1
|
Wang X, Yuan X, Yan R, Song J, Ren C, Li H, Li H, Yu J. Purification, characterization, and functional validation of a novel casein complex enzyme hydrolysate-binding calcium. Food Chem 2025; 476:143438. [PMID: 39983476 DOI: 10.1016/j.foodchem.2025.143438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2024] [Revised: 02/12/2025] [Accepted: 02/13/2025] [Indexed: 02/23/2025]
Abstract
Food Peptide Calcium Chelate was an excellent calcium supplement. The aim of this study was to isolate peptides with high calcium binding activity from a mixture of casein hydrolyzed peptides, to determine their structural characteristics and to verify their function. Firstly, micellar casein was hydrolyzed by a combination of flavor protease and trypsin. Casein hydrolysate peptides (CHP) with high calcium chelating activity were obtained by three purifications and characterized by high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), mass spectrometry (MS/MS), and fourier transform infrared spectroscopy (FTIR). The results showed that the purified polypeptide (Tyr-Gln-Glu-Pro) had high calcium binding capacity (70.10 ± 4.23 μg/mg). Animal experiments confirmed that YQEP-Ca was effective in improving the bone microarchitecture of rats, and that the low-calcium-content's medium-dose group also had better utilization than the inorganic and unchelated calcium groups. Therefore, the YQEP-Ca obtained in this study provides new clues for the development of various products.
Collapse
Affiliation(s)
- Xin Wang
- College of Food Science and Engineering, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Xianwei Yuan
- College of Food Science and Engineering, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Ruyu Yan
- College of Food Science and Engineering, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Jianchen Song
- College of Food Science and Engineering, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Chuan Ren
- College of Food Science and Engineering, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Hongbo Li
- College of Food Science and Engineering, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Hongjuan Li
- College of Food Science and Engineering, Tianjin University of Science & Technology, Tianjin 300457, China.
| | - Jinghua Yu
- College of Food Science and Engineering, Tianjin University of Science & Technology, Tianjin 300457, China.
| |
Collapse
|
2
|
Todd L, Chin MHW, Coppens MO. Two conjectures on 3D Voronoi structures: a toolkit with biomedical case studies. MOLECULAR SYSTEMS DESIGN & ENGINEERING 2024; 9:912-919. [PMID: 39205672 PMCID: PMC11348831 DOI: 10.1039/d4me00036f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 05/19/2024] [Indexed: 09/04/2024]
Abstract
3D Voronoi scaffolds are widely applied in the field of additive manufacturing as they are known for their light weight structural resilience and share many topological similarities to various natural (bone, tumours, lymph node) and synthetic environments (foam, functionally gradient porous materials). Unfortunately, the structural design features that promote these topological similarities (such as the number of vertices) are often unpredictable and require the trial and error of varying design features to achieve the desired 3D Voronoi structure. This article provides a toolkit, consisting of equations, based on over 12 000 3D Voronoi structures. These equations allow design features, such as the number of generating points (G), to be efficiently and accurately predicted based on the desired structural parameters (within ±3G). Based on these equations we are proposing, to the best of our knowledge, two new mathematical conjectures that relate the number of vertices or edges, and the average edge length to G in Voronoi structures. These equations have been validated for a wide range of parameter values and Voronoi network sizes. A design code is provided allowing any of over 12 000 structures to be selected, easily adjusted based on user requirements, and 3D printed. Biomedical case studies relevant to T-cell culturing, bone scaffolds and kidney tumours are presented to illustrate the design code.
