1
|
Phu J, Khuu SK, Nivison-Smith L, Kalloniatis M. Standard automated perimetry for glaucoma and diseases of the retina and visual pathways: Current and future perspectives. Prog Retin Eye Res 2025; 104:101307. [PMID: 39413870 DOI: 10.1016/j.preteyeres.2024.101307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 10/11/2024] [Accepted: 10/11/2024] [Indexed: 10/18/2024]
Abstract
Static automated perimetry (SAP) remains a mainstay of functional assessment of the visual field in diseases of the visual pathway, such as glaucoma and age-related macular degeneration. The fundamental psychophysical task of responding to stimuli of different levels of contrast has remained minimally changed since its inception in the 1980s, and this is potentially the root of several unresolved issues involving the technique. Enduring issues include the optimisation of SAP parameters for maximising defect detection, the influence of subjective behaviour on the response, structure-function discordance, and ageing- and disease-related changes of the visual pathway. Addressing these issues has been a focus of our research program and is the subject of this manuscript. We will review some of the basic psychophysical principles and methods that have contributed to the development of SAP and their contributions to its output measurements. Parameters that are interrogated include stimulus size and background luminance and their modification to improve defect defection in glaucoma and age-related macular degeneration. We propose frameworks for optimising testing parameters and leveraging the results for changing clinical care. In our pursuit of optimising the structure-function relationship in the eye, several areas of research have been developed and explored, including: the reconciliation of subjective responses in perimetry; by minimising sources of biases, such as Method of Limits we have been able to equate static and kinetic perimetry outputs in relation to underlying structural loci. This also formed the basis for our clustering framework, which groups together statistically similar structural and functional test locations to maximise structure-function concordance. Throughout the manuscript, we review the scientific underpinnings of clinical measurements, framing application into real-world patients to improve clinical practice.
Collapse
Affiliation(s)
- Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia; Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia; Concord Clinical School, Concord Repatriation General Hospital, Concord, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, VIC, Australia.
| | - Sieu K Khuu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia.
| | - Lisa Nivison-Smith
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, VIC, Australia; College of Optometry, University of Houston, Houston, TX, USA.
| |
Collapse
|
2
|
Tong J, Alonso-Caneiro D, Kugelman J, Phu J, Khuu SK, Kalloniatis M. Characterisation of the normal human ganglion cell-inner plexiform layer using widefield optical coherence tomography. Ophthalmic Physiol Opt 2024; 44:457-471. [PMID: 37990841 DOI: 10.1111/opo.13255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 11/02/2023] [Accepted: 11/03/2023] [Indexed: 11/23/2023]
Abstract
PURPOSE To describe variations in ganglion cell-inner plexiform layer (GCIPL) thickness in a healthy cohort from widefield optical coherence tomography (OCT) scans. METHODS Widefield OCT scans spanning 55° × 45° were acquired from 470 healthy eyes. The GCIPL was automatically segmented using deep learning methods. Thickness measurements were extracted after correction for warpage and retinal tilt. Multiple linear regression analysis was applied to discern trends between global GCIPL thickness and age, axial length and sex. To further characterise age-related change, hierarchical and two-step cluster algorithms were applied to identify locations sharing similar ageing properties, and rates of change were quantified using regression analyses with data pooled by cluster analysis outcomes. RESULTS Declines in widefield GCIPL thickness with age, increasing axial length and female sex were observed (parameter estimates -0.053, -0.436 and -0.464, p-values <0.001, <0.001 and 0.02, respectively). Cluster analyses revealed concentric, slightly nasally displaced, horseshoe patterns of age-related change in the GCIPL, with up to four statistically distinct clusters outside the macula. Linear regression analyses revealed significant ageing decline in GCIPL thickness across all clusters, with faster rates of change observed at central locations when expressed as absolute (slope = -0.19 centrally vs. -0.04 to -0.12 peripherally) and percentage rates of change (slope = -0.001 centrally vs. -0.0005 peripherally). CONCLUSIONS Normative variations in GCIPL thickness from widefield OCT with age, axial length and sex were noted, highlighting factors worth considering in further developments. Widefield OCT has promising potential to facilitate quantitative detection of abnormal GCIPL outside standard fields of view.
