1
|
Nellaiappan S, Vishnu N, Manoj D, Kanagaraj T, Selvaraj M, Assiri MA. Electrochemical flow injection analysis platforms for biomedical applications - Progress and prospects. Anal Biochem 2025; 700:115795. [PMID: 39894143 DOI: 10.1016/j.ab.2025.115795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2024] [Revised: 01/27/2025] [Accepted: 01/28/2025] [Indexed: 02/04/2025]
Abstract
Flow injection analysis coupled with electrochemical detection (FIA-ECD) techniques has to be a key technological development for wide variety of applications in various domains such as synthetic analytical chemistry, materials science, biomedical and point-of-care devices. FIA-ECD techniques have to be unique due to decreasing the time of analysis, sample pre-treatment, reactions and separation-free detection for multi-analytes. In biomedical domain, various electrochemical sensors were decorated with bioactive molecules, i.e., DNA, antibodies, enzymes along with biocompatible polymers for the detection of biologically important chemicals and analytes. The flexibility and practical applicability of these sensors may serve as a new pattern for clinical and biomedical analytical instrumentations. This review covers the highlights and overview of the most successful and promising electrochemical sensors, biosensors and immunosensors integrated with the flow injection analysis platforms, fabrication and analytical parameters, pros and cons of these sensor technologies, challenges and future opportunities in point-of-care clinical analysis.
Collapse
Affiliation(s)
- Subramanian Nellaiappan
- Centre of Excellence for Energy Research, Centre for Nanoscience and Nanotechnology, Sathyabama Institute of Science and Technology, Chennai, 600119, Tamil Nadu, India.
| | - Nandimalla Vishnu
- Department of Chemistry, GITAM School of Science, GITAM Deemed to Be University, Hyderabad, Telangana, 502329, India
| | - Devaraj Manoj
- Department of Chemistry, Karpagam Academy of Higher Education, Coimbatore, 641 021, India; Centre for Material Chemistry, Karpagam Academy of Higher Education, Coimbatore, 641 021, India
| | - Thamaraiselvi Kanagaraj
- Department of Biomaterials, Saveetha Dental College and Hospital, SIMATS, Saveetha University, Chennai, 600 077, India; School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongbuk, 38541, Republic of Korea
| | - Manickam Selvaraj
- Department of Chemistry, Faculty of Science, King Khalid University, Abha, 61413, Saudi Arabia; Research Centre for Advanced Materials Science (RCAMS), King Khalid University, PO Box 9004, Abha, 61413, Saudi Arabia
| | - Mohammed A Assiri
- Department of Chemistry, Faculty of Science, King Khalid University, Abha, 61413, Saudi Arabia; Research Centre for Advanced Materials Science (RCAMS), King Khalid University, PO Box 9004, Abha, 61413, Saudi Arabia
| |
Collapse
|
2
|
Pan S, Yin L, Liu J, Tong J, Wang Z, Zhao J, Liu X, Chen Y, Miao J, Zhou Y, Zeng S, Xu T. Metabolomics-driven approaches for identifying therapeutic targets in drug discovery. MedComm (Beijing) 2024; 5:e792. [PMID: 39534557 PMCID: PMC11555024 DOI: 10.1002/mco2.792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2024] [Revised: 09/29/2024] [Accepted: 09/30/2024] [Indexed: 11/16/2024] Open
Abstract
Identification of therapeutic targets can directly elucidate the mechanism and effect of drug therapy, which is a central step in drug development. The disconnect between protein targets and phenotypes under complex mechanisms hampers comprehensive target understanding. Metabolomics, as a systems biology tool that captures phenotypic changes induced by exogenous compounds, has emerged as a valuable approach for target identification. A comprehensive overview was provided in this review to illustrate the principles and advantages of metabolomics, delving into the application of metabolomics in target identification. This review outlines various metabolomics-based methods, such as dose-response metabolomics, stable isotope-resolved metabolomics, and multiomics, which identify key enzymes and metabolic pathways affected by exogenous substances through dose-dependent metabolite-drug interactions. Emerging techniques, including single-cell metabolomics, artificial intelligence, and mass spectrometry imaging, are also explored for their potential to enhance target discovery. The review emphasizes metabolomics' critical role in advancing our understanding of disease mechanisms and accelerating targeted drug development, while acknowledging current challenges in the field.
