1
|
Chen L, Yang G, Qu F. Aptamer-based sensors for fluid biopsies of protein disease markers. Talanta 2024; 276:126246. [PMID: 38796994 DOI: 10.1016/j.talanta.2024.126246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2024] [Revised: 05/08/2024] [Accepted: 05/10/2024] [Indexed: 05/29/2024]
Abstract
Fluid biopsy technology, characterized by its minimally invasive nature, speed, and continuity, has become a rapidly advancing and widely applied real-time diagnostic technique. Among various biomarkers, proteins represent the most abundant class of disease indicators. The sensitive and accurate detection of protein markers in bodily fluids is significantly influenced by the control exerted by recognition ligands. Aptamers, which are structurally dynamic functional oligonucleotides, exhibit high affinity, specific recognition of targets, and notable characteristics of high editability and modularity. These features make aptamer universal "recognition-capture" components, contribute to a significant leap in their applications within the biosensor domain. In this context, we provide a comprehensive review of the extensive application of aptamer-based biosensors in fluid biopsy. We systematically compile the characteristics and construction strategies of aptamer-based biosensors tailored for fluid biopsy, including aptamer sequences, affinity (KD), fluid background, sensing technologies, sensor construction strategies, incubation time, detection performance, and influencing factors. Furthermore, a comparative analysis of their advantages and disadvantages was conducted. In conclusion, we delineate and deliberate on prospective research trajectories and challenges that lie ahead in the realm of aptamer-based biosensors for fluid biopsy.
Collapse
Affiliation(s)
- Li Chen
- School of Life Science, Key Laboratory of Molecular Medicine and Biotherapy, Key Laboratory of Medical Molecule Science and Pharmaceutics Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Ge Yang
- CAMS Key Laboratory of Antiviral Drug Research, Beijing Key Laboratory of Antimicrobial Agents, NHC Key Laboratory of Biotechnology of Antibiotics, Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China.
| | - Feng Qu
- School of Life Science, Key Laboratory of Molecular Medicine and Biotherapy, Key Laboratory of Medical Molecule Science and Pharmaceutics Engineering, Beijing Institute of Technology, Beijing, 100081, China.
| |
Collapse
|
2
|
Liu Z, Duan X, Yun Y, Li S, Feng Z, Zhan J, Liu R, Li Y, Zhang J. Photoactivatable Aptamer-CRISPR Nanodevice Enables Precise Profiling of Interferon-Gamma Release in Humanized Mice. ACS NANO 2024; 18:3826-3838. [PMID: 38241471 DOI: 10.1021/acsnano.3c12499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/21/2024]
Abstract
Real-time dynamic imaging of immunoactivation-related cytokines is crucial for evaluating the efficacy of immune checkpoint blockade therapy and optimizing the treatment regimen. We introduce herein a spatiotemporally controlled nanodevice that allows in situ photoactivated imaging of interferon-gamma (IFN-γ) secretion from T cells in vitro and in vivo. The nanodevice is constructed by rational engineering of an aptamer-embedded, UV-cleavable PC-DNA probe and further integration with upconversion nanoparticles- and CRISPR-Cas12a-enhanced fluorescence systems. Using human peripheral blood mononuclear cells (PBMC)-engrafted mouse models, this nanodevice allows for the quantitative imaging of endogenous IFN-γ and its intratumoral dynamics responding to antiprogrammed cell death receptor 1 (anti-PD-1) therapy. This study thus provides a toolbox for boosting the sensitivity and precision of cytokine imaging during immune checkpoint blockade therapy, enlightening research toward imaging-guided tumor therapy.
Collapse
Affiliation(s)
- Zheng Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing 210023, China
| | - Xiang Duan
- State Key Laboratory of Pharmaceutical Biotechnology, National Resource Center for Mutant Mice, MOE Key Laboratory of Model Animals for Disease Study, MOE Engineering Research Center of Protein and Peptide Medicine, Chemistry and Biomedicine Innovation Center, Jiangsu Key Laboratory of Molecular Medicine, Model Animal Research Center, Medical School of Nanjing University, Nanjing 210061, China
| | - Yangfang Yun
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing 210023, China
| | - Siqi Li
- State Key Laboratory of Pharmaceutical Biotechnology, National Resource Center for Mutant Mice, MOE Key Laboratory of Model Animals for Disease Study, MOE Engineering Research Center of Protein and Peptide Medicine, Chemistry and Biomedicine Innovation Center, Jiangsu Key Laboratory of Molecular Medicine, Model Animal Research Center, Medical School of Nanjing University, Nanjing 210061, China
| | - Zhiyuan Feng
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing 210023, China
| | - Jiayin Zhan
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing 210023, China
| | - Ran Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing 210023, China
| | - Yan Li
- State Key Laboratory of Pharmaceutical Biotechnology, National Resource Center for Mutant Mice, MOE Key Laboratory of Model Animals for Disease Study, MOE Engineering Research Center of Protein and Peptide Medicine, Chemistry and Biomedicine Innovation Center, Jiangsu Key Laboratory of Molecular Medicine, Model Animal Research Center, Medical School of Nanjing University, Nanjing 210061, China
| | - Jingjing Zhang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing 210023, China
| |
Collapse
|
3
|
Kong F, Luo J, Jing L, Wang Y, Shen H, Yu R, Sun S, Xing Y, Ming T, Liu M, Jin H, Cai X. Reduced Graphene Oxide and Gold Nanoparticles-Modified Electrochemical Aptasensor for Highly Sensitive Detection of Doxorubicin. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1223. [PMID: 37049316 PMCID: PMC10096947 DOI: 10.3390/nano13071223] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 03/23/2023] [Accepted: 03/27/2023] [Indexed: 06/19/2023]
Abstract
Doxorubicin (DOX) is the most clinically important antibiotic in cancer treatment, but its severe cardiotoxicity and other side effects limit its clinical use. Therefore, monitoring DOX concentrations during therapy is essential to improve efficacy and reduce adverse effects. Here, we fabricated a sensitive electrochemical aptasensor for DOX detection. The sensor used gold wire as the working electrode and was modified with reduced graphene oxide (rGO)/gold nanoparticles (AuNPs) to improve the sensitivity. An aptamer was used as the recognition element for the DOX. The 5' end of the aptamer was modified with a thiol group, and thus immobilized to the AuNPs, and the 3' end was modified with methylene blue, which acts as the electron mediator. The combination between the aptamer and DOX would produce a binding-induced conformation, which changes the electron transfer rate, yielding a current change that correlates with the concentration of DOX. The aptasensor exhibited good linearity in the DOX concentration range of 0.3 μM to 6 μM, with a detection limit of 0.1 μM. In addition, the aptasensor was used for DOX detection in real samples and results, and showed good recovery. The proposed electrochemical aptasensor will provide a sensitive, fast, simple, and reliable new platform for detecting DOX.
Collapse
Affiliation(s)
- Fanli Kong
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jinping Luo
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Luyi Jing
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yiding Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Huayu Shen
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
| | - Rong Yu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
| | - Shuai Sun
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yu Xing
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Tao Ming
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Meiting Liu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hongyan Jin
- Obstetrics and Gynecology Department, Peking University First Hospital, Beijing 100034, China
| | - Xinxia Cai
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
4
|
Ming T, Luo J, Xing Y, Cheng Y, Liu J, Sun S, Kong F, Xu S, Dai Y, Xie J, Jin H, Cai X. Recent progress and perspectives of continuous in vivo testing device. Mater Today Bio 2022; 16:100341. [PMID: 35875195 PMCID: PMC9305619 DOI: 10.1016/j.mtbio.2022.100341] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 06/22/2022] [Accepted: 06/23/2022] [Indexed: 11/26/2022] Open
Abstract
Devices for continuous in-vivo testing (CIVT) can detect target substances in real time, thus providing a valuable window into a patient's condition, their response to therapeutics, metabolic activities, and neurotransmitter transmission in the brain. Therefore, CIVT devices have received increased attention because they are expected to greatly assist disease diagnosis and treatment and research on human pathogenesis. However, CIVT has been achieved for only a few markers, and it remains challenging to detect many key markers. Therefore, it is important to summarize the key technologies and methodologies of CIVT, and to examine the direction of future development of CIVT. We review recent progress in the development of CIVT devices, with consideration of the structure of these devices, principles governing continuous detection, and nanomaterials used for electrode modification. This detailed and comprehensive review of CIVT devices serves three purposes: (1) to summarize the advantages and disadvantages of existing devices, (2) to provide a reference for development of CIVT equipment to detect additional important markers, and (3) to discuss future prospects with emphasis on problems that must be overcome for further development of CIVT equipment. This review aims to promote progress in research on CIVT devices and contribute to future innovation in personalized medical treatments. A detailed and comprehensive review of continuous in vivo testing device. The nanomaterials, delicate structures and detection principles of the works are discussed. The achievements and shortcomings of the existing devices are summarized. The problems that should be solved in the further development of the devices and the future prospects are put forward.
Collapse
Affiliation(s)
- Tao Ming
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Jinping Luo
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yu Xing
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yan Cheng
- Obstetrics and Gynecology Department, Peking University First Hospital, Beijing, 100034, PR China
| | - Juntao Liu
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Shuai Sun
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Fanli Kong
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Shihong Xu
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yuchuan Dai
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Jingyu Xie
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Hongyan Jin
- Obstetrics and Gynecology Department, Peking University First Hospital, Beijing, 100034, PR China
| | - Xinxia Cai
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100094, PR China.,School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| |
Collapse
|
5
|
Smartphone assisted portable biochip for non-invasive simultaneous monitoring of glucose and insulin towards precise diagnosis of prediabetes/diabetes. Biosens Bioelectron 2022; 209:114251. [DOI: 10.1016/j.bios.2022.114251] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 03/25/2022] [Accepted: 04/01/2022] [Indexed: 12/14/2022]
|
6
|
Liu C, Chu D, Kalantar‐Zadeh K, George J, Young HA, Liu G. Cytokines: From Clinical Significance to Quantification. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2004433. [PMID: 34114369 PMCID: PMC8336501 DOI: 10.1002/advs.202004433] [Citation(s) in RCA: 174] [Impact Index Per Article: 58.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 03/26/2021] [Indexed: 05/24/2023]
Abstract
Cytokines are critical mediators that oversee and regulate immune and inflammatory responses via complex networks and serve as biomarkers for many diseases. Quantification of cytokines has significant value in both clinical medicine and biology as the levels provide insights into physiological and pathological processes and can be used to aid diagnosis and treatment. Cytokines and their clinical significance are introduced from the perspective of their pro- and anti-inflammatory effects. Factors affecting cytokines quantification in biological fluids, native levels in different body fluids, sample processing and storage conditions, sensitivity to freeze-thaw, and soluble cytokine receptors are discussed. In addition, recent advances in in vitro and in vivo assays, biosensors based on different signal outputs and intracellular to extracellular protein expression are summarized. Various quantification platforms for high-sensitivity and reliable measurement of cytokines in different scenarios are discussed, and commercially available cytokine assays are compared. A discussion of challenges in the development and advancement of technologies for cytokine quantification that aim to achieve real-time multiplex cytokine analysis for point-of-care situations applicable for both biomedical research and clinical practice are discussed.
Collapse
Affiliation(s)
- Chao Liu
- School of Materials Science and EngineeringUniversity of New South WalesSydneyNSW2052Australia
| | - Dewei Chu
- School of Materials Science and EngineeringUniversity of New South WalesSydneyNSW2052Australia
| | | | - Jacob George
- Storr Liver CentreWestmead Institute of Medical ResearchUniversity of Sydney and Department of Gastroenterology and HepatologyWestmead HospitalWestmeadNSW2145Australia
| | - Howard A. Young
- Laboratory of Cancer ImmunometabolismCenter for Cancer ResearchNational Cancer Institute at FrederickFrederickMD21702USA
| | - Guozhen Liu
- School of Life and Health SciencesThe Chinese University of Hong KongShenzhen518172P. R. China
- Graduate School of Biomedical EngineeringUniversity of New South WalesSydneyNSW2052Australia
| |
Collapse
|
7
|
Jamaludeen N, Beyer C, Billing U, Vogel K, Brunner-Weinzierl M, Spiliopoulou M. Potential of Point-of-Care and At-Home Assessment of Immune Status via Rapid Cytokine Detection and Questionnaire-Based Anamnesis. SENSORS (BASEL, SWITZERLAND) 2021; 21:4960. [PMID: 34372196 PMCID: PMC8348245 DOI: 10.3390/s21154960] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/30/2021] [Accepted: 07/07/2021] [Indexed: 12/29/2022]
Abstract
Monitoring the immune system's status has emerged as an urgent demand in critical health conditions. The circulating cytokine levels in the blood reflect a thorough insight into the immune system status. Indeed, measuring one cytokine may deliver more information equivalent to detecting multiple diseases at a time. However, if the reported cytokine levels are interpreted with considering lifestyle and any comorbid health conditions for the individual, this will promote a more precise assessment of the immune status. Therefore, this study addresses the most recent advanced assays that deliver rapid, accurate measuring of the cytokine levels in human blood, focusing on add-on potentials for point-of-care (PoC) or personal at-home usage, and investigates existing health questionnaires as supportive assessment tools that collect all necessary information for the concrete analysis of the measured cytokine levels. We introduced a ten-dimensional featuring of cytokine measurement assays. We found 15 rapid cytokine assays with assay time less than 1 h; some could operate on unprocessed blood samples, while others are mature commercial products available in the market. In addition, we retrieved several health questionnaires that addressed various health conditions such as chronic diseases and psychological issues. Then, we present a machine learning-based solution to determine what makes the immune system fit. To this end, we discuss how to employ topic modeling for deriving the definition of immune fitness automatically from literature. Finally, we propose a prototype model to assess the fitness of the immune system through leveraging the derived definition of the immune fitness, the cytokine measurements delivered by a rapid PoC immunoassay, and the complementary information collected by the health questionnaire about other health factors. In conclusion, we discovered various advanced rapid cytokine detection technologies that are promising candidates for point-of-care or at-home usage; if paired with a health status questionnaire, the assessment of the immune system status becomes solid and we demonstrated potentials for promoting the assessment tool with data mining techniques.
Collapse
Affiliation(s)
- Noor Jamaludeen
- Knowledge Management & Discovery Lab, Otto-von-Guericke University, 39106 Magdeburg, Germany; (C.B.); (M.S.)
| | - Christian Beyer
- Knowledge Management & Discovery Lab, Otto-von-Guericke University, 39106 Magdeburg, Germany; (C.B.); (M.S.)
| | - Ulrike Billing
- Department of Experimental Pediatrics, University Hospital, Otto-von-Guericke University, 39120 Magdeburg, Germany; (U.B.); (K.V.); (M.B.-W.)
| | - Katrin Vogel
- Department of Experimental Pediatrics, University Hospital, Otto-von-Guericke University, 39120 Magdeburg, Germany; (U.B.); (K.V.); (M.B.-W.)
| | - Monika Brunner-Weinzierl
- Department of Experimental Pediatrics, University Hospital, Otto-von-Guericke University, 39120 Magdeburg, Germany; (U.B.); (K.V.); (M.B.-W.)
| | - Myra Spiliopoulou
- Knowledge Management & Discovery Lab, Otto-von-Guericke University, 39106 Magdeburg, Germany; (C.B.); (M.S.)
| |
Collapse
|
8
|
Liu G, Jiang C, Lin X, Yang Y. Point-of-care detection of cytokines in cytokine storm management and beyond: Significance and challenges. VIEW 2021; 2:20210003. [PMID: 34766163 PMCID: PMC8242812 DOI: 10.1002/viw.20210003] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/01/2021] [Accepted: 03/08/2021] [Indexed: 12/16/2022] Open
Abstract
Cytokines are signaling molecules between cells in immune system. Cytokine storm, due to the sudden acute increase in levels of pro‐inflammatory circulating cytokines, can result in disease severity and major‐organ damage. Thus, there is urgent need to develop rapid, sensitive, and specific methods for monitoring of cytokines in biology and medicine. Undoubtedly, point‐of‐care testing (POCT) will provide clinical significance in disease early diagnosis, management, and prevention. This review aims to summarize and discuss the latest technologies for detection of cytokines with a focus on POCT. The overview of diseases resulting from imbalanced cytokine levels, such as COVID‐19, sepsis and other cytokine release syndromes are presented. The clinical cut‐off levels of cytokine as biomarkers for different diseases are summarized. The challenges and perspectives on the development of cytokine POCT devices are also proposed and discussed. Cytokine POCT devices are expected to be the ongoing spotlight of disease management and prevention during COVID‐19 pandemic and also the post COVID‐19 pandemic era.
Collapse
Affiliation(s)
- Guozhen Liu
- School of Life and Health Sciences The Chinese University of Hong Kong Shenzhen 518172 P.R. China.,Graduate School of Biomedical Engineering University of New South Wales Sydney NSW 2052 Australia
| | - Cheng Jiang
- Nuffield Department of Clinical Neurosciences John Radcliffe Hospital University of Oxford Oxford OX3 9DU United Kingdom
| | - Xiaoting Lin
- Graduate School of Biomedical Engineering University of New South Wales Sydney NSW 2052 Australia
| | - Yang Yang
- School of Life and Health Sciences The Chinese University of Hong Kong Shenzhen 518172 P.R. China
| |
Collapse
|
9
|
Atar N, Yola ML. A novel QCM immunosensor development based on gold nanoparticles functionalized sulfur-doped graphene quantum dot and h-ZnS-CdS NC for Interleukin-6 detection. Anal Chim Acta 2021; 1148:338202. [DOI: 10.1016/j.aca.2021.338202] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 12/25/2020] [Accepted: 01/03/2021] [Indexed: 02/08/2023]
|
10
|
Baharfar M, Rahbar M, Tajik M, Liu G. Engineering strategies for enhancing the performance of electrochemical paper-based analytical devices. Biosens Bioelectron 2020; 167:112506. [PMID: 32823207 DOI: 10.1016/j.bios.2020.112506] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 08/07/2020] [Accepted: 08/07/2020] [Indexed: 12/15/2022]
Abstract
Applications of electrochemical detection methods in microfluidic paper-based analytical devices (μPADs) has revolutionized the area of point-of-care (POC) testing towards highly sensitive and selective quantification of various (bio)chemical analytes in a miniaturized, low-coat, rapid, and user-friendly manner. Shortly after the initiation, these relatively new modulations of μPADs, named as electrochemical paper-based analytical devices (ePADs), gained widespread popularity within the POC research community thanks to the inherent advantages of both electrochemical sensing and usage of paper as a suitable substrate for POC testing platforms. Even though general aspects of ePADs such as applications and fabrication techniques, have already been reviewed multiple times in the literature, herein, we intend to provide a critical engineering insight into the area of ePADs by focusing particularly on the practical strategies utilized to enhance their analytical performance (i.e. sensitivity), while maintaining the desired simplicity and efficiency intact. Basically, the discussed strategies are driven by considering the parameters potentially affecting the generated electrochemical signal in the ePADs. Some of these parameters include the type of filter paper, electrode fabrication methods, electrode materials, fluid flow patterns, etc. Besides, the limitations and challenges associated with the development of ePADs are discussed, and further insights and directions for future research in this field are proposed.
Collapse
Affiliation(s)
- Mahroo Baharfar
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Mohammad Rahbar
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Mohammad Tajik
- School of Chemistry, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Guozhen Liu
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia.
| |
Collapse
|
11
|
The BXD21/TyJ recombinant inbred strain as a model for innate inflammatory response in distinct brain regions. Sci Rep 2020; 10:13168. [PMID: 32759955 PMCID: PMC7406506 DOI: 10.1038/s41598-020-70213-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 07/23/2020] [Indexed: 01/31/2023] Open
Abstract
Oxidative stress and inflammatory cytokines affect the human brain, increasing the risk for mood and cognitive disorders. Such risk might be selective to brain-specific regions. Here, we determined whether BXD recombinant inbred (RI) mice strains are more suitable than C57BL/6J mice for the understanding of the relationship between antioxidant response and inflammatory responses. We hypothesized that inflammatory responses could be independent of antioxidant response and be inherent to brain-specific regions. This hypothesis will be addressed by the analyses of mRNA expression. We explored, at 7-months-of-age, the innate activation of proinflammatory cytokines (tumor necrosis factor alpha (TNFα) and interleukin 6 (IL-6), as well as Kelch-like ECH-associating protein 1 (Keap1), nuclear factor erythroid 2 related factor 2 (Nrf2) and glutathione peroxidase 1 (Gpx1) mRNA in both male and female BXD84/RwwJ RI, BXD21/TyJ RI and control strain (C57BL/6J mice). We report that: (1) The cerebellum is more sensitive to antioxidant response in the BXD21/TyJ RI strain; (2) The cerebellum, hippocampus and striatum show increased levels of cytokines in the BXD21/TyJ RI strain; (3) The BXD RI strain has lower brain weight relative to control strain (C57BL/6 mice). In conclusion, our novel data show the utility of the BXD21/TyJ RI strain mice in offering mechanistic insight into Nrf2's role in the inflammatory system.
Collapse
|
12
|
Qiao L, Benzigar MR, Subramony JA, Lovell NH, Liu G. Advances in Sweat Wearables: Sample Extraction, Real-Time Biosensing, and Flexible Platforms. ACS APPLIED MATERIALS & INTERFACES 2020; 12:34337-34361. [PMID: 32579332 DOI: 10.1021/acsami.0c07614] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Wearable biosensors for sweat-based analysis are gaining wide attention due to their potential use in personal health monitoring. Flexible wearable devices enable sweat analysis at the molecular level, facilitating noninvasive monitoring of physiological states via real-time monitoring of chemical biomarkers. Advances in sweat extraction technology, real-time biosensors, stretchable materials, device integration, and wireless digital technologies have led to the development of wearable sweat-biosensing devices that are light, flexible, comfortable, aesthetic, affordable, and informative. Herein, we summarize recent advances of sweat wearables from the aspects of sweat extraction, fabrication of stretchable biomaterials, and design of biosensing modules to enable continuous biochemical monitoring, which are essential for a biosensing device. Key chemical components of sweat, sweat capture methodologies, and considerations of flexible substrates for integrating real-time biosensors with electronics to bring innovations in the art of wearables are elaborated. The strategies and challenges involved in improving the wearable biosensing performance and the perspectives for designing sweat-based wearable biosensing devices are discussed.
Collapse
Affiliation(s)
- Laicong Qiao
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Mercy Rose Benzigar
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - J Anand Subramony
- Antibody Discovery and Protein Engineering, BioPharmaceuticals R&D, AstraZeneca, Gaithersburg, Maryland 20878, United States
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Guozhen Liu
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| |
Collapse
|