1
|
Baydar O, Onem E, Mert A, Baksi BG. Evaluation of trabecular bone microstructure and cortical morphology using cone-beam and micro-CT images: impact of tube voltage setting. BMC Oral Health 2025; 25:664. [PMID: 40301841 PMCID: PMC12042375 DOI: 10.1186/s12903-025-05855-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2024] [Accepted: 03/20/2025] [Indexed: 05/01/2025] Open
Abstract
OBJECTIVE To evaluate the effect of various tube voltage (kV) settings on the accuracy of cone-beam computed tomography (CBCT) images in measuring trabecular microstructure and cortical morphology, using micro-CT (μCT) as the reference. METHODS Ten bone samples of sheep mandibles were scanned using both μCT and CBCT at three different tube voltage settings (80, 85, and 90 kV). Identical regions of interest (ROIs) on trabecular and cortical bones were analyzed in all images. Measurements of trabecular microstructure included bone volume fraction (BV/TV), trabecular thickness (Tb.Th) and space (Tb.Sp), while thickness (Ct.Th) and area (Ct.Ar) of cortical bone were measured to determine cortical morphology. Measurements were compared using paired t-test, while agreement between measurements of two modalities was assessed using Bland-Altman analysis. One-way ANOVA was used to determine differences in measurements of CBCT images at different kVs (p < 0.01). RESULTS Compared to μCT, CBCT overestimated trabecular parameters and Ct.Th but underestimated Ct.Ar, with high agreement observed between the methods. Significant differences were found for all measurements except BV/TV and Ct.Ar at all kVs. No differences were observed between CBCT measurements at different tube potentials. CONCLUSION The tube voltage of CBCT has minimal impact on the measurement accuracy of most microstructural parameters. BV/TV and Ct.Ar measurements may be particularly preferred for bone evaluations using CBCT images.
Collapse
Affiliation(s)
- Oğuzhan Baydar
- Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Eskisehir Osmangazi University, Eskişehir, Turkey.
| | - Erinc Onem
- School of Dentistry, Department of Oral and Maxillofacial Radiology, Ege University, Izmir, Turkey
| | - Ali Mert
- Faculty of Engineering and Architecture, Department of Engineering Sciences, Izmir Katip Celebi University, Izmir, Turkey
| | - B Guniz Baksi
- School of Dentistry, Department of Oral and Maxillofacial Radiology, Ege University, Izmir, Turkey
| |
Collapse
|
2
|
Tretto PHW, Griggs JA, Jodha KS, Duan Y, Marocho SMS, Della Bona A. Fatigue lifetime of reduced-diameter implants placed in different bone models. Dent Mater 2024; 40:1920-1926. [PMID: 39304478 DOI: 10.1016/j.dental.2024.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2024] [Revised: 09/05/2024] [Accepted: 09/10/2024] [Indexed: 09/22/2024]
Abstract
OBJECTIVES This study assessed the fatigue lifetime of reduced-diameter implants placed in either bovine rib or polymer-based bone model. METHODS Bovine ribs were classified according to the criteria proposed by Lekholm and Zarb and were analyzed for bone fraction. Fourteen dental implants (3.25 mm in diameter × 15 mm in length) were placed in bovine ribs used as a bone model. They were subjected to resonance frequency analysis. Stainless steel loading hemisphere caps were bonded on the abutments position at 30-degree angle and with a moment arm of 11 mm. Accelerated life testing using the step-stress method was conducted at 2 Hz with a stress ratio of 0.1 until fracture on a servo-hydraulic load frames machine (MTS). Results were compared with those of a previous study wherein implants were placed in a polymer-based bone model. Fatigue lifetime statistics (characteristic lifetime and Weibull modulus) of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined under an electron scanning microscope to determine the failure mode. RESULT The implants exhibited high stability quotient values (75.07 ± 3.81). Implants placed in bovine ribs showed better data dispersion and longer fatigue lifetime than those placed in polymer-based bone models, with no significant difference between groups. All fractures occurred in the implant body near the bone level and were indicative of fatigue fractures. SIGNIFICANCE Bovine ribs appear to be a more suitable material for accelerated life testing than the polymer-based material because of better data dispersion.
Collapse
Affiliation(s)
- Pedro Henrique Wentz Tretto
- Postgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Campus I - BR 285, Passo Fundo, RS 99052-900, Brazil.
| | - Jason Alan Griggs
- Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505, USA.
| | - Kartikeya Singh Jodha
- Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505, USA.
| | - Yuanyuan Duan
- Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505, USA.
| | - Susana María Salazar Marocho
- Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505, USA.
| | - Alvaro Della Bona
- Postgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Campus I - BR 285, Passo Fundo, RS 99052-900, Brazil.