Collapse
Affiliation(s)
- Shanshan Pan
- Research Center for Clinical PharmacyCollege of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
- College of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
| | - Luan Yin
- College of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
| | - Jie Liu
- College of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
| | - Jie Tong
- Department of Radiology and Biomedical ImagingPET CenterYale School of MedicineNew HavenConnecticutUSA
| | - Zichuan Wang
- Research Center for Clinical PharmacyCollege of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
- College of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
| | - Jiahui Zhao
- School of Basic Medical SciencesZhejiang Chinese Medical UniversityHangzhouChina
| | - Xuesong Liu
- College of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
- Cangnan County Qiushi Innovation Research Institute of Traditional Chinese MedicineWenzhouZhejiangChina
| | - Yong Chen
- College of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
- Cangnan County Qiushi Innovation Research Institute of Traditional Chinese MedicineWenzhouZhejiangChina
| | - Jing Miao
- Research Center for Clinical PharmacyCollege of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
| | - Yuan Zhou
- School of Basic Medical SciencesZhejiang Chinese Medical UniversityHangzhouChina
| | - Su Zeng
- Research Center for Clinical PharmacyCollege of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
- College of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
| | - Tengfei Xu
- Research Center for Clinical PharmacyCollege of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
- College of Pharmaceutical SciencesZhejiang UniversityHangzhouZhejiangChina
| |
Collapse
|
3
|
Jiménez-Morales WA, Cañizares-Macias MDP. Fast FRAP-SIA method to determine antioxidant capacity. Talanta 2024; 273:125813. [PMID: 38461642 DOI: 10.1016/j.talanta.2024.125813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 02/14/2024] [Accepted: 02/17/2024] [Indexed: 03/12/2024]
Abstract
One of the most used methods to measure antioxidant capacity in food is the ferric reducing antioxidant power (FRAP) test, which is simple, sensitive, and economical, nevertheless has long analysis times, causing measurement errors due to the instability of the FRAP reagent due to its precipitation sequential injection analysis (SIA) is a flow technique that can correct these disadvantages because it is more quickly. So, a novel FRAP-SIA method was developed to evaluate the antioxidant capacity. The system was optimized using a central composite design for hydrodynamic and chemical factors, resulting in a flow rate of 35 μL s-1, and aspirate volumes of 33 μL-38 μL-33 μL for the sequence (FRAP-Antioxidant-FRAP). FRAP reagent was prepared with an HCl solution at 0.005 mol L-1, improving its stability 24 times, concerning when it is in acetate buffer at pH 3.6. The method showed excellent accuracy (RSD <3%) with a LOD of 1.0 μmol L-1 of Trolox for a linear range of 5-120 μmol L-1. The reaction time was diminished by 96% concerning the FRAP-microplate assay (from 30 min to 1.2 min). The method was applied in beverages and extracts, obtaining recovery values ranging from 91.24 to 114.22%.
Collapse
Affiliation(s)
- Willmann Antonio Jiménez-Morales
- Departamento de Química Analítica, Facultad de Química, Universidad Nacional Autónoma de México, Av. Universidad 3000, Ciudad de México, C.P. 04510, Mexico
| | - María Del Pilar Cañizares-Macias
- Departamento de Química Analítica, Facultad de Química, Universidad Nacional Autónoma de México, Av. Universidad 3000, Ciudad de México, C.P. 04510, Mexico.
