1
|
WS 2 nanosheets-based electrochemical biosensor for highly sensitive detection of tumor marker miRNA-4484. Talanta 2024; 274:125965. [PMID: 38552480 DOI: 10.1016/j.talanta.2024.125965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 03/18/2024] [Accepted: 03/20/2024] [Indexed: 05/04/2024]
Abstract
In this paper, a few-layer WS2 nanosheets-based electrochemical biosensor was fabricated for the highly sensitive detection of breast cancer tumor marker miRNA-4484. Firstly, few-layer WS2 nanosheets were prepared by shear stripping and characterized by SEM, TEM, AFM and UV spectrophotometer. After modification of few-layer WS2 nanosheets on the electrode surface, the miRNA probe was fixed on the few-layer WS2 nanosheets by polycytosine (PolyC). Then short-chain miRNA containing PolyC was used as the blocking agent to close the excess active sites on the surface of WS2 nanosheets to complete the fabrication of the sensor biosensing interface. Finally, the current changes caused by the specific binding of miRNA-4484 to the probe were analyzed by differential pulse voltammetry (DPV). The results showed that the sensor had a good linear relationship for the detection of miRNA-4484 in the concentration range of 1 aM-100 fM, and the detection limit was as low as 1.61 aM. In addition, the electrochemical sensor had excellent selectivity, stability and reproducibility. The artificial sample tests indicated that the developed biosensors have the potential for clinical application in the future.
Collapse
|
2
|
A comprehensive guide to extract information from extracellular vesicles: a tutorial review towards novel analytical developments. Anal Chim Acta 2024; 1302:342473. [PMID: 38580402 DOI: 10.1016/j.aca.2024.342473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 03/11/2024] [Accepted: 03/12/2024] [Indexed: 04/07/2024]
Abstract
In the medical field, extracellular vesicles (EVs) are gaining importance as they act as cells mediators. These are phospholipid bilayer vesicles and contain crucial biochemical information about their mother cells being carrier of different biomolecules such as small molecules, proteins, lipids, and nucleic acids. After release into the extracellular matrix, they enter the systemic circulation and can be found in all human biofluids. Since EVs reflect the state of the cell of origin, there is exponential attention as potential source of new circulating biomarkers for liquid biopsy. The use of EVs in clinical practice faces several challenges that need to be addressed: these include the standardization of lysis protocols, the availability of low-cost reagents and the development of analytical tools capable of detecting biomarkers. The process of lysis is a crucial step that can impact all subsequent analyses, towards the development of novel analytical strategies. To aid researchers to support the evolution of measurement science technology, this tutorial review evaluates and discuss the most commonly protocols used to characterize the contents of EVs, including their advantages and disadvantages in terms of experimental procedures, time and equipment. The purpose of this tutorial review is to offer practical guide to researchers which are intended to develop novel analytical approaches. Some of the most significant applications are considered, highlighting their main characteristics divided per mechanism of action. Finally, comprehensive tables which provide an overview at a glance are provided to readers.
Collapse
|
3
|
Paper-based electrochemical device for early detection of integrin αvβ6 expressing tumors. Commun Chem 2024; 7:60. [PMID: 38514757 PMCID: PMC10957923 DOI: 10.1038/s42004-024-01144-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 03/11/2024] [Indexed: 03/23/2024] Open
Abstract
Despite progress in the prevention and diagnosis of cancer, current technologies for tumor detection present several limitations including invasiveness, toxicity, inaccuracy, lengthy testing duration and high cost. Therefore, innovative diagnostic techniques that integrate knowledge from biology, oncology, medicinal and analytical chemistry are now quickly emerging in the attempt to address these issues. Following this approach, here we developed a paper-based electrochemical device for detecting cancer-derived Small Extracellular Vesicles (S-EVs) in fluids. S-EVs were obtained from cancer cell lines known to express, at a different level, the αvβ6 integrin receptor, a well-established hallmark of numerous epithelial cancer types. The resulting biosensor turned out to recognize αvβ6-containing S-EVs down to a limit of 0.7*103 S-EVs/mL with a linear range up to 105 S-EVs /mL, and a relative standard deviation of 11%, thus it may represent a novel opportunity for αvβ6 expressing cancers detection.
Collapse
|
4
|
Ultra-stable threose nucleic acid-based biosensors for rapid and sensitive nucleic acid detection and in vivo imaging. Acta Biomater 2024; 177:472-485. [PMID: 38296012 DOI: 10.1016/j.actbio.2024.01.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Revised: 01/04/2024] [Accepted: 01/22/2024] [Indexed: 02/13/2024]
Abstract
The human genome's nucleotide sequence variation, such as single nucleotide mutations, can cause numerous genetic diseases. However, detecting nucleic acids accurately and rapidly in complex biological samples remains a major challenge. While natural deoxyribonucleic acid (DNA) has been used as biorecognition probes, it has limitations like poor specificity, reproducibility, nuclease-induced enzymatic degradation, and reduced bioactivity on solid surfaces. To address these issues, we introduce a stable and reliable biosensor called graphene oxide (GO)- threose nucleic acid (TNA). It comprises chemically modified TNA capture probes on GO for detecting and imaging target nucleic acids in vitro and in vivo, distinguishing single nucleobase mismatches, and monitoring dynamic changes in target microRNA (miRNA). By loading TNA capture probes onto the GO substrate, the GO-TNA sensing platform for nucleic acid detection demonstrates a significant 88-fold improvement in the detection limit compared to TNA probes alone. This platform offers a straightforward preparation method without the need for costly and labor-intensive isolation procedures or complex chemical reactions, enabling real-time analysis. The stable TNA-based GO sensing nanoplatform holds promise for disease diagnosis, enabling rapid and accurate detection and imaging of various disease-related nucleic acid molecules at the in vivo level. STATEMENT OF SIGNIFICANCE: The study's significance lies in the development of the GO-TNA biosensor, which addresses limitations in nucleic acid detection. By utilizing chemically modified nucleic acid analogues, the biosensor offers improved reliability and specificity, distinguishing single nucleobase mismatches and avoiding false signals. Additionally, its ability to detect and image target nucleic acids in vivo facilitates studying disease mechanisms. The simplified preparation process enhances practicality and accessibility, enabling real-time analysis. The biosensor's potential applications extend beyond healthcare, contributing to environmental analysis and food safety. Overall, this study's findings have substantial implications for disease diagnosis, biomedical research, and diverse applications, advancing nucleic acid detection and its impact on various fields.
