1
|
Kiwanuka MJ, Nomngongo PN, Mketo N. Ultrasound assisted magnetic dispersive solid phase microextraction for Hg determination in fuel oils using inductively coupled plasma optical emission spectroscopy. Sci Rep 2025; 15:16557. [PMID: 40360702 DOI: 10.1038/s41598-025-01447-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2024] [Accepted: 05/06/2025] [Indexed: 05/15/2025] Open
Abstract
Mercury is considered a global pollutant, and its quantification in fuel oils remains a priority for public health and the ecosystem. Functionalized graphene oxide has gained popularity for heavy metal adsorption in various matrices. Herein we present a highly selective and efficient magnetic graphene oxide coated with gold (Fe3O4/GO-Au) nano adsorbent and its application to a dispersive solid-phase microextraction of mercury in fuel oils. The synthesized Fe3O4/GO-Au nanocomposite was characterized using Fourier Transform Infra-Red spectroscopy (FT-IR), powder X-ray diffraction (P-XRD), Scanning electron microscopy (SEM/EDS), Transmission electron microscopy (TEM), Thermogravimetric (TGA), Brunauer-Emmett-Teller (BET), and vibration sample magnetometer (VSM) analysis. The multivariate optimum conditions for the extraction method were 20 min, 30 mg, pH 7, and 1.75 mol/L, for adsorption time, sorbent mass, pH, and eluent concentration, respectively. Under the optimized conditions, the dynamic linear range of 0.1 to 100 µg/L (R2 = 0.999) was obtained. The limit of detection (LOD) and preconcentration factor obtained were 0.035 µg/L and 255, respectively. Intra- and inter-day precision of the method were calculated to be 3.5% and 4.0%, respectively. The newly developed method was successfully applied in real crude oil, diesel oil, gasoline, and kerosene samples. The environmental impact of the newly developed procedure was evaluated and a total score of 0.64 was obtained.
Collapse
Affiliation(s)
- Mxolisi J Kiwanuka
- Department of Chemistry, College of Science, Engineering and Technology (CSET), University of South Africa, Florida Science Campus, Johannesburg, 1709, South Africa
| | - Philiswa N Nomngongo
- Department of Chemical Sciences, Faculty of Science, University of Johannesburg, Johannesburg, South Africa
| | - Nomvano Mketo
- Department of Chemistry, College of Science, Engineering and Technology (CSET), University of South Africa, Florida Science Campus, Johannesburg, 1709, South Africa.
| |
Collapse
|
2
|
Ladeira PCC, Augusto CC, Rocha BA, Rodrigues JL, Aguiar GDFM, Batista BL. The Development of a Rapid, Cost-Effective, and Green Analytical Method for Mercury Speciation. TOXICS 2024; 12:424. [PMID: 38922104 PMCID: PMC11209405 DOI: 10.3390/toxics12060424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 05/29/2024] [Accepted: 06/08/2024] [Indexed: 06/27/2024]
Abstract
Mercury is a naturally occurring metal found in various inorganic and organic forms within the environment. Due to its high toxicity, there is global concern regarding human exposure to this element. The combination of high-performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS) is commonly used to analyze the different forms of mercury in a sample due to its high sensitivity and ability to selectively detect mercury. However, the traditional HPLC-ICP-MS methods are often criticized for their lengthy analysis times. In this study, we have refined the conventional approach by transitioning to ultra-high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (UHPLC-ICP-MS). This modification has resulted in significant reductions in runtime as well as reagent and argon usage, thereby offering a more rapid, environmentally friendly, and cost-effective method. We successfully adapted an HPLC-ICP-MS method to UHPLC-ICP-MS, achieving the analysis of Hg2+ and MeHg+ within 1 min with a mobile phase consumption of only 0.5 mL and a sample volume of 5.0 µL; this is a major advance compared to HPLC analysis with run times generally between 5 and 10 min. The method's performance was assessed by analyzing muscle and liver tissue samples (serving as reference material) from fish, demonstrating the versatility of the method in relation to different complex matrices.
