCS, Banks CE, Marcolino-Junior LH, Bergamini MF. 3D-printed Microfluidic Device Based on Cotton Threads for Amperometric Estimation of Antioxidants in Wine Samples. ELECTROANAL 2017. [DOI: 10.1002/elan.201700579] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Emmanuelle A. Carneiro
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química; Universidade Federal do Paraná (UFPR); CEP 81.531-980 Curitiba-PR Brazil
| | - Deonir Agustini
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química; Universidade Federal do Paraná (UFPR); CEP 81.531-980 Curitiba-PR Brazil
| | | | - Craig E. Banks
- Faculty of Science and Engineering; Manchester Metropolitan University; Chester Street Manchester M1 5GD UK
| | - Luiz Humberto Marcolino-Junior
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química; Universidade Federal do Paraná (UFPR); CEP 81.531-980 Curitiba-PR Brazil
| | - Márcio F. Bergamini
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química; Universidade Federal do Paraná (UFPR); CEP 81.531-980 Curitiba-PR Brazil
| |
Collapse
|