1
|
Alukkal CR, Modiri M, Ruiz RA, Choi YJ, Lee LS. Evaluation of PFAS extraction and analysis methods for biosolids. Talanta 2025; 286:127485. [PMID: 39736209 DOI: 10.1016/j.talanta.2024.127485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2024] [Revised: 12/15/2024] [Accepted: 12/26/2024] [Indexed: 01/01/2025]
Abstract
Per- and polyfluoroalkyl substances (PFAS) in the environment is a growing concern leading to a focus on PFAS occurrence in biosolids, a byproduct of wastewater treatment processes, often applied to improve soil health. This led to the need for analytical method development for assessing PFAS in biosolids. This study compares three methods for PFAS quantitation, evaluating solvent extraction, clean-up techniques, and final injection solvents. Three biosolids examined included not stabilized, anaerobically digested, and activated sludge with long-term lagoon-stabilized solids, resulting in differing properties. One method is a methanolic extraction with ENVI-Carb clean-up (ME), modified by adding isopropanol (ME-P) to the injection vial to prevent emulsification that can occur with more complex biosolids matrices. The second method was the U.S. EPA 1633 method involving additional solid-phase extraction (SPE) and filtration while the third method was Quick Easy Cheap Effective Rugged and Safe (QuEChERS), yet to be tested on biosolids. Method performance was evaluated based on instrument precision, limit of quantitation (LOQ), and extraction recoveries. PFAS concentrations and recoveries were similar for Me-P and 1633 methods while QuEChERS performed poorly. Method 1633 exhibited better reproducibility with lower relative standard deviations but had higher LOQ values due to sample dilution. Most LOQs ranged between 0.06 and 0.3 μg/kg across methods, while recovery of spiked native PFAS ranged between 70 and 130 % in most cases. Methanol-based mobile phases resulted in better peak shape. ME-P excelled in overall cost-effectiveness showing superior extraction efficiency with fewer operational steps compared to other methods for PFAS quantitation in biosolids.
Collapse
Affiliation(s)
- Caroline Rose Alukkal
- Interdisciplinary Ecological Sciences & Engineering, Purdue University, West Lafayette, IN, 47907, USA; Department of Environmental & Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Mahsa Modiri
- Department of Agronomy, Purdue University, West Lafayette, IN, 47907, USA
| | | | - Youn Jeong Choi
- Department of Agronomy, Purdue University, West Lafayette, IN, 47907, USA
| | - Linda S Lee
- Interdisciplinary Ecological Sciences & Engineering, Purdue University, West Lafayette, IN, 47907, USA; Department of Environmental & Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA; Department of Agronomy, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
2
|
Ilieva Z, Salehi R, Aqeel H, Li Y, Suehring R, Liss SN, Hamza R. Strength under pressure: Aerobic granular sludge (AGS) dynamics in sequencing batch reactors exposed to per- and polyfluoroalkyl substances (PFAS). JOURNAL OF HAZARDOUS MATERIALS 2025; 491:137903. [PMID: 40120256 DOI: 10.1016/j.jhazmat.2025.137903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2024] [Revised: 02/25/2025] [Accepted: 03/08/2025] [Indexed: 03/25/2025]
Abstract
This study investigated the capacity of aerobic granular sludge (AGS) to remove per- and polyfluoroalkyl substances (PFAS). Over 247 days, AGS in two sequencing batch reactors (R1-CTRL and R2-PFAS) was tested with synthetic wastewater containing four representative PFAS compounds (PFPeA, PFOA, PFBS, PFDS) chosen for their diverse properties, including chain length and hydrophobicity. The PFAS-acclimated reactor (R2-PFAS) exhibited greater resilience and improved performance compared to the control (R1-CTRL). Both reactors achieved > 95 % removal of chemical oxygen demand (COD), ammonia, and phosphate, despite PFAS concentrations reaching 500 µg L-1. However, R1-CTRL experienced declines in biomass and settleability, while R2-PFAS maintained stability and a more consistent extracellular polymeric substances (EPS) profile, suggesting tolerance to PFAS. PFAS removal varied by compound. Nearly 100 % removal efficiency was achieved for PFDS, while PFPeA, PFBS, and PFOA showed variable results (- 71 % to 93 % in R1-CTRL; - 17 % to 100 % in R2-PFAS). The findings demonstrate AGS as a promising tool for PFAS removal, particularly when biomass is acclimatized during granulation. This approach could enhance wastewater treatment efficiency and effluent quality.
Collapse
Affiliation(s)
- Zanina Ilieva
- Department of Civil Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada.
| | - Reza Salehi
- Department of Civil Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | - Hussain Aqeel
- Department of Chemistry and Biology, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | - Yanan Li
- Department of Chemistry and Biology, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | - Roxana Suehring
- Department of Chemistry and Biology, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | - Steven N Liss
- Department of Chemistry and Biology, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | - Rania Hamza
- Department of Civil Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| |
Collapse
|
3
|
Chambial P, Thakur N, Kushawaha J, Kumar R. Per- and polyfluoroalkyl substances in environment and potential health impacts: Sources, remediation treatment and management, policy guidelines, destructive technologies, and techno-economic analysis. THE SCIENCE OF THE TOTAL ENVIRONMENT 2025; 969:178803. [PMID: 40020591 DOI: 10.1016/j.scitotenv.2025.178803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2024] [Revised: 01/22/2025] [Accepted: 02/07/2025] [Indexed: 03/03/2025]
Abstract
Per- and polyfluoroalkyl Substances (PFAS), also known as forever chemicals and ubiquitous persistence, pose significant public health challenges due to their potential toxicity, particularly in drinking water and soil contamination. However, PFAS occurrence and their concentrations in different environmental matrices vary globally, but factors influencing trends, transport, fate, toxicity, and interactions with co-contaminants remain largely unexplored. Therefore, this review critically examines the state-of-the-art worldwide PFAS sources, distribution, and pathways, and evaluates how PFASs are processed in wastewater treatment, generally, which causes severe problems with the quality and safety of drinking water. Importantly, the review also underscores health issues due to PFAS consumption and recent research trends on developing effective treatment strategies to manage PFAS contamination. Potential effects of PFAS were linked to urban land use and the proportion of wastewater effluent in streamflow. Besides, major emphasis was provided on challenges for conventional treatment, destructive technologies, environmental accumulation, precursor transformation, and cost-investment related to PFAS removal technologies. To combat PFAS contamination, this review proposes a framework that promotes the comprehensive identification of prevalent compounds, with a focus on their eradication through knowledge-based and targeted analysis. Additionally, it explores the ongoing debate surrounding PFAS laws and legal frameworks, offering ideas for enhancing contamination management. Lastly, this review provides a strategic plan for improving response and preparedness, serving as a foundation for addressing future environmental challenges and informing health risk assessments.
Collapse
Affiliation(s)
- Priyanka Chambial
- Department of Biosciences (UIBT), Chandigarh University, Ludhiana, Punjab 140413, India
| | - Neelam Thakur
- Department of Zoology, Sardar Patel University, Vallabh Government College, Mandi, Himachal Pradesh 175001, India.
| | - Jyoti Kushawaha
- Department of Environmental Studies, Ramanujan College, University of Delhi, New Delhi 110019, India
| | - Rakesh Kumar
- Department of Biosystems Engineering, Auburn University, Auburn, AL 36849, USA.
| |
Collapse
|
4
|
We ACE, Stickland AD, Clarke BO, Freguia S. PFAS removal through foam harvesting during wastewater aeration. JOURNAL OF HAZARDOUS MATERIALS 2025; 491:137936. [PMID: 40112432 DOI: 10.1016/j.jhazmat.2025.137936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2025] [Revised: 02/13/2025] [Accepted: 03/11/2025] [Indexed: 03/22/2025]
Abstract
Aeration in wastewater treatment plants (WWTPs) is used for removal of organic matter and nutrients. Here we show that aeration can also lead to removal of per- and polyfluoroalkyl substances (PFAS), by foam fractionation. Rising air bubbles facilitate air-liquid interfacial adsorption of PFAS and spontaneous foaming occurrence. This suggests that some modifications to conventional treatment processes that enable foam removal may be sufficient to achieve PFAS removal at WWTPs. However, high suspended solids concentrations in the mixed liquor suspension within the aerated bioreactors may complicate PFAS removal in foam fractionation, as both air bubbles and suspended biomass retain PFAS. This study explored the feasibility of foam fractionation for PFAS removal and enrichment using actual mixed liquor suspensions with typical total suspended solids concentrations and WWTP-relevant PFAS concentrations. The mechanisms involved in PFAS removal and enrichment in both aqueous and solid phases were suggested, and a mass balance analysis was performed to show PFAS distribution between the two phases. Overall, PFAS removal from the aqueous phase ranged from 70 % to 100 % for PFAS with perfluorinated carbon numbers ≥ 6, while PFAS with perfluorinated carbon numbers < 6 showed low removal of < 20 %. PFAS removal from the solid phase ranged from 20 % to 60 %, depending on the PFAS species. This study represents an ongoing effort to advance the potential implementation of foam fractionation in aerated bioreactors at WWTPs.
Collapse
Affiliation(s)
- Angel Chyi En We
- Department of Chemical Engineering, The University of Melbourne, Parkville, Victoria 3010, Australia; Australian Laboratory of Emerging Contaminants, School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Anthony D Stickland
- Department of Chemical Engineering, The University of Melbourne, Parkville, Victoria 3010, Australia
| | - Bradley O Clarke
- Australian Laboratory of Emerging Contaminants, School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Stefano Freguia
- Department of Chemical Engineering, The University of Melbourne, Parkville, Victoria 3010, Australia.
| |
Collapse
|
5
|
Peter L, Modiri‐Gharehveran M, Alvarez‐Campos O, Evanylo GK, Lee LS. PFAS fate using lysimeters during degraded soil reclamation using biosolids. JOURNAL OF ENVIRONMENTAL QUALITY 2025; 54:41-53. [PMID: 38816342 PMCID: PMC11718147 DOI: 10.1002/jeq2.20576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 05/01/2024] [Indexed: 06/01/2024]
Abstract
Carbon- and nutrient-rich biosolids are used in agriculture and land reclamation. However, per- and polyfluoroalkyl substances (PFAS) typically present in biosolids raise concerns of PFAS leaching to groundwater and plant uptake. Here, we investigated PFAS persistence and leaching from biosolids applied to a site constructed artificially to mimic degraded soils. Treatments included biosolids and biosolids blended with mulch applied at different rates to attain either one and five times the agronomic N rate for vegetable crops and a control treatment with synthetic urea and triple superphosphate fertilizer. Leachates were collected for a 2-year period from 15-cm depth zero-tension drainage lysimeters. Soils were analyzed post biosolids application. PFAS were quantified using isotope-dilution, solid-phase extraction and liquid chromatography tandem mass spectrometry. Leachate profiles exemplified an initial high total PFAS concentration, followed by a sharp decline and subsequent small fluctuations attributed to pre-existing soil conditions and rainfall patterns. Quantifiable PFAS in leachate were proportional to biosolids application rates. Short-chain perfluoroalkyl acids (CF2 < 6) were dominant in leachate, while the percentage of longer chains homologues was higher in soils. A 43% biosolids blend with mulch resulted in 21% lower PFAS leachate concentrations even with the blend application rate being 1.5 times higher than biosolids due to the blend's lower N-content. The blending effect was more pronounced for long-chain perfluoroalkyl sulfonic acids that have a greater retention by soils and the air-water interface. Biosolids blending as a pragmatic strategy for reducing PFAS leachate concentrations may aid in the sustainable beneficial reuse of biosolids.