Collapse
Affiliation(s)
- Janelle Tong
- Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - David Alonso-Caneiro
- School of Science, Technology and Engineering, University of Sunshine Coast, Sunshine Coast, Queensland, Australia
- Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Jason Kugelman
- Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Jack Phu
- Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
- Faculty of Medicine, University of Sydney, Sydney, New South Wales, Australia
- Concord Clinical School, Concord Repatriation General Hospital, Sydney, New South Wales, Australia
- School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| | - Sieu K Khuu
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
- School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| |
Collapse
|
3
|
Uhm SY, Do TP, Montoya RH, Lam B, Kheirkhah A. Comparison of corneal tomographic parameters between Hispanic and non-Hispanic patients. Graefes Arch Clin Exp Ophthalmol 2024; 262:143-148. [PMID: 37493776 DOI: 10.1007/s00417-023-06167-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 05/28/2023] [Accepted: 07/11/2023] [Indexed: 07/27/2023] Open
Abstract
PURPOSE To compare corneal tomographic parameters between Hispanic White and non-Hispanic White patients using Pentacam data. METHODS This retrospective study evaluated preoperative Pentacam data from 641 patients 50 years or older who underwent surgery for senile cataract and self-identified as Hispanic or non-Hispanic White. Patients of non-White race or multiethnic groups, or a history of surgery, trauma, or any abnormality of the cornea or anterior segment were excluded. Cornea and anterior segment parameters, as measured with Pentacam, were then compared between Hispanics and non-Hispanics. RESULTS There were 352 Hispanic White and 289 non-Hispanic White patients. These included 231 men and 410 women, with a mean age of 69.5 ± 8.2 years. There were no significant differences between Hispanics and non-Hispanics in front or back keratometry or amount of front astigmatism. However, Hispanics had a greater amount of back astigmatism (0.36 ± 0.19 vs 0.32 ± 0.17 diopter, P = 0.04). Moreover, there was a statistically significant difference in front steep axis of the left eyes between Hispanics and non-Hispanics (97.8 ± 47.9 vs 108.2 ± 48.9 deg, P = 0.01), and a marginally significant difference in front steep axis of the right eyes (81.0 ± 48.2 vs 73.5 ± 49.9 deg, P = 0.06). Hispanics also had a lower vertex pachymetry (548.1 ± 34.5 vs 553.4 ± 37.4 μm, P = 0.04) and a smaller anterior chamber volume (134.7 ± 39.0 vs 146.1 ± 39.9 mm3, P < 0.001). CONCLUSIONS There are some differences in cornea and anterior segment parameters between Hispanics and non-Hispanics 50 years or older who underwent surgery for senile cataract. However, such differences may not be clinically significant.
Collapse
Affiliation(s)
- So Yeon Uhm
- Department of Ophthalmology, UT Health San Antonio, San Antonio, TX, USA
| | - Trong Phat Do
- Department of Ophthalmology, UT Health San Antonio, San Antonio, TX, USA
| | | | - Brandon Lam
- Department of Ophthalmology, UT Health San Antonio, San Antonio, TX, USA
| | - Ahmad Kheirkhah
- Department of Ophthalmology, UT Health San Antonio, San Antonio, TX, USA.
- Medical Arts and Research Center, 8300 Floyd Curl Dr., San Antonio, TX, USA.