Collapse
Affiliation(s)
- Patrícia Cristina Costa Ladeira
- Center for Natural and Human Sciences (CCNH), Federal University of ABC (UFABC), Santo André 09210-580, SP, Brazil; (P.C.C.L.); (C.C.A.)
| | - Caroline Cristine Augusto
- Center for Natural and Human Sciences (CCNH), Federal University of ABC (UFABC), Santo André 09210-580, SP, Brazil; (P.C.C.L.); (C.C.A.)
| | - Bruno Alves Rocha
- Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirão Preto 14040-903, SP, Brazil;
- Institute of Chemistry, Federal University of Alfenas, Alfenas 37130-001, MG, Brazil
| | - Jairo Lisboa Rodrigues
- Instituto de Ciência, Engenharia e Tecnologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Teófilo Otoni 39803-371, MG, Brazil;
| | | | - Bruno Lemos Batista
- Center for Natural and Human Sciences (CCNH), Federal University of ABC (UFABC), Santo André 09210-580, SP, Brazil; (P.C.C.L.); (C.C.A.)
| |
Collapse
|
3
|
Li N, Zhang Z, Li G. Recent advance on microextraction sampling technologies for bioanalysis. J Chromatogr A 2024; 1720:464775. [PMID: 38452559 DOI: 10.1016/j.chroma.2024.464775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 01/14/2024] [Accepted: 02/26/2024] [Indexed: 03/09/2024]
Abstract
The contents of target substances in biological samples are usually at low concentration levels, and the matrix of biological samples is usually complex. Sample preparation is considered a very critical step in bioanalysis. At present, the utilization of microextraction sampling technology has gained considerable prevalence in the realm of biological analysis. The key developments in this field focus on the efficient microextraction media and the miniaturization and automation of adaptable sample preparation methods currently. In this review, the recent progress on the microextraction sampling technologies for bioanalysis has been introduced from point of view of the preparation of microextraction media and the microextraction sampling strategies. The advance on the microextraction media was reviewed in detail, mainly including the aptamer-functionalized materials, molecularly imprinted polymers, carbon-based materials, metal-organic frameworks, covalent organic frameworks, etc. The advance on the microextraction sampling technologies was summarized mainly based on in-vivo sampling, in-vitro sampling and microdialysis technologies. Moreover, the current challenges and perspective on the future trends of microextraction sampling technologies for bioanalysis were briefly discussed.
Collapse
Affiliation(s)
- Na Li
- School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China
| | - Zhuomin Zhang
- School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China.
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China.
| |
Collapse
|
4
|
Jiao H, Bi R, Li F, Chao J, Zhang G, Zhai L, Hu L, Wang Z, Dai C, Li B. Rapid, easy and catalyst-free preparation of magnetic thiourea-based covalent organic frameworks at room temperature for enrichment and speciation of mercury with HPLC-ICP-MS. J Chromatogr A 2024; 1717:464683. [PMID: 38295741 DOI: 10.1016/j.chroma.2024.464683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/14/2024] [Accepted: 01/25/2024] [Indexed: 02/23/2024]
Abstract
The complex and cumbersome preparation of magnetic covalent organic frameworks (COFs) nanocomposites on a small scale limits their application. Herein, a rapid and easy route was employed for the preparation of magnetic thiourea-based COFs nanocomposites. COFs were coated on Fe3O4 nanoparticles at room temperature without a catalyst within approximately 30 min. This method is suitable for the large-scale preparation of magnetic adsorbent. Using the as-prepared magnetic adsorbent (Fe3O4@COF-TpTU), we developed a simple, efficient, and sensitive magnetic solid-phase extraction-high performance liquid chromatography-inductively coupled plasma-mass spectrometry (MSPE-HPLC-ICP-MS) for the enrichment and determination of mercury species, including Hg2+, methylmercury (MeHg), and ethylmercury (EtHg). The effects of the experimental parameters on the extraction efficiency, including solution pH, adsorption and desorption time, composition and volume of the elution solvent, salinity, coexisting ions, and dissolved organic matter, were comprehensively investigated. Under optimised conditions, the limits of detection in the developed method were 0.56, 0.34, and 0.47 ng L-1 with enrichment factors of 190, 195, and 180-fold for Hg2+, MeHg, and EtHg, respectively. The satisfactory spiked recoveries (97.0-103%) in real water samples and high consistency between the certified and determined values in a certified reference material demonstrate the high accuracy and reproducibility of the developed method. The as-proposed method with simple operation, high sensitivity, and excellent anti-matrix interference performance was successfully applied to the enrichment and determination of trace levels of mercury species in the natural samples with complicated matrices, such as underground water, surface water, seawater and biological samples.
