Şahin S, Ünlü C, Trabzon L. Affinity biosensors developed with quantum dots in microfluidic systems. EMERGENT MATERIALS 2021; 4:187-209. [PMID: 33718778 PMCID: PMC7944724 DOI: 10.1007/s42247-021-00195-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 02/18/2021] [Indexed: 04/14/2023]
Abstract
Quantum dots (QDs) are synthetic semiconductor nanocrystals with unique optical and electronic properties due to their size (2-10 nm) such as high molar absorption coefficient (10-100 times higher than organic dyes), resistance to chemical degradation, and unique optoelectronic properties due to quantum confinement (high quantum yield, emission color change with size). Compared to organic fluorophores, the narrower emission band and wider absorption bands of QDs offer great advantages in cell imaging and biosensor applications. The optoelectronic features of QDs have prompted their intensive use in bioanalytical, biophysical, and biomedical research. As the nanomaterials have been integrated into microfluidic systems, microfluidic technology has accelerated the adaptation of nanomaterials to clinical evaluation together with the advantages such as being more economical, more reproducible, and more susceptible to modification and integration with other technologies. Microfluidic systems serve an important role by being a platform in which QDs are integrated for biosensing applications. As we combine the advantages of QDs and microfluidic technology for biosensing technology, QD-based biosensor integrated with microfluidic systems can be used as an advanced and versatile diagnostic technology in case of pandemic. Specifically, there is an urgent necessity to have reliable and fast detection systems for COVID-19 virus. In this review, affinity-based biosensing mechanisms which are developed with QDs are examined in the domain of microfluidic approach. The combination of microfluidic technology and QD-based affinity biosensors are presented with examples in order to develop a better technological framework of diagnostic for COVID-19 virus.
Collapse
Affiliation(s)
- Sultan Şahin
- Nanosicence and Nanoengineering Department, Istanbul Technical University, Istanbul, Turkey
- Nanotechnology Research and Application Center – ITUnano, Istanbul Technical University, Istanbul, Turkey
- MEMS Research Center, Istanbul Technical University, Istanbul, Turkey
| | - Caner Ünlü
- Nanosicence and Nanoengineering Department, Istanbul Technical University, Istanbul, Turkey
- Nanotechnology Research and Application Center – ITUnano, Istanbul Technical University, Istanbul, Turkey
- Department of Chemistry, Istanbul Technical University, Istanbul, Turkey
| | - Levent Trabzon
- Nanosicence and Nanoengineering Department, Istanbul Technical University, Istanbul, Turkey
- Nanotechnology Research and Application Center – ITUnano, Istanbul Technical University, Istanbul, Turkey
- MEMS Research Center, Istanbul Technical University, Istanbul, Turkey
- Faculty of Mechanical Engineering, Istanbul Technical University, Istanbul, Turkey
| |
Collapse
|
2
|
Zhong N, Chen M, Wang Z, Xin X, Li B. Photochemical device for selective detection of phenol in aqueous solutions. LAB ON A CHIP 2018; 18:1621-1632. [PMID: 29766202 DOI: 10.1039/c8lc00317c] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
We demonstrate that a lab-on-a-chip device (hereafter termed a photochemical phenol sensor) that integrates a photocatalytic long-period fiber grating (PLPFG), fiber Bragg grating (FBG), polymer membrane, ultraviolet (UV) visible light, and microchannels can be exploited to selectively detect phenol in aqueous solutions. The novel PLPFG consisted of a thinned long-period fiber grating (LPFG) and a UV-visible-light-driven Er3+:YAlO3/SiO2/TiO2 (EYST) coating. The polymer membrane with high phenol permselectivity was synthesized using PEBA2533 doped with β-cyclodextrin and was wrapped around the EYST surface, thus forming a microchannel between the membrane and PLPFG to enable the injection and outflow of standard analytes. Subsequently, a Z-shaped microchannel in a PMMA plate was fabricated and employed as a storage chamber for phenol analytes. To realize the EYST photocatalyst, UV-visible-light was irradiated using a tapered UV optical array. Thereafter, to eliminate the effect of temperature on the device, a FBG sensor as a temperature-compensating element was presented. To demonstrate the sensitivity and selectivity of the proposed device, we investigated the effects of the EYST coating's thickness, phenol-based analytes and temperature on the sensitivity and accuracy of the device for measuring phenol concentrations. The results of our present study suggest that the photochemical sensor is effective over a wide range of concentrations (7.5 μg L-1 to 100 mg L-1), pH values (2.0 to 14.0), and temperatures (10 to 48 °C) for selective detection of phenol in aqueous solutions. Thus, the proposed lab-on-a-chip device may be useful for accurate determination of phenol concentrations in real samples.
Collapse
Affiliation(s)
- Nianbing Zhong
- Chongqing Key Laboratory of Modern Photoelectric Detection Technology and Instrument, Chongqing Key Laboratory of Fiber Optic Sensor and Photodetector, Chongqing Energy Internet Engineering Center, Chongqing University of Technology, Chongqing 400054, China.
| | | | | | | | | |
Collapse
|
3
|
Benito-Peña E, Valdés MG, Glahn-Martínez B, Moreno-Bondi MC. Fluorescence based fiber optic and planar waveguide biosensors. A review. Anal Chim Acta 2016; 943:17-40. [PMID: 27769374 PMCID: PMC7094704 DOI: 10.1016/j.aca.2016.08.049] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Revised: 08/25/2016] [Accepted: 08/29/2016] [Indexed: 12/21/2022]
Abstract
The application of optical biosensors, specifically those that use optical fibers and planar waveguides, has escalated throughout the years in many fields, including environmental analysis, food safety and clinical diagnosis. Fluorescence is, without doubt, the most popular transducer signal used in these devices because of its higher selectivity and sensitivity, but most of all due to its wide versatility. This paper focuses on the working principles and configurations of fluorescence-based fiber optic and planar waveguide biosensors and will review biological recognition elements, sensing schemes, as well as some major and recent applications, published in the last ten years. The main goal is to provide the reader a general overview of a field that requires the joint collaboration of researchers of many different areas, including chemistry, physics, biology, engineering, and material science.