| |
Collapse
|
3
|
Zheng Z, Fan Y, Zhang J, Wang J, Li Z. Cedrol alleviates postmenopausal osteoporosis in rats through inhibiting the activation of the NF-κB signaling pathway. In Vitro Cell Dev Biol Anim 2024:10.1007/s11626-024-00921-3. [PMID: 38814422 DOI: 10.1007/s11626-024-00921-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 04/22/2024] [Indexed: 05/31/2024]
Abstract
Pharmacological studies have shown that Cedrol (CE) exhibits extensive biological activities, including anti-inflammatory and analgesic. Moreover, it can inhibit the NF-κB pathway and the expression of various associated proteins. This study aimed to investigate the role of CE in postmenopausal osteoporosis. The results showed that intragastric administration of CE (10 and 20 mg/kg) significantly improved the bone microstructure damage and increased bone mineral density, trabecular bone volume, and bone trabecular thickness in ovariectomized (OVX) rats (p < 0.05). CE treatment additionally made a well-organized arrangement of bone trabeculae and improved its thickness and density. Compared with the OVX group, the levels of tartrate-resistant acid phosphatase from 5b and C-terminal telopeptide of type I collagen were significantly reduced by 42.75% and 49.27% in the OVX + CE rats (p < 0.05). TRAP staining visually showed that the number of osteoclasts in the femur tissue of CE-treated rats was less than that of the OVX group. The expressions of nuclear factor of activated T-cells, cytoplasmic 1, acid phosphatase 5, and cathepsin K in OVX + CE rats were significantly decreased by 51.61%, 46.07%, and 50.34% compared to the OVX group (p < 0.01). In addition, CE intervention effectively reduced the phosphorylation levels of P65 and IκBα and inhibited the NF-κB signaling pathway. Meanwhile, CE diminished the number of multinucleated osteoclasts induced by receptor activator for nuclear factor-κB ligand and hindered cell fusion as well as nuclear translocation of osteoclast precursor cells P65. In conclusion, CE inhibits osteoclastogenesis by suppressing the activation of the NF-κB signaling pathway, thereby alleviating postmenopausal osteoporosis.
Collapse
Affiliation(s)
- Zhen Zheng
- Department of Medical Technology, Liaoning Vocational College of Medicine, Shenyang, China.
| | - Ying Fan
- Department of Medical Technology, Liaoning Vocational College of Medicine, Shenyang, China
| | - Jingyun Zhang
- Department of Medical Technology, Liaoning Vocational College of Medicine, Shenyang, China
| | - Jian Wang
- Department of Medical Technology, Liaoning Vocational College of Medicine, Shenyang, China
| | - Zhenyu Li
- Department of Nursing, Liaoning Vocational College of Medicine, Shenyang, China
| |
Collapse
|
4
|
Jia Y, Han S, Li B, Liu C, Ta D. Backscatter measurement of cancellous bone using the ultrasound transit time spectroscopy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2670-2686. [PMID: 38639562 DOI: 10.1121/10.0025689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 03/26/2024] [Indexed: 04/20/2024]
Abstract
Recently, ultrasound transit time spectroscopy (UTTS) was proposed as a promising method for bone quantitative ultrasound measurement. Studies have showed that UTTS could estimate the bone volume fraction and other trabecular bone structure in ultrasonic through-transmission measurements. The goal of this study was to explore the feasibility of UTTS to be adapted in ultrasonic backscatter measurement and further evaluate the performance of backscattered ultrasound transit time spectrum (BS-UTTS) in the measurement of cancellous bone density and structure. First, taking ultrasonic attenuation into account, the concept of BS-UTTS was verified on ultrasonic backscatter signals simulated from a set of scatterers with different positions and intensities. Then, in vitro backscatter measurements were performed on 26 bovine cancellous bone specimens. After a logarithmic compression of the BS-UTTS, a linear fitting of the log-compressed BS-UTTS versus ultrasonic propagated distance was performed and the slope and intercept of the fitted line for BS-UTTS were determined. The associations between BS-UTTS parameters and cancellous bone features were analyzed using simple linear regression. The results showed that the BS-UTTS could make an accurate deconvolution of the backscatter signal and predict the position and intensity of the simulated scatterers eliminating phase interference, even the simulated backscatter signal was with a relatively low signal-to-noise ratio. With varied positions and intensities of the scatterers, the slope of the fitted line for the log-compressed BS-UTTS versus ultrasonic propagated distance (i.e., slope of BS-UTTS for short) yield a high agreement (r2 = 99.84%-99.96%) with ultrasonic attenuation in simulated backscatter signal. Compared with the high-density cancellous bone, the low-density specimen showed more abundant backscatter impulse response in the BS-UTTS. The slope of BS-UTTS yield a significant correlation with bone mineral density (r = 0.87; p < 0.001), BV/TV (r = 0.87; p < 0.001), and cancellous bone microstructures (r up to 0.87; p < 0.05). The intercept of BS-UTTS was also significantly correlated with bone densities (r = -0.87; p < 0.001) and trabecular structures (|r|=0.43-0.80; p < 0.05). However, the slope of the BS-UTTS underestimated attenuation when measurements were performed experimentally. In addition, a significant non-linear relationship was observed between the measured attenuation and the attenuation estimated by the slope of the BS-UTTS. This study demonstrated that the UTTS method could be adapted to ultrasonic backscatter measurement of cancellous bone. The derived slope and intercept of BS-UTTS could be used in the measurement of bone density and microstructure. The backscattered ultrasound transit time spectroscopy might have potential in the diagnosis of osteoporosis in the clinic.
