1
|
Huang B, Chen M, Wang J, Zhang X. Advances in zirconia-based dental materials: Properties, classification, applications, and future prospects. J Dent 2024; 147:105111. [PMID: 38866229 DOI: 10.1016/j.jdent.2024.105111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 06/04/2024] [Accepted: 06/06/2024] [Indexed: 06/14/2024] Open
Abstract
OBJECTIVES Zirconia (ZrO2) ceramics are widely used in dental restorations due to their superior mechanical properties, durability, and ever-improving translucency. This review aims to explore the properties, classification, applications, and recent advancements of zirconia-based dental materials, highlighting their potential to revolutionize dental restoration techniques. STUDY SELECTION, DATA AND SOURCES The most recent literature available in scientific databases (PubMed and Web of Science) reporting advances of zirconia-based materials within the dental field is thoroughly examined and summarized, covering the major keywords "dental zirconia, classification, aesthetic, LTD, applications, manufacturing, surface treatments". CONCLUSIONS An exhaustive overview of the properties, classifications, and applications of dental zirconia was presented, alongside an exploration of future prospects and potential advances. This review highlighted the importance of addressing challenges such as low-temperature degradation resistance and optimizing the balance between mechanical strength and translucency. Also, innovative approaches to improve the performances of zirconia as dental material was discussed. CLINICAL SIGNIFICANCE This review provides a better understanding of zirconia-based dental biomaterials for dentists, helping them to make better choice when choosing a specific material to fabricate the restorations or to place the implant. Moreover, new generations of zirconia are still expected to make progress on key issues such as the long-term applications in dental materials while maintaining both damage resistance and aesthetic appeal, defining the directions for future research.
Collapse
Affiliation(s)
- Bo Huang
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China
| | - Mengbing Chen
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China
| | - Jian Wang
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China.
| | - Xin Zhang
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China.
| |
Collapse
|
2
|
Kasem AT, Abo-Madina M, Al-Zordk W. Influence of retainer design and number of inlay boxes on the biomechanical behavior of zirconia cantilever resin bonded fixed dental prosthesis. J ESTHET RESTOR DENT 2024; 36:652-662. [PMID: 37737460 DOI: 10.1111/jerd.13130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 08/23/2023] [Accepted: 08/25/2023] [Indexed: 09/23/2023]
Abstract
OBJECTIVES The development of dental adhesives with enhanced bond strength has assisted minimally invasive dentistry. The aim of this study was to evaluate the fracture load and stress distribution pattern of two retainer designs for posterior cantilever resin bonded fixed dental protheses (RBFDPs). MATERIALS AND METHODS Forty human mandibular molars were divided into two groups according to the retainer design; lingual coverage (LC) and occlusal coverage (OC) retainers. Each main group was then divided according to the number of inlay boxes (n = 10); one inlay and two inlay boxes. High translucency (3Y) zirconia was used to manufacture all restorations, and a dual-polymerizing adhesive resin cement was used for bonding. All specimens underwent 10,000 cycles of thermocycling (5-55°C), 240,000 cycles of dynamic loading (50 N, descending speed v = 30 mm/second, frequency = 1.6 Hz), and failure load test. Both one-way and two-way ANOVA tests were used to analyze the data. The four models included in the in-vitro study are part of the finite element analysis (FEA). When the restorations failed, maximal principal stress values on restorations, enamel, dentin, and luting resin were investigated. RESULTS A statistically significant (p = 0.018) higher failure load was recorded for OC1 (627.00 ± 153.4 N) than the other groups; (548.0 ± 75.6 N, 521.20 ± 11.3 N, and 509.20 ± 14.9 N for LC1, LC2, and OC2, respectively). With regard to failure mode, one inlay box designs showed more favorable failure pattern than those of two inlay boxes. FEA showed higher stress magnitude transmitted to the tooth structure in models LC2 and OC2. CONCLUSIONS Lingual coverage and occlusal coverage retainers are promising designs capable to withstand the normal occlusal force for cantilever RBFDP in premolar area. The use of two inlay boxes decreased the fracture load of the two retainer designs and increased the stress transmitted to the tooth and resulted in high incidence of catastrophic failure. CLINICAL SIGNIFICANCE Monolithic high translucent zirconia RBFDP could be considered as a viable treatment option to substitute missing posterior tooth, with improved esthetics and biocompatibility.