Collapse
Affiliation(s)
- Elena Benito-Peña
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid, Spain
| | - Mayra Granda Valdés
- Department of Analytical Chemistry, Faculty of Chemistry, University of La Habana, 10400 La Habana, Cuba
| | - Bettina Glahn-Martínez
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid, Spain
| | - Maria C Moreno-Bondi
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid, Spain.
| |
Collapse
|
4
|
Ankireddy SR, Kim J. Dopamine-functionalized InP/ZnS quantum dots as fluorescence probes for the detection of adenosine in microfluidic chip. Int J Nanomedicine 2015; 10 Spec Iss:121-8. [PMID: 26347351 PMCID: PMC4554435 DOI: 10.2147/ijn.s88465] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Microbeads are frequently used as solid supports for biomolecules such as proteins and nucleic acids in heterogeneous microfluidic assays. Chip-based, quantum dot (QD)-bead-biomolecule probes have been used for the detection of various types of DNA. In this study, we developed dopamine (DA)-functionalized InP/ZnS QDs (QDs-DA) as fluorescence probes for the detection of adenosine in microfluidic chips. The photoluminescence (PL) intensity of the QDs-DA is quenched by Zn(2+) because of the strong coordination interactions. In the presence of adenosine, Zn(2+) cations preferentially bind to adenosine, and the PL intensity of the QDs-DA is recovered. A polydimethylsiloxane-based microfluidic chip was fabricated, and adenosine detection was confirmed using QDs-DA probes.
Collapse
Affiliation(s)
- Seshadri Reddy Ankireddy
- Department of chemical and Biological Engineering, Gachon University, Seongnam, Gyeonggi-Do, South Korea
| | - Jongsung Kim
- Department of chemical and Biological Engineering, Gachon University, Seongnam, Gyeonggi-Do, South Korea
| |
Collapse
|
5
|
Di Mauro AE, Toscanini M, Piovani D, Samperi F, Curri ML, Corricelli M, De Caro L, Siliqi D, Comparelli R, Agostiano A, Destri S, Striccoli M. Segmented poly(styrene-co-vinylpyridine) as multivalent host for CdSe nanocrystal based nanocomposites. Eur Polym J 2014. [DOI: 10.1016/j.eurpolymj.2014.09.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
6
|
Zhang H, Hu X, Fu X. Aptamer-based microfluidic beads array sensor for simultaneous detection of multiple analytes employing multienzyme-linked nanoparticle amplification and quantum dots labels. Biosens Bioelectron 2014; 57:22-9. [PMID: 24534576 DOI: 10.1016/j.bios.2014.01.054] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2013] [Revised: 01/18/2014] [Accepted: 01/28/2014] [Indexed: 02/01/2023]
Abstract
This study reports the development of an aptamer-mediated microfluidic beads-based sensor for multiple analytes detection and quantification using multienzyme-linked nanoparticle amplification and quantum dots labels. Adenosine and cocaine were selected as the model analytes to validate the assay design based on strand displacement induced by target-aptamer complex. Microbeads functionalized with the aptamers and modified electron rich proteins were arrayed within a microfluidic channel and were connected with the horseradish peroxidases (HRP) and capture DNA probe derivative gold nanoparticles (AuNPs) via hybridization. The conformational transition of aptamer induced by target-aptamer complex contributes to the displacement of functionalized AuNPs and decreases the fluorescence signal of microbeads. In this approach, increased binding events of HRP on each nanosphere and enhanced mass transport capability inherent from microfluidics are integrated for enhancing the detection sensitivity of analytes. Based on the dual signal amplification strategy, the developed aptamer-based microfluidic bead array sensor could discriminate as low as 0.1 pM of adenosine and 0.5 pM cocaine, and showed a 500-fold increase in detection limit of adenosine compared to the off-chip test. The results proved the microfluidic-based method was a rapid and efficient system for aptamer-based targets assays (adenosine (0.1 pM) and cocaine (0.5 pM)), requiring only minimal (microliter) reagent use. This work demonstrated the successful application of aptamer-based microfluidic beads array sensor for detection of important molecules in biomedical fields.
Collapse
Affiliation(s)
- He Zhang
- School of Chemistry and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, People׳s Republic of China.
| | - Xinjiang Hu
- School of Chemistry and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, People׳s Republic of China
| | - Xin Fu
- School of Chemistry and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, People׳s Republic of China
| |
Collapse
|
7
|
Sugawara M, Shoji A, Sakamoto M. Pore-forming compounds as signal transduction elements for highly sensitive biosensing. ANAL SCI 2014; 30:119-28. [PMID: 24420253 DOI: 10.2116/analsci.30.119] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Pore-forming compounds are attracting much attention due to the signal transduction ability for the development of highly sensitive biosensing. In this review, we describe an overview of the recent advances made by our group in the design of molecular sensing interfaces of spherical and planar lipid bilayers and natural bilayers. The potential uses of pore-forming compounds, such as gramicidin and MCM-41, in lipid bilayers and natural glutamate receptor channels in biomembrane are presented.
Collapse
Affiliation(s)
- Masao Sugawara
- Department of Chemistry, College of Humanities and Sciences, Nihon University
| | | | | |
Collapse
|
8
|
Jin P, Jiao C, Guo Z, He Y, Zhu S, Tian H, Zhu W. Rational design of a turn-on fluorescent sensor for α-ketoglutaric acid in a microfluidic chip. Chem Sci 2014. [DOI: 10.1039/c4sc01378f] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A rational design of turn-on fluorescent chemosensors for monitoring α-ketoglutaric acid has been developed with a microfluidic chip, indicative of a potential platform for high-throughput screening and monitoring of kinetics, especially in biological fields.
