1
|
Liu S, Jiang S, Yao Z, Liu M. Aflatoxin detection technologies: recent advances and future prospects. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:79627-79653. [PMID: 37322403 DOI: 10.1007/s11356-023-28110-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 06/01/2023] [Indexed: 06/17/2023]
Abstract
Aflatoxins have posed serious threat to food safety and human health. Therefore, it is important to detect aflatoxins in samples rapidly and accurately. In this review, various technologies to detect aflatoxins in food are discussed, including conventional ones such as thin-layer chromatography (TLC), high performance liquid chromatography (HPLC), enzyme linked immunosorbent assay (ELISA), colloidal gold immunochromatographic assay (GICA), radioimmunoassay (RIA), fluorescence spectroscopy (FS), as well as emerging ones (e.g., biosensors, molecular imprinting technology, surface plasmon resonance). Critical challenges of these technologies include high cost, complex processing procedures and long processing time, low stability, low repeatability, low accuracy, poor portability, and so on. Critical discussion is provided on the trade-off relationship between detection speed and detection accuracy, as well as the application scenario and sustainability of different technologies. Especially, the prospect of combining different technologies is discussed. Future research is necessary to develop more convenient, more accurate, faster, and cost-effective technologies to detect aflatoxins.
Collapse
Affiliation(s)
- Shenqi Liu
- School of Ecology and Environment, Beijing Technology and Business University, Beijing, 100048, China
- State Environmental Protection Key Laboratory of Food Chain Pollution Control, Beijing Technology and Business University, Beijing, 100048, China
| | - Shanxue Jiang
- School of Ecology and Environment, Beijing Technology and Business University, Beijing, 100048, China
- State Environmental Protection Key Laboratory of Food Chain Pollution Control, Beijing Technology and Business University, Beijing, 100048, China
| | - Zhiliang Yao
- School of Ecology and Environment, Beijing Technology and Business University, Beijing, 100048, China.
- State Environmental Protection Key Laboratory of Food Chain Pollution Control, Beijing Technology and Business University, Beijing, 100048, China.
| | - Minhua Liu
- School of Ecology and Environment, Beijing Technology and Business University, Beijing, 100048, China
- State Environmental Protection Key Laboratory of Food Chain Pollution Control, Beijing Technology and Business University, Beijing, 100048, China
| |
Collapse
|
2
|
Liu R, Zhang F, Sang Y, Liu M, Shi M, Wang X. Selection and Characterization of DNA Aptamers for Constructing Aptamer-AuNPs Colorimetric Method for Detection of AFM1. Foods 2022; 11:1802. [PMID: 35742000 PMCID: PMC9222373 DOI: 10.3390/foods11121802] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 06/11/2022] [Accepted: 06/17/2022] [Indexed: 12/03/2022] Open
Abstract
Aflatoxin M1 (AFM1), one of the most toxic mycotoxins, is a feed and food contaminant of global concern. To isolate the ssDNA aptamer of AFM1, synthesized magnetic graphene oxide nanomaterials, 12 rounds of subtractive systematic evolution of ligands by exponential enrichment (SELEX) selection were carried out. As a result, 24 candidate aptamers were selected, and their sequence similarity exceeded 97%. Their binding affinity and specificity were further examined by fluorescence and biofilm interferometry (BLI) methods. One aptamer (Apt-5) against AFM1 with a high affinity and specificity was isolated and demonstrated to be the optimal aptamer, whose dissociation constant reached the nanomolar level, Kd = 8.12 ± 1.51 nM. Additionally, molecular docking studies were used to predict the possible binding sites and mechanisms of the two. Based on Apt-5, an unlabeled aptamer-AuNPs colorimetric method was established to detect AFM1 in milk with a linear range of 0.078-10 ng/mL, and the actual detection limit was 0.078 ng/mL. These results demonstrated that this detection technique could be useful for the quantitative determination of AFM1 in milk and dairy products.