Collapse
Affiliation(s)
- Ammar T Kasem
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Manal Abo-Madina
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
- Fixed Prosthodontics Department, Faculty of Dentistry, Delta University for Science and Technology, Mansoura, Egypt
| | - Walid Al-Zordk
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
3
|
Bömicke W, Boisserée P, Rammelsberg P, Rues S. Initial damage and failure load of zirconia-ceramic and metal-ceramic posterior cantilever fixed partial dentures. Clin Oral Investig 2024; 28:94. [PMID: 38221600 PMCID: PMC10788321 DOI: 10.1007/s00784-024-05501-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 01/07/2024] [Indexed: 01/16/2024]
Abstract
OBJECTIVES The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading configurations. MATERIALS AND METHODS Eight test groups with anatomically congruent CFPDs (n = 8/group) were fabricated, differing in CFPD material/support structure/loading direction (load applied via steel ball (Ø 6 mm) 3 mm from the distal end of the pontic for axial loading with a 2-point contact on the inner cusp ridges of the buccal and oral cusps and 1.3 mm below the oral cusp tip for 30° oblique loading): (1) monolithic zirconia/CoCr abutment teeth/axial, (2) monolithic zirconia/CoCr abutment teeth/oblique, (3) partially veneered zirconia/CoCr abutment teeth/axial, (4) partially veneered zirconia/CoCr abutment teeth/oblique, (5) completely veneered zirconia/CoCr abutment teeth/axial, (6) completely veneered CoCr/CoCr abutment teeth/axial (control group), (7) partially veneered zirconia/implants/axial, and (8) partially veneered zirconia/natural teeth/axial. Restorations were artificially aged before failure testing. Statistical analysis was conducted using one-way ANOVA and Tukey post hoc tests. RESULTS Mean failure loads ranged from 392 N (group 8) to 1181 N (group 1). Axially loaded monolithic zirconia CFPDs (group 1) and controls (group 6) showed significantly higher failure loads. Oblique loading significantly reduced failure loads for monolithic zirconia CFPDs (group 2). Initial damage was observed in all groups except monolithic zirconia groups, and fractography revealed design flaws (sharp edges at the occlusal boundary of the veneering window) in partially veneered zirconia CFPDs. CONCLUSIONS Monolithic zirconia CFPDs might be a viable alternative to completely veneered CoCr CFPDs in terms of fracture load. However, oblique loading of monolithic zirconia CFPDs should be avoided in clinical scenarios. Design improvements are required for partially veneered zirconia CFPDs to enhance their load-bearing capacity. CLINICAL RELEVANCE Monolithic zirconia may represent a viable all-ceramic alternative to the established metal-ceramic option for CFPD fabrication. However, in daily clinical practice, careful occlusal adjustment and regular monitoring should ensure that oblique loading of the cantilever is avoided.