| |
Collapse
|
4
|
Tong J, Phu J, Alonso‐Caneiro D, Khuu SK, Kalloniatis M. High sampling resolution optical coherence tomography reveals potential concurrent reductions in ganglion cell-inner plexiform and inner nuclear layer thickness but not in outer retinal thickness in glaucoma. Ophthalmic Physiol Opt 2023; 43:46-63. [PMID: 36416369 PMCID: PMC10947055 DOI: 10.1111/opo.13065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 10/28/2022] [Accepted: 10/30/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To analyse optical coherence tomography (OCT)-derived inner nuclear layer (INL) and outer retinal complex (ORC) measurements relative to ganglion cell-inner plexiform layer (GCIPL) measurements in glaucoma. METHODS Glaucoma participants (n = 271) were categorised by 10-2 visual field defect type. Differences in GCIPL, INL and ORC thickness were calculated between glaucoma and matched healthy eyes (n = 548). Hierarchical cluster algorithms were applied to generate topographic patterns of retinal thickness change, with agreement between layers assessed using Cohen's kappa (κ). Differences in GCIPL, INL and ORC thickness within and outside GCIPL regions showing the greatest reductions and Spearman's correlations between layer pairs were compared with 10-2 mean deviation (MD) and pattern standard deviation (PSD) to determine trends with glaucoma severity. RESULTS Glaucoma participants with inferior and superior defects presented with concordant GCIPL and INL defects demonstrating mostly fair-to-moderate agreement (κ = 0.145-0.540), which was not observed in eyes with no or ring defects (κ = -0.067-0.230). Correlations (r) with MD and PSD were moderate and weak in GCIPL and INL thickness differences, respectively (GCIPL vs. MD r = 0.479, GCIPL vs. PSD r = -0.583, INL vs. MD r = 0.259, INL vs. PSD r = -0.187, p = <0.0001-0.002), and weak in GCIPL-INL correlations (MD r = 0.175, p = 0.004 and PSD r = 0.154, p = 0.01). No consistent patterns in ORC thickness or correlations were observed. CONCLUSIONS In glaucoma, concordant reductions in macular INL and GCIPL thickness can be observed, but reductions in ORC thickness appear unlikely. These findings suggest that trans-synaptic retrograde degeneration may occur in glaucoma and could indicate the usefulness of INL thickness in evaluating glaucomatous damage.
Collapse
Affiliation(s)
- Janelle Tong
- Centre for Eye HealthUniversity of New South WalesNew South WalesSydneyAustralia
- School of Optometry and Vision ScienceUniversity of New South WalesNew South WalesSydneyAustralia
| | - Jack Phu
- Centre for Eye HealthUniversity of New South WalesNew South WalesSydneyAustralia
- School of Optometry and Vision ScienceUniversity of New South WalesNew South WalesSydneyAustralia
- Faculty of MedicineUniversity of SydneySydneyNew South WalesAustralia
| | - David Alonso‐Caneiro
- Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision ScienceQueensland University of TechnologyBrisbaneQueenslandAustralia
| | - Sieu K. Khuu
- School of Optometry and Vision ScienceUniversity of New South WalesNew South WalesSydneyAustralia
| | - Michael Kalloniatis
- School of Optometry and Vision ScienceUniversity of New South WalesNew South WalesSydneyAustralia
- School of Medicine (Optometry)Deakin UniversityWaurn PondsVictoriaAustralia
| |
Collapse
|
5
|
Tong J, Phu J, Alonso-Caneiro D, Khuu SK, Kalloniatis M. Clinical Evaluations of Macular Structure-Function Concordance With and Without Drasdo Displacement. Transl Vis Sci Technol 2022; 11:18. [PMID: 35438719 PMCID: PMC9034708 DOI: 10.1167/tvst.11.4.18] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to compare concordance between ganglion cell-inner plexiform layer (GCIPL) data from the Cirrus optical coherence tomographer (OCT) Ganglion Cell Analysis (GCA) and visual fields (VFs), with and without Drasdo displacement. Methods From 296 open-angle glaucoma participants, GCIPL deviation and raw thickness data were extracted over locations per the 10-2 VF test grid, with and without application of Drasdo displacement, with global and eccentricity-dependent sensitivities and specificities calculated for both. With OCT and VF data classified as within or outside normative limits, pattern deviation values were compared using paired t-tests and Spearman correlations. Regression models were applied to pattern deviation values as a function of GCIPL thickness, and differences in model performance with and without displacement were compared using extra sums-of-squares F tests. Results There were small but significant improvements in global specificity without displacement (0.58-0.59 with displacement and 0.61 without displacement), without notable differences in sensitivity (0.77-0.78 with displacement and 0.76-0.78 without displacement). At abnormal VF locations and without displacement, a higher proportion of correct OCT classifications (P = 0.0008) and significant correlation with worsening pattern deviation values were observed (r = 0.50, P = 0.002). Regression models indicated significantly steeper slopes with Drasdo displacement centrally (P = 0.002-0.04). Conclusions With GCA deviation maps, small improvements in structure-function concordance were observed without displacement, which are unlikely to be clinically meaningful. Using GCIPL thickness data, significantly better structure-function concordance was observed centrally with Drasdo displacement. Translational Relevance Applying Drasdo displacement on probability-based reports is unlikely to alter clinical impressions of structure-function concordance, but applying displacement with GCIPL thickness data may improve detection of structure-function concordance.
