1
|
Yang K, Sun J, Zhao Y, Yang X, Sun L, Wu L, Liu Y, Shi S. Low-dose and low-contrast computed tomography pulmonary angiography in pediatric with pulmonary embolism: a prospective study. BMC Med Imaging 2025; 25:123. [PMID: 40241024 PMCID: PMC12004619 DOI: 10.1186/s12880-025-01665-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2025] [Accepted: 04/07/2025] [Indexed: 04/18/2025] Open
Abstract
OBJECTIVE We evaluated the feasibility of reducing contrast agent and radiation dose in pediatric computed tomography pulmonary angiography (CTPA) while ensuring image quality. MATERIALS AND METHODS In this prospective study, two readers assessed the computed tomography (CT) image quality (using a 5-point scale (1: undiagnosable and 5: excellent) and objective evaluation criteria (measuring CT and noise values of the left atrium and pulmonary trunk) of 116 patients who underwent pulmonary artery computed tomography angiography (CTA) from January 2023 to April 2024. independent sample t-test and Chi-square test were used to analyze and evaluate group differences. RESULT Fifty-eight participants were enrolled in the study group (mean age, 6.86 years ± 2.74, 30 males) and fifty-eight participants were enrolled in the control group (mean age, 6.71 years ± 2.59, 22 males). The radiation dose was significantly decreased in the study group (study group, 3.01 ± 0.24 mGy, control group 3.77 ± 1.06 mGy, p < 0.001). Overall quality was higher in control group, but displaying ability of pulmonary artery trunk and branch was higher in study group (p < 0.001). CONCLUSION This study proved that a low-dose, low-contrast CTPA strategy could reduce radiation dosage by 50% and contrast agent by 20% while maintaining a satisfying image quality.
Collapse
Affiliation(s)
- Kaihua Yang
- Medical Imaging Department, Children's Hospital Affiliated to Zhengzhou University, Zhengzhou, Henan, 450018, China
| | - Jihang Sun
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China
| | - Yidi Zhao
- Medical Imaging Department, Children's Hospital Affiliated to Zhengzhou University, Zhengzhou, Henan, 450018, China
| | - Xin Yang
- Medical Imaging Department, Children's Hospital Affiliated to Zhengzhou University, Zhengzhou, Henan, 450018, China
| | - Lifang Sun
- Medical Imaging Department, Children's Hospital Affiliated to Zhengzhou University, Zhengzhou, Henan, 450018, China
| | - Ling Wu
- Medical Imaging Department, Children's Hospital Affiliated to Zhengzhou University, Zhengzhou, Henan, 450018, China
| | - Yue Liu
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China.
| | - Shengli Shi
- Medical Imaging Department, Children's Hospital Affiliated to Zhengzhou University, Zhengzhou, Henan, 450018, China.
| |
Collapse
|
2
|
Cheong D, Alloah Q, Fishbein JS, Rajagopal HG. Comparison and Agreement between Cardiovascular Computed Tomography-Derived Mid-Diastolic and End-Diastolic Ventricular Volume in Patients with Congenital Heart Disease. Pediatr Cardiol 2025; 46:844-852. [PMID: 38689021 DOI: 10.1007/s00246-024-03504-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 04/19/2024] [Indexed: 05/02/2024]
Abstract
Prospective electrocardiogram (ECG)-triggered cardiovascular computed tomography (CCT) is primarily utilized for anatomical information in congenital heart disease (CHD) and has not been utilized for calculation of the end-diastolic volume (EDV); however, the mid-diastolic volume (MDV) may be measured. The objective of this study was to evaluate the feasibility and agreement between ventricular EDV and MDV. 31 retrospectively ECG-gated CCT were analyzed for the study of the 450 consecutive CCT. CCT images were processed using syngo.via with automatic contouring followed by manual adjustment of the endocardial borders of the left ventricles (LV) and right ventricles (RV) at end-diastolic and mid-diastolic phase (measured at 70% of cardiac cycle). The correlation and agreements between EDV and MDV were demonstrated using Spearman rank coefficient and intraclass correlation coefficient (ICC), respectively. Mean age ± SD was 28.8 ± 12.5 years, 19 were male (61.3%) and tetralogy of Fallot (TOF) was the most common diagnosis (58.1%), 35% (11/31) patients with a pacemaker, ICD or other such contraindication for a CMRI, 23% (7/31) with claustrophobia, and 6.5% (2/31) with developmental delay with refusal for sedation did not have a previous CMRI. The mean ± SD indexed LV EDV and LV MDV were 91.1 ± 24.5 and 84.8 ± 22.3 ml/m2, respectively. The mean ± SD indexed RV EDV and RV MDV were 136.8 ± 41 and 130.2 ± 41.5 ml/m2, respectively. EDV and MDV had a strong positive correlation and good agreement (ICC 0.92 for LV and 0.95 for RV). This agreement was preserved in a subset of patients (21) with dilated RV (indexed RV EDV z-score > 2). Intra-observer reliability (0.97 and 0.98 for LV and RV MDV, respectively) and inter-observer reliability (0.96 and 0.90 for LV and RV MDV, respectively) were excellent. In a select group of patients with CHD, measuring MDV by CCT is feasible and these values have good agreements with EDV. This may be used to derive functional data from prospectively ECG-triggered CCT studies. Further large-scale analysis is needed to determine accuracy and clinical correlation.