| |
Collapse
|
4
|
Abdullah NS, Hassan MA, Hassan RO. A Novel Flow Injection Method with Chemiluminescence Detection for the Determination of Carmoisine in Gelatin Desserts. J Fluoresc 2024:10.1007/s10895-024-03777-8. [PMID: 38780834 DOI: 10.1007/s10895-024-03777-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Accepted: 05/16/2024] [Indexed: 05/25/2024]
Abstract
Carmoisine dye, a red azo food colorant commonly utilized to impart a red color to synthetic food products, is the subject of this study. Here, we present a novel reversed flow injection analysis with a chemiluminescence detection (FIA-CL) method employing a newly developed homemade flow cell to determine carmoisine dye. This developed method is based on the inhibition effect of the dye on the chemiluminescence light (CL) emission generated from a luminal-hypochlorite system, whereby the reduction in CL intensity correlates directly with the concentration of carmoisine dye. Investigations into various analytical parameters were conducted to enhance method efficiency and applicability. A linear calibration graph of 4.0 to 100.0 µg mL-1 was established (R² = 0.9993), with a detection limit of LOD = 2.93 µg mL-1. Subsequent application of the proposed method to analyze gelatine dessert samples yielded results in reasonable agreement with those obtained using the reported HPLC method, as evidenced by student t-test and F-test analyses.
Collapse
Affiliation(s)
- Narmin S Abdullah
- Chemistry Department- Science College, Salahaddin University-Erbil, Erbil, Kurdistan Region, Iraq
| | - Media A Hassan
- Chemistry Department- Science College, Salahaddin University-Erbil, Erbil, Kurdistan Region, Iraq
| | - Rebwar O Hassan
- Chemistry Department- Science College, Salahaddin University-Erbil, Erbil, Kurdistan Region, Iraq.
- Department of Radiological Imaging Technology, College of Health Technology Cihan University-Erbil, Erbil, Kurdistan Region, Iraq.
| |
Collapse
|
5
|
Traipop S, Jesadabundit W, Khamcharoen W, Pholsiri T, Naorungroj S, Jampasa S, Chailapakul O. Nanomaterial-based Electrochemical Sensors for Multiplex Medicinal Applications. Curr Top Med Chem 2024; 24:986-1009. [PMID: 38584544 DOI: 10.2174/0115680266304711240327072348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 03/07/2024] [Accepted: 03/15/2024] [Indexed: 04/09/2024]
Abstract
This review explores the advancements in nanomaterial-based electrochemical sensors for the multiplex detection of medicinal compounds. The growing demand for efficient and selective detection methods in the pharmaceutical field has prompted significant research into the development of electrochemical sensors employing nanomaterials. These materials, defined as functional materials with at least one dimension between 1 and 100 nanometers, encompass metal nanoparticles, polymers, carbon-based nanocomposites, and nano-bioprobes. These sensors are characterized by their enhanced sensitivity and selectivity, playing a crucial role in simultaneous detection and offering a comprehensive analysis of multiple medicinal complexes within a single sample. The review comprehensively examines the design, fabrication, and application of nanomaterial- based electrochemical sensors, focusing on their ability to achieve multiplex detection of various medicinal substances. Insights into the strategies and nanomaterials employed for enhancing sensor performance are discussed. Additionally, the review explores the challenges and future perspectives of this evolving field, highlighting the potential impact of nanomaterial-based electrochemical sensors on the advancement of medicinal detection technologies.
