1
|
Jia Y, Han S, Li B, Liu C, Ta D. Backscatter measurement of cancellous bone using the ultrasound transit time spectroscopy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2670-2686. [PMID: 38639562 DOI: 10.1121/10.0025689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 03/26/2024] [Indexed: 04/20/2024]
Abstract
Recently, ultrasound transit time spectroscopy (UTTS) was proposed as a promising method for bone quantitative ultrasound measurement. Studies have showed that UTTS could estimate the bone volume fraction and other trabecular bone structure in ultrasonic through-transmission measurements. The goal of this study was to explore the feasibility of UTTS to be adapted in ultrasonic backscatter measurement and further evaluate the performance of backscattered ultrasound transit time spectrum (BS-UTTS) in the measurement of cancellous bone density and structure. First, taking ultrasonic attenuation into account, the concept of BS-UTTS was verified on ultrasonic backscatter signals simulated from a set of scatterers with different positions and intensities. Then, in vitro backscatter measurements were performed on 26 bovine cancellous bone specimens. After a logarithmic compression of the BS-UTTS, a linear fitting of the log-compressed BS-UTTS versus ultrasonic propagated distance was performed and the slope and intercept of the fitted line for BS-UTTS were determined. The associations between BS-UTTS parameters and cancellous bone features were analyzed using simple linear regression. The results showed that the BS-UTTS could make an accurate deconvolution of the backscatter signal and predict the position and intensity of the simulated scatterers eliminating phase interference, even the simulated backscatter signal was with a relatively low signal-to-noise ratio. With varied positions and intensities of the scatterers, the slope of the fitted line for the log-compressed BS-UTTS versus ultrasonic propagated distance (i.e., slope of BS-UTTS for short) yield a high agreement (r2 = 99.84%-99.96%) with ultrasonic attenuation in simulated backscatter signal. Compared with the high-density cancellous bone, the low-density specimen showed more abundant backscatter impulse response in the BS-UTTS. The slope of BS-UTTS yield a significant correlation with bone mineral density (r = 0.87; p < 0.001), BV/TV (r = 0.87; p < 0.001), and cancellous bone microstructures (r up to 0.87; p < 0.05). The intercept of BS-UTTS was also significantly correlated with bone densities (r = -0.87; p < 0.001) and trabecular structures (|r|=0.43-0.80; p < 0.05). However, the slope of the BS-UTTS underestimated attenuation when measurements were performed experimentally. In addition, a significant non-linear relationship was observed between the measured attenuation and the attenuation estimated by the slope of the BS-UTTS. This study demonstrated that the UTTS method could be adapted to ultrasonic backscatter measurement of cancellous bone. The derived slope and intercept of BS-UTTS could be used in the measurement of bone density and microstructure. The backscattered ultrasound transit time spectroscopy might have potential in the diagnosis of osteoporosis in the clinic.
Collapse
Affiliation(s)
- Yan Jia
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Shuai Han
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Boyi Li
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Chengcheng Liu
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
| | - Dean Ta
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
- Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China
| |
Collapse
|
2
|
Bi D, Shi L, Li B, Li Y, Liu C, Le LH, Luo J, Wang S, Ta D. The Protocol of Ultrasonic Backscatter Measurements of Musculoskeletal Properties. PHENOMICS (CHAM, SWITZERLAND) 2024; 4:72-80. [PMID: 38605911 PMCID: PMC11004104 DOI: 10.1007/s43657-023-00122-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 07/15/2023] [Accepted: 07/19/2023] [Indexed: 04/13/2024]
Abstract
This study aims to introduce the protocol for ultrasonic backscatter measurements of musculoskeletal properties based on a novel ultrasonic backscatter bone diagnostic (UBBD) instrument. Dual-energy X-ray absorptiometry (DXA) can be adopted to measure bone mineral density (BMD) in the hip, spine, legs and the whole body. The muscle and fat mass in the legs and the whole body can be also calculated by DXA body composition analysis. Based on the proposed protocol for backscatter measurements by UBBD, ultrasonic backscatter signals can be measured in vivo, deriving three backscatter parameters [apparent integral backscatter (AIB), backscatter signal peak amplitude (BSPA) and the corresponding arrival time (BSPT)]. AIB may provide important diagnostic information about bone properties. BSPA and BSPT may be important indicators of muscle and fat properties. The standardized backscatter measurement protocol of the UBBD instrument may have the potential to evaluate musculoskeletal characteristics, providing help for promoting the application of the backscatter technique in the clinical diagnosis of musculoskeletal disorders (MSDs), such as osteoporosis and muscular atrophy.