Collapse
|
5
|
DNA/RNA-based electrochemical nanobiosensors for early detection of cancers. Crit Rev Clin Lab Sci 2024:1-23. [PMID: 38450458 DOI: 10.1080/10408363.2024.2321202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 02/16/2024] [Indexed: 03/08/2024]
Abstract
Nucleic acids, like DNA and RNA, serve as versatile recognition elements in electrochemical biosensors, demonstrating notable efficacy in detecting various cancer biomarkers with high sensitivity and selectivity. These biosensors offer advantages such as cost-effectiveness, rapid response, ease of operation, and minimal sample preparation. This review provides a comprehensive overview of recent developments in nucleic acid-based electrochemical biosensors for cancer diagnosis, comparing them with antibody-based counterparts. Specific examples targeting key cancer biomarkers, including prostate-specific antigen, microRNA-21, and carcinoembryonic antigen, are highlighted. The discussion delves into challenges and limitations, encompassing stability, reproducibility, interference, and standardization issues. The review suggests future research directions, exploring new nucleic acid recognition elements, innovative transducer materials and designs, novel signal amplification strategies, and integration with microfluidic devices or portable instruments. Evaluating these biosensors in clinical settings using actual samples from cancer patients or healthy donors is emphasized. These sensors are sensitive and specific at detecting non-communicable and communicable disease biomarkers. DNA and RNA's self-assembly, programmability, catalytic activity, and dynamic behavior enable adaptable sensing platforms. They can increase biosensor biocompatibility, stability, signal transduction, and amplification with nanomaterials. In conclusion, nucleic acids-based electrochemical biosensors hold significant potential to enhance cancer detection and treatment through early and accurate diagnosis.
Collapse
|
6
|
Detection of miR-155 Using Peptide Nucleic Acid at Physiological-like Conditions by Surface Plasmon Resonance and Bio-Field Effect Transistor. BIOSENSORS 2024; 14:79. [PMID: 38391998 PMCID: PMC10887097 DOI: 10.3390/bios14020079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 01/21/2024] [Accepted: 01/30/2024] [Indexed: 02/24/2024]
Abstract
MicroRNAs are small ribonucleotides that act as key gene regulators. Their altered expression is often associated with the onset and progression of several human diseases, including cancer. Given their potential use as biomarkers, there is a need to find detection methods for microRNAs suitable for use in clinical setting. Field-effect-transistor-based biosensors (bioFETs) appear to be valid tools to detect microRNAs, since they may reliably quantitate the specific binding between the immobilized probe and free target in solution through an easily detectable electrical signal. We have investigated the detection of human microRNA 155 (miR-155) using an innovative capturing probe constituted by a synthetic peptide nucleic acid (PNA), which has the advantage to form a duplex even at ionic strengths approaching the physiological conditions. With the aim to develop an optimized BioFET setup, the interaction kinetics between miR-155 and the chosen PNA was preliminarily investigated by using surface plasmon resonance (SPR). By exploiting both these results and our custom-made bioFET system, we were able to attain a low-cost, real-time, label-free and highly specific detection of miR-155 in the nano-molar range.
Collapse
|
7
|
Tandem CRISPR nucleases-based lateral flow assay for amplification-free miRNA detection via the designed "locked RNA/DNA" as fuels. Talanta 2024; 266:124995. [PMID: 37524043 DOI: 10.1016/j.talanta.2023.124995] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 06/28/2023] [Accepted: 07/25/2023] [Indexed: 08/02/2023]
Abstract
Currently, available biosensors based on CRISPR/Cas typically depend on coupling with nucleic acid amplification technologies to enhance their sensitivity. However, this approach often involves intricate amplification processes, which could be time-consuming and susceptible to contamination. In addition, signal readouts often require sophisticated and cumbersome equipment, obstructing the applicability of CRISPR/Cas assays in resource-limited regions. Herein, a tandem CRISPR/Cas13a/Cas12a mechanism (tanCRISPR) has been developed via the designed "Locked RNA/DNA" probe as fuels for the trans-cleavage nucleic acid of Cas13a and activated nucleic acid of Cas12a. Meanwhile, a lateral flow assay (LFA) is designed to combine with this tandem CRISPR/Cas13a/Cas12a mechanism (termed tanCRISPR-LFA), realizing the portable monitoring of miRNA-21. The tanCRISPR could realize the limit of detection at pM levels (266 folds lower than Cas13a-based miRNA testing alone) without the resort to target amplification procedures. Furthermore, the miRNA-21 levels of MDA-MB-231 cell extracts are sensed by tanCRISPR-LFA, which is comparable to qRT-PCR. With the virtues of portability, rapidity, sensitivity, and low cost, tanCRISPR-LFA is amenable for CRISPR/Cas-based biosensing and potential applications in the clinical diagnosis of miRNA-associated diseases.
Collapse
|
8
|
Point-of-Care Testing for the Detection of MicroRNAs: Towards Liquid Biopsy on a Chip. Angew Chem Int Ed Engl 2023; 62:e202309135. [PMID: 37672490 DOI: 10.1002/anie.202309135] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/23/2023] [Accepted: 09/06/2023] [Indexed: 09/08/2023]
Abstract
Point-of-care (PoC) testing is revolutionizing the healthcare sector improving patient care in daily hospital practice and allowing reaching even remote geographical areas. In the frame of cancer management, the design and validation of PoC enabling the non-invasive, rapid detection of cancer markers is urgently required to implement liquid biopsy in clinical practice. Therefore, focusing on stable blood-based markers with high-specificity, such as microRNAs, is of crucial importance. In this work, we highlight the potential impact of circulating microRNAs detection on cancer management and the crucial role of PoC testing devices, especially for low-income countries. A detailed discussion about the challenges that should be faced to promote the technological transfer and clinical use of these tools has been added, to provide the readers with a complete overview of potentialities and current limitations.
Collapse
|
9
|
Electrochemical nucleic acid sensors: Competent pathways for mobile molecular diagnostics. Biosens Bioelectron 2023; 237:115407. [PMID: 37295136 DOI: 10.1016/j.bios.2023.115407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 05/10/2023] [Accepted: 05/15/2023] [Indexed: 06/12/2023]
Abstract
Electrochemical nucleic acid biosensor has demonstrated great promise in clinical diagnostic tests, mainly because of its flexibility, high efficiency, low cost, and easy integration for analytical applications. Numerous nucleic acid hybridization-based strategies have been developed for the design and construction of novel electrochemical biosensors for diagnosing genetic-related diseases. This review describes the advances, challenges, and prospects of electrochemical nucleic acid biosensors for mobile molecular diagnosis. Specifically, the basic principles, sensing elements, applications in diagnosis of cancer and infectious diseases, integration with microfluidic technology and commercialization are mainly included in this review, aiming to provide new insights and directions for the future development of electrochemical nucleic acid biosensors.
Collapse
|
10
|
MicroRNA electrochemical biosensors for pancreatic cancer. Clin Chim Acta 2023; 548:117472. [PMID: 37419303 DOI: 10.1016/j.cca.2023.117472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 07/03/2023] [Accepted: 07/04/2023] [Indexed: 07/09/2023]
Abstract
Pancreatic cancer (PC) is one of the deadliest cancers worldwide. MicroRNAs (miRs) are sensitive molecular diagnostic tools that can serve as highly accurate biomarkers in many disease states in general and cancer specifically. MiR-based electrochemical biosensors can be easily and inexpensively manufactured, making them suitable for clinical use and mass production for point-of-care use. This paper reviews nanomaterial-enhanced miR-based electrochemical biosensors in pancreatic cancer detection, analyzing both labeled and label-free approaches, as well as enzyme-based and enzyme-free methods.