Collapse
Affiliation(s)
- Lucy Todd
- Centre for Nature Inspired Engineering & Department of Chemical Engineering, University College London Torrington Place London WC1E 7JE United Kingdom
| | - Matthew H W Chin
- Centre for Nature Inspired Engineering & Department of Chemical Engineering, University College London Torrington Place London WC1E 7JE United Kingdom
| | - Marc-Olivier Coppens
- Centre for Nature Inspired Engineering & Department of Chemical Engineering, University College London Torrington Place London WC1E 7JE United Kingdom
| |
Collapse
|
3
|
Alonso-Fernández I, Haugen HJ, Nogueira LP, López-Álvarez M, González P, López-Peña M, González-Cantalapiedra A, Muñoz-Guzón F. Enhanced Bone Healing in Critical-Sized Rabbit Femoral Defects: Impact of Helical and Alternate Scaffold Architectures. Polymers (Basel) 2024; 16:1243. [PMID: 38732711 PMCID: PMC11085737 DOI: 10.3390/polym16091243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 04/20/2024] [Accepted: 04/26/2024] [Indexed: 05/13/2024] Open
Abstract
This study investigates the effect of scaffold architecture on bone regeneration, focusing on 3D-printed polylactic acid-bioceramic calcium phosphate (PLA-bioCaP) composite scaffolds in rabbit femoral condyle critical defects. We explored two distinct scaffold designs to assess their influence on bone healing and scaffold performance. Structures with alternate (0°/90°) and helical (0°/45°/90°/135°/180°) laydown patterns were manufactured with a 3D printer using a fused deposition modeling technique. The scaffolds were meticulously characterized for pore size, strut thickness, porosity, pore accessibility, and mechanical properties. The in vivo efficacy of these scaffolds was evaluated using a femoral condyle critical defect model in eight skeletally mature New Zealand White rabbits. Then, the results were analyzed micro-tomographically, histologically, and histomorphometrically. Our findings indicate that both scaffold architectures are biocompatible and support bone formation. The helical scaffolds, characterized by larger pore sizes and higher porosity, demonstrated significantly greater bone regeneration than the alternate structures. However, their lower mechanical strength presented limitations for use in load-bearing sites.
Collapse
Affiliation(s)
- Iván Alonso-Fernández
- Anatomy, Animal Production and Veterinary Clinical Sciences Department, Veterinary Faculty, Universidade de Santiago de Compostela, Campus Universitario s/n, 27002 Lugo, Spain; (M.L.-P.); (A.G.-C.); (F.M.-G.)
| | - Håvard Jostein Haugen
- Department of Biomaterials, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, 0317 Oslo, Norway; (H.J.H.); (L.P.N.)
| | - Liebert Parreiras Nogueira
- Department of Biomaterials, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, 0317 Oslo, Norway; (H.J.H.); (L.P.N.)
| | - Miriam López-Álvarez
- Centro de Investigación en Tecnologías, Energía y Procesos Industriales (CINTECX), Universidade de Vigo, Grupo de Novos Materiais, 36310 Vigo, Spain; (M.L.-Á.); (P.G.)
- Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, 36213 Vigo, Spain
| | - Pío González
- Centro de Investigación en Tecnologías, Energía y Procesos Industriales (CINTECX), Universidade de Vigo, Grupo de Novos Materiais, 36310 Vigo, Spain; (M.L.-Á.); (P.G.)
- Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, 36213 Vigo, Spain
| | - Mónica López-Peña
- Anatomy, Animal Production and Veterinary Clinical Sciences Department, Veterinary Faculty, Universidade de Santiago de Compostela, Campus Universitario s/n, 27002 Lugo, Spain; (M.L.-P.); (A.G.-C.); (F.M.-G.)
| | - Antonio González-Cantalapiedra
- Anatomy, Animal Production and Veterinary Clinical Sciences Department, Veterinary Faculty, Universidade de Santiago de Compostela, Campus Universitario s/n, 27002 Lugo, Spain; (M.L.-P.); (A.G.-C.); (F.M.-G.)
| | - Fernando Muñoz-Guzón
- Anatomy, Animal Production and Veterinary Clinical Sciences Department, Veterinary Faculty, Universidade de Santiago de Compostela, Campus Universitario s/n, 27002 Lugo, Spain; (M.L.-P.); (A.G.-C.); (F.M.-G.)