Collapse
Affiliation(s)
- Wolfgang Bömicke
- Department of Prosthetic Dentistry, University Hospital Heidelberg, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | | | - Peter Rammelsberg
- Department of Prosthetic Dentistry, University Hospital Heidelberg, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Stefan Rues
- Department of Prosthetic Dentistry, University Hospital Heidelberg, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
4
|
Klotz AL, Halfmann J, Rues S, Bömicke W, Rammelsberg P, Zenthöfer A. Fracture Resistance of Posterior Tooth-Supported Cantilever Fixed Dental Prostheses of Different Zirconia Generations and Framework Thicknesses: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2024; 17:263. [PMID: 38204115 PMCID: PMC10779861 DOI: 10.3390/ma17010263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/20/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024]
Abstract
The rehabilitation of free-end situations is a frequent indication in prosthetic dentistry. Cantilever fixed dental prostheses (cFDPs) made of 1st and 2nd generation zirconia are one treatment option. Due to a unique gradient technology, combinations of different zirconium dioxide generations are thus feasible in one restoration. However, data about these materials are rare. The purpose of this study was therefore to investigate the fracture resistance and fracture modes of tooth-supported cFDPs fabricated from different zirconia materials (gradient technology) and different framework thicknesses. A total of 40 cFDPs were fabricated using the CAD/CAM approach and belonged to five test groups. The different groups differed in the yttria content, the proportion of the tetragonal/cubic phases, or in wall thickness (0.7 mm or 1 mm). After completion, the cFDPs were subjected to thermal cycling and chewing simulation (1.2 × 106 load cycles, 108 N load). Afterwards, cFDPs were statically loaded until fracture in a universal testing machine. A non-parametric ANOVA was compiled to determine the possible effects of group membership on fracture resistance. In addition, post-hoc Tukey tests were used for bivariate comparisons. The mean fracture loads under axial load application ranged from 288 to 577 N. ANOVA detected a significant impact of the used material on the fracture resistances (p < 0.001). Therefore, the use of cFDPs fabricated by gradient technology zirconia may not be unreservedly recommended for clinical use, whereas cFPDs made from 3Y-TZP exhibit fracture resistance above possible masticatory loads in the posterior region.
Collapse
Affiliation(s)
- Anna-Luisa Klotz
- Department of Prosthodontics, Dental School, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; (J.H.); (S.R.); (W.B.); (P.R.); (A.Z.)
| | | | | | | | | | | |
Collapse
|
5
|
Kasem AT, Abo-Madina M, Tribst JPM, Al-Zordk W. Cantilever resin-bonded fixed dental prosthesis to substitute a single premolar: Impact of retainer design and ceramic material after dynamic loading. J Prosthodont Res 2023; 67:595-602. [PMID: 36775338 DOI: 10.2186/jpr.jpr_d_22_00226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
PURPOSE To evaluate the influence of retainer design and ceramic materials on the durability of minimally invasive cantilever resin-bonded fixed dental prostheses (RBFDPs) after artificial aging. METHODS One hundred caries-free human mandibular molars were prepared as abutments for all-ceramic cantilevered fixed dental prostheses using the following retainer designs: One wing (OW), Two wings (TW), Inlay ring (IR), Lingual coverage (LC), and Occlusal coverage (OC). Two ceramic materials were used: monolithic high translucent zirconia(z) and zirconia-reinforced lithium disilicate (ZLS2) (n=10). All restorations were adhesively bonded with resin cement. The thermocycling of the specimens were performed between 5°C and 55°C for 10,000 cycles and then exposed to 240.000 cycles of dynamic loading on a chewing simulator. All surviving specimens were loaded onto the pontic until failure using a universal testing machine. RESULTS The mean failure load ranged from 124.00 to 627.00 N for the zirconia groups and from 133.30 to 230.00 N for the ZLS2 groups. Regarding the materials, a significantly higher failure load was recorded in the zirconia groups than in the ZLS2 groups (P<0.001), except for OW (P=0.748). Regarding the retainer designs, a significant different failure load was recorded between the different designs except for IR and LC in the zirconia groups, IR and OC, OW and TW, and TW and LC in the ZLS2 groups (P<0.001). CONCLUSIONS Zirconia IR, LC, and OC can be used as cantilever RBFDP in the premolar region. The fracture resistance of the ZLS2 design was below the normal bite force and should not be recommended as the first option.