Collapse
Affiliation(s)
- Yan Jia
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Shuai Han
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Boyi Li
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Chengcheng Liu
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
| | - Dean Ta
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
- Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China
| |
Collapse
|
5
|
Huang X, Zheng L, Zheng D, Li S, Fan Y, Lin Z, Huang S. Studying trabecular bone samples demonstrates a power law relation between deteriorated structure and mechanical properties - a study combining 3D printing with the finite element method. Front Endocrinol (Lausanne) 2023; 14:1061758. [PMID: 37334285 PMCID: PMC10273262 DOI: 10.3389/fendo.2023.1061758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 05/17/2023] [Indexed: 06/20/2023] Open
Abstract
Introduction The bone volume fraction (BV/TV) significantly contributes to the mechanical properties of trabecular bone. However, when studies compare normal trabeculae against osteoporotic trabeculae (in terms of BV/TV decrease), only an "average" mechanical result has been determined because of the limitation that no two trabecular structures are the same and that each unique trabecular structure can be mechanically tested only once. The mathematic relation between individual structural deterioration and mechanical properties during aging or the osteoporosis process has yet to be further clarified. Three-dimensional (3D) printing and micro-CT-based finite element method (μFEM) can assist in overcoming this issue. Methods In this study, we 3D printed structural-identical but BV/TV value-attenuated trabecular bones (scaled up ×20) from the distal femur of healthy and ovariectomized rats and performed compression mechanical tests. Corresponding μFEM models were also established for simulations. The tissue modulus and strength of 3D printed trabecular bones as well as the effective tissue modulus (denoted as Ez) derived from μFEM models were finally corrected by the side-artifact correction factor. Results The results showed that the tissue modulus corrected, strength corrected and Ez corrected exhibited a significant power law function of BV/TV in structural-identical but BV/TV value-attenuated trabecular samples. Discussion Using 3D printed bones, this study confirms the long-known relationship measured in trabecular tissue with varying volume fractions. In the future, 3D printing may help us attain better bone strength evaluations and even personal fracture risk assessments for patients who suffer from osteoporosis.
Collapse
Affiliation(s)
- Xiuhong Huang
- Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou, China
| | - Liqin Zheng
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Desheng Zheng
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Shaobin Li
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Yueguang Fan
- Department of Joint Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Ziling Lin
- Department of Orthopedic Trauma, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Shaohong Huang
- Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou, China
| |
Collapse
|
6
|
Sadoughi S, Bevill G, Morgan EF, Palepu V, Keaveny TM, Wear KA. Biomechanical structure-function relations for human trabecular bone - comparison of calcaneus, femoral neck, greater trochanter, proximal tibia, and vertebra. Comput Methods Biomech Biomed Engin 2023; 26:508-516. [PMID: 35579530 PMCID: PMC9669279 DOI: 10.1080/10255842.2022.2069465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 04/04/2022] [Accepted: 04/20/2022] [Indexed: 11/03/2022]
Abstract
MicroCT-based finite element models were used to compute power law relations for uniaxial compressive yield stress versus bone volume fraction for 78 cores of human trabecular bone from five anatomic sites. The leading coefficient of the power law for calcaneus differed from those for most of the other sites (p < 0.05). However, after normalizing by site-specific mean values, neither the leading coefficient (p > 0.5) nor exponent (p > 0.5) differed among sites, suggesting that a given percentage deviation from mean bone volume fraction has the same mechanical consequence for all sites investigated. These findings help explain the success of calcaneal x-ray and ultrasound measurements for predicting hip fracture risk.
Collapse
Affiliation(s)
- Saghi Sadoughi
- Department of Mechanical Engineering, University of California, Berkeley, CA
| | - Grant Bevill
- Mechanical Engineering Department, University of North Florida, Jacksonville, FL
| | - Elise F Morgan
- Departments of Mechanical Engineering and Biomedical Engineering, Boston University, Boston, MA
| | - Vivek Palepu
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| | - Tony M Keaveny
- Department of Mechanical Engineering, University of California, Berkeley, CA
- Department of Bioengineering, University of California, Berkeley, CA
| | - Keith A Wear
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| |
Collapse
|
7
|
Amini M, Reisinger A, Synek A, Hirtler L, Pahr D. The predictive ability of a QCT-FE model of the proximal femoral stiffness under multiple load cases is strongly influenced by experimental uncertainties. J Mech Behav Biomed Mater 2023; 139:105664. [PMID: 36657193 DOI: 10.1016/j.jmbbm.2023.105664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 01/03/2023] [Accepted: 01/05/2023] [Indexed: 01/11/2023]
Abstract
Despite significant improvements in terms of the predictive ability of Quantitative Computed Tomography based Finite Element (QCT-FE) models in estimating femoral strength (fracture load and stiffness), no substantial clinical adoption of this method has taken place to date. Narrowing the wide variability of FE results by standardizing the methodology and validation protocols, as well as reducing the uncertainties in the FEA process have been proposed as routes towards improved reliability. The aim of this study was to: First, validate a QCT-FE model of proximal femoral stiffness in multiple stance load cases, and second, using a parametric approach, determine the influence of select experimental and modeling parameters on the predictive ability of our model. Ten fresh frozen human femoral samples were tested in neutral stance, 15° adducted and 15° abducted load cases. Voxel-based linear-elastic QCT-FE models of the samples were generated to predict the models' stiffness values in all load cases. The base FE models were validated against the experimental results using linear regression. Thirty six deviated models were created using the minimum and maximum values of experiment-based "plausible range" for 18 parameters in 4 categories of embedding, loading, material, and segmentation. The predictive ability of the models were compared in terms of the coefficient of determination (R2) of the linear regression between the measured and predicted stiffness values in all load cases. Our model was capable of capturing 90% of the variation in the experimental stiffness of the samples in neutral stance position (R2 = 0.9, concordance correlation coefficient (CCC) = 0.93, percent root mean squared error (RMSE%) = 8.4%, slope and intercept not significantly different from unity and zero, respectively). Embedding and loading categories strongly affected the predictive ability of the models with an average percent difference in R2 of 4.36% ± 2.77 and 2.96% ± 1.69 for the stance-neutral load case, respectively. The performance of the models were significantly different in adducted and abducted load cases with their R2 dropping to 71% and 70%, respectively. Similarly, off-axes load cases were affected by the parameters differently compared to the neutral load case, with the loading parameter category imposing more than 10% difference on their R2, larger than all other categories. We also showed that automatically selecting the best performing plausible value for each parameter and each sample would result in a perfectly linear correlation (R2> 0.99) between the "tuned" model's predicted stiffness and experimental results. Based on our results, high sensitivity of the model performance to experimental parameters requires extra diligence in modeling the embedding geometry and the loading angles since these sources of uncertainty could dwarf the effects of material modeling and image processing parameters. The results of this study could help in improving the robustness of the QCT-FE models of proximal femur by limiting the uncertainties in the experimental and modeling steps.