Collapse
Affiliation(s)
- Surinya Traipop
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Whitchuta Jesadabundit
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Wisarut Khamcharoen
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
- Center of Excellence on Petrochemical and Materials Technology (PETROMAT), Thailand
| | - Tavechai Pholsiri
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Sarida Naorungroj
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Sakda Jampasa
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| |
Collapse
|
6
|
Xue Y, Hassan Q, Noroozifar M, Sullan RMA, Kerman K. Microfluidic flow injection analysis system for the electrochemical detection of dopamine using diazonium-grafted copper nanoparticles on multi-walled carbon nanotube-modified surfaces. Talanta 2024; 266:125030. [PMID: 37582331 DOI: 10.1016/j.talanta.2023.125030] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 06/27/2023] [Accepted: 08/02/2023] [Indexed: 08/17/2023]
Abstract
In this proof-of-concept study, a microfluidic flow injection analysis (FIA) system was developed using multi-walled carbon nanotube-modified screen-printed carbon electrodes (CNTSPEs) that were modified with copper nanoparticles (CuNPs) following the electrodeposition of the diazonium salt of 4-aminothiophenol to form 4-thiophenol-conjugated CuNPs (CuNPs-CNTSPE). Transmission electron microscopy (TEM), atomic force microscopy (AFM), and scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDS) were used to characterize the size of CuNPs, morphology and elemental analysis of CuNPs-CNTSPE, respectively. Using electrochemical impedance spectroscopy (EIS), the charge-transfer resistance (Rct) of CuNPs-CNTSPE was found to be 20-fold lower than that of CNTSPE. The CuNPs-CNTSPE displayed an oxidation peak for dopamine at -0.08 V which is ∼80 mV lower than the one detected using CNTSPE. The modified electrode was used in microfluidic flow injection analysis and offline systems for sensitive detection of dopamine (DA). The pH, flow rate, loop volume, concentration, and type of surfactant were all optimized for on-chip detection. Under the optimal conditions, using phosphate electrolyte solution (pH 6) containing 0.05% (w/v) Tween 20® as the carrier at a flow rate of 0.6 mL min-1 and a loop volume of 50 μL, the calibration curve was linear from 1.5 to 500 nM with a limit of detection of 0.33 nM. This technique was used for the successful detection of DA in real samples with recovery ranging from 96.5% to 103.8%. The microfluidic FIA system described here has the potential to be used as an electrochemical point-of-care device for rapid DA detection with high sensitivity and reproducibility.
Collapse
Affiliation(s)
- Yilei Xue
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
| | - Qusai Hassan
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
| | - Meissam Noroozifar
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada
| | - Ruby May A Sullan
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
| | - Kagan Kerman
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
| |
Collapse
|
7
|
Ayaz S, Karakaya S, Emir G, Uşaklıgil N, Giray Dilgin D, Dilgin Y. Flow-Injection Amperometric Determination of Glucose Using Nickel Oxide-Cobalt (II,III) Oxide and Nickel Oxide-Copper Nanoparticle Modified Pencil Graphite Electrodes. ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2043890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Selen Ayaz
- Department of Chemistry, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Serkan Karakaya
- Department of Chemistry, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Gamze Emir
- Department of Chemistry, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Nihan Uşaklıgil
- Department of Biochemistry, Medical Park Hospital Çanakkale, Çanakkale, Turkey
| | - Didem Giray Dilgin
- Department of Mathematics and Science Education, Faculty of Education, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Yusuf Dilgin
- Department of Chemistry, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| |
Collapse
|
8
|
Jiménez-Morales WA, Cañizares-Macias MDP, Pedraza-Chaverri J. Fast ORAC-SIA method for antioxidant capacity determination in food samples. Food Chem 2022; 384:132524. [PMID: 35245749 DOI: 10.1016/j.foodchem.2022.132524] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 02/17/2022] [Accepted: 02/18/2022] [Indexed: 11/04/2022]
Abstract
A novel fluorescent ORAC-SIA method to determine antioxidant capacity in several food samples using fluorescein as the probe was developed. The optimization of the method was through a multivariable design, decreasing the analysis time to 5 min and the AAPH concentration to 67% compared with 90 min in the standard 96-well microplate method. The aspiration order was AAPH-sample/standard-fluorescein injected into a stream of a water-based carrier. The calculation of the antioxidant capacity was done from the fluoresceine peak heigh, so neither delay time nor area measurement was necessary. The proposed method showed excellent precision (RDS < 3%) with a LOD of 3.13 µmol L-1 and recoveries from 90% to 107%. The results from the ORAC-SIA method did not show a significant difference from the microplate method.