Collapse
Affiliation(s)
- Lynda Peter
- Department of Agronomy, Ecological Sciences & Engineering Interdisciplinary Graduate ProgramPurdue UniversityWest LafayetteIndianaUSA
| | - Mahsa Modiri‐Gharehveran
- Environmental & Ecological EngineeringPurdue UniversityWest LafayetteIndianaUSA
- EA Engineering, Science, and Technology, Inc., PBCHunt ValleyMarylandUSA
| | - Odiney Alvarez‐Campos
- USAIDWashingtonDistrict of ColumbiaUSA
- School of Plant and Environmental SciencesVirginia TechBlacksburgVirginiaUSA
| | - Gregory K. Evanylo
- School of Plant and Environmental SciencesVirginia TechBlacksburgVirginiaUSA
| | - Linda S. Lee
- Department of Agronomy, Ecological Sciences & Engineering Interdisciplinary Graduate ProgramPurdue UniversityWest LafayetteIndianaUSA
- Environmental & Ecological EngineeringPurdue UniversityWest LafayetteIndianaUSA
| |
Collapse
|
6
|
Katsenovich Y, Tansel B, Soares Quinete N, Nasir Z, Ocheje JO, Manzano MM. Leaching profile of per- and polyfluoroalkyl substances (PFAS) from biosolids after thickening, anaerobic digestion, and dewatering processes, and significance of protein, phosphorus, and selected ions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 957:177777. [PMID: 39626423 DOI: 10.1016/j.scitotenv.2024.177777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2024] [Revised: 11/15/2024] [Accepted: 11/24/2024] [Indexed: 12/21/2024]
Abstract
Batch leaching experiments were conducted to evaluate the release of forty per- and polyfluoroalkyl substances (PFAS) from sludge samples collected after thickening, anaerobic digestion, and dewatering processes at two wastewater treatment plants. The South District wastewater treatment plant (SDWWTP), which receives domestic wastewater and landfill leachate from a nearby landfill, and the Central District wastewater treatment plant (CDWWTP), which receives only domestic wastewater, were selected for this study. PFAS released into the aqueous phase were analyzed by sacrificial sampling after 1, 3, 7, 14, and 30 days. Results demonstrated rapid PFAS leaching, with the highest levels detected in biosolid leachates after just one day. Distinct differences were observed in PFAS composition and concentrations between the two treatment plants. Of the forty PFAS measured, nineteen were detected, with higher concentrations identified at SDWWTP. The input of landfill leachate to SDWWTP appears to have significantly contributed to the elevated levels of specific PFAS, particularly long-chain compounds, compared to the emerging short-chain PFAS found in biosolids. In addition to PFAS analysis, the compositions of the sludge samples, including total and volatile solids, protein, phosphorus (P), iron, aluminum, calcium, and magnesium, were also assessed. Spearman correlation analyses revealed moderate to strong relationships between PFAS levels in leachate and certain sludge components. For instance, correlations between P content and PFCAs and FTCAs were moderate (R2 = 0.45-0.76). In thickener sludge leachate, strong correlations were observed for FPrPA (3:3 FTCA), PFDA, and PFTrDA with P, with R2 values of 0.60, 0.53, and 0.54, respectively. In the digested sludge, correlations were found for PFHpA, PFDA, and PFNA (R2 = 0.45-0.76). Also, for digested sludge leachate, strong correlations were found between the individual compounds PFHpA, PFHxA, PFNA, PFOA, and PFPeA (R2 = 0.60-0.88). Predominant PFAS in leachate from biosolids were identified, including PFOS, FPePA (5:3 FTCA), PFPeA, PFBA, PFHxA, N-EtFOSAA, and 6-2 FTS.
Collapse
Affiliation(s)
- Yelena Katsenovich
- Applied Research Center, Florida International University, 10555 W Flagler St, Miami, FL, 33174, USA.
| | - Berrin Tansel
- Department of Civil & Environmental Engineering, 10555 W Flagler St, Miami, FL, 33174, USA
| | - Natalia Soares Quinete
- Department of Chemistry and Biochemistry, Florida International University, 11960 SW 11th St, Miami, FL, 33199, USA; Institute of Environment, Florida International University, 11960 SW 11th St, Miami, FL, 33199, USA
| | - Zariah Nasir
- Applied Research Center, Florida International University, 10555 W Flagler St, Miami, FL, 33174, USA
| | - Joshua Omaojo Ocheje
- Department of Chemistry and Biochemistry, Florida International University, 11960 SW 11th St, Miami, FL, 33199, USA; Institute of Environment, Florida International University, 11960 SW 11th St, Miami, FL, 33199, USA
| | - Maria Mendoza Manzano
- Department of Chemistry and Biochemistry, Florida International University, 11960 SW 11th St, Miami, FL, 33199, USA
| |
Collapse
|
7
|
Mel M, Lau B, Hockaday WC. Sorption of per- and polyfluoroalkyl substances by lignin in pulp and paper wastewater. JOURNAL OF HAZARDOUS MATERIALS 2024; 480:136016. [PMID: 39405694 DOI: 10.1016/j.jhazmat.2024.136016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 09/27/2024] [Accepted: 09/29/2024] [Indexed: 12/01/2024]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are anthropogenic chemicals commonly found in the environment. PFAS pose multifaceted challenges including identifying sources and exposure pathways, detecting and quantifying their presence, characterizing their fate and transport, and assessing their risks. PFAS and fluorotelomer polymers can be found in the pulp and paper (P&P) wastewater systems, but their behavior remains poorly understood. The constituents of P&P waste include lignin hydrolysis products, hence PFAS interactions with lignin likely affect PFAS removal efforts. This study employed quantitative ultra-performance liquid chromatography triple quadrupole mass spectrometry (UPLC-MS/MS) to investigate the sorption-desorption capacity and mechanisms of PFAS interaction with lignin. PFAS with sulfonate functional groups displayed higher affinity for lignin (solid phase) based on their partitioning coefficient (Kd), while PFAS with carboxylate head groups persisted in the P&P wastewater (aqueous phase). Sorption to lignin exhibited an increase with chain length (CF2)n among compounds with the same functional group. Long-chain (C ≥ 6) PFAS demonstrated higher sorption compared to short-chain (C ≤ 5) homologs. The sorption-desorption capacities, partitioning coefficients, and kinetics of PFAS reported in this study can facilitate predictive models for PFAS and assist in the development of efficient P&P waste treatment and management.
Collapse
Affiliation(s)
- Manyiel Mel
- Department of Geosciences, Baylor University, Waco, TX 76706, United States.
| | - Boris Lau
- National Council for Air and Stream Improvement, Inc. (NCASI), Newberry, FL 32669, United States.
| | - William C Hockaday
- Department of Geosciences, Baylor University, Waco, TX 76706, United States.
| |
Collapse
|
8
|
Saliu TD, Liu M, Habimana E, Fontaine J, Dinh QT, Sauvé S. PFAS profiles in biosolids, composts, and chemical fertilizers intended for agricultural land application in Quebec (Canada). JOURNAL OF HAZARDOUS MATERIALS 2024; 480:136170. [PMID: 39426151 DOI: 10.1016/j.jhazmat.2024.136170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2024] [Revised: 10/03/2024] [Accepted: 10/12/2024] [Indexed: 10/21/2024]
Abstract
Biosolids, sewage sludge, and composts are applied to agricultural land for nutrient recovery and soil organic matter replenishment, aligning with sustainable development goals. However, they may contain per- and polyfluoroalkyl substances (PFAS) that can enter the food chain through plant bioaccumulation and leaching into the groundwater. This study analyzed 80 PFAS compounds in sewage sludge, biosolids, commercial composts, and chemical fertilizers in Quebec, Canada, using UHPLC-HRMS (Orbitrap Q-Exactive). PFAS concentrations ranged from 18 to 59 µg/kg in commercial composts, 9.8 to 213 µg/kg in pulp and paper sludge, 15 to 705 µg/kg in sewage sludge, 12 to 1310 µg/kg in biosolids, and 14.6 µg/kg on average in biosolids ash. Dominant PFAS classes included diPAPs, sulfonamides, PFCAs, and PFSAs. High diPAPs concentrations indicated widespread use in domestic, commercial, or industrial applications. This study also observed a negligible correlation between soil organic carbon and PFAS concentration in the biowastes signifying a stronger influence due to different WWTP configurations, the quality of the wastewater inputs and other medium's properties that could affect PFAS partitioning to the biowastes. Environmental assessments showed PFAS loads of up to 30 µg/kg soil from a single application, within some regulatory limits. However, repeated applications could lead to PFAS accumulation in soil, posing risks to crops and groundwater.
Collapse
Affiliation(s)
- Toyin Dunsin Saliu
- Department of Chemistry, Université de Montréal, Montreal, Quebec H3C 3J7, Canada
| | - Min Liu
- Department of Chemistry, Université de Montréal, Montreal, Quebec H3C 3J7, Canada
| | - Emile Habimana
- Department of Chemistry, Université de Montréal, Montreal, Quebec H3C 3J7, Canada
| | - Justine Fontaine
- Department of Chemistry, Université de Montréal, Montreal, Quebec H3C 3J7, Canada
| | - Quoc Tuc Dinh
- Department of Chemistry, Université de Montréal, Montreal, Quebec H3C 3J7, Canada
| | - Sébastien Sauvé
- Department of Chemistry, Université de Montréal, Montreal, Quebec H3C 3J7, Canada.
| |
Collapse
|
9
|
Bayode AA, Emmanuel SS, Akinyemi AO, Ore OT, Akpotu SO, Koko DT, Momodu DE, López-Maldonado EA. Innovative techniques for combating a common enemy forever chemicals: A comprehensive approach to mitigating per- and polyfluoroalkyl substances (PFAS) contamination. ENVIRONMENTAL RESEARCH 2024; 261:119719. [PMID: 39098711 DOI: 10.1016/j.envres.2024.119719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 07/24/2024] [Accepted: 07/31/2024] [Indexed: 08/06/2024]
Abstract
The pervasive presence of per and polyfluoroalkyl substances (PFAS), commonly referred to as "forever chemicals," in water systems poses a significant threat to both the environment and public health. PFAS are persistent organic pollutants that are incredibly resistant to degradation and have a tendency to accumulate in the environment, resulting in long-term contamination issues. This comprehensive review delves into the primary impacts of PFAS on both the environment and human health while also delving into advanced techniques aimed at addressing these concerns. The focus is on exploring the efficacy, practicality, and sustainability of these methods. The review outlines several key methods, such as advanced oxidation processes, novel materials adsorption, bioremediation, membrane filtration, and in-situ chemical oxidation, and evaluates their effectiveness in addressing PFAS contamination. By conducting a comparative analysis of these techniques, the study aims to provide a thorough understanding of current PFAS remediation technologies, as well as offer insights into integrated approaches for managing these persistent pollutants effectively. While acknowledging the high efficiency of adsorption and membrane filtration in reducing persistent organic pollutants due to their relatively low cost, versatility, and wide applicability, the review suggests that the integration of these methods could result in an overall enhancement of removal performance. Additionally, the study emphasizes the need for researcher attention in key areas and underscores the necessity of collaboration between researchers, industry, and regulatory authorities to address this complex challenge.
Collapse
Affiliation(s)
- Ajibola A Bayode
- College of Chemical Engineering, Sichuan University of Science and Engineering, Zigong, 643000, China; Department of Chemical Sciences, Faculty of Natural Sciences, Redeemer's University, P.M.B. 230, 232101, Ede, Nigeria.
| | - Stephen Sunday Emmanuel
- Department of Industrial Chemistry, Faculty of Physical Sciences, University of Ilorin, P. M. B. 1515, Ilorin, Nigeria.
| | - Amos O Akinyemi
- Department of Toxicology & Cancer Biology, University of Kentucky, Lexington, KY, 40536, USA
| | - Odunayo T Ore
- Department of Chemical Sciences, Achievers University, P.M.B. 1030, Owo, Nigeria
| | - Samson O Akpotu
- Department of Chemistry, Vaal University of Technology, Vanderbijlpark, 1900, Gauteng, South Africa
| | - Daniel T Koko
- Department of Chemical Sciences, Faculty of Natural Sciences, Redeemer's University, P.M.B. 230, 232101, Ede, Nigeria
| | - David E Momodu
- Department of Chemical Sciences, Faculty of Natural Sciences, Redeemer's University, P.M.B. 230, 232101, Ede, Nigeria
| | | |
Collapse
|
10
|
We ACE, Stickland AD, Clarke BO, Freguia S. Analysis of wastewater treatment plant data identifies the drivers of PFAS enrichment in foams. WATER RESEARCH 2024; 266:122397. [PMID: 39288725 DOI: 10.1016/j.watres.2024.122397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 08/08/2024] [Accepted: 09/04/2024] [Indexed: 09/19/2024]
Abstract
The concept of incorporating foam fractionation in aerated bioreactors at wastewater treatment plants (WWTPs) for the removal of per- and polyfluoroalkyl substances (PFAS) has recently been proposed. The extent of PFAS enrichment in aerated bioreactors' foams, as indicated by enrichment factors (EFs), has been observed to vary widely. Laboratory evidence has shown that factors affecting PFAS enrichment in foams include conductivity, surfactant concentrations and initial PFAS concentrations. However, real wastewaters are complex heterogenous matrices with physical, chemical and biological characteristics potentially contributing to the phenomenon of PFAS partitioning into foams. In this study, we characterised mixed liquor suspensions, including conductivity, filament content, aqueous PFAS concentrations, surface tension and total suspended solids concentrations (TSS) as well as foams, including bubble size and half-life. We used statistical tools - linear mixed-effects model - to establish relationships between PFAS enrichment in aerated bioreactor foams and the examined characteristics. We found that some of the examined characteristics, specifically filament content, surface tension and TSS concentrations measured in mixed liquor suspension and foam half-life, are negatively and significantly associated with the enrichment of longer chain PFAS (with perfluorinated carbon number ≥ 6). Of these, filament content is the important determinant of PFAS enrichment, potentially leading to an increase in, for example, perfluorooctanoic acid (PFOA) EF from 3 to 100 between typical filamentous and non-filamentous suspended biomass. However, enrichment of shorter chain PFAS (with perfluorinated carbon number ≤ 5) is negligible and is not affected by the characteristics that were measured. The findings of our study may serve as valuable information for the implementation of foam fractionation at WWTPs by elucidating the drivers that contribute to the enrichment of longer chain PFAS, under conditions typically found at WWTPs.
