1
|
Westlund Gotby LEL, Stella M, Van Speybroeck CDE, Lobeek D, van Velden FHP, Stam MK, Dibbets-Schneider P, de Vries-Huizing DMV, Rijkhorst EJ, de Wit-van de Veen BJ, Wierts R, van Rooij R. Towards harmonized holmium-166 SPECT image quality for dosimetry: a multi-center, multi-vendor study. EJNMMI Phys 2025; 12:24. [PMID: 40102311 PMCID: PMC11920561 DOI: 10.1186/s40658-025-00733-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Accepted: 02/17/2025] [Indexed: 03/20/2025] Open
Abstract
BACKGROUND Reliable dosimetry based on SPECT/CT imaging is essential to achieve personalized 166Ho-radioembolization treatment planning and evaluation. This study quantitatively evaluates multiple acquisition and reconstruction protocols for 166Ho-SPECT imaging based on data from five Dutch hospitals. We aim to recommend an imaging protocol which harmonizes 166Ho-SPECT images for reproducible and accurate dosimetry in a multi-scanner and multi-center setting. METHODS Cylindrical and NEMA IEC phantoms, filled with 166Ho-chloride, were imaged using seven SPECT/CT scanners from two vendors (GE HealthCare and Siemens Healthineers). Data were acquired with a photopeak window centered at 81 keV. Two adjacent scatter windows, and one upper scatter window at 118 keV were used for triple-energy window (TEW) and dual-energy window (DEW) scatter correction, respectively. The TEW and DEW reconstructions used vendor-specific software. Additionally, a vendor-neutral software package with Monte Carlo (MC) scatter correction (Hermes Medical Solutions) was used to study the influence of scanner hardware on the image quality. System sensitivity was measured in projection data of the cylindrical phantom. The axial uniformity in the cylindrical phantom was used to characterize the impact of the scatter correction method. The image quality was evaluated by the coefficient of variation (COV; noise), the contrast recovery coefficients (CRCs) and contrast-to-noise ratios (CNRs). RESULTS TEW scatter correction resulted in superior uniformity and higher CRCs compared to the DEW (CRC for the largest sphere over all scanners, mean ± SD (range): TEW 0.54 ± 0.07 (0.36-0.65), DEW 0.44 ± 0.04 (0.34-0.51)). DEW resulted in lower noise levels compared to TEW (16% lower on average). The DEW and TEW images resulted in comparable CNRs. The system sensitivities and the vendor-neutral image reconstructions demonstrated differences in hardware between the two vendors, most likely due to the characteristics of the vendor-specific medium energy collimator. CONCLUSION This study demonstrates that TEW scatter correction increases the accuracy of 166Ho-SPECT images compared to DEW, and we henceforth recommend adopting this method in the clinical 166Ho-dosimetry workflow. Scanner hardware has a substantial impact on the characteristics of the acquired data, and identical reconstruction settings will therefore not automatically lead to harmonized image quality.
Collapse
Affiliation(s)
- Lovisa E L Westlund Gotby
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.