Collapse
Affiliation(s)
- Dongsheng Bi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 2005 Songhu Road, Yangpu District, Shanghai, 200438 China
| | - Lingwei Shi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 2005 Songhu Road, Yangpu District, Shanghai, 200438 China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, Shanghai, 200433 China
| | - Ying Li
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 2005 Songhu Road, Yangpu District, Shanghai, 200438 China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai, 200433 China
| | - Lawrence H. Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, T6G2B7 Canada
| | - Jingchun Luo
- Human Phenome Institute, Fudan University, Shanghai, 201203 China
| | - Sijia Wang
- Shanghai Institute of Nutrition and Health, Chinese Academy of Sciences, Shanghai, 200031 China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 2005 Songhu Road, Yangpu District, Shanghai, 200438 China
- Academy for Engineering and Technology, Fudan University, Shanghai, 200433 China
- Human Phenome Institute, Fudan University, Shanghai, 201203 China
| |
Collapse
|
3
|
Kovács K, Váncsa S, Agócs G, Harnos A, Hegyi P, Weninger V, Baross K, Kovács B, Soós G, Kocsis G. Anisotropy, Anatomical Region, and Additional Variables Influence Young's Modulus of Bone: A Systematic Review and Meta-Analysis. JBMR Plus 2023; 7:e10835. [PMID: 38130752 PMCID: PMC10731124 DOI: 10.1002/jbm4.10835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 08/09/2023] [Accepted: 09/25/2023] [Indexed: 12/23/2023] Open
Abstract
The importance of finite element analysis (FEA) is growing in orthopedic research, especially in implant design. However, Young's modulus (E) values, one of the most fundamental parameters, can range across a wide scale. Therefore, our study aimed to identify factors influencing E values in human bone specimens. We report our systematic review and meta-analysis based on the recommendation of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guideline. We conducted the analysis on November 21, 2021. We included studies investigating healthy human bone specimens and reported on E values regarding demographic data, specimen characteristics, and measurement specifics. In addition, we included study types reporting individual specimen measurements. From the acquired data, we created a cohort in which we performed an exploratory data analysis that included the explanatory variables selected by random forest and regression trees methods, and the comparison of groups using independent samples Welch's t test. A total of 756 entries were included from 48 articles. Eleven different bones of the human body were included in these articles. The range of E values is between 0.008 and 33.7 GPa. The E values were most heavily influenced by the cortical or cancellous type of bone tested. Measuring method (compression, tension, bending, and nanoindentation), the anatomical region within a bone, the position of the bone within the skeleton, and the bone specimen size had a decreasing impact on the E values. Bone anisotropy, specimen condition, patient age, and sex were selected as important variables considering the value of E. On the basis of our results, E values of a bone change with bone characteristics, measurement techniques, and demographic variables. Therefore, the evaluation of FEA should be performed after the standardization of in vitro measurement protocol. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Krisztián Kovács
- Department of OrthopaedicsSemmelweis UniversityBudapestHungary
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - Szilárd Váncsa
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
- Institute for Translational Medicine, Szentágothai Research Centre, Medical SchoolUniversity of PécsPécsHungary
- Division of Pancreatic Diseases, Heart and Vascular CenterSemmelweis UniversityBudapestHungary
| | - Gergely Agócs
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
- Department of Biophysics and Radiation BiologySemmelweis UniversityBudapestHungary
| | - Andrea Harnos
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
- Department of BiostatisticsUniversity of Veterinary MedicineBudapestHungary
| | - Péter Hegyi
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
- Institute for Translational Medicine, Szentágothai Research Centre, Medical SchoolUniversity of PécsPécsHungary
- Division of Pancreatic Diseases, Heart and Vascular CenterSemmelweis UniversityBudapestHungary
| | - Viktor Weninger
- Department of OrthopaedicsSemmelweis UniversityBudapestHungary
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - Katinka Baross
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - Bence Kovács
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - Gergely Soós
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - György Kocsis
