1
|
Lee SY, Kim U, Kim Y, Lee SJ, Park EY, Oh SW. Enhanced detection of Listeria monocytogenes using tetraethylenepentamine-functionalized magnetic nanoparticles and LAMP-CRISPR/Cas12a-based biosensor. Anal Chim Acta 2023; 1281:341905. [PMID: 38783743 DOI: 10.1016/j.aca.2023.341905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 10/06/2023] [Accepted: 10/10/2023] [Indexed: 05/25/2024]
Abstract
BACKGROUND Listeria monocytogenes is a pathogenic bacterium that can lead to severe illnesses, especially among vulnerable populations. Therefore, the development of rapid and sensitive detection methods is vital to prevent and manage foodborne diseases. In this study, we used tetraethylenepentamine (TEPA)-functionalized magnetic nanoparticles (MNPs) and a loop-mediated isothermal amplification (LAMP)-based CRISPR/Cas12a-based biosensor to concentrate and detect, respectively, L. monocytogenes. LAMP enables DNA amplification at a constant temperature, providing a highly suitable approach for point-of-care testing (POCT). The ability of CRISPR/Cas12a to cleave ssDNA reporter, coupled with TEPA-functionalized MNPs effective attachment to negatively charged bacteria, forms a promising biosensor. RESULTS The LAMP assay was meticulously developed by selecting specific primers and designing crRNA sequences targeting a specific region within the hly gene of L. monocytogenes. We selected primer and refined the amplification conditions by systematically exploring a temperature range from 59 °C to 69 °C, ensuring the attainment of optimal performance. This process was complemented by systematic optimization of LAMP-CRISPR/Cas12a system parameters. In particular, we successfully established the optimal ssDNA reporter concentrations (0-1.2 μM) and Cas12a-mediated trans-cleavage times (0-20 min), crucial components that underpin the effectiveness of the LAMP-CRISPR/Cas12a-based biosensor. For optimizing parameters in capturing L. monocytogenes using TEPA-functionalized MNPs, capture efficiency was significantly enhanced through adjustments in TEPA-functionalized MNPs concentration, incubation times, and magnetic separation duration. Large-volume (20 mL) magnetic separation exhibited a 10-fold sensitivity improvement over conventional methods. Utilizing TEPA-functionalized MNPs, the LAMP-CRISPR/Cas12a-based biosensor achieved detection limits of 100 CFU mL-1 in pure cultures and 100 CFU g-1 in enoki mushrooms. SIGNIFICANCE The integration of this novel technique with the LAMP-CRISPR/Cas12a-based biosensor enhances the accuracy and sensitivity of L. monocytogenes detection in foods, and it can be a promising biosensor for POCT. The 10-fold increase in sensitivity compared to conventional methods makes this approach a groundbreaking advancement in pathogenic bacteria detection for food safety and public health.
Collapse
Affiliation(s)
- So-Young Lee
- Department of Food and Nutrition, Kookmin University, Seoul, 136-702, Republic of Korea
| | - Unji Kim
- Department of Food and Nutrition, Kookmin University, Seoul, 136-702, Republic of Korea
| | - Younggyu Kim
- Lumimac, Inc, B1, 4, Dongnam-ro 2 gil, Songpa-gu, Seoul, Republic of Korea
| | - Seung Jae Lee
- Lumimac, Inc, B1, 4, Dongnam-ro 2 gil, Songpa-gu, Seoul, Republic of Korea
| | - Eun Young Park
- Lumimac, Inc, B1, 4, Dongnam-ro 2 gil, Songpa-gu, Seoul, Republic of Korea
| | - Se-Wook Oh
- Department of Food and Nutrition, Kookmin University, Seoul, 136-702, Republic of Korea.