Collapse
Affiliation(s)
- Morteza Amini
- Institute of Lightweight Design and Structural Biomechanics, TU Wien, Getreidemarkt 9, 1060, Vienna, Austria.
| | - Andreas Reisinger
- Division Biomechanics, Karl Landsteiner University of Health Sciences, Dr.-Karl-Dorrek-Straße 30, 3500 Krems an der Donau, Austria.
| | - Alexander Synek
- Institute of Lightweight Design and Structural Biomechanics, TU Wien, Getreidemarkt 9, 1060, Vienna, Austria.
| | - Lena Hirtler
- Center for Anatomy and Cell Biology, Medical University of Vienna, Währinger Straße 13, 1090, Vienna, Austria.
| | - Dieter Pahr
- Institute of Lightweight Design and Structural Biomechanics, TU Wien, Getreidemarkt 9, 1060, Vienna, Austria; Division Biomechanics, Karl Landsteiner University of Health Sciences, Dr.-Karl-Dorrek-Straße 30, 3500 Krems an der Donau, Austria.
| |
Collapse
|
8
|
Dutta SD, Ganguly K, Randhawa A, Patil TV, Patel DK, Lim KT. Electrically stimulated 3D bioprinting of gelatin-polypyrrole hydrogel with dynamic semi-IPN network induces osteogenesis via collective signaling and immunopolarization. Biomaterials 2023; 294:121999. [PMID: 36669301 DOI: 10.1016/j.biomaterials.2023.121999] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 12/30/2022] [Accepted: 01/08/2023] [Indexed: 01/15/2023]
Abstract
In recent years, three-dimensional (3D) bioprinting of conductive hydrogels has made significant progress in the fabrication of high-resolution biomimetic structures with gradual complexity. However, the lack of an effective cross-linking strategy, ideal shear-thinning, appropriate yield strength, and higher print fidelity with excellent biofunctionality remains a challenge for developing cell-laden constructs, hindering the progress of extrusion-based 3D printing of conductive polymers. In this study, a highly stable and conductive bioink was developed based on polypyrrole-grafted gelatin methacryloyl (GelMA-PPy) with a triple cross-linking (thermo-photo-ionically) strategy for direct ink writing-based 3D printing applications. The triple-cross-linked hydrogel with dynamic semi-inner penetrating polymer network (semi-IPN) displayed excellent shear-thinning properties, with improved shape fidelity and structural stability during 3D printing. The as-fabricated hydrogel ink also exhibited "plug-like non-Newtonian" flow behavior with minimal disturbance. The bioprinted GelMA-PPy-Fe hydrogel showed higher cytocompatibility (93%) of human bone mesenchymal stem cells (hBMSCs) under microcurrent stimulation (250 mV/20 min/day). Moreover, the self-supporting and tunable mechanical properties of the GelMA-PPy bioink allowed 3D printing of high-resolution biological architectures. As a proof of concept, we printed a full-thickness rat bone model to demonstrate the structural stability. Transcriptomic analysis revealed that the 3D bioprinted hBMSCs highly expressed gene hallmarks for NOTCH/mitogen-activated protein kinase (MAPK)/SMAD signaling while down-regulating the Wnt/β-Catenin and epigenetic signaling pathways during osteogenic differentiation for up to 7 days. These results suggest that the developed GelMA-PPy bioink is highly stable and non-toxic to hBMSCs and can serve as a promising platform for bone tissue engineering applications.
Collapse
Affiliation(s)
- Sayan Deb Dutta
- Department of Biosystems Engineering, Kangwon National University, Chuncheon, 24341, Republic of Korea
| | - Keya Ganguly
- Department of Biosystems Engineering, Kangwon National University, Chuncheon, 24341, Republic of Korea
| | - Aayushi Randhawa
- Department of Biosystems Engineering, Kangwon National University, Chuncheon, 24341, Republic of Korea; Interdisciplinary Program in Smart Agriculture, Kangwon National University, Chuncheon, 24341, Republic of Korea
| | - Tejal V Patil
- Department of Biosystems Engineering, Kangwon National University, Chuncheon, 24341, Republic of Korea; Interdisciplinary Program in Smart Agriculture, Kangwon National University, Chuncheon, 24341, Republic of Korea
| | - Dinesh K Patel
- Institute of Forest Sciences, Kangwon National University, Chuncheon, 24341, Republic of Korea
| | - Ki-Taek Lim
- Department of Biosystems Engineering, Kangwon National University, Chuncheon, 24341, Republic of Korea; Interdisciplinary Program in Smart Agriculture, Kangwon National University, Chuncheon, 24341, Republic of Korea; Institute of Forest Sciences, Kangwon National University, Chuncheon, 24341, Republic of Korea; Biomechagen Co., Ltd., Chuncheon, 24341, Republic of Korea.