Collapse
|
11
|
Label-Free Electrochemical Methods for Disease Detection. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2023; 16:49-69. [PMID: 36854209 DOI: 10.1146/annurev-anchem-091622-085754] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Label-free electrochemical biosensing leverages the advantages of label-free techniques, low cost, and fewer user steps, with the sensitivity and portability of electrochemical analysis. In this review, we identify four label-free electrochemical biosensing mechanisms: (a) blocking the electrode surface, (b) allowing greater access to the electrode surface, (c) changing the intercalation or electrostatic affinity of a redox probe to a biorecognition unit, and (d) modulating ion or electron transport properties due to conformational and surface charge changes. Each mechanism is described, recent advancements are summarized, and relative advantages and disadvantages of the techniques are discussed. Furthermore, two avenues for gaining further diagnostic information from label-free electrochemical biosensors, through multiplex analysis and incorporating machine learning, are examined.
Collapse
|
12
|
Electrochemical microfluidic paper-based analytical devices for cancer biomarker detection: From 2D to 3D sensing systems. Talanta 2023; 257:124370. [PMID: 36858013 DOI: 10.1016/j.talanta.2023.124370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 02/06/2023] [Accepted: 02/13/2023] [Indexed: 02/18/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) offer a unique possibility for a cost-effective portable and rapid detection of a wide range of small molecules and macromolecules and even microorganisms. In this line, electrochemical detection methods are key techniques for the qualitative analysis of different types of ligands. The electrochemical sensing μPADs have been devised for the rapid, accurate, and quantitative detection of oncomarkers through two-/three-dimensional (2D/3D) approaches. The 2D μPADs were first developed and then transformed into 3D systems via folding and/or twisting of paper. The microfluidic channels and connections were created within the layers of paper. Based on the fabrication methods, 3D μPADs can be classified into origami and stacking devices. Various fabrication methods and materials have been used to create hydrophilic channels in μPADs, among which the wax printing technique is the most common method in fabricating μPADs. In this review, we discuss the fabrication and design strategies of μPADs, elaborate on their detection modes, and highlight their applications in affinity-based electrochemical μPADs methods for the detection of oncomarkers.
Collapse
|
13
|
Studies on the application of single-stranded DNA and PNA probes for electrochemical detection of miRNA 141. Bioelectrochemistry 2023; 150:108363. [PMID: 36608369 DOI: 10.1016/j.bioelechem.2022.108363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 12/09/2022] [Accepted: 12/28/2022] [Indexed: 12/31/2022]
Abstract
The abnormal concentration of microRNAs (miRNAs) can be associated with occurrence of various diseases including cancer, cardiovascular and neurodegenerative, hence they can be considered as potential biomarkers. An attractive approach could be the application of electrochemical methods, particularly where hybridization event between single-stranded deoxyribonucleic acid (ssDNA) or peptide-nucleic acid (PNA) with miRNA strand happens. Recently, the use of various nanomaterials such as gold nanoparticles, graphene oxide, quantum dots as well as catalyzed hairpin assembly or hybridization chain reaction were proposed to further enhance the performance of elaborated sensors. Herein, we present the studies on selection of receptor layer composition for detection of miRNA 141. The possibility of formation of receptor layer and further duplex monolayer between ssDNA or PNA with miRNA was analyzed by atomic force microscopy (AFM) technique. The interaction of ssDNA and PNA probes with miRNA was further verified using surface plasmon resonance (SPR) and quartz - crystal microbalance (QCM) techniques. On the basis of impedance spectroscopy it was shown that the use of unlabelled ssDNA as receptor layer provided 0.1 pM detection limit. This shows that proposed biosensor that is simple in preparation and use is an attractive alternative to other recently presented approaches.
Collapse
|
14
|
Design of a printed electrochemical strip towards miRNA-21 detection in urine samples: optimization of the experimental procedures for real sample application. Anal Bioanal Chem 2023:10.1007/s00216-023-04659-x. [PMID: 37000212 PMCID: PMC10328899 DOI: 10.1007/s00216-023-04659-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 02/28/2023] [Accepted: 03/16/2023] [Indexed: 04/01/2023]
Abstract
MicroRNAs (miRNAs) are clinical biomarkers for various human diseases, including cancer. They have been found in liquid biopsy samples, including various bodily fluids. They often play an important role in the early diagnosis and prognosis of cancer, and the development of simple and effective analytical methods would be of pivotal importance for the entire community. The determination of these targets may be affected by the different physicochemical parameters of the specimen of interest. In this work, an electrochemical detection platform for miRNA based on a screen-printed gold electrode was developed. In the present study, miRNA-21 was selected as a model sequence, due to its role in prostate, breast, colon, pancreatic, and liver cancers. A DNA sequence modified with methylene blue (MB) was covalently bound to the electrochemical strip and used to detect the selected target miRNA-21. After optimization of selected parameters in standard solutions, including the study of the effect of pH, the presence of interferent species, and NaCl salt concentration in the background, the application of square-wave voltammetry (SWV) technique allowed the detection of miRNA-21 down to a limit in the order of 2 nM. The developed device was then applied to several urine samples. In this case too, the device showed high selectivity in the presence of the complex matrix, satisfactory repeatability, and a limit of detection in the order of magnitude of nM, similarly as what observed in standard solutions.
Collapse
|
15
|
The immunogenic involvement of miRNA-492 in mycoplasma pneumoniae infection in pediatric patients. J Pediatr (Rio J) 2023; 99:187-192. [PMID: 36195304 PMCID: PMC10031331 DOI: 10.1016/j.jped.2022.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 07/06/2022] [Accepted: 07/07/2022] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE This study aimed to evaluate the role of miRNA-492 in the progression of mycoplasma pneumoniae (MP) infection in pediatric patients. METHODS Forty-six children admitted to the present study's hospital and diagnosed with mycoplasma pneumonia were recruited as the study group from March 2018 to August 2019, and 40 healthy children were selected as the control group. RESULTS The expression levels of miRNA-492, TNF-α, IL-6 and IL-18 in the study group were significantly higher than those in the control group (p < 0.05). There was no significant correlation between miRNA-492 and most of the immune-correlated indicators in the study group, except for IL-6, IL-18 and HMGB1. Meanwhile, overexpression of miRNA-492 increased IL-6 secretion in PMA-activated monocytes (p < 0.01). CONCLUSION The present study's results suggested that miRNA-492 might play a role in the pathogenesis of mycoplasma pneumoniae pneumonia in children by regulating the secretion of immune-inflammatory factors such as IL-6 and IL-18 in the mononuclear macrophages.