Collapse
Affiliation(s)
- Pengwei Jin
- Shanghai Key Laboratory of Functional Materials Chemistry
- Key Laboratory for Advanced Materials and Institute of Fine Chemicals
- East China University of Science and Technology
- Shanghai 200237, P. R. China
| | - Changhong Jiao
- Shanghai Key Laboratory of Functional Materials Chemistry
- Key Laboratory for Advanced Materials and Institute of Fine Chemicals
- East China University of Science and Technology
- Shanghai 200237, P. R. China
| | - Zhiqian Guo
- Shanghai Key Laboratory of Functional Materials Chemistry
- Key Laboratory for Advanced Materials and Institute of Fine Chemicals
- East China University of Science and Technology
- Shanghai 200237, P. R. China
| | - Ye He
- Shanghai Key Laboratory of Functional Materials Chemistry
- Key Laboratory for Advanced Materials and Institute of Fine Chemicals
- East China University of Science and Technology
- Shanghai 200237, P. R. China
| | - Shiqin Zhu
- Shanghai Key Laboratory of Functional Materials Chemistry
- Key Laboratory for Advanced Materials and Institute of Fine Chemicals
- East China University of Science and Technology
- Shanghai 200237, P. R. China
| | - He Tian
- Shanghai Key Laboratory of Functional Materials Chemistry
- Key Laboratory for Advanced Materials and Institute of Fine Chemicals
- East China University of Science and Technology
- Shanghai 200237, P. R. China
| | - Weihong Zhu
- Shanghai Key Laboratory of Functional Materials Chemistry
- Key Laboratory for Advanced Materials and Institute of Fine Chemicals
- East China University of Science and Technology
- Shanghai 200237, P. R. China
| |
Collapse
|
9
|
Ai X, Ma Q, Su X. Multiplex DNA sensor for BRAF and BRCA detection. Anal Biochem 2013; 438:22-8. [DOI: 10.1016/j.ab.2013.02.029] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2012] [Revised: 02/27/2013] [Accepted: 02/28/2013] [Indexed: 11/29/2022]
|
10
|
Microfluidic bead-based multienzyme-nanoparticle amplification for detection of circulating tumor cells in the blood using quantum dots labels. Anal Chim Acta 2013; 779:64-71. [DOI: 10.1016/j.aca.2013.03.060] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2013] [Revised: 03/21/2013] [Accepted: 03/25/2013] [Indexed: 11/17/2022]
|
11
|
Single-pipetting microfluidic assay device for rapid detection of Salmonella from poultry package. Biosens Bioelectron 2013; 40:342-9. [DOI: 10.1016/j.bios.2012.07.076] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Revised: 07/03/2012] [Accepted: 07/13/2012] [Indexed: 11/15/2022]
|
12
|
Hanada S, Fujioka K, Futamura Y, Manabe N, Hoshino A, Yamamoto K. Evaluation of anti-inflammatory drug-conjugated silicon quantum dots: their cytotoxicity and biological effect. Int J Mol Sci 2013; 14:1323-34. [PMID: 23306154 PMCID: PMC3565323 DOI: 10.3390/ijms14011323] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 01/01/2013] [Accepted: 01/05/2013] [Indexed: 11/16/2022] Open
Abstract
Silicon quantum dots (Si-QDs) have great potential for biomedical applications, including their use as biological fluorescent markers and carriers for drug delivery systems. Biologically inert Si-QDs are less toxic than conventional cadmium-based QDs, and can modify the surface of the Si-QD with covalent bond. We synthesized water-soluble alminoprofen-conjugated Si-QDs (Ap-Si). Alminoprofen is a non-steroid anti-inflammatory drug (NSAID) used as an analgesic for rheumatism. Our results showed that the "silicon drug" is less toxic than the control Si-QD and the original drug. These phenomena indicate that the condensed surface integration of ligand/receptor-type drugs might reduce the adverse interaction between the cells and drug molecules. In addition, the medicinal effect of the Si-QDs (i.e., the inhibition of COX-2 enzyme) was maintained compared to that of the original drug. The same drug effect is related to the integration ratio of original drugs, which might control the binding interaction between COX-2 and the silicon drug. We conclude that drug conjugation with biocompatible Si-QDs is a potential method for functional pharmaceutical drug development.
Collapse
Affiliation(s)
- Sanshiro Hanada
- Vice Director-General’s Lab, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655, Japan; E-Mails: (Y.F.); (N.M.); (A.H.); (K.Y.)
| | - Kouki Fujioka
- Department of Molecular Cell Biology, Institute of DNA Medicine, Jikei University School of Medicine, Tokyo 105-8461, Japan; E-Mail:
| | - Yasuhiro Futamura
- Vice Director-General’s Lab, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655, Japan; E-Mails: (Y.F.); (N.M.); (A.H.); (K.Y.)
| | - Noriyoshi Manabe
- Vice Director-General’s Lab, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655, Japan; E-Mails: (Y.F.); (N.M.); (A.H.); (K.Y.)
| | - Akiyoshi Hoshino
- Vice Director-General’s Lab, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655, Japan; E-Mails: (Y.F.); (N.M.); (A.H.); (K.Y.)
| | - Kenji Yamamoto
- Vice Director-General’s Lab, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655, Japan; E-Mails: (Y.F.); (N.M.); (A.H.); (K.Y.)
| |
Collapse
|
13
|
Abstract
Laminated object manufacturing (LOM) technology using polymer sheets is an easy and affordable method for rapid prototyping of Lab-on-a-Chip (LOC) systems. It has recently been used to fabricate a miniature 96 sample ELISA lab-on-a-chip (ELISA-LOC) by integrating the washing step directly into an ELISA plate. LOM has been shown to be capable of creating complex 3D microfluidics through the assembly of a stack of polymer sheets with features generated by laser micromachining and by bonding the sheets together with adhesive. A six layer ELISA-LOC was fabricated with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser with simple microfluidic features including a miniature 96-well sample plate. Immunological assays can be carried out in several configurations (1 × 96 wells, 2 × 48 wells, or 4 × 24 wells). The system includes three main functional elements: (1) a reagent loading fluidics module, (2) an assay and detection wells plate, and (3) a reagent removal fluidics module. The ELISA-LOC system combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected Staphylococcal enterotoxin B (SEB) at concentrations as low as 0.1 ng/ml, a detection level similar to that reported for conventional ELISA. ELISA-LOC can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without the laboratory required for conventional ELISA, and therefore may be more useful for global healthcare delivery.
Collapse
Affiliation(s)
- Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA Center for Devices and Radiological Health (CDRH), Silver Spring, MD, USA.
| | | | | |
Collapse
|
14
|
Zhang H, Liu L, Fu X, Zhu Z. Microfluidic beads-based immunosensor for sensitive detection of cancer biomarker proteins using multienzyme-nanoparticle amplification and quantum dots labels. Biosens Bioelectron 2012. [PMID: 23202325 DOI: 10.1016/j.bios.2012.10.076] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
This study reports the development of a microfluidic beads-based immunosensor for sensitive detection of cancer biomarker α-fetoprotein (AFP) that uses multienzyme-nanoparticle amplification and quantum dots labels. This method utilizes microbeads functionalized with the capture antibodies (Ab₁) and modified electron rich proteins as sensing platform that was fabricated within a microfluidic channel, and uses gold nanoparticles (AuNPs) functionalized with the horseradish peroxidase (HRP) and the detection antibodies (Ab₂) as label. Greatly enhanced sensitivity for the cancer biomarker is based on a dual signal amplification strategy: first, the large surface area of Au nanoparticle carrier allows several binding events of HRP on each nanosphere. Enhanced sensitivity was achieved by introducing the multi-HRP-antibody functionalized AuNPs onto the surface of microbeads through "sandwich" immunoreactions and subsequently multiple biotin moieties could be deposited onto the surface of beads resulted from the oxidation of biotin-tyramine by hydrogen peroxide. Streptavidin-labeled quantum dots were then allowed to bind to the deposited biotin moieties and displayed the signal. Secondly, enhanced mass transport capability inherent from microfluidics leads to higher capture efficiency of targets because continuous flow within micro-channel delivers fresh analyte solution to the reaction site which maintains a high concentration gradient differential to enhance mass transport. Based on the dual signal amplification strategy, the developed microfluidic bead-based immunosensor could discriminate as low as 0.2 pg mL⁻¹ AFP in 10 μL of undiluted calf serum (0.2 fg/chip), and showed a 500-fold increase in detection limit compared to the off-chip test and 50-fold increase in detection limit compared to microfluidic beads-based immunoassay using single label HRP-Ab₂. The immunosensor showed acceptable repeatability and reproducibility. This microfluidic beads-based immunosensor is a promising platform for disease-related biomolecules at the lowest level at their earliest incidence.