Collapse
Affiliation(s)
- Angel Chyi En We
- Department of Chemical Engineering, The University of Melbourne, Building 165, Chemical Engineering 1, Parkville VIC 3010, Australia; Australian Laboratory for Emerging Contaminants, School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Anthony D Stickland
- Department of Chemical Engineering, The University of Melbourne, Building 165, Chemical Engineering 1, Parkville VIC 3010, Australia
| | - Bradley O Clarke
- Australian Laboratory for Emerging Contaminants, School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Stefano Freguia
- Department of Chemical Engineering, The University of Melbourne, Building 165, Chemical Engineering 1, Parkville VIC 3010, Australia.
| |
Collapse
|
11
|
Hort HM, Robinson CE, Sawyer AH, Li Y, Cardoso R, Lee SA, Roff D, Adamson DT, Newell CJ. Conceptualizing Controlling Factors for PFAS Salting Out in Groundwater Discharge Zones Along Sandy Beaches. GROUND WATER 2024; 62:860-875. [PMID: 38940354 DOI: 10.1111/gwat.13428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 02/18/2024] [Accepted: 06/04/2024] [Indexed: 06/29/2024]
Abstract
Understanding fate and transport processes for per- and poly-fluoroalkyl substances (PFAS) is critical for managing impacted sites. "PFAS Salting Out" in groundwater, defined herein, is an understudied process where PFAS in fresh groundwater mixes with saline groundwater near marine shorelines, which increases sorption of PFAS to aquifer solids. While sorption reduces PFAS mass discharge to marine surface water, the fraction that sorbs to beach sediments may be mobilized under future salinity changes. The objective of this study was to conceptually explore the potential for PFAS Salting Out in sandy beach environments and to perform a preliminary broad-scale characterization of sandy shoreline areas in the continental U.S. While no site-specific PFAS data were collected, our conceptual approach involved developing a multivariate regression model that assessed how tidal amplitude and freshwater submarine groundwater discharge affect the mixing of fresh and saline groundwater in sandy coastal aquifers. We then applied this model to 143 U.S. shoreline areas with sandy beaches (21% of total beaches in the USA), indirectly mapping potential salinity increases in shallow freshwater PFAS plumes as low (<10 ppt), medium (10-20 ppt), or high (>20 ppt) along groundwater flow paths before reaching the ocean. Higher potential salinity increases were observed in West Coast bays and the North Atlantic coastline, due to the combination of moderate to large tides and large fresh groundwater discharge rates, while lower increases occurred along the Gulf of Mexico and the southern Florida Atlantic coast. The salinity increases were used to estimate potential perfluorooctane sulfonic acid (PFOS) sorption in groundwater due to salting out processes. Low-category shorelines may see a 1- to 2.5-fold increase in sorption of PFOS, medium-category a 2.0- to 6.4-fold increase, and high-category a 3.8- to 25-fold increase in PFOS sorption. The analysis presented provides a first critical step in developing a large-scale approach to classify the PFAS Salting Out potential along shorelines and the limitations of the approach adopted highlights important areas for further research.
Collapse
Affiliation(s)
- Hiroko M Hort
- GSI Environmental Inc, 7595 Irvine Center Dr, Suite 250, Irvine, CA, USA
| | - Clare E Robinson
- Department of Civil and Environmental Engineering, Western University, London, ON, Canada
| | - Audrey H Sawyer
- School of Earth Sciences, The Ohio State University, Columbus, OH
| | - Yue Li
- GSI Environmental Inc., Houston, TX, USA
| | - Rebecca Cardoso
- Navy Facilities Engineering Systems Command Southwest, San Diego, CA, USA
| | - Sophia A Lee
- Navy Facilities Engineering Systems Command Southwest, San Diego, CA, USA
| | | | | | | |
Collapse
|
12
|
Ohoro CR, Amaku JF, Conradie J, Olisah C, Akpomie KG, Malloum A, Akpotu SO, Adegoke KA, Okeke ES, Omotola EO. Effect of physicochemical parameters on the occurrence of per- and polyfluoroalkyl substances (PFAS) in aquatic environment. MARINE POLLUTION BULLETIN 2024; 208:117040. [PMID: 39366060 DOI: 10.1016/j.marpolbul.2024.117040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2024] [Revised: 09/13/2024] [Accepted: 09/21/2024] [Indexed: 10/06/2024]
Abstract
Perfluoroalkyl substances (PFAS) and their distribution in aquatic environments have been studied extensively, but more information is needed to link these occurrences to their physicochemical characteristics. Understanding how these parameters influence PFAS can help predict their fate, mobility, and occurrences in water. This study reviewed the influence of physicochemical parameters on the occurrences of PFAS in aquatic environment using the relevant keywords to retrieve articles from databases spanning mostly between 2017 and 2024. The result suggests that high pH, turbidity, and dissolved oxygen, give high concentration of PFAS, while high electrical conductivity, temperature and salinity give low PFAS concentration in the water. Therefore, monitoring and safeguarding the aquatic bodies for human and environmental safety is imperative. Future studies should include the effects of the physicochemical properties on PFAS occurrences in the natural environment and focus on an organism's distinctive characteristics to comprehend the bioaccumulation and biomagnification of PFAS in them and environmental matrices.
Collapse
Affiliation(s)
- Chinemerem Ruth Ohoro
- Water Research Group, Unit for Environmental Sciences and Management, North-West University, 11 Hoffman St, Potchefstroom 2520, South Africa.
| | - James F Amaku
- Department of Chemistry, Michael Okpara University of Agriculture, Umudike, Nigeria; Environmental Fate of Chemicals and Remediation Laboratory, Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, Gauteng, South Africa
| | - Jeanet Conradie
- Department of Chemistry, University of the Free State, Bloemfontein 9300, South Africa
| | - Chijioke Olisah
- Institute for Coastal and Marine Research (CMR), Nelson Mandela University, P.O. Box 77000, Gqeberha 6031, South Africa; Research Centre for Toxic Compounds in the Environment (RECETOX), Faculty of Science, Masaryk University, Kamenice 5/753, 625 00 Brno, Czech Republic
| | - Kovo G Akpomie
- Department of Chemistry, University of the Free State, Bloemfontein 9300, South Africa; Department of Pure & Industrial Chemistry, University of Nigeria, Nsukka, Nigeria
| | - Alhadji Malloum
- Department of Chemistry, University of the Free State, Bloemfontein 9300, South Africa; Department of Physics, Faculty of Science, University of Maroua, Maroua, Cameroon
| | - Samson O Akpotu
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | - Kayode A Adegoke
- Department of Industrial Chemistry, First Technical University, Ibadan, Nigeria
| | - Emmanuel Sunday Okeke
- Department of Biochemistry, Faculty of Biological Sciences, University of Nigeria, Nsukka, Enugu State, Nigeria; Natural Science Unit, School of General Studies, University of Nigeria, Nsukka, Enugu State, Nigeria; Institute of Environmental Health and Ecological Security, School of the Environment and Safety, Engineering, Jiangsu University, Zhenjiang 212013, PR China
| | - Elizabeth O Omotola
- Department of Chemical Sciences, Tai Solarin University of Education, Ijebu Ode PMB 2118, Ogun State, Nigeria
| |
Collapse
|
13
|
Gong H, Hu J, Rui X, Wang Y, Zhu N. Drivers of change behind the spatial distribution and fate of typical trace organic pollutants in fresh waste leachate across China. WATER RESEARCH 2024; 263:122170. [PMID: 39096808 DOI: 10.1016/j.watres.2024.122170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 06/15/2024] [Accepted: 07/27/2024] [Indexed: 08/05/2024]
Abstract
There have been growing concerns regarding the health and environmental impacts of trace organic pollutants (TOPs). However, fresh leachate from municipal solid waste (MSW) has been overlooked as a potential reservoir of TOPs. Therefore, we investigated 90 legacy and emerging TOPs in fresh leachate from 14 provinces and municipalities in China. Additionally, the fate and final discharge impacts of TOPs in 14 leachate treatment systems were analyzed. The results revealed that the detection rate of 90 TOPs was over 50 % in all samples. Notably, polychlorinated biphenyls, banned for 40 years, were frequently detected in fresh leachate. The concentration of pseudo-persistent TOPs (105-107 ng/L) is significantly higher than that of persistent TOPs (102-104 ng/L). Spatial distribution patterns of TOPs in fresh leachate suggest that economy, population, climate, and policies impact TOPs discharge from MSW. For example, economically developed and densely populated areas displayed higher TOPs concentrations, whereas warmer climates facilitate TOPs leaching from MSW. We confirmed that waste classification policies were a key driver of the decline in multiple TOPs in leachate. Mass balance analysis shows that the final effluent and sludge from current dominant leachate treatment systems contain refractory TOPs, especially perfluoroalkyl acids, which must be prioritized for control. This paper was the first comprehensive investigation of multiple TOPs in fresh leachate at a large geographic scale. The factors affecting the occurrence, spatial distribution, and fate of TOPs in fresh leachate were revealed. It provides a valuable reference for the establishment of policies for the management of TOPs in MSW and the associated leachate.
Collapse
Affiliation(s)
- Huabo Gong
- School of Environmental Science & Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China; Shanghai Engineering Research Center of Solid Waste Treatment and Resource Recovery, School of Environmental Science & Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Jinwen Hu
- School of Environmental Science & Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China; Shanghai Engineering Research Center of Solid Waste Treatment and Resource Recovery, School of Environmental Science & Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Xuan Rui
- School of Environmental Science & Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China; Shanghai Engineering Research Center of Solid Waste Treatment and Resource Recovery, School of Environmental Science & Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Yawei Wang
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China
| | - Nanwen Zhu
- School of Environmental Science & Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China; Shanghai Engineering Research Center of Solid Waste Treatment and Resource Recovery, School of Environmental Science & Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China.
| |
Collapse
|
14
|
Deligiannis M, Gkalipidou E, Gatidou G, Kostakis MG, Triantafyllos Gerokonstantis D, Arvaniti OS, Thomaidis NS, Vyrides I, Hale SE, Peter Arp H, Fountoulakis MS, Stasinakis AS. Study on the fate of per- and polyfluoroalkyl substances during thermophilic anaerobic digestion of sewage sludge and the role of granular activated carbon addition. BIORESOURCE TECHNOLOGY 2024; 406:131013. [PMID: 38901748 DOI: 10.1016/j.biortech.2024.131013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Revised: 06/11/2024] [Accepted: 06/18/2024] [Indexed: 06/22/2024]
Abstract
Limited information is available on the removal of per- and polyfluoroalkyl substances (PFAS) in anaerobic digestion (AD). Τhe fate of six PFAS was studied in thermophilic bioreactors in the presence of granular activated carbon (GAC) and voltage application. Reactors with GAC exhibited lower concentrations of volatile fatty acids and higher methane production compared to those with and without the application of voltage. Analysis of PFAS in dissolved and solid phase showed that their distribution was dependent on perfluorocarbon chain length and functional group. Mass balances showed that PFAS were not removed during conventional AD or after applying voltage; however, significant removal (up to 61 ± 8 %) was observed in bioreactors with GAC for perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorooctane sulfonate (PFOS). Biomass characterization showed that in these bioreactors, the relative abundance of Acinetobacter and Pseudomonas was higher, indicating their potential role in PFAS biotransformation.