Collapse
|
16
|
Smartphone-based colorimetric detection of cardiac troponin T via label-free aptasensing. Biosens Bioelectron 2023; 222:114938. [PMID: 36462432 DOI: 10.1016/j.bios.2022.114938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 11/17/2022] [Accepted: 11/18/2022] [Indexed: 11/23/2022]
Abstract
We report an aptasensing platform for the detection of cardiac troponin T (cTnT) in the immediate and early phases of acute myocardial infarction (AMI). High-flow filter paper was used to fabricate a microfluidic paper-based analytical device (μ-PAD), which was further modified with gold-decorated polystyrene microparticles functionalized with a highly specific cTnT aptamer. Herein, cTnT detection is presented in two linear ranges (0.01-0.8 μg/ml and 6.25-50 μg/ml) with an LoD of 3.9X10-4 μg/ml, which is in agreement with reference values determined by the American Heart Association. The proposed platform showed remarkable selectivity against AMI-associated cardiac biomarkers such as TNF-alpha, interleukin-6, cardiac troponin I, and reactive protein-C. This aptasensor is a label-free assay that relies only on smartphone-based image analysis and takes less processing time in comparison with traditional methods like ELISA. Furthermore, it exhibits outstanding stability over 23 days when devices are stored at 4 °C. The reported platform is a stable and cost-effective method for the on-site and user-friendly detection of cTnT in normal saline buffer and diluted human serum.
Collapse
|
17
|
MicroRNA biosensors for detection of gastrointestinal cancer. Clin Chim Acta 2023; 541:117245. [PMID: 36754191 DOI: 10.1016/j.cca.2023.117245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 12/27/2022] [Accepted: 02/01/2023] [Indexed: 02/08/2023]
Abstract
Gastrointestinal (GI) cancers are one of the most common causes of cancer-related mortality. The discovery of microRNAs (miRs) and their unique role in cancer and other diseases has prompted the development of highly sensitive molecular diagnostic tools using nanomaterials as sensitive and specific biosensors. Among these, electrochemical biosensors, which are based on a simple and inexpensive design, make them desirable in clinical applications as well as a mass-produced point-of-care device. We review miR-based electrochemical biosensors in GI cancer and examine the use of nanoparticles in the evolving development of miR-based biosensors. Among these, a number of approaches including redox labeled probes, catalysts, redox intercalating agents and free redox indicators are highlighted for use in electrochemical biosensor technology.
Collapse
|
18
|
Nanomechanical assay for ultrasensitive and rapid detection of SARS-CoV-2 based on peptide nucleic acid. NANO RESEARCH 2023; 16:1183-1195. [PMID: 35610981 PMCID: PMC9118818 DOI: 10.1007/s12274-022-4333-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 03/14/2022] [Accepted: 03/16/2022] [Indexed: 05/14/2023]
Abstract
UNLABELLED The massive global spread of the COVID-19 pandemic makes the development of more effective and easily popularized assays critical. Here, we developed an ultrasensitive nanomechanical method based on microcantilever array and peptide nucleic acid (PNA) for the detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) RNA. The method has an extremely low detection limit of 0.1 fM (105 copies/mL) for N-gene specific sequence (20 bp). Interestingly, it was further found that the detection limit of N gene (pharyngeal swab sample) was even lower, reaching 50 copies/mL. The large size of the N gene dramatically enhances the sensitivity of the nanomechanical sensor by up to three orders of magnitude. The detection limit of this amplification-free assay method is an order of magnitude lower than RT-PCR (500 copies/mL) that requires amplification. The non-specific signal in the assay is eliminated by the in-situ comparison of the array, reducing the false-positive misdiagnosis rate. The method is amplification-free and label-free, allowing for accurate diagnosis within 1 h. The strong specificity and ultra-sensitivity allow single base mutations in viruses to be distinguished even at very low concentrations. Also, the method remains sensitive to fM magnitude lung cancer marker (miRNA-155). Therefore, this ultrasensitive, amplification-free and inexpensive assay is expected to be used for the early diagnosis of COVID-19 patients and to be extended as a broad detection tool. ELECTRONIC SUPPLEMENTARY MATERIAL Supplementary material (experimental section, N gene sequences and all nucleic acid sequences used in the study, Figs. S1-S6, and Tables S1-S3) is available in the online version of this article at 10.1007/s12274-022-4333-3.
Collapse
|
19
|
Paper-Based Biosensors for the Detection of Nucleic Acids from Pathogens. BIOSENSORS 2022; 12:bios12121094. [PMID: 36551061 PMCID: PMC9776365 DOI: 10.3390/bios12121094] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 11/14/2022] [Accepted: 11/18/2022] [Indexed: 05/17/2023]
Abstract
Paper-based biosensors are microfluidic analytical devices used for the detection of biochemical substances. The unique properties of paper-based biosensors, including low cost, portability, disposability, and ease of use, make them an excellent tool for point-of-care testing. Among all analyte detection methods, nucleic acid-based pathogen detection offers versatility due to the ease of nucleic acid synthesis. In a point-of-care testing context, the combination of nucleic acid detection and a paper-based platform allows for accurate detection. This review offers an overview of contemporary paper-based biosensors for detecting nucleic acids from pathogens. The methods and limitations of implementing an integrated portable paper-based platform are discussed. The review concludes with potential directions for future research in the development of paper-based biosensors.
Collapse
|
20
|
Nanomaterials and paper-based electrochemical devices: merging strategies for fostering sustainable detection of biomarkers. J Mater Chem B 2022; 10:9021-9039. [PMID: 35899594 DOI: 10.1039/d2tb00387b] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
In the last few decades, nanomaterials have made great advances in the biosensor field, thanks to their ability to enhance several key issues of biosensing analytical tools, namely, sensitivity, selectivity, robustness, and reproducibility. The recent trend of sustainability has boosted the progress of novel and eco-designed electrochemical paper-based devices to detect easily the target analyte(s) with high sensitivity in complex matrices. The huge attention given by the scientific community and industrial sectors to paper-based devices is ascribed to the numerous advantages of these cost-effective analytical tools, including the absence of external equipment for solution flow, thanks to the capillary force of paper, the fabrication of reagent-free devices, because of the loading of reagents on the paper, and the easy multistep analyses by using the origami approach. Besides these features, herein we highlight the multifarious aspects of the nanomaterials such as (i) the significant enlargement of the electroactive surface area as well as the area available for the desired chemical interactions, (ii) the capability of anchoring biorecognition elements on the electrode surface on the paper matrix, (iii) the improvement of the conductivity of the cellulose matrix, (iv) the functionality of photoelectrochemical properties within the cellulose matrix, and (v) the improvement of electrochemical capabilities of conductive inks commonly used for electrode printing on the paper support, for the development of a new generation of paper-based electrochemical biosensors applied in the biomedical field. The state of the art over the last ten years has been analyzed highlighting the various functionalities that arise from the integration of nanomaterials with paper-based electrochemical biosensors for the detection of biomarkers.