Collapse
Affiliation(s)
- Willmann Antonio Jiménez-Morales
- Departamento de Química Analítica, Facultad de Química, Universidad Nacional Autónoma de México, Av. Universidad 3000, Ciudad de México C.P. 04510, Mexico
| | - María Del Pilar Cañizares-Macias
- Departamento de Química Analítica, Facultad de Química, Universidad Nacional Autónoma de México, Av. Universidad 3000, Ciudad de México C.P. 04510, Mexico.
| | - José Pedraza-Chaverri
- Departamento de Biología, Facultad de Química, Universidad Nacional Autónoma de México, Av. Universidad 3000, Ciudad de México C.P. 04510, Mexico
| |
Collapse
|
9
|
Medyantseva E, Gazizullina E, Brusnitsyn D, Ziganshin M, Mustafina A, Elistratova J, Brylev K, Budnikov H. Reduced Graphene Oxide, Nanodiamonds, and Hexarhenium Chalcogenide Clusters Incorporated into Amperometric Immunosensors for the Determination of Desipramine. ANAL LETT 2022. [DOI: 10.1080/00032719.2021.2025384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- E.P. Medyantseva
- A.M. Butlerov Institute of Chemistry, Kazan (Volga region) Federal University, Kazan, Russia
| | - E.R. Gazizullina
- A.M. Butlerov Institute of Chemistry, Kazan (Volga region) Federal University, Kazan, Russia
| | - D.V. Brusnitsyn
- A.M. Butlerov Institute of Chemistry, Kazan (Volga region) Federal University, Kazan, Russia
| | - M.A. Ziganshin
- A.M. Butlerov Institute of Chemistry, Kazan (Volga region) Federal University, Kazan, Russia
| | - A.R. Mustafina
- Arbuzov Institute of Organic and Physical Chemistry, FRC Kazan Scientific Center of RAS, Kazan, Russia
| | - J.G. Elistratova
- Arbuzov Institute of Organic and Physical Chemistry, FRC Kazan Scientific Center of RAS, Kazan, Russia
| | - K.A. Brylev
- Nikolaev Institute of Inorganic Chemistry, Novosibirsk, Russia
| | - H.C. Budnikov
- A.M. Butlerov Institute of Chemistry, Kazan (Volga region) Federal University, Kazan, Russia
| |
Collapse
|
10
|
Arnaboldi S, Salinas G, Bonetti G, Cirilli R, Benincori T, Kuhn A. Bipolar Electrochemical Measurement of Enantiomeric Excess with Inherently Chiral Polymer Actuators. ACS MEASUREMENT SCIENCE AU 2021; 1:110-116. [PMID: 34939074 PMCID: PMC8679086 DOI: 10.1021/acsmeasuresciau.1c00011] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Indexed: 05/11/2023]
Abstract
Straightforward enantioselective analytical methods are very important for drug safety, considering that in certain cases one of the two enantiomers of a chiral molecule might be harmful for humans. In this work, we propose a simple system for the direct and easy read-out of the enantiomeric excess of 3,4-dihydroxyphenylalanine (DOPA) as a model analyte. A conducting oligomer, i.e. oligo-(3,3'-dibenzothiophene), bearing inherently chiral features, is electrogenerated on a polypyrrole film. The resulting freestanding hybrid material is used as a wireless enantioselective actuator in a bipolar electrochemical cell. Combining in a single setup two individual actuators with opposite chiral features allows a direct visual read-out of enantiomeric excess, as the bending amplitude of each of the two actuators is directly correlated with the concentration of the corresponding stereoisomer of the analyte. Optimization of the experimental parameters results in efficient bending, giving access to the percentage values of the enantiomeric excess in mixtures containing different ratios of the antipodes, thus opening the way to potential applications for chiral in situ analysis.