Collapse
Affiliation(s)
| | - Evdokia Gkalipidou
- Department of Environment, University of the Aegean, Mytilene 81100, Greece
| | - Georgia Gatidou
- Department of Environment, University of the Aegean, Mytilene 81100, Greece
| | - Marios G Kostakis
- Department of Chemistry, National and Kapodistrian University of Athens, Athens 15771, Greece
| | | | - Olga S Arvaniti
- Department of Agricultural Development, Agrofood and Management of Natural Resources, National and Kapodistrian University of Athens, Psachna 34400, Greece
| | - Nikolaos S Thomaidis
- Department of Chemistry, National and Kapodistrian University of Athens, Athens 15771, Greece
| | - Ioannis Vyrides
- Department of Chemical Engineering, Cyprus University of Technology, 95 Eirinis Str., Limassol 3603, Cyprus
| | - Sarah E Hale
- TZW: DVGW-Technologiezentrum Wasser, Karlsruher Str. 84, 76139, Karlsruhe, Germany
| | - Hans Peter Arp
- Norwegian Geotechnical Institute (NGI), Ullevål Stadion, P.O. Box 3930, 0806, Oslo, Norway; Norwegian University of Science and Technology (NTNU), NO-7491 Trondheim, Norway
| | | | | |
Collapse
|
15
|
Behnami A, Zoroufchi Benis K, Pourakbar M, Yeganeh M, Esrafili A, Gholami M. Biosolids, an important route for transporting poly- and perfluoroalkyl substances from wastewater treatment plants into the environment: A systematic review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 925:171559. [PMID: 38458438 DOI: 10.1016/j.scitotenv.2024.171559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 02/21/2024] [Accepted: 03/05/2024] [Indexed: 03/10/2024]
Abstract
The pervasive presence of poly- and perfluoroalkyl substances (PFAS) in diverse products has led to their introduction into wastewater systems, making wastewater treatment plants (WWTPs) significant PFAS contributors to the environment. Despite WWTPs' efforts to mitigate PFAS impact through physicochemical and biological means, concerns persist regarding PFAS retention in generated biosolids. While numerous review studies have explored the fate of these compounds within WWTPs, no study has critically reviewed their presence, transformation mechanisms, and partitioning within the sludge. Therefore, the current study has been specifically designed to investigate these aspects. Studies show variations in PFAS concentrations across WWTPs, highlighting the importance of aqueous-to-solid partitioning, with sludge from PFOS and PFOA-rich wastewater showing higher concentrations. Research suggests biological mechanisms such as cytochrome P450 monooxygenase, transamine metabolism, and beta-oxidation are involved in PFAS biotransformation, though the effects of precursor changes require further study. Carbon chain length significantly affects PFAS partitioning, with longer chains leading to greater adsorption in sludge. The wastewater's organic and inorganic content is crucial for PFAS adsorption; for instance, higher sludge protein content and divalent cations like calcium and magnesium promote adsorption, while monovalent cations like sodium impede it. In conclusion, these discoveries shed light on the complex interactions among factors affecting PFAS behavior in biosolids. They underscore the necessity for thorough considerations in managing PFAS presence and its impact on environmental systems.
Collapse
Affiliation(s)
- Ali Behnami
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran; Research Center for Environmental Health Technology, Iran University of Medical Sciences, Tehran, Iran
| | - Khaled Zoroufchi Benis
- Department of Process Engineering and Applied Science, Dalhousie University, Halifax, NS, Canada
| | - Mojtaba Pourakbar
- Department of Environmental Health Engineering, Maragheh University of Medical Sciences, Maragheh, Iran; Health and Environment Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mojtaba Yeganeh
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran; Research Center for Environmental Health Technology, Iran University of Medical Sciences, Tehran, Iran
| | - Ali Esrafili
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran; Research Center for Environmental Health Technology, Iran University of Medical Sciences, Tehran, Iran.
| | - Mitra Gholami
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran; Research Center for Environmental Health Technology, Iran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
16
|
We ACE, Stickland AD, Clarke BO, Freguia S. The role of suspended biomass in PFAS enrichment in wastewater treatment foams. WATER RESEARCH 2024; 254:121349. [PMID: 38401288 DOI: 10.1016/j.watres.2024.121349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 02/08/2024] [Accepted: 02/20/2024] [Indexed: 02/26/2024]
Abstract
Foaming in aerated bioreactors at wastewater treatment plants (WWTPs) has been identified as an operational issue for decades. However, the affinity of per- and polyfluoroalkyl substances (PFAS) for air-liquid interfaces suggests that foam harvesting has the potential to become a sustainable method for PFAS removal from sewage. Aerated bioreactors' foams are considered three-phase systems, comprising air, aqueous and solid components, the latter consisting of activated sludge biomass. To achieve a comprehensive understanding of the capability of aerated bioreactors' foams to enrich PFAS, we analysed PFAS concentrations from WWTPs in both the solid and aqueous phases of the collapsed foams (foamate) and underlying bulk mixed liquors. Our findings show that PFAS enrichment occurs not only in the aqueous phase but also in the solid phase of the foamate. This suggests that previous field studies that only analysed the aqueous phase may have underestimated the capability of the aerated bioreactors' foams to enrich PFAS. Fractions of PFOA and PFOS sorbed to the solid phase of the foamate can be as high as 60 % and 95 %, respectively. Our findings highlight the importance of implementing effective foamate management strategies that consider both the aqueous and solid phases.
Collapse
Affiliation(s)
- Angel Chyi En We
- Department of Chemical Engineering, The University of Melbourne, Parkville, Victoria, 3010, Australia; Australian Laboratory for Emerging Contaminants, School of Chemistry, The University of Melbourne, Victoria, 3010, Australia
| | - Anthony D Stickland
- Department of Chemical Engineering, The University of Melbourne, Parkville, Victoria, 3010, Australia
| | - Bradley O Clarke
- Australian Laboratory for Emerging Contaminants, School of Chemistry, The University of Melbourne, Victoria, 3010, Australia
| | - Stefano Freguia
- Department of Chemical Engineering, The University of Melbourne, Parkville, Victoria, 3010, Australia.
| |
Collapse
|
17
|
Iannone A, Carriera F, Passarella S, Fratianni A, Avino P. There's Something in What We Eat: An Overview on the Extraction Techniques and Chromatographic Analysis for PFAS Identification in Agri-Food Products. Foods 2024; 13:1085. [PMID: 38611389 PMCID: PMC11011820 DOI: 10.3390/foods13071085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 03/29/2024] [Accepted: 03/30/2024] [Indexed: 04/14/2024] Open
Abstract
Per- and polyfluorinated alkyl substances (PFASs) are a group of anthropogenic chemicals used in a range of industrial processes and consumer products. Recently, their ubiquitous presence in the environment as well as their toxicological effects in humans have gained relevant attention. Although the occurrence of PFASs is widely investigated in scientific community, the standardization of analytical method for all matrices still remains an important issue. In this review, we discussed extraction and detection methods in depth to evaluate the best procedures of PFAS identification in terms of analytical parameters (e.g., limits of detection (LODs), limits of quantification (LOQs), recoveries). Extraction approaches based on liquid-liquid extraction (LLE), alkaline digestion, and solid phase extraction (SPE), followed by liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) analysis are the main analytical methods applied in the literature. The results showed detectable recoveries of PFOA and PFOS in meat, milk, vegetables, eggs products (90.6-101.2% and of 89.2-98.4%), and fish (96-108%). Furthermore, the low LOD and LOQ values obtained for meat (0.00592-0.01907 ng g-1; 0.050 ng g-1), milk (0.003-0.009 ng g-1; 0.010-0.027 ng g-1), fruit (0.002-0.009 ng g-1; 0.006-0.024 ng g-1), and fish (0.00369-0.017.33 ng g-1; 0.05 ng g-1) also confirmed the effectiveness of the recent quick, easy, cheap, effective, rugged, and safe method (QuEChERS) for simple, speedy, and sensitive ultra-trace PFAS analysis.
Collapse
Affiliation(s)
- Alessia Iannone
- Department of Agriculture, Environmental and Food Sciences, University of Molise, Via De Sanctis, IT-86100 Campobasso, Italy; (A.I.); (F.C.); (S.P.); (A.F.)
| | - Fabiana Carriera
- Department of Agriculture, Environmental and Food Sciences, University of Molise, Via De Sanctis, IT-86100 Campobasso, Italy; (A.I.); (F.C.); (S.P.); (A.F.)
| | - Sergio Passarella
- Department of Agriculture, Environmental and Food Sciences, University of Molise, Via De Sanctis, IT-86100 Campobasso, Italy; (A.I.); (F.C.); (S.P.); (A.F.)
| | - Alessandra Fratianni
- Department of Agriculture, Environmental and Food Sciences, University of Molise, Via De Sanctis, IT-86100 Campobasso, Italy; (A.I.); (F.C.); (S.P.); (A.F.)
| | - Pasquale Avino
- Department of Agriculture, Environmental and Food Sciences, University of Molise, Via De Sanctis, IT-86100 Campobasso, Italy; (A.I.); (F.C.); (S.P.); (A.F.)
- Institute of Atmospheric Pollution Research, Division of Rome, c/o Ministry of Environment and Energy Security, Via Cristoforo Colombo 44, IT-00147 Rome, Italy
| |
Collapse
|
18
|
Gewurtz SB, Auyeung AS, De Silva AO, Teslic S, Smyth SA. Per- and polyfluoroalkyl substances (PFAS) in Canadian municipal wastewater and biosolids: Recent patterns and time trends 2009 to 2021. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:168638. [PMID: 37984658 DOI: 10.1016/j.scitotenv.2023.168638] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 11/09/2023] [Accepted: 11/14/2023] [Indexed: 11/22/2023]
Abstract
The concentrations of per- and polyfluoroalkyl substances (PFAS) were determined in raw influent, final effluent, and treated biosolids at Canadian wastewater treatment plants (WWTPs) to evaluate the fate of PFAS through liquid and solids trains of typical treatment process types used in Canada and to assess time trends of PFAS in wastewater between 2009 and 2021. Data for 42 PFAS in samples collected from 27 WWTP across Canada were used to assess current concentrations and 48 WWTPs were included in the time trends analysis. Although regulated and phased-out of production by industry since the early 2000s and late 2000s/early2010s, respectively, perfluorooctanesulfonate (PFOS), perfluorooctanoate (PFOA), and other long-chain PFAS continue to be widely detected in Canadian wastewater and biosolids. Short-chain PFAS that are not currently regulated in Canada were also widely detected. In general, elevated concentrations of several PFAS were observed at WWTPs that receive landfill leachate. Except for PFOS, concentrations of long-chain perfluoroalkyl carboxylates (PFCAs) and perfluoroalkane sulfonates (PFSAs) generally decreased over time in influent, effluent, and biosolids, which is attributable to industrial production phase-outs and regulations. Concentrations of PFOS did not decrease over time in wastewater media. This indicates that regulatory action and industrial phase-outs of PFOS are slow to be reflected in wastewater. Concentrations of short-chain PFCAs in wastewater influent and effluent consistently increased between 2009 and 2021, which reflect the use of short-chain PFAS as replacements for phased-out and regulated longer-chained PFAS. Short-chain PFAS were infrequently detected in biosolids. Continued periodic monitoring of PFAS in wastewater matrices in Canada and throughout the world is recommended to track the effectiveness of regulatory actions, particularly activities to address the broad class of PFAS.
Collapse
Affiliation(s)
- Sarah B Gewurtz
- Science and Technology Branch, Environment and Climate Change Canada, Burlington, Ontario L7S 1A1, Canada
| | - Alexandra S Auyeung
- Science and Technology Branch, Environment and Climate Change Canada, Burlington, Ontario L7S 1A1, Canada
| | - Amila O De Silva
- Science and Technology Branch, Environment and Climate Change Canada, Burlington, Ontario L7S 1A1, Canada
| | - Steven Teslic
- Science and Technology Branch, Environment and Climate Change Canada, Burlington, Ontario L7S 1A1, Canada
| | - Shirley Anne Smyth
- Science and Technology Branch, Environment and Climate Change Canada, Burlington, Ontario L7S 1A1, Canada.
| |
Collapse
|
19
|
Choi G, Kan E. Effects of perfluorooctanoic acid and perfluorooctane sulfonic acid on microbial community structure during anaerobic digestion. BIORESOURCE TECHNOLOGY 2024; 393:129999. [PMID: 37980946 DOI: 10.1016/j.biortech.2023.129999] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 11/07/2023] [Accepted: 11/07/2023] [Indexed: 11/21/2023]
Abstract
Per- and polyfluoroalkyl substances (PFASs) are recalcitrant organic pollutants, which accumulate widely in aquatic and solid matrices. Anaerobic digestion (AD) is one of possible options to manage organic wastes containing PFASs, however, the impacts of different types of PFAS on AD remains unclear. This study aimed to critically investigate the effects of two representative PFAS compounds, i.e., perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS), on the AD performance and microbial community structure. 100 mg/L of both PFOA and PFOS considerably inhibited the AD performance and changed the microbial community structure. Especially, PFOA was more toxic to bacterial and archaeal activity than PFOS, which was reflected in AD performance. In addition, the sulfonic acid group in PFOS affected the changes in microbial community structure by inducing abundant sulfate reducing bacteria (i.e., Desulfobacterota). This study provides a significant reference to the response of AD system on different PFAS types and dosage.