Collapse
|
21
|
Printed Electrochemical Strip for the Detection of miRNA-29a: A Possible Biomarker Related to Alzheimer’s Disease. Anal Chem 2022; 94:15558-15563. [PMID: 36318963 PMCID: PMC9670028 DOI: 10.1021/acs.analchem.2c03542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
![]()
The development of electrochemical strips, as extremely
powerful
diagnostic tools, has received much attention in the field of sensor
analysis and, in particular, the detection of nucleic acids in complex
matrixes is a hot topic in the electroanalytical area, especially
when directed toward the development of emerging technologies, for
the purpose of facilitating personal healthcare. One of the major
diseases for which early diagnosis is crucial is represented by Alzheimer’s
disease (AD). AD is a progressive neurodegenerative disease, and it
is the most common cause of dementia worldwide. In this context microRNAs
(miRNAs), which are small noncoding RNAs, have recently been highlighted
for their promising role as biomarkers for early diagnosis. In particular,
miRNA-29 represents a class of miRNAs known to regulate pathogenesis
of AD. In this work we developed an electrochemical printed strip
for the detection of miRNA-29a at low levels. The architecture was
characterized by the presence of gold nanoparticles (AuNPs) and an
anti-miRNA-29a probe labeled with a redox mediator. The novel analytical
tool has been characterized with microscale thermophoresis and electrochemical
methods, and it has been optimized by selection of the most appropriate
probe density to detect low target concentration. The present tool
was capable to detect miRNA-29a both in standard solution and in serum,
respectively, down to 0.15 and 0.2 nM. The platform highlighted good
repeatability (calculated as the relative standard deviation) of ca.
10% and satisfactory selectivity in the presence of interfering species.
This work has the objective to open a way for the study and possible
early diagnosis of a physically and socially devastating disease such
as Alzheimer’s. The results demonstrate the suitability of
this approach in terms of ease of use, time of production, sensitivity,
and applicability.
Collapse
|
22
|
Liquid Biopsy beyond Cancer: A miRNA Detection in Serum with Electrochemical Chip for Non‐Invasive Coeliac Disease Diagnosis. ADVANCED NANOBIOMED RESEARCH 2022. [DOI: 10.1002/anbr.202200015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
23
|
Contemporary nanocellulose-composites: A new paradigm for sensing applications. Carbohydr Polym 2022; 298:120052. [DOI: 10.1016/j.carbpol.2022.120052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 08/24/2022] [Accepted: 08/25/2022] [Indexed: 01/21/2023]
|
24
|
Shared-probe system: An accurate, low-cost and general enzyme-assisted DNA probe system for detection of genetic mutation. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.09.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
25
|
Paper-based biosensors for cancer diagnostics. TRENDS IN CHEMISTRY 2022. [DOI: 10.1016/j.trechm.2022.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
26
|
The recent development of nanomaterials enhanced paper-based electrochemical analytical devices. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116140] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
27
|
Metal‐free phthalimide‐labeled peptide nucleic acids for electrochemical biosensing applications. ELECTROCHEMICAL SCIENCE ADVANCES 2022. [DOI: 10.1002/elsa.202100164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
28
|
Continuous monitoring of molecular biomarkers in microfluidic devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 187:295-333. [PMID: 35094779 DOI: 10.1016/bs.pmbts.2021.07.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
The ability to monitor molecular targets is crucial in fields ranging from healthcare to industrial processing to environmental protection. Devices employing biomolecules to achieve this goal are called biosensors. Over the last half century researchers have developed dozens of different biosensor approaches. In this chapter we analyze recent advances in the biosensing field aiming at adapting these to the problem of continuous molecular monitoring in complex sample streams, and how the merging of these sensors with lab-on-a-chip technologies would be beneficial to both. To do so we discuss (1) the components that comprise a biosensor, (2) the challenges associated with continuous molecular monitoring in complex sample streams, (3) how different sensing strategies deal with (or fail to deal with) these challenges, and (4) the implementation of these technologies into lab-on-a-chip architectures.
Collapse
|
29
|
Advanced nanoengineered-customized point-of-care tools for prostate-specific antigen. Mikrochim Acta 2021; 189:27. [PMID: 34905090 DOI: 10.1007/s00604-021-05127-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 12/02/2021] [Indexed: 01/06/2023]
Abstract
Change in the level of human prostate-specific antigen (PSA) is a major element in the development and progression of prostate cancer (PCa). Most of the methodologies are currently restricted to their application in routine clinical screening due to the scarcity of adequate screening tools, false reading, long assay time, and cost. Innovative techniques and the integration of knowledge from a variety of domains, such as materials science and engineering, are needed to provide sustainable solutions. The convergence of precision point-of-care (POC) diagnostic techniques, which allow patients to respond in real time to changes in PSA levels, provides promising possibilities for quantitative and quantitative detection of PSA. This solution could be interesting and relevant for use in PCa diagnosis at the POC. The approaches enable low-cost real-time detection and are simple to integrate into user-friendly sensor devices. This review focuses on the investigations, prospects, and challenges associated with integrating engineering sciences with cancer biology to develop nanotechnology-based tools for PCa diagnosis. This article intends to encourage the development of new nanomaterials to construct high-performance POC devices for PCa detection. Finally, the review concludes with closing remarks and a perspective forecast.
Collapse
|
30
|
Redox Host-Guest Nanosensors Installed with DNA Gatekeepers for Immobilization-Free and Ratiometric Electrochemical Detection of miRNA. SMALL METHODS 2021; 5:e2101072. [PMID: 34928007 DOI: 10.1002/smtd.202101072] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/24/2021] [Indexed: 06/14/2023]
Abstract
Electrochemical nanosensors by integrating functional nucleic acids and nanomaterials hold a great promise in the fast detection of biomarkers, yet the current systems possess limitations on the accessibility of target-probe and probe-electrode interactions and the repeatability of detection. Herein, a host-guest assembly strategy is developed to build redox nanosensors for an immobilization-free and ratiometric electrochemical detection system. Specifically, electroactive molecule (Em ) guests are loaded in porous hosts of polydopamine nanoparticles (MPDA) to act as dual-signal redox reporters. Hybrid DNA probes of G-quadruplex and a single-stranded anchor DNA are installed as gatekeepers for sealing the mesopores. Thereby, miRNA triggered Em release by strand displacement reactions and the homogeneous transportation of the hosts/guests to the electrode facilitate the generation of reference signal/response signal at different potentials. Concomitantly applied NIR irradiation boosts the electron transfer from MPDA to the electrode and results in a tenfold increase in the reference signal. Finally, the sensing system through the differential pulse voltammetry method achieves a highly repeatable detection (relative standard deviation 3.8%) of miRNA with a lower detection limit (362 × 10-15 m). This attractive system paves the way for rational designs of advanced electrochemical biosensors and smart diagnosis.