Collapse
Affiliation(s)
- He Zhang
- School of Chemistry and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, People's Republic of China.
| | | | | | | |
Collapse
|
15
|
Yoon JY, Kim B. Lab-on-a-chip pathogen sensors for food safety. SENSORS (BASEL, SWITZERLAND) 2012; 12:10713-41. [PMID: 23112625 PMCID: PMC3472853 DOI: 10.3390/s120810713] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2012] [Revised: 06/28/2012] [Accepted: 07/04/2012] [Indexed: 02/08/2023]
Abstract
There have been a number of cases of foodborne illness among humans that are caused by pathogens such as Escherichia coli O157:H7, Salmonella typhimurium, etc. The current practices to detect such pathogenic agents are cell culturing, immunoassays, or polymerase chain reactions (PCRs). These methods are essentially laboratory-based methods that are not at all real-time and thus unavailable for early-monitoring of such pathogens. They are also very difficult to implement in the field. Lab-on-a-chip biosensors, however, have a strong potential to be used in the field since they can be miniaturized and automated; they are also potentially fast and very sensitive. These lab-on-a-chip biosensors can detect pathogens in farms, packaging/processing facilities, delivery/distribution systems, and at the consumer level. There are still several issues to be resolved before applying these lab-on-a-chip sensors to field applications, including the pre-treatment of a sample, proper storage of reagents, full integration into a battery-powered system, and demonstration of very high sensitivity, which are addressed in this review article. Several different types of lab-on-a-chip biosensors, including immunoassay- and PCR-based, have been developed and tested for detecting foodborne pathogens. Their assay performance, including detection limit and assay time, are also summarized. Finally, the use of optical fibers or optical waveguide is discussed as a means to improve the portability and sensitivity of lab-on-a-chip pathogen sensors.
Collapse
Affiliation(s)
- Jeong-Yeol Yoon
- Department of Agricultural and Biosystems Engineering, the University of Arizona, Tucson, AZ 85721, USA.
| | | |
Collapse
|
16
|
Quantum dot based rapid tests for zearalenone detection. Anal Bioanal Chem 2012; 403:3013-24. [DOI: 10.1007/s00216-012-5981-z] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2011] [Revised: 03/20/2012] [Accepted: 03/26/2012] [Indexed: 12/31/2022]
|
17
|
Ghafari H, Hanley QS. Analysis of layered assays and volume microarrays in stratified media. Analyst 2012; 137:5520-6. [DOI: 10.1039/c2an35767d] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
18
|
Tavares AJ, Noor MO, Vannoy CH, Algar WR, Krull UJ. On-Chip Transduction of Nucleic Acid Hybridization Using Spatial Profiles of Immobilized Quantum Dots and Fluorescence Resonance Energy Transfer. Anal Chem 2011; 84:312-9. [DOI: 10.1021/ac2025943] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Anthony J. Tavares
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359
Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
| | - M. Omair Noor
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359
Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
| | - Charles H. Vannoy
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359
Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
| | - W. Russ Algar
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359
Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
| | - Ulrich J. Krull
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359
Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
| |
Collapse
|
19
|
Multienzyme-nanoparticles amplification for sensitive virus genotyping in microfluidic microbeads array using Au nanoparticle probes and quantum dots as labels. Biosens Bioelectron 2011; 29:89-96. [DOI: 10.1016/j.bios.2011.07.074] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2011] [Accepted: 07/28/2011] [Indexed: 01/27/2023]
|
20
|
|
21
|
Vannoy CH, Tavares AJ, Noor MO, Uddayasankar U, Krull UJ. Biosensing with quantum dots: a microfluidic approach. SENSORS (BASEL, SWITZERLAND) 2011; 11:9732-63. [PMID: 22163723 PMCID: PMC3231262 DOI: 10.3390/s111009732] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2011] [Revised: 10/04/2011] [Accepted: 10/17/2011] [Indexed: 01/09/2023]
Abstract
Semiconductor quantum dots (QDs) have served as the basis for signal development in a variety of biosensing technologies and in applications using bioprobes. The use of QDs as physical platforms to develop biosensors and bioprobes has attracted considerable interest. This is largely due to the unique optical properties of QDs that make them excellent choices as donors in fluorescence resonance energy transfer (FRET) and well suited for optical multiplexing. The large majority of QD-based bioprobe and biosensing technologies that have been described operate in bulk solution environments, where selective binding events at the surface of QDs are often associated with relatively long periods to reach a steady-state signal. An alternative approach to the design of biosensor architectures may be provided by a microfluidic system (MFS). A MFS is able to integrate chemical and biological processes into a single platform and allows for manipulation of flow conditions to achieve, by sample transport and mixing, reaction rates that are not entirely diffusion controlled. Integrating assays in a MFS provides numerous additional advantages, which include the use of very small amounts of reagents and samples, possible sample processing before detection, ultra-high sensitivity, high throughput, short analysis time, and in situ monitoring. Herein, a comprehensive review is provided that addresses the key concepts and applications of QD-based microfluidic biosensors with an added emphasis on how this combination of technologies provides for innovations in bioassay designs. Examples from the literature are used to highlight the many advantages of biosensing in a MFS and illustrate the versatility that such a platform offers in the design strategy.