| |
Collapse
|
9
|
Alomari A, Langton C. Comparison of deconvoluted-convoluted reconstituted ultrasound signals with their experimental original in a porous composite, cancellous bone. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2023. [DOI: 10.1016/j.jrras.2022.100519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
10
|
Zheng L, Huang X, Li C, Li P, Lin Z, Huang S. 3D printed trabeculae conditionally reproduce the mechanical properties of the actual trabeculae - A preliminary study. Heliyon 2022; 8:e12101. [PMID: 36544825 PMCID: PMC9761705 DOI: 10.1016/j.heliyon.2022.e12101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Revised: 10/13/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
Three-dimensional (3D) printing has been used to fabricate synthetic trabeculae models and to test mechanical behavior that cannot be recognized in the actual sample, but the extent to which 3D printed trabeculae replicate the mechanical behavior of the actual trabeculae remains to be quantified. The aim of this study was to evaluate the accuracy of 3D printed trabeculae in reproducing the mechanical properties of the corresponding actual trabeculae. Twelve human trabecular cubes (5 × 5 × 5 mm) were scanned by micro-CT to form the trabecular 3D model. Each trabecular 3D model was scaled ×2-, ×3-, ×4- and ×5-fold and then printed twice at a layer thickness of 60 μm using poly (lactic acid) (PLA). The actual trabecular cubes and the 3D-printed trabecular cubes were first compressed under a loading rate of 1 mm/min; another replicated stack of 3D-printed trabecular cubes was compressed under a strain rate of 0.2/min. The results showed that the stiffness of the printed cubes tended to increase, while the strength tended to converge when the magnification increased under the two loading conditions. The strain rate effect was found in the printed cubes. The correlation coefficient (R2) of the mechanical properties between the printed and actual trabeculae can reach up to 0.94, especially under ×3-, ×4- and ×5-fold magnification. In conclusion, 3D printing could be a potential tool to evaluate the mechanical behavior of actual trabecular tissue in vitro and may help in the future to predict the risk of fracture and even personalize the treatment evaluation for osteoporosis and other trabecular bone pathologies.
Collapse
Affiliation(s)
- Liqin Zheng
- The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xiuhong Huang
- Stomatological Hospital, Southern Medical University, Guangzhou, China
- School of Stomatology, Southern Medical University, Guangzhou, China
| | - Chihung Li
- International College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Pengfei Li
- Department of Orthopedics, The Affiliated Jiangmen Traditional Chinese Medicine Hospital of Jinan University, Jiangmen, China
- Department of Orthopedics, Jiangmen Central Hospital, Affiliated Jiangmen Hospital of Sun Yat-sen University, Jiangmen, China
| | - Ziling Lin
- Department of Orthopedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Shaohong Huang
- Stomatological Hospital, Southern Medical University, Guangzhou, China
- School of Stomatology, Southern Medical University, Guangzhou, China
| |
Collapse
|
11
|
D’Erminio DN, Krishnamoorthy D, Lai A, Hoy RC, Natelson DM, Poeran J, Torres A, Laudier DM, Nasser P, Vashishth D, Illien-Jünger S, Iatridis JC. High fat diet causes inferior vertebral structure and function without disc degeneration in RAGE-KO mice. J Orthop Res 2022; 40:1672-1686. [PMID: 34676612 PMCID: PMC9021327 DOI: 10.1002/jor.25191] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 08/12/2021] [Accepted: 09/30/2021] [Indexed: 02/04/2023]
Abstract
Back pain and spinal pathologies are associated with obesity in juveniles and adults, yet studies identifying causal relationships are lacking and none investigate sex differences. This study determined if high fat (HF) diet causes structural and functional changes to vertebrae and intervertebral discs (IVDs); if these changes are modulated in mice with systematic ablation for the receptor for advanced glycation endproducts (RAGE-KO); and if these changes are sex-dependent. Wild-type (WT) and RAGE-KO mice were fed a low fat (LF) or HF diet for 12 weeks starting at 6 weeks, representing the juvenile population. HF diet led to weight/fat gain, glucose intolerance, and increased cytokine levels (IL-5, MIG, and RANTES); with less fat gain in RAGE-KO females. Most importantly, HF diet reduced vertebral trabecular bone volume fraction and compressive and shear moduli, without a modifying effect of RAGE-KO, but with a more pronounced effect in females. HF diet caused reduced cortical area fraction only in WT males. Neither HF diet nor RAGE-KO affected IVD degeneration grade. Biomechanical properties of coccygeal motion segments were affected by RAGE-KO but not diet, with some interactions identified. In conclusion, HF diet resulted in inferior vertebral structure and function with some sex differences, no IVD degeneration, and few modifying effects of RAGE-KO. These structural and functional deficiencies with HF diet provide further evidence that diet can affect spinal structures and may increase the risk for spinal injury and degeneration with aging and additional stressors. Back pain and spinal pathologies are associated with obesity in juveniles and adults, yet studies identifying causal relationships are lacking and none investigate sex differences.