Collapse
|
31
|
An origami paper-based peptide nucleic acid device coupled with label-free DNAzyme probe hybridization chain reaction for prostate cancer molecular screening test. Anal Chim Acta 2021; 1186:339130. [PMID: 34756252 DOI: 10.1016/j.aca.2021.339130] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/25/2021] [Accepted: 09/28/2021] [Indexed: 11/27/2022]
Abstract
Prostate cancer associated 3 (PCA3) assay has been used to improve prostate cancer diagnosis and reduce unnecessary biopsies. In this work, we successfully developed a new PCA3 assay on an origami paper-based peptide nucleic acid device (oPAD). The PCA3 oPAD comprises an acrylic cassette and shutter slides to facilitate the molecular reaction and liquid control occurring on the paper surface. To quantify PCA3, a pyrrolidinyl peptide nucleic acid (acpcPNA) was immobilized onto the aldehyde-modified oPAD surface as a selective capture probe. A G-quadruplex (GQD) DNAzyme reporter probe was designed so that the PCA3 gene target binding triggered the hybridization chain reaction of the reporter probe, resulting in the accumulation of the GQD on the oPAD. The peroxidase activity of the GQD-hemin generated a deep green color of the oxidized ABTS substrate. Image analyses were performed in Adobe Photoshop CS6. The proposed oPAD was successfully applied in PCA3 detection ranges of 1-5 μM (r2 = 0.982) with a limit of detection of 0.5 μM. Our proposed oPAD was demonstrated to measure PCA3 samples in both urine matrix and human cancer cell lines. The results reveal the great potential of our origami paper-based platform to be an alternative approach for facile, rapid, and low-cost detection of PCA3 in real samples.
Collapse
|
32
|
Technological advances in electrochemical biosensors for the detection of disease biomarkers. Biomed Eng Lett 2021; 11:309-334. [PMID: 34466275 PMCID: PMC8396145 DOI: 10.1007/s13534-021-00204-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/13/2021] [Accepted: 08/20/2021] [Indexed: 12/15/2022] Open
Abstract
With an increasing focus on health in contemporary society, interest in the diagnosis, treatment, and prevention of diseases has grown rapidly. Accordingly, the demand for biosensors for the early diagnosis of disease is increasing. However, the measurement range of existing electrochemical sensors is relatively high, which is not suitable for early disease diagnosis, requiring the detection of small amounts of biocomponents. Various attempts have been made to overcome this and amplify the signal, including binding with various labeling molecules, such as DNA, enzymes, nanoparticles, and carbon materials. Efforts are also being made to increase the sensitivity of electrochemical sensors, and the combination of nanomaterials, materials, and biotechnology offers the potential to increase sensitivity in a variety of ways. Recent studies suggest that electrochemical sensors can be a powerful tool in providing comprehensive insights into the targeting and detection of disease-associated biomarkers. Significant advances in nanomaterial and biomolecule approaches for improved sensitivity have resulted in the development of electrochemical biosensors capable of detecting multiple biomarkers in real time in clinically relevant samples. In this review, we have discussed the recent studies on electrochemical sensors for detection of diseases such as diabetes, degenerative diseases, and cancer. Further, we have highlighted new technologies to improve sensitivity using various materials, including DNA, enzymes, nanoparticles, and carbon materials.
Collapse
|
33
|
Development, evaluation of the PNA RT-LAMP assay for rapid molecular detection of SARS-CoV-2. Sci Rep 2021; 11:20471. [PMID: 34650067 PMCID: PMC8516927 DOI: 10.1038/s41598-021-00041-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 10/05/2021] [Indexed: 12/22/2022] Open
Abstract
Dual-labeled PNA probe used RT-LAMP molecular rapid assay targeting SARS-CoV-2 ORF1ab and N genes was developed, and the analytical, clinical performances for detection of SARS-CoV-2 RNA extracted from clinical nasopharyngeal swab specimens were evaluated in this study. Data showed that this assay is highly specific for SARS-CoV-2, and the absolute detection limit is 1 genomic copy per microliter of viral RNA which can be considered to be comparable to gold-standard molecular diagnostic method real-time reverse transcriptase PCR. Both clinical sensitivity and specificity against a commercial real-time RT-PCR assay were determined as identical. In conclusion, the PNA RT-LAMP assay showed high analytical and clinical accuracy which are identical to real-time RT-PCR which has been routinely used for the detection of SARS-CoV-2.
Collapse
|
34
|
Microfluidic paper-based chips in rapid detection: Current status, challenges, and perspectives. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116371] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
35
|
Abstract
There is a growing interest in the development of portable, cost-effective, and easy-to-use biosensors for the rapid detection of diseases caused by infectious viruses: COVID-19 pandemic has highlighted the central role of diagnostics in response to global outbreaks. Among all the existing technologies, screen-printed electrodes (SPEs) represent a valuable technology for the detection of various viral pathogens. During the last five years, various nanomaterials have been utilized to modify SPEs to achieve convincing effects on the analytical performances of portable SPE-based diagnostics. Herein we would like to provide the readers a comprehensive investigation about the recent combination of SPEs and various nanomaterials for detecting viral pathogens. Manufacturing methods and features advances are critically discussed in the context of early-stage detection of diseases caused by HIV-1, HBV, HCV, Zika, Dengue, and Sars-CoV-2. A detailed table is reported to easily guide readers toward the "right" choice depending on the virus of interest.
Collapse
|
36
|
Nucleic Acid Integrated Technologies for Electrochemical Point‐of‐Care Diagnostics: A Comprehensive Review. ELECTROANAL 2021. [DOI: 10.1002/elan.202100309] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
37
|
Easy Surface Functionalization and Bioconjugation of Peptides as Capture Agents of a Microfluidic Biosensing Platform for Multiplex Assay in Serum. Bioconjug Chem 2021; 32:1593-1601. [PMID: 34114801 PMCID: PMC8382222 DOI: 10.1021/acs.bioconjchem.1c00146] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 05/28/2021] [Indexed: 12/11/2022]
Abstract
The development of assays for protein biomarkers in complex matrices is a demanding task that still needs implementation of new approaches. Antibodies as capture agents have been largely used in bioassays but their low stability, low-efficiency production, and cross-reactivity in multiplex approaches impairs their larger applications. Instead, synthetic peptides, even with higher stability and easily adapted amino acid sequences, still remain largely unexplored in this field. Here, we provide a proof-of-concept of a microfluidic device for direct detection of biomarker overexpression. The multichannel microfluidic polydimethylsiloxane (PDMS) device was first derivatized with PAA (poly(acrylic acid)) solution. CRP-1, VEGF-114, and ΦG6 peptides were preliminarily tested to respectively bind the biomarkers, C-reactive protein (CRP), vascular endothelial growth factor (VEGF), and tumor necrosis factor-alpha (TNF-α). Each PDMS microchannel was then respectively bioconjugated with a specific peptide (CRP-1, VEGF-114, or ΦG6) to specifically capture CRP, VEGF, and TNF-α. With such microdevices, a fluorescence bioassay has been set up with sensitivity in the nanomolar range, both in buffered solution and in human serum. The proposed multiplex assay worked with a low amount of sample (25 μL) and detected biomarker overexpression (above nM concentration), representing a noninvasive and inexpensive screening platform.