Collapse
Affiliation(s)
- Gyucheol Choi
- Department of Biological and Agricultural Engineering & Texas A&M AgriLife Research Center' Texas A&M University, TX 77843, USA
| | - Eunsung Kan
- Department of Biological and Agricultural Engineering & Texas A&M AgriLife Research Center' Texas A&M University, TX 77843, USA; Department of Wildlife, Sustainability, and Ecosystem Sciences, Tarleton State University, TX 76401, USA.
| |
Collapse
|
20
|
Ilieva Z, Hamza RA, Suehring R. The significance of fluorinated compound chain length, treatment technology, and influent composition on per- and polyfluoroalkyl substances removal in worldwide wastewater treatment plants. INTEGRATED ENVIRONMENTAL ASSESSMENT AND MANAGEMENT 2024; 20:59-69. [PMID: 37096563 DOI: 10.1002/ieam.4778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 04/12/2023] [Accepted: 04/19/2023] [Indexed: 05/03/2023]
Abstract
Wastewater treatment plants (WWTPs) are deemed major conveyors and point sources of per- and polyfluoroalkyl substances (PFAS) to the environment. This statistical meta-analysis of existing literature from the past 15 years focused on the significance of treatment type for PFAS removal efficiencies and the influence of PFAS sources (domestic vs. industrial) on their removal. Different sampling events, WWTPs across the world, different treatment technologies, configurations, and processes, as well as different PFAS classes and compounds were considered. This study evaluated 13 PFAS analyzed predominantly in 161 WWTPs across the world. The statistical test results revealed that these 13 frequently detected and reported PFAS can be divided into four groups based on their behavior during wastewater treatment, namely (1) C6-10 perfluorocarboxylic acids (PFCAs), (2) C4,5,11,12 PFCAs, (3) C4,6,8 perfluoroalkane sulfonic acids (PFSAs), and (4) C10 PFSA. In this study, biological treatments such as (1) membrane bioreactors, (2) combination of two or more biological treatments, and (3) biofilm processes revealed the highest PFAS removals, although the addition of a tertiary treatment actually had a nonbeneficial effect on PFAS removal. Moreover, a strong statistical correlation was observed between industrial wastewater sources and the presence of high influent PFAS concentrations in the receiving WWTPs. This indicates that industrial sources were the main contributors of the PFAS load in the analyzed WWTPs. Integr Environ Assess Manag 2024;20:59-69. © 2023 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals LLC on behalf of Society of Environmental Toxicology & Chemistry (SETAC).
Collapse
Affiliation(s)
- Zanina Ilieva
- Department of Civil Engineering, Toronto Metropolitan University, Toronto, Ontario, Canada
| | - Rania A Hamza
- Department of Civil Engineering, Toronto Metropolitan University, Toronto, Ontario, Canada
| | - Roxana Suehring
- Department of Chemistry and Biology, Toronto Metropolitan University, Toronto, Ontario, Canada
| |
Collapse
|
21
|
Ilieva Z, Hania P, Suehring R, Gilbride K, Hamza R. Impact of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) on secondary sludge microorganisms: removal, potential toxicity, and their implications on existing wastewater treatment regulations in Canada. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2023; 25:1604-1614. [PMID: 37674406 DOI: 10.1039/d3em00202k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
Perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) are two of the most commonly researched per- and polyfluoroalkyl substances (PFAS). Globally, many long-chain PFAS compounds including PFOS and PFOA are highly regulated and, in some countries, PFAS use in commercial products is strictly prohibited. Despite the legal regulation of these 'forever chemicals' under the Canadian Environmental Protection Act, PFOA and PFOS compounds are still found in high concentrations in discharges from wastewater treatment plants, both from liquid and sludge streams. Yet, their potential impact on wastewater treatment effectiveness remains poorly understood. The findings of this research show that: (1) PFOS and PFOA might be hindering the overall outcome treatment performance - calling into question the efficacy of Canada's existing wastewater treatment regulatory standard (Wastewater Systems Effluent Regulations, SOR/2012-139), and (2) specific microorganisms from the Thiobacillus and Pseudomonas genera seem capable of adsorbing PFOS and PFOA onto their cell wall and even degrading the chemicals, but it is unclear as to what extent degradation occurs. The results also raise questions whether existing wastewater regulations should be expanded to include the detection and monitoring of PFAS, as well as the establishment of a regulatory wastewater treatment plant discharge standard for PFAS that is protective of human and ecological health.
Collapse
Affiliation(s)
- Zanina Ilieva
- Department of Civil Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada.
| | - Patricia Hania
- Department of Law and Business, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | - Roxana Suehring
- Department of Chemistry and Biology, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | - Kimberley Gilbride
- Department of Chemistry and Biology, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
| | - Rania Hamza
- Department of Civil Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada.
| |
Collapse
|
22
|
Dai M, Yan N, Brusseau ML. Potential impact of bacteria on the transport of PFAS in porous media. WATER RESEARCH 2023; 243:120350. [PMID: 37499541 PMCID: PMC10530518 DOI: 10.1016/j.watres.2023.120350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Revised: 07/05/2023] [Accepted: 07/11/2023] [Indexed: 07/29/2023]
Abstract
The transport and fate of per- and poly-fluoroalkyl substances (PFAS) in soil and groundwater is a topic of critical concern. A number of factors and processes may influence the transport and fate of PFAS in porous media. One factor that has received minimal attention to date is the impact of bacteria on the retention and transport of PFAS, which is the focus of this current study. The first part of this work comprised a critical review of prior studies to delineate observed PFAS-bacteria interactions and to summarize the mechanisms of PFAS sorption and retention by bacteria. Retention of PFAS by bacteria can occur through sorption onto cell surfaces and/or by incorporation into the cell interior. Factors such as the molecular structure of PFAS, solution chemistry, and bacterial species can affect the magnitude of PFAS sorption. The influence of bacteria on the retention and transport of PFAS was investigated in the second part of the study with a series of batch and miscible-displacement experiments. Batch experiments were conducted using Gram-negative Pseudomonas aeruginosa and Gram-positive Bacillus subtilis to quantify the sorption of perfluorooctane sulfonic acid (PFOS). The results indicated that both bacteria showed strong adsorption of PFOS, with no significant difference in adsorption capacity. Miscible-displacement experiments were then conducted to examine the retention and transport of PFOS in both untreated sand and sand inoculated with Pseudomonas aeruginosa or Bacillus subtilis for 1 and 3 days. The transport of PFOS exhibited greater retardation for the experiments with inoculated sand. Furthermore, the enhanced sorption was greater for the 3-day inoculation compared to the 1-day, indicating that biomass is an important factor affecting PFOS transport. A mathematical model representing transport with nonlinear and rate-limited sorption successfully simulated the observed PFOS transport. This study highlights the need for future studies to evaluate the effect of bacteria on the transport of PFAS in soil and groundwater.
Collapse
Affiliation(s)
- Mengfan Dai
- Key Lab of Marine Environmental Science and Ecology, Ministry of Education, College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100, China; Shandong Provincial Key Laboratory of Marine Environment and Geological Engineering, Ocean University of China, Qingdao 266100, China
| | - Ni Yan
- Key Lab of Marine Environmental Science and Ecology, Ministry of Education, College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100, China; Shandong Provincial Key Laboratory of Marine Environment and Geological Engineering, Ocean University of China, Qingdao 266100, China.
| | - Mark L Brusseau
- Environmental Science Department, University of Arizona, Tucson, AZ 85721, United States; Department of Hydrology and Atmospheric Sciences, University of Arizona, Tucson, AZ 85721, United States.
| |
Collapse
|
23
|
Kumar R, Dada TK, Whelan A, Cannon P, Sheehan M, Reeves L, Antunes E. Microbial and thermal treatment techniques for degradation of PFAS in biosolids: A focus on degradation mechanisms and pathways. JOURNAL OF HAZARDOUS MATERIALS 2023; 452:131212. [PMID: 36934630 DOI: 10.1016/j.jhazmat.2023.131212] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 03/09/2023] [Accepted: 03/13/2023] [Indexed: 05/03/2023]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are persistent organic chemicals detected in biosolids worldwide, which have become a significant concern for biosolids applications due to their increasing environmental risks. Hence, it is pivotal to understand the magnitude of PFAS contamination in biosolids and implement effective technologies to reduce their contamination and prevent hazardous aftermaths. Thermal techniques such as pyrolysis, incineration and gasification, and biodegradation have been regarded as impactful solutions to degrade PFAS and transform biosolids into value-added products like biochar. These techniques can mineralize PFAS compounds under specific operating parameters, which can lead to unique degradation mechanisms and pathways. Understanding PFAS degradation mechanisms can pave the way to design the technology and to optimize the process conditions. Therefore, in this review, we aim to review and compare PFAS degradation mechanisms in thermal treatment like pyrolysis, incineration, gasification, smouldering combustion, hydrothermal liquefaction (HTL), and biodegradation. For instance, in biodegradation of perfluorooctane sulfonic acid (PFOS), firstly C-S bond cleavage occurs which is followed by hydroxylation, decarboxylation and defluorination reactions to form perfluoroheptanoic acid. In HTL, PFOS degradation is carried through OH-catalyzed series of nucleophilic substitution and decarboxylation reactions. In contrast, thermal PFOS degradation involves a three-step random-chain scission pathway. The first step includes C-S bond cleavage, followed by defluorination of perfluoroalkyl radical, and radical chain propagation reactions. Finally, the termination of chain propagation reactions produces very short-fluorinated units. We also highlighted important policies and strategies employed worldwide to curb PFAS contamination in biosolids.
Collapse
Affiliation(s)
- Ravinder Kumar
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia
| | - Tewodros Kassa Dada
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia
| | - Anna Whelan
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia; Townsville City Council, Wastewater Operations, Townsville, QLD 4810, Australia
| | | | - Madoc Sheehan
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia
| | - Louise Reeves
- Queensland Water Directorate, Brisbane, QLD 4009, Australia
| | - Elsa Antunes
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia.
| |
Collapse
|
24
|
Mohona TM, Ye Z, Dai N, Nalam PC. Adsorption behavior of long-chain perfluoroalkyl substances on hydrophobic surface: A combined molecular characterization and simulation study. WATER RESEARCH 2023; 239:120074. [PMID: 37207455 DOI: 10.1016/j.watres.2023.120074] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 05/06/2023] [Accepted: 05/11/2023] [Indexed: 05/21/2023]
Abstract
Hydrophobic interaction is a prevalent sorption mechanism of poly- and perfluoroalkyl substances (PFAS) in natural and engineered environments. In this study, we combined quartz crystal microbalance with dissipation (QCM-D), atomic force microscope (AFM) with force mapping, and molecular dynamics (MD) simulation to probe the molecular behavior of PFAS at the hydrophobic interface. On a CH3-terminated self-assembled monolayer (SAM), perfluorononanoic acid (PFNA) showed ∼2-fold higher adsorption than perfluorooctane sulfonate (PFOS) that has the same fluorocarbon tail length but a different head group. Kinetic modeling using the linearized Avrami model suggests that the PFNA/PFOS-surface interaction mechanisms can evolve over time. This is confirmed by AFM force-distance measurements, which shows that while the adsorbed PFNA/PFOS molecules mostly lay flat, a portion of them formed aggregates/hierarchical structures of 1-10 nm in size after lateral diffusion on surface. PFOS showed a higher affinity to aggregate than PFNA. Association with air nanobubbles is observed for PFOS but not PFNA. MD simulations further showed that PFNA has a greater tendency than PFOS to have its tail inserted into the hydrophobic SAM, which can enhance adsorption but limit lateral diffusion, consistent with the relative behavior of PFNA/PFOS in QCM and AFM experiments. This integrative QCM-AFM-MD study reveals that the interfacial behavior of PFAS molecules can be heterogeneous even on a relatively homogeneous surface.