Collapse
Affiliation(s)
- Danielle N D’Erminio
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
- Dept. of Biomedical Engineering, The City College of New York at CUNY, NY, NY
| | - Divya Krishnamoorthy
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
- 3DBio Therapeutics, New York, NY
| | - Alon Lai
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
| | - Robert C Hoy
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
| | - Devorah M Natelson
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
| | - Jashvant Poeran
- Dept. of Population Health Science & Policy, and Medicine, Mount Sinai Health System, New York, NY
| | - Andrew Torres
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
| | - Damien M Laudier
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
| | - Philip Nasser
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
| | - Deepak Vashishth
- Ctr. for Biotechnology & Interdisciplinary Studies, Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY
| | - Svenja Illien-Jünger
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
- Emory University School of Medicine, Department of Orthopaedics, Atlanta, GA
| | - James C Iatridis
- Leni & Peter W. May Dept. of Orthopaedics, Mount Sinai Health System, New York, NY
| |
Collapse
|
12
|
Multi-objective Shape Optimization of Bone Scaffolds: Enhancement of Mechanical Properties and Permeability. Acta Biomater 2022; 146:317-340. [PMID: 35533924 DOI: 10.1016/j.actbio.2022.04.051] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 04/05/2022] [Accepted: 04/29/2022] [Indexed: 11/23/2022]
Abstract
Porous scaffolds have recently attracted attention in bone tissue engineering. The implanted scaffolds are supposed to satisfy the mechanical and biological requirements. In this study, two porous structures named MFCC-1 (modified face centered cubic-1) and MFCC-2 (modified face centered cubic-2) are introduced. The proposed porous architectures are evaluated, optimized, and tested to enhance mechanical and biological properties. The geometric parameters of the scaffolds with porosities ranging from 70% to 90% are optimized to find a compromise between the effective Young's modulus and permeability, as well as satisfying the pore size and specific surface area requirements. To optimize the effective Young's modulus and permeability, we integrated a mathematical formulation, finite element analysis, and computational fluid dynamics simulations. For validation, the optimized scaffolds were 3D-printed, tested, and compared with two different orthogonal cylindrical struts (OCS) scaffold architectures. The MFCC designs are preferred to the generic OCS scaffolds from various perspectives: a) the MFCC architecture allows scaffold designs with porosities up to 96%; b) the very porous architecture of MFCC scaffolds allows achieving high permeabilities, which could potentially improve the cell diffusion; c) despite having a higher porosity compared to the OCS scaffolds, MFCC scaffolds improve mechanical performance regarding Young's modulus, stress concentration, and apparent yield strength; d) the proposed structures with different porosities are able to cover all the range of permeability for the human trabecular bones. The optimized MFCC designs have simple architectures and can be easily fabricated and used to improve the quality of load-bearing orthopedic scaffolds. STATEMENT OF SIGNIFICANCE: Porous scaffolds are increasingly being studied to repair large bone defects. A scaffold is supposed to withstand mechanical loads and provide an appropriate environment for bone cell growth after implantation. These mechanical and biological requirements are usually contradicting; improving the mechanical performance would require a reduction in porosity and a lower porosity is likely to reduce the biological performance of the scaffold. Various studies have shown that the mechanical and biological performance of bone scaffolds can be improved by internal architecture modification. In this study, we propose two scaffold architectures named MFCC-1 and MFCC-2 and provide an optimization framework to simultaneously optimize their stiffness and permeability to improve their mechanical and biological performances.
Collapse
|
13
|
Shape optimization of orthopedic porous scaffolds to enhance mechanical performance. J Mech Behav Biomed Mater 2022; 128:105098. [DOI: 10.1016/j.jmbbm.2022.105098] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 11/02/2021] [Accepted: 01/17/2022] [Indexed: 11/19/2022]
|
14
|
Assessing underlying bone quality in spine surgery patients: a narrative review of dual-energy X-ray absorptiometry (DXA) and alternatives. Spine J 2021; 21:321-331. [PMID: 32890786 DOI: 10.1016/j.spinee.2020.08.020] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 08/15/2020] [Accepted: 08/29/2020] [Indexed: 02/06/2023]
Abstract
Poor bone quality and low bone mineral density (BMD) have been previously tied to higher rates of postoperative mechanical complications in patients undergoing spinal fusion. These include higher rates of proximal junctional kyphosis, screw pullout, pseudoarthrosis, and interbody subsidence. For these reasons, accurate preoperative assessment of a patient's underlying bone quality is paramount for all elective procedures. Dual-energy X-ray absorptiometry (DXA) is currently considered to be the gold standard for assessing BMD. However, a growing body of research has suggested that in vivo assessments of BMD using DXA are inaccurate and have, at best, moderate correlations to postoperative mechanical complications. Consequently, there have been investigations into using alternative methods for assessing in vivo bone quality, including using computed tomography (CT) and magnetic resonance imaging (MRI) volumes that are commonly obtained as part of surgical evaluation. Here we review the data regarding the accuracy of DXA for the evaluation of spine bone quality and describe the alternative imaging modalities currently under investigation.