Collapse
Affiliation(s)
- Serena Arnaboldi
- Université
de Bordeaux, CNRS UMR 5255, Bordeaux INP,
ENSCBP, 16 avenue Pey
Berland, 33607 Pessac, France
- Dipartimento
di Chimica, Universita degli Studi di Milano, Via Golgi 19, 20133 Milano, Italy
| | - Gerardo Salinas
- Université
de Bordeaux, CNRS UMR 5255, Bordeaux INP,
ENSCBP, 16 avenue Pey
Berland, 33607 Pessac, France
| | - Giorgia Bonetti
- Dipartimento
di Scienza e Alta Tecnologia, Universita
degli Studi dell’Insubria, Via Valleggio 11, 22100 Como, Italy
| | - Roberto Cirilli
- Centro
Nazionale per il Controllo e la Valutazione dei Farmaci, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Roma, Italy
| | - Tiziana Benincori
- Dipartimento
di Scienza e Alta Tecnologia, Universita
degli Studi dell’Insubria, Via Valleggio 11, 22100 Como, Italy
| | - Alexander Kuhn
- Université
de Bordeaux, CNRS UMR 5255, Bordeaux INP,
ENSCBP, 16 avenue Pey
Berland, 33607 Pessac, France
| |
Collapse
|
11
|
Medyantseva EP, Gazizullina ER, Brusnitsyn DV, Ziganshin MA, Elistratova YG, Mustafina AR, Brylev KA, Budnikov HC. Rhenium Nanoclusters as Modifiers of Immunosensors in the Determination of Tricyclic Antidepressants. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1134/s1061934821120078] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
12
|
Abstract
The multiple therapeutic potentials of tetracycline and its worldwide usage have encouraged researchers to develop various methods for its assay in various matrices and for different purposes. In this regard, different analytical techniques have been exploited. Among those techniques is flow injection (FI), which is an extended family of three generations and five versions. The current manuscript reviews the utilization of FI techniques for developing assay methods for tetracycline. The review covers more than forty methods, since the inception of FI techniques and up to date. The review highlights the advantages of the application of FI techniques for quantification of tetracycline in terms of reagent consumption, sample frequency, accuracy, and practitioner safety, besides instrumentation simplicity and cost-effectiveness. The review also addresses applications to several matrices ranging from simple matrices such as standard solutions and pharmaceutical formulations to complex matrices such as biological fluids and food. Prior to the review, a brief background on the principles and developments of FI techniques is illustrated.
Collapse
Affiliation(s)
- Mohammed D Y Oteef
- Department of Chemistry, College of Science, Jazan University, Jazan, Saudi Arabia
| | - Abubakr M Idris
- Department of Chemistry, College of Science, King Khalid University, Abha, Saudi Arabia.,Research Center for Advanced Materials Science (RCAMS), King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
13
|
Ivanova A, Gerasimova E, Gazizullina E. Study of Antioxidant Properties of Agents from the Perspective of Their Action Mechanisms. Molecules 2020; 25:E4251. [PMID: 32947948 PMCID: PMC7570667 DOI: 10.3390/molecules25184251] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 09/13/2020] [Accepted: 09/15/2020] [Indexed: 11/16/2022] Open
Abstract
The creation and analysis of a large variety of existing methods for the evaluation of integrated antioxidant properties are quite relevant in connection with a range of biological mechanisms of the antioxidants (AO) action. In this work, the existing methods are correlated with mechanisms of antioxidant action. It is shown that the results obtained by various methods are mainly incomparable. This can be connected with the implementation of various mechanisms of antioxidant action in methods. The analysis of the literature data presented in this review indicates the difficulty of creating a universal method and the feasibility of using integrated approaches based on the use of several methods that implement and combine various mechanisms of the chemical conversion of antioxidants. This review describes methods for studying the chelating ability of antioxidants, except for methods based on electron and hydrogen atom transfer reactions, which are currently not widely covered in modern literature. With the description of each mechanism, special attention is paid to electrochemical methods, as the interaction of active oxygen metabolites of radical and non-radical nature with antioxidants has an electron/proton/donor-acceptor nature, which corresponds to the nature of electrochemical methods and suggests that they can be used to study the interaction.