Collapse
Affiliation(s)
- Janelle Tong
- Centre for Eye Health, University of New South Wales (UNSW), Sydney, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales (UNSW), Sydney, New South Wales, Australia
| | - Jack Phu
- Centre for Eye Health, University of New South Wales (UNSW), Sydney, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales (UNSW), Sydney, New South Wales, Australia
| | - David Alonso-Caneiro
- Queensland University of Technology, Contact Lens and Visual Optics Laboratory, Centre for Vision and Eye Research, School of Optometry and Vision Science, Queensland, Australia
| | - Sieu K Khuu
- School of Optometry and Vision Science, University of New South Wales (UNSW), Sydney, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, University of New South Wales (UNSW), Sydney, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales (UNSW), Sydney, New South Wales, Australia
| |
Collapse
|
6
|
Phu J, Tong J, Kalloniatis M. Intra-session repeatability of anterior chamber depth across the chamber width using Pentacam Scheimpflug imaging in healthy subjects. Ophthalmic Physiol Opt 2021; 41:1273-1284. [PMID: 34490921 DOI: 10.1111/opo.12880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 07/25/2021] [Accepted: 07/26/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE Despite the importance of anterior chamber depth (ACD) measurements in disease and ageing, the repeatability and their threshold for change is not known. Our purpose was to determine the intra-session repeatability of Pentacam Scheimpflug photography for measuring the ACD across the chamber width in healthy subjects and thus inform expected limits of normality. METHODS Pentacam Scheimpflug photography was used to obtain ACD measurements at 57 points across the central 8mm of the chamber width from one randomly selected eye of 130 healthy (normal vision and no ocular diseases, except age-normal cataracts) subjects (median age 58.0 years, interquartile range 46.3-63.0 years; 48 males, 82 females). Intra-session ACD measurements were compared. Univariate and multivariate linear regression was performed to identify categorical and continuous variables demonstrating a significant relationship with ACD and its repeatability. RESULTS Bland-Altman analyses showed no directional or depth-dependent bias in the difference between the first and second tests (mean bias -0.003 mm, 95% limits of agreement -0.115 to +0.109 mm). Multivariate analysis found gender to be a significant factor (p < 0.0001), but not age (p = 0.69) nor ethnicity (p = 0.65), although the model fit was poor (R2 = 0.004). There were no regional differences in repeatability measures found in males, but six locations in the superior aspect in females were found to be significantly different in their repeatability characteristics. Tolerance limits used to calculate the number of step sizes between <20 and >60-year-old age groups found 8.1-11.5 steps for females, and 7.5-9.2 steps for males. CONCLUSIONS Scheimpflug imaging using the Pentacam has excellent intra-session repeatability. Only gender appeared to affect repeatability characteristics, manifesting with a greater number of meaningful steps of change between two extremes of age range in females compared to males, which provides guidance for identifying clinically significant and measurable change between tests.