Collapse
Affiliation(s)
- Charles H. Vannoy
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Rd. North, Mississauga, Ontario L5L 1C6, Canada; E-Mails: (C.H.V.); (A.J.T.); (M.O.N.); (U.U.)
| | | | | | | | - Ulrich J. Krull
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Rd. North, Mississauga, Ontario L5L 1C6, Canada; E-Mails: (C.H.V.); (A.J.T.); (M.O.N.); (U.U.)
| |
Collapse
|
22
|
You DJ, Geshell KJ, Yoon JY. Direct and sensitive detection of foodborne pathogens within fresh produce samples using a field-deployable handheld device. Biosens Bioelectron 2011; 28:399-406. [PMID: 21840701 DOI: 10.1016/j.bios.2011.07.055] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2011] [Revised: 07/21/2011] [Accepted: 07/21/2011] [Indexed: 10/17/2022]
Abstract
Direct and sensitive detection of foodborne pathogens from fresh produce samples was accomplished using a handheld lab-on-a-chip device, requiring little to no sample processing and enrichment steps for a near-real-time detection and truly field-deployable device. The detection of Escherichia coli K12 and O157:H7 in iceberg lettuce was achieved utilizing optimized Mie light scatter parameters with a latex particle immunoagglutination assay. The system exhibited good sensitivity, with a limit of detection of 10 CFU mL(-1) and an assay time of <6 min. Minimal pretreatment with no detrimental effects on assay sensitivity and reproducibility was accomplished with a simple and cost-effective KimWipes filter and disposable syringe. Mie simulations were used to determine the optimal parameters (particle size d, wavelength λ, and scatter angle θ) for the assay that maximize light scatter intensity of agglutinated latex microparticles and minimize light scatter intensity of the tissue fragments of iceberg lettuce, which were experimentally validated. This introduces a powerful method for detecting foodborne pathogens in fresh produce and other potential sample matrices. The integration of a multi-channel microfluidic chip allowed for differential detection of the agglutinated particles in the presence of the antigen, revealing a true field-deployable detection system with decreased assay time and improved robustness over comparable benchtop systems. Additionally, two sample preparation methods were evaluated through simulated field studies based on overall sensitivity, protocol complexity, and assay time. Preparation of the plant tissue sample by grinding resulted in a two-fold improvement in scatter intensity over washing, accompanied with a significant increase in assay time: ∼5 min (grinding) versus ∼1 min (washing). Specificity studies demonstrated binding of E. coli O157:H7 EDL933 to only O157:H7 antibody conjugated particles, with no cross-reactivity to K12. This suggests the adaptability of the system for use with a wide variety of pathogens, and the potential to detect in a variety of biological matrices with little to no sample pretreatment.
Collapse
Affiliation(s)
- David J You
- Department of Agricultural and Biosystems Engineering, The University of Arizona, Tucson, AZ 85721-0038, USA
| | | | | |
Collapse
|
23
|
Yang M, Sun S, Kostov Y, Rasooly A. An automated point-of-care system for immunodetection of staphylococcal enterotoxin B. Anal Biochem 2011; 416:74-81. [PMID: 21640067 PMCID: PMC3148523 DOI: 10.1016/j.ab.2011.05.014] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2011] [Revised: 04/28/2011] [Accepted: 05/10/2011] [Indexed: 01/19/2023]
Abstract
An automated point-of-care (POC) immunodetection system for immunological detection of staphylococcal enterotoxin B (SEB) was designed, fabricated, and tested. The system combines several elements: (i) enzyme-linked immunosorbent assay-lab-on-a-chip (ELISA-LOC) with fluidics, (ii) a charge-coupled device (CCD) camera detector, (iii) pumps and valves for fluid delivery to the ELISA-LOC, (iv) a computer interface board, and (v) a computer for controlling the fluidics, logging, and data analysis of the CCD data. The ELISA-LOC integrates a simple microfluidic system into a miniature 96-well sample plate, allowing the user to carry out immunological assays without a laboratory. The analyte is measured in a sandwich ELISA assay format combined with a sensitive electrochemiluminescence (ECL) detection method. Using the POC system, SEB, a major foodborne toxin, was detected at concentrations as low as 0.1 ng/ml. This is similar to the reported sensitivity of conventional ELISA. The open platform with simple modular fluid delivery automation design described here is interchangeable between detection systems, and because of its versatility it can also be used to automate many other LOC systems, simplifying LOC development. This new POC system is useful for carrying out various immunological and other complex medical assays without a laboratory and can easily be adapted for high-throughput biological screening in remote and resource-poor areas.
Collapse
Affiliation(s)
- Minghui Yang
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Steven Sun
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993
| | - Yordan Kostov
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
| | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993
- National Cancer Institute, Bethesda, MD 20892
| |
Collapse
|
24
|
Jaworski J, Yokoyama K, Zueger C, Chung WJ, Lee SW, Majumdar A. Polydiacetylene incorporated with peptide receptors for the detection of trinitrotoluene explosives. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:3180-3187. [PMID: 21275406 DOI: 10.1021/la104476p] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Because of their unique optical and stimuli-response properties, polydiacetylene-based platforms have been explored as an alternative to complex mechanical and electrical sensing systems. We linked chromic responsive polydiacetylene (PDA) onto a peptide-based molecular recognition element for trinitrotoluene (TNT) molecules in order to provide a system capable of responding to the presence of a TNT target. We first identified the trimer peptide receptor that could induce chromic changes on a PDA backbone. We then investigated the multivalent interactions between TNT and our peptide-based receptor by nuclear magnetic resonance (NMR) spectroscopy. We further characterized various parameters that affected the conjugated PDA system and hence the chromic response, including the size of end-group motifs, the surface density of receptors, and the length of alkane side chains. Taking these necessary design parameters into account, we demonstrated a modular system capable of transducing small-molecule TNT binding into a detectable signal. Our conjugated PDA-based sensor coupled with molecular recognition elements has already proven useful recently in the development of another sensitive and selective electronic sensor, though we expect that our results will also be valuable in the design of colorimetric sensors for small-molecule detection.
Collapse
Affiliation(s)
- Justyn Jaworski
- Joint Graduate Group in Bioengineering, University of California, Berkeley, California 94720 and University of California, San Francisco, California 94143, United States
| | | | | | | | | | | |
Collapse
|
25
|
Abstract
A biosensor is a sensing device that incorporates a biological sensing element and a transducer to produce electrochemical, optical, mass, or other signals in proportion to quantitative information about the analytes in the given samples. The microfluidic chip is an attractive miniaturized platform with valuable advantages, e.g., low cost analysis requiring low reagent consumption, reduced sample volume, and shortened processing time. Combination of biosensors and microfluidic chips enhances analytical capability so as to widen the scope of possible applications. This review provides an overview of recent research activities in the field of biosensors integrated on microfluidic chips, focusing on the working principles, characteristics, and applicability of the biosensors. Theoretical background and applications in chemical, biological, and clinical analysis are summarized and discussed.