Collapse
Affiliation(s)
- Ammar T Kasem
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Manal Abo-Madina
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
- Fixed Prosthodontics Department, Faculty of Dentistry, Delta University for Science and Technology, Mansoura, Egypt
| | - João Paulo M Tribst
- Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, the Netherlands
| | - Walid Al-Zordk
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
6
|
Ni J, Xu L, Lin Y, Lai D, Huang X. Effects on different full-coverage designs and materials of crack propagation in first mandibular molar: an extended finite element method study. Front Bioeng Biotechnol 2023; 11:1222060. [PMID: 37650043 PMCID: PMC10464904 DOI: 10.3389/fbioe.2023.1222060] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 08/07/2023] [Indexed: 09/01/2023] Open
Abstract
Objectives: This study aims to investigate the biomechanical properties of fracture resistance in cracked teeth using five different full-coverage restorations made of three different materials. Materials and Methods: A 3D model of a mandibular first molar was created to design five different full-coverage repair models: crown, crown with composite resin filling inside, occlusal veneer, occlusal veneer with composite resin filling inside and onlay. These repair models were fabricated using three different materials, namely, zirconia, lithium disilicate (LDS), and a hybrid polymer-infiltrated ceramic network material (PIC). In total, 15 repair models were tested using the extended finite element method (XFEM), with an occlusal load of 5000 N applied slowly to the occlusal surface of the restoration. The analysis of stress distribution in the restoration and dentin crack line was conducted to measure and record the crack initial load on the restoration and dentin. Results: The results showed that restorations on the occlusal surface significantly improved crack resistance, with zirconia exhibiting superior fracture resistance among the materials tested. Restorations of crown with composite resin filling inside demonstrated the highest resistance to fracture, while occlusal veneers showed the lowest. MPS concentration was observed at the interface between the restoration and dentin and at the root bifurcation, with the highest values at the top of crack development. Dentin covered by oxidized restorations had the highest displacement, while PIC restorations exhibited the lowest. Pulp analysis revealed selective MPS concentration and strain patterns in models with zirconia restorations and onlay, with pronounced pulp displacement in zirconia restorations and onlay. Enamel analysis indicated larger MPS values and displacements in zirconia restoration models and onlay, with higher strain in onlay. Restoration played a crucial role in protecting the tooth, with crack propagation initial loads in dentin surpassing restorations in experimental groups. Conclusion: This study confirms that full-coverage restorations significantly increased the fracture resistance of cracked teeth, with zirconia restorations significantly protecting the underlying cracked tooth. Elimination of fracture lines in the restoration design can improve fracture resistance in cracked teeth. The findings have implications for dental prosthetic design and clinical practice.
Collapse
Affiliation(s)
| | | | | | | | - Xiaohong Huang
- Department of Stomatology, The First Affiliated Hospital, Fujian Medical University, Fuzhou, China
| |
Collapse
|
7
|
Kasem AT, Elsherbiny AA, Abo-Madina M, Tribst JPM, Al-Zordk W. Biomechanical behavior of posterior metal-free cantilever fixed dental prostheses: effect of material and retainer design. Clin Oral Investig 2023; 27:2109-2123. [PMID: 36456895 PMCID: PMC10160170 DOI: 10.1007/s00784-022-04813-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 11/27/2022] [Indexed: 12/03/2022]
Abstract
OBJECTIVE To study the fracture resistance and stress distribution pattern of translucent zirconia and fiber-reinforced composite cantilever resin-bonded fixed dental prostheses (RPFDPs) with two retainer designs. MATERIALS AND METHODS Forty human mandibular molars were divided into two groups according to the retainer design. The restorations included a premolar pontic and 2 retainer designs: (D1) inlay ring retainer and (D2) lingual coverage retainer. Each main group was then divided according to the material used (n = 10): zirconia (Z) or fiber-reinforced composite (FRC) (F). Restorations were cemented using dual polymerizing adhesive luting resin. All specimens were thermo-cycled (5-55 °C for 10,000 cycles), then subjected to dynamic loading (50 N, 240,000, and 1.6 Hz) and fracture resistance test. The finite element analysis includes the two models of retainer designs used in the in vitro test. Modified von Mises stress values on enamel, dentin, luting resin, and restorations were examined when the restorations failed. RESULTS A significantly higher failure load was recorded for zirconia groups (505.00 ± 61.50 and 548.00 ± 75.63 N for D1Z and D2Z, respectively) than for FRC groups (345.00 ± 42.33 and 375.10 ± 53.62 N for D1F and D2F, respectively) (P = 0.001). With regard to failure mode, D2 showed a more favorable failure pattern than D1. Model D2 resulted in lower stresses in tooth structure than model D1, and zirconia transmitted more stresses to the tooth structure than FRC. CONCLUSIONS The lingual coverage retainer (D2) enhanced the biomechanical performance of the restoration/tooth complex. Considering the failure mode and tooth stress, FRC is a promising treatment option when constructing a cantilever RPFDP. CLINICAL RELEVANCE Dentists should be aware of the biomechanical behavior during the selection of the material and for the replacement of a single missing mandibular premolar tooth with minimally invasive RBFDP.