Collapse
Affiliation(s)
| | | | | | | | | | - Xianghong Wang
- College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China; (R.L.); (F.Z.); (Y.S.); (M.L.); (M.S.)
| |
Collapse
|
3
|
Qiao Q, Guo X, Wen F, Chen L, Xu Q, Zheng N, Cheng J, Xue X, Wang J. Aptamer-Based Fluorescence Quenching Approach for Detection of Aflatoxin M 1 in Milk. Front Chem 2021; 9:653869. [PMID: 33842437 PMCID: PMC8024576 DOI: 10.3389/fchem.2021.653869] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 02/18/2021] [Indexed: 11/13/2022] Open
Abstract
Aflatoxin M1 (AFM1), one of the most toxic mycotoxins, is a feed and food contaminant of global concern. In this study, we developed a fast and simple method for detection of AFM1 based on a structure-switching signaling aptamer. This aptasensor is based on the change in fluorescence signal due to formation of an AFM1/aptamer complex. To generate the aptasensor, the specific aptamer was modified with FAM (carboxyfluorescein), and their complementary DNAs (cDNA) were modified with a carboxytetramethylrhodamine (TAMRA) quenching group. In the absence of AFM1, the aptamers were hybridized with cDNA, resulting in quenching of the aptamer fluorescence due to the proximity of the aptamer's fluorophore to the quenching group on the cDNA. On the other hand, in the presence of AFM1, a structural switch in the aptamer was induced by formation of an AFM1/aptamer complex. Changes in the structure of the aptamer led to the release of the cDNA, causing the generation of a fluorescence signal. Thus, AFM1 concentrations could be quantitatively monitored based on the changes in fluorescences. Under optimized conditions, this assay exhibited a linear response to AFM1 in the range of 1-100 ng/mL and a limit of detection of 0.5 ng/mL was calculated. This proposed aptasensor was applied to milk samples spiked with a dilution series of AFM1, yielding satisfactory recoveries from 93.4 to 101.3%. These results demonstrated that this detection technique could be useful for high-throughput and quantitative determination of mycotoxin levels in milk and dairy products.
Collapse
Affiliation(s)
- Qinqin Qiao
- Laboratory of Quality and Safety Risk Assessment for Dairy Products of Ministry of Agriculture and Rural Affairs, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing, China
- College of Information Engineering, Fuyang Normal University, Fuyang, China
- Anhui Agricultural University, Hefei, China
| | - Xiaodong Guo
- Laboratory of Quality and Safety Risk Assessment for Dairy Products of Ministry of Agriculture and Rural Affairs, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing, China
- School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai, China
- Milk and Dairy Product Inspection Center of Ministry of Agriculture and Rural Affairs, Beijing, China
| | - Fang Wen
- Laboratory of Quality and Safety Risk Assessment for Dairy Products of Ministry of Agriculture and Rural Affairs, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing, China
- Milk and Dairy Product Inspection Center of Ministry of Agriculture and Rural Affairs, Beijing, China
| | - Lu Chen
- Laboratory of Quality and Safety Risk Assessment for Dairy Products of Ministry of Agriculture and Rural Affairs, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing, China
- Milk and Dairy Product Inspection Center of Ministry of Agriculture and Rural Affairs, Beijing, China
| | - Qingbiao Xu
- College of Animal Sciences and Technology, Huazhong Agricultural University, Wuhan, China
| | - Nan Zheng
- Laboratory of Quality and Safety Risk Assessment for Dairy Products of Ministry of Agriculture and Rural Affairs, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing, China
- Milk and Dairy Product Inspection Center of Ministry of Agriculture and Rural Affairs, Beijing, China
| | | | | | - Jiaqi Wang
- Laboratory of Quality and Safety Risk Assessment for Dairy Products of Ministry of Agriculture and Rural Affairs, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing, China
- Milk and Dairy Product Inspection Center of Ministry of Agriculture and Rural Affairs, Beijing, China
| |
Collapse
|
4
|
Zhou Y, Xiong S, Zhang K, Feng L, Chen X, Wu Y, Huang X, Xiong Y. Quantum bead-based fluorescence-linked immunosorbent assay for ultrasensitive detection of aflatoxin M 1 in pasteurized milk, yogurt, and milk powder. J Dairy Sci 2019; 102:3985-3993. [PMID: 30879825 DOI: 10.3168/jds.2018-16109] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Accepted: 01/23/2019] [Indexed: 01/08/2023]
Abstract