Collapse
|
26
|
de Lange V, Binkert A, Vörös J, Bally M. Microarrays made easy: biofunctionalized hydrogel channels for rapid protein microarray production. ACS APPLIED MATERIALS & INTERFACES 2011; 3:50-57. [PMID: 21141937 DOI: 10.1021/am100849f] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
We present a simple, inexpensive, and sensitive technique for producing multiple copies of a hydrogel-based protein microarray. An agarose block containing 25 biofunctionalized channels is sliced perpendicularly to produce many identical biochips. Each microarray consists of 500 μm spots, which contain protein-coated microparticles physically trapped in porous SeaPrep agarose. Proteins diffuse readily through SeaPrep agarose, while the larger microparticles are immobilized in the hydrogel matrix. Without major assay optimization, the limit of detection is 12 pM for a sandwich assay detecting human IgG. These highly flexible, multiplexed arrays can be produced rapidly without any special instrumentation and are compatible with standard fluorescence-based read-out.
Collapse
Affiliation(s)
- Victoria de Lange
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | | | | | | |
Collapse
|
27
|
Slomkowski S, Basinska T. Polymer Nano- and Microparticle Based Systems for Medical Diagnostics. ACTA ACUST UNITED AC 2010. [DOI: 10.1002/masy.200900084] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
28
|
Sun S, Yang M, Kostov Y, Rasooly A. ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection. LAB ON A CHIP 2010; 10:2093-100. [PMID: 20544092 DOI: 10.1039/c003994b] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
A miniature 96 sample ELISA-lab-on-a-chip (ELISA-LOC) was designed, fabricated, and tested for immunological detection of Staphylococcal Enterotoxin B (SEB). The chip integrates a simple microfluidics system into a miniature ninety-six sample plate, allowing the user to carry out an immunological assay without a laboratory. Assay reagents are delivered into the assay plate without the need for separate devices commonly used in immunoassays. The ELISA-LOC was constructed using Laminated Object Manufacturing (LOM) technology to assemble six layers with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser. The ELISA-LOC has three main functional elements: reagent loading fluidics, assay and detection wells, and reagent removal fluidics, a simple "surface tension" valve used to control the flow. To enhance assay sensitivity and to perform the assay without a lab, ELISA-LOC detection combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected SEB at concentrations as low as 0.1 ng ml(-1), which is similar to the reported sensitivity of conventional ELISA. The fluidics system can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without a laboratory.
Collapse
Affiliation(s)
- Steven Sun
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, USA
| | | | | | | |
Collapse
|
29
|
Immunoassays in microfluidic systems. Anal Bioanal Chem 2010; 397:991-1007. [PMID: 20422163 DOI: 10.1007/s00216-010-3678-8] [Citation(s) in RCA: 223] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2010] [Revised: 03/21/2010] [Accepted: 03/22/2010] [Indexed: 10/19/2022]
Abstract
Immunoassays have greatly benefited from miniaturization in microfluidic systems. This review, which summarizes developments in microfluidics-based immunoassays since 2000, includes four sections, focusing on the configurations of immunoassays that have been implemented in microfluidics, the main fluid handling modalities that have been used for microfluidic immunoassays, multiplexed immunoassays in microfluidic platforms, and the emergence of label-free detection techniques. The field of microfluidic immunoassays is continuously improving and has great promise for the future.
Collapse
|
30
|
Farre C, Lansalot M, Bazzi R, Roux S, Marquette CA, Catanante G, Blum LJ, Charvet N, Louis C, Chaix C. Automated oligonucleotide solid-phase synthesis on nanosized silica particles using nano-on-micro assembled particle supports. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2010; 26:4941-4950. [PMID: 20000593 DOI: 10.1021/la903572q] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
This article describes an original strategy to enable solid-phase oligodeoxyribonucleotide (ODN) synthesis on nanosized silica particles. It consists of the reversible immobilization of silica nanoparticles (NPs) on micrometric silica beads. The resulting assemblies, called nano-on-micro (NOM) systems, are well adapted to ODN synthesis in an automated instrument. First, NPs are derivatized with OH functions. For NOM assembly preparation, these functions react with the silanols of the microbeads under specific experimental conditions. Furthermore, OH groups allow ODN synthesis on the nanoparticles via phosphoramidite chemistry. The stability of the NOM assemblies during ODN solid-phase synthesis is confirmed by scanning and transmission electron microscopy (SEM and TEM, respectively), together with dynamic light scattering analyses. Then, the release of ODN-functionalized nanoparticles is performed under mild conditions (1% NH(4)OH in water, 1 h, 60 degrees C). Our technique provides silica nanoparticles well functionalized with oligonucleotides, as demonstrated by hybridization experiments conducted with the cDNA target.
Collapse
Affiliation(s)
- Carole Farre
- Université de Lyon, Univ. Lyon 1, UMR 5180, Laboratoire des Sciences Analytiques, Villeurbanne, 69622 Cedex, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
|
32
|
Nanotechnology diagnostics for infectious diseases prevalent in developing countries. Adv Drug Deliv Rev 2010; 62:438-48. [PMID: 19931580 DOI: 10.1016/j.addr.2009.11.015] [Citation(s) in RCA: 93] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2009] [Accepted: 09/14/2009] [Indexed: 11/22/2022]
Abstract
Infectious diseases are prevalent in the developing world and are one of the developing world's major sources of morbidity and mortality. While infectious diseases can initiate in a localized region, they can spread rapidly at any moment due to the ease of traveling from one part of the world to the next. This could lead to a global pandemic. One key to preventing this spread is the development of diagnostics that can quickly identify the infectious agent so that one can properly treat or in some severe cases, quarantine a patient. There have been major advances in diagnostic technologies but infectious disease diagnostics are still based on 50-year technologies that are limited by speed of analysis, need for skilled workers, poor detection threshold and inability to detect multiple strains of infectious agents. Here, we describe advances in nanotechnology and microtechnology diagnostics for infectious diseases. In these diagnostic schemes, the nanomaterials are used as labels or barcodes while microfluidic systems are used to automate the sample preparation and the assays. We describe the current state of the field and the challenges.
Collapse
|
33
|
Powell TB, Tran PL, Kim K, Yoon JY. Size-dependent self-assembly of submicron/nano beads-protein conjugates for construction of a protein nanoarray. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2009; 29:2459-2463. [PMID: 21461343 PMCID: PMC3065829 DOI: 10.1016/j.msec.2009.07.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
A protein nanoarray is created when submicro and nano beads, varying in their size and each conjugated with different proteins, self-assemble to specific locations depending on the diameter matching the surface electron beam patterns created. Protein binding is confirmed from the fluorescence attenuation of the beads upon antigen-antibody binding on the bead surface. This method, called size-dependent self-assembly, allows control of the location of each type of bead, and thus, control of the location of multiple proteins. It provides fast multi-component patterning with a high binding resolution, which can be detected using a fluorescent light microscope. This method is developed to be a simple stand-alone tool for analysis of protein interactions. In addition, it has the potential to be used in conjunction with other methods protein analysis methods, such as enzyme-linked immunosorbent assay (ELISA) and atomic force microscopy (AFM).
