1
|
Chen S, Lan W, Yang D, Xu J, Hu Y, Lin H, Feng L. Self-powered photoelectrochemical sensor based on molecularly imprinted polymer-coupled CBFO photocathode and Ag 2S/SnS 2 photoanode for ultrasensitive dimethoate sensing. Anal Chim Acta 2025; 1337:343556. [PMID: 39800512 DOI: 10.1016/j.aca.2024.343556] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Accepted: 12/15/2024] [Indexed: 05/02/2025]
Abstract
Dimethoate (DIM) is one of the most extensively applied organophosphorus pesticides (OPs), which is used to boost farm productivity due to its high insecticidal efficacy. However, the excessive use of DIM can result in the extensive contamination of soil, groundwater and food. Monitoring of DIM in environmental and food samples is crucial in view of its potential health risks and environmental hazards from excessive residues. The expensive equipment and complex operations for current detection methods greatly limit their practical applications. Herein, a self-powered photoelectrochemical (PEC) sensing platform based on Ag2S/SnS2 photoanode, iron-doped cobalt borate (CBFO) photocathode, and molecularly imprinted polymers (MIPs) was proposed for the detection of DIM. The molecularly imprinted polymers at CBFO photocathode endow the self-powered PEC sensor with high selectivity. The Ag2S/SnS2 photoanode enhances the efficient of electron transfer between the photoanode and photocathode, contributing to the high sensitivity of PEC sensor. The self-powered molecularly imprinted PEC sensor exhibits outstanding sensitivity and selectivity for DIM at concentrations from 1 × 10-2 to 1 × 105 nM with a detection limit of 5.9 pM. Excellent recoveries (95.4 ± 2.6 %, 98.4 ± 2.3 %, 106.3 ± 3.3 %) were achieved in spiked crown pear samples, indicating that the molecularly imprinted PEC sensor is capable of detecting DIM in real samples. This research provides a novel simple, fast, highly selective and sensitive self-powered molecularly imprinted photoelectrochemical sensing platform for detection of DIM. The fabricated PEC sensor offers a promising candidate for the detection method of organophosphorus pesticides residues, which is of great significance for the fields of food safety and environmental protection.
Collapse
Affiliation(s)
- Shuqin Chen
- Key Laboratory of Chemical Materials and Green Nanotechnology, College of' Chemical Engineering and Materials Science, Quanzhou Normal University, Quanzhou, 362000, PR China
| | - Wanfu Lan
- College of Food Science, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, PR China
| | - Dapeng Yang
- Key Laboratory of Chemical Materials and Green Nanotechnology, College of' Chemical Engineering and Materials Science, Quanzhou Normal University, Quanzhou, 362000, PR China; School of Rehabilitation Science and Engineering, University of Health and Rehabilitation Sciences, Qingdao, Shandong, 266024, PR China.
| | - Jingying Xu
- Key Laboratory of Chemical Materials and Green Nanotechnology, College of' Chemical Engineering and Materials Science, Quanzhou Normal University, Quanzhou, 362000, PR China
| | - Yikun Hu
- Key Laboratory of Chemical Materials and Green Nanotechnology, College of' Chemical Engineering and Materials Science, Quanzhou Normal University, Quanzhou, 362000, PR China
| | - Hetong Lin
- College of Food Science, Fujian Agriculture and Forestry University, Fuzhou, Fujian, 350002, PR China.
| | - Liang Feng
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, PR China.