| |
Collapse
|
2
|
Lee SY, Kim JH, Oh SW. Combination of filtration and immunomagnetic separation based on real-time PCR to detect foodborne pathogens in fresh-cut apple. J Microbiol Methods 2022; 201:106577. [PMID: 36103904 DOI: 10.1016/j.mimet.2022.106577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 08/23/2022] [Accepted: 09/06/2022] [Indexed: 12/27/2022]
Abstract
Rapid detection methods require pre-enrichment culture in order to detect low levels of foodborne pathogens. To rapidly detect foodborne pathogens, enrichment culture processes could be replaced. Filtration and immunomagnetic separation methods have been identified to effectively concentrate and separate target pathogens from foods. In this study, a combination of filtration and immunomagnetic separation (IMS) has enabled the rapid and sensitive detection of foodborne pathogens. The pretreatment method, including separation and concentration procedures, increased sensitivity 10-100-fold. The sensitivity of a combination method using filtration and IMS to detect Escherichia coli O157:H7 and Salmonella enterica subsp. enterica serovar Typhimurium was 100-101 CFU/10 mL. In fresh-cut apples, IMS combined with filtration effectively improved the detection limit of real-time PCR to 2.70 × 101 CFU/g in E. coli O157:H7 and 1.80 × 102 CFU/g in Salmonella. The filtration simplified processing of large-volumes (250 mL) and effectively concentrated pathogens while decreasing immunomagnetic beads used in IMS. Bacterial concentration by IMS combined with filtration increased sensitivity 10-100-fold compared with control. In addition, the application of IMS effectively removed concentrated residual food material (10-15 mg/mL) after filtration, improving relative sensitivity. In conclusion, this method may detect foodborne pathogen in foods such as fresh-cut fruits in a more rapid and sensitive fashion than traditional culture-based methods.
Collapse
Affiliation(s)
- So-Young Lee
- Department of Food and Nutrition, Kookmin University, Seoul 136-702, Republic of Korea
| | - Jin-Hee Kim
- Department of Food and Nutrition, Mokpo National University, Jeonnam, Republic of Korea; Research Institute of Human Ecology, Mokpo National University, Jeonnam, Republic of Korea
| | - Se-Wook Oh
- Department of Food and Nutrition, Kookmin University, Seoul 136-702, Republic of Korea.
| |
Collapse
|
3
|
Trends in the bacterial recognition patterns used in surface enhanced Raman spectroscopy. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116310] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
4
|
Ajish JK, Abraham HM, Subramanian M, Kumar KSA. A Reusable Column Method Using Glycopolymer-Functionalized Resins for Capture-Detection of Proteins and Escherichia coli. Macromol Biosci 2020; 21:e2000342. [PMID: 33336880 DOI: 10.1002/mabi.202000342] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 11/27/2020] [Indexed: 11/08/2022]
Abstract
The use of glycopolymer-functionalized resins (Resin-Glc), as a solid support, in column mode for bacterial/protein capture and quantification is explored. The Resin-Glc is synthesized from commercially available chloromethylated polystyrene resin and glycopolymer, and is characterized by fourier transform infrared spectroscopy, thermogravimetry, and elemental analysis. The percentage of glycopolymer functionalized on Resin-Glc is accounted to be 5 wt%. The ability of Resin-Glc to selectively capture lectin, Concanavalin A, over Peanut Agglutinin, reversibly, is demonstrated for six cycles of experiments. The bacterial sequestration study using SYBR (Synergy Brands, Inc.) Green I tagged Escherichia coli/Staphylococcus aureus reveals the ability of Resin-Glc to selectively capture E. coli over S. aureus. The quantification of captured cells in the column is carried out by enzymatic colorimetric assay using methylumbelliferyl glucuronide as the substrate. The E. coli capture studies reveal a consistent capture efficiency of 105 CFU (Colony Forming Units) g-1 over six cycles. Studies with spiked tap water samples show satisfactory results for E. coli cell densities ranging from 102 to 107 CFU mL-1 . The method portrayed can serve as a basis for the development of a reusable solid support in capture and detection of proteins and bacteria.