Collapse
Affiliation(s)
- Tremaine B. Powell
- Department of Agricultural and Biosystems Engineering, The University of Arizona, Tucson, AZ 85721-0038, USA
| | - Phat L. Tran
- Biomedical Engineering Graduate IDP, The University of Arizona, Tucson, AZ 85721-0038, USA
| | - Keesung Kim
- Department of Agricultural and Biosystems Engineering, The University of Arizona, Tucson, AZ 85721-0038, USA
| | - Jeong-Yeol Yoon
- Department of Agricultural and Biosystems Engineering, The University of Arizona, Tucson, AZ 85721-0038, USA
- Biomedical Engineering Graduate IDP, The University of Arizona, Tucson, AZ 85721-0038, USA
| |
Collapse
|
34
|
Lin DH, Taylor CR, French Anderson W, Scherer A, Kartalov EP. Internally calibrated quantification of VEGF in human plasma by fluorescence immunoassays in disposable elastomeric microfluidic devices. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 878:258-63. [PMID: 19748324 DOI: 10.1016/j.jchromb.2009.08.038] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2009] [Revised: 08/24/2009] [Accepted: 08/25/2009] [Indexed: 11/30/2022]
Abstract
Herein we report on a proof of principle for the reproducible quantification of Vascular Endothelial Growth Factor (VEGF) in human plasma by fluorescence sandwich immunoassays using disposable polydimethylsiloxane (PDMS) microfluidic chips. The system requires 100 times less sample than typical clinical blood tests, while its current quantification limit is established at 4pM. The in-built calibration method of spiking the plasma with known concentrations of commercially available antigen avoids common sources of error and improves the reliability of the test results. The demonstrated technique is important for immunoassay applications in fundamental scientific research and "point-of-care" (POC) biomedical diagnostics. In particular, the system is immediately applicable to microfluidic quantification of VEGF in human plasma in cancer studies.
Collapse
Affiliation(s)
- David H Lin
- Electrical Engineering Dept, California Institute of Technology, Pasadena, 91125, United States
| | | | | | | | | |
Collapse
|
35
|
Mairhofer J, Roppert K, Ertl P. Microfluidic systems for pathogen sensing: a review. SENSORS 2009; 9:4804-23. [PMID: 22408555 PMCID: PMC3291940 DOI: 10.3390/s90604804] [Citation(s) in RCA: 146] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2009] [Revised: 06/04/2009] [Accepted: 06/08/2009] [Indexed: 01/21/2023]
Abstract
Rapid pathogen sensing remains a pressing issue today since conventional identification methodsare tedious, cost intensive and time consuming, typically requiring from 48 to 72 h. In turn, chip based technologies, such as microarrays and microfluidic biochips, offer real alternatives capable of filling this technological gap. In particular microfluidic biochips make the development of fast, sensitive and portable diagnostic tools possible, thus promising rapid and accurate detection of a variety of pathogens. This paper will provide a broad overview of the novel achievements in the field of pathogen sensing by focusing on methods and devices that compliment microfluidics.
Collapse
Affiliation(s)
- Jürgen Mairhofer
- Department of Biotechnology, University of Natural Resources and Applied Life Sciences, Muthgasse 18, 1190 Vienna, Austria
| | - Kriemhilt Roppert
- Division of Nano-System-Technologies, Austrian Research Centers GmbH – ARC, Donau-City-Street 1, 1220 Vienna, Austria
| | - Peter Ertl
- Division of Nano-System-Technologies, Austrian Research Centers GmbH – ARC, Donau-City-Street 1, 1220 Vienna, Austria
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +43-(0)50550-4305; Fax: +43-(0)50550-4399
| |
Collapse
|
36
|
Tosi A, Mazzitelli S, Capretto L, Guerrieri R, Nastruzzi C. Optimization of lipospheres production by factorial design and their performances on a dielectrophoretic lab-on-a-chip platform. Colloids Surf A Physicochem Eng Asp 2009. [DOI: 10.1016/j.colsurfa.2009.03.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
37
|
Sin MLY, Shimabukuro Y, Wong PK. Hybrid electrokinetics for separation, mixing, and concentration of colloidal particles. NANOTECHNOLOGY 2009; 20:165701. [PMID: 19420574 DOI: 10.1088/0957-4484/20/16/165701] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
The advent of nanotechnology has facilitated the preparation of colloidal particles with adjustable sizes and the control of their size-dependent properties. Physical manipulation, such as separation, mixing, and concentration, of these colloidal particles represents an essential step for fully utilizing their potential in a wide spectrum of nanotechnology applications. In this study, we investigate hybrid electrokinetics, the combination of dielectrophoresis and electrohydrodynamics, for active manipulation of colloidal particles ranging from nanometers to micrometers in size. A concentric electrode configuration, which is optimized for generating electrohydrodynamic flow, has been designed to elucidate the effectiveness of hybrid electrokinetics and define the operating regimes for different microfluidic operations. The results indicate that the relative importance of electrohydrodynamics increases with decreasing particle size as predicted by a scaling analysis and that electrohydrodynamics is pivotal for manipulating nanoscale particles. Using the concentric electrodes, we demonstrate separation, mixing, and concentration of colloidal particles by adjusting the relative strengths of different electrokinetic phenomena. The effectiveness of hybrid electrokinetics indicates its potential to serve as a generic technique for active manipulation of colloidal particles in various nanotechnology applications.
Collapse
Affiliation(s)
- Mandy L Y Sin
- Department of Aerospace and Mechanical Engineering, University of Arizona, Tucson, AZ, USA
| | | | | |
Collapse
|
38
|
Liu C, Qiu X, Ongagna S, Chen D, Chen Z, Abrams WR, Malamud D, Corstjens PL, Bau HH. A timer-actuated immunoassay cassette for detecting molecular markers in oral fluids. LAB ON A CHIP 2009; 9:768-76. [PMID: 19255658 PMCID: PMC2706488 DOI: 10.1039/b814322f] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
An inexpensive, hand-held, point-of-care, disposable, self-contained immunoassay cassette comprised of air pouches for pumping, a metering chamber, reagents storage chambers, a mixer, and a lateral flow strip was designed, constructed, and tested. The assay was carried out in a consecutive flow format. The detection was facilitated with up-converting phosphor (UCP) reporter particles. The automated, timely pumping of the various reagents was driven by a spring-loaded timer. The utility of the cassette was demonstrated by detecting antibodies to HIV in saliva samples and further evaluated with a non-contagious, haptenized DNA assay. The cassette has several advantages over dip sticks such as sample preprocessing, integrated storage of reagents, and automated operation that reduces operator errors and training. The cassette and actuator described herein can readily be extended to detect biomarkers of other diseases in body fluids and other fluids at the point of care. The system is particularly suitable for resource-poor countries, where funds and trained personnel are in short supply.