Collapse
Affiliation(s)
- Alla Ivanova
- Chemical Technological Institute, Ural Federal University Named after the First President of Russia B. N. Yeltsin, 620002 Ekaterinburg, Russia; (E.G.); (E.G.)
| | | | | |
Collapse
|
14
|
Integration of a photoelectrochemical cell in a flow system for quantification of 4-aminophenol with titanium dioxide. Electrochem commun 2020. [DOI: 10.1016/j.elecom.2020.106767] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
|
15
|
An ultrasensitive electroanalytical sensor based on MgO/SWCNTs- 1-Butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide paste electrode for the determination of ferulic acid in the presence sulfite in food samples. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104572] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
16
|
Yin J, Zhang W, Zhang Z, Jin H, Gao W, Jian J, Jin Q. Batch microfabrication and testing of a novel silicon-base miniaturized reference electrode with an ion-exchanging nanochannel array for nitrite determination. RSC Adv 2019; 9:19699-19706. [PMID: 35519384 PMCID: PMC9065324 DOI: 10.1039/c9ra01987a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Accepted: 06/07/2019] [Indexed: 12/03/2022] Open
Abstract
The reference electrode (RE) provides a stable potential for electrochemical detection; therefore, the RE plays an important role in environmental monitoring. In this paper, a novel batch of microfabricated silicon-base miniaturized Ag/AgCl RE was reported. A specially designed mini-tank for saturated KCl solution storage and a nanochannel array for ion-exchange were fabricated on a 4 inch (100) silicon wafer using a two-step KOH anisotropic etching process. An Ag/AgCl electrode was fabricated on a 4 inch Pyrex 7740 glass substrate. Finally, the finished silicon and glass substrates were anode bonded to form the entire system. By comparing with a conventional solid-state Ag/AgCl RE in electrochemical microsensors, a pre-packaged saturated KCl solution in the mini-tank provided a stable working environment for the Ag/AgCl electrode to ensure a constant reference potential. Compared with a routine glass-structured RE and by replacing the ion-exchange membrane with a nanochannel array, the miniaturized RE achieved a longer lifetime. The size of the finished miniaturized RE electrode was 11 mm × 14 mm. The reference potential variation was only 0.1 mV under continuous testing for 3000 s. The standard deviation in the reference potential was only 1.314 mV in different Na2SO4 buffer concentrations ranging from 3 mM to 30 mM. To verify the practicality of the novel silicon-base miniaturized RE, the fabricated RE was applied to measure the amount of nitrite in a water sample and achieved a better linearity of R2 = 0.998. This miniaturized RE showed better reference potential stability and consistency because of the batch fabrication technique. This novel strategy for the design and manufacture of the miniaturized RE shows a bright future in the wide use of electrochemical sensors in online monitoring of water pollutants. In this paper, a miniaturized Ag/AgCl reference electrode, which can be mass-produced by micro–nano manufacturing technology, was developed and demonstrated to have good stability and a long lifetime.![]()
Collapse
Affiliation(s)
- Jiawen Yin
- Faculty of Electrical Engineering and Computer Science
- Ningbo University
- Ningbo
- P. R. China
| | - Wei Zhang
- State Key Laboratory of Transducer Technology
- Center for Excellence in Superconducting Electronics
- Shanghai Institute of Microsystem and Information Technology
- Chinese Academy of Sciences
- Shanghai 200050
| | - Zan Zhang
- Faculty of Electrical Engineering and Computer Science
- Ningbo University
- Ningbo
- P. R. China
| | - Han Jin
- Faculty of Electrical Engineering and Computer Science
- Ningbo University
- Ningbo
- P. R. China
| | - Wanlei Gao
- Faculty of Electrical Engineering and Computer Science
- Ningbo University
- Ningbo
- P. R. China
| | - Jiawen Jian
- Faculty of Electrical Engineering and Computer Science
- Ningbo University
- Ningbo
- P. R. China
| | - Qinghui Jin
- Faculty of Electrical Engineering and Computer Science
- Ningbo University
- Ningbo
- P. R. China
- State Key Laboratory of Transducer Technology
| |
Collapse
|