1
|
Development of fluorescence-linked immunosorbent assay for rapid detection of Staphylococcus aureus. Appl Microbiol Biotechnol 2024; 108:2. [PMID: 38153552 DOI: 10.1007/s00253-023-12836-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 09/22/2023] [Accepted: 09/30/2023] [Indexed: 12/29/2023]
Abstract
Staphylococcus aureus is a major pathogen that causes infections and life-threatening diseases. Although antibiotics, such as methicillin, have been used, methicillin-resistant S. aureus (MRSA) causes high morbidity and mortality rates, and conventional detection methods are difficult to be used because of time-consuming process. To control the spread of S. aureus, a development of a rapid and simple detection method is required. In this study, we generated a fluorescent anti-S. aureus antibody, and established a novel fluorescence-linked immunosorbent assay (FLISA)-based S. aureus detection method. The method showed high sensitivity and low limit of detection toward MRSA detection. The assay time for FLISA was 5 h, which was faster than that of conventional enzyme-linked immunosorbent assay (ELISA) or rapid ELISA. Moreover, the FLISA-based detection method was applied to diagnose clinically isolated MRSA samples that required only 5.3 h of preincubation. The FLISA method developed in this study can be widely applied as a useful tool for convenient S. aureus detection. KEY POINTS: • A fluorescence-linked immunosorbent assay-based S. aureus detection method • Simultaneous quantification of a maximum of 96 samples within 5 h • Application of the novel system to diagnosis clinical isolates.
Collapse
|
2
|
Staphylococcus aureus Isolated From Traditional Artisanal Raw Milk Cheese from Southern Brazil: Diversity, Virulence, and Antimicrobial Resistance Profile. J Food Prot 2024; 87:100285. [PMID: 38697483 DOI: 10.1016/j.jfp.2024.100285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 04/19/2024] [Accepted: 04/23/2024] [Indexed: 05/05/2024]
Abstract
Staphylococcus aureus is one of the primary pathogenic agents found in cheeses produced with raw milk. Some strains of S. aureus are enterotoxigenic, possessing the ability to produce toxins responsible for staphylococcal food poisoning when present in contaminated foods. This study aimed to genotypically characterize, assess the antimicrobial resistance profile, and examine the enterotoxigenic potential of strains of S. aureus isolated from artisanal colonial cheese. Additionally, a bacterial diversity assessment in the cheeses was conducted by sequencing the 16S rRNA gene. The metataxomic profile revealed the presence of 68 distinct species in the cheese samples. Fifty-seven isolates of S. aureus were identified, with highlighted resistance to penicillin in 33% of the isolates, followed by clindamycin (28%), erythromycin (26%), and tetracycline (23%). The evaluated strains also exhibited inducible resistance to clindamycin, with nine isolates considered multidrug-resistant (MDR). The agr type I was the most prevalent (62%) among the isolates, followed by agr type II (24%). Additionally, ten spa types were identified. Although no enterotoxins and their associated genes were detected in the samples and isolates, respectively, the Panton-Valentine leukocidin gene (lukS-lukF) was found in 39% of the isolates. The presence of MDR pathogens in the artisanal raw milk cheese production chain underscores the need for quality management to prevent the contamination and dissemination of S. aureus strains.
Collapse
|
3
|
Rationally designed protein A surface molecularly imprinted magnetic nanoparticles for the capture and detection of Staphylococcus aureus. J Mater Chem B 2024. [PMID: 38757517 DOI: 10.1039/d4tb00392f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Staphylococcus aureus (S. aureus), a commensal organism found on the human skin, is commonly associated with nosocomial infections and exhibits virulence mediated by toxins and resistance to antibiotics. The global threat of antibiotic resistance has necessitated antimicrobial stewardship to improve the safe and appropriate use of antimicrobials; hence, there is an urgent demand for the advanced, cost-effective, and rapid detection of specific bacteria. In this regard, we aimed to selectively detect S. aureus using surface molecularly imprinted magnetic nanoparticles templated with a well-known biomarker protein A, specific to S. aureus. Herein, a highly selective surface molecularly imprinted polymeric thin layer was created on ∼250 nm magnetic nanoparticles (MNPs) through the immobilization of protein A to aldehyde functionalized MNPs, followed by monomer polymerization and template washing. This study employs the rational selection of monomers based on their computationally predicted binding affinity to protein A at multiple surface residues. The resulting MIPs from rationally selected monomer combinations demonstrated an imprinting factor as high as ∼5. Selectivity studies revealed MIPs with four-fold higher binding capacity (BC) to protein A than other non-target proteins, such as lysozyme and serum albumin. In addition, it showed significant binding to S. aureus, whereas negligible binding to other non-specific Gram-negative, i.e. Escherichia coli (E. coli), Pseudomonas aeruginosa (P. aeruginosa), and Gram-positive, i.e. Bacillus subtilis (B. subtilis), bacteria. This MIP was employed for the capture and specific detection of fluorescently labeled S. aureus. Quantitative detection was performed using a conventional plate counting technique in a linear detection range of 101-107 bacterial cells. Remarkably, the MIPs also exhibited approximately 100% cell recovery from milk samples spiked with S. aureus (106 CFU mL-1), underscoring its potential as a robust tool for sensitive and accurate bacterial detection in dairy products. The developed MIP exhibiting high affinity and selective binding to protein A finds its potential applications in the magnetic capture and selective detection of protein A as well as S. aureus infections and contaminations.