Collapse
Affiliation(s)
- Daniel Cheong
- Pediatric Cardiology, Cohen Children's Medical Center, Northwell Health, 2000 Marcus Ave, Suite 300, New Hyde Park, NY, 11042-1069, USA.
| | - Qais Alloah
- Pediatric Cardiology, Cohen Children's Medical Center, Northwell Health, 2000 Marcus Ave, Suite 300, New Hyde Park, NY, 11042-1069, USA
| | - Joanna S Fishbein
- Biostatistics Unit, Office of Academic Affairs, Northwell Health, New Hyde Park, USA
| | - Hari G Rajagopal
- Pediatric Cardiology, Cohen Children's Medical Center, Northwell Health, 2000 Marcus Ave, Suite 300, New Hyde Park, NY, 11042-1069, USA
| |
Collapse
|
3
|
Clinical Question Influence on Radiation Dose of Cardiac CT Scan in Children. CHILDREN (BASEL, SWITZERLAND) 2022; 9:children9081172. [PMID: 36010062 PMCID: PMC9406619 DOI: 10.3390/children9081172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 07/25/2022] [Accepted: 08/04/2022] [Indexed: 11/16/2022]
Abstract
Background: To assess the impact of different clinical questions on radiation doses acquired during cardiac computed tomography in children. Methods: A total of 116 children who underwent cardiac CT on a third-generation dual-source CT scanner were included. The clinical questions were divided into three main categories: the extent of scanning in the z-axis, coronary artery assessment and cardiac function assessment. Radiation dose values represented as a dose-length product (DLP) in mGy*cm were recorded from the CT scanner protocols. Results: There were significantly higher doses in cases with cardiac function assessment (median DLP 348 versus 59 mGy*cm, p < 0.01) and in cases with coronary artery assessment (median DLP 133 versus 71 mGy*cm, p < 0.01). Conclusion: The most important factor was the assessment of cardiac function, where the median radiation dose was 4.3× higher in patients with a request for cardiac function assessment. We strongly recommend that clinical requests for cardiac CT should be carefully considered in the paediatric population.
Collapse
|
4
|
Hustings N, Bosmans H, Dymarkowski S. PURSUING OPTIMAL RADIATION DOSE IN PEDIATRIC CARDIAC CT: A REPORT FROM UNIVERSITY HOSPITAL LEUVEN. RADIATION PROTECTION DOSIMETRY 2022; 198:139-146. [PMID: 35137188 DOI: 10.1093/rpd/ncac007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 01/10/2022] [Accepted: 01/11/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND Computed tomography (CT) balances between high resolution and low radiation dose. Given the greater radiosensitivity of children, it is appropriate to use child-friendly CT-protocols that reduce radiation dose at acceptable image quality.This article states the radiation dose in pediatric cardiac CT-examinations at university hospital Leuven (Belgium) and compares with findings published by similar medical centers. The diagnostic accuracy was simultaneously compared, as it correlates with radiation dose. MATERIAL AND METHODS his retrospective observational study analyzed 58 CT-scans of 52 patients. The radiation dose was calculated in effective dose. The image quality was scored qualitatively with a 5-point scale. The diagnostic accuracy, a derivative representation of the image quality, was checked with findings from surgery or conventional angiography. RESULTS The mean effective dose in our study population was 1.3 ± 0.4 mSv. The qualitative image quality was on average 'good', elaborated with a score of 4.0 ± 0.2. The diagnostic accuracy was 92%. Comparative literature study provides a mean effective dose of 1.5 mSv and the reported diagnostic accuracy from other centers reaches ≥90%. CONCLUSIONS At our center pediatric cardiac CT-scans are obtained with good-to-excellent image quality and high diagnostic accuracy at low radiation doses. These results meet the radiation dose and diagnostic accuracy as published by comparable medical centers.