Collapse
Affiliation(s)
- Juby K Ajish
- Radiation and Photochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
| | - Hephziba Maria Abraham
- Department of Polymer Science and Rubber Technology, Cochin University of Science and Technology, Kochi, 682020, India
| | - Mahesh Subramanian
- Bio-Organic Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
| | - K S Ajish Kumar
- Bio-Organic Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
| |
Collapse
|
5
|
Detection of Escherichia coli O157:H7 Using Automated Immunomagnetic Separation and Enzyme-Based Colorimetric Assay. SENSORS 2020; 20:s20051395. [PMID: 32143335 PMCID: PMC7085514 DOI: 10.3390/s20051395] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 03/02/2020] [Accepted: 03/03/2020] [Indexed: 12/20/2022]
Abstract
The food industry requires rapid and simple detection methods for preventing harm from pathogenic bacteria. Until now, various technologies used to detect foodborne bacteria were time-consuming and laborious. Therefore, we have developed an automated immunomagnetic separation combined with a colorimetric assay for the rapid detection of E. coli O157:H7 in food samples. The colorimetric detection method using enzymatic reaction is fascinating because of its simplicity and rapidity and does not need sophisticated devices. Moreover, the proposed procedures for the detection of bacteria in food take less than 3 h including pre-enrichment, separation and detection steps. First, target-specific immunomagnetic beads were introduced to contaminated milk in a pre-enrichment step. Second, the pre-enriched sample solution containing target bacteria bound on immunomagnetic beads was injected into an automated pretreatment system. Subsequently, the immunomagnetic beads along with target bacteria were separated and concentrated into a recovery tube. Finally, released β-galactosidase from E. coli O157:H7 after lysis was reacted with chlorophenol red β-galactopyranoside (CPRG) used as a substrate and the colorimetric change of CPRG was determined by absorbance measuring or the naked eye. By the proposed approach in this study, we could detect 3 × 102 CFU/mL of E. coli O157:H7 from a milk sample within 3 h.
Collapse
|
6
|
Guo R, Huang F, Cai G, Zheng L, Xue L, Li Y, Liao M, Wang M, Lin J. A colorimetric immunosensor for determination of foodborne bacteria using rotating immunomagnetic separation, gold nanorod indication, and click chemistry amplification. Mikrochim Acta 2020; 187:197. [PMID: 32125533 DOI: 10.1007/s00604-020-4169-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Accepted: 02/13/2020] [Indexed: 11/24/2022]
Abstract
A colorimetric immunosensor was developed for the determination of Salmonella Typhimurium using rotating magnetic separation, gold nanorod (GNR) indication, and click chemistry amplification. The target bacteria were first separated from large-volume sample using a rotating magnetic field and a small amount (50 μg) of immunomagnetic nanoparticles (MNPs), resulting in the forming of magnetic bacteria. Then, the magnetic bacteria were conjugated with catalase (CAT)-labeled antibodies, which were synthesized using trans-cyclooctene/1,2,4,5-tetrazine click chemistry reaction, resulting in the forming of enzymatic bacteria. Then the CATs on the enzymatic bacteria were used to decompose an excessive amount of hydrogen peroxide (H2O2), the remaining H2O2 was mixed with horseradish peroxidase to etch the GNRs, resulting in color change and absorbance peak shift of the GNRs. Finally, the peak shift was measured and analyzed for the quantitative determination of target bacteria. This immunosensor was able to detect Salmonella Typhimurium with a linear range of 101-105 CFU mL-1 in 3 h with a low detection limit of 35 CFU mL-1. The mean recovery for Salmonella Typhimurium in spiked chicken samples was 109%. Graphical abstractSchematic representation of a colorimetric immunosensor for the determination of Salmonella Typhimurium as low as 35 CFU mL-1 using rotating magnetic separation of Salmonella from a large-volume sample, click chemistry reaction of catalase with antibodies for signal amplification, and HRP-mediated gold nanorod etching for result indication.
Collapse
Affiliation(s)
- Ruya Guo
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing, 100083, China
| | - Fengchun Huang
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing, 100083, China
| | - Gaozhe Cai
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing, 100083, China
| | - Lingyan Zheng
- Key Laboratory of Modern Precision Agriculture System Integration Research, Ministry of Education, China Agricultural University, Beijing, 100083, China
| | - Li Xue
- Key Laboratory of Modern Precision Agriculture System Integration Research, Ministry of Education, China Agricultural University, Beijing, 100083, China
| | - Yanbin Li
- Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR, 72701, USA
| | - Ming Liao
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, 510642, China
| | - Maohua Wang
- Key Laboratory of Modern Precision Agriculture System Integration Research, Ministry of Education, China Agricultural University, Beijing, 100083, China
| | - Jianhan Lin
- Key Laboratory of Modern Precision Agriculture System Integration Research, Ministry of Education, China Agricultural University, Beijing, 100083, China.