Herein, we reported a novel direct competitive fluorescence-linked immunosorbent assay (dcFLISA) for the ultrasensitive detection of aflatoxin M1 (AFM1) in pasteurized milk, yogurt, and milk powder using 150-nm quantum dot beads (QB) as the carrier of competing antigen. Large QB were applied to decrease the binding affinity of the competing antigen to antibody and enhance the fluorescent signal intensity. The aflatoxin B1 molecule was used as the surrogate of AFM1 to label with BSA on the surface of QB because of its 63% cross reaction to anti-AFM1 mAb. The binding affinity of the competing antigen to mAb was tuned by changing the labeled molar ratios of aflatoxin B1 to BSA. Through combining the advantages of QB as the carrier of the competing antigen, including low binding affinity to mAb and highly fluorescent signal output, the proposed dcFLISA exhibited an ultrahigh sensitivity for AFM1 detection, with a half-maximal inhibitory concentration of 3.15 pg/mL in 0.01 M phosphate-buffered saline solution (pH 7.4), which is substantially lower than that of the traditional horseradish peroxidase-based ELISA. The proposed method also exhibited very low detection limitations of 0.5, 0.6, and 0.72 pg/mL for real pasteurized milk, yogurt, and milk powder, respectively. These values are considerably below the maximum permissible level of the European Commission standard for AFM1 in dairy products. In summary, the proposed dcFLISA offers a novel strategy with an ultrahigh sensitivity for the routine monitoring of AFM1 in various dairy products.
Collapse
Affiliation(s)
- Yaofeng Zhou
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China; School of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
| | - Sicheng Xiong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China; School of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
| | - KangKang Zhang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China; School of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
| | - Lin Feng
- Key Laboratory of Functional Small Organic Molecule, Ministry of Education, Jiangxi Normal University, Nanchang 330022, P. R., China
| | - Xuelan Chen
- Key Laboratory of Functional Small Organic Molecule, Ministry of Education, Jiangxi Normal University, Nanchang 330022, P. R., China.
| | - Yuhao Wu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China; School of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
| | - Xiaolin Huang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China; School of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China; School of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China.
| |
Collapse
|
5
|
Chen W, Huang Z, Hu S, Peng J, Liu D, Xiong Y, Xu H, Wei H, Lai W. Invited review: Advancements in lateral flow immunoassays for screening hazardous substances in milk and milk powder. J Dairy Sci 2019; 102:1887-1900. [PMID: 30660416 DOI: 10.3168/jds.2018-15462] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2018] [Accepted: 11/11/2018] [Indexed: 12/17/2022]
Abstract
Dairy-related food safety outbreaks, such as food-borne pathogen contamination, mycotoxin contamination, and veterinary drug contamination, sometimes happen and have been reported all over the world, affecting human health and, in some cases, leading to death. Thus, rapid yet robust detection methods are needed to monitor milk and milk powder for the presence of hazardous substances. The lateral flow immunoassay (LFI) is widely used in onsite testing because of its rapidity, simplicity, and convenience. In this review, we describe some traditional LFI used to detect hazardous substances in milk and milk powder. Furthermore, we discuss recent advances in LFI that aim to improve sensitivity or detection efficiency. These advances include the use of novel label materials, development of signal amplification systems, design of multiplex detection systems, and the use of nucleic acid-based LFI.
Collapse
Affiliation(s)
- Wenyao Chen
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Zheng Huang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Song Hu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Juan Peng
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Daofeng Liu
- Jiangxi Province Center for Disease Control and Prevention, Nanchang 330047, China
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Hengyi Xu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Hua Wei
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Weihua Lai
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China.