Collapse
Affiliation(s)
- Tashfia M Mohona
- Department of Civil, Structural and Environmental Engineering, University at Buffalo, Buffalo, NY, USA; Department of Materials Design and Innovation, University at Buffalo, Buffalo, NY, USA
| | - Zhijiang Ye
- Department of Mechanical and Manufacturing Engineering, Miami University, Oxford, OH, USA
| | - Ning Dai
- Department of Civil, Structural and Environmental Engineering, University at Buffalo, Buffalo, NY, USA.
| | - Prathima C Nalam
- Department of Materials Design and Innovation, University at Buffalo, Buffalo, NY, USA.
| |
Collapse
|
25
|
Kumar R, Whelan A, Cannon P, Sheehan M, Reeves L, Antunes E. Occurrence of emerging contaminants in biosolids in northern Queensland, Australia. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 330:121786. [PMID: 37156436 DOI: 10.1016/j.envpol.2023.121786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2023] [Revised: 05/04/2023] [Accepted: 05/06/2023] [Indexed: 05/10/2023]
Abstract
This study aims to identify and quantify different classes of emerging contaminants (ECs), such as pharmaceutical and personal care products (PPCPs), per-and polyfluoroalkyl substances (PFAS), heavy metals (HMs), polycyclic musks (PMs) in biosolids from different sewage treatment plants (STPs) from regional councils across Northern Queensland, Australia. Biosolids samples were named BS1 to BS7 for each council. The results revealed significant variations in the concentrations of different ECs in biosolids which could be explained in some instances by the characteristics of the upstream sewage network. For instance, BS4-biosolids from a small agricultural shire (largely sugarcane) showed the highest concentration of zinc and copper, which were 2430 and 1050 mg/kg, respectively. Among PPCPs, the concentration of ciprofloxacin was found to be the highest in BS3 and BS5, two large regional council areas which are a mix of domestic and industrial (predominantly domestic) biosolids of 1010 and 1590 ng/g, respectively. In addition, the quantity of sertraline was consistently high in all biosolids except from BS7, one of the smaller regional councils, which is indicative of the domestic catchments attached. PFAS compounds were detected in all biosolids samples except in BS6, one of the small (agricultural and tourist) catchments. Two PFAS compounds emerged as the most common pollutants that were perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS). The largest industrial catchment biosolids, BS2 showed the highest concentration of PFOS at 253 ng/g, while the smallest regional council, BS7 showed the maximum concentration of 7.90 ng/g of PFOA. Overall, this study concludes that certain ECs such as HMs, antibiotics, PFOS and PFOA in biosolids may pose high environmental risks.
Collapse
Affiliation(s)
- Ravinder Kumar
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia
| | - Anna Whelan
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia; Townsville City Council, Wastewater Operations, Townsville, QLD, 4810, Australia
| | | | - Madoc Sheehan
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia
| | - Louise Reeves
- Queensland Water Directorate, Brisbane, QLD, 4009, Australia
| | - Elsa Antunes
- College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia.
| |
Collapse
|
26
|
Schaefer CE, Hooper JL, Strom LE, Abusallout I, Dickenson ERV, Thompson KA, Mohan GR, Drennan D, Wu K, Guelfo JL. Occurrence of quantifiable and semi-quantifiable poly- and perfluoroalkyl substances in united states wastewater treatment plants. WATER RESEARCH 2023; 233:119724. [PMID: 36801573 DOI: 10.1016/j.watres.2023.119724] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 02/06/2023] [Accepted: 02/08/2023] [Indexed: 06/18/2023]
Abstract
Both quantifiable and semi-quantifiable poly- and perfluoroalkyl substances (PFAS) were evaluated in the influent, effluent, and biosolids of 38 wastewater treatment plants. PFAS were detected in all streams at all facilities. For the means of the sums of detected, quantifiable PFAS concentrations were 98 ± 28 ng/L, 80 ± 24 ng/L, and 160,000 ± 46,000 ng/kg (dry weight basis) in the influent, effluent, and biosolids (respectively). In the aqueous influent and effluent streams this quantifiable PFAS mass was typically associated with perfluoroalkyl acids (PFAAs). In contrast, quantifiable PFAS in the biosolids were primarily polyfluoroalkyl substances that potentially serve as precursors to the more recalcitrant PFAAs. Results of the total oxidizable precursor (TOP) assay on select influent and effluent samples showed that semi-quantified (or, unidentified) precursors accounted for a substantial portion (21 to 88%) of the fluorine mass compared to that associated with quantified PFAS, and that this fluorine precursor mass was not appreciably transformed to perfluoroalkyl acids within the WWTPs, as influent and effluent precursor concentrations via the TOP assay were statistically identical. Evaluation of semi-quantified PFAS, consistent with results of the TOP assay, showed the presence of several classes of precursors in the influent, effluent, and biosolids; perfluorophosphonic acids (PFPAs) and fluorotelomer phosphate diesters (di-PAPs) occurred in 100 and 92% of biosolid samples, respectively. Analysis of mass flows showed that, for both quantified (on a fluorine mass basis) and semi-quantified PFAS, the majority of PFAS exited WWTPs through the aqueous effluent compared to the biosolids stream. Overall, these results highlight the importance of semi-quantified PFAS precursors in WWTPs, and the need to further understand the impacts of their ultimate fate in the environment.
Collapse
Affiliation(s)
| | | | - Laurel E Strom
- CDM Smith, 14432 SE Eastgate Way Suite 100, Bellevue, WA 98007, USA
| | | | - Eric R V Dickenson
- Water Quality Research and Development, Southern Nevada Water Authority, 1299 Burkholder Blvd., Henderson, NV, 89015, USA
| | - Kyle A Thompson
- Water Quality Research and Development, Southern Nevada Water Authority, 1299 Burkholder Blvd., Henderson, NV, 89015, USA; Carollo Engineers, 8911N Capital of Texas Hwy, Austin, TX 78759, USA
| | - Gayathri Ram Mohan
- Gwinnett County Department of Water Resources, Lawrenceville, GA 30045, USA
| | - Dina Drennan
- CDM Smith, 14432 SE Eastgate Way Suite 100, Bellevue, WA 98007, USA
| | - Ke Wu
- Department of Civil, Environmental & Construction Engineering, Texas Tech University, Lubbock, TX 79409, USA
| | - Jennifer L Guelfo
- Department of Civil, Environmental & Construction Engineering, Texas Tech University, Lubbock, TX 79409, USA
| |
Collapse
|
27
|
Adu O, Ma X, Sharma VK. Bioavailability, phytotoxicity and plant uptake of per-and polyfluoroalkyl substances (PFAS): A review. JOURNAL OF HAZARDOUS MATERIALS 2023; 447:130805. [PMID: 36669401 DOI: 10.1016/j.jhazmat.2023.130805] [Citation(s) in RCA: 56] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 01/12/2023] [Accepted: 01/14/2023] [Indexed: 06/17/2023]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are a group of legacy and emerging contaminants containing at least one aliphatic perfluorocarbon moiety. They display rapid and extensive transport in the environment due to their generally high water-solubility and weak adsorption onto soil particles. Because of their widespread presence in the environment and known toxicity, PFAS has become a serious threat to the ecosystem and public health. Plants are an essential component of the ecosystem and their uptake and accumulation of PFAS affect the fate and transport of PFAS in the ecosystem and has strong implications for human health. It is therefore imperative to investigate the interactions of plants with PFAS. This review presents a detailed discussion on the mechanisms of the bioavailability and plant uptake of PFAS, and essential factors affecting these processes. The phytotoxic effects of PFAS at physiological, biochemical, and molecular level were also carefully reviewed. At the end, key research gaps were identified, and future research needs were proposed.
Collapse
Affiliation(s)
- Olatunbosun Adu
- Department of Water Management and Hydrological Science, Texas A&M University, College Station, TX 77843, USA; Program for the Environment and Sustainability, Department of Environmental and Occupational Health, School of Public Health, Texas A&M University, 212 Adriance Lab Rd., 1266 TAMU, College Station, TX 77843, USA
| | - Xingmao Ma
- Department of Civil and Environmental Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Virender K Sharma
- Program for the Environment and Sustainability, Department of Environmental and Occupational Health, School of Public Health, Texas A&M University, 212 Adriance Lab Rd., 1266 TAMU, College Station, TX 77843, USA.
| |
Collapse
|
28
|
Sleep JA, Miklavcic SJ, Juhasz AL. Modelling of PFAS-surface interactions: Effect of surface charge and solution ions. CHEMOSPHERE 2023; 319:137910. [PMID: 36706812 DOI: 10.1016/j.chemosphere.2023.137910] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 12/01/2022] [Accepted: 01/17/2023] [Indexed: 06/18/2023]
Abstract
PER-: and poly-fluoroalkyl substances (PFAS) are a class of substances of increasing concern as environmental contaminants. The interactions between PFAS and surfaces play an important role in PFAS transport and remediation. Previous studies have found PFAS adsorption to be dependent upon properties including pH, organic matter and particle size, along with PFAS functional group and carbon chain length. It is hypothesised that a theoretical examination of PFAS-surface interactions, via Monte Carlo molecular simulation, would show differences resulting from changes in surface charge, H+, OH-, Ca2+ concentrations and PFAS carbon chain length. Monte Carlo molecular simulations of perfluorooctane and perfluorobutane sulfonic acids interacting with a graphite surface in an aqueous medium were performed. Variations in surface charge, H+, OH- and Ca2+ concentrations were made. The distance-dependent density of molecules from the surface was analysed as a proxy for PFAS adsorption to the surface. Simulation results showed differences in surface behaviour that depended on surface charge, H+, OH- and Ca2+ concentrations, along with carbon chain length, with surface charge playing the most prominent role in controlling PFAS adsorption. For negatively charged surfaces, adsorption due to divalent cation bridging was observed in Ca2+ solutions. Modelling, such as in this study, of the thermodynamic equilibrium behaviour of low concentrations of molecules, in scenarios where both adsorption and mobility of PFAS occur, can aid in the design and testing of sorptive surfaces for amendment-based PFAS remediation.
Collapse
Affiliation(s)
- Julie A Sleep
- Future Industries Institute, University of South Australia, Mawson Lakes, SA, 5095, Australia.
| | - Stanley J Miklavcic
- Phenomics and Bioinformatics Research Centre, University of South Australia, Mawson Lakes, SA, 5095, Australia.
| | - Albert L Juhasz
- Future Industries Institute, University of South Australia, Mawson Lakes, SA, 5095, Australia.
| |
Collapse
|
29
|
Gravesen CR, Lee LS, Choi YJ, Silveira ML, Judy JD. PFAS release from wastewater residuals as a function of composition and production practices. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 322:121167. [PMID: 36731742 PMCID: PMC10597385 DOI: 10.1016/j.envpol.2023.121167] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 01/11/2023] [Accepted: 01/27/2023] [Indexed: 06/18/2023]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are a class of highly persistent contaminants that have been linked to human health effects at low exposure concentrations. Public concerns exist that land-application of biosolids may result in the release of PFAS into terrestrial and aquatic ecosystems. The relative importance of inorganic constituents such as Fe and Al, which are known to impact PFAS retention/release behavior in soils, on PFAS release from wastewater residuals (WWRs, i.e., biosolids and sewage sludges) is not well understood. Here, we examine native concentrations and WWR-water partition coefficients of a range of PFAS in the context of WWRs characteristics including oxalate-extractable Fe and Al, organic matter (OM), dissolved organic carbon, and total protein content. Total PFAS concentrations, which included perfluoroalkyl carboxylates, perfluoroalkyl sulfonates, fluorotelomer sulfonates and some sulfonamides, ranged from ∼480 to 3500 μg PFAS kg-1 dry weight. PFAS WWR-water partition coefficients ranged from ∼10 to 20,000 L kg-1, consistent with the literature. PFAS partitioning was significantly correlated to oxalate extractable Al and Fe as well as bulk OM and protein content. These results have important implications for wastewater treatment facilities that recycle Al- and Fe-based drinking water treatment residuals in terms of both PFAS retention and loading.