| |
Collapse
|
7
|
Lee WI, Park Y, Shrivastava S, Jung T, Meeseepong M, Lee J, Jeon B, Yang S, Lee NE. A fully integrated bacterial pathogen detection system based on count-on-a-cartridge platform for rapid, ultrasensitive, highly accurate and culture-free assay. Biosens Bioelectron 2020; 152:112007. [DOI: 10.1016/j.bios.2020.112007] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 01/02/2020] [Accepted: 01/04/2020] [Indexed: 12/13/2022]
|
8
|
Kim Y, Abafogi AT, Tran BM, Kim J, Lee J, Chen Z, Bae PK, Park K, Shin YB, van Noort D, Lee NY, Park S. Integrated Microfluidic Preconcentration and Nucleic Amplification System for Detection of Influenza A Virus H1N1 in Saliva. MICROMACHINES 2020; 11:E203. [PMID: 32079062 PMCID: PMC7074655 DOI: 10.3390/mi11020203] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2020] [Revised: 02/10/2020] [Accepted: 02/13/2020] [Indexed: 12/27/2022]
Abstract
Influenza A viruses are often present in environmental and clinical samples at concentrations below the limit of detection (LOD) of molecular diagnostics. Here we report an integrated microfluidic preconcentration and nucleic amplification system (μFPNAS) which enables both preconcentration of influenza A virus H1N1 (H1N1) and amplification of its viral RNA, thereby lowering LOD for H1N1. H1N1 virus particles were first magnetically preconcentrated using magnetic nanoparticles conjugated with an antibody specific for the virus. Their isolated RNA was amplified to cDNA through thermocycling in a trapezoidal chamber of the μFPNAS. A detection limit as low as 100 TCID50 (50% tissue culture infective dose) in saliva can be obtained within 2 hours. These results suggest that the LOD of molecular diagnostics for virus can be lowered by systematically combining immunomagnetic separation and reverse transcriptase-polymerase chain reaction (RT-PCR) in one microfluidic device.
Collapse
Affiliation(s)
- Yonghee Kim
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (Y.K.); (A.T.A.); (J.K.); (J.L.); (Z.C.)
| | - Abdurhaman Teyib Abafogi
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (Y.K.); (A.T.A.); (J.K.); (J.L.); (Z.C.)
| | - Buu Minh Tran
- Department of BioNano Technology, College of BioNano Technology, Gachon University, Seongnam 13120, Korea; (B.M.T.); (N.Y.L.)
| | - Jaewon Kim
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (Y.K.); (A.T.A.); (J.K.); (J.L.); (Z.C.)
| | - Jinyeop Lee
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (Y.K.); (A.T.A.); (J.K.); (J.L.); (Z.C.)
| | - Zhenzhong Chen
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (Y.K.); (A.T.A.); (J.K.); (J.L.); (Z.C.)
| | - Pan Kee Bae
- BioNano Health Guard Research Center (H-GUARD), Daejeon 34141, Korea; (P.K.B.); (K.P.); (Y.-B.S.)
| | - Kyoungsook Park
- BioNano Health Guard Research Center (H-GUARD), Daejeon 34141, Korea; (P.K.B.); (K.P.); (Y.-B.S.)
| | - Yong-Beom Shin
- BioNano Health Guard Research Center (H-GUARD), Daejeon 34141, Korea; (P.K.B.); (K.P.); (Y.-B.S.)
- Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, Korea
- Department of bioengineering, KRIBB School, University of science and Technology (UST), Daejeon 34141, Korea
| | - Danny van Noort
- Department of Physics, Chemistry and Biology, Linköping University, 581 83 Linköping, Sweden
- Chair of Micro Process Engineering and Technology (COMPETE), University of Ljubljana, 1000 Ljubljana, Slovenia
- Centro de Investigación en Bioingeniería -BIO, Universidad de Ingenieria y Tecnologia—UTEC, Barranco 15036, Peru
| | - Nae Yoon Lee
- Department of BioNano Technology, College of BioNano Technology, Gachon University, Seongnam 13120, Korea; (B.M.T.); (N.Y.L.)
| | - Sungsu Park
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (Y.K.); (A.T.A.); (J.K.); (J.L.); (Z.C.)