Collapse
Affiliation(s)
- Jack Phu
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| | - Janelle Tong
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| |
Collapse
|
7
|
Phu J, Wong B, Lim T, Kalloniatis M. Assessment of angle closure spectrum disease as a continuum of change using gonioscopy and anterior segment optical coherence tomography. Ophthalmic Physiol Opt 2020; 40:617-631. [PMID: 32794186 DOI: 10.1111/opo.12721] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Accepted: 06/25/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE Studies examining the anterior chamber angle and angle closure disease often compare quantitative angle information obtained using anterior segment optical coherence tomography (ASOCT) with one of several ordinal scales derived using gonioscopy. We test the assumption that the ordinal gonioscopic angle grades have equal step sizes and can be analysed using metric statistics. METHODS The medical records of 214 consecutive patients who were referred for assessment of the anterior chamber angle were prospectively examined using gonioscopy and ASOCT (Spectralis Optical Coherence Tomography, OCT, www.heidelbergengineering.com). Anterior chamber angle parameters (angle opening distance, AOD, and trabecular-iris space area, TISA at 500 and 750 microns) were extracted from ASOCT images using a semi-automated segmentation algorithm written on MATLAB (www.mathworks.com). We first matched the quantitative values for each gonioscopic grade (0-4, from no structures visible to ciliary body visible) and described the frequency distributions to determine separability. We then applied a grade-agnostic clustering algorithm to determine the concordance between algorithm-clustered groups (using solely quantitative data) and those obtained using gonioscopy. RESULTS The frequency distributions of the quantitative ASOCT parameters for each angle grade were mostly non-parametric and displayed unique distribution characteristics, with a floor effect seen for grade 0 and the lack of a ceiling effect seen for grades 3 and 4. Although we found significant differences in quantitative values across the five angle grades using the frequency distributions, some pairwise comparisons were indistinguishable (such as grades 0 and 1, and grades 3 and 4) due to the overlaps in distributions. On average, differences in quantitative values were consistent between gonioscopic grade steps, but there remained substantial variability that confounds prediction of change between ordinal steps. The clustering algorithm showed approximately 10% of cases with the same group assignment as that of the gonioscopic grade, improving slightly to 30% when the top 5% of quantitative data were excluded from analysis. CONCLUSIONS Our results do not necessarily support the assumption that the ordinal scales used in gonioscopy can be interpreted using an interval scale. We highlight the need for better methods of describing the course and risk of angle closure spectrum disease to identify disease progression and conversion, where gonioscopy remains the gold standard.
Collapse
Affiliation(s)
- Jack Phu
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| | - Brian Wong
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| | - Thalia Lim
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| |
Collapse
|
8
|
Phu J, Tong J, Zangerl B, Le JL, Kalloniatis M. Cluster analysis reveals patterns of age-related change in anterior chamber depth for gender and ethnicity: clinical implications. Ophthalmic Physiol Opt 2020; 40:632-649. [PMID: 32644209 PMCID: PMC7540376 DOI: 10.1111/opo.12714] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 05/28/2020] [Indexed: 12/16/2022]
Abstract
Purpose To identify patterns of age‐, gender‐ and refractive‐ related changes in Scheimpflug‐based anterior chamber depth across the central 8 mm of chamber width, to derive normative models, potentially useful for angle closure disease diagnosis. Methods This was a retrospective, cross‐sectional study. Scheimpflug photography was used to obtain anterior chamber depth measurements at 57 points across the central 8 mm of the chamber width from one eye of each healthy subject (male Caucasians (n = 189), female Caucasians (n = 186), male Asians (n = 165) and female Asians (n = 181)). Sliding window and nonlinear regression analysis was used to identify the age‐related changes in chamber depth. Hierarchical cluster analysis was used to identify test locations with statistically identical age‐related shifts, which were used to perform age‐correction for all subjects, resulting in normative distributions of chamber depth across the chamber width. The model was examined with and without the contribution of spherical equivalent refractive error. Results Distinct clusters, demonstrating statistically indistinguishable age‐related changes of chamber depth over time, were identified. These age‐related changes followed a nonlinear regression (fifth or sixth order polynomial). Females tended to have a greater rate of chamber depth shallowing. Incorporating refractive error into the model produced minimal changes to the fit relative to the ground truth. Comparisons with cut‐offs for angle closure from the literature showed that ageing alone was insufficient for identifying angle closure disease. Conclusions Age‐, ethnicity‐ and gender‐related differences need to be acknowledged in order to utilise anterior chamber depth data for angle closure disease diagnosis correctly. Ageing alone does not adequately account for the angle closure disease process.
Collapse
Affiliation(s)
- Jack Phu
- Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia
| | - Janelle Tong
- Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia
| | - Barbara Zangerl
- Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia
| | - Janet Ly Le
- Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia
| |
Collapse
|
9
|
Visualizing the Consistency of Clinical Characteristics that Distinguish Healthy Persons, Glaucoma Suspect Patients, and Manifest Glaucoma Patients. ACTA ACUST UNITED AC 2020; 3:274-287. [DOI: 10.1016/j.ogla.2020.04.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 03/27/2020] [Accepted: 04/01/2020] [Indexed: 11/18/2022]
|