- Department of OrthopaedicsSemmelweis UniversityBudapestHungary
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| |
Collapse
|
4
|
Sadoughi S, Bevill G, Morgan EF, Palepu V, Keaveny TM, Wear KA. Biomechanical structure-function relations for human trabecular bone - comparison of calcaneus, femoral neck, greater trochanter, proximal tibia, and vertebra. Comput Methods Biomech Biomed Engin 2023; 26:508-516. [PMID: 35579530 PMCID: PMC9669279 DOI: 10.1080/10255842.2022.2069465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 04/04/2022] [Accepted: 04/20/2022] [Indexed: 11/03/2022]
Abstract
MicroCT-based finite element models were used to compute power law relations for uniaxial compressive yield stress versus bone volume fraction for 78 cores of human trabecular bone from five anatomic sites. The leading coefficient of the power law for calcaneus differed from those for most of the other sites (p < 0.05). However, after normalizing by site-specific mean values, neither the leading coefficient (p > 0.5) nor exponent (p > 0.5) differed among sites, suggesting that a given percentage deviation from mean bone volume fraction has the same mechanical consequence for all sites investigated. These findings help explain the success of calcaneal x-ray and ultrasound measurements for predicting hip fracture risk.
Collapse
Affiliation(s)
- Saghi Sadoughi
- Department of Mechanical Engineering, University of California, Berkeley, CA
| | - Grant Bevill
- Mechanical Engineering Department, University of North Florida, Jacksonville, FL
| | - Elise F Morgan
- Departments of Mechanical Engineering and Biomedical Engineering, Boston University, Boston, MA
| | - Vivek Palepu
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| | - Tony M Keaveny
- Department of Mechanical Engineering, University of California, Berkeley, CA
- Department of Bioengineering, University of California, Berkeley, CA
| | - Keith A Wear
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| |
Collapse
|
5
|
Alomari A, Langton C. Comparison of deconvoluted-convoluted reconstituted ultrasound signals with their experimental original in a porous composite, cancellous bone. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2023. [DOI: 10.1016/j.jrras.2022.100519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
6
|
Strässle M, Grossmann J, Eppenberger P, Faas A, Jerkovic I, Floris J, Öhrström L, Akgül G, Aldakak L, Rühli F, Bender N, Staub K. Short-termed changes in quantitative ultrasound estimated bone density among young men in an 18-weeks follow-up during their basic training for the Swiss Armed Forces. PeerJ 2023; 11:e15205. [PMID: 37041974 PMCID: PMC10083003 DOI: 10.7717/peerj.15205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 03/19/2023] [Indexed: 04/13/2023] Open
Abstract
Background Quantitative Ultrasound (QUS) methods have been widely used to assess estimated bone density. This study aimed to assess changes in estimated bone density in association with changes in body composition, physical activity, and anthropometry. Methods We examined changes in anthropometry, body composition, and physical activity associated with changes in estimated bone mineral density (measured using quantitative ultrasound with a heel ultrasound device indicating broadband ultrasound attenuation BUA and speed of sound SOS) in a follow-up sample of n = 73 young men at the beginning and again 18 weeks later at the end of basic military training. Results At the end of the basic training, the subjects were on average significantly heavier (+1.0%), slightly taller (+0.5%) and had a higher fat mass (+6.6%) and grip strength (+8.6%). A significant decrease in mean physical activity (-49.5%) and mean estimated bone density calculated with BUA (-7.5%) was observed in the paired t-test. The results of the multivariable linear regressions (backward selection) show that changes in skeletal muscle mass (delta = 2nd measurement minus 1st measurement) have negative and body weight (delta) have positive association with the speed of sound SOS (delta), while fat mass (delta) and physical activity (delta) had the strongest negative associations with estimated bone mineral density (delta). In particular, we found a negative association between fat mass (delta) and estimated bone mineral density (delta, estimated with BUA). Conclusion Our study suggests that estimated bone density from the calcaneus can change within a few months even in young and mostly healthy individuals, depending upon physical activity levels and other co-factors. Further studies including other troop types as control groups as well as on women should follow in order to investigate this public health relevant topic in more depth. To what extent the estimated bone density measurement with quantitative ultrasound is clinically relevant needs to be investigated in further studies.