| |
Collapse
|
4
|
Giorgio I, dell'Isola F, Andreaus U, Misra A. An orthotropic continuum model with substructure evolution for describing bone remodeling: an interpretation of the primary mechanism behind Wolff's law. Biomech Model Mechanobiol 2023; 22:2135-2152. [PMID: 37542620 PMCID: PMC10613191 DOI: 10.1007/s10237-023-01755-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 07/16/2023] [Indexed: 08/07/2023]
Abstract
We propose a variational approach that employs a generalized principle of virtual work to estimate both the mechanical response and the changes in living bone tissue during the remodeling process. This approach provides an explanation for the adaptive regulation of the bone substructure in the context of orthotropic material symmetry. We specifically focus upon the crucial gradual adjustment of bone tissue as a structural material that adapts its mechanical features, such as materials stiffnesses and microstructure, in response to the evolving loading conditions. We postulate that the evolution process relies on a feedback mechanism involving multiple stimulus signals. The mechanical and remodeling behavior of bone tissue is clearly a complex process that is difficult to describe within the framework of classical continuum theories. For this reason, a generalized continuum elastic theory is employed as a proper mathematical context for an adequate description of the examined phenomenon. To simplify the investigation, we considered a two-dimensional problem. Numerical simulations have been performed to illustrate bone evolution in a few significant cases: the bending of a rectangular cantilever plate and a three-point flexure test. The results are encouraging because they can replicate the optimization process observed in bone remodeling. The proposed model provides a likely distribution of stiffnesses and accurately represents the arrangement of trabeculae macroscopically described by the orthotropic symmetry directions, as supported by experimental evidence from the trajectorial theory.
Collapse
Affiliation(s)
- Ivan Giorgio
- Department of Civil, Construction-Architectural and Environmental Engineering (DICEAA), University of L'Aquila, 1, P.zza Ernesto Pontieri, Monteluco di Roio, L'Aquila, 67100, Italy.
- International Research Center for the Mathematics and Mechanics of Complex Systems (M &MoCS), University of L'Aquila, 1, P.zza Ernesto Pontieri, Monteluco di Roio, L'Aquila, 67100, Italy.
| | - Francesco dell'Isola
- Department of Civil, Construction-Architectural and Environmental Engineering (DICEAA), University of L'Aquila, 1, P.zza Ernesto Pontieri, Monteluco di Roio, L'Aquila, 67100, Italy
- International Research Center for the Mathematics and Mechanics of Complex Systems (M &MoCS), University of L'Aquila, 1, P.zza Ernesto Pontieri, Monteluco di Roio, L'Aquila, 67100, Italy
- Faculty of Mechanical and Industrial Engineering, Warsaw University of Technology, ul. Narbutta 85, Warsaw, 02-524, Poland
- CNRS Fellow, ENS Paris-Saclay, 4, avenue des Sciences, Gif-sur-Yvette, 91190, France
| | - Ugo Andreaus
- Department of Structural and Geotechnical Engineering (DISG), Università di Roma La Sapienza, 18, Via Eudossiana, Rome, 00184, Italy
| | - Anil Misra
- International Research Center for the Mathematics and Mechanics of Complex Systems (M &MoCS), University of L'Aquila, 1, P.zza Ernesto Pontieri, Monteluco di Roio, L'Aquila, 67100, Italy
- Civil, Environmental and Architectural Engineering Department (CEAE), The University of Kansas, 1530 W. 15th Street, Learned Hall, Lawrence, 66045-7609, Kansas, USA
| |
Collapse
|
5
|
Haque E, Xiao P, Ye K, Wang X. Probability-based approach for characterization of microarchitecture and its effect on elastic properties of trabecular bone. J Mech Behav Biomed Mater 2022; 131:105254. [DOI: 10.1016/j.jmbbm.2022.105254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 01/26/2022] [Accepted: 02/07/2022] [Indexed: 10/18/2022]