Collapse
Affiliation(s)
- Heping Jiao
- Shandong Analysis and Tester Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
| | - Ruixiang Bi
- School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, China
| | - Fangli Li
- Shandong Public Health Clinic Center, Jinan 266075, China
| | - Jingbo Chao
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, Beijing 100029, China
| | - Guimin Zhang
- National Engineering and Technology Research Centre of Chirality Pharmaceutical, Lunan Pharmaceutical Group Co., Ltd., Linyi 276005, China
| | - Lihai Zhai
- National Engineering and Technology Research Centre of Chirality Pharmaceutical, Lunan Pharmaceutical Group Co., Ltd., Linyi 276005, China
| | - Ligang Hu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Zhenhua Wang
- Shandong Analysis and Tester Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China.
| | - Caifeng Dai
- Center for Reproductive Medicine, Department of Obstetrics and Gynecology, Qilu Hospital of Shandong University, Jinan, Shandong 250012, China.
| | - Bing Li
- Shandong Analysis and Tester Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China; Shandong Key Laboratory for Adhesive Materials, Advanced Materials Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China.
| |
Collapse
|
5
|
Dakova I, Yordanova T, Karadjova I. Polymeric Materials in Speciation Analysis Based on Solid-Phase Extraction. Molecules 2023; 29:187. [PMID: 38202769 PMCID: PMC10780835 DOI: 10.3390/molecules29010187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/23/2023] [Accepted: 12/26/2023] [Indexed: 01/12/2024] Open
Abstract
Speciation analysis is a relevant topic since the (eco)toxicity, bioavailability, bio (geo)chemical cycles, and mobility of a given element depend on its chemical forms (oxidation state, organic ligands, etc.). The reliability of analytical results for chemical species of elements depends mostly on the maintaining of their stability during the sample pretreatment step and on the selectivity of further separation step. Solid-phase extraction (SPE) is a matter of choice as the most suitable and widely used procedure for both enrichment of chemical species of elements and their separation. The features of sorbent material are of great importance to ensure extraction efficiency from one side and selectivity from the other side of the SPE procedure. This review presents an update on the application of polymeric materials in solid-phase extraction used in nonchromatographic methods for speciation analysis.
Collapse
Affiliation(s)
| | | | - Irina Karadjova
- Faculty of Chemistry and Pharmacy, University of Sofia “St. Kliment Ohridski”, 1, James. Bourchier Blvd.1, 1164 Sofia, Bulgaria; (I.D.); (T.Y.)
| |
Collapse
|
6
|
Chen Y, Zhang Q, Zhang L, Wang Y, Song Y, Li Y, Yin Y, Cai Y. An improved method for rapid and safe preparation and measurement of dimethylmercury using gas chromatography-atomic fluorescence spectrometry. J Chromatogr A 2023; 1712:464472. [PMID: 37924619 DOI: 10.1016/j.chroma.2023.464472] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/17/2023] [Accepted: 10/22/2023] [Indexed: 11/06/2023]
Abstract
Transformations between dimethylmercury (DMHg) and other mercury (Hg) species have been one of the critical knowledge gaps in the Hg global biogeochemical cycle due to the lack of detailed studies. The preparation and measurement of DMHg are challenging due to the high toxicity and volatility of DMHg. In this work, we invented a new DMHg generator for successfully preparing high-purity DMHg in a highly controllable and safe way. The DMHg could be spontaneously volatilized and diffused from the original preparation solution to the solution to be studied. The parameters for generating DMHg were optimized to be the pH value of 4.0 with a MeCo/Hg2+ molar ratio of 10 at 20 °C. The following measurement method of DMHg in the presence of various species of Hg was also investigated and optimized. Hg0 and DMHg could be separated effectively with the carrier gas flow rate of 15 mL min-1 and the gas chromatography column temperature of 30 °C. The interferences of Hg0, monomethylmercury and other species were excluded by systematic control experiments. A sensitive and reliable approach for quantifying trace DMHg in water was developed. Under the optimal conditions, the limits of detection for Hg0, MMHg and DMHg were 0.03, 0.002 and 0.024 ng L-1, respectively, with the relative standard deviation below 8.2%. The developed method was validated by the determination Hg species of different natural water samples. This work is expected to provide a new and safe strategy for DMHg preparation and a verified method for DMHg measurement.