| |
Collapse
|
2
|
Shanmugam ST, Steijlen A, Laurijssen D, Campos R, Steckel J, Daems W, Bassini S, Daems E, De Wael K. A 96-Well LED Array for Multiplexed Photoelectrochemical Detection of Nucleic Acids. Anal Chem 2024. [PMID: 39264177 DOI: 10.1021/acs.analchem.4c01998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/13/2024]
Abstract
Photoelectrochemical detection of nucleic acid-based cancer biomarkers offers opportunities for highly sensitive, selective, and fast quantitative detection using low-cost measurement instruments. In order to establish itself as a standard method for identifying and quantifying nucleic acids, we have developed a multiplexing strategy using LED technology for photoelectrochemical detection in 96 samples simultaneously. A dedicated setup based on the 96-well plate configuration with a custom-made 96-well LED array was developed. Subsequently, a proof-of-concept study was performed for three miRNAs that are associated with prostate cancer, i.e., miRNA-141, miRNA-145, and miRNA-375. First, measurements with photosensitizer chlorin e6 and redox reporter hydroquinone free in solution proved the proper functioning of the multiplexed detection. Second, the photoelectrochemical detection of the three miRNAs at 24 nM levels was successfully demonstrated. Thereafter, linear calibration curves (R2 > 0.9 for all analytes) were made with plasma spiked with 8-500 pM miRNA. This work presents the first system for multiplexed high-throughput photoelectrochemical detection, allowing it potentially to become a cost-effective and faster alternative to RT-qPCR and gene sequencing techniques in the future.
Collapse
Affiliation(s)
- Saranya Thiruvottriyur Shanmugam
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| | - Annemarijn Steijlen
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| | - Dennis Laurijssen
- Cosys-Lab, Faculty of Applied Engineering, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| | - Rui Campos
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| | - Jan Steckel
- Cosys-Lab, Faculty of Applied Engineering, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| | - Walter Daems
- Cosys-Lab, Faculty of Applied Engineering, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| | - Simone Bassini
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| | - Elise Daems
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| | - Karolien De Wael
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, Antwerp 2020, Belgium
| |
Collapse
|
3
|
Shanmugam ST, Campos R, Trashin S, Daems E, Carneiro D, Fraga A, Ribeiro R, De Wael K. Singlet oxygen-based photoelectrochemical detection of miRNAs in prostate cancer patients' plasma: A novel diagnostic tool for liquid biopsy. Bioelectrochemistry 2024; 158:108698. [PMID: 38640856 DOI: 10.1016/j.bioelechem.2024.108698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 03/08/2024] [Accepted: 03/27/2024] [Indexed: 04/21/2024]
Abstract
Dysregulation of miRNA expression occurs in many cancers, making miRNAs useful in cancer diagnosis and therapeutic guidance. In a clinical context using methods such as polymerase chain reaction (PCR), the limited amount of miRNAs in circulation often limits their quantification. Here, we present a PCR-free and sensitive singlet oxygen (1O2)-based strategy for the detection and quantification of miRNAs in untreated human plasma from patients diagnosed with prostate cancer. A target miRNA is specifically captured by functionalised magnetic beads and a detection oligonucleotide probe in a sandwich-like format. The formed complex is concentrated at the sensor surface via magnetic beads, providing an interface for the photoinduced redox signal amplification. The detection oligonucleotide probe bears a molecular photosensitiser, which produces 1O2 upon illumination, oxidising a redox reporter and creating a redox cycling loop, allowing quantification of pM level miRNA in diluted human plasma within minutes after hybridisation and without target amplification.
Collapse
Affiliation(s)
- Saranya Thiruvottriyur Shanmugam
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Rui Campos
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Stanislav Trashin
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Elise Daems
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Diogo Carneiro
- i3S, Tumour & Microenvironment Interactions Group, Instituto de Investigação e Inovação em Saúde, University of Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; Department of Urology, Centro Hospitalar Universitário do Porto, Largo Prof. Abel Salazar, 4099-001 Porto, Portugal
| | - Avelino Fraga
- i3S, Tumour & Microenvironment Interactions Group, Instituto de Investigação e Inovação em Saúde, University of Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; Department of Urology, Centro Hospitalar Universitário do Porto, Largo Prof. Abel Salazar, 4099-001 Porto, Portugal
| | - Ricardo Ribeiro
- i3S, Tumour & Microenvironment Interactions Group, Instituto de Investigação e Inovação em Saúde, University of Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; Department of Pathology, Centro Hospitalar Universitário do Porto, Largo Prof. Abel Salazar, 4099-001 Porto, Portugal
| | - Karolien De Wael
- A-Sense Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
| |
Collapse
|