|
6
|
Yamada S, Fukasawa K, Suzuki Y, Takahashi Y, Todoh M, Tadano S. The role of geometrical features of the microarchitecture in the cancellous stiffness of the bovine femoral bone. Med Eng Phys 2022; 105:103823. [DOI: 10.1016/j.medengphy.2022.103823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 04/28/2022] [Accepted: 05/22/2022] [Indexed: 11/16/2022]
|
7
|
Sun SZ, Jiang WB, Song TW, Chi YY, Xu Q, Liu C, Tang W, Xu F, Zhou JX, Yu SB, Sui HJ. Architecture of the cancellous bone in human proximal tibia based on P45 sectional plastinated specimens. Surg Radiol Anat 2021; 43:2055-2069. [PMID: 34642771 DOI: 10.1007/s00276-021-02826-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 08/26/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To reveal differences in the pattern of trabecular architecture in the epiphysis and metaphysis of the proximal tibia. METHODS The trabecular architecture of the proximal tibia was observed in 27 P45 plastinated knee specimens. RESULTS In the medial and lateral condyles, under the articular cartilage surrounded by the medial or lateral meniscus, the cancellous bone is formed by thick and dense trabecular bands, which run longitudinally in the epiphysis and then pass through the epiphyseal line to terminate on the slanted cortex of the metaphysis. In the intercondylar eminence, the trabeculae are arranged basically in a network. In the central portion of the tibial metaphysis, cancellous bone consists of fine arcuate trabeculae, which extend to the anterior and posterior cortices, respectively. These trabeculae are intersected sparsely and form trusses over the medullary cavity. Near the areas of attachment of the iliotibial tract, tibial collateral ligament, anterior and posterior cruciate ligaments, and patellar ligament, the cancellous bone is locally reinforced with patchy trabeculae, dense radiating trabeculae, or two orthotropic trabecular bands. CONCLUSION This study provides further accurate anatomical information on the trabeculae of the proximal tibia. The soft structures of knee joint, including the articular cartilage, menisci, and ligaments, and the slanted cortices of the metaphysis are important landmarks for the location of different arrangements of the cancellous architecture. The present results are beneficial for clinical diagnosis and treatment of pathologies of the knee joint, or the establishment of a finite element analysis model of the knee joint.
Collapse
Affiliation(s)
- Shi-Zhu Sun
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China
| | - Wen-Bin Jiang
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China
| | - Ting-Wei Song
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China
| | - Yan-Yan Chi
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China
| | - Qiang Xu
- Department of Radiology, The No. 967 Hospital of PLA Joint Logistics Support Force, Dalian, 116021, China
| | - Cong Liu
- Department of Radiology, The No. 967 Hospital of PLA Joint Logistics Support Force, Dalian, 116021, China
| | - Wei Tang
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China
| | - Fei Xu
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China
| | - Jia-Xin Zhou
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China
| | - Sheng-Bo Yu
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China. .,Expert Workstation, Dalian Hoffen Bio-Technique Co. Ltd., Dalian, 116052, China.
| | - Hong-Jin Sui
- Department of Anatomy, College of Basic Medicine, Dalian Medical University, Dalian, 116044, Liaoning, China. .,Dalian Hoffen Bio-Technique Co. Ltd., Dalian, 116052, China.