Collapse
|
38
|
An integrated electrochemical POCT platform for ultrasensitive circRNA detection towards hepatocellular carcinoma diagnosis. Biosens Bioelectron 2021; 192:113500. [PMID: 34280653 DOI: 10.1016/j.bios.2021.113500] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 07/09/2021] [Accepted: 07/11/2021] [Indexed: 02/06/2023]
Abstract
Hepatocellular carcinoma (HCC) is the fourth leading cause of cancer-related death. Circ-CDYL, one of the circular RNAs (circRNAs), is recognized as an independent marker for HCC early diagnosis. Point-of-care testing (POCT) of circRNA is essential and in great demand for clinical applications. Herein, we report a fully integrated electrochemical POCT platform for circRNA detection based on Au nanoflowers (AuNFs)/peptide nucleic acid (PNA) modified carbon-fiber microelectrode (CFME). PNA is applied as the recognition element, highly specified for a back-splice junction of circRNA. AuNFs increased active site for PNA probes, improving target-capturing efficiency at an ultralow level. The platform provides a linear range of 10 fM to 1 μM, with a detection limit as low as 3.29 fM. This biosensor demonstrates high specificity towards one-base mismatch and is stable for up to 24 days. The analytical performance has also been verified in human serum samples, demonstrating the potential utility in clinical POCT applications for HCC.
Collapse
|
39
|
Nanobioengineered Sensing Technologies Based on Cellulose Matrices for Detection of Small Molecules, Macromolecules, and Cells. BIOSENSORS 2021; 11:168. [PMID: 34073910 PMCID: PMC8225109 DOI: 10.3390/bios11060168] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 05/08/2021] [Accepted: 05/17/2021] [Indexed: 12/14/2022]
Abstract
Recent advancement has been accomplished in the field of biosensors through the modification of cellulose as a nano-engineered matrix material. To date, various techniques have been reported to develop cellulose-based matrices for fabricating different types of biosensors. Trends of involving cellulosic materials in paper-based multiplexing devices and microfluidic analytical technologies have increased because of their disposable, portable, biodegradable properties and cost-effectiveness. Cellulose also has potential in the development of cytosensors because of its various unique properties including biocompatibility. Such cellulose-based sensing devices are also being commercialized for various biomedical diagnostics in recent years and have also been considered as a method of choice in clinical laboratories and personalized diagnosis. In this paper, we have discussed the engineering aspects of cellulose-based sensors that have been reported where such matrices have been used to develop various analytical modules for the detection of small molecules, metal ions, macromolecules, and cells present in a diverse range of samples. Additionally, the developed cellulose-based biosensors and related analytical devices have been comprehensively described in tables with details of the sensing molecule, readout system, sensor configuration, response time, real sample, and their analytical performances.
Collapse
|
40
|
Recent advances in lab-on-paper diagnostic devices using blood samples. LAB ON A CHIP 2021; 21:1433-1453. [PMID: 33881033 DOI: 10.1039/d0lc01304h] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Lab-on-paper, or microfluidic paper-based analytical devices (μPADs), use paper as a substrate material, and are patterned with a system of microchannels, reaction zones and sensing elements to perform analysis and detection. The sample transfer in such devices is performed by capillary action. As a result, external driving forces are not required, and hence the size and cost of the device are significantly reduced. Lab-on-paper devices have thus attracted significant attention for point-of-care medical diagnostic purposes in recent years, particularly in less-developed regions of the world lacking medical resources and infrastructures. This review discusses the major advances in lab-on-paper technology for blood analysis and diagnosis in the past five years. The review focuses particularly on the many clinical applications of lab-on-paper devices, including diabetes diagnosis, acute myocardial infarction (AMI) detection, kidney function diagnosis, liver function diagnosis, cholesterol and triglyceride (TG) analysis, sickle-cell disease (SCD) and phenylketonuria (PKU) analysis, virus analysis, C-reactive protein (CRP) analysis, blood ion analysis, cancer factor analysis, and drug analysis. The review commences by introducing the basic transmission principles, fabrication methods, structural characteristics, detection techniques, and sample pretreatment process of modern lab-on-paper devices. A comprehensive review of the most recent applications of lab-on-paper devices to the diagnosis of common human diseases using blood samples is then presented. The review concludes with a brief summary of the main challenges and opportunities facing the lab-on-paper technology field in the coming years.
Collapse
|
41
|
Paper-based electrochemical peptide sensor for on-site detection of botulinum neurotoxin serotype A and C. Biosens Bioelectron 2021; 183:113210. [PMID: 33852978 DOI: 10.1016/j.bios.2021.113210] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 03/12/2021] [Accepted: 03/28/2021] [Indexed: 12/25/2022]
Abstract
Botulinum neurotoxins (BoNTs) produced by soil bacterium Clostridium botulinum are cause of botulism and listed as biohazard agents, thus rapid screening assays are needed for taking the correct countermeasures in a timely fashion. The gold standard method relies on the mouse lethality assay with a lengthy analysis time, i.e., 2-5 days, hindering the prompt management of food safety and medical diagnosis. Herein, we propose the first paper-based antibody-free sensor for reliable and rapid detection of BoNT/A and BoNT/C, exploiting their cleavage capability toward a synthetic peptide able to mimic the natural substrate SNAP-25. The peptide is labelled with the electroactive molecule methylene blue and immobilized on the paper-based electrode modified with gold nanoparticles. Because BoNT/A and BoNT/C can cleave the peptide with the removal of methylene blue from electrode surface, the presence of these neurotoxins in the sample leads to a signal decrease proportional to BoNT amount. The biosensor developed with the selected peptide and combined with smartphone assisted potentiostat is able to detect both BoNT/A and BoNT/C with a linearity up to 1 nM and a detection limit equal to 10 pM. The applicability of this biosensor was evaluated with spiked samples of orange juice, obtaining recovery values equal to 104 ± 6% and 98 ± 9% for 1 nM and 0.5 nM of BoNT/A, respectively.
Collapse
|
42
|
Recent trends in application of nanomaterials for the development of electrochemical microRNA biosensors. Mikrochim Acta 2021; 188:128. [PMID: 33740140 DOI: 10.1007/s00604-021-04784-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 03/10/2021] [Indexed: 01/10/2023]
Abstract
The biology of the late twentieth century was marked by the discovery in 1993 of a new class of small non-coding ribonucleic acids (RNAs) which play major roles in regulating the translation and degradation of messenger RNAs. These small RNAs (18-25 nucleotides), called microRNAs (miRNAs), are implied in several biological processes such as differentiation, metabolic homeostasis, or cellular apoptosis and proliferation. The discovery in 2008 that the presence of miRNAs in body fluids could be correlated with cancer (prostate, breast, colon, lung, etc.) or other diseases (diabetes, heart diseases, etc.) has made them new key players as biomarkers. Therefore, miRNA detection is of considerable significance in both disease diagnosis and in the study of miRNA function. Until these days, more than 1200 miRNAs have been identified. However, traditional methods developed for conventional DNA does not apply satisfactorily for miRNA, in particular due to the low expression level of these miRNA in biofluids, and because they are very short strands. Electrochemical biosensors can provide this sensitivity and also offer the advantages of mass fabrication, low-cost, and potential decentralized analysis, which has wide application for microRNAs sensing, with many promising results already reported. The present review summarizes some newly developed electrochemical miRNA detection methods.