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon 16419, Korea
| |
Collapse
|
9
|
MERCANOGLU TABAN B, AYTAC SA. An evaluation of immunomagnetic separation-real-time PCR (IMS-RTiPCR) combined assay for rapid and specific detection of Escherichia coli O157:H7 in raw milk and ground beef. FOOD SCIENCE AND TECHNOLOGY 2019. [DOI: 10.1590/fst.15818] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
10
|
Quintela IA, de Los Reyes BG, Lin CS, Wu VCH. Simultaneous Colorimetric Detection of a Variety of Salmonella spp. in Food and Environmental Samples by Optical Biosensing Using Oligonucleotide-Gold Nanoparticles. Front Microbiol 2019; 10:1138. [PMID: 31214132 PMCID: PMC6554661 DOI: 10.3389/fmicb.2019.01138] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 05/06/2019] [Indexed: 01/17/2023] Open
Abstract
Optical biosensors for rapid detection of significant foodborne pathogens are steadily gaining popularity due to its simplicity and sensitivity. While nanomaterials such as gold nanoparticles (AuNPs) are commonly used as signal amplifiers for optical biosensors, AuNPs can also be utilized as a robust biosensing platform. Many reported optical biosensors were designed for individual pathogen detection in a single assay and have high detection limit (DL). Salmonella spp. is one of the major causative agents of foodborne sickness, hospitalization and deaths. Unfortunately, there are around 2,000 serotypes of Salmonella worldwide, and rapid and simultaneous detection of multiple strains in a single assay is lacking. In this study, a comprehensive and highly sensitive simultaneous colorimetric detection of nineteen (19) environmental and outbreak Salmonella spp. strains was achieved by a novel optical biosensing platform using oligonucleotide-functionalized AuNPs. A pair of newly designed single stranded oligonucleotides (30-mer) was displayed onto the surface of AuNPs (13 nm) as detection probes to hybridize with a conserved genomic region (192-bases) of ttrRSBCA found on a broad range of Salmonella spp. strains. The sandwich hybridization (30 min, 55°C) resulted in a structural formation of highly stable oligonucleotide/AuNPs-DNA complexes which remained undisturbed even after subjecting to an increased salt concentration (2 M, final), thus allowing a direct discrimination via color change of target (red color) from non-target (purplish-blue color) reaction mixtures by direct observation using the naked eye. In food matrices (blueberries and chicken meat), nineteen different Salmonella spp. strains were concentrated using immunomagnetic separation and then simultaneously detected in a 96-well microplate by oligonucleotide-functionalized AuNPs after DNA preparation. Successful oligonucleotide/AuNPs-DNA hybridization was confirmed by gel electrophoresis while AuNPs aggregation in non-target and control reaction mixtures was verified by both spectrophotometric analysis and TEM images. Results showed that the optical AuNP biosensing platform can simultaneously screen nineteen (19) viable Salmonella spp. strains tested with 100% specificity and a superior detection limit of <10 CFU/mL or g for both pure culture and complex matrices setups. The highly sensitive colorimetric detection system can significantly improve the screening and detection of viable Salmonella spp. strains present in complex food and environmental matrices, therefore reducing the risks of contamination and incidence of foodborne diseases.
Collapse
Affiliation(s)
- Irwin A Quintela
- Produce Safety and Microbiology Research Unit, U.S. Department of Agriculture, Agricultural Research Services, Western Regional Research Center, Albany, CA, United States.,School of Food and Agriculture, University of Maine, Orono, ME, United States
| | | | - Chih-Sheng Lin
- Department of Biological Science and Technology, National Chiao Tung University, Hsinchu, Taiwan
| | - Vivian C H Wu
- Produce Safety and Microbiology Research Unit, U.S. Department of Agriculture, Agricultural Research Services, Western Regional Research Center, Albany, CA, United States.,Department of Plant and Soil Science, Texas Tech University, Lubbock, TX, United States
| |
Collapse
|
11
|
Development of a low-cost paper-based ELISA method for rapid Escherichia coli O157:H7 detection. Anal Biochem 2018; 542:58-62. [DOI: 10.1016/j.ab.2017.11.010] [Citation(s) in RCA: 99] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2017] [Revised: 09/29/2017] [Accepted: 11/15/2017] [Indexed: 02/07/2023]
|
12
|