Collapse
Affiliation(s)
- Ammar T Kasem
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
| | - Abdallah Ahmed Elsherbiny
- Production Engineering and Mechanical Design Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt
| | - Manal Abo-Madina
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
- Fixed Prosthodontics Department, Faculty of Dentistry, Delta University for Science and Technology, Mansoura, Egypt
| | - João Paulo M Tribst
- Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit Van Amsterdam and Vrije Universiteit, Amsterdam, Noord-Holland, the Netherlands
| | - Walid Al-Zordk
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
8
|
Kasem AT, Elsherbiny AA, Abo-Madina M, Tribst JPM, Al-Zordk W. Effect of different designs of minimally invasive cantilever resin-bonded fixed dental prostheses replacing mandibular premolar: Long-term fracture load and 3D finite element analysis. J Prosthodont 2023; 32:e41-e51. [PMID: 36502276 DOI: 10.1111/jopr.13626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 11/24/2022] [Accepted: 11/30/2022] [Indexed: 12/14/2022] Open
Abstract
PURPOSE To evaluate the fracture load and stress magnitude of different retainer designs of minimally invasive cantilever resin-bonded fixed dental prostheses (RBFDPs) after artificial aging. MATERIALS AND METHODS Fifty caries-free human mandibular molars were prepared as abutments for cantilever fixed dental prostheses using different retainer designs: one wing (OW), two wings (TW), inlay ring (IR), lingual coverage (LC), and occlusal coverage (OC). Computer-aided design and computer-aided manufacturing were used for milling the RBFDPs using fiber-reinforced composite (FRC), and the restorations were adhesively bonded. The specimens were then subjected to thermomechanical aging and loaded until failure. The 3D finite element analysis (FEA) was performed with five models of retainer designs similar to the in vitro test. Modified von Mises stress values on enamel, dentine, luting resin, and restorations were examined. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests (p < 0.001). RESULTS A statistically significant difference (p < 0.001) was found between all groups except between IR and LC and between OW and TW designs, with the highest mean failure load detected for OC (534.70 N) and the lowest detected for OW (129.80 N). With regard to failure mode, OW, TW, and LC showed more incidences of favorable failure patterns than IR and OC designs. FEA showed that FRC transmitted low stresses in tooth structure and high stresses to the luting resin. CONCLUSIONS LC and OC designs can be used to design cantilever RBFDPs in premolar area. IR design transmitted more stresses to the tooth structure and resulted in 30% catastrophic failure. OW and TW were below the normal occlusal force and should be carefully used.