| | - Martina Stella
- Department of Radiology and Nuclear Medicine, University Medical Centre Utrecht, Heidelberglaan 100, 3584CX, Utrecht, The Netherlands
| | - Camille D E Van Speybroeck
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| | - Daphne Lobeek
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| | - Floris H P van Velden
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Mette K Stam
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Petra Dibbets-Schneider
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Daphne M V de Vries-Huizing
- Department of Nuclear Medicine, Netherlands Cancer Institute, Plesmanlaan 121, 1066CX, Amsterdam, The Netherlands
| | - Erik-Jan Rijkhorst
- Department of Nuclear Medicine, Netherlands Cancer Institute, Plesmanlaan 121, 1066CX, Amsterdam, The Netherlands
| | | | - Roel Wierts
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, P. Debyelaan 25, 6299 HX, Maastricht, The Netherlands
| | - Rob van Rooij
- Department of Radiology and Nuclear Medicine, University Medical Centre Utrecht, Heidelberglaan 100, 3584CX, Utrecht, The Netherlands
| |
Collapse
|
2
|
van Wijk MWM, van Wolfswinkel G, Arntz MJ, Janssen MJR, Roosen J, Nijsen JFW. Development and validation of an innovative administration system to facilitate controlled holmium-166 microsphere administration during TARE. EJNMMI Phys 2024; 11:87. [PMID: 39412619 PMCID: PMC11484995 DOI: 10.1186/s40658-024-00692-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Accepted: 10/10/2024] [Indexed: 10/19/2024] Open
Abstract
BACKGROUND To develop and validate a novel administration device for holmium-166 transarterial radioembolisation (TARE) with the purpose of facilitating controlled fractional microsphere administration for a more flexible and image-guided TARE procedure. METHODS A Controlled Administration Device (CAD) was developed using MR-conditional materials. The CAD contains a rotating syringe to keep the microspheres in suspension during administration. Different rotational speeds were tested ex vivo to optimise the homogeneity of microsphere fractions administered from the device. The technical performance, accuracy, and safety was validated in three patients in a clinical TARE setting by administering a standard clinical dose in 5 fractions (identifier: NCT05183776). MRI-based dosimetry was used to validate the homogeneity of the given fractions in vivo, and serious adverse device event ((S)A(D)E) reporting was performed to assess safety of the CAD. RESULTS A rotational speed of 30 rpm resulted in the most homogeneous microsphere fractions with a relative mean deviation of 1.1% (range: -9.1-8.0%). The first and last fraction showed the largest deviation with a mean of -26% (std. 16%) and 7% (std. 13%). respectively. In the three patient cases the homogeneity of the microsphere fractions was confirmed given that MRI-based dosimetry showed near linear increase of mean absorbed target liver dose over the given fractions with R2 values of 0.98, 0.97 and 0.99. No (S)A(D)E's could be contributed to the use of the CAD. CONCLUSIONS The newly developed CAD facilitates safe and accurate fractional microsphere administration during TARE, and can be used for multiple applications in the current and future workflows of TARE.
Collapse
Affiliation(s)
- Meike W M van Wijk
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
| | | | - Mark J Arntz
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Marcel J R Janssen
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Joey Roosen
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - J Frank W Nijsen
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
3
|
Morsink C, Klaassen N, van de Maat G, Boswinkel M, Arranja A, Bruggink R, van Houwelingen I, Schaafsma I, Hesselink JW, Nijsen F, van Nimwegen B. Quantitative CT imaging and radiation-absorbed dose estimations of 166Ho microspheres: paving the way for clinical application. Eur Radiol Exp 2024; 8:116. [PMID: 39400769 PMCID: PMC11473764 DOI: 10.1186/s41747-024-00511-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2024] [Accepted: 09/05/2024] [Indexed: 10/15/2024] Open
Abstract
BACKGROUND Microbrachytherapy enables high local tumor doses sparing surrounding tissues by intratumoral injection of radioactive holmium-166 microspheres (166Ho-MS). Magnetic resonance imaging (MRI) cannot properly detect high local Ho-MS concentrations and single-photon emission computed tomography has insufficient resolution. Computed tomography (CT) is quicker and cheaper with high resolution and previously enabled Ho quantification. We aimed to optimize Ho quantification on CT and to implement corresponding dosimetry. METHODS Two scanners were calibrated for Ho detection using phantoms and multiple settings. Quantification was evaluated in five phantoms and seven canine patients using subtraction and thresholding including influences of the target tissue, injected amounts, acquisition parameters, and quantification volumes. Radiation-absorbed dose estimation was implemented using a three-dimensional 166Ho specific dose point kernel generated with Monte Carlo simulations. RESULTS CT calibration showed a near-perfect linear relation between radiodensity (HU) and Ho concentrations for all conditions, with differences between scanners. Ho detection during calibration was higher using lower tube voltages, soft-tissue kernels, and without a scanner detection limit. The most accurate Ho recovery in phantoms was 102 ± 11% using a threshold of mean tissue HU + (2 × standard deviation) and in patients 98 ± 31% using a 100 HU threshold. Thresholding allowed better recovery with less variation and dependency on the volume of interest compared to the subtraction of a single HU reference value. Corresponding doses and histograms were successfully generated. CONCLUSION CT quantification and dosimetry of 166Ho should be considered for further clinical application with on-site validation using radioactive measurements and intra-operative Ho-MS and dose visualizations. RELEVANCE STATEMENT Image-guided holmium-166 microbrachytherapy currently lacks reliable quantification and dosimetry on CT to ensure treatment safety and efficacy, while it is the only imaging modality capable of quantifying high in vivo holmium concentrations. KEY POINTS Local injection of 166Ho-MS enables high local tumor doses while sparing surrounding tissue. CT enables imaging-based quantification and radiation-absorbed dose estimation of concentrated Ho in vivo, essential for treatment safety and efficacy. Two different CT scanners and multiple acquisition and reconstruction parameters showed near-perfect linearity between radiodensity and Ho concentration. The most accurate Ho recoveries on CT were 102 ± 11% in five phantoms and 98 ± 31% in seven canine patients using thresholding methods. Dose estimations and volume histograms were successfully implemented for clinical application using a dose point kernel based on Monte Carlo simulations.