| |
Collapse
|
8
|
Martinez-Zelaya VR, Archilha NL, Calasans-Maia M, Farina M, Rossi AM. Trabecular architecture during the healing process of a tibial diaphysis defect. Acta Biomater 2021; 120:181-193. [PMID: 32860947 DOI: 10.1016/j.actbio.2020.08.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 08/16/2020] [Accepted: 08/19/2020] [Indexed: 01/08/2023]
Abstract
The adaptation of trabecular bone microstructure to mechanical loads has been intensively investigated. However, loading-unrelated aspects of trabecular architecture remain unclear. We used synchrotron radiation-based X-ray microtomography to study the 3D microarchitecture of newly formed trabecular tissue in a defect produced in the cortical region of the rat tibia diaphysis, in the absence (7, 14, and 21 days) or the presence (21 days) of carbonated hydroxyapatite/alginate (cHA) microspheres. This work provides the first evidence that the woven bone trabecular network, formed during the healing process, displays a well-organized 3D microarchitecture consisting of nodes with 3 (3-N), 4 (4-N) and 5 (5-N) connecting trabeculae, with a mean relative abundance of (3-N)/(4-N)/(5-N) = 66/24/7, for the analyzed periods. The measured inter-trabecular angles (ITA) distribution presented a Gaussian profile, with mean value at 115° for 3-N nodes, and 105° for 4-N nodes, close to the angles of idealized 3D regular structures (120° and 109.5°, respectively). Changes in the dispersion of ITA distribution suggested that a highly symmetric trabecular fabric organized under tensegrity principles is formed early during the bone healing process. Post-implantation, cHA disaggregated into multiple fragments (~20-400 μm), stimulating osteoconduction and bone growth toward the interior of the medullary cavity. The presence of biomaterials in bone defects affected the trabecular dimensions; however, it did not interfere with the formation of geometrical motifs with topological parameters similar to those found in the sham-defects. STATEMENT OF SIGNIFICANCE: The trabecular bone microstructure enables the tissue to meet the necessary mechanical and functional demands. However, the process of trabecular microarchitecture formation during healing, in the absence or presence of a bone graft, is not yet well understood. This work demonstrated that, from the beginning of its formation in cortical bone defects, the woven-bone trabecular network is spatially organized according to the principle of tensegrity. This microarchitecture is comprised of highly symmetric geometric motifs and is an intrinsic characteristic of trabecular growth, regardless of hierarchical scale or mechanical stimulation. The addition of a biodegradable nanostructured calcium phosphate graft did not disrupt trabecular microarchitecture; however, graft biodegradation should be controlled to optimize the reproduction of intrinsic trabecular motifs throughout the defect.
Collapse
Affiliation(s)
- Victor R Martinez-Zelaya
- Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970 Campinas, Sao Paulo, Brazil; Department of Condensed Matter, Applied Physics and Nanoscience, Brazilian Center for Research in Physics, Zip Code 22290-180 Rio de Janeiro, RJ, Brazil.
| | - Nathaly L Archilha
- Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970 Campinas, Sao Paulo, Brazil
| | - Mônica Calasans-Maia
- Oral Surgery Department, Fluminense Federal University, Zip Code 24020-140 Niterói, RJ, Brazil
| | - Marcos Farina
- Institute of Biomedical Sciences, Federal University of Rio de Janeiro, Zip Code 21941-902 Rio de Janeiro, RJ, Brazil
| | - Alexandre M Rossi
- Department of Condensed Matter, Applied Physics and Nanoscience, Brazilian Center for Research in Physics, Zip Code 22290-180 Rio de Janeiro, RJ, Brazil.
| |
Collapse
|
9
|
Pan Q, Gao C, Wang Y, Wang Y, Mao C, Wang Q, Economidou SN, Douroumis D, Wen F, Tan LP, Li H. Investigation of bone reconstruction using an attenuated immunogenicity xenogenic composite scaffold fabricated by 3D printing. Biodes Manuf 2020. [DOI: 10.1007/s42242-020-00086-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
10
|
Kirby M, Morshed AH, Gomez J, Xiao P, Hu Y, Guo XE, Wang X. Three-dimensional rendering of trabecular bone microarchitecture using a probabilistic approach. Biomech Model Mechanobiol 2020; 19:1263-1281. [DOI: 10.1007/s10237-020-01286-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Accepted: 01/03/2020] [Indexed: 11/29/2022]
|
11
|
Wu X, Ding J, Xu X, Wang X, Liu J, Jiang J, Liu Q, Kong G, Huang Z, Yang Z, Zhu Q. Ketogenic diet compromises vertebral microstructure and biomechanical characteristics in mice. J Bone Miner Metab 2019; 37:957-966. [PMID: 30968187 DOI: 10.1007/s00774-019-01002-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Accepted: 03/19/2019] [Indexed: 12/31/2022]
Abstract
Ketogenic diet (KD) compromised the microstructure of cancellous bone and the mechanical property in the appendicular bone of mice, while the effects of KD on the axial bone have not been reported. This study aimed to compare the changes in the microstructure and mechanical properties of the forth lumbar (L4) vertebra in KD and ovariectomized (OVX) mice. Forty eight-week-old female C57BL/6J mice were assigned into four groups: SD (standard diet) + Sham, SD + OVX, KD + Sham, and KD + OVX groups. L4 vertebra was scanned by micro-CT to examine the microstructure of cancellous bone, after which simulative compression tests were performed using finite element (FE) analysis. Vertebral compressive test and histological staining of the L4 and L5 vertebrae were performed to observe the biomechanical and histomorphologic changes. The KD + Sham and SD + OVX exhibited a remarkable declination in the parameters of cancellous bone compared with the SD + Sham group, while KD + OVX demonstrated the most serious bone loss in the four groups. The stiffness was significantly higher in the SD + Sham group than the other three groups, but no difference was found between the remaining groups. The trabecular parameters were significantly correlated with the stiffness. Meanwhile, the OVX + Sham and KD + OVX groups showed a significant decrease in the failure load of compressive test, while there was no difference between the KD + Sham and SD + Sham groups. These findings suggest that KD may compromise the vertebral microstructure and compressive stiffness to a similar level as OVX did, indicating adverse effects of KD on the axial bone of the mice.