Collapse
Affiliation(s)
- Ammar T Kasem
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Abdallah Ahmed Elsherbiny
- Production Engineering and Mechanical Design Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt
| | - Manal Abo-Madina
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.,Fixed Prosthodontics Department, Faculty of Dentistry, Delta University for Science and Technology, Mansoura, Egypt
| | - João Paulo M Tribst
- Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Walid Al-Zordk
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
9
|
Khaled M, Sabet A, Ebeid K, Salah T. Effect of Different Preparation Depths for an Inlay-Retained Fixed Partial Denture on the Accuracy of Different Intraoral Scanners: An In Vitro Study. J Prosthodont 2021; 31:601-605. [PMID: 34837276 DOI: 10.1111/jopr.13457] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/20/2021] [Indexed: 11/30/2022] Open
Abstract
PURPOSE The aim was to evaluate the effect of different preparation depths for inlay-retained fixed partial dentures on the accuracy of intraoral scanners. MATERIALS AND METHODS Tooth preparations for two inlay-retained fixed partial dentures were done and divided according to depth of the preparation. Group A: 2mm pulpal floor depth, 3mm gingival floor depth and Group B: 3mm pulpal floor depth, 4mm gingival floor depth. The CEREC Omnicam4.4.4, Omnicam4.6.2. Trios3 and Medit i500 intraoral scanners were used in this study. Tooth preparations were scanned by each scanner 10 times. The STL files obtained from the intraoral scanners were compared to the reference models (trueness) and within each test group (precision) using a 3D comparison software. Data were then statistically analyzed. RESULTS Regarding trueness, two-way ANOVA revealed significant differences between the different types of scanners (p<0.001) (Omnicam4.4.4: 65.09 ±2.87 Omnicam4.6.1: 52.73 ±3.31 Medit i500: 58.45 ±2.63 Trios 3: 41.79 ±4.42). Preparation depth had no significant influence on the trueness (p = 0.083). For precision two-way ANOVA revealed significant differences between the different types of scanners (p<0.001). Preparation depth had no significant influence on the precision (p = 0.111). Statistically significant interactions were found between the different variables. CONCLUSIONS The depth of preparation did not have an influence on the accuracy of different scanners. However, the type of scanner influenced the accuracy of digital impressions with Trios3 showing the highest accuracy. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Mohamed Khaled
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Ahmed Sabet
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.,Department of Fixed Prosthodontics, Faculty of Dentistry, British University in Egypt, Cairo, Egypt
| | - Kamal Ebeid
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Tarek Salah
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| |
Collapse
|
10
|
Dal Piva AMO, Tribst JPM, Saavedra GSFA, Souza ROA, de Melo RM, Borges ALS, Özcan M. Short communication: Influence of retainer configuration and loading direction on the stress distribution of lithium disilicate resin-bonded fixed dental prostheses: 3D finite element analysis. J Mech Behav Biomed Mater 2019; 100:103389. [PMID: 31398693 DOI: 10.1016/j.jmbbm.2019.103389] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 08/01/2019] [Accepted: 08/04/2019] [Indexed: 11/19/2022]
Abstract
The present study elucidates the mechanical performance of different designs of resin-bonded fixed dental prostheses made of lithium disilicate simulating masticatory loads of anterior or canine guidance. A three-dimensional model of maxilla was constructed containing central incisor and canine teeth, with edentulous space of the lateral incisor. Three designs of prosthesis were created: retained in central incisor (1-I), retained in canine (1-C) and fixed in both teeth (2-IC). The computational analysis was performed for load in canine and central incisor separately (100N, 45°). The tensile and shear stresses were calculated for the resin-bonded fixed dental prosthesis, bonding surface of each retainer and cement layer using 3D finite element analysis. The 20 highest stress values were analyzed using two-way ANOVA and post-hoc Tukey test, all with α = 5%. The computational analysis showed that 2-retainer resin-bonded fixed dental prosthesis presented the worst prognosis regardless of the mandibular movement. ANOVA showed that Mandibular movement*Retainer interaction influenced on the tensile and shear stresses values (p < 0.01). Higher stresses were observed in the connector region for all groups (13-82.2 MPa; 11-70.2 MPa). In order to reduce the stress concentration in the resin-bonded fixed dental prosthesis and the retainer made of lithium disilicate, the occlusion may serve as the selection criteria of the unitary abutment for better sustainability.