Collapse
Affiliation(s)
- Chiron Morsink
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, PO Box 80154, 3508 TD, Utrecht, The Netherlands.
| | - Nienke Klaassen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands
| | | | - Milou Boswinkel
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands
| | | | - Robin Bruggink
- 3D Lab, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands
| | | | - Irene Schaafsma
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, PO Box 80154, 3508 TD, Utrecht, The Netherlands
| | - Jan Willem Hesselink
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, PO Box 80154, 3508 TD, Utrecht, The Netherlands
| | - Frank Nijsen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Bas van Nimwegen
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, PO Box 80154, 3508 TD, Utrecht, The Netherlands
| |
Collapse
|
4
|
Serhal M, Gordon AC, Brown DB, Toskich BB, Lewandowski RJ. Transarterial Radioembolization: Overview of Radioembolic Devices. Semin Intervent Radiol 2023; 40:461-466. [PMID: 37927522 PMCID: PMC10622244 DOI: 10.1055/s-0043-1772814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2023]
Affiliation(s)
- Muhamad Serhal
- Section of Interventional Radiology, Department of Radiology, Northwestern Memorial Hospital, Robert H. Lurie Comprehensive Cancer Center, Chicago, Illinois
| | - Andrew C. Gordon
- Section of Interventional Radiology, Department of Radiology, Northwestern Memorial Hospital, Robert H. Lurie Comprehensive Cancer Center, Chicago, Illinois
| | - Daniel B. Brown
- Division of Interventional Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Beau B. Toskich
- Division of Interventional Radiology, Mayo Clinic Florida, Jacksonville, Florida
| | - Robert J. Lewandowski
- Section of Interventional Radiology, Department of Radiology, Northwestern Memorial Hospital, Robert H. Lurie Comprehensive Cancer Center, Chicago, Illinois
| |
Collapse
|
5
|
Roosen J, van Wijk MWM, Westlund Gotby LEL, Arntz MJ, Janssen MJR, Lobeek D, van de Maat GH, Overduin CG, Nijsen JFW. Improving MRI-based dosimetry for holmium-166 transarterial radioembolization using a nonrigid image registration for voxelwise Δ R 2 ∗ $\Delta R_2^*$ calculation. Med Phys 2023; 50:935-946. [PMID: 36202392 DOI: 10.1002/mp.16014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 08/16/2022] [Accepted: 09/12/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Transarterial radioembolization (TARE) is a treatment modality for liver tumors during which radioactive microspheres are injected into the hepatic arterial system. These microspheres distribute throughout the liver as a result of the blood flow until they are trapped in the arterioles because of their size. Holmium-166 (166 Ho)-loaded microspheres used for TARE can be visualized and quantified with MRI, as holmium is a paramagnetic metal and locally increases the transverse relaxation rate R 2 ∗ $R_2^*$ . The current 166 Ho quantification method does not take regional differences in baseline R 2 ∗ $R_2^*$ values (such as between tumors and healthy tissue) into account, which intrinsically results in a systematic error in the estimated absorbed dose distribution. As this estimated absorbed dose distribution can be used to predict response to treatment of tumors and potential toxicity in healthy tissue, a high accuracy of absorbed dose estimation is required. PURPOSE To evaluate pre-existing differences in R 2 ∗ $R_2^*$ distributions between tumor tissue and healthy tissue and assess the feasibility and accuracy of voxelwise subtraction-based Δ R 2 ∗ $\Delta R_2^*$ calculation for MRI-based dosimetry of holmium-166 transarterial radioembolization (166 Ho TARE). METHODS MRI data obtained in six patients who underwent 166 Ho TARE of the liver as part of a