Collapse
Affiliation(s)
- Yingying Chen
- Shandong Key Laboratory of Environmental Processes and Health, Qingdao Key Laboratory of Marine Pollutant Prevention, School of Environmental Science and Engineering, Shandong University, Qingdao 266237, China
| | - Qingzhe Zhang
- Shandong Key Laboratory of Environmental Processes and Health, Qingdao Key Laboratory of Marine Pollutant Prevention, School of Environmental Science and Engineering, Shandong University, Qingdao 266237, China.
| | - Lian Zhang
- Shandong Key Laboratory of Environmental Processes and Health, Qingdao Key Laboratory of Marine Pollutant Prevention, School of Environmental Science and Engineering, Shandong University, Qingdao 266237, China
| | - Yingjun Wang
- Shandong Key Laboratory of Environmental Processes and Health, Qingdao Key Laboratory of Marine Pollutant Prevention, School of Environmental Science and Engineering, Shandong University, Qingdao 266237, China
| | - Yue Song
- Shandong Key Laboratory of Environmental Processes and Health, Qingdao Key Laboratory of Marine Pollutant Prevention, School of Environmental Science and Engineering, Shandong University, Qingdao 266237, China
| | - Yanbin Li
- Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao 266100, China
| | - Yongguang Yin
- Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Yong Cai
- Shandong Key Laboratory of Environmental Processes and Health, Qingdao Key Laboratory of Marine Pollutant Prevention, School of Environmental Science and Engineering, Shandong University, Qingdao 266237, China; Department of Chemistry & Biochemistry, Florida International University, Miami, FL 33199, United States.
| |
Collapse
|
7
|
Pasupuleti RR, Huang Y. Recent applications of atomic spectroscopy coupled with magnetic solid‐phase extraction techniques for heavy metal determination in environmental samples: A review. J CHIN CHEM SOC-TAIP 2023. [DOI: 10.1002/jccs.202300029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2023]
Affiliation(s)
- Raghavendra Rao Pasupuleti
- Department of Medical Laboratory Science and Biotechnology Kaohsiung Medical University Kaohsiung Taiwan
| | - Yeou‐Lih Huang
- Department of Medical Laboratory Science and Biotechnology Kaohsiung Medical University Kaohsiung Taiwan
- Department of Laboratory Medicine, Kaohsiung Medical University Hospital Kaohsiung Medical University Kaohsiung Taiwan
- Graduate Institute of Medicine Kaohsiung Medical University Kaohsiung Taiwan
- Research Center for Precision Environmental Medicine Kaohsiung Medical University Kaohsiung Taiwan
- Department of Chemistry National Sun Yat‐sen University Kaohsiung Taiwan
| |
Collapse
|
8
|
Du J, Liu K, Liu J, Zhao D, Bai Y. Development of a novel lateral flow immunoassay based on Fe3O4@MIL-100(Fe) for visual detection of Listeria monocytogenes. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2023. [DOI: 10.1007/s11694-023-01900-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/19/2023]
|
9
|
Gao S, Sun L, Zhou X, Zhu S, Liu H, Zhao XE. Simultaneous and dynamic measurement of Schisandrol A changes in rat blood and brain and its comparative pharmacokinetic study in control and Parkinson's disease rats by dual-probe in vivo microdialysis. J Chromatogr A 2023; 1695:463950. [PMID: 37003077 DOI: 10.1016/j.chroma.2023.463950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 03/09/2023] [Accepted: 03/24/2023] [Indexed: 03/29/2023]
Abstract
Schisandrol A (SchA) is the main active ingredient of Schisandra chinensis (Turcz.) Baill., which is a famous traditional Chinese herbal medicine. SchA can penetrate the blood-brain barrier and has a significant neuroprotective effect. A group of multiplexed stable isotope mass tags (MSIMTs, m/z 332, 338, 346, 349, 351, 354, 360, 363, 374 and 377) were synthesized to perform multiplexed stable isotope labeling derivatization (MSILD) of SchA in rat microdialysates and standards. A new magnetic molecularly imprinted polymer was prepared using MSIMT-375-SchA as dummy template. All the 10-plexed derivatives of MSIMTs-SchA can be efficiently and selectively enriched and purified using this adsorbent by magnetic dispersive solid phase extraction (MDSPE) before ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) analysis. It should be pointed out that the MSIMT-346-SchA standard derivative was used as internal standard in the process of MDSPE and UHPLC-MS/MS. On these bases, 9 different rat microdialysate samples can be determined by UHPLC-MS/MS in a single run. The utilization of MSIMTs significantly increased the sensitivity, accuracy, selectivity and analysis throughput. Under the optimized conditions, satisfactory linearity (R2> 0.987), limit of detection (LODs, 0.15-0.26 pg/mL) and lower limit of quantitative (LLOQ, 0.8-2.0 pg/mL) were obtained. Intra- and inter-day precisions were in the range of 2.2% -12.5%, and recoveries 94.2% -106.2%. The matrix effects were very low, and the average derivatization efficiency of 10-plex MSIMTs to SchA was as high as 97.8%. Using the developed dual-probe in vivo microdialysis sampling technique, the proposed analytical method has been applied for comparative pharmacokinetics of SchA in the brain and blood of control and Parkinson's disease (PD) rats.