Collapse
Affiliation(s)
- Michael Strässle
- Kantonsspital St. Gallen, St. Gallen, Switzerland
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
- Medical Faculty, University of Zürich, Zurich, Switzerland
| | - Jonas Grossmann
- Functional Genomics Center Zurich, Eidgenössische Technische Hochschule Zürich, Zürich, Switzerland
- SIB Swiss Institute of Bioinformatics, Lausanne, Switzerland
| | - Patrick Eppenberger
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
| | | | | | - Joël Floris
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
| | - Lena Öhrström
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
| | - Gülfirde Akgül
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
| | - Lafi Aldakak
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
| | - Frank Rühli
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
- Center for Integrative Human Physiology (ZIHP), University of Zurich, Zurich, Switzerland
| | - Nicole Bender
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
| | - Kaspar Staub
- Institute of Evolutionary Medicine, University of Zurich, Zurich, Switzerland
- Center for Integrative Human Physiology (ZIHP), University of Zurich, Zurich, Switzerland
| |
Collapse
|
7
|
Bi D, Shi L, Liu C, Li B, Li Y, Le LH, Luo J, Wang S, Ta D. Ultrasonic Through-Transmission Measurements of Human Musculoskeletal and Fat Properties. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:347-355. [PMID: 36266143 DOI: 10.1016/j.ultrasmedbio.2022.09.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 09/07/2022] [Accepted: 09/09/2022] [Indexed: 06/16/2023]
Abstract
The study described here was aimed at investigating the feasibility of using the ultrasonic through-transmission technique to estimate human musculoskeletal and fat properties. Five hundred eighty-two volunteers were assessed by dual-energy X-ray absorptiometry (DXA) and ultrasonic transmission techniques. Bone mineral density (BMD), muscle and fat mass were measured for both legs and the whole body. Hip BMD and spine BMD were also measured. Ultrasonic transmission measurements were performed on the heel, and the measured parameters were broadband ultrasound attenuation (BUA), speed of sound (SOS), ultrasonic stiffness index (SI), T-score and Z-score, which were significantly correlated with all measured BMDs. The optimal correlation was observed between SI and left-leg BMD (p < 0.001) before and after adjustment for age, sex and body mass index (BMI). The linear and partial correlation analyses revealed that BUA and SOS were closely associated with muscle and fat mass, respectively. Multiple regressions revealed that muscle and fat mass significantly contributed to the prediction of transmission parameters, explaining up to 17.83% (p < 0.001) variance independently of BMD. The results suggest that the ultrasonic through-transmission technique could help in the clinical diagnosis of skeletal and muscular system diseases.
Collapse
Affiliation(s)
- Dongsheng Bi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Lingwei Shi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Ying Li
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| | - Jingchun Luo
- Human Phenome Institute, Fudan University, Shanghai, China
| | - Sijia Wang
- Shanghai Institute of Nutrition and Health, Chinese Academy of Sciences, Shanghai, China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China; Academy for Engineering and Technology, Fudan University, Shanghai, China; Human Phenome Institute, Fudan University, Shanghai, China.