Collapse
Affiliation(s)
- Xiuhua Wu
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
| | - Jianyang Ding
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
| | - Xiaolin Xu
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
| | - Xiaomeng Wang
- Department of Spinal Surgery, LongYan First Hospital, Longyan, Fujian, China
| | - Junhao Liu
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
| | - Jie Jiang
- Department of Spinal Surgery, Hongdu Hospital of TCM, Nanchang, Jiangxi, China
| | - Qi Liu
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
| | - Ganggang Kong
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
| | - Zucheng Huang
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
| | - Zhou Yang
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China
| | - Qingan Zhu
- Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, 1838 North Guangzhou Avenue, Guangzhou, China.
| |
Collapse
|
12
|
Liu F, Liu Y, Li X, Wang X, Li D, Chung S, Chen C, Lee IS. Osteogenesis of 3D printed macro-pore size biphasic calcium phosphate scaffold in rabbit calvaria. J Biomater Appl 2019; 33:1168-1177. [PMID: 30665312 DOI: 10.1177/0885328218825177] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
To investigate the osteogenesis of macro-pore sized bone scaffolds, biphasic calcium phosphate scaffolds with accurately controlled macro-pore size (0.8, 1.2, and 1.6 mm) and identical porosity of 70% were fabricated by the 3D printing technology. Eight New Zealand rabbits were selected in the present study, while four 8-mm-diameter calvarial defects were created in each rabbit to place BCP scaffolds with different macro-pore size. The harvested specimens of four and eight weeks were used to evaluate the bone forming ability by micro CT and histological examination. All 3D-printed BCP scaffolds exhibited excellent mechanical properties and had better bone-forming ability than the control at both four and eight weeks. Among them, scaffold with 0.8 mm pore size was superior for initial bone formation and maturation, resulting in the highest value of total bone formation.
Collapse
Affiliation(s)
- Fan Liu
- 1 Department of Orthodontics, School of Stomatology, China Medical University, Shenyang, China.,3 Department of Pulmonary and Critical Care Medicine, The First Affiliated Hospital, China Medical University, Shenyang, China
| | - Yi Liu
- 1 Department of Orthodontics, School of Stomatology, China Medical University, Shenyang, China
| | - Xinyu Li
- 2 Department of Tissue Engineering, School of Fundamental Sciences, China Medical University, Shenyang, China
| | - Xiaohong Wang
- 1 Department of Orthodontics, School of Stomatology, China Medical University, Shenyang, China
| | - Danni Li
- 4 Department of Medical Oncology, The First Affiliated Hospital, China Medical University, Shenyang, China
| | - SungMin Chung
- 5 Biomaterials R&D Center, GENOSS Co., Ltd., Suwon, Republic of Korea
| | - Cen Chen
- 6 College of Life Sciences, Zhejiang Sci-Tech University, Hangzhou, China
| | - In-Seop Lee
- 7 College of Materials and Textiles, Zhejiang Sci-Tech University, Hangzhou, China.,8 Institute of Natural Sciences, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|