| |
Collapse
|
6
|
Zhu C, Zhang G, Huang Y, Yang S, Ren S, Gao Z, Chen A. Dual-competitive lateral flow aptasensor for detection of aflatoxin B 1 in food and feedstuffs. JOURNAL OF HAZARDOUS MATERIALS 2018; 344:249-257. [PMID: 29055198 DOI: 10.1016/j.jhazmat.2017.10.026] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Revised: 10/04/2017] [Accepted: 10/12/2017] [Indexed: 06/07/2023]
Abstract
A novel dual-competitive lateral flow aptasensor (LFA) benefited from aptamer and lateral flow strips was first designed by using aflatoxin B1 (AFB1) as the model target. In this LFA assay, the target AFB1 competed with AFB1-hapten at T line for binding to Cy5-labeled AFB1 aptamer and the complementary strand competed with the target AFB1 for binding to Cy5-labeled AFB1 aptamer at C line. The ratio of their fluorescent intensities at the T line and C line (ST/SC ratio) was employed in order to increase the sensitivity for target AFB1 detection. This technique has the limit of detection (LOD) of 0.1ng/mL for AFB1 within the linear range from 0.1ng/mL to 1000ng/mL. Subsequently, the LFA approach was validated using 11 kinds of food and feedstuff samples with a simple aqueous extraction protocol. The test results with different naturally contaminated feedstuffs indicated a good correlation between this LFA and a commercial ELISA kit. The assay can be completed within 20min and its sensitivity, specificity and reproducibility are highly satisfactory. This is the first LFA that has been rigorously validated, which will be greatly beneficial to development of commercial aptamer-based biosensors for food safety, environmental analysis, particularly in clinical diagnosis.
Collapse
Affiliation(s)
- Chao Zhu
- Institute of Quality Standards and Testing Technology for Agro-products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, China; Key Laboratory of Agri-food Quality and Safety, Ministry of Agriculture, Beijing 100081, China
| | - Guilan Zhang
- Institute of Quality Standards and Testing Technology for Agro-products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, China; Key Laboratory of Agri-food Quality and Safety, Ministry of Agriculture, Beijing 100081, China
| | - Yafei Huang
- Institute of Quality Standards and Testing Technology for Agro-products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, China; Key Laboratory of Agri-food Quality and Safety, Ministry of Agriculture, Beijing 100081, China; College of Food Science and Technology, Hainan University, Haikou 570228,China
| | - Shuming Yang
- Institute of Quality Standards and Testing Technology for Agro-products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, China; Key Laboratory of Agri-food Quality and Safety, Ministry of Agriculture, Beijing 100081, China
| | - Shuyue Ren
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Health and Environment Medicine, Tianjin 300050, China
| | - Zhixian Gao
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Health and Environment Medicine, Tianjin 300050, China.
| | - Ailiang Chen
- Institute of Quality Standards and Testing Technology for Agro-products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, China; Key Laboratory of Agri-food Quality and Safety, Ministry of Agriculture, Beijing 100081, China.
| |
Collapse
|
7
|
Visual electrochemiluminescence biosensing of aflatoxin M1 based on luminol-functionalized, silver nanoparticle-decorated graphene oxide. Biosens Bioelectron 2017; 100:382-388. [PMID: 28950248 DOI: 10.1016/j.bios.2017.09.035] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Revised: 08/11/2017] [Accepted: 09/18/2017] [Indexed: 02/06/2023]
Abstract
A sensitive electrochemiluminescence (ECL) aptasensor for aflatoxin M1 (AFM1) detection by a closed bipolar electrode (BPE) array has been introduced. The thiolated AFM1 aptamer was immobilized on gold nanoparticle-coated magnetic Fe3O4 nanoparticles (Apt-GMNPs). Luminol-functionalized silver nanoparticle-decorated graphene oxide (GO-L-AgNPs) participates in π-π interactions with the unpaired bases of the immobilized aptamer (Apt-GMNPs-GO-L-AgNPs). After the Apt-GMNPs-GO-L-AgNPs were introduced to a gold anodic BPE array, the individual electrodes were subjected to different concentrations of AFM1. Upon the interaction of AFM1 with the aptamers, the GO-L-AgNPs detach from the aptamer; the resulting ECL of luminol and H2O2 at the anodic poles is monitored using a photomultiplier tube (PMT) or smartphone, and the images are analyzed using ImageJ software. This process triggers thionine reduction at the cathodic poles. Under the optimal conditions obtained by a face-centered central composite design (FCCD), the PMT-based detection of the BPE-ECL aptasensor exhibit a linear response over a wide dynamic range from 5 to 150ngmL-1, with a detection limit of 0.01ngmL-1. Additionally, smartphone-based detection shows a linear relationship between the ECL image gray value and the logarithmic concentration of the AFM1 target over a range of 10-200ngmL-1, with a detection limit of 0.05ngmL-1. Furthermore, the BPE-ECL aptasensor was successfully used to detect AFM1 in milk complex media without any serious interferences with reliable reproducibility (average relative standard deviation (RSD = 2.3%)). This smartphone-based detection opens a new horizon for bioanalysis that does not require a trained technician to operate and is a promising technology for point-of-care testing.