Chen J, Park B. Effect of immunomagnetic bead size on recovery of foodborne pathogenic bacteria. Int J Food Microbiol 2018; 267:1-8. [DOI: 10.1016/j.ijfoodmicro.2017.11.022] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 10/06/2017] [Accepted: 11/25/2017] [Indexed: 11/28/2022]
|
13
|
Luo D, Huang X, Mao Y, Chen C, Li F, Xu H, Xiong Y. Two-step large-volume magnetic separation combined with PCR assay for sensitive detection of Listeria monocytogenes in pasteurized milk. J Dairy Sci 2017; 100:7883-7890. [DOI: 10.3168/jds.2017-13140] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Accepted: 06/17/2017] [Indexed: 11/19/2022]
|
14
|
Ganesh I, Tran BM, Kim Y, Kim J, Cheng H, Lee NY, Park S. An integrated microfluidic PCR system with immunomagnetic nanoparticles for the detection of bacterial pathogens. Biomed Microdevices 2017; 18:116. [PMID: 27975186 DOI: 10.1007/s10544-016-0139-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
There is growing interest in rapid microbial pre-concentration methods to lower the detection limit of bacterial pathogens of low abundance in samples. Here, we report an integrated microfluidic PCR system that enables bacterial cells of interest in samples to be concentrated prior to PCR. It consists of two major compartments: a preconcentration chamber for the immunomagnetic separation of bacterial cells, and a PCR chamber for the DNA amplification of the concentrated cells. We demonstrate the feasibility of the system for the detection of microbial pathogens by preconcentrating the human pathogen Escherichia coli O157:H7, and also amplifying its DNA. The detection limit of E. coli O157:H7 in the PCR system is 1 × 103 CFU (colony forming unit)/mL. On-chip processing steps, including preconcentration and PCR steps, take less than two hours. Our system can serve as a rapid, specific, and quantitative platform for the detection of microbial pathogens in samples of large volume.
Collapse
Affiliation(s)
- Irisappan Ganesh
- School of Mechanical Engineering, Sungkyunkwan University, Suwon, 16419, Korea
| | - Buu Minh Tran
- Department of BioNano Technology, College of BioNano Technology, Gachon University, Seongnam, Gyeonggi-do, 13120, Korea
| | - Yonghee Kim
- School of Mechanical Engineering, Sungkyunkwan University, Suwon, 16419, Korea
| | - Jaewon Kim
- School of Mechanical Engineering, Sungkyunkwan University, Suwon, 16419, Korea
| | - Hua Cheng
- Department of Chemistry and Nano Sciences (BK21 plus), Ewha Womans University, Seoul, 03760, Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, College of BioNano Technology, Gachon University, Seongnam, Gyeonggi-do, 13120, Korea.
| | - Sungsu Park
- School of Mechanical Engineering, Sungkyunkwan University, Suwon, 16419, Korea.
| |
Collapse
|
15
|
An automated system for separation and concentration of food-borne pathogens using immunomagnetic separation. Food Control 2017. [DOI: 10.1016/j.foodcont.2016.11.021] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
16
|
Bai Y, Cui Y, Paoli GC, Shi C, Wang D, Zhou M, Zhang L, Shi X. Synthesis of amino-rich silica-coated magnetic nanoparticles for the efficient capture of DNA for PCR. Colloids Surf B Biointerfaces 2016; 145:257-266. [PMID: 27187190 DOI: 10.1016/j.colsurfb.2016.05.003] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Revised: 04/23/2016] [Accepted: 05/02/2016] [Indexed: 11/26/2022]
Abstract
Magnetic separation has great advantages over traditional bio-separation methods and has become popular in the development of methods for the detection of bacterial pathogens, viruses, and transgenic crops. Functionalization of magnetic nanoparticles is a key factor for efficient capture of the target analytes. In this paper, we report the synthesis of amino-rich silica-coated magnetic nanoparticles using a one-pot method. This type of magnetic nanoparticle has a rough surface and a higher density of amino groups than the nanoparticles prepared by a post-modification method. Furthermore, the results of hydrochloric acid treatment indicated that the magnetic nanoparticles were stably coated. The developed amino-rich silica-coated magnetic nanoparticles were used to directly adsorb DNA. After magnetic separation and blocking, the magnetic nanoparticles and DNA complexes were used directly for the polymerase chain reaction (PCR), without onerous and time-consuming purification and elution steps. The results of real-time quantitative PCR showed that the nanoparticles with higher amino group density resulted in improved DNA capture efficiency. The results suggest that amino-rich silica-coated magnetic nanoparticles are of great potential for efficient bio-separation of DNA prior to detection by PCR.