Collapse
Affiliation(s)
- Changchun Liu
- Department of Mechanical Engineering and Applied Mechanics, Philadelphia, PA 19104-6315, USA
| | - Xianbo Qiu
- Department of Mechanical Engineering and Applied Mechanics, Philadelphia, PA 19104-6315, USA
| | - Serge Ongagna
- Department of Basic Sciences, New York University College of Dentistry, New York, 10010, USA
| | - Dafeng Chen
- Department of Mechanical Engineering and Applied Mechanics, Philadelphia, PA 19104-6315, USA
| | - Zongyuan Chen
- Department of Mechanical Engineering and Applied Mechanics, Philadelphia, PA 19104-6315, USA
| | - William R. Abrams
- Department of Basic Sciences, New York University College of Dentistry, New York, 10010, USA
| | - Daniel Malamud
- Department of Basic Sciences, New York University College of Dentistry, New York, 10010, USA
- Department of Medicine, NYU School of Medicine, New York, 10010, USA
| | | | - Haim H. Bau
- Department of Mechanical Engineering and Applied Mechanics, Philadelphia, PA 19104-6315, USA
| |
Collapse
|
39
|
Kartalov EP, Lin DH, Lee DT, Anderson WF, Taylor CR, Scherer A. Internally calibrated quantification of protein analytes in human serum by fluorescence immunoassays in disposable elastomeric microfluidic devices. Electrophoresis 2008; 29:5010-6. [PMID: 19130581 PMCID: PMC2737359 DOI: 10.1002/elps.200800297] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Herein we report on reliable reproducible quantification of protein analytes in human serum by fluorescence sandwich immunoassays in disposable PDMS microfluidic chips. The system requires 1,000 times less sample than typical clinical blood tests and is specifically shown to measure ferritin down to 250 pM in human serum. The in-built calibration method of spiking the serum with known concentrations of commercially available antigen avoids common sources of error and improves the reliability of the test results. The reported microfluidic system is an important new tool for fundamental scientific research, offering sensitive immunoassay measurements in small but complex biosamples. The system is also a further step towards comprehensive affordable "point-of-care" biomedical diagnostics.
Collapse
Affiliation(s)
- Emil P Kartalov
- Department of Pathology, Keck School of Medicine, University of Southern California, Los Angeles, CA 90089-9092, USA.
| | | | | | | | | | | |
Collapse
|
40
|
Myers FB, Lee LP. Innovations in optical microfluidic technologies for point-of-care diagnostics. LAB ON A CHIP 2008; 8:2015-31. [PMID: 19023464 DOI: 10.1039/b812343h] [Citation(s) in RCA: 266] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Despite a growing focus from the academic community, the field of microfluidics has yet to produce many commercial devices for point-of-care (POC) diagnostics. One of the main reasons for this is the difficulty in producing low-cost, sensitive, and portable optical detection systems. Although electrochemical methods work well for certain applications, optical detection is generally regarded as superior and is the method most widely employed in laboratory clinical chemistry. Conventional optical systems, however, are costly, require careful alignment, and do not translate well to POC devices. Furthermore, many optical detection paradigms such as absorbance and fluorescence suffer at smaller geometries because the optical path length through the sample is shortened. This review examines the innovative techniques which have recently been developed to address these issues. We highlight microfluidic diagnostic systems which demonstrate practical integration of sample preparation, analyte enrichment, and optical detection. We also examine several emerging detection paradigms involving nanoengineered materials which do not suffer from the same miniaturization disadvantages as conventional measurements.
Collapse
Affiliation(s)
- Frank B Myers
- Biomolecular Nanotechnology Center, Berkeley Sensor and Actuator Center, Department of Bioengineering, University of California, Berkeley, CA 94720, USA
| | | |
Collapse
|
41
|
Fujioka K, Hiruoka M, Sato K, Manabe N, Miyasaka R, Hanada S, Hoshino A, Tilley RD, Manome Y, Hirakuri K, Yamamoto K. Luminescent passive-oxidized silicon quantum dots as biological staining labels and their cytotoxicity effects at high concentration. NANOTECHNOLOGY 2008; 19:415102. [PMID: 21832637 DOI: 10.1088/0957-4484/19/41/415102] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Semiconductor quantum dots (QDs) hold some advantages over conventional organic fluorescent dyes. Due to these advantages, they are becoming increasingly popular in the field of bioimaging. However, recent work suggests that cadmium based QDs affect cellular activity. As a substitute for cadmium based QDs, we have developed photoluminescent stable silicon quantum dots (Si-QDs) with a passive-oxidation technique. Si-QDs (size: 6.5 ± 1.5 nm) emit green light, and they have been used as biological labels for living cell imaging. In order to determine the minimum concentration for cytotoxicity, we investigated the response of HeLa cells. We have shown that the toxicity of Si-QDs was not observed at 112 µg ml(-1) and that Si-QDs were less toxic than CdSe-QDs at high concentration in mitochondrial assays and with lactate dehydrogenase (LDH) assays. Especially under UV exposure, Si-QDs were more than ten times safer than CdSe-QDs. We suggest that one mechanism for the cytotoxicity is that Si-QDs can generate oxygen radicals and these radicals are associated with membrane damages. This work has demonstrated the suitability of Si-QDs for bioimaging in lower concentration, and their cytotoxicity and one toxicity mechanism at high concentration.
Collapse
Affiliation(s)
- Kouki Fujioka
- International Clinical Research Centre, Research Institute, International Medical Centre of Japan, Japan. Institute of DNA Medicine, Research Centre for Medical Sciences, Jikei University School of Medicine, Japan
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Single cell level detection of Escherichia coli in microfluidic device. Biosens Bioelectron 2008; 23:1303-6. [DOI: 10.1016/j.bios.2007.11.013] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2007] [Revised: 11/21/2007] [Accepted: 11/23/2007] [Indexed: 11/18/2022]
|