Collapse
|
10
|
A novel modified magnetic Co-MOF-71 for magnetic solid phase extraction of Hg(II) ions in food samples. RESEARCH ON CHEMICAL INTERMEDIATES 2023. [DOI: 10.1007/s11164-023-04976-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
|
11
|
Tian W, Liu Y, Wang S, Ye J, Liu H, Wang Y, Zhou M. Automated and Rapid Easy-to-Use Magnetic Solid-Phase Extraction System for Five Heavy Metals in Cereals and Feeds. Foods 2022; 11:foods11243944. [PMID: 36553685 PMCID: PMC9778536 DOI: 10.3390/foods11243944] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/01/2022] [Accepted: 12/05/2022] [Indexed: 12/12/2022] Open
Abstract
A rapid, accurate, and ecofriendly pretreatment plays an extremely important role prior to ICP-MS for heavy metal analysis. In order to improve the pretreatment efficiency, a high-throughput and automatic magnetic solid-phase extraction of five heavy metals (Cd, Pb, Mn, Cu, and Zn) was carried out by a magnet-controlled pretreatment system with an ecofriendly diluted acid as an extracting agent and carboxyl-functionalized magnetic beads as a pretreatment material. Key conditions, including the pH, adsorption time, and eluent solution, were optimized. The time for purification and enrichment was only 8 min. The adsorption capacities of the carboxyl-functionalized magnetic beads were in the range of 152~426 mg g-1. The preconcentration factor of Cu was 40, and others were 200. In the optimal conditions, the limits of detection for Mn, Zn, Cd, Cu, and Pb by ICP-MS were 3.84, 2.71, 0.16, 11.54, and 6.01 ng L-1, respectively. The percentage recoveries were in the range of 80~110%, and the relative standard deviations were less than 3%. The developed method was in good agreement with traditional standard microwave digestion. Additionally, the designed system could simultaneously process up to 24 samples within 22 min, reducing the time to less than 1 min/sample. Thus, the proposed auto-MSPE-ICP-MS method was successfully applied to analyze five heavy metals in cereals and feeds with a simple operation and high precision, safety, and reliability.
Collapse
Affiliation(s)
- Wei Tian
- Academy of National Food and Strategic Reserves Administration, Beijing 100037, China
| | - Yonglin Liu
- School of Environmental and Municipal Engineering, Qingdao University of Technology, Qingdao 266525, China
| | - Songxue Wang
- Academy of National Food and Strategic Reserves Administration, Beijing 100037, China
| | - Jin Ye
- Academy of National Food and Strategic Reserves Administration, Beijing 100037, China
| | - Hongmei Liu
- Academy of National Food and Strategic Reserves Administration, Beijing 100037, China
| | - Yue Wang
- Academy of National Food and Strategic Reserves Administration, Beijing 100037, China
| | - Minghui Zhou
- Academy of National Food and Strategic Reserves Administration, Beijing 100037, China
- Correspondence:
| |
Collapse
|
12
|
One-pot fabrication of functional magnetic adsorbent for efficient capture of mercury species in aqueous samples prior to HPLC analysis. J Chromatogr A 2022; 1685:463622. [DOI: 10.1016/j.chroma.2022.463622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 10/26/2022] [Accepted: 10/28/2022] [Indexed: 11/06/2022]
|
13
|
Zhu N, Xu J, Ma Q, Geng Y, Li L, Liu S, Liu S, Wang G. Rhodamine-Based Fluorescent Probe for Highly Selective Determination of Hg 2. ACS OMEGA 2022; 7:29236-29245. [PMID: 36033650 PMCID: PMC9404173 DOI: 10.1021/acsomega.2c03336] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 08/02/2022] [Indexed: 06/15/2023]
Abstract
The determination of mercuric ions (Hg2+) in environmental and biological samples has attracted the attention of researchers lately. In the present work, a novel turn-on Hg2+ fluorescent probe utilizing a rhodamine derivative had been constructed and prepared. The probe could highly sensitively and selectively sense Hg2+. In the presence of excessive Hg2+, the probe displayed about 52-fold fluorescence enhancement in 50% H2O/CH3CH2OH (pH, 7.24). In the meantime, the colorless solution of the probe turned pink upon adding Hg2+. Upon adding mercuric ions, the probe interacted with Hg2+ and formed a 1:1 coordination complex, which had been the basis for recognizing Hg2+. The probe displayed reversible dual colorimetric and fluorescence sensing of Hg2+ because rhodamine's spirolactam ring opened upon adding Hg2+. The analytical performances of the probe for sensing Hg2+ were also studied. When the Hg2+ concentration was altered in the range of 8.0 × 10-8 to 1.0 × 10-5 mol L-1, the fluorescence intensity showed an excellent linear correlation with Hg2+ concentration. A detection limit of 3.0 × 10-8 mol L-1 had been achieved. Moreover, Hg2+ in the water environment and A549 cells could be successfully sensed by the proposed probe.