Collapse
Affiliation(s)
- Nico Hustings
- Radiology Resident in University Hospital of Leuven, University Hospital of Leuven, Herestraat 49, Leuven 3000, Belgium
| | - Hilde Bosmans
- Medical Physics and Quality Control in University Hospital of Leuven, University Hospital of Leuven, Herestraat 49, Leuven 3000, Belgium
| | - Steven Dymarkowski
- Radiologist in University Hospital of Leuven, University Hospital of Leuven, Herestraat 49, Leuven 3000, Belgium
| |
Collapse
|
5
|
Sun J, Li H, Li J, Cao Y, Zhou Z, Li M, Peng Y. Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study. Quant Imaging Med Surg 2021; 11:4162-4171. [PMID: 34476196 DOI: 10.21037/qims-20-1159] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 04/22/2021] [Indexed: 01/22/2023]
Abstract
Background Iterative reconstruction algorithms are often used to reduce image noise in low-dose coronary computed tomography angiography (CCTA) but encounter limitations. The newly introduced deep learning image reconstruction (DLIR) algorithm may provide new opportunities. We assessed the image quality and diagnostic performance of DLIR in low radiation dose and contrast medium dose CCTA of pediatric patients with 70 kVp and a shortened injection protocol. Methods This was a prospective study. A total of 27 consecutive arrhythmic pediatric patients were enrolled in the study group and underwent CCTA using a prospective ECG-triggered single-beat protocol: tube voltage 70 kVp, automatic tube current modulation for a noise index (NI) of 22, and contrast dose of 0.4-0.6 mL/kg. Images were reconstructed with DLIR. They were compared with 27 matched patients in the control group scanned with 80 kVp, a lower NI setting (NI =19), and a higher contrast dose (0.8-1.2 mL/kg). The images in the control group were reconstructed using the adaptive statistical iterative reconstruction (ASIR-V) algorithm. The image contrast, image quality, and diagnostic confidence were assessed by 2 experienced radiologists using a 5-point scale (1: nondiagnostic and 5: excellent). The CT value and standard deviation of the aorta and perivascular tissue were measured, and the contrast-to-noise ratio (CNR) for the aorta was calculated. The contrast medium and radiation doses were compared. Results The study and control groups had similar image contrast scores (4.75±0.57 vs. 4.78±0.42), image quality scores (3.67±0.47 vs. 3.44±0.51), and diagnostic confidence (4.74±0.44 vs. 4.74±0.45) (all P>0.05). There was an adequate enhancement in the aorta (614.74±127.73 vs. 705.89±111.20 HU) and similar CNR (20.34±4.64 vs. 20.99±4.14) in both groups. The image noise of the study group was lower in the aorta (30.61±3.88 vs. 34.77±3.49) and similar in perivascular tissue (27.66±6.24 vs. 27.55±3.33) compared with the control group. The study group reduced the total contrast medium dose by 53% to 15.07±3.68 mL and radiation dose by 36% to 0.57±0.31 mSv. Conclusions The DLIR algorithm in CCTA for children using 70 kVp tube voltage with a shortened contrast medium injection protocol maintains image quality and diagnostic confidence while significantly reducing contrast medium dose and radiation dose compared with the use of the conventional CCTA protocol.