Collapse
Affiliation(s)
- Caleb R Gravesen
- University of Florida, Department of Soil and Water Sciences, Gainesville, FL, USA
| | - Linda S Lee
- Purdue University, Department of Agronomy, West Lafayette, IN, USA; Purdue University, Ecological Sciences & Engineering Interdisciplinary Graduate Program, West Lafayette, IN, USA; Purdue University, Environmental & Ecological Engineering, West Lafayette, IN, USA
| | - Youn Jeong Choi
- Purdue University, Department of Agronomy, West Lafayette, IN, USA
| | - Maria L Silveira
- University of Florida, Range Cattle Research and Education Center, Ona, FL, USA
| | - Jonathan D Judy
- University of Florida, Department of Soil and Water Sciences, Gainesville, FL, USA.
| |
Collapse
|
30
|
Mu H, Wang J, Chen L, Hu H, Wang J, Gu C, Ren H, Wu B. Identification and characterization of diverse isomers of per- and polyfluoroalkyl substances in Chinese municipal wastewater. WATER RESEARCH 2023; 230:119580. [PMID: 36638730 DOI: 10.1016/j.watres.2023.119580] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 12/26/2022] [Accepted: 01/04/2023] [Indexed: 06/17/2023]
Abstract
Linear and branched isomers of per- and polyfluoroalkyl substances (PFASs) are simultaneously present in the environment. However, isomer profiles of PFASs in municipal wastewater treatment plants (WWTPs) are still unknown because of the limitations of standards. Here, influent and effluent samples from 148 municipal WWTPs in China were collected. Ion mobility spectrometry was introduced into high-resolution mass spectrometry-based suspect screening methods to identify the target and suspect PFAS isomers. A total of 38 branched isomers of 14 typical PFASs were identified in wastewater samples. Linear PFASs had higher detection rates (22.3%-100%) than branched isomers (2.0%-98%). Compared to the influents, proportions of branched isomers of most PFASs (except for perfluoropentanoic acid and perfluorohexanoic acid) increased in the effluents. The conventional biological treatment processes (such as anaerobic-anoxic-aerobic and oxidation ditch treatments) had poor removal efficiency for linear PFASs (<21.4%) and branched isomers (<13.4%). No difference on removal efficiency among treatment processes was found. Furthermore, isomer composition in the WWTPs showed obvious differences between East China region and other regions, and the usage of short-chain PFASs (perfluorobutanesulfonic acid and perfluorohexanesulfonic acid) may be a key factor for driving this difference. This study sheds lights on the identification and characterization of PFAS isomers in WWTPs, which would be useful for development of monitoring and control strategies of PFASs.
Collapse
Affiliation(s)
- Hongxin Mu
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing, 210023, China
| | - Jiawei Wang
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing, 210023, China
| | - Ling Chen
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing, 210023, China
| | - Haidong Hu
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing, 210023, China
| | - Jinfeng Wang
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing, 210023, China
| | - Cheng Gu
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing, 210023, China
| | - Hongqiang Ren
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing, 210023, China
| | - Bing Wu
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing, 210023, China.
| |
Collapse
|
31
|
Liu X, Huang X, Wei X, Zhi Y, Qian S, Li W, Yue D, Wang X. Occurrence and removal of per- and polyfluoroalkyl substances (PFAS) in leachates from incineration plants: A full-scale study. CHEMOSPHERE 2023; 313:137456. [PMID: 36470352 DOI: 10.1016/j.chemosphere.2022.137456] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 11/27/2022] [Accepted: 12/01/2022] [Indexed: 06/17/2023]
Abstract
Municipal solid wastes (MSWs) contain diverse per- and polyfluoroalkyl substances (PFAS), and these substances may leach into leachates, resulting in potential threats to the environment and human health. In this study, leachates from incineration plants with on-site treatment systems were measured for 17 PFAS species, including 13 perfluorocarboxylic acids (PFCAs) and 4 perfluorosulfonic acids (PFSAs). PFAS were detected in all of the raw leachates and finished effluents in concentrations ranging from 7228 to 16,565 ng L-1 and 43 to 184 ng L-1, respectively, with a greater contribution from the short-chain PFAS and PFCAs. The results showed that the existing combined processes (biological treatment and membrane filtration) were effective in decreasing PFAS in the aqueous phase with removal efficiencies over 95%. In addition, correlation analysis suggested that physical entrapment, not biodegradation, was the main means of PFAS reduction in the treatment system. These results filled a gap in the understanding of PFAS occurrence and removal in leachates from incineration plants during the full-scale treatment processes, and demonstrated those leachates were previously under-explored sources of PFAS.
Collapse
Affiliation(s)
- Xuemei Liu
- Key Laboratory of Three Gorges Reservoir Region's Eco-Environment Under Ministry of Education, Chongqing University, Chongqing, 400044, China
| | - Xingyao Huang
- Key Laboratory of Three Gorges Reservoir Region's Eco-Environment Under Ministry of Education, Chongqing University, Chongqing, 400044, China
| | - Xiaoxiao Wei
- Key Laboratory of Three Gorges Reservoir Region's Eco-Environment Under Ministry of Education, Chongqing University, Chongqing, 400044, China
| | - Yue Zhi
- Key Laboratory of Three Gorges Reservoir Region's Eco-Environment Under Ministry of Education, Chongqing University, Chongqing, 400044, China
| | - Shenhua Qian
- Key Laboratory of Three Gorges Reservoir Region's Eco-Environment Under Ministry of Education, Chongqing University, Chongqing, 400044, China; Department of Ecological Engineering, Chongqing University, Chongqing, 400044, China
| | - Wei Li
- Key Laboratory of Three Gorges Reservoir Region's Eco-Environment Under Ministry of Education, Chongqing University, Chongqing, 400044, China; Department of Ecological Engineering, Chongqing University, Chongqing, 400044, China
| | - Dongbei Yue
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Xiaoming Wang
- Key Laboratory of Three Gorges Reservoir Region's Eco-Environment Under Ministry of Education, Chongqing University, Chongqing, 400044, China; Department of Environmental Engineering, Chongqing University, Chongqing, 400044, China.
| |
Collapse
|
32
|
Jiang L, Yao J, Ren G, Sheng N, Guo Y, Dai J, Pan Y. Comprehensive profiles of per- and polyfluoroalkyl substances in Chinese and African municipal wastewater treatment plants: New implications for removal efficiency. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 857:159638. [PMID: 36280053 DOI: 10.1016/j.scitotenv.2022.159638] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 10/09/2022] [Accepted: 10/18/2022] [Indexed: 06/16/2023]
Abstract
Municipal wastewater treatment plants (WWTPs) can reflect the pollution status of per- and polyfluoroalkyl substances (PFASs) pollution. Here, matched influent, effluent, and sludge samples were collected from 58 municipal WWTPs in China, South Sudan, Tanzania, and Kenya. Target and suspect screening of PFASs was performed to explore their profiles in WWTPs and assess removal efficiency and environmental emissions. In total, 155 and 58 PFASs were identified in WWTPs in China and Africa, respectively; 146 and 126 PFASs were identified in wastewater and sludge, respectively. Novel compounds belonging to per- and polyfluoroalkyl ether carboxylic acids (PFECAs) and sulfonic acids (PFESAs), hydrogen-substituted polyfluorocarboxylic acids (H-PFCAs), and perfluoroalkyl sulfonamides (PFSMs) accounted for a considerable proportion of total PFASs (ΣPFASs) in Chinese WWTPs and were also widely detected in African samples. In China, estimated national emissions of ΣPFASs in WWTPs exceeded 16.8 t in 2015, with >60 % originating from emerging PFASs. Notably, current treatment processes are not effective at removing PFASs, with 35 of the 54 WWTPs showing emissions higher than mass loads. PFAS removal was also structure dependent. Based on machine learning models, we found that molecular descriptors (e.g., LogP and molecular weight) may affect adsorption behavior by increasing hydrophobicity, while other factors (e.g., polar surface area and molar refractivity) may play critical roles in PFAS removal and provide novel insights into PFAS pollution control. In conclusion, this study comprehensively screened PFASs in municipal WWTPs and determined the drivers affecting PFAS behavior in WWTPs based on machine learning models.
Collapse
Affiliation(s)
- Lulin Jiang
- State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Jingzhi Yao
- State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Ge Ren
- National Institute of Metrology, Beijing 100029, China
| | - Nan Sheng
- State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yong Guo
- Key Laboratory of Organofluorine Chemistry, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Jiayin Dai
- State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yitao Pan
- State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|
33
|
Chen Y, Zhang H, Liu Y, Bowden JA, Tolaymat TM, Townsend TG, Solo-Gabriele HM. Concentrations of perfluoroalkyl and polyfluoroalkyl substances before and after full-scale landfill leachate treatment. WASTE MANAGEMENT (NEW YORK, N.Y.) 2022; 153:110-120. [PMID: 36084369 PMCID: PMC10463282 DOI: 10.1016/j.wasman.2022.08.024] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/23/2022] [Accepted: 08/25/2022] [Indexed: 06/15/2023]
Abstract
Many consumer and industrial products, industrial wastes and dewatered sludge from municipal wastewater treatment plants containing per- and polyfluoroalkyl substances (PFAS) are disposed of in landfills at the end of their usage, with PFAS in these products leached into landfill leachates. On-site leachate treatment is one possible method to reduce PFAS in leachates. Many landfills are equipped with on-site leachate treatment systems, but few full-scale facilities have been systematically evaluated for PFAS concentration changes. The objective of this study was to evaluate a cross-section of full-scale on-site landfill treatment systems to measure changes in PFAS concentrations. Leachate samples were collected before and after treatment from 15 facilities and were evaluated for 26 PFAS, including 11 perfluoroalkyl carboxylic acids (PFCAs), 7 perfluoroalkyl sulfonic acids (PFSAs), and 8 perfluoroalkyl acid precursors (PFAA-precursors). Transformation of precursors was evaluated by the total oxidizable precursor (TOP) assay. Results showed no obvious reductions in total measured PFAS (∑26PFAS) for on-site treatment systems including ponds, aeration tanks, powdered activated carbon (PAC), and sand filtration. Among evaluated on-site treatment systems, only systems fitted with reverse osmosis (RO) showed significant reductions (98-99 %) of ∑26PFAS in the permeate. Results from the TOP assay showed that untargeted PFAA-precursors converted into targeted short-chain PFCAs increasing ∑26PFAS in oxidized samples by 30 %, on average. Overall, results of this study confirm the efficacy of RO systems and suggest the presence of additional precursors beyond those measured in this study.
Collapse
Affiliation(s)
- Yutao Chen
- Department of Civil, Architectural, and Environmental Engineering, College of Engineering, University of Miami, Coral Gables, FL 33146, United States
| | - Hekai Zhang
- Department of Civil, Architectural, and Environmental Engineering, College of Engineering, University of Miami, Coral Gables, FL 33146, United States
| | - Yalan Liu
- Department of Environmental Engineering Sciences, College of Engineering, University of Florida, Gainesville, FL 32611, United States
| | - John A Bowden
- Department of Environmental Engineering Sciences, College of Engineering, University of Florida, Gainesville, FL 32611, United States; Center for Environmental and Human Toxicology & Department of Physiological Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL 32610, United States
| | - Thabet M Tolaymat
- Center for Environmental Solutions and Emergency Response, Office of Research and Development, U.S. Environmental Protection Agency, Cincinnati, OH 45268, United States
| | - Timothy G Townsend
- Department of Environmental Engineering Sciences, College of Engineering, University of Florida, Gainesville, FL 32611, United States
| | - Helena M Solo-Gabriele
- Department of Civil, Architectural, and Environmental Engineering, College of Engineering, University of Miami, Coral Gables, FL 33146, United States.
| |
Collapse
|
34
|
Das S, Ronen A. A Review on Removal and Destruction of Per- and Polyfluoroalkyl Substances (PFAS) by Novel Membranes. MEMBRANES 2022; 12:662. [PMID: 35877866 PMCID: PMC9325267 DOI: 10.3390/membranes12070662] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 06/20/2022] [Accepted: 06/22/2022] [Indexed: 02/01/2023]
Abstract
Per- and Polyfluoroalkyl Substances (PFAS) are anthropogenic chemicals consisting of thousands of individual species. PFAS consists of a fully or partly fluorinated carbon-fluorine bond, which is hard to break and requires a high amount of energy (536 kJ/mole). Resulting from their unique hydrophobic/oleophobic nature and their chemical and mechanical stability, they are highly resistant to thermal, chemical, and biological degradation. PFAS have been used extensively worldwide since the 1940s in various products such as non-stick household items, food-packaging, cosmetics, electronics, and firefighting foams. Exposure to PFAS may lead to health issues such as hormonal imbalances, a compromised immune system, cancer, fertility disorders, and adverse effects on fetal growth and learning ability in children. To date, very few novel membrane approaches have been reported effective in removing and destroying PFAS. Therefore, this article provides a critical review of PFAS treatment and removal approaches by membrane separation systems. We discuss recently reported novel and effective membrane techniques for PFAS separation and include a detailed discussion of parameters affecting PFAS membrane separation and destruction. Moreover, an estimation of cost analysis is also included for each treatment technology. Additionally, since the PFAS treatment technology is still growing, we have incorporated several future directions for efficient PFAS treatment.