Collapse
|
15
|
Sato A, Yanagi T, Yamaguchi Y, Taniguchi Y, Kido H, Ohno J. Effect of DNA/protamine complex paste on bone augmentation of the mandible: A pilot study on dogs. Arch Oral Biol 2020; 115:104729. [PMID: 32387858 DOI: 10.1016/j.archoralbio.2020.104729] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Revised: 03/16/2020] [Accepted: 04/06/2020] [Indexed: 12/21/2022]
Abstract
OBJECTIVE Our previous studies found that a salmon DNA-based scaffold containing protamine promoted bone regeneration of the calvarial defects of rats. The aim of the present pilot study was to examine the influence of the DNA/protamine (DP) complex on bone regeneration of a saddle type, alveolar ridge defects of the dog mandible. DESIGN Alveolar ridge defects were performed in the mandibles of five adult female beagles. The following three treatment modalities were randomly allocated: (1) the DP complex paste, (2) a beta-tricalcium phosphate (β-TCP), and (3) a blank (control). Healing of bone defects were evaluated by periapical radiography, micro-computed tomography (micro-CT), and histology. RESULTS Periodical radiographic images revealed that a higher percentage of regenerated bone height was consistently achieved in the DP group, as compared with blank controls. All three-dimensional, sagittal, and coronal images of micro-CT showed increased amounts of newly formed bone and a greater bone volume/ tissue volume ratio, as compared with the blank and β-TCP groups. In contrast, there was no significant difference in bone mineral density among the groups. Histological analysis confirmed that the alveolar bone defects were filled with newly formed bone with mature and compact properties in the DP group. CONCLUSIONS These findings indicate that the DP complexes enhanced regeneration of vertical alveolar bone defects of the dog mandible.
Collapse
Affiliation(s)
- Ayako Sato
- Section of Oral Implantology, Department of Oral Rehabilitation, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan; Research Center for Regenerative Medicine, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan
| | - Tsukasa Yanagi
- Section of Oral Implantology, Department of Oral Rehabilitation, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan; Research Center for Regenerative Medicine, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan
| | - Yuichiro Yamaguchi
- Section of Fixed Prosthodontics, Department of Oral Rehabilitation, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan
| | - Yusuke Taniguchi
- Section of Oral Implantology, Department of Oral Rehabilitation, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan
| | - Hirofumi Kido
- Section of Oral Implantology, Department of Oral Rehabilitation, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan
| | - Jun Ohno
- Research Center for Regenerative Medicine, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan; Oral Medicine Research Center, Fukuoka Dental College, Tamura, Sawara-ku, Fukuoka, Japan.
| |
Collapse
|
16
|
Wear KA. Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:454-482. [PMID: 31634127 PMCID: PMC7050438 DOI: 10.1109/tuffc.2019.2947755] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Ultrasound is now a clinically accepted modality in the management of osteoporosis. The most common commercial clinical devices assess fracture risk from measurements of attenuation and sound speed in cancellous bone. This review discusses fundamental mechanisms underlying the interaction between ultrasound and cancellous bone. Because of its two-phase structure (mineralized trabecular network embedded in soft tissue-marrow), its anisotropy, and its inhomogeneity, cancellous bone is more difficult to characterize than most soft tissues. Experimental data for the dependencies of attenuation, sound speed, dispersion, and scattering on ultrasound frequency, bone mineral density, composition, microstructure, and mechanical properties are presented. The relative roles of absorption, scattering, and phase cancellation in determining attenuation measurements in vitro and in vivo are delineated. Common speed of sound metrics, which entail measurements of transit times of pulse leading edges (to avoid multipath interference), are greatly influenced by attenuation, dispersion, and system properties, including center frequency and bandwidth. However, a theoretical model has been shown to be effective for correction for these confounding factors in vitro and in vivo. Theoretical and phantom models are presented to elucidate why cancellous bone exhibits negative dispersion, unlike soft tissue, which exhibits positive dispersion. Signal processing methods are presented for separating "fast" and "slow" waves (predicted by poroelasticity theory and supported in cancellous bone) even when the two waves overlap in time and frequency domains. Models to explain dependencies of scattering on frequency and mean trabecular thickness are presented and compared with measurements. Anisotropy, the effect of the fluid filler medium (marrow in vivo or water in vitro), phantoms, computational modeling of ultrasound propagation, acoustic microscopy, and nonlinear properties in cancellous bone are also discussed.
Collapse
|
17
|
Langton CM. Design of a 3D-printed ultrasound phase-interference compensator (UPIC) for various test sample environment scenarios. Biomed Phys Eng Express 2019. [DOI: 10.1088/2057-1976/ab03ae] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
18
|
Liu C, Li B, Diwu Q, Li Y, Zhang R, Ta D, Wang W. Relationships of Ultrasonic Backscatter With Bone Densities and Microstructure in Bovine Cancellous Bone. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2311-2321. [PMID: 30575524 DOI: 10.1109/tuffc.2018.2872084] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This study was designed to investigate the associations among ultrasonic backscatter, bone densities, and microstructure in bovine cancellous bone. Ultrasonic backscatter measurements were performed on 33 bovine cancellous bone specimens with a 2.25-MHz transducer. Ultrasonic apparent backscatter parameters ("apparent" means not compensating for ultrasonic attenuation and diffraction) were calculated with optimal signals of interest. The results showed that ultrasonic backscatter was significantly related to bone densities and microstructure ( R2 = 0.17 -0.88 and ). After adjusting the correlations by bone mineral density (BMD), the bone apparent density (BAD) and some trabecular structural features still contributed significantly to the adjusted correlations, with moderate additional variance explained ( ∆R2 = 9.7 % at best). Multiple linear regressions revealed that both BAD and trabecular structure contributed significantly and independently to the prediction of ultrasound backscatter (adjusted R2 = 0.75 -0.89 and ), explaining an additional 14% of the variance at most, compared with that of BMD measurements alone. The results proved that ultrasonic backscatter was primarily determined by BAD, not BMD, but the combination of bone structure and densities could achieve encouragingly better performances (89% of the variance explained at best) in predicting backscatter properties. This study demonstrated that ultrasonic apparent backscatter might provide additional density and structural features unrelated to current BMD measurement. Therefore, we suggest that ultrasonic backscatter measurement could play a more important role in cancellous bone evaluation.