| |
Collapse
|
8
|
Patel H, Woods L, Teesdale-Spittle P, Dennison E. A cross-sectional study of the relationship between recreational sporting activity and calcaneal bone density in adolescents and young adults. PHYSICIAN SPORTSMED 2022; 50:218-226. [PMID: 33724899 DOI: 10.1080/00913847.2021.1903819] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Childhood and adolescence are critical periods of bone development. Sporting activity is thought to impact peak bone mass acquisition, but most studies have used dual-energy X-ray absorptiometry (DXA) to assess bone health and reported associations between bone mass and elite sporting activity. The objective of this study was instead to assess the relationship between recreational sporting activity (RSA) and another bone assessment, calcaneal quantitative ultrasound (cQUS), in adolescents and young adults. METHODS We related recreational sporting activity, assessed through a lifestyle questionnaire, to heel ultrasound bone parameters in a cohort of New Zealand students aged 16-35 years. Complete datasets with data on all relevant confounders (body mass index (BMI), pubertal timing, smoking status, and alcohol consumption) were available for 452 participants. cQUS was performed using a Lunar Achilles EX II machine to obtain bone parameters, broadband ultrasound attenuation (BUA), and speed of sound (SOS); stiffness index (SI) was derived from these measures. All descriptive statistics and statistical analyses were carried out using SPSS Statistics for Macintosh, Version 23.0 (IBM Corp., Armonk, NY, USA). Results are presented as p-values and 95% CI. RESULTS Reported lifetime sport participation declined after an individual's mid-teens. Bone cQUS parameters (SI and BUA and T-score) were all positively associated with BMI, and current physical activity (SI, SOS, BUA, T-score, and Z-score) with SI and SOS measures most strongly associated with current high impact and past recreational sporting activity (all p < 0.05). CONCLUSION Calcaneal heel ultrasound bone parameters were associated with physical activity, with SI and SOS rather than BUA more strongly related to current and past recreational sporting activity in young New Zealand adults.
Collapse
Affiliation(s)
- Hansa Patel
- School of Biological Sciences, Victoria University of Wellington, New Zealand
| | - Lisa Woods
- School of Biological Sciences, Victoria University of Wellington, New Zealand
| | | | - Elaine Dennison
- School of Biological Sciences, Victoria University of Wellington, New Zealand.,School of Biological Sciences, Victoria University of Wellington, New Zealand & MRC Lifecourse Epidemiology Unit, Southampton, UK
| |
Collapse
|
9
|
Wang F, Metzner F, Osterhoff G, Schleifenbaum S. Assessment of the efficiency of different chemical treatments and ultrasonic cleaning for defatting of cancellous bone samples. Cell Tissue Bank 2021; 23:499-510. [PMID: 34714441 PMCID: PMC9372121 DOI: 10.1007/s10561-021-09969-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 09/30/2021] [Indexed: 11/26/2022]
Abstract
Our study aimed to asses the defatting efficiency of different methods, which are commonly used and easily available in the laboratory in order to find a method that is effective, convenient, safe, and economical. Cylindrical cancellous bone specimens were obtained from fresh-frozen human cadaver femoral condyles, cut into multiple small specimens (Ø8 × 2 mm), and assigned to two groups that were treated with either chemical solvent soaking (Solvent group) or ultrasonic cleaning (Ultrasound group). Each group was divided into several subgroups based on different treatments. Digital photographs were taken of each specimen. The difference of material density (Δρb), apparent density (Δρapp), and porosity (ΔP) before and after treatment were used as evaluation indicators. For the solvent group, in Δρb, only the combination of 99% ethanol and detergent solution showed a significant difference before and after treatment (P = 0.00). There was no significant difference in ΔP among acetone, the mixture of 99% ethanol and acetone, and the combination of 99% ethanol and detergent solution (P = 0.93). For the ultrasound group, the median of all subgroups in Δρapp and ΔP were all lower than the solvent group. The combination of 99% ethanol and detergent solution (v/v = 1:20), as well as the mixture of 99% ethanol and acetone (v/v = 1:1), seem to be the optimal defatting methods for 2 mm thick cancellous bone slices due to their effectiveness, availability, low-cost and safety. Chemical soaking for 24 h is more effective than ultrasonic cleaning with 99% ethanol or acetone for 20 or 40 min.
Collapse
Affiliation(s)
- Fangxing Wang
- ZESBO - Center for Research on Musculoskeletal Systems, Department of Orthopaedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.
- Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Liebigstraße. 20 Haus 4, 04103, Leipzig, Germany.
| | - Florian Metzner
- ZESBO - Center for Research on Musculoskeletal Systems, Department of Orthopaedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany
| | - Georg Osterhoff
- Department of Orthopedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Liebigstraße. 20 Haus 4, 04103, Leipzig, Germany
| | - Stefan Schleifenbaum
- ZESBO - Center for Research on Musculoskeletal Systems, Department of Orthopaedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany
| |
Collapse
|
10
|
Bi D, Dai Z, Liu D, Wu F, Liu C, Li Y, Li B, Li Z, Li Y, Ta D. Ultrasonic Backscatter Measurements of Human Cortical and Trabecular Bone Densities in a Head-Down Bed-Rest Study. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2404-2415. [PMID: 34052063 DOI: 10.1016/j.ultrasmedbio.2021.04.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 03/24/2021] [Accepted: 04/02/2021] [Indexed: 06/12/2023]
Abstract
This study aims to investigate the feasibility of quantitative ultrasonic backscatter in evaluating human cortical and trabecular bone densities in vivo based on a head-down-tilt bed rest study, with 36 participants tested through 90 d of bed rest and 180 d of recovery. Backscatter measurements were performed using an ultrasonic backscatter bone diagnostic instrument. Backscatter parameters were calculated with a dynamic signal-of-interest method, which was proposed to ensure the same ultrasonic interrogated volume in cortical and trabecular bones. The backscatter parameters exhibited significant correlations with site-matched bone densities provided by high-resolution peripheral quantitative computed tomography (0.33 < |R| < 0.72, p < 0.05). Some bone densities and backscatter parameters exhibited significant changes after the 90-d bed rest. The proposed method can be used to characterize bone densities, and the portable ultrasonic backscatter bone diagnostic device might be used to non-invasively reveal mean bone loss (across a group of people) after long-term bed rest and microgravity conditions of spaceflight missions.
Collapse
Affiliation(s)
- Dongsheng Bi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Zhongquan Dai
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Duwei Liu
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Feng Wu
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Ying Li
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Zhili Li
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Yinghui Li
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China; Academy for Engineering and Technology, Fudan University, Shanghai, China.
| |
Collapse
|
11
|
Wear KA. Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:454-482. [PMID: 31634127 PMCID: PMC7050438 DOI: 10.1109/tuffc.2019.2947755] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Ultrasound is now a clinically accepted modality in the management of osteoporosis. The most common commercial clinical devices assess fracture risk from measurements of attenuation and sound speed in cancellous bone. This review discusses fundamental mechanisms underlying the interaction between ultrasound and cancellous bone. Because of its two-phase structure (mineralized trabecular network embedded in soft tissue-marrow), its anisotropy, and its inhomogeneity, cancellous bone is more difficult to characterize than most soft tissues. Experimental data for the dependencies of attenuation, sound speed, dispersion, and scattering on ultrasound frequency, bone mineral density, composition, microstructure, and mechanical properties are presented. The relative roles of absorption, scattering, and phase cancellation in determining attenuation measurements in vitro and in vivo are delineated. Common speed of sound metrics, which entail measurements of transit times of pulse leading edges (to avoid multipath interference), are greatly influenced by attenuation, dispersion, and system properties, including center frequency and bandwidth. However, a theoretical model has been shown to be effective for correction for these confounding factors in vitro and in vivo. Theoretical and phantom models are presented to elucidate why cancellous bone exhibits negative dispersion, unlike soft tissue, which exhibits positive dispersion. Signal processing methods are presented for separating "fast" and "slow" waves (predicted by poroelasticity theory and supported in cancellous bone) even when the two waves overlap in time and frequency domains. Models to explain dependencies of scattering on frequency and mean trabecular thickness are presented and compared with measurements. Anisotropy, the effect of the fluid filler medium (marrow in vivo or water in vitro), phantoms, computational modeling of ultrasound propagation, acoustic microscopy, and nonlinear properties in cancellous bone are also discussed.