Collapse
Affiliation(s)
- Jihang Sun
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Haoyan Li
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | | | - Yongli Cao
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Zuofu Zhou
- Department of Radiology, Fujian Provincial Maternity and Children's Hospital, Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Michelle Li
- Department of Human Biology, Stanford University, CA, USA
| | - Yun Peng
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| |
Collapse
|
6
|
New-generation multidetector computed tomography technology for the management of congenital heart disease in children: Now we can! Rev Port Cardiol 2021; 40:591-593. [PMID: 34392903 DOI: 10.1016/j.repce.2021.07.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
7
|
António M. New-generation multidetector computed tomography technology for the management of congenital heart disease in children: Now we can! Rev Port Cardiol 2021. [DOI: 10.1016/j.repc.2021.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
8
|
Öztürk E, Tanıdır İC, Kamalı H, Ayyıldız P, Topel C, Selen Onan İ, Türkvatan A, Haydin S, Güzeltaş A. Comparison of echocardiography and 320-row multidetector computed tomography for the diagnosis of congenital heart disease in children. Rev Port Cardiol 2021; 40:583-590. [PMID: 34392902 DOI: 10.1016/j.repce.2020.12.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 12/11/2020] [Indexed: 10/20/2022] Open
Abstract
INTRODUCTION Echocardiography (echo) is the primary non-invasive imaging modality for the assessment of congenital heart disease (CHD). Computed tomography angiography (CTA) also has potential to examine the anatomy of complex heart anomalies as well as extracardiac involvement. OBJECTIVES The aim of this study is to determine the impact of new CTA technology in the diagnosis of CHD and to compare echo and CTA in terms of diagnostic accuracy. METHODS Forty-five patients who underwent preoperative echo and CTA assessment in the intensive care unit were included in this study. The results were assessed for three main types of CHD (cardiac malformations, cardiac-major vessel connections and major vessels). The main groups were also divided into subgroups according to surgical features in order to assess them more objectively. Imaging methods were compared for diagnostic accuracy, sensitivity and specificity, while surgical findings were accepted as the gold standard. RESULTS Patients' median age and weight were two months (three days-eight years) and 12 kg (2.5-60 kg), respectively. In 45 operated cases, 205 subgroup malformations were assessed. Diagnostic accuracy was significantly greater in echo (echo vs. CTA: 98.4% and 96.2% [chi-square=6.4, p=0.011]). During surgery, 84 cardiac malformations (echo vs. CTA: 97.4% and 95.1% [chi-square=4.9, p=0.03]), 47 cardiac-major vessel connections (echo vs. CTA: 98.3% and 95.4% [chi-square=7.5, p=0.03]), and 74 major vessel malformations (echo vs. CTA: 96% and 98% [chi-square=1.8, p=0.48]) were confirmed. CONCLUSION Echocardiography and CTA are imaging methods with high diagnostic accuracy in children with CHD. The use of echocardiography together with CTA, especially for the visualization of extracardiac anatomy, provides additional information for clinicians.
Collapse
Affiliation(s)
- Erkut Öztürk
- Department of Pediatric Cardiology, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey.
| | - İbrahim Cansaran Tanıdır
- Department of Pediatric Cardiology, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey
| | - Hacer Kamalı
- Department of Pediatric Cardiology, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey
| | - Pelin Ayyıldız
- Department of Pediatric Cardiology, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey
| | - Cagdas Topel
- Department of Radyology, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey
| | - İsmihan Selen Onan
- Department of Cardiovascular Surgery, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey
| | - Aysel Türkvatan
- Department of Radyology, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey
| | - Sertaç Haydin
- Department of Cardiovascular Surgery, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey
| | - Alper Güzeltaş
- Department of Pediatric Cardiology, Istanbul Saglik Bilimleri University Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey
| |
Collapse
|
9
|
Comparison of echocardiography and 320-row multidetector computed tomography for the diagnosis of congenital heart disease in children. Rev Port Cardiol 2021. [PMID: 34120823 DOI: 10.1016/j.repc.2020.12.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
INTRODUCTION Echocardiography (echo) is the primary non-invasive imaging modality for the assessment of congenital heart disease (CHD). Computed tomography angiography (CTA) also has potential to examine the anatomy of complex heart anomalies as well as extracardiac involvement. OBJECTIVES The aim of this study is to determine the impact of new CTA technology in the diagnosis of CHD and to compare echo and CTA in terms of diagnostic accuracy. METHODS Forty-five patients who underwent preoperative echo and CTA assessment in the intensive care unit were included in this study. The results were assessed for three main types of CHD (cardiac malformations, cardiac-major vessel connections and major vessels). The main groups were also divided into subgroups according to surgical features in order to assess them more objectively. Imaging methods were compared for diagnostic accuracy, sensitivity and specificity, while surgical findings were accepted as the gold standard. RESULTS Patients' median age and weight were two months (three days-eight years) and 12 kg (2.5-60 kg), respectively. In 45 operated cases, 205 subgroup malformations were assessed. Diagnostic accuracy was significantly greater in echo (echo vs. CTA: 98.4% and 96.2% [chi-square=6.4, p=0.011]). During surgery, 84 cardiac malformations (echo vs. CTA: 97.4% and 95.1% [chi-square=4.9, p=0.03]), 47 cardiac-major vessel connections (echo vs. CTA: 98.3% and 95.4% [chi-square=7.5, p=0.03]), and 74 major vessel malformations (echo vs. CTA: 96% and 98% [chi-square=1.8, p=0.48]) were confirmed. CONCLUSION Echocardiography and CTA are imaging methods with high diagnostic accuracy in children with CHD. The use of echocardiography together with CTA, especially for the visualization of extracardiac anatomy, provides additional information for clinicians.
Collapse
|
10
|
Khan MU, Aziz S, Javeria MC, Shahjehan A, Mushtaq Z, Iqtidar K. ECG Signal Analysis for Classification of Congenital Heart Defects. 2020 INTERNATIONAL CONFERENCE ON COMPUTING AND INFORMATION TECHNOLOGY (ICCIT-1441) 2020:1-5. [DOI: 10.1109/iccit-144147971.2020.9213825] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
11
|
Barrera CA, Otero HJ, White AM, Saul D, Biko DM. Image Quality of ECG-Triggered High-Pitch, Dual-Source Computed Tomography Angiography for Cardiovascular Assessment in Children. Curr Probl Diagn Radiol 2020; 49:23-28. [DOI: 10.1067/j.cpradiol.2018.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 10/19/2018] [Accepted: 10/23/2018] [Indexed: 11/22/2022]
|
12
|
Schicchi N, Fogante M, Esposto Pirani P, Agliata G, Basile MC, Oliva M, Agostini A, Giovagnoni A. Third-generation dual-source dual-energy CT in pediatric congenital heart disease patients: state-of-the-art. LA RADIOLOGIA MEDICA 2019; 124:1238-1252. [PMID: 31630332 DOI: 10.1007/s11547-019-01097-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 10/09/2019] [Indexed: 12/11/2022]
Abstract
Cardiovascular computer tomography (CT) in pediatric congenital heart disease (CHD) patients is often challenging. This might be due to limited patient cooperation, the high heart rate, the complexity and variety of diseases and the need for radiation dose minimization. The recent developments in CT technology with the introduction of the third-generation dual-source (DS) dual-energy (DE) CT scanners well suited to respond to these challenges. DSCT is characterized by high-pitch, long anatomic coverage and a more flexible electrocardiogram-synchronized scan. DE provides additional clinical information about vascular structures, myocardial and lung perfusion and allows artifacts reduction. These advances have increased clinical indications and modified CT protocol for pediatric CHD patients. In our hospital, DSCT with DE technology has rapidly become an important imaging technique for both pre- and postoperative management of pediatric patients with CHDs. The aim of this article is to describe the state-of-the-art in DSCT protocol with DE technology in pediatric CHD patients, providing some case examples of our experience over an 18-month period.