Collapse
|
43
|
Flexible paper-based label-free electrochemical biosensor for the monitoring of miRNA-21 using core-shell Ag@Au/GQD nano-ink: a new platform for the accurate and rapid analysis by low cost lab-on-paper technology. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1286-1294. [PMID: 33624680 DOI: 10.1039/d1ay00142f] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
miRNA-21 is one of the most famous and prominent microRNAs that is important in the development and emergence of cancers. So, the sensitive and selective monitoring of miRNA-21 as a very common biomarker in cancer treatment is necessary. In this work, a novel paper-based electrochemical peptide nucleic acid (PNA) sensor was developed for the detection of miRNA-21 in human plasma samples by using Ag@Au core-shell nanoparticles electrodeposited on graphene quantum dots (GQD) conductive nano-ink (Ag@Au core-shell/GQD nano-ink), which was designed directly by writing pen-on paper technology on the surface of photographic paper. This nano-ink has a great surface area for biomarker immobilization. The prepared paper-based biosensor is very small and cheap, and also has high stability and sensitivity. Hybridization of PNA was measured using various electrochemical techniques, such as cyclic voltammetry (CV), square wave voltammetry (SWV) and chronoamperometry (ChA). FE-SEM (Field Scanning Electron Microscope), TEM (Transmission Electron Microscope), EDS and DLS (Dynamic Light Scattering) tests were performed to identify the engineering safety sensor. Under optimal conditions, the linear range for the calibration curve was from 5 pM to 5 μM, and the achieved LLOQ was 5 pM. The obtained results recommended that the proposed bioassay might be suitable for an early diagnosis of cancer based on the inhibition of the expression of miRNA-21, which activates the enzyme caspase and accelerates apoptotic proteins and death in tumor cells.
Collapse
|
44
|
|
45
|
Structural Insights on Tiny Peptide Nucleic Acid (PNA) Analogues of miRNA-34a: An in silico and Experimental Integrated Approach. Front Chem 2020; 8:568575. [PMID: 33330358 PMCID: PMC7719796 DOI: 10.3389/fchem.2020.568575] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 11/02/2020] [Indexed: 11/17/2022] Open
Abstract
In the present work, structural features of the interaction between peptide nucleic acid (PNA)-based analogs of the tumor-suppressor microRNA-34a with both its binding sites on MYCN mRNA were investigated. In particular, the region from base 1 to 8 ("seed" region) of miR-34a was reproduced in the form of an 8-mer PNA fragment (tiny PNA), and binding to target 3'UTR MYCN mRNA, was studied by a seldom reported and detailed NMR characterization, providing evidence for the formation of anti-parallel duplexes with a well-organized structural core. The formation of PNA-3'UTR duplexes was also confirmed by Circular Dichroism, and their melting curves were measured by UV spectroscopy. Nevertheless, this study offered a valuable comparison between molecular dynamics predictions and experimental evidence, which showed great correlation. Preliminary uptake assays were carried out in Neuroblastoma Kelly cells, using short peptide conjugates as carriers and FITC fluorescent tag for subcellular localization. Moderate internalization was observed without the use of transfecting agents. The reported results corroborate the interest toward the design and development of chimeric PNA/RNA sequences as effective RNA-targeting agents.
Collapse
|
46
|
Electrochemical Biosensors for Detection of MicroRNA as a Cancer Biomarker: Pros and Cons. BIOSENSORS 2020; 10:E186. [PMID: 33233700 PMCID: PMC7699780 DOI: 10.3390/bios10110186] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 11/16/2020] [Accepted: 11/18/2020] [Indexed: 12/23/2022]
Abstract
Cancer is the second most fatal disease in the world and an early diagnosis is important for a successful treatment. Thus, it is necessary to develop fast, sensitive, simple, and inexpensive analytical tools for cancer biomarker detection. MicroRNA (miRNA) is an RNA cancer biomarker where the expression level in body fluid is strongly correlated to cancer. Various biosensors involving the detection of miRNA for cancer diagnosis were developed. The present review offers a comprehensive overview of the recent developments in electrochemical biosensor for miRNA cancer marker detection from 2015 to 2020. The review focuses on the approaches to direct miRNA detection based on the electrochemical signal. It includes a RedOx-labeled probe with different designs, RedOx DNA-intercalating agents, various kinds of RedOx catalysts used to produce a signal response, and finally a free RedOx indicator. Furthermore, the advantages and drawbacks of these approaches are highlighted.
Collapse
|
47
|
Printed Electrochemical Biosensors: Opportunities and Metrological Challenges. BIOSENSORS 2020; 10:E166. [PMID: 33158129 PMCID: PMC7694196 DOI: 10.3390/bios10110166] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 10/30/2020] [Accepted: 11/02/2020] [Indexed: 12/14/2022]
Abstract
Printed electrochemical biosensors have recently gained increasing relevance in fields ranging from basic research to home-based point-of-care. Thus, they represent a unique opportunity to enable low-cost, fast, non-invasive and/or continuous monitoring of cells and biomolecules, exploiting their electrical properties. Printing technologies represent powerful tools to combine simpler and more customizable fabrication of biosensors with high resolution, miniaturization and integration with more complex microfluidic and electronics systems. The metrological aspects of those biosensors, such as sensitivity, repeatability and stability, represent very challenging aspects that are required for the assessment of the sensor itself. This review provides an overview of the opportunities of printed electrochemical biosensors in terms of transducing principles, metrological characteristics and the enlargement of the application field. A critical discussion on metrological challenges is then provided, deepening our understanding of the most promising trends in order to overcome them: printed nanostructures to improve the limit of detection, sensitivity and repeatability; printing strategies to improve organic biosensor integration in biological environments; emerging printing methods for non-conventional substrates; microfluidic dispensing to improve repeatability. Finally, an up-to-date analysis of the most recent examples of printed electrochemical biosensors for the main classes of target analytes (live cells, nucleic acids, proteins, metabolites and electrolytes) is reported.
Collapse
|
48
|
|
49
|
An electrochemical biosensor based on a graphene oxide modified pencil graphite electrode for direct detection and discrimination of double-stranded DNA sequences. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:4541-4550. [PMID: 32869790 DOI: 10.1039/d0ay01128b] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The ability to directly recognize double-stranded DNA (ds-DNA) is a major challenge in disease diagnosis and gene therapy because DNA is naturally double-stranded. Herein, a novel electrochemical biosensor for the sequence-specific recognition of ds-DNA using a peptide nucleic acid (PNA) probe and graphene oxide (GO) modified pencil graphite electrode is reported and applied for the direct detection of the desired sequence in plasmid samples. For this purpose, GO was assembled onto the pencil graphite electrode surface (GO/PGE) by a simple casting method and applied for PNA probe immobilization (PNA-GO/PGE). Upon addition of ds-DNA, the interaction of the PNA probe with ds-DNA induces probe detachment from the electrode surface which results in a guanine oxidation signal decrease. Under optimized conditions, the guanine oxidation signal decreased linearly with the ds-DNA concentration increasing in the range from 30 pM to 10 nM, with a detection limit of 1.3 pM. Moreover, the proposed biosensor was applied for the sensitive and selective detection of double-stranded target DNA in plasmid samples. This proposed method could be used as a platform for direct detection of various sequences in double-stranded genomic DNA.
Collapse
|