Collapse
|
4
|
Double-Enhanced Photothermal Lateral Flow Biosensor Based on Dual Gold Nanoparticle Conjugates. ACS Sens 2024. [PMID: 38758028 DOI: 10.1021/acssensors.3c02329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Bacterial toxins emerge as the primary triggers of foodborne illnesses, posing a significant threat to human health. To ensure food safety, it is imperative to implement point-of-care testing methods. Lateral flow biosensors (LFBs) based on gold nanoparticles (GNPs) have been commonly used for rapid detection, but their applicationis limited by low sensitivity. Based on the localized surface plasmon resonance and photothermal effect of dual gold nanoparticle conjugates (DGNPs), we developed a smartphone-integrated photothermal LFB (PLFB) with double-enhanced colorimetric and photothermal sensitivity. Through numerical simulations, we verified that DGNPs have significantly enhanced photothermal performance compared to single 15 nm GNPs (SGNPs), and applied DGNPs in PLFB for the detection of staphylococcus enterotoxin A (SEA). The colorimetric and photothermal limits of detection of DGNPs-based PLFB for SEA were 0.091 and 0.0038 ng mL-1, respectively. Compared with the colorimetric detection of the SGNPs-based LFB, the colorimetric detection sensitivity of the DGNPs-based PLFB was increased by 10.7 times, and the photothermal detection sensitivity was further improved by 255.3 times. Moreover, the PLFB exhibits robust reproducibility and exceptional specificity and is applicable for detecting SEA in milk samples. This smartphone-integrated PLFB based on DGNPs allows users to detect toxins simply, conveniently, and quickly and has huge application potential in the field of food safety.
Collapse
|
5
|
A pomegranate seed-structured nanozyme-based colorimetric immunoassay for highly sensitive and specific biosensing of Staphylococcus aureus. Analyst 2024; 149:563-570. [PMID: 38099463 DOI: 10.1039/d3an01621h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2024]
Abstract
Staphylococcus aureus (S. aureus) infections are a serious threat to human health. The development of rapid and sensitive detection methods for pathogenic bacteria is crucial for accurate drug administration. In this research, by combining the advantages of enzyme-linked immunosorbent assay (ELISA), we synthesized nanozymes with high catalytic performance, namely pomegranate seed-structured bimetallic gold-platinum nanomaterials (Ps-PtAu NPs), which can catalyze a colorless TMB substrate into oxidized TMB (oxTMB) with blue color to achieve colorimetric analysis of S. aureus. Under the optimal conditions, the proposed biosensor could quantitatively detect S. aureus at levels ranging from 1.0 × 101 to 1.0 × 106 CFU mL-1 with a limit of detection (LOD) of 3.9 CFU mL-1. Then, an integrated color picker APP on a smartphone enables on-site point-of-care testing (POCT) of S. aureus with LOD as low as 1 CFU mL-1. Meanwhile, the proposed biosensor is successfully applied to the detection of S. aureus in clinical samples with high sensitivity and specificity.
Collapse
|
6
|
A comprehensive review on the detection of Staphylococcus aureus enterotoxins in food samples. Compr Rev Food Sci Food Saf 2024; 23:e13264. [PMID: 38284582 DOI: 10.1111/1541-4337.13264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 10/12/2023] [Accepted: 10/15/2023] [Indexed: 01/30/2024]
Abstract
Staphylococcal enterotoxins (SEs), the major virulence factors of Staphylococcus aureus, cause a wide range of food poisoning and seriously threaten human health by infiltrating the food supply chain at different phases of manufacture, processes, distribution, and market. The significant prevalence of Staphylococcus aureus calls for efficient, fast, and sensitive methods for the early detection of SEs. Here, we provide a comprehensive review of the hazards of SEs in contaminated food, the characteristic and worldwide regulations of SEs, and various detection methods for SEs with extensive comparison and discussion of benefits and drawbacks, mainly including biological detection, genetic detection, and mass spectrometry detection and biosensors. We highlight the biosensors for the screening purpose of SEs, which are classified according to different recognition elements such as antibodies, aptamers, molecularly imprinted polymers, T-cell receptors, and transducers such as optical, electrochemical, and piezoelectric biosensors. We analyzed challenges of biosensors for the monitoring of SEs and conclude the trends for the development of novel biosensors should pay attention to improve samples pretreatment efficiency, employ innovative nanomaterials, and develop portable instruments. This review provides new information and insightful commentary, important to the development and innovation of further detection methods for SEs in food samples.