Collapse
Affiliation(s)
| | - Avner Ronen
- Zuckerberg Institute for Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Sede-Boqer Campus 84990, Israel;
| |
Collapse
|
35
|
Schaefer CE, Hooper J, Modiri-Gharehveran M, Drennan DM, Beecher N, Lee L. Release of poly- and perfluoroalkyl substances from finished biosolids in soil mesocosms. WATER RESEARCH 2022; 217:118405. [PMID: 35417820 DOI: 10.1016/j.watres.2022.118405] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 03/24/2022] [Accepted: 04/03/2022] [Indexed: 06/14/2023]
Abstract
Finished biosolids were collected and characterized from seven municipal water resource recovery facilities. Poly- and perfluoroalkyl substances (PFAS) for the 54 quantified in the biosolids ranged from 323 ± 14.1 to 1100 ± 43.8 µg/kg (dry weight basis). For all biosolids, greater than 75% of the PFAS fluorine mass was associated with precursors. Di-substituted polyfluorinated phosphate esters (diPAPs) were the most abundant PFAS identified in the biosolids. The total oxidizable precursor assay on biosolids extracts generally failed to quantify the amount of precursors present, in large part due to the fact that diPAPS were not fully transformed during the TOP assay. Outdoor biosolids column leaching experiments intended to simulate biosolids land application showed sustained PFAS leaching over the 6-month study duration. Perfluoroalkyl acid (PFAA) concentrations in leachate, when detected, typically ranged in the 10 s to 100 s of ng/L; no diPAPs were detected in the leachate. The PFAA leaching from the biosolids exceeded the PFAA mass initially present in the biosolids (typically by greater than an order of magnitude), but the cumulative PFAA mass leached did not exceed the molar equivalents that could be explained by transformation of quantified precursors. These results highlight the importance of PFAA precursors initially present in biosolids and their contribution to long term leaching of PFAAs from land-applied biosolids.
Collapse
Affiliation(s)
| | - Jennifer Hooper
- CDM Smith, 14432 SE Eastgate Way # 100, Bellevue, WA, 98007, USA
| | | | - Dina M Drennan
- CDM Smith, 14432 SE Eastgate Way # 100, Bellevue, WA, 98007, USA
| | - Ned Beecher
- North East Biosolids and Residuals Association (NEBRA), USA
| | - Linda Lee
- Department of Agronomy, Purdue University, West Lafayette, IN, 47907-2054, USA; Interdisciplinary Ecological Sciences & Engineering, Environmental & Ecological Engineering, Purdue University, West Lafayette, IN, 47907-2054, USA
| |
Collapse
|
36
|
Wu JY, Hua ZL, Gu L, Li XQ, Gao C, Liu YY. Perfluorinated compounds (PFCs) in regional industrial rivers: Interactions between pollution flux and eukaryotic community phylosymbiosis. ENVIRONMENTAL RESEARCH 2022; 203:111876. [PMID: 34400162 DOI: 10.1016/j.envres.2021.111876] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/21/2021] [Accepted: 08/09/2021] [Indexed: 06/13/2023]
Abstract
Perfluorinated compounds (PFCs) pose serious threats to aquatic ecosystems, especially their microbial communities. However, little is known about the phylosymbiosis of aquatic fungal and viridiplantae communities in response to PFC accumulation. We quantified the distribution of 14 PFCs in rivers and found that PFBA was dominant in the transition from water to sediment. High through-put sequencing revealed that phyla Ascomycota, Basidiomycota, Anthophyta, and Chlorophyta were the predominant in eukaryotic community. The effects of PFCs on spatial community coalescence at taxonomic and phylogenetic levels (p < 0.05) were revealed. Fungal community coalescence triggered the spatial assembly of fungal and viridiplantae communities in riverine environments (p < 0.05). Null modeling indicated that PFBA, PFTrDA and PFOS, etc, mediated phylogenetic assembly (p < 0.05) and stochastic processes (86.67-100%) maintain phylogenetic turnover in the fungal community. Meanwhile, variable selection (27.78-54.44%) explained the viridiplantae community assemblage. Finally, we identified fungal genera Hannaella, Naganishia, Purpureocillium and Stachybotrys as indicators for PFC pollution (p < 0.001). These results help explain the effects of PFCs on riverine ecological remediation.
Collapse
Affiliation(s)
- Jian-Yi Wu
- Key Laboratory of Integrated Regulation and Resource Development on Shallow Lake of Ministry of Education, College of Environment, Hohai University, Nanjing, 210098, China; Yangtze Institute for Conservation and Development, Hohai University, Jiangsu, 210098, China
| | - Zu-Lin Hua
- Key Laboratory of Integrated Regulation and Resource Development on Shallow Lake of Ministry of Education, College of Environment, Hohai University, Nanjing, 210098, China; Yangtze Institute for Conservation and Development, Hohai University, Jiangsu, 210098, China
| | - Li Gu
- Key Laboratory of Integrated Regulation and Resource Development on Shallow Lake of Ministry of Education, College of Environment, Hohai University, Nanjing, 210098, China; Yangtze Institute for Conservation and Development, Hohai University, Jiangsu, 210098, China.
| | - Xiao-Qing Li
- Key Laboratory of Integrated Regulation and Resource Development on Shallow Lake of Ministry of Education, College of Environment, Hohai University, Nanjing, 210098, China; Yangtze Institute for Conservation and Development, Hohai University, Jiangsu, 210098, China
| | - Chang Gao
- Key Laboratory of Integrated Regulation and Resource Development on Shallow Lake of Ministry of Education, College of Environment, Hohai University, Nanjing, 210098, China; Yangtze Institute for Conservation and Development, Hohai University, Jiangsu, 210098, China
| | - Yuan-Yuan Liu
- Key Laboratory of Integrated Regulation and Resource Development on Shallow Lake of Ministry of Education, College of Environment, Hohai University, Nanjing, 210098, China; Yangtze Institute for Conservation and Development, Hohai University, Jiangsu, 210098, China
| |
Collapse
|
37
|
Barisci S, Suri R. Occurrence and removal of poly/perfluoroalkyl substances (PFAS) in municipal and industrial wastewater treatment plants. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2021; 84:3442-3468. [PMID: 34928819 DOI: 10.2166/wst.2021.484] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The presence of poly- and perfluoroalkyl substances (PFAS) has caused serious problems for drinking water supplies especially at intake locations close to PFAS manufacturing facilities, wastewater treatment plants (WWTPs), and sites where PFAS-containing firefighting foam was regularly used. Although monitoring is increasing, knowledge on PFAS occurrences particularly in municipal and industrial effluents is still relatively low. Even though the production of C8-based PFAS has been phased out, they are still being detected at many WWTPs. Emerging PFAS such as GenX and F-53B are also beginning to be reported in aquatic environments. This paper presents a broad review and discussion on the occurrence of PFAS in municipal and industrial wastewater which appear to be their main sources. Carbon adsorption and ion exchange are currently used treatment technologies for PFAS removal. However, these methods have been reported to be ineffective for the removal of short-chain PFAS. Several pioneering treatment technologies, such as electrooxidation, ultrasound, and plasma have been reported for PFAS degradation. Nevertheless, in-depth research should be performed for the applicability of emerging technologies for real-world applications. This paper examines different technologies and helps to understand the research needs to improve the development of treatment processes for PFAS in wastewater streams.
Collapse
Affiliation(s)
- Sibel Barisci
- Civil and Environmental Engineering Department, Water and Environmental Technology (WET) Center, Temple University, 1947 N 12th Street, Philadelphia, PA 19122, USA E-mail:
| | - Rominder Suri
- Civil and Environmental Engineering Department, Water and Environmental Technology (WET) Center, Temple University, 1947 N 12th Street, Philadelphia, PA 19122, USA E-mail:
| |
Collapse
|
38
|
Zhang W, Liang Y. Effects of hydrothermal treatments on destruction of per- and polyfluoroalkyl substances in sewage sludge. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 285:117276. [PMID: 33964564 DOI: 10.1016/j.envpol.2021.117276] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 04/26/2021] [Accepted: 04/27/2021] [Indexed: 06/12/2023]
Abstract
Sewage sludge has become a sink of per- and polyfluoroalkyl substances (PFAS) due to the ineffectiveness of PFAS removal during conventional activated sludge treatment process. In this study, we evaluated the performance of an enhanced method for PFAS extraction from sewage sludge. Significant matrix effect was observed for samples derived from untreated and hydrothermally treated sludge. Extra steps for removing potential interferences were thus needed to reduce these matrix effects and improve the accuracy of PFAS quantification. Hydrothermal treatment at 165 °C for 0.5/2 h and 250 °C for 0.5 h increased the concentration of extractable PFAAs in treated sludge. Increasing the temperature to 300 °C resulted in complete degradation of PFCAs after hydrothermal processing, but still increased the concentrations of PFSAs and PFAA precursors. The concentration increase could be due to the conversion of PFAA precursors to PFAAs and the release of PFAAs from sewage sludge during thermal treatment. Ca(OH)2 addition to hydrothermal treatment completely removed PFAA precursors but significantly increased the extractable PFAAs, except PFHpA and PFHxS, at 165 °C and all PFSAs at 300 °C. This study revealed the difficulties in extracting and quantifying PFAS in sludge and demonstrated the need for further research on finding suitable solutions for complete removal or destruction of PFAS in highly heterogeneous sewage sludge.
Collapse
Affiliation(s)
- Weilan Zhang
- Department of Environmental and Sustainable Engineering, University at Albany, State University of New York, 1400 Washington Avenue, Albany, NY, 12222, USA.
| | - Yanna Liang
- Department of Environmental and Sustainable Engineering, University at Albany, State University of New York, 1400 Washington Avenue, Albany, NY, 12222, USA
| |
Collapse
|
39
|
Lenka SP, Kah M, Padhye LP. A review of the occurrence, transformation, and removal of poly- and perfluoroalkyl substances (PFAS) in wastewater treatment plants. WATER RESEARCH 2021; 199:117187. [PMID: 34010737 DOI: 10.1016/j.watres.2021.117187] [Citation(s) in RCA: 241] [Impact Index Per Article: 60.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Revised: 04/19/2021] [Accepted: 04/20/2021] [Indexed: 05/26/2023]
Abstract
Poly- and perfluoroalkyl substances (PFAS) comprise more than 4,000 anthropogenically manufactured compounds with widescale consumer and industrial applications. This critical review compiles the latest information on the worldwide distribution of PFAS and evaluates their fate in wastewater treatment plants (WWTPs). A large proportion (>30%) of monitoring studies in WWTPs were conducted in China, followed by Europe (30%) and North America (16%), whereas information is generally lacking for other parts of the world, including most of the developing countries. Short and long-chain perfluoroalkyl acids (PFAAs) were widely detected in both the influents (up to 1,000 ng/L) and effluents (15 to >1,500 ng/L) of WWTPs. To date, limited data is available regarding levels of PFAS precursors and ultra-short chain PFAS in WWTPs. Most WWTPs exhibited low removal efficiencies for PFAS, and many studies reported an increase in the levels of PFAAs after wastewater treatment. The analysis of the fate of various classes of PFAS at different wastewater treatment stages (aerobic and/aerobic biodegradation, photodegradation, and chemical degradation) revealed biodegradation as the primary mechanism responsible for the transformation of PFAS precursors to PFAAs in WWTPs. Remediation studies at full scale and laboratory scale suggest advanced processes such as adsorption using ion exchange resins, electrochemical degradation, and nanofiltration are more effective in removing PFAS (~95-100%) than conventional processes. However, the applicability of such treatments for real-world WWTPs faces significant challenges due to the scaling-up requirements, mass-transfer limitations, and management of treatment by-products and wastes. Combining more than one technique for effective removal of PFAS, while addressing limitations of the individual treatments, could be beneficial. Considering environmental concentrations of PFAS, cost-effectiveness, and ease of operation, nanofiltration followed by adsorption using wood-derived biochar and/or activated carbons could be a viable option if introduced to conventional treatment systems. However, the large-scale applicability of the same needs to be further verified.
Collapse
Affiliation(s)
| | - Melanie Kah
- School of Environment, The University of Auckland, Auckland, New Zealand
| | - Lokesh P Padhye
- Department of Civil and Environmental Engineering, The University of Auckland, Auckland, New Zealand.
| |
Collapse
|