Collapse
|
8
|
Matabaro E, Ishimwe N, Uwimbabazi E, Lee BH. Current Immunoassay Methods for the Rapid Detection of Aflatoxin in Milk and Dairy Products. Compr Rev Food Sci Food Saf 2017; 16:808-820. [DOI: 10.1111/1541-4337.12287] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 06/11/2017] [Accepted: 06/14/2017] [Indexed: 12/13/2022]
Affiliation(s)
- Emmanuel Matabaro
- Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, School of Biotechnology; Jiangnan Univ.; Wuxi Jiangsu 214122 China
| | - Nestor Ishimwe
- Hefei Natl. Laboratory for Physical Sciences at Microscale and School of Life Sciences; Univ. of Science and Technology of China; Hefei Anhui 230027 China
- the Dept. of Chemistry, College of Science and Technology; Univ. of Rwanda; Rwanda
| | - Eric Uwimbabazi
- School of Food Science; Jiangnan Univ.; Wuxi Jiangsu 214122 China
| | - Byong H. Lee
- Dept. of Microbiology and Immunology; McGill Univ.; Montreal QC H3A 2B4 Canada
- Dept. of Food Science and Biotechnology; Kangwon Natl. Univ.; Chuncheon 200701 South Korea
| |
Collapse
|
9
|
Cheng S, Yang Y, Ni X, Peng J, Lai W. Fluorescent microspheres lateral flow assay for sensitive detection of the milk allergen casein. FOOD AGR IMMUNOL 2017. [DOI: 10.1080/09540105.2017.1325841] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Affiliation(s)
- Song Cheng
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, People’s Republic of China
| | - Yajie Yang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, People’s Republic of China
| | - Xiaoqin Ni
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, People’s Republic of China
| | - Juan Peng
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, People’s Republic of China
| | - Weihua Lai
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, People’s Republic of China
| |
Collapse
|
10
|
Hassan SM, Sultana B, Iqbal M, Naz S, Abbas M. Anti-aflatoxigenic activity of Punica granatum and Ziziphus jujuba leaves against Aspergillus parasiticus inoculated poultry feed: Effect of storage conditions. BIOCATALYSIS AND AGRICULTURAL BIOTECHNOLOGY 2017. [DOI: 10.1016/j.bcab.2017.02.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
11
|
Berthiller F, Brera C, Iha M, Krska R, Lattanzio V, MacDonald S, Malone R, Maragos C, Solfrizzo M, Stranska-Zachariasova M, Stroka J, Tittlemier S. Developments in mycotoxin analysis: an update for 2015-2016. WORLD MYCOTOXIN J 2017. [DOI: 10.3920/wmj2016.2138] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
This review summarises developments in the determination of mycotoxins over a period between mid-2015 and mid-2016. Analytical methods to determine aflatoxins, Alternaria toxins, ergot alkaloids, fumonisins, ochratoxins, patulin, trichothecenes and zearalenone are covered in individual sections. Advances in proper sampling strategies are discussed in a dedicated section, as are methods used to analyse botanicals and spices and newly developed liquid chromatography mass spectrometry based multi-mycotoxin methods. This critical review aims to briefly discuss the most important recent developments and trends in mycotoxin determination as well as to address limitations of presented methodologies.