Collapse
Affiliation(s)
- Amanda M O Dal Piva
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Brazil; Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan #3004, 1081 LA, Amsterdam, Noord-Holland, the Netherlands.
| | - João P M Tribst
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Brazil; Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan #3004, 1081 LA, Amsterdam, Noord-Holland, the Netherlands.
| | - Guilherme S F A Saavedra
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Engenheiro Francisco José Longo Avenue, 777, 12245-000, São José dos Campos/SP, Brazil.
| | - Rodrigo O A Souza
- Department of Restorative Dentistry, Division of Prosthodontics, Federal University of Rio Grande do Norte (UFRN), Natal, Brazil.
| | - Renata M de Melo
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Engenheiro Francisco José Longo Avenue, 777, 12245-000, São José dos Campos/SP, Brazil.
| | - Alexandre L S Borges
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Engenheiro Francisco José Longo Avenue, 777, 12245-000, São José dos Campos/SP, Brazil.
| | - Mutlu Özcan
- University of Zürich, Dental Materials Unit, Center for Dental and Oral Medicine, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science, Rämistrasse 71, 8006, Zurich, Switzerland.
| |
Collapse
|
11
|
Tribst JPM, Dal Piva AMO, de Melo RM, Borges ALS, Bottino MA, Özcan M. Short communication: Influence of restorative material and cement on the stress distribution of posterior resin-bonded fixed dental prostheses: 3D finite element analysis. J Mech Behav Biomed Mater 2019; 96:279-284. [PMID: 31077955 DOI: 10.1016/j.jmbbm.2019.05.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 05/01/2019] [Accepted: 05/03/2019] [Indexed: 11/24/2022]
Abstract
The goal of this study was to compare the mechanical response of resin-bonded fixed dental prosthesis (RBFDP) made in zirconia, metal, lithium disilicate and composite resin cemented using resin cements with different elastic modulus. For the finite element analysis, a three-dimensional model of partial right maxilla was used to create a model with edentulous space in the second premolar and the cavity's preparation on the first pre-molar and first molar to receive a RBFDP. The model was imported to the analysis software in which they were divided into mesh composed by nodes (371,101) and tetrahedral elements (213,673). Each material was considered isotropic, elastic and homogeneous. No-separation contacts were considered between restoration/resin cement and resin cement/tooth. For all other structures the contacts were considered ideal. The model fixation occurred at the base of the bone and an axial load of 300 N was applied on the pontic occlusal surface. To simulate polymerization shrinkage effects on the cement, the thermal expansion approach was used. The displacement and maximum principal stress (in MPa) were selected as failure criteria. The prosthesis made in composite resin showed higher displacement, while in zirconia showed higher stress concentration. Tensile stress between restoration/cement, cement and cement/cavity was directly proportional to the restorative material's elastic modulus. The more rigid cement increases the tensile zones in the cement layer but decreases the stress between prosthesis and cement. The molar cavity showed higher stress concentration between restoration/cement than the preparation in the pre-molar tooth. The use of composite resin for the manufacturing of RBFDP increases the displacement of the set during the loading. However, it reduces the amount of stress concentration at the adhesive interface in comparison with the other materials.
Collapse
Affiliation(s)
- João Paulo M Tribst
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Brazil; Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan #3004, 1081, LA Amsterdam, Noord-Holland, the Netherlands.
| | - Amanda M O Dal Piva
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Brazil; Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan #3004, 1081, LA Amsterdam, Noord-Holland, the Netherlands.
| | - Renata M de Melo
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Engenheiro Francisco José Longo Avenue, 777, 12245-000, São José Dos Campos/SP, Brazil.
| | - Alexandre L S Borges
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Engenheiro Francisco José Longo Avenue, 777, 12245-000, São José Dos Campos/SP, Brazil.
| | - Marco Antonio Bottino
- Post-Graduate Program in Restorative Dentistry (Prosthodontic), Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp/SJC), Engenheiro Francisco José Longo Avenue, 777, 12245-000, São José Dos Campos/SP, Brazil.
| | - Mutlu Özcan
- University of Zürich, Dental Materials Unit, Center for Dental and Oral Medicine, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science, Rämistrasse 71, 8006, Zurich, Switzerland.
| |
Collapse
|