Collapse
|
12
|
Li Y, Li B, Li Y, Liu C, Xu F, Zhang R, Ta D, Wang W. The Ability of Ultrasonic Backscatter Parametric Imaging to Characterize Bovine Trabecular Bone. ULTRASONIC IMAGING 2019; 41:271-289. [PMID: 31307317 DOI: 10.1177/0161734619862190] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The ultrasonic backscatter technique holds the promise of characterizing bone density and microstructure. This paper conducts ultrasonic backscatter parametric imaging based on measurements of apparent integrated backscatter (AIB), spectral centroid shift (SCS), frequency slope of apparent backscatter (FSAB), and frequency intercept of apparent backscatter (FIAB) for representing trabecular bone mass and microstructure. We scanned 33 bovine trabecular bone samples using a 7.5 MHz focused transducer in a 20 mm × 20 mm region of interest (ROI) with a step interval of 0.05 mm. Images based on the ultrasonic backscatter parameters (i.e., AIB, SCS, FSAB, and FIAB) were constructed to compare with photographic images of the specimens as well as two-dimensional (2D) μ-CT images from approximately the same depth and location of the specimen. Similar structures and trabecular alignments can be observed among these images. Statistical analyses demonstrated that the means and standard deviations of the ultrasonic backscatter parameters exhibited significant correlations with bone density (|R| = 0.45-0.78, p < 0.01) and bone microstructure (|R| = 0.44-0.87, p < 0.001). Some bovine trabecular bone microstructure parameters were independently associated with the ultrasonic backscatter parameters (ΔR2 = 4.18%-44.45%, p < 0.05) after adjustment for bone apparent density (BAD). The results show that ultrasonic backscatter parametric imaging can provide a direct view of the trabecular microstructure and can reflect information about the density and microstructure of trabecular bone.
Collapse
Affiliation(s)
- Ying Li
- 1 Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Boyi Li
- 1 Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Yifang Li
- 1 Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Chengcheng Liu
- 2 Institute of Acoustics, Tongji University, Shanghai, China
| | - Feng Xu
- 1 Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Rong Zhang
- 3 Department of Neonatology, Children's Hospital of Fudan University, Shanghai, China
| | - Dean Ta
- 1 Department of Electronic Engineering, Fudan University, Shanghai, China
- 4 Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention (MICCAI) of Shanghai, Shanghai, China
- 5 Human Phenome Institute, Fudan University, Shanghai, China
| | - Weiqi Wang
- 1 Department of Electronic Engineering, Fudan University, Shanghai, China
| |
Collapse
|
13
|
Yue Y, Yang H, Li Y, Zhong H, Tang Q, Wang J, Wang R, He H, Chen W, Chen D. Combining ultrasonic and computed tomography scanning to characterize mechanical properties of cancellous bone in necrotic human femoral heads. Med Eng Phys 2019; 66:12-17. [DOI: 10.1016/j.medengphy.2019.02.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 01/30/2019] [Accepted: 02/01/2019] [Indexed: 10/27/2022]
|
14
|
Maimbourg G, Houdouin A, Deffieux T, Tanter M, Aubry JF. Steering Capabilities of an Acoustic Lens for Transcranial Therapy: Numerical and Experimental Studies. IEEE Trans Biomed Eng 2019; 67:27-37. [PMID: 30932823 DOI: 10.1109/tbme.2019.2907556] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
For successful brain therapy, transcranial focused ultrasound must compensate for the time shifts induced locally by the skull. The patient-specific phase profile is currently generated by multi-element arrays which, over time, have tended toward increasing element count. We recently introduced a new approach, consisting of a single-element transducer coupled to an acoustic lens of controlled thickness. By adjusting the local thickness of the lens, we were able to induce phase differences which compensated those induced by the skull. Nevertheless, such an approach suffers from an apparent limitation: the lens is a priori designed for one specific target. In this paper, we demonstrate the possibility of taking advantage of the isoplanatic angle of the aberrating skull in order to steer the focus by mechanically moving the transducer/acoustic lens pair around its initial focusing position. This study, conducted on three human skull samples, demonstrates that tilting of the transducer with the lens restores a single -3 dB focal volume at 914 kHz for a steering up to ±11 mm in the transverse direction, and ±10 mm in the longitudinal direction, around the initial focal region.