Collapse
|
19
|
Avila Gonzalez CA, Driscoll M, Schleip R, Wearing S, Jacobson E, Findley T, Klingler W. Frontiers in fascia research. J Bodyw Mov Ther 2018; 22:873-880. [PMID: 30368329 DOI: 10.1016/j.jbmt.2018.09.077] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 09/06/2018] [Indexed: 01/07/2023]
Abstract
Basic sciences are the backbone of every clear understanding of how the body is composed and how different structures and functions are connected with each other. It is obvious that there is a huge variability in human beings - not only in terms of the outer appearance such as measurements of height, weight, muscle mass and other physical properties, but also with respect to metabolic and functional parameters. This article highlights recent developments of research activities in the field of fascia sciences with a special emphasis on assessment strategies as the basis of further studies. Anatomical and histological studies show that fascial tissue is highly variable in terms of density, stiffness, and other parameters such as metabolic and humoral activity. Moreover, it encompasses nerves and harbours a system of micro-channels, also known as the primo vascular system. As ultrasound is a widely available method, its use is appealing not only for imaging of fascial structures, but also for thorough scientific analysis. Unlike most other imaging technologies, US has the advantage of real-time analysis of active or passive movements. In addition, other assessment methods for fascial tissue are discussed. In conclusion, fascial tissue plays an important role not only in functional anatomy, but also in evolutionary and molecular biology, sport, and exercise science as well as in numerous therapeutic approaches. A high density of nerves is found in fascial tissue. Knowledge of individual characteristics, especially by visualizing with ultrasound, leads to personalized therapeutic approaches, such as in pain therapy.
Collapse
Affiliation(s)
- Carla Alessandra Avila Gonzalez
- Department of Anaesthesiology, Intensive Care, Palliative Care, and Pain Medicine, BG University Hospital Bergmannsheil, Ruhr University Bochum, Germany; Department of Anaesthesiology and Intensive Care Medicine, Hessing Foundation, Augsburg, Germany.
| | - Mark Driscoll
- Department of Mechanical Engineering, McGill University, Canada
| | - Robert Schleip
- Fascia Research Group, Department of Experimental Anaesthesiology, Ulm University, Germany
| | - Scott Wearing
- Faculty of Health School - Clinical Sciences, Queensland University of Technology, Brisbane, Australia
| | - Eric Jacobson
- Department of Global Health & Social Medicine, Harvard Medical School, Boston, USA; Motion Analysis Laboratory, Department of Physical Medicine & Rehabilitation, Spaulding Rehabilitation Hospital, USA
| | - Tom Findley
- Rutgers New Jersey Medical School, State University of New Jersey, USA
| | - Werner Klingler
- Fascia Research Group, Department of Experimental Anaesthesiology, Ulm University, Germany; Faculty of Health School - Clinical Sciences, Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
20
|
Langton CM, AlQahtani SM, Wille ML. A 3D-printed passive ultrasound phase-interference compensator for reduced wave degradation in cancellous bone - an experimental study in replica models. J Tissue Eng 2018; 9:2041731418766418. [PMID: 29636893 PMCID: PMC5888813 DOI: 10.1177/2041731418766418] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2017] [Accepted: 02/26/2018] [Indexed: 11/18/2022] Open
Abstract
The current ‘active’ solution to overcome the impediment of ultrasound wave degradation associated with transit-time variation in complex tissue structures, such as the skull, is to vary the transmission delay of ultrasound pulses from individual transducer elements. This article considers a novel ‘passive’ solution in which constant transit time is achieved by propagating through an additional material layer positioned between the ultrasound transducer and the test sample. To test the concept, replica models based on four cancellous bone natural tissue samples and their corresponding passive ultrasound phase-interference compensator were 3D-printed. Normalised broadband ultrasound attenuation was used as a quantitative measure of wave degradation, performed in transmission mode at a frequency of 1 MHz and yielding a reduction ranging from 57% to 74% when the ultrasound phase-interference compensator was incorporated. It is suggested that the passive compensator offers a broad utility and, hence, it may be applied to any ultrasound transducer, of any complexity (single element or array), frequency and dimension.
Collapse
Affiliation(s)
- Christian M Langton
- Science and Engineering, Queensland University of Technology, Brisbane, QLD, Australia.,Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia.,Laboratory of Ultrasonic Electronics, Doshisha University, Kyotanabe, Japan
| | - Saeed M AlQahtani
- Science and Engineering, Queensland University of Technology, Brisbane, QLD, Australia.,Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia.,University College in Al Jamoom, Umm Al-Qura University, Mecca, Saudi Arabia
| | - Marie-Luise Wille
- Science and Engineering, Queensland University of Technology, Brisbane, QLD, Australia.,Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|