Collapse
Affiliation(s)
- F. Berthiller
- Christian Doppler Laboratory for Mycotoxin Metabolism and Center for Analytical Chemistry, Department of Agrobiotechnology (IFA-Tulln), University of Natural Resources and Life Sciences, Vienna, Konrad Lorenz Str. 20, 3430 Tulln, Austria
| | - C. Brera
- Istituto Superiore di Sanità, Department of Veterinary Public Health and Food Safety – GMO and Mycotoxins Unit, Viale Regina Elena 299, 00161 Rome, Italy
| | - M.H. Iha
- Adolfo Lutz Institute of Ribeirão Preto, Nucleous of Chemistry and Bromatology Science, Rua Minas 866, Ribeirão Preto, SP 14085-410, Brazil
| | - R. Krska
- Christian Doppler Laboratory for Mycotoxin Metabolism and Center for Analytical Chemistry, Department of Agrobiotechnology (IFA-Tulln), University of Natural Resources and Life Sciences, Vienna, Konrad Lorenz Str. 20, 3430 Tulln, Austria
| | - V.M.T. Lattanzio
- National Research Council, Institute of Sciences of Food Production, Via Amendola 122/o, 700126 Bari, Italy
| | - S. MacDonald
- Fera Science Ltd., Sand Hutton, York YO41 1LZ, United Kingdom
| | - R.J. Malone
- Trilogy Analytical Laboratory, 870 Vossbrink Dr, Washington, MO 63090, USA
| | - C. Maragos
- USDA-ARS-NCAUR, Mycotoxin Prevention and Applied Microbiology Research Unit, 1815 N. University St, Peoria, IL 61604, USA
| | - M. Solfrizzo
- National Research Council, Institute of Sciences of Food Production, Via Amendola 122/o, 700126 Bari, Italy
| | - M. Stranska-Zachariasova
- Department of Food Analysis and Nutrition, Faculty of Food and Biochemical Technology, University of Chemistry and Technology, Prague 6, Czech Republic
| | - J. Stroka
- European Commission, Joint Research Centre, Retieseweg, 2440 Geel, Belgium
| | - S.A. Tittlemier
- Canadian Grain Commission, Grain Research Laboratory, 1404-303 Main St, Winnipeg, MB R3C 3G8, Canada
| |
Collapse
|
12
|
Sharma A, Catanante G, Hayat A, Istamboulie G, Ben Rejeb I, Bhand S, Marty JL. Development of structure switching aptamer assay for detection of aflatoxin M1 in milk sample. Talanta 2016; 158:35-41. [PMID: 27343575 DOI: 10.1016/j.talanta.2016.05.043] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 05/07/2016] [Accepted: 05/13/2016] [Indexed: 01/28/2023]
Abstract
The discovery of in-vitro systematic evolution of ligands by exponential enrichment (SELEX) process has considerably broaden the utility of aptamer as bio-recognition element, providing the high binding affinity and specificity against the target analytes. Recent research has focused on the development of structure switching signaling aptamer assay, transducing the aptamer- target recognition event into an easily detectable signal. In this paper, we demonstrate the development of structure switching aptamer assay for determination of aflatoxin M1 (AFM1) employing the quenching-dequenching mechanism. Hybridization of fluorescein labelled anti-AFM1 aptamer (F-aptamer) with TAMRA labelled complementary sequences (Q-aptamer) brings the fluorophore and the quencher into close proximity, which results in maximum fluorescence quenching. On addition of AFM1, the target induced conformational formation of antiparallel G-quadruplex aptamer-AFM1 complex results in fluorescence recovery. Under optimized experimental conditions, the developed method showed the good linearity with limit of detection (LOD) at 5.0ngkg(-1) for AFM1. The specificity of the sensing platform was carefully investigated against aflatoxin B1 (AFB1) and ochratoxin A (OTA). The developed assay platform showed the high specificity towards AFM1. The practical application of the developed aptamer assay was verified for detection of AFM1 in spiked milk samples. Good recoveries were obtained in the range from 94.40% to 95.28% (n=3) from AFM1 spiked milk sample.
Collapse
Affiliation(s)
- Atul Sharma
- BAE Laboratory, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan 66860, France; Biosensor Lab, Department of Chemistry, BITS, Pilani, K. K. Birla Goa Campus, Zuarinagar, Goa 403726, India
| | - Gaëlle Catanante
- BAE Laboratory, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan 66860, France
| | - Akhtar Hayat
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS Institute of Information Technology (CIIT), Lahore 54000, Pakistan; BAE Laboratory, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan 66860, France
| | - Georges Istamboulie
- BAE Laboratory, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan 66860, France
| | - Ines Ben Rejeb
- Biocatalysis and Industrial Enzymes Group, Laboratory of Microbial Ecology and Technology, Carthage University, National Institute of Applied Sciences and Technology, BP 676, 1080 Tunis, Tunisia; BAE Laboratory, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan 66860, France
| | - Sunil Bhand
- Biosensor Lab, Department of Chemistry, BITS, Pilani, K. K. Birla Goa Campus, Zuarinagar, Goa 403726, India
| | - Jean Louis Marty
- BAE Laboratory, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan 66860, France.
| |
Collapse
|