clinical study was retrospectively evaluated. Pretreatment differences in R 2 ∗ $R_2^*$ distributions between tumor tissue and healthy tissue were characterized. Same-day pre- and post-treatment R 2 ∗ $R_2^*$ maps were aligned using a deformable registration algorithm and subsequently subtracted to generate voxelwise Δ R 2 ∗ $\Delta R_2^*$ maps and resultant absorbed dose maps. Image registration accuracy was quantified using the dice similarity coefficient (DSC), relative overlay (RO), and surface dice (≤4 mm; SDSC). Voxelwise subtraction-based absorbed dose maps were quantitatively (root-mean-square error, RMSE) and visually compared to the current MRI-based mean subtraction method and routinely used SPECT-based dosimetry. RESULTS Pretreatment R 2 ∗ $R_2^*$ values were lower in tumors than in healthy liver tissue (mean 36.8 s-1 vs. 55.7 s-1 , P = 0.004). Image registration improved the mean DSC of 0.83 (range: 0.70-0.88) to 0.95 (range: 0.92-0.97), mean RO of 0.71 (range 0.53-0.78) to 0.90 (range: 0.86-0.94), and mean SDSC ≤4 mm of 0.47 (range: 0.28-0.67) to 0.97 (range: 0.96-0.98). Voxelwise subtraction-based absorbed dose maps yielded a higher tumor-absorbed dose (median increase of 9.0%) and lower healthy liver-absorbed dose (median decrease of 13.8%) compared to the mean subtraction method. Voxelwise subtraction-based absorbed dose maps corresponded better to SPECT-based absorbed dose maps, reflected by a lower RMSE in three of six patients. CONCLUSIONS Voxelwise subtraction presents a robust alternative method for MRI-based dosimetry of 166 Ho microspheres that accounts for pre-existing R 2 ∗ $R_2^*$ differences, and appears to correspond better with SPECT-based dosimetry compared to the currently implemented mean subtraction method.
Collapse
Affiliation(s)
- Joey Roosen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Meike W M van Wijk
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Lovisa E L Westlund Gotby
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Mark J Arntz
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Marcel J R Janssen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Daphne Lobeek
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | | | - Christiaan G Overduin
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - J Frank W Nijsen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
6
|
Osipitan OO, Sun M, Gordish-Dressman H, Wendt R, Wight-Carter M, Balkus KJ, Di Pasqua AJ. Laminated holmium-166-containing electrospun bandages for use against skin cancer. Nucl Med Biol 2022; 114-115:78-85. [PMID: 36270073 DOI: 10.1016/j.nucmedbio.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 10/02/2022] [Accepted: 10/05/2022] [Indexed: 12/27/2022]
Abstract
The number of non-melanoma skin cancer (NMSC) cases in the US will increase significantly over the next decade due to a rise in UV exposure. One of the treatment methods used to remove NMSC lesions is radiation therapy. The two types of radiation therapy used in the clinic are external beam therapy and brachytherapy. However, both require specialized on-site instrumentation and for patients to remain immobile. In this work, we studied an alternative radiation therapy - one that does not require expensive on-site equipment and would allow for enhanced patient mobility and, thus, comfort. We prepared sealed source, nylon-laminated holmium-166-containing radiotherapeutic bandages and used them in C3H/HeN mice with murine SCCVII tumor grafts. Overall, tumor sizes were smallest when treated with therapeutically relevant radiation doses via radiotherapeutic bandages (compared to controls), and no histological evidence of toxicity to tissues was observed. Thus, our optimized radiotherapeutic bandage offers a flexible approach to treating NMSC.