Collapse
Affiliation(s)
- Nicolò Schicchi
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Marco Fogante
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy.
| | - Paolo Esposto Pirani
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Giacomo Agliata
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Maria Chiara Basile
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Matteo Oliva
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Andrea Agostini
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Andrea Giovagnoni
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| |
Collapse
|
13
|
|
14
|
Li T, Zhao S, Liu J, Yang L, Huang Z, Li J, Luo C, Li X. Feasibility of high-pitch spiral dual-source CT angiography in children with complex congenital heart disease compared to retrospective-gated spiral acquisition. Clin Radiol 2017; 72:864-870. [DOI: 10.1016/j.crad.2017.05.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 04/01/2017] [Accepted: 05/08/2017] [Indexed: 10/19/2022]
|
15
|
Hedgire SS, Baliyan V, Ghoshhajra BB, Kalra MK. Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments. J Med Imaging (Bellingham) 2017; 4:031211. [PMID: 28894760 DOI: 10.1117/1.jmi.4.3.031211] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Accepted: 07/28/2017] [Indexed: 12/24/2022] Open
Abstract
Cardiac imagers worldwide are bracing for increased utilization of cardiac computed tomography (CT) in clinical practice. This expanding opportunity brings along a responsibility to produce diagnostic quality images with optimized radiation dose. The following review aims to address the dose reduction strategies in cardiac CT in light of recent scientific evidence and technical developments.
Collapse
Affiliation(s)
- Sandeep S Hedgire
- Massachusetts General Hospital, Department of Imaging, Division of Cardiovascular Imaging, Boston, Massachusetts, United States
| | - Vinit Baliyan
- Massachusetts General Hospital, Department of Imaging, Division of Cardiovascular Imaging, Boston, Massachusetts, United States
| | - Brian B Ghoshhajra
- Massachusetts General Hospital, Department of Imaging, Division of Cardiovascular Imaging, Boston, Massachusetts, United States
| | - Mannudeep K Kalra
- Massachusetts General Hospital, Department of Imaging, Division of Cardiovascular Imaging, Boston, Massachusetts, United States
| |
Collapse
|
16
|
Prospective ECG-triggering cardiac CT for infants with complex congenital heart disease using low-dose contrast medium, low tube voltage, and adaptive statistical iterative reconstruction. Clin Radiol 2017; 72:502-507. [PMID: 28267987 DOI: 10.1016/j.crad.2017.01.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 01/04/2017] [Accepted: 01/30/2017] [Indexed: 11/21/2022]
Abstract
AIM To demonstrate the clinical value of prospective electrocardiography (ECG)-triggered cardiac computed tomography (CT) with low concentration contrast medium, low tube voltage, and adaptive statistic iterative reconstruction (ASIR) to reduce both radiation and contrast dose in examining infants with complex congenital heart disease (CHD). MATERIALS AND METHODS Forty-four consecutive infants (19 male, 25 female, age: 8.06±4.33 months, weight: 7.31±1.36 kg) with complex CHD underwent prospective ECG-triggered low-dose cardiac CT using 80 kVp and 120 mA. The contrast agent was iodixanol (270 mg iodine/ml, Visipaque, GE Healthcare, Co. Cork, Ireland). Cardiac CT images were reconstructed with 70% ASIR. The quantitative CT image quality was assessed by image noise in adipose tissue and contrast-to-noise ratio (CNR) in the aorta. The qualitative image analysis was performed on a five-point grading scale by two independent reviewers and interobserver variability was calculated. The results of 32 CT examinations were also compared with the available surgical results for diagnostic accuracy evaluation. RESULTS The effective dose was 0.55±0.10 mSv for the patient population. The iodine load was 3.95±0.73 g iodine. Image noise in adipose tissue was 16.24±1.42 HU and CNR in aorta was 21.90±7.10. All images were acceptable for diagnosis with an average score of 4.52±0.38 and good agreement between reviewers (kappa=0.75). Compared to the surgery results in 32 cases, CT was 97% and 88% accurate diagnosing extracardiac and intracardiac defects, respectively. CONCLUSION Prospective ECG-triggered cardiac CT using 80 kVp, low-concentration iodinated contrast agent (270 mg iodine/ml) and 70% ASIR reconstruction provides excellent image quality and accurate diagnosis for complex congenital heart disease in infants with reduced contrast medium dose and low radiation dose.
Collapse
|
17
|
|
18
|
Czeyda-Pommersheim F. A Breath of Fresh Air: Can High-pitch CT Make Free-breathing PE Scanning Possible? Acad Radiol 2016; 23:1333-1334. [PMID: 27742178 DOI: 10.1016/j.acra.2016.08.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Accepted: 08/31/2016] [Indexed: 11/28/2022]
|