Collapse
Affiliation(s)
- Yalong Bai
- MOST-USDA Joint Research Center for Food Safety & Bor Luh Food Safety Center, School of Agriculture and Biology & State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Yan Cui
- MOST-USDA Joint Research Center for Food Safety & Bor Luh Food Safety Center, School of Agriculture and Biology & State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - George C Paoli
- USDA-MOST Joint Research Center for Food Safety & Molecular Characterization of Foodborne Pathogens Research Unit, U.S. Department of Agriculture, Agricultural Research Service, Eastern Regional Research Center, Wyndmoor, PA 19038, USA
| | - Chunlei Shi
- MOST-USDA Joint Research Center for Food Safety & Bor Luh Food Safety Center, School of Agriculture and Biology & State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Dapeng Wang
- MOST-USDA Joint Research Center for Food Safety & Bor Luh Food Safety Center, School of Agriculture and Biology & State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Min Zhou
- MOST-USDA Joint Research Center for Food Safety & Bor Luh Food Safety Center, School of Agriculture and Biology & State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai 200240, PR China; School of Food Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, PR China
| | - Lida Zhang
- MOST-USDA Joint Research Center for Food Safety & Bor Luh Food Safety Center, School of Agriculture and Biology & State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Xianming Shi
- MOST-USDA Joint Research Center for Food Safety & Bor Luh Food Safety Center, School of Agriculture and Biology & State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai 200240, PR China.
| |
Collapse
|
17
|
Blagden T, Schneider W, Melcher U, Daniels J, Fletcher J. Adaptation and Validation of E-Probe Diagnostic Nucleic Acid Analysis for Detection of Escherichia coli O157:H7 in Metagenomic Data from Complex Food Matrices. J Food Prot 2016; 79:574-81. [PMID: 27052861 DOI: 10.4315/0362-028x.jfp-15-440] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The Centers for Disease Control and Prevention recently emphasized the need for enhanced technologies to use in investigations of outbreaks of foodborne illnesses. To address this need, e-probe diagnostic nucleic acid analysis (EDNA) was adapted and validated as a tool for the rapid, effective identification and characterization of multiple pathogens in a food matrix. In EDNA, unassembled next generation sequencing data sets from food sample metagenomes are queried using pathogen-specific sequences known as electronic probes (e-probes). In this study, the query of mock sequence databases demonstrated the potential of EDNA for the detection of foodborne pathogens. The method was then validated using next generation sequencing data sets created by sequencing the metagenome of alfalfa sprouts inoculated with Escherichia coli O157:H7. Nonspecific hits in the negative control sample indicated the need for additional filtration of the e-probes to enhance specificity. There was no significant difference in the ability of an e-probe to detect the target pathogen based upon the length of the probe set oligonucleotides. The results from the queries of the sample database using E. coli e-probe sets were significantly different from those obtained using random decoy probe sets and exhibited 100% precision. The results support the use of EDNA as a rapid response methodology in foodborne outbreaks and investigations for establishing comprehensive microbial profiles of complex food samples.
Collapse
Affiliation(s)
- Trenna Blagden
- Department of Entomology and Plant Pathology, 127 NRC, Oklahoma State University, Stillwater, Oklahoma 74078, USA.
| | - William Schneider
- U.S. Department of Agriculture, Agricultural Research Service, Room 139, Building 1301, 1301 Ditto Avenue, Fort Detrick, Maryland 21702, USA
| | - Ulrich Melcher
- Department of Biochemistry and Molecular Biology, 246 NRC, Oklahoma State University, Stillwater, Oklahoma 74078, USA
| | - Jon Daniels
- Department of Entomology and Plant Pathology, 127 NRC, Oklahoma State University, Stillwater, Oklahoma 74078, USA
| | - Jacqueline Fletcher
- Department of Entomology and Plant Pathology, 127 NRC, Oklahoma State University, Stillwater, Oklahoma 74078, USA
| |
Collapse
|
18
|
Wang H, Gill VS, Cheng CM, Gonzalez-Escalona N, Irvin KA, Zheng J, Bell RL, Jacobson AP, Hammack TS. Evaluation and comparison of rapid methods for the detection of Salmonella in naturally contaminated pine nuts using different pre enrichment media. Food Microbiol 2015; 46:58-65. [DOI: 10.1016/j.fm.2014.06.028] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2013] [Revised: 06/18/2014] [Accepted: 06/20/2014] [Indexed: 11/30/2022]
|