Collapse
|
15
|
Liu C, Li B, Diwu Q, Li Y, Zhang R, Ta D, Wang W. Relationships of Ultrasonic Backscatter With Bone Densities and Microstructure in Bovine Cancellous Bone. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2311-2321. [PMID: 30575524 DOI: 10.1109/tuffc.2018.2872084] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This study was designed to investigate the associations among ultrasonic backscatter, bone densities, and microstructure in bovine cancellous bone. Ultrasonic backscatter measurements were performed on 33 bovine cancellous bone specimens with a 2.25-MHz transducer. Ultrasonic apparent backscatter parameters ("apparent" means not compensating for ultrasonic attenuation and diffraction) were calculated with optimal signals of interest. The results showed that ultrasonic backscatter was significantly related to bone densities and microstructure ( R2 = 0.17 -0.88 and ). After adjusting the correlations by bone mineral density (BMD), the bone apparent density (BAD) and some trabecular structural features still contributed significantly to the adjusted correlations, with moderate additional variance explained ( ∆R2 = 9.7 % at best). Multiple linear regressions revealed that both BAD and trabecular structure contributed significantly and independently to the prediction of ultrasound backscatter (adjusted R2 = 0.75 -0.89 and ), explaining an additional 14% of the variance at most, compared with that of BMD measurements alone. The results proved that ultrasonic backscatter was primarily determined by BAD, not BMD, but the combination of bone structure and densities could achieve encouragingly better performances (89% of the variance explained at best) in predicting backscatter properties. This study demonstrated that ultrasonic apparent backscatter might provide additional density and structural features unrelated to current BMD measurement. Therefore, we suggest that ultrasonic backscatter measurement could play a more important role in cancellous bone evaluation.
Collapse
|
16
|
Lee KI. Velocity dispersion and backscatter in marrow-filled and water-filled trabecular bone samples in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:EL386. [PMID: 30522272 DOI: 10.1121/1.5077019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 10/22/2018] [Indexed: 06/09/2023]
Abstract
The phase velocity and the backscatter coefficient were measured in 28 bovine femoral trabecular bone samples filled with marrow and water in vitro from 0.2 to 0.6 MHz. The phase velocities decreased approximately linearly with increasing frequency and the average dispersion rate of -34 ms-1 MHz-1 in the marrow-filled samples was higher than that of -42 ms-1 MHz-1 in the water-filled samples. The backscatter coefficients exhibited nonlinear, monotonically increasing dependences on the frequency and the average value of the exponent n = 2.92 (frequency dependence) in the marrow-filled samples was higher than the value of n = 2.79 in the water-filled samples.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 24341, Republic of Korea
| |
Collapse
|
17
|
Morrison TM, Pathmanathan P, Adwan M, Margerrison E. Advancing Regulatory Science With Computational Modeling for Medical Devices at the FDA's Office of Science and Engineering Laboratories. Front Med (Lausanne) 2018; 5:241. [PMID: 30356350 PMCID: PMC6167449 DOI: 10.3389/fmed.2018.00241] [Citation(s) in RCA: 70] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 08/08/2018] [Indexed: 12/29/2022] Open
Abstract
Protecting and promoting public health is the mission of the U.S. Food and Drug Administration (FDA). FDA's Center for Devices and Radiological Health (CDRH), which regulates medical devices marketed in the U.S., envisions itself as the world's leader in medical device innovation and regulatory science-the development of new methods, standards, and approaches to assess the safety, efficacy, quality, and performance of medical devices. Traditionally, bench testing, animal studies, and clinical trials have been the main sources of evidence for getting medical devices on the market in the U.S. In recent years, however, computational modeling has become an increasingly powerful tool for evaluating medical devices, complementing bench, animal and clinical methods. Moreover, computational modeling methods are increasingly being used within software platforms, serving as clinical decision support tools, and are being embedded in medical devices. Because of its reach and huge potential, computational modeling has been identified as a priority by CDRH, and indeed by FDA's leadership. Therefore, the Office of Science and Engineering Laboratories (OSEL)-the research arm of CDRH-has committed significant resources to transforming computational modeling from a valuable scientific tool to a valuable regulatory tool, and developing mechanisms to rely more on digital evidence in place of other evidence. This article introduces the role of computational modeling for medical devices, describes OSEL's ongoing research, and overviews how evidence from computational modeling (i.e., digital evidence) has been used in regulatory submissions by industry to CDRH in recent years. It concludes by discussing the potential future role for computational modeling and digital evidence in medical devices.
Collapse
Affiliation(s)
- Tina M. Morrison
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States
| | | | | | | |
Collapse
|
18
|
Rapid High-Resolution Wavenumber Extraction from Ultrasonic Guided Waves Using Adaptive Array Signal Processing. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8040652] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|