Collapse
Affiliation(s)
- Nannan Zhu
- School
of Pharmacology, Henan University of Chinese
Medicine, Zhengzhou 450046, P. R. China
| | - Junhong Xu
- Department
of Dynamical Engineering, North China University
of Water Resources and Electric Power, Zhengzhou 450011, P. R. China
| | - Qiujuan Ma
- School
of Pharmacology, Henan University of Chinese
Medicine, Zhengzhou 450046, P. R. China
| | - Yang Geng
- Department
of Pharmacy, Zhengzhou Railway Vocational
and Technical College, Zhengzhou 451460, P. R. China
| | - Linke Li
- School
of Pharmacology, Henan University of Chinese
Medicine, Zhengzhou 450046, P. R. China
| | - Shuzhen Liu
- School
of Pharmacology, Henan University of Chinese
Medicine, Zhengzhou 450046, P. R. China
| | - Shuangyu Liu
- School
of Pharmacology, Henan University of Chinese
Medicine, Zhengzhou 450046, P. R. China
| | - Gege Wang
- School
of Pharmacology, Henan University of Chinese
Medicine, Zhengzhou 450046, P. R. China
| |
Collapse
|
14
|
Zhang Y, Wu Y, Su L, Zhu C, Wu X. An ultrasensitive electrochemical sensor based on in situ synthesized manganese dioxide/gold nanoparticles nanocomposites for rapid detection of methylmercury in foodstuffs. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2329-2336. [PMID: 35647814 DOI: 10.1039/d2ay00417h] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The inclusion of methylmercury (CH3Hg+) in the environment and food chain has aroused wide concern due to its high neurotoxicity and cumulative effects. Herein, a highly sensitive electrochemical sensor based on manganese dioxide (MnO2)/gold nanoparticles (AuNPs) composites is fabricated for CH3Hg+ detection in food. The MnO2/AuNPs nanocomposites were synthesized in situ on the surface of a glassy carbon electrode by an electrodeposition method and were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The resulting MnO2/AuNPs modified electrode exhibited a large active surface area, enhanced conductivity and excellent electrocatalytic activity toward CH3Hg+ due to the synergistic effect of MnO2 and AuNPs. Square wave anodic stripping voltammetry (SWASV) was used as the sensing technique for CH3Hg+, and the stripping peak current showed a good linear relationship with CH3Hg+ concentration in the range of 0.7-15 μg L-1 with a detection limit of 0.051 μg L-1. Besides, the interference from Hg2+ associated with CH3Hg+ detection can be avoided by the addition of diethylene triamine pentaacetic acid (DTPA). The as-prepared sensor was applied to detect CH3Hg+ in various food samples with satisfactory recoveries, thus providing a promising platform for rapid screening of methylmercury residues.
Collapse
Affiliation(s)
- Yi Zhang
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, P.R. China.
| | - Yanqing Wu
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, P.R. China.
| | - Lishen Su
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, P.R. China.
| | - Chunlin Zhu
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, P.R. China.
| | - Xiaoping Wu
- Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), College of Chemistry, Fuzhou University, Fuzhou 350116, P.R. China.
| |
Collapse
|
15
|
Barzin M, Pooladi M. A novel post-synthetic modification of magnetic MIL-101(Cr) metal–organic framework with 1,8-diaminonaphthalene chelator and its utilization for separation/determination of cadmium and nickel in food samples. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02265-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
16
|
Alvand N, Baghdadi M, Alimoradi M, Marjani A, Isfahani TM. Metal-Phase Microextraction (MPME) as a Novel Solvent-Free and Green Sample Preparation Technique: Determination of Cadmium in Infant Formula and Real Water Samples. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-022-02259-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|