Collapse
Affiliation(s)
- Ositomiwa O Osipitan
- Department of Pharmaceutical Sciences, School of Pharmacy and Pharmaceutical Sciences, Binghamton University, 96 Corliss Ave., Johnson City, NY 13790, United States of America; Department of Biomedical Engineering, The Thomas J. Watson College of Engineering and Applied Science, Binghamton University, 4400 Vestal Pkwy. E., Binghamton, NY 13902, United States of America
| | - Mengwei Sun
- Department of Pharmaceutical Sciences, School of Pharmacy and Pharmaceutical Sciences, Binghamton University, 96 Corliss Ave., Johnson City, NY 13790, United States of America; Department of Biomedical Engineering, The Thomas J. Watson College of Engineering and Applied Science, Binghamton University, 4400 Vestal Pkwy. E., Binghamton, NY 13902, United States of America
| | - Heather Gordish-Dressman
- Center for Translational Science, Division of Biostatistics and Study Design, Children's National Hospital, 111 Michigan Ave NW, Washington, DC 20010, United States of America
| | - Richard Wendt
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Unit 1352, 1515 Holcombe Blvd., Houston, TX 77030, United States of America
| | - Mary Wight-Carter
- Animal Resource Center, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America
| | - Kenneth J Balkus
- Department of Chemistry, University of Texas at Dallas, Richardson, 800 West Campbell Road, Richardson, TX 75080, United States of America.
| | - Anthony J Di Pasqua
- Department of Pharmaceutical Sciences, School of Pharmacy and Pharmaceutical Sciences, Binghamton University, 96 Corliss Ave., Johnson City, NY 13790, United States of America; Department of Biomedical Engineering, The Thomas J. Watson College of Engineering and Applied Science, Binghamton University, 4400 Vestal Pkwy. E., Binghamton, NY 13902, United States of America.
| |
Collapse
|
7
|
Morsink NC, Nijsen JFW, Grinwis GCM, Hesselink JW, Kirpensteijn J, van Nimwegen SA. Intratumoral injection of holmium-166 microspheres as neoadjuvant therapy of soft tissue sarcomas in dogs. Front Vet Sci 2022; 9:1015248. [PMID: 36387397 PMCID: PMC9664058 DOI: 10.3389/fvets.2022.1015248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 10/10/2022] [Indexed: 01/24/2023] Open
Abstract
INTRODUCTION Minimally invasive microbrachytherapy is in development to treat solid tumors by intratumoral injection of (radioactive) holmium-166 (166Ho) microspheres (MS). A high local dose can be administered with minimal damage to surrounding tissue because of the short soft tissue penetration depth of 166Ho beta radiation. We aimed to prospectively evaluate the safety and efficacy of 166Ho microbrachytherapy in client-owned canine patients with soft tissue sarcomas (STS). METHODS We included seven dogs with STS not suitable for local excision due to tumor size and/or location. 166HoMS were suspended in a carrier fluid and multiple needle-injections were performed in predetermined tumor segments to maximize tumor coverage. Tumor response was evaluated using 3D caliper and CT measurements. Follow-up further included monitoring for potential side effects and registration of subsequent treatments and survival, until at least two years after treatment. RESULTS Delivered radioactive doses ranged from 70 to 969 Gy resulting in a mean tumor volume reduction of 49.0 ± 21.3% after 33 ± 25 days. Treatment-related side effects consisted of local necrosis (n = 1) and ulceration of the skin covering the tumor (n = 1), which resolved with basic wound care, and surgical excision of residual tumor, respectively. Residual tumor was surgically resected in six patients after 22-93 days. After a mean follow-up of 1,005 days, four patients were alive, two patients were euthanized because of unrelated causes, and one patient was euthanized because of disease progression after the owner(s) declined subsequent surgical treatment. CONCLUSION 166Ho microbrachytherapy was a safe and effective neoadjuvant treatment option for canine patients with STS.
