Li X. Changes in corneal biomechanics in patients with glaucoma: a systematic review and meta-analysis. BMC Ophthalmol 2024; 24:168. [PMID: 38622519 PMCID: PMC11017643 DOI: 10.1186/s12886-024-03443-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 04/09/2024] [Indexed: 04/17/2024] Open
Abstract
INTRODUCTION Corneal biomechanics has been implicated in a variety of ocular diseases. The purpose of this study was to evaluate the relationship between the glaucoma and corneal biomechanical properties, and exploring the value of corneal biomechanics in the diagnosis and follow-up of glaucoma diseases. METHODS We searched studies in PubMed, EMBASE, Web of Science and clinicaltrials.gov., as of October 8, 2022. Only English studies were included, without publication time limit. We also searched the reference lists of published reviews. This meta-analysis was conducted with random-effects models, we used mean difference(MD) to evaluate the outcome, and the heterogeneity was assessed with the I2 statistic. Subgroup analyses were performed under the appearance of high heterogeneity. We used 11 items to describe the characteristics of included studies, publication bias was performed through the Egger's test. The quality assessment were evaluated by Newcastle-Ottawa Scale(NOS) items. RESULTS A total of 27 eligible studies were identified for data synthesis and assessment. The result of meta-analysis showed that in the comparison of included indicators, the corneal biomechanics values of glaucoma patients were statistically lower than those of normal subjects in a similar age range. The covered indicators included central corneal thickness(CCT) (MD = -8.34, 95% CI: [-11.74, -4.94]; P < 0.001), corneal hysteresis(CH)(MD = -1.54, 95% CI: [-1.88, -1.20]; P < 0.001), corneal resistance factor(CRF)( MD = -0.82, 95% CI: [-1.21, -0.44]; P < 0.001), and intraocular pressure(IOP)( corneal-compensated intraocular pressure (IOPcc): MD = 2.45, 95% CI: [1.51, 3.38]; P < 0.001); Goldmann-correlated intraocular pressure (IOPg): MD = 1.30, 95% CI: [0.41, 2.20]; P = 0.004), they all showed statistical difference. While the value of axial length(AL) did not show statistically different(MD = 0.13, 95% CI: [-0.24, 0.50]; P = 0.48). CONCLUSION Corneal biomechanics are associated with glaucoma. The findings can be useful for the design of glaucoma screening, treatment and prognosis.
Collapse
Affiliation(s)
- Xinru Li
- Department of Ophthalmology, The First People's Hospital of Yongkang Affiliated to Hangzhou Medical College, Yongkang, 321300, Zhejiang, P. R. China.
| |
Collapse
|
2
|
Vinod K, Salim S. Addressing Glaucoma in Myopic Eyes: Diagnostic and Surgical Challenges. Bioengineering (Basel) 2023; 10:1260. [PMID: 38002384 PMCID: PMC10669452 DOI: 10.3390/bioengineering10111260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 10/23/2023] [Accepted: 10/27/2023] [Indexed: 11/26/2023] Open
Abstract
Epidemiological and genetic studies provide strong evidence supporting an association between myopia and glaucoma. The accurate detection of glaucoma in myopic eyes, especially those with high myopia, remains clinically challenging due to characteristic morphologic features of the myopic optic nerve in addition to limitations of current optic nerve imaging modalities. Distinguishing glaucoma from myopia is further complicated by overlapping perimetric findings. Therefore, longitudinal follow-up is essential to differentiate progressive structural and functional abnormalities indicative of glaucoma from defects that may result from myopia alone. Highly myopic eyes are at increased risk of complications from traditional incisional glaucoma surgery and may benefit from newer microinvasive glaucoma surgeries in select cases.
Collapse
Affiliation(s)
- Kateki Vinod
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai, New York Eye and Ear Infirmary of Mount Sinai, New York, NY 10003, USA
| | - Sarwat Salim
- Department of Ophthalmology, Tufts University School of Medicine, Boston, MA 02116, USA
| |
Collapse
|
3
|
Elhusseiny AM, Scarcelli G, Saeedi OJ. Corneal Biomechanical Measures for Glaucoma: A Clinical Approach. Bioengineering (Basel) 2023; 10:1108. [PMID: 37892838 PMCID: PMC10604716 DOI: 10.3390/bioengineering10101108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/11/2023] [Accepted: 09/14/2023] [Indexed: 10/29/2023] Open
Abstract
Over the last two decades, there has been growing interest in assessing corneal biomechanics in different diseases, such as keratoconus, glaucoma, and corneal disorders. Given the interaction and structural continuity between the cornea and sclera, evaluating corneal biomechanics may give us further insights into the pathogenesis, diagnosis, progression, and management of glaucoma. Therefore, some authorities have recommended baseline evaluations of corneal biomechanics in all glaucoma and glaucoma suspects patients. Currently, two devices (Ocular Response Analyzer and Corneal Visualization Schiempflug Technology) are commercially available for evaluating corneal biomechanics; however, each device reports different parameters, and there is a weak to moderate agreement between the reported parameters. Studies are further limited by the inclusion of glaucoma subjects taking topical prostaglandin analogues, which may alter corneal biomechanics and contribute to contradicting results, lack of proper stratification of patients, and misinterpretation of the results based on factors that are confounded by intraocular pressure changes. This review aims to summarize the recent evidence on corneal biomechanics in glaucoma patients and insights for future studies to address the current limitations of the literature studying corneal biomechanics.
Collapse
Affiliation(s)
- Abdelrahman M. Elhusseiny
- Department of Ophthalmology, Harvey and Bernice Jones Eye Institute, University of Arkansas for Medical Sciences, Little Rock, AR 72205, USA;
- Department of Ophthalmology, Boston Children’s Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA;
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Osamah J. Saeedi
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA;
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| |
Collapse
|
4
|
Fukuoka H, Nishita Y, Tange C, Otsuka R, Ando F, Shimokata H. Basal ganglia lesions may be a risk factor for characteristic features of a glaucomatous optic disc: population-based cohort study in Japan. BMJ Open Ophthalmol 2023. [DOI: 10.1136/bmjophth-2022-001077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2023] Open
Abstract
BackgroundWe conducted a study to investigate the relationship between optic nerve vertical cup-to-disc ratio (VCDR), body and ocular parameters, and brain lesions in middle-aged and above Japanese subjects, because although various risk factors for glaucoma have been previously characterised, it is theorised that there are unidentified neurological components.MethodsIn this population-based, age/gender-stratified, cross-sectional study that involved 2239 Japanese subjects (1127 men and 1112 women) aged 40 years and older (mean age: 59.3±11.7 years) living in the central geographical region of Japan who participated in the National Institute of Longevity Sciences–Longitudinal Study of Aging between 2002 and 2004, 4327 eyes and 2239 obtained MRIs of the head were evaluated. Multivariate mixed model and trend analyses were also performed.ResultsNo significant relationship between VCDR and brain lesions, other than basal ganglia lesions, was found. VCDR significantly increased with the high grade of basal ganglia infarct lesions (p=0.0193) and high intraocular pressure (p<0.0001) after adjustment for influential factors using a multivariate mixed model. A significant positive linear trend was observed between the predicted VCDR and the degrees of the basal ganglia lesions (p value trend=0.0096).ConclusionOur findings suggest that in subjects with higher grades of basal ganglia lesions, strict attention should be paid to elevated VCDR; however, further studies are needed to support/confirm our results.
Collapse
|
5
|
Lotfy A, Mattout HK, Fouda SM, Hemeda S. Correlation between radial peripapillary vascular density and reduced central corneal thickness in glaucoma suspect patients. BMC Ophthalmol 2022; 22:414. [PMID: 36316681 PMCID: PMC9620628 DOI: 10.1186/s12886-022-02628-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 09/29/2022] [Accepted: 10/04/2022] [Indexed: 11/27/2022] Open
Abstract
Background Optical coherence tomography (OCT) angiography (OCTA) provides a quantitative assessment of the microcirculation of the retina and choroid. It may precede the retinal nerve layer (RNFL) and optic disc head defects. Retinal nerve fiber layer defects and reduced central corneal thickness (CCT) are important parameters in the assessment of a glaucoma suspect patients. The aim of this study is to investigate any possible relationship between the reduced central corneal thickness and the radial peripapillary capillary (RPC) density defect in glaucoma suspect. Methods In this cross sectional study, 92 eyes were incorporated. Peripapillary OCT angiography (4.5 mm) and Anterior segment OCT for corneal pachymetry were done. C/D Ratio, thickness of nerve fiber layer, the blood flow indices and central corneal thickness also were evaluated. Results In eyes of glaucoma suspect patients; a significant positive correlation between CCT and total RPC density was detected (r = 0.38, P < 0.001). A strong positive correlation was also found between total RPC and peripapillary RNFL thickness (r = 0.55, P < 0.001). Conclusion Reduced central corneal thickness and peripapillary capillary density are two screening parameters for glaucoma suspect patients. The radial peripapillary capillary density is a valid diagnostic tool for glaucoma. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-022-02628-z.
Collapse
Affiliation(s)
- Ayman Lotfy
- grid.31451.320000 0001 2158 2757Zagazig University, Zagazig, Egypt
| | | | | | - Sahar Hemeda
- grid.31451.320000 0001 2158 2757Zagazig University, Zagazig, Egypt
| |
Collapse
|
6
|
Corneal Hysteresis, Intraocular Pressure, and Progression of Glaucoma: Time for a “Hyst-Oric” Change in Clinical Practice? J Clin Med 2022; 11:jcm11102895. [PMID: 35629021 PMCID: PMC9148097 DOI: 10.3390/jcm11102895] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 05/14/2022] [Accepted: 05/15/2022] [Indexed: 12/04/2022] Open
Abstract
It is known that as people age their tissues become less compliant and the ocular structures are no different. Corneal Hysteresis (CH) is a surrogate marker for ocular compliance. Low hysteresis values are associated with optic nerve damage and visual field loss, the structural and functional components of glaucomatous optic neuropathy. Presently, a range of parameters are measured to monitor and stratify glaucoma, including intraocular pressure (IOP), central corneal thickness (CCT), optical coherence tomography (OCT) scans of the retinal nerve fibre layer (RNFL) and the ganglion cell layer (GCL), and subjective measurement such as visual fields. The purpose of this review is to summarise the current evidence that CH values area risk factor for the development of glaucoma and are a marker for its progression. The authors will explain what precisely CH is, how it can be measured, and the influence that medication and surgery can have on its value. CH is likely to play an integral role in glaucoma care and could potentially be incorporated synergistically with IOP, CCT, and visual field testing to establish risk stratification modelling and progression algorithms in glaucoma management in the future.
Collapse
|
7
|
Thinner Central Corneal Thickness is Associated with a Decreased Parapapillary Vessel Density in Normal Tension Glaucoma. J Ophthalmol 2022; 2022:1937431. [PMID: 35378886 PMCID: PMC8976629 DOI: 10.1155/2022/1937431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 03/09/2022] [Accepted: 03/10/2022] [Indexed: 11/18/2022] Open
Abstract
This retrospective cross-sectional study, which enrolled 124 normal tension glaucoma (NTG) eyes and 68 healthy eyes as the control, determined the association between central corneal thickness (CCT) and ocular parameters in NTG. CCT was measured using the Pentacam® system, optical coherence tomography angiography (OCT-A) was adopted to measure the peripapillary and macular area VDs, and spatial data were based on the Garway–Heath map as illustrated in OCT-A. Univariate and multivariate linear regressions were used to statistically analyze for associations between CCT and other factors. In this study, the mean age was similar for both the NTG and control groups. The mean CCT of the NTG group was significantly thinner than that of the control group (533.97 ± 33.11 µm vs. 546.78 ± 38.21 µm;
= .022). Considering all the factors, CCT negatively correlated with visual field (VF) pattern standard deviation (univariate,
= .045). To analyze structural and functional factors separately, we found a significant positive correlation between CCT and whole disc radial peripapillary capillary VD (VDRPC; multivariate,
= .019). To analyze the relationship between all factors and sectoral changes in VDRPC, a significant positive correlation was observed between CCT and inferior temporal VDRPC (univariate,
= .039) and inferior nasal VDRPC (VDRPC IN; univariate,
= .048). In conclusion, this novel study shows that among NTG participants, a thinner cornea correlated with weaker biomechanical properties susceptible to optic nerve tissue displacement, especially in response to mild transient elevation of IOP, leads to compromised ocular microcirculation.
Collapse
|
8
|
Morales-Fernandez L, Saenz-Frances F, Pérez-García P, Garcia-Feijoo J, Garcia-Saenz S, Gómez de Liaño R, Martinez-de-la-Casa JM. Effects of Corneal Biomechanical Properties on Rebound Tonometry (Icare200) and Applanation Tonometry (Perkins) Readings in Patients With Primary Congenital Glaucoma. J Glaucoma 2022; 31:183-190. [PMID: 34255756 DOI: 10.1097/ijg.0000000000001913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Accepted: 06/13/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The aim was to assess the influence of corneal biomechanics on intraocular pressure (IOP) measurements made with the Icare200 (IC200) rebound tonometer and the Perkins handheld applanation tonometer in patients with primary congenital glaucoma (PCG). MATERIALS AND METHODS A total of 40 PCG patients and 40 healthy controls, age, and sex-matched, were recruited. IOP was measured with the Ocular Response Analyzer (IOPc, IOPg), IC200 and Perkins. The variables age, IOP, corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CCT), best-corrected visual acuity, spherical equivalent, medications, and glaucoma surgeries were recorded for each subject. Univariate and multivariate analysis were used to detect effects of variables on IOP measurements. RESULTS Mean CCT was 545.65±71.88 μm in PCG versus 558.78±27.58 μm in controls (P=0.284). CH and CRF were significantly lower in PCG group than in control group: mean CH 8.11±1.69 versus 11.15±1.63 mm Hg (P<0.001), and mean CRF 9.27±2.35 versus 10.71±1.75 mm Hg (P=0.002). Mean differences between IOP IC200-Perkins were 0.79±0.53 mm Hg in PCG versus 0.80±0.23 mm Hg in controls (P<0.001) and mean differences IC200-IOPc were -0.89±5.15 mm Hg in PCG (P<0.001) versus 1.60±3.03 mm Hg in controls (all P<0.009). Through multivariate analysis, CRF showed positive association and CH negative association with IOP measured with Perkins or IC200 in both subject groups. No association was detected for CCT, age, or sex. CONCLUSION CH and CRF were identified as the main factors interfering with IOP measurements made with both tonometers in patients with PCG and healthy controls.
Collapse
Affiliation(s)
- Laura Morales-Fernandez
- Ophthalmology Unit, Hospital Clinico San Carlos, Madrid, Spain
- Hospital Universitario Quiron Pozuelo
| | | | | | - Julian Garcia-Feijoo
- Ophthalmology Unit, Hospital Clinico San Carlos, Madrid, Spain
- Institute "Investigaciones Oftalmologicas Ramon Castroviejo", University Complutense
- Cooperative Research Network on Age-Related Ocular Disease, and Visual and Life Quality, Instituto de Salud Carlos III, Madrid, Spain
| | | | - Rosario Gómez de Liaño
- Ophthalmology Unit, Hospital Clinico San Carlos, Madrid, Spain
- Institute "Investigaciones Oftalmologicas Ramon Castroviejo", University Complutense
- Cooperative Research Network on Age-Related Ocular Disease, and Visual and Life Quality, Instituto de Salud Carlos III, Madrid, Spain
| | - Jose M Martinez-de-la-Casa
- Ophthalmology Unit, Hospital Clinico San Carlos, Madrid, Spain
- Cooperative Research Network on Age-Related Ocular Disease, and Visual and Life Quality, Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
9
|
Qiu Y, Yu J, Tang L, Ren J, Shao M, Li S, Song Y, Cao W, Sun X. Association Between Sex Hormones and Visual Field Progression in Women With Primary Open Angle Glaucoma: A Cross-Sectional and Prospective Cohort Study. Front Aging Neurosci 2022; 13:756186. [PMID: 35002675 PMCID: PMC8741302 DOI: 10.3389/fnagi.2021.756186] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 12/02/2021] [Indexed: 11/15/2022] Open
Abstract
Purpose: We evaluated the level of sex hormones in female patients with primary open angle glaucoma (POAG) to determine whether they are associated with the onset and/or progression of POAG. Methods: The cross-sectional study enrolled 63 women with POAG and 56 healthy women as normal control subjects. Furthermore, 57 women with POAG were included and followed-up for at least 2 years in the cohort study. All subjects were evaluated for serum concentration of sex hormones [prolactin (PRL), luteinizing hormone (LH), testosterone (TESTO), follicle-stimulating hormone (FSH), progesterone (PROG), and estrogen (E2)] and underwent visual field (VF) examination. In the cross-sectional study, Spearman analysis, linear regression analysis, and logistic regression analysis were performed to assess risk factors for POAG in women. In the cohort study, Cox regression analyses and Kaplan–Meier survival analysis were performed to identify factors associated with VF progression in women with POAG. Results: In the cross-sectional study, the level of E2 was significantly lower in the POAG group than in the normal group (p < 0.05). Multiple logistic regression showed that the decreased level of E2 was a risk factor of POAG (OR = 0.27, 95% CI = 0.09–0.78, p < 0.05), especially in premenopausal subjects. In the cohort study, there were 29 non-progression subjects and 28 progression subjects. Patients in the progression group had significantly lower levels of E2 than those in the no progression group (p < 0.01). The decreased level of E2 at baseline was associated with POAG progression (HR = 0.08, 95% CI = 0.02–0.46, p < 0.05), especially in premenopausal subjects. Patients with POAG and with lower baseline E2 levels had significantly lower VF non-progression rates than patients with higher E2 levels (log-rank test p < 0.001), especially premenopausal subjects (log-rank test p < 0.05). Additionally, logistic regression analyses, Cox regression analyses, and Kaplan–Meier survival analysis showed that PROG, LH, FSH, and TESTO were risk factors of POAG and/or significantly associated with POAG progression. Conclusion: A decreased E2 level is a POAG risk factor and is associated with VF progression in women with POAG, especially in premenopausal subjects. Additionally, other sex hormones (PROG, LH, FSH, and TESTO) might also play a role in POAG pathogenesis.
Collapse
Affiliation(s)
- Yichao Qiu
- Clinical Laboratory, Eye & ENT Hospital, Fudan University, Shanghai, China
| | - Jian Yu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
| | - Li Tang
- Clinical Laboratory, Eye & ENT Hospital, Fudan University, Shanghai, China
| | - Jun Ren
- Clinical Laboratory, Eye & ENT Hospital, Fudan University, Shanghai, China
| | - Mingxi Shao
- Clinical Laboratory, Eye & ENT Hospital, Fudan University, Shanghai, China
| | - Shengjie Li
- Clinical Laboratory, Eye & ENT Hospital, Fudan University, Shanghai, China.,Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
| | - Yunxiao Song
- Department of Clinical Laboratory, Shanghai Xuhui Central Hospital, Shanghai, China
| | - Wenjun Cao
- Clinical Laboratory, Eye & ENT Hospital, Fudan University, Shanghai, China.,Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University - Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Xinghuai Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University - Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| |
Collapse
|
10
|
Corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure and their associated factors in the geriatric population, a population-based study. Int Ophthalmol 2022; 42:2085-2092. [PMID: 34981293 DOI: 10.1007/s10792-021-02207-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Accepted: 12/24/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE To determine the distribution of corneal-compensated intraocular pressure (IOPcc), Goldmann-correlated intraocular pressure (IOPg) and their associated factors in a geriatric population. METHODS The present cross-sectional study was performed in individuals above 60 years of age in Tehran, the capital of Iran. The sampling was performed using multi-stage random cluster sampling method. All participants underwent preliminary ocular examinations, and then imaging by Pentacam HR and IOL master 500. Measurement of IOPg, IOPcc, and corneal biomechanical indices including corneal hysteresis (CH) and corneal resistant factor (CRF) was performed in a random sub-sample using ocular response analyzer (ORA). RESULTS The mean IOPg and IOPcc were 16.76 ± 4.71 mmHg and 19.05 ± 4.67 mmHg, respectively. There were no statistically significant differences in both IOPg (p = 0.891) and IOPcc (p = 0.248) between males and females. Based on the multiple linear regression models, both IOPg and IOPcc showed a statistically significant direct relationship with CRF (P < 0.001) and a significant inverse relationship with CH (P < 0.001 for IOPg and IOPcc), anterior chamber angle (ACA) (p = 0.006 for IOPg and p = 0.017 for IOPcc), and spherical equivalent refractive error (p = 0.032 for IOPg and p = 0.046 for IOPcc). CONCLUSION Mean IOPg and IOPcc in the present study were higher compared to most previous studies. Corneal biomechanical indices including CH and CRF, refractive error and anterior chamber angle were independent associated factors of IOPg and IOPcc in the present study. There was no significant relationship between ORA-derived IOP values and CCT.
Collapse
|
11
|
Jung Y, Suh H, Moon JI. Differential impact of prostaglandin analogues on agreement of intraocular pressure measurements obtained by Goldmann applanation, rebound, and noncontact tonometry. BMC Ophthalmol 2021; 21:436. [PMID: 34915877 PMCID: PMC8680149 DOI: 10.1186/s12886-021-02211-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 12/06/2021] [Indexed: 11/29/2022] Open
Abstract
Background To evaluate the effect of topical prostaglandin analogues on agreement of IOP measurements obtained by Goldmann applanation tonometry (GAT), rebound tonometry (RBT), and noncontact tonometry (NCT) in eyes with primary open- angle glaucoma (POAG). Methods Intraocular pressure measurements were obtained using GAT, RBT, and NCT in patients with POAG with or without prostaglandin analogues. The agreement between each tonometry was analysed using Bland-Altman analyses in those with or without prostaglandin analogues. The effect of average IOP on IOP differences was also evaluated. Results Among a total of 86 subjects included in the study, 44 patients were using prostaglandin analogues. The difference in IOP measured by GAT and RBT was marginally greater in those with (GAT-RBT: − 0.94 ± 1.63 mmHg) prostaglandin analogues than in those without (− 0.33 ± 1.22 mmHg, P = 0.06). The difference in IOP measured by GAT and NCT was significantly greater in the prostaglandin group (GAT-NCT: 2.40 ± 2.89 mmHg) than in the group without prostaglandin analogues (0.41 ± 1.63 mmHg, P < 0.01). While there was no significant relationship between the average of all tonometries and the difference between tonometries in those without prostaglandin analogues, both RBT and NCT underestimated IOP relative to GAT at higher IOP in those using prostaglandin analogues. Conclusion Intraocular pressure measured by RBT and NCT was similar to that measured by GAT in those without prostaglandin analogues. RBT overestimated and NCT underestimated IOP compared to GAT in those using prostaglandin analogues.
Collapse
Affiliation(s)
- Younhea Jung
- Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Hyun Suh
- Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Jung Il Moon
- Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
| |
Collapse
|
12
|
Wu N, Chen Y, Yang Y, Sun X. The changes of corneal biomechanical properties with long-term treatment of prostaglandin analogue measured by Corvis ST. BMC Ophthalmol 2020; 20:422. [PMID: 33081750 PMCID: PMC7576693 DOI: 10.1186/s12886-020-01693-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 10/12/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To investigate the corneal biomechanical changes in primary open angle glaucoma (POAG) patients treated with long-term prostaglandin analogue (PGA). METHODS One hundred eleven newly diagnosed POAG patients, including 43 high tension glaucoma (HTG) and 68 normal tension glaucoma (NTG), were measured by Corvis ST to obtain intraocular pressure (IOP), central corneal thickness (CCT) and corneal biomechanical parameters at baseline and at each follow-up visit after initiation of PGA treatment. The follow-up measurements were analyzed by the generalized estimate equation model with an exchangeable correlation structure. Restricted cubic spline was employed to estimate the dose-response relation between follow-up time and corneal biomechanics. RESULTS The mean follow-up time was 10.3 ± 7.02 months. Deformation amplitude (β = -0.0015, P = 0.016), the first applanation velocity (AV1, β = -0.0004, P = 0.00058) decreased and the first applanation time (AT1, β = 0.0089, P < 0.000001) increased statistically significantly with PGA therapy over time after adjusting for age, gender, axial length, corneal curvature, IOP and CCT. In addition, AT1 was lower (7.2950 ± 0.2707 in NTG and 7.5889 ± 0.2873 in HTG, P = 0.00011) and AV1 was greater (0.1478 ± 0.0187 in NTG and 0.1314 ± 0.0191 in HTG, P = 0.00002) in NTG than in HTG after adjusting for confounding factors. CONCLUSIONS Chronic use of PGA probably influences the corneal biomechanical properties directly, which is to make cornea less deformable. Besides, corneas in NTG tended to be more deformable compared to those in HTG with long-term treatment of PGA.
Collapse
Affiliation(s)
- Na Wu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratoy of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China.,Shanghai Key Laboratoy of Visual Impairment and Restoration, Shanghai, 200031, China
| | - Yuhong Chen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China. .,NHC Key Laboratory of Myopia (Fudan University); Key Laboratoy of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China. .,Shanghai Key Laboratoy of Visual Impairment and Restoration, Shanghai, 200031, China.
| | - Yaping Yang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratoy of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China.,Shanghai Key Laboratoy of Visual Impairment and Restoration, Shanghai, 200031, China
| | - Xinghuai Sun
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratoy of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China.,Shanghai Key Laboratoy of Visual Impairment and Restoration, Shanghai, 200031, China.,State Key Laboratory of Medical Neurobiology, Institutes of Brain Science and Collaborative Innovation Center for Brain Science, Fudan University, Shanghai, 200032, China
| |
Collapse
|
13
|
Buckhurst HD, Gilmartin B, Lam A, Cubbidge RP, Logan NS. In vivo measures of anterior scleral resistance in humans with rebound tonometry. Ophthalmic Physiol Opt 2020; 40:472-481. [PMID: 32495401 DOI: 10.1111/opo.12695] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 04/10/2020] [Accepted: 04/14/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE To measure regional variations in anterior scleral resistance (ASR) using a ballistic rebound tonometer (RBT) and examine whether the variations are significantly affected by ethnicity and refractive error (RE). METHODS ASR was measured using a RBT (iCare TA01) following calibration against the biomechanical properties of agarose biogels. Eight scleral regions (nasal, temporal, superior, inferior, inferior-nasal, inferior-temporal, superior-nasal and superior-temporal) were measured at locations 4mm from the limbus. Subjects were 130 young adults comprising three ethnic groups whose RE distributions [MSE (D) ± S.D.] incorporated individuals categorised as without-myopia (NM; MSE ≥ -0.50) and with-myopia (WM; MSE < -0.50); British-White (BW): 26 NM + 0.52 ± 1.15D; 22 WM -3.83 ± 2.89D]; British-South-Asian (BSA): [9 NM + 0.49 ± 1.06D; 11 WM -5.07 ± 3.76D; Hong-Kong-Chinese (HKC): [11 NM + 0.39 ± 0.66D; 49 WM -4.46 ± 2.70D]. Biometric data were compiled using cycloplegic open-field autorefraction and the Zeiss IOLMaster. Two- and three-way repeated measures analysis of variances (anovas) tested regional differences for RBT values across both refractive status and ethnicity whilst stepwise forward multiple linear regression was used as an exploratory test. RESULTS Significant regional variations in ASR were identified for the BW, BSA and HKC (p < 0.001) individuals; superior-temporal region showed the lowest levels of resistance whilst the inferior-nasal region the highest. Compared to the BW and BSA groups, the HKC subjects displayed a significant increase in mean resistance for each respective region (p < 0.001). With the exception of the inferior region, ethnicity was found to be the chief predictor for variation in the scleral RBT values for all other regions. Mean RE group differences were insignificant. CONCLUSIONS The novel application of RBT to the anterior sclera confirm regional variation in ASR. Greater ASR amongst the HKC group than the BW and BSA individuals suggests that ethnic differences in anterior scleral biomechanics may exist.
Collapse
Affiliation(s)
- Hetal D Buckhurst
- Eye and Vision Research Group, School of Health Professions, Faculty of Health, Plymouth University, Plymouth, UK
| | | | - Andrew Lam
- School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong
| | | | - Nicola S Logan
- School of Life & Health Sciences, Aston University, Birmingham, UK
| |
Collapse
|
14
|
Serafino M, Villani E, Lembo A, Rabbiolo G, Specchia C, Trivedi RH, Nucci P. A comparison of Icare PRO and Perkins tonometers in anesthetized children. Int Ophthalmol 2019; 40:19-29. [PMID: 31313069 DOI: 10.1007/s10792-019-01143-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Accepted: 07/06/2019] [Indexed: 11/24/2022]
Abstract
AIM To compare intraocular pressure (IOP) measurements obtained with the Perkins applanation tonometer and Icare PRO (ICP) rebound tonometer in anesthetized aphakic or strabismus children. Furthermore, intra-operator correlation and inter-operator correlation have been evaluated, along with the effects of central corneal thickness (CCT) on IOP measurements. METHODS Seventy children undergoing examination under anesthesia with sevoflurane for aphakic patients and for surgery for strabismus were included. IOP have been measured twice immediately after anesthesia induction with both Perkins applanation tonometer (PAT) and ICP in one eye and by two different operators with both devices in the fellow eye. Furthermore, CCT was measured with ultrasound pachymetry Pacline (Optikon). Agreement between the device measurements has been evaluated using Bland-Altman analyses. Repeatability and reproducibility of the device have been evaluated with intraclass correlation coefficient (ICC) with a value > 0.75 associated with excellent reliability. The relationship between IOP and CCT has been evaluated with Spearman's correlation coefficient r and determination coefficient r2. RESULTS Mean difference in IOP measurements between ICP and PAT was 1.97 mmHg ± 1.23 mmHg (p < 0.05). This difference appeared to be higher in aphakic patients (mean difference 2.15 ± 1.35) than in patients undergoing strabismus surgery (mean difference 1.83 mmHg ± 1.12). Intraclass correlation coefficient (ICC) is used to evaluate repeatability and reproducibility, which are both high for PAT (repeatability 0.96, reproducibility 0.76) compared with ICP (repeatability 0.81, reproducibility 0.70). Correlation coefficient between CCT and IOP is 0.66 for both ICP and PAT. CONCLUSION ICP tends to overestimate IOP compared to PAT. Repeatability and reproducibility are both high for PAT as compared to ICP. A significant correlation between IOP and CCT for both instruments has been demonstrated.
Collapse
Affiliation(s)
- Massimiliano Serafino
- Department of Clinical Sciences and Community Health, Eye Clinic San Giuseppe Hospital, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Multimedica, University of Milan, Via San Vittore, 12, 20123, Milan, Italy
| | - Edoardo Villani
- Department of Clinical Sciences and Community Health, Eye Clinic San Giuseppe Hospital, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Multimedica, University of Milan, Via San Vittore, 12, 20123, Milan, Italy
| | - Andrea Lembo
- Department of Clinical Sciences and Community Health, Eye Clinic San Giuseppe Hospital, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Multimedica, University of Milan, Via San Vittore, 12, 20123, Milan, Italy.
| | - Giovanni Rabbiolo
- Department of Clinical Sciences and Community Health, Eye Clinic San Giuseppe Hospital, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Multimedica, University of Milan, Via San Vittore, 12, 20123, Milan, Italy
| | - Claudia Specchia
- Department of Molecular and Translational Medicine, Brescia and IRCCS Multimedica, University of Brescia, Milan, Italy
| | - Rupal H Trivedi
- Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, SC, USA
| | - Paolo Nucci
- Department of Clinical Sciences and Community Health, Eye Clinic San Giuseppe Hospital, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Multimedica, University of Milan, Via San Vittore, 12, 20123, Milan, Italy
| |
Collapse
|
15
|
The Influence of Corneal Biomechanical Properties on Intraocular Pressure Measurements Using a Rebound Self-tonometer. J Glaucoma 2018; 27:511-518. [DOI: 10.1097/ijg.0000000000000948] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
16
|
Belovay GW, Goldberg I. The thick and thin of the central corneal thickness in glaucoma. Eye (Lond) 2018; 32:915-923. [PMID: 29445115 DOI: 10.1038/s41433-018-0033-3] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Revised: 01/15/2018] [Accepted: 01/17/2018] [Indexed: 11/09/2022] Open
Abstract
Central corneal thickness (CCT) is an important parameter in the assessment of any potential glaucoma patient. While it affects prognosis in ocular hypertension, its value in patients diagnosed with glaucoma is less certain. There are several biological factors and genetic components that may influence glaucoma progression, which have been associated with thinner CCT. The CCT itself can be affected by several factors including ethnicity, age, sex, glaucoma medications, genetics, and the subtype of glaucoma. Besides, there is variability in the measurement of CCT between difference types of devices. These factors need to be considered in the evaluation of glaucoma patients' CCT and its effect on interpretation of intraocular pressure levels and risk stratification.
Collapse
Affiliation(s)
| | - Ivan Goldberg
- Glaucoma Unit, Sydney Eye Hospital, Sydney, Australia.,Discipline of Ophthalmology, University of Sydney, Sydney, Australia.,Eye Associates, Sydney, Australia
| |
Collapse
|
17
|
Relationship between corneal biomechanical properties and structural biomarkers in patients with normal-tension glaucoma: a retrospective study. BMC Ophthalmol 2018; 18:7. [PMID: 29334923 PMCID: PMC5769305 DOI: 10.1186/s12886-018-0673-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2017] [Accepted: 01/04/2018] [Indexed: 11/10/2022] Open
Abstract
Background We evaluated the relationships between corneal biomechanical properties and structural parameters in patients with newly diagnosed, untreated normal-tension glaucoma (NTG). Methods All subjects were evaluated using an Ocular Response Analyzer (ORA) measuring corneal hysteresis (CH) and the corneal resistance factor (CRF). Central corneal thickness (CCT), Goldmann applanation tonometric (GAT) data, axial length, and the spherical equivalent (SE), were also measured. Confocal scanning laser ophthalmoscopy was performed with the aid of a Heidelberg retina tomograph (HRT III). We sought correlations between HRT parameters and different variables including CCT, CH, and the CRF. Multiple linear regression analysis was performed to identify significant associations between corneal biomechanical properties and optic nerve head parameters. Results We enrolled 95 eyes of 95 NTG patients and 93 eyes of 93 normal subjects. CH and the CRF were significantly lower in more advanced glaucomatous eyes (P = 0.001, P = 0.008, respectively). The rim area, rim volume, linear cup-to-disc ratio (LCDR), and mean retinal nerve fiber layer (RNFL) thickness were significantly worse in more advanced glaucomatous eyes (P < 0.001, P < 0.001, P < 0.001, and P = 0.001). CH was directly associated with rim area, rim volume, and mean RNFL thickness (P = 0.012, P = 0.028, and P = 0.043) and inversely associated with LCDR (P = 0.015), after adjusting for age, axial length, CCT, disc area, GAT data, and SE. However, in normal subjects, there were no significant associations between corneal biomechanical properties and HRT parameters. Conclusions A lower CH is significantly associated with a smaller rim area and volume, a thinner RNFL, and a larger LCDR, independent of disc size, corneal thickness, intraocular pressure, and age.
Collapse
|
18
|
Valero B, Fénolland JR, Rosenberg R, Sendon D, Mesnard C, Sigaux M, Giraud JM, Renard JP. Fiabilité et reproductibilité des mesures de la pression intraoculaire par le tonomètre Icare ® Home (modèle TA022) et comparaison avec les mesures au tonomètre à aplanation de Goldmann chez des patients glaucomateux. J Fr Ophtalmol 2017; 40:865-875. [DOI: 10.1016/j.jfo.2017.06.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2017] [Revised: 06/24/2017] [Accepted: 06/30/2017] [Indexed: 10/18/2022]
|
19
|
Jung Y, Park HYL, Yang HJ, Park CK. Characteristics of corneal biomechanical responses detected by a non-contact scheimpflug-based tonometer in eyes with glaucoma. Acta Ophthalmol 2017. [PMID: 28636261 DOI: 10.1111/aos.13466] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
PURPOSE To determine the corneal biomechanical properties in eyes with glaucoma using a non-contact Scheimpflug-based tonometer. METHODS Corneal biomechanical responses were examined using a non-contact Scheimpflug-based tonometer. The tonometer parameters of the normal control group (n = 75) were compared with those of the glaucoma group (n = 136), including an analysis of glaucoma subgroups categorized by visual field loss. RESULTS After adjusting for potential confounding factors, including the intraocular pressure (IOP), central corneal thickness (CCT), age and axial length, the deformation amplitude was smaller in the glaucoma group (1.09 ± 0.02 mm) than in the normal control group (1.12 ± 0.02 mm; p value = 0.031). The deformation amplitude and the deflection amplitude of the severe glaucoma group (1.12 ± 0.02 mm and 0.92 ± 0.01 mm) were significantly greater than that of the early glaucoma group (1.07 ± 0.01 mm and 0.88 ± 0.11 mm, p = 0.006 and p = 0.031), whereas that of the moderate glaucoma group (1.09 ± 0.02 mm and 0.90 ± 0.02 mm) was greater than that of the early glaucoma group, but this difference was not statistically significant. The deformation amplitude showed a negative correlation with the CCT in the normal control group (r = -0.235), with a weaker negative relationship observed in the early glaucoma group (r = -0.099). However, in the moderate and severe glaucoma groups, the deformation amplitude showed a positive relationship with the CCT, showing an inverse relationship. The duration and number of antiglaucomatous eyedrops used had negative correlations with the CCT in eyes with moderate and severe glaucoma. CONCLUSION Overall, the glaucoma group showed significantly less deformable corneas than did the normal controls, even after adjusting for the IOP, CCT, age and axial length. However, there were also differences according to the severity of glaucoma, where the corneal deformation amplitude was greater in the severe glaucoma group compared to the early glaucoma group. The combined effects of stiffening due to glaucoma and increased viscoelastic properties caused by the chronic use of antiglaucomatous eyedrops may have resulted in the present findings.
Collapse
Affiliation(s)
- Younhea Jung
- Department of Ophthalmology and Visual Science; College of Medicine; Seoul St. Mary's Hospital; The Catholic University of Korea; Seoul Korea
| | - Hae-Young L. Park
- Department of Ophthalmology and Visual Science; College of Medicine; Seoul St. Mary's Hospital; The Catholic University of Korea; Seoul Korea
| | - Hee Jung Yang
- Department of Ophthalmology and Visual Science; College of Medicine; Seoul St. Mary's Hospital; The Catholic University of Korea; Seoul Korea
| | - Chan Kee Park
- Department of Ophthalmology and Visual Science; College of Medicine; Seoul St. Mary's Hospital; The Catholic University of Korea; Seoul Korea
| |
Collapse
|
20
|
Kato Y, Nakakura S, Matsuo N, Yoshitomi K, Handa M, Tabuchi H, Kiuchi Y. Agreement among Goldmann applanation tonometer, iCare, and Icare PRO rebound tonometers; non-contact tonometer; and Tonopen XL in healthy elderly subjects. Int Ophthalmol 2017; 38:687-696. [PMID: 28393323 DOI: 10.1007/s10792-017-0518-2] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2016] [Accepted: 04/04/2017] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate the inter-device agreement among the Goldmann applanation tonometer (GAT), iCare and Icare PRO rebound tonometers, non-contact tonometer (NCT), and Tonopen XL tonometer. METHODS Sixty healthy elderly subjects were enrolled. The intraocular pressure (IOP) in each subject's right eye was measured thrice using each of the five tonometers. Intra-device agreement was evaluated by calculating intraclass correlation coefficients (ICCs). Inter-device agreement was evaluated by ICC and Bland-Altman analyses. RESULTS ICCs for intra-device agreement for each tonometer were >0.8. IOP as measured by iCare (mean ± SD, 11.6 ± 2.5 mmHg) was significantly lower (p < 0.05) than that measured by GAT (14.0 ± 2.8 mmHg), NCT (13.6 ± 2.5 mmHg), Tonopen XL (13.7 ± 4.1 mmHg), and Icare PRO (12.6 ± 2.2 mmHg; Bonferroni test). There was no significant difference in mean IOP among GAT, NCT, and Tonopen XL. Regarding inter-device agreement, ICC was lower between Tonopen XL and other tonometers (all ICCs < 0.4). However, ICCs of GAT, iCare, Icare PRO, and NCT showed good agreement (0.576-0.700). The Bland-Altman analysis revealed that the width of the 95% limits of agreement was larger between the Tonopen XL and the other tonometers ranged from 14.94 to 16.47 mmHg. Among the other tonometers, however, the widths of 95% limits of agreement ranged from 7.91 to 9.24 mmHg. CONCLUSION There was good inter-device agreement among GAT, rebound tonometers, and NCT. Tonopen XL shows the worst agreement with the other tonometers; therefore, we should pay attention to its' respective IOP. CLINICAL TRIAL REGISTRATION Japan Clinical Trials Register; number: UMIN000011544.
Collapse
Affiliation(s)
- Yoshitake Kato
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, 68-1 Aboshi Waku, Himeji, 671-1227, Japan
| | - Shunsuke Nakakura
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, 68-1 Aboshi Waku, Himeji, 671-1227, Japan.
| | - Naoko Matsuo
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, 68-1 Aboshi Waku, Himeji, 671-1227, Japan
| | - Kayo Yoshitomi
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, 68-1 Aboshi Waku, Himeji, 671-1227, Japan
| | - Marina Handa
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, 68-1 Aboshi Waku, Himeji, 671-1227, Japan
| | - Hitoshi Tabuchi
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, 68-1 Aboshi Waku, Himeji, 671-1227, Japan
| | - Yoshiaki Kiuchi
- Department of Ophthalmology and Visual Sciences, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima, 734-8551, Japan
| |
Collapse
|
21
|
Abstract
PURPOSE OF REVIEW The purpose of this review is to summarize the role of central corneal thickness (CCT) in the clinical management of a glaucoma patient. RECENT FINDINGS The prognostic value of CCT is well recognized in patients with ocular hypertension. However, its predictive value in other glaucoma suspects and patients with established glaucoma is less certain. Tonometry artefacts can result from variations in CCT. However, an adequately validated correction algorithm for Goldmann applanation tonometry measurements does not exist. Newer methods of tonometry are potentially less influenced by CCT but are limited in their clinical use. There may also be biological and genetic associations between corneal thickness and glaucoma. Demographics, environmental factors, glaucoma treatment and the measurement device used have a significant influence on CCT, and should be considered when interpreting the effect of cornea thickness in patients with glaucoma. New measurements of the biomechanical properties of the cornea are likely to be better approximations of the globe biomechanics than CCT, but these require further evaluation. SUMMARY The clinical significance of CCT is well recognized in the context of glaucoma diagnosis and management, though the extent of its importance remains debatable. Corneal biomechanical properties may be more significantly associated with glaucoma than CCT.
Collapse
|
22
|
Perucho-González L, Sáenz-Francés F, Morales-Fernández L, Martínez-de-la-Casa JM, Méndez-Hernández CD, Santos-Bueso E, Brookes JL, García-Feijoó J. Structural and biomechanical corneal differences between patients suffering from primary congenital glaucoma and healthy volunteers. Acta Ophthalmol 2017; 95:e107-e112. [PMID: 27573413 DOI: 10.1111/aos.13212] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2016] [Accepted: 06/28/2016] [Indexed: 12/18/2022]
Abstract
PURPOSE To determine whether a set of ocular morphometric and biomechanical variables are able to discriminate between healthy volunteers and patients suffering from primary congenital glaucoma (PCG). METHODS Case-control study in which 66 patients with PCG and 94 age-matched healthy subjects were evaluated using ocular response analyser (ORA) to record corneal biomechanical properties. Topographic corneal variables were obtained using the Pentacam in both groups. To determine the ability to discern between both groups, a multivariate binary logistic model was constructed. The outcome was the diagnosis of PCG and the predictors; the corneal variables analysed along with their first-term interactions. Sensitivity and specificity of this model along with the area under the receiver characteristic operating curve (AUC of ROC) were determined. RESULTS The best model to discriminate between both groups included the following predictors: corneal hysteresis (CH), corneal resistance factor (CRF), posterior maximum elevation (PME), anterior maximum elevation (AME) and central corneal thickness (CCT). This model, for a cut-point of 50%, presents a sensitivity of 86.67%, a specificity of 86.89% and an AUC of the ROC curve of 93.16% [95% confidence interval (CI): 88.97-97.35]. The adjusted odds ratios of those predictors which showed a significant discriminating capacity were as follows: for CH, 0.27 (95% confidence interval: 0.15-0.46); for CRF, 2.13 (95% CI: 1.33-3.40); for PME, 1.06 (95% CI: 1.01-1.12); and for AME, 1.35 (95% CI: 1.10-1.66). CONCLUSION Corneal hysteresis (CH), CRF, PME and AME are able to discern between patients with PCG and healthy controls. This fact suggests that there are structural and biomechanical differences between these groups.
Collapse
Affiliation(s)
- Lucía Perucho-González
- Ophthalmology Department; Clinico San Carlos University Hospital; Sanitary Research Institute of the San Carlos Clinical Hospital; Madrid Spain
| | - Federico Sáenz-Francés
- Ophthalmology Department; Clinico San Carlos University Hospital; Sanitary Research Institute of the San Carlos Clinical Hospital; Madrid Spain
| | - Laura Morales-Fernández
- Ophthalmology Department; Clinico San Carlos University Hospital; Sanitary Research Institute of the San Carlos Clinical Hospital; Madrid Spain
| | - José María Martínez-de-la-Casa
- Ophthalmology Department; Clinico San Carlos University Hospital; Sanitary Research Institute of the San Carlos Clinical Hospital; Madrid Spain
| | - Carmen D. Méndez-Hernández
- Ophthalmology Department; Clinico San Carlos University Hospital; Sanitary Research Institute of the San Carlos Clinical Hospital; Madrid Spain
| | - Enrique Santos-Bueso
- Ophthalmology Department; Clinico San Carlos University Hospital; Sanitary Research Institute of the San Carlos Clinical Hospital; Madrid Spain
| | - John L. Brookes
- Glaucoma Department; Moorfields Eye Hospital & Great Ormond Street Hospital for Children; London UK
| | - Julián García-Feijoó
- Ophthalmology Department; Clinico San Carlos University Hospital; Sanitary Research Institute of the San Carlos Clinical Hospital; Madrid Spain
| |
Collapse
|
23
|
Ittoop SM, SooHoo JR, Seibold LK, Mansouri K, Kahook MY. Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring. Adv Ther 2016; 33:1679-1690. [PMID: 27531519 PMCID: PMC5055550 DOI: 10.1007/s12325-016-0388-4] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Indexed: 11/25/2022]
Abstract
Glaucoma is a common optic neuropathy that can lead to irreversible vision loss, and intraocular pressure (IOP) is the only known modifiable risk factor. The primary method of treating glaucoma involves lowering IOP using medications, laser and/or invasive surgery. Currently, we rely on in-office measurements of IOP to assess diurnal variation and to define successful management of disease. These measurements only convey a fraction of a patient’s circadian IOP pattern and may frequently miss peak IOP levels. There is an unmet need for a reliable and accurate device for 24-h IOP monitoring. The 24-h IOP monitoring devices that are currently available and in development fall into three main categories: self-monitoring, temporary continuous monitoring, and permanent continuous monitoring. This article is a systematic review of current and future technologies for measuring IOP over a 24-h period.
Collapse
Affiliation(s)
| | - Jeffrey R SooHoo
- Department of Ophthalmology, University of Colorado School of Medicine, Denver, CO, USA
| | - Leonard K Seibold
- Department of Ophthalmology, University of Colorado School of Medicine, Denver, CO, USA
| | - Kaweh Mansouri
- Department of Ophthalmology, University of Colorado School of Medicine, Denver, CO, USA
- Glaucoma Center, Montchoisi Clinic, Swiss Vision Network, Lausanne, Switzerland
| | - Malik Y Kahook
- Department of Ophthalmology, University of Colorado School of Medicine, Denver, CO, USA
| |
Collapse
|
24
|
Zhang J, Zheng L, Zhao X, Xu Y, Chen S. Corneal biomechanics after small-incision lenticule extraction versus Q-value-guided femtosecond laser-assisted in situ keratomileusis. J Curr Ophthalmol 2016; 28:181-187. [PMID: 27830201 PMCID: PMC5093843 DOI: 10.1016/j.joco.2016.08.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2016] [Revised: 08/02/2016] [Accepted: 08/06/2016] [Indexed: 11/16/2022] Open
Abstract
Purpose The aim of this study was to compare the changes in corneal biomechanical properties following small-incision lenticule extraction (SMILE) versus Q-value–guided femtosecond laser-assisted in situ keratomileusis (Q-FS-LASIK). Methods In this prospective comparative study, patients with a sphere plus cylinder measurement of less than −10.00 D and cylinder measurement of less than −5.00 D were included in the study. A total of 160 patients (160 eyes) with myopia and myopic astigmatism were divided into the two groups, with 80 patients (80 eyes) allocated to SMILE and 80 patients (80 eyes) allocated to Q-FS-LASIK. Corneal hysteresis (CH) and the corneal resistance factor (CRF) were quantitatively assessed using the Ocular Response Analyzer (ORA) preoperatively and at 1 day, 2 weeks, and 1 and 3 months postoperatively. Results Both types of surgery were associated with statistically significant decreases in CH and the CRF at postoperative day 1 (both P < 0.01). In both groups, the decreases subsequently stabilized with no further deteriorations compared to postoperative day 1 (P > 0.05). Both groups showed similar biomechanical changes at each time point (all P > 0.05). Conclusions Both SMILE and Q-FS-LASIK resulted in a decrease in CH and the CRF at postoperative 1 day, with the decreases stabilizing after this point. There were no significant differences between the short term effects of SMILE and Q-FS-LASIK on corneal biomechanical properties.
Collapse
Affiliation(s)
- Jun Zhang
- HangZhou Bright Vision Hospital, ZheJiang Province, China
| | - Li Zheng
- HangZhou Bright Vision Hospital, ZheJiang Province, China
| | - Xia Zhao
- HangZhou Bright Vision Hospital, ZheJiang Province, China
| | - Yang Xu
- HangZhou Bright Vision Hospital, ZheJiang Province, China
| | - Shu Chen
- HangZhou Bright Vision Hospital, ZheJiang Province, China
| |
Collapse
|
25
|
Matsuura M, Hirasawa K, Murata H, Yanagisawa M, Nakao Y, Nakakura S, Kiuchi Y, Asaoka R. The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma. PLoS One 2016; 11:e0161742. [PMID: 27580243 PMCID: PMC5006993 DOI: 10.1371/journal.pone.0161742] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Accepted: 08/10/2016] [Indexed: 11/30/2022] Open
Abstract
It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients with primary open-angle glaucoma. Measurements of CST, ORA, axial length (AL), average corneal curvature (CC), central corneal thickness (CCT) and intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) were carried out. The association between CST and ORA parameters was assessed using linear regression analysis, with model selection based on the second order bias corrected Akaike Information Criterion index. Measurements from ORA (corneal hysteresis [CH] and corneal response factor [CRF]) had high intraclass correlation coefficients (ICC) and low coefficients of variation, but some CST parameters showed much lower reproducibility, namely: A1 length, A2 length, highest concavity time and peak distance. Of 12 CST parameters tested, 8 were significantly correlated with CH and 10 were significantly correlated with CRF, however, the magnitude of the correlation coefficients were weak to moderate at best. The optimal model to explain CH using CST measurements was given by: CH = -76.3 + 4.6*A1 time + 1.9*A2 time + 3.1 * highest concavity deformation amplitude + 0.016*CCT (R2 = 0.67, p <0.001). Similarly, the optimal model for CRF was given by: CRF = -53.5 + 4.2*A1 time + 1.9*A1 length + 20.8*A1 deformation amplitude + 0.8*A2 time + 0.017*CCT (R2 = 0.73, p <0.001). ORA parameters show higher reproducibility than CST measurements. Although many CST parameters are significantly related to ORA parameters, the strengths of these relationships are weak to moderate.
Collapse
Affiliation(s)
- Masato Matsuura
- Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Kazunori Hirasawa
- Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
- Orthoptics and Visual Science, Department of Rehabilitation, School of Allied Health Sciences, Kitasato University, Kanagawa, Japan
| | - Hiroshi Murata
- Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Mieko Yanagisawa
- Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Yoshitaka Nakao
- Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima, Japan
| | - Shunsuke Nakakura
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji, Japan
| | - Yoshiaki Kiuchi
- Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima, Japan
| | - Ryo Asaoka
- Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
- * E-mail:
| |
Collapse
|
26
|
Perucho-González L, Martínez de la Casa JM, Morales-Fernández L, Bañeros-Rojas P, Saenz-Francés F, García-Feijoó J. Intraocular pressure and biomechanical corneal properties measure by ocular response analyser in patients with primary congenital glaucoma. Acta Ophthalmol 2016; 94:e293-7. [PMID: 26647905 DOI: 10.1111/aos.12912] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Accepted: 09/23/2015] [Indexed: 12/25/2022]
Abstract
PURPOSE To measure the differences in corneal hysteresis (CH) and corneal resistance factor (CRF) in primary congenital glaucoma (PCG) and in control subjects using ocular response analyser (ORA) and also to compare intraocular pressure (IOP) measurements given by ORA against IOP given by Perkins tonometer, a handheld version of Goldman applanation tonometer (GAT), to determine correlation. METHODS One hundred and eighteen eyes of 78 patients with PCG (group I) and 103 eyes of 53 controls (group II) were evaluated using ORA. In all participants, IOP was measured using the Perkins tonometer. The ORA device uses applanation pressure peaks to generate the corneal-compensated IOP (IOPcc), which is reportedly independent of corneal thickness, and the measurement of Goldman-correlated IOP (IOPg), which is influenced by corneal thickness. RESULTS The measures in group I were as follows: IOPcc 20.92 ± 5.33; IOPg 18.87 ± 6.67; CH 8.51 ± 2.25; CRF 9.85 ± 3.03; and IOP measured by Goldman 18.32 ± 5.13. The measures in group II were as follows: IOPcc 14.33 ± 2.91; IOPg 14.77 ± 3.00; CH 11.37 ± 1.61; CRF 11.02 ± 1.74; and IOP measured by Goldman 13.74 ± 2.42. The differences of all parameters compared between both groups were statistically significant (p < 0.001 for CH and for all IOP measures and p = 0.001 for CRF). The values of IOPcc, IOPg and IOP measured with Goldman were higher in group I than the values in group II. However, CH and CRF values were lower in group I. CONCLUSION A decrease in CH and CRF has been observed in patients with PCG compared to controls. Future research should assess how these parameters are modified in PCG and whether they could provide more information about progression.
Collapse
|
27
|
|
28
|
Mihailovic N, Termühlen J, Alnawaiseh M, Eter N, Dietlein TS, Rosentreter A. [Ease of handling of first and second generation rebound tonometers]. Ophthalmologe 2015; 113:314-20. [PMID: 26498448 DOI: 10.1007/s00347-015-0153-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the ease of handling of two rebound tonometers, which are designed for self-measurement of intraocular pressure (IOP) in a clinical setting by untrained patients. METHODS After self-measurement of the IOP with the rebound tonometers iCare ONE and iCare HOME, participants were asked to complete a questionnaire containing different subitems concerning ease of operation using a visual analog scale (1 = very good to 5 = very poor). Moreover, the feasibility and duration of measurement were tested. RESULTS A total of 147 subjects participated in this study. The mean score for general handling ability was 2.79 ± 1.01 for the iCare ONE and 1.85 ± 0.87 for the iCare HOME (p < 0.001). The evaluation of the subitems sense of safety (iCare ONE: 2.71 ± 1.03 and iCare HOME: 1.87 ± 0.81, p < 0.001) and comfort of measurement (iCare ONE: 2.07 ± 1.01 and iCare HOME: 1.66 ± 0.72, p < 0.001) also showed a significant discrepancy between the two tonometers. Participants needed significantly less time for a single valid measurement when using the iCare HOME tonometer (mean 66.14 ± 61.54 s) compared to the iCare ONE tonometer (mean 81.54 ± 69.51 s, p < 0.001). CONCLUSIONS A better handling of the iCare HOME rebound tonometer in comparison to the iCare ONE tonometer can be deduced on the basis of the subjective assessments of patients and the shorter duration of measurements. Moreover, the iCare HOME received a significantly better evaluation for all subitems. The accuracy of measurements using the iCare HOME still needs to be clarified.
Collapse
Affiliation(s)
- N Mihailovic
- Klinik für Augenheilkunde, Universitätsklinikum Münster, Münster, Deutschland
| | - J Termühlen
- Klinik für Augenheilkunde, Universitätsklinikum Münster, Münster, Deutschland
| | - M Alnawaiseh
- Klinik für Augenheilkunde, Universitätsklinikum Münster, Münster, Deutschland
| | - N Eter
- Klinik für Augenheilkunde, Universitätsklinikum Münster, Münster, Deutschland
| | - T S Dietlein
- Zentrum für Augenheilkunde, Universitätsklinikum Köln, Köln, Deutschland
| | - A Rosentreter
- Klinik für Augenheilkunde, Universitätsklinikum Münster, Münster, Deutschland.
- Klinik für Augenheilkunde, Universitätsklinikum Würzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Deutschland.
| |
Collapse
|
29
|
Asaoka R, Nakakura S, Tabuchi H, Murata H, Nakao Y, Ihara N, Rimayanti U, Aihara M, Kiuchi Y. The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature. PLoS One 2015; 10:e0140385. [PMID: 26485129 PMCID: PMC4618943 DOI: 10.1371/journal.pone.0140385] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2015] [Accepted: 09/24/2015] [Indexed: 11/25/2022] Open
Abstract
The purpose of the study was to investigate the correlation between Corneal Visualization Scheimpflug Technology (Corvis ST tonometry: CST) parameters and various other ocular parameters, including intraocular pressure (IOP) with Goldmann applanation tonometry. IOP with Goldmann applanation tonometry (IOP-G), central corneal thickness (CCT), axial length (AL), corneal curvature, and CST parameters were measured in 94 eyes of 94 normal subjects. The relationship between ten CST parameters against age, gender, IOP-G, AL, CST-determined CCT and average corneal curvature was investigated using linear modeling. In addition, the relationship between IOP-G versus CST-determined CCT, AL, and other CST parameters was also investigated using linear modeling. Linear modeling showed that the CST measurement ‘A time-1’ is dependent on IOP-G, age, AL, and average corneal curvature; ‘A length-1’ depends on age and average corneal curvature; ‘A velocity-1’ depends on IOP-G and AL; ‘A time-2’ depends on IOP-G, age, and AL; ‘A length-2’ depends on CCT; ‘A velocity-2’ depends on IOP-G, age, AL, CCT, and average corneal curvature; ‘peak distance’ depends on gender; ‘maximum deformation amplitude’ depends on IOP-G, age, and AL. In the optimal model for IOP-G, A time-1, A velocity-1, and highest concavity curvature, but not CCT, were selected as the most important explanatory variables. In conclusion, many CST parameters were not significantly related to CCT, but IOP usually was a significant predictor, suggesting that an adjustment should be made to improve their usefulness for clinical investigations. It was also suggested CST parameters were more influential for IOP-G than CCT and average corneal curvature.
Collapse
Affiliation(s)
- Ryo Asaoka
- Department of Ophthalmology, The University of Tokyo, Tokyo, Japan
| | - Shunsuke Nakakura
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji, Japan
| | - Hitoshi Tabuchi
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji, Japan
| | - Hiroshi Murata
- Department of Ophthalmology, The University of Tokyo, Tokyo, Japan
| | - Yoshitaka Nakao
- Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima Japan
| | - Noriko Ihara
- Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima Japan
| | - Ulfah Rimayanti
- Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima Japan; Faculty of Health Science, UIN Alauddin Makassar, Sulawesi Selatan, Indonesia
| | - Makoto Aihara
- Department of Ophthalmology, The University of Tokyo, Tokyo, Japan
| | - Yoshiaki Kiuchi
- Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima Japan
| |
Collapse
|
30
|
Koprowski R. Automatic method of analysis and measurement of additional parameters of corneal deformation in the Corvis tonometer. Biomed Eng Online 2014; 13:150. [PMID: 25406740 PMCID: PMC4258810 DOI: 10.1186/1475-925x-13-150] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2014] [Accepted: 11/03/2014] [Indexed: 12/03/2022] Open
Abstract
INTRODUCTION The method for measuring intraocular pressure using the Corvis tonometer provides a sequence of images of corneal deformation. Deformations of the cornea are recorded using the ultra-high-speed Scheimpflug camera. This paper presents a new and reproducible method of analysis of corneal deformation images that allows for automatic measurements of new features, namely new three parameters unavailable in the original software. MATERIAL AND METHOD The images subjected to processing had a resolution of 200 × 576 × 140 pixels. They were acquired from the Corvis tonometer and simulation. In total 14,000 2D images were analysed. The image analysis method proposed by the author automatically detects the edge of the cornea and sclera fragments. For this purpose, new methods of image analysis and processing proposed by the author as well as those well-known, such as Canny filter, binarization, median filtering etc., have been used. The presented algorithms were implemented in Matlab (version 7.11.0.584-R2010b) with Image Processing toolbox (version 7.1-R2010b) using both known algorithms for image analysis and processing and those proposed by the author. RESULTS Owing to the proposed algorithm it is possible to determine three parameters: (1) the degree of the corneal reaction relative to the static position; (2) the corneal length changes; (3) the ratio of amplitude changes to the corneal deformation length. The corneal reaction is smaller by about 30.40% compared to its static position. The change in the corneal length during deformation is very small, approximately 1% of its original length. Parameter (3) enables to determine the applanation points with a correlation of 92% compared to the conventional method for calculating corneal flattening areas. The proposed algorithm provides reproducible results fully automatically within a few seconds/per patient using Core i7 processor. CONCLUSIONS Using the proposed algorithm, it is possible to measure new, additional parameters of corneal deformation, which are not available in the original software. The presented analysis method provides three new parameters of the corneal reaction. Detailed clinical studies based on this method will be presented in subsequent papers.
Collapse
Affiliation(s)
- Robert Koprowski
- Department of Biomedical Computer Systems, University of Silesia, Faculty of Computer Science and Materials Science, Institute of Computer Science, ul, Będzińska 39, Sosnowiec 41-200, Poland.
| |
Collapse
|