Collapse
|
7
|
Dual-Toehold-Probe-Mediated Exonuclease-III-Assisted Signal Recycles Integrated with CHA for Detection of mecA Gene Using a Personal Glucose Meter in Skin and Soft Tissue Infection. J Microbiol Biotechnol 2023; 33:1692-1697. [PMID: 37734933 PMCID: PMC10772588 DOI: 10.4014/jmb.2306.06037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 08/04/2023] [Accepted: 08/10/2023] [Indexed: 09/23/2023]
Abstract
Staphylococcus aureus integrated with mecA gene, which codes for penicillin-binding protein 2a, is resistant to all penicillins and other beta-lactam antibiotics, resulting in poor treatment expectations in skin and soft tissue infections. The development of a simple, sensitive and portable biosensor for mecA gene analysis in S. aureus is urgently needed. Herein, we propose a dual-toehold-probe (sensing probe)-mediated exonuclease-III (Exo-III)-assisted signal recycling for portable detection of the mecA gene in S. aureus. When the target mecA gene is present, it hybridizes with the sensing probe, initiating Exo III-assisted dual signal recycles, which in turn release numerous "3" sequences. The released "3" sequences initiate catalytic hairpin amplification, resulting in the fixation of a sucrase-labeled H2 probe on the surface of magnetic beads (MBs). After magnet-based enrichment of an MB-H1-H2-sucrase complex and removal of a liquid supernatant containing free sucrase, the complex is then used to catalyze sucrose to glucose, which can be quantitatively detected by a personal glucose meter. With a limit of detection of 4.36 fM for mecA gene, the developed strategy exhibits high sensitivity. In addition, good selectivity and anti-interference capability were also attained with this method, making it promising for antibiotic tolerance analysis at the point-of-care.
Collapse
|
8
|
Isothermal Amplification and CRISPR/Cas12a-System-Based Assay for Rapid, Sensitive and Visual Detection of Staphylococcus aureus. Foods 2023; 12:4432. [PMID: 38137236 PMCID: PMC10742561 DOI: 10.3390/foods12244432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 11/21/2023] [Accepted: 11/30/2023] [Indexed: 12/24/2023] Open
Abstract
Staphylococcus aureus exists widely in the natural environment and is one of the main food-borne pathogenic microorganisms causing human bacteremia. For safe food management, a rapid, high-specificity, sensitive method for the detection of S. aureus should be developed. In this study, a platform for detecting S. aureus (nuc gene) based on isothermal amplification (loop-mediated isothermal amplification-LAMP, recombinase polymerase amplification-RPA) and the clustered regularly interspaced short palindromic repeats (CRISPR) and CRISPR-associated (Cas12a) proteins system (LAMP, RPA-CRISPR/Cas12a) was proposed. In this study, the LAMP, RPA-CRISPR/Cas12a detection platform and immunochromatographic test strip (ICS) were combined to achieve a low-cost, simple and visualized detection of S. aureus. The limit of visual detection was 57.8 fg/µL of nuc DNA and 6.7 × 102 CFU/mL of bacteria. Moreover, the platform could be combined with fluorescence detection, namely LAMP, RPA-CRISPR/Cas12a-flu, to establish a rapid and highly sensitive method for the detection of S. aureus. The limit of fluorescence detection was 5.78 fg/µL of genomic DNA and 67 CFU/mL of S. aureus. In addition, this detection platform can detect S. aureus in dairy products, and the detection time was ~40 min. Consequently, the isothermal amplification CRISPR/Cas12a platform is a useful tool for the rapid and sensitive detection of S. aureus in food.
Collapse
|
9
|
Biological effect abundance analysis of hemolytic pathogens based on engineered biomimetic sensor. Biosens Bioelectron 2023; 237:115502. [PMID: 37423067 DOI: 10.1016/j.bios.2023.115502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 06/23/2023] [Accepted: 06/26/2023] [Indexed: 07/11/2023]
Abstract
Conventional pathogen detection strategies based on the molecular structure or chemical characteristics of biomarkers can only provide the "physical abundance" of microorganisms, but cannot reflect the "biological effect abundance" in the true sense. To address this issue, we report an erythrocyte membrane-encapsulated biomimetic sensor cascaded with CRISPR-Cas12a (EMSCC). Taking hemolytic pathogens as the target model, we first constructed an erythrocyte membrane-encapsulated biomimetic sensor (EMS). Only hemolytic pathogens with biological effects can disrupt the erythrocyte membrane (EM), resulting in signal generation. Then the signal was amplified by cascading CRISPR-Cas12a, and more than 6.67 × 104-fold improvement in detection sensitivity compared to traditional erythrocyte hemolysis assay was achieved. Notably, compared with polymerase chain reaction (PCR) or enzyme linked immunosorbent assay (ELISA)-based quantification methods, EMSCC can sensitively respond to the pathogenicity change of pathogens. For the detection of simulated clinical samples based on EMSCC, we obtained an accuracy of 95% in 40 samples, demonstrating its potential clinical value.
Collapse
|
10
|
Use of nano titanium hydroxide and nano zirconium hydroxide fixed filter paper for rapid detection of Staphylococcus aureus in dairy products by PCR without pre-enrichment. Food Control 2023. [DOI: 10.1016/j.foodcont.2023.109664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
11
|
Quantitative risk assessment for type A staphylococcal enterotoxin poisoning due to consumption of Minas Frescal cheese in Brazil. INT J DAIRY TECHNOL 2022. [DOI: 10.1111/1471-0307.12924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
12
|
A new method for quantitative analysis of M13 bacteriophage by atomic force microscopy. Synth Syst Biotechnol 2022; 7:1066-1072. [PMID: 35891946 PMCID: PMC9293941 DOI: 10.1016/j.synbio.2022.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 06/29/2022] [Accepted: 07/07/2022] [Indexed: 11/27/2022] Open
Abstract
Quantitative analysis is essential for virus research, especially in determining the virus titer. The classical method plaque assay is time-consuming, complex, and difficult for the phages that cannot form apparent plaque on the solid medium. In order to realize rapid and effective detection, a new method combining atomic force microscopy (AFM) observation and mathematical calculation is established. In this research, M13 phages with an appropriate dilution ratio were observed and counted by AFM. Based on the counting results, the titer of M13 phages can be calculated simply through mathematical substitution. Instead of cultivating overnight in plaque assay, this new method can be implemented within a few hours. Moreover, it is a method that can achieve visualization for titer determination and have the potential to determine the phages that fail to form apparent plaque, which is significant in virus quantitative assessment.
Collapse
|
13
|
Naked-eye detection of Staphylococcus aureus in powdered milk and infant formula using gold nanoparticles. J Microbiol Methods 2022; 201:106578. [PMID: 36108985 DOI: 10.1016/j.mimet.2022.106578] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Revised: 09/07/2022] [Accepted: 09/07/2022] [Indexed: 12/27/2022]
Abstract
Nonspecific binding of proteins from complex food matrices is a significant challenge associated with a biosensor using gold nanoparticles (AuNPs). To overcome this, we developed an efficient EDTA chelating treatment to denature milk proteins and prevent their adsorption on AuNPs. The use of EDTA to solubilize proteins enabled a sensitive label-free apta-sensor platform for colorimetric detection of Staphylococcus aureus in milk and infant formula. In the assay, S. aureus depleted aptamers from the test solution, and the reduction of aptamers enabled aggregation of AuNPs upon salt addition, a process characterized by a color change from red to purple. Under optimized conditions, S. aureus could be visually detected within 30 min with the detection limit of 7.5 × 104 CFU/mL and 8.4 × 104 CFU/mL in milk and infant formula, respectively. The EDTA treatment provides new opportunities for monitoring milk contamination and may prove valuable for biosensor point-of-need applications.
Collapse
|
14
|
Multiple amplification-based fluorometric aptasensor for highly sensitive detection of Staphylococcus aureus. Appl Microbiol Biotechnol 2022; 106:6733-6743. [PMID: 36058939 DOI: 10.1007/s00253-022-12057-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/27/2022] [Accepted: 06/28/2022] [Indexed: 11/02/2022]
Abstract
Rapid and accurate detection and identification of Staphylococcus aureus (S. aureus) are of great significance for food safety, environmental monitoring, early clinical diagnosis, and prevention of the spread of drug-resistant bacteria. Herein, we design a fluorometric aptasensor for ultra-sensitive, specific, and rapid detection of S. aureus. The apasensor combines the enrichment and separation of magnetic nanoparticles (MNPs), the biotin-streptavidin conjugation system, and a single S. aureus can release four signaling probes for signal amplification. Aptamer acts as a specific biorecognition element of S. aureus. Four FAM-labeled partially complementary sequences (FAM-pcDNAs) were used as signaling probes. The aptamers were sequential hybridized with the four FAM-pcDNAs to form aptamer&pcDNAs, which were then bound to MNPs via the biotin-streptavidin. When the aptamer specifically recognizes and binds to S. aureus, the FAM-pcDNAs signaling probes are replaced and released into the supernatant. The concentration of S. aureus can be quantified by measuring the fluorescence intensity (λexc/em = 492/520 nm) of the replaced signaling probe FAM-pcDNAs. The results show that the proposed fluorometric aptasensor displays good specificity, ultra-high sensitivity (1.23 cfu/mL), wide linear range (1 ~ 108 cfu/mL), and fast detection speed (~ 1.5 h). The recovery test verifies further that the proposed fluorometric aptasensor can detect S. aureus in spiked blood samples. Since aptamers are easy to customize, we believe that fluorometric aptasensors based on multiple amplification have broad prospects in the construction of practical high-performance biosensors for bacterial detection. KEY POINTS: • Multiple amplification-based fluorometric aptasensor for S. aureus is developed • The aptasensor displays high specificity with a LOD of 1.23 CFU/mL • The aptasensor can directly detect S. aureus in spiked blood samples.
Collapse
|
15
|
Unveiling the underpinnings of various non-conventional ELISA variants: a review article. Expert Rev Mol Diagn 2022; 22:761-774. [PMID: 36004453 DOI: 10.1080/14737159.2022.2117615] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Enzyme-linked immunosorbent assay (ELISA) is a key bio-analytical technique used for the detection of a large array of antigenic substances of scientific, clinical, food safety, and environmental importance. The assay primarily involves capturing and detecting target analytes using specific antigen-antibody interactions. The wide usage of ELISA shoulders on its high specificity and reproducibility. Notwithstanding, the conventional microwell plate-based format of ELISA has some major drawbacks, such as long assay time (4 - 18 h), large sample volumes requirement (100 - 200 μL), lack of multiplicity, and burdensome procedures that limit its utility in rapid and affordable diagnostics. AREAS COVERED Here, we reviewed microfluidic-ELISA, paper-ELISA, aptamer-ELISA, and those based on novel incubation such as heat-ELISA, pressure-ELISA, microwave-ELISA, and sound-ELISA. Further, the current trends and future prospects of these ELISA protocols in clinical diagnostics are discussed. EXPERT OPINION The reviewed non-conventional ELISA formats are relatively rapid, require low reagent volumes, are multiplexable, and could be performed in a low-cost setup. In our opinion, these non-conventional variants of ELISA are on a par with the conventional format for clinical diagnostics and fundamental biological research and hold added clinical translational potential for quick, inexpensive, and convenient measurements.
Collapse
|
16
|
An ultrasensitive and dual-recognition SERS biosensor based on Fe3O4@Au-Teicoplanin and aptamer functionalized Au@Ag nanoparticles for detection of Staphylococcus aureus. Talanta 2022; 250:123648. [DOI: 10.1016/j.talanta.2022.123648] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 05/30/2022] [Accepted: 06/01/2022] [Indexed: 12/30/2022]
|
17
|
Recent Advances in Aptasensors For Rapid and Sensitive Detection of Staphylococcus Aureus. Front Bioeng Biotechnol 2022; 10:889431. [PMID: 35677308 PMCID: PMC9169243 DOI: 10.3389/fbioe.2022.889431] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 04/12/2022] [Indexed: 12/30/2022] Open
Abstract
The infection of Staphylococcus aureus (S.aureus) and the spread of drug-resistant bacteria pose a serious threat to global public health. Therefore, timely, rapid and accurate detection of S. aureus is of great significance for food safety, environmental monitoring, clinical diagnosis and treatment, and prevention of drug-resistant bacteria dissemination. Traditional S. aureus detection methods such as culture identification, ELISA, PCR, MALDI-TOF-MS and sequencing, etc., have good sensitivity and specificity, but they are complex to operate, requiring professionals and expensive and complex machines. Therefore, it is still challenging to develop a fast, simple, low-cost, specific and sensitive S. aureus detection method. Recent studies have demonstrated that fast, specific, low-cost, low sample volume, automated, and portable aptasensors have been widely used for S. aureus detection and have been proposed as the most attractive alternatives to their traditional detection methods. In this review, recent advances of aptasensors based on different transducer (optical and electrochemical) for S. aureus detection have been discussed in details. Furthermore, the applications of aptasensors in point-of-care testing (POCT) have also been discussed. More and more aptasensors are combined with nanomaterials as efficient transducers and amplifiers, which appears to be the development trend in aptasensors. Finally, some significant challenges for the development and application of aptasensors are outlined.
Collapse
|
18
|
Quantum dot bead-based competitive immunochromatographic assay for enterotoxin aureus A detection in pasteurized milk. J Dairy Sci 2022; 105:4938-4945. [DOI: 10.3168/jds.2021-21568] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 03/02/2022] [Indexed: 12/15/2022]
|
19
|
Specific and ultrasensitive detection of Staphylococcus aureus with a catechol-chitosan redox capacitor based electrochemical aptasensor. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116357] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
20
|
Presence and growth prediction of Staphylococcus spp. and Staphylococcus aureus in Minas Frescal cheese, a soft fresh cheese produced in Brazil. J Dairy Sci 2021; 104:12312-12320. [PMID: 34593231 DOI: 10.3168/jds.2021-20633] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 08/18/2021] [Indexed: 11/19/2022]
Abstract
Physical-chemical characteristics of Minas Frescal cheese (MFC) favor the growth of Staphylococcus spp. and allow the production of enterotoxins by specific strains. Here, we aimed to characterize the physical-chemical aspects (pH, storage temperature, and salt content) and the presence of Staphylococcus spp. in MFC samples (n = 50) to support a modeling study for the growth by this microorganism. Coagulase-positive staphylococci isolates were obtained and subjected to PCR assays to identify them as Staphylococcus aureus (nuc) and to detect staphylococcal enterotoxin-related genes (sea, seb, sec, sed, see). Staphylococcus aureus growth kinetics (maximum growth rate, Grmax, and lag time) were predicted based on ComBase model and MFC physical-chemical aspects. Mean counts of Staphylococcus spp. ranged from 3.3 to 6.7 log cfu/g, indicating poor hygiene practices during production. Selected isolates (n = 10) were identified as S. aureus, but none presented classical enterotoxin-related genes. pH, temperature, and salt content ranged from 5.80 to 6.62, 5°C to 12°C, and 0.85% to 1.70%, respectively. The Grmax values ranged from 0.012 to 0.419 log cfu/g per h. Independent of the storage temperature, the lowest Grmax values (0.012 to 0.372 log cfu/h) were obtained at pH 5.80 associated with salt content of 1.7%; independent of the pH and salt content, the best temperature to avoid staphylococcal growth was 7.5°C. Hygienic conditions during MFC production must be adopted to avoid staphylococcal contamination, and storage at temperatures lower than 7.5°C can prevent staphylococcal growth and the potential production of enterotoxins.
Collapse
|
21
|
Aptasensors for Staphylococcus aureus Risk Assessment in Food. Front Microbiol 2021; 12:714265. [PMID: 34603242 PMCID: PMC8483178 DOI: 10.3389/fmicb.2021.714265] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 08/17/2021] [Indexed: 12/30/2022] Open
Abstract
Staphylococcus aureus (S. aureus) is the top ordinary pathogen causing epidemic and food poisoning. The authentication of S. aureus has great significance for pathologic diagnosis and food hygiene supervision. Various biosensor methods have been established for identification. This paper reviews the research progress of aptasensors for S. aureus detection, focusing on the classification of aptamer technologies, including optical aptasensors and electrochemical aptasensors. Furthermore, the feasibility and future challenges of S. aureus detection for aptamer assays are discussed. Combining aptasensors with nanomaterials appears to be the developing trend in aptasensors.
Collapse
|
22
|
Highly Sensitive Fluorescence Assay of Enterotoxin A in Milk Using Carbon Quantum Dots as a Fluorophore. FOOD ANAL METHOD 2021. [DOI: 10.1007/s12161-021-02009-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
23
|
A tetravalent single-chain variable fragment antibody for the detection of staphylococcal enterotoxin A. J Zhejiang Univ Sci B 2021; 22:305-309. [PMID: 33835764 DOI: 10.1631/jzus.b2000661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Staphylococcal enterotoxin A (SEA) synthesized by Staphylococcus aureus is a foodborne and heat-stable toxin, which is a great threat to human health (Pexaraet al., 2010). Highly sensitive antibodies are a key factor in the immunological detection of SEA, which is one of the most effective ways to detect SEA because of its accuracy, agility, and efficiency (Nouri et al., 2018). In this study, we constructed a tetravalent anti-SEA antibody gene by linking the tetramerization domain of human p53 to the C-terminus of the anti-SEA single-chain variable fragment (scFv), which was then transformed into Escherichia coli BL21 (DE3) for the production of a SEA-specific tetravalent antibody. Successful expression of the tetravalent antibody was determined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and western blot. An indirect non-competitive enzyme-linked immunosorbent assay (ELISA) revealed that the tetravalent antibody exhibited SEA-specific binding activity. A sandwich ELISA demonstrated that compared to the scFv monomer, the tetravalent antibody was more sensitive in detecting SEA. Molecular docking analysis revealed that the SEA interacted with the scFv mainly on the opposite side of the residue linked to p53. Thus, this study indicated that genetically engineered tetramerization is a potential way to improve the sensitivity of SEA-specific scFv.
Collapse
|
24
|
Detection of Staphylococcus aureus Enterotoxin A (SEA) Using Dot-ELISA in Milk Samples. JOURNAL OF MEDICAL MICROBIOLOGY AND INFECTIOUS DISEASES 2020. [DOI: 10.29252/jommid.8.4.132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
|
25
|
Electrochemical immunosensor for determination of Staphylococcus aureus bacteria by IgY immobilized on glassy carbon electrode with electrodeposited gold nanoparticles. Mikrochim Acta 2020; 187:567. [PMID: 32929566 DOI: 10.1007/s00604-020-04547-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 09/02/2020] [Indexed: 12/11/2022]
Abstract
A new ultrasensitive immunosensor is proposed based on the covalently attached anti-protein A antibody (IgY) on deposited gold nanoparticle (AuNP)-modified glassy carbon electrode (GCE) for the electrochemical measurement of Staphylococcus aureus (S. aureus). Chicken IgY as a capture antibody provides highly selective and specific binding to the target bacteria and selectively captures the S. aureus in its three-dimensional space. Due to that it can eliminate the interference from protein G-producing Streptococcus. In addition, the electron-transfer characteristic of [Fe(CN)6]4-/3- is hindered by this combination; as it is reflected on the electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) curves. The proposed immunosensor displays a wide linear dynamic range from 10 to 107 CFU mL-1 with a detection limit of 3.3 CFU mL-1 with RSD 3.0%. It is capable to accurately determine S. aureus in milk and human blood serum as a complex matrix sample with satisfactory recovery of ∼ 97-103%. The immunosensor also displays high selectivity over other bacteria and acceptable stability. Presumably, our study can be regarded as the first one to report chicken IgY in order to detect S. aureus based on an electrochemical method.Graphical abstract.
Collapse
|
26
|
|
27
|
Silver nanoparticle-base lateral flow immunoassay for rapid detection of Staphylococcal enterotoxin B in milk and honey. J Inorg Biochem 2020; 210:111163. [PMID: 32622212 DOI: 10.1016/j.jinorgbio.2020.111163] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 06/20/2020] [Accepted: 06/21/2020] [Indexed: 12/23/2022]
Abstract
A silver nanoparticle (AgNP)-based sandwich-type lateral flow immunoassay (LFIA) was evaluated for rapid detection of Staphylococcal enterotoxin B (SEB) in milk and honey. The role of trisodium citrate dihydrate (TSC) in the formation of Ag/TSC nanoparticles was established using UV-Vis spectroscopy. The association of silver with TSC in Ag/TSC nanoparticles was studied by the decrease in the intensity of anodic peak potential at 0.47 V and shift to 0.30 V in cyclic voltammetry (CV). The morphological, compositional and interaction studies of the AgNPs conjugated with the anti-SEB polyclonal antibody (Ag-sAb) was established using transmission electron microscopy (TEM) and X-ray photo electron spectroscopy (XPS) measurements. The visible detection limit and optical detection limit of the SEB test strip were 0.5 and 0.125 ppm, respectively, in SEB standard solution. This assay showed no cross-reaction with Staphylococcal enterotoxin A, Staphylococcal enterotoxin C or Salmonella typhi. Finally, the SEB test strip was effectively applied for the detection of SEB in spiked liquid milk and viscous honey, with optical detection limits of 0.25 and 0.5 ppm, respectively.
Collapse
|
28
|
Development of multiplex loop-mediated isothermal amplification for three foodborne pathogens. FOOD SCIENCE AND TECHNOLOGY 2020. [DOI: 10.1590/fst.07319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
29
|
A fluorescent aptasensor for Staphylococcus aureus based on strand displacement amplification and self-assembled DNA hexagonal structure. Mikrochim Acta 2020; 187:304. [PMID: 32350613 DOI: 10.1007/s00604-020-04293-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 04/22/2020] [Indexed: 12/14/2022]
Abstract
A fluorescent aptasensor for Staphylococcus aureus (S. aureus) is designed, which takes advantage of strand displacement amplification (SDA) technology and unique self-assembled DNA hexagonal structure. In the presence of S. aureus, a partially complementary strand of S. aureus aptamer (cDNA) is competitively released from cDNA/aptamer duplex immobilized on magnetic beads due to the affinity of the aptamer for S. aureus. The addition of primer starts the SDA reaction. With the catalysis of Bsm DNA polymerase and Nb.bpu10I endonuclease, a large number of single-stranded DNA (ssDNA) is produced, which induces the opening of a hairpin probe and the subsequent self-assembly to form a hexagonal structure. The staining of the DNA hexagon with SYBR Green I excites the fluorescence signal, which is used for detection. The aptasensor exhibits a broad linear range from 7 to 7 × 107 CFU/mL, with a detection limit of 1.7 CFU/mL for S. aureus. The sensor shows negligible responses to other bacteria. Moreover, the aptasensor has been applied to detect S. aureus in milk samples, and the results demonstrate the general applicability of the sensor and its prospect in systematic detection of S. aureus in food safety control and medicine-related fields. Graphical abstract The presence of S. aureus can be converted to the formation of unique DNA hexagonal structure and subsequent fluorescent signal by the combination of SDA with self-assembly technology.
Collapse
|
30
|
Rapid and sensitive detection ofStaphylococcus aureusin processed foods using a field‐deployed device to perform an insulated isothermal polymerase chain reaction‐based assay. J Food Saf 2019. [DOI: 10.1111/jfs.12690] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
31
|
|
32
|
Complementation of ELISA and an Interdigitated Electrode Surface in Gold Nanoparticle Functionalization for Effective Detection of Human Blood Clotting Defects. NANOSCALE RESEARCH LETTERS 2019; 14:222. [PMID: 31267309 PMCID: PMC6606688 DOI: 10.1186/s11671-019-3058-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Accepted: 06/20/2019] [Indexed: 05/07/2023]
Abstract
Developing an enhanced diagnosis using biosensors is important for the treatment of patients before disease complications arise. Improving biosensors would enable the detection of various low-abundance disease biomarkers. Efficient immobilization of probes/receptors on the sensing surface is one of the efficient ways to enhance detection. Herein, we introduced the pre-alkaline sensing surface with amine functionalization for capturing gold nanoparticle (GNP) conjugated to human blood clotting factor IX (FIX), and we demonstrated the excellent performance of the strategy. We have chosen the enzyme-linked immunosorbent assay (ELISA) and the interdigitated electrode (IDE), which are widely used, to demonstrate our method. The optimal amount for silanization has been found to be 2.5%, and 15-nm-sized GNPs are ideal and characterized. The limit of FIX detection was attained with ELISA at 100 pM with the premixed GNPs and FIX, which shows 60-fold improvement in sensitivity without biofouling, as compared to the conventional ELISA. Further, FIX was detected with higher specificity in human serum at a 1:1280 dilution, which is equivalent to 120 pM FIX. These results were complemented by the analysis on IDE, where improved detection at 25 pM was achieved, and FIX was detected in human serum at the dilution of 1:640. These optimized surfaces are useful for improving the detection of different diseases on varied sensing surfaces.
Collapse
|
33
|
Quantification of staphylococcal enterotoxin type A in cow milk by using a stable isotope-labelled peptide via liquid chromatography-tandem mass spectrometry. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2019; 36:1098-1108. [PMID: 31094669 DOI: 10.1080/19440049.2019.1615641] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
In this study, the staphylococcal enterotoxin type A (SEA) contaminant was quantified in cow milk by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with the use of a stable isotope-labelled peptide of SEA as an internal standard. SEA was cleaned up in a two-step process that included pH control and trichloroacetic acid (TCA) precipitation. The pH control phase eliminated other proteins. TCA precipitation cleaned up SEA without special equipment. An appropriate enzyme-to-protein ratio maximised tryptic digestion. A desalting process guaranteed the stable retention of SEA-digested peptides. The coverage of amino-acid sequences (>10%) clearly identified the toxin's presence. SEA was accurately quantified using LC-MS/MS based on a multiple-reaction monitoring mode. The developed method was validated based on spiked recovery tests at 50 and 100 µg kg-1 conducted with two samples collected on a daily basis for five days based on Japanese validation guidelines. The new method exhibited good accuracy which ranged from 80% to 82%. The relative standard deviations of repeatability were 13-14% and the relative standard deviations of within-laboratory reproducibility were 13-18%. These standard deviations satisfied the criteria of the Japanese validation guidelines. The quantification limit was estimated to be 10 µg kg-1.
Collapse
|
34
|
Functional chimera aptamer and molecular beacon based fluorescent detection of Staphylococcus aureus with strand displacement-target recycling amplification. Anal Chim Acta 2019; 1075:128-136. [PMID: 31196418 DOI: 10.1016/j.aca.2019.05.014] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 04/17/2019] [Accepted: 05/05/2019] [Indexed: 01/09/2023]
Abstract
A fluorescent detection of Staphylococcus aureus (S. aureus) is established based on a finely designed functional chimera sequence, a molecular beacon (MB), and strand displacement target recycling. The chimera sequence, which consists of the aptamer sequence of S. aureus and the complementary sequence of MB, can form a hairpin structure due to the existence of intramolecular complementary regions. When S. aureus is present, it binds to the aptamer region of the chimera, opens the hairpin and unlocks the complementary sequence of MB. Subsequently, the MB is opened and intensive fluorescence signal is restored. To increase the sensitivity of the detection, signal amplification is achieved through strand displacement-based target recycling. With the catalysis of Nb. Bpu10I nicking endonuclease and Bsm DNA polymerase, the MB sequence can be cleaved and then elongated to form a complete duplex with the chimera, during which S. aureus is displaced from the chimera and proceeded to the next round of the reaction. This assay displays a linear correlation between the fluorescence intensity and the logarithm of the concentration of S. aureus within a broad concentration range from 80 CFU/mL to 8 × 106 CFU/mL. The detection limit of 39 CFU/mL can be derived. The assay was applied to detect S. aureus in different water samples, and satisfactory recovery and repeatability were achieved. Hence the designed chimera sequence and established assay have potential application in environmental pollution monitoring.
Collapse
|