Collapse
Affiliation(s)
- Nino Chiron Morsink
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, Netherlands,*Correspondence: Nino Chiron Morsink
| | - Johannes Frank Wilhelmus Nijsen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, Netherlands
| | | | - Jan Willem Hesselink
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, Netherlands
| | - Jolle Kirpensteijn
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, Netherlands
| | | |
Collapse
|
8
|
Gulec SA, McGoron AJ. Radiomicrosphere Dosimetry: Principles and Current State of the Art. Semin Nucl Med 2022; 52:215-228. [DOI: 10.1053/j.semnuclmed.2021.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
9
|
Filippi L, Braat AJ. Theragnostics in primary and secondary liver tumors: the need for a personalized approach. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2021; 65:353-370. [PMID: 34881847 DOI: 10.23736/s1824-4785.21.03407-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Primary and secondary hepatic tumors have a dramatic impact in oncology. Despite many advances in diagnosis and therapy, the management of hepatic malignancies is still challenging, ranging from various loco-regional approaches to system therapies. In this scenario, theragnostic approaches, based on the administration of a radiopharmaceuticals' pair, the first labeled with a radionuclide suitable for the diagnostic phase and the second one bound to radionuclide emitting particles for therapy, is gaining more and more importance. Selective internal radiation therapy (SIRT) with microspheres labeled with 90Y or 166Ho is widely used as a loco-regional treatment for primary and secondary hepatic tumors. While 166Ho presents both gamma and beta emission and can be therefore considered a real "theragnostic" agent, for 90Y-microspheres theragnostic approach is realized at the diagnostic phase through the utilization of macroaggregates of human albumin, labeled with 99mTc as "biosimilar" agent respect to microspheres. The aim of the present review was to cover theragnostic applications of 90Y/166Ho-labeled microspheres in clinical practice. Furthermore, we report the preliminary data concerning the potential role of some emerging theragnostic biomarkers for hepatocellular carcinoma, such as glypican-3 (GPC3) and prostate specific membrane antigen (PSMA).
Collapse
Affiliation(s)
- Luca Filippi
- Department of Nuclear Medicine, Santa Maria Goretti Hospital, Latina, Italy -
| | - Arthur J Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
10
|
Morsink NC, Klaassen NJM, Meij BP, Kirpensteijn J, Grinwis GCM, Schaafsma IA, Hesselink JW, Nijsen JFW, van Nimwegen SA. Case Report: Radioactive Holmium-166 Microspheres for the Intratumoral Treatment of a Canine Pituitary Tumor. Front Vet Sci 2021; 8:748247. [PMID: 34805338 PMCID: PMC8600255 DOI: 10.3389/fvets.2021.748247] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 09/27/2021] [Indexed: 11/13/2022] Open
Abstract
Introduction: In this case study, a client-owned dog with a large pituitary tumor was experimentally treated by intratumoral injection of radioactive holmium-166 microspheres (166HoMS), named 166Ho microbrachytherapy. To our knowledge, this is the first intracranial intratumoral treatment through needle injection of radioactive microspheres. Materials and Methods: A 10-year-old Jack Russell Terrier was referred to the Clinic for Companion Animal Health (Faculty of Veterinary Medicine, Utrecht University, The Netherlands) with behavioral changes, restlessness, stiff gait, and compulsive circling. MRI and CT showed a pituitary tumor with basisphenoid bone invasion and marked mass effect. The tumor measured 8.8 cm3 with a pituitary height-to-brain area (P/B) ratio of 1.86 cm-1 [pituitary height (cm) ×10/brain area (cm2)]. To reduce tumor volume and neurological signs, 166HoMS were administered in the tumor center by transsphenoidal CT-guided needle injections. Results: Two manual CT-guided injections were performed containing 0.6 ml of 166HoMS suspension in total. A total of 1097 MBq was delivered, resulting in a calculated average tumor dose of 1866 Gy. At 138 days after treatment, the tumor volume measured 5.3 cm3 with a P/B ratio of 1.41 cm-1, revealing a total tumor volume reduction of 40%. Debulking surgery was performed five months after 166HoMS treatment due to recurrent neurological signs. The patient was euthanized two weeks later at request of the owners. Histopathological analysis indicated a pituitary adenoma at time of treatment, with more malignant characteristics during debulking surgery. Conclusion: The 40% tumor volume reduction without evident severe periprocedural side effects demonstrated the feasibility of intracranial intratumoral 166HoMS treatment in this single dog.
Collapse
Affiliation(s)
- Nino Chiron Morsink
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, Netherlands
| | - Nienke Johanna Maria Klaassen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, Netherlands
| | - Björn Petrus Meij
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, Netherlands
| | - Jolle Kirpensteijn
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, Netherlands
| | | | - Irene Afra Schaafsma
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, Netherlands
| | - Jan Willem Hesselink
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, Netherlands
| | - Johannes Frank Wilhelmus Nijsen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, Netherlands
- Quirem Medical, Deventer, Netherlands
| | | |
Collapse
|
11
|
de Vries M, Klaassen NJM, Morsink NC, van Nimwegen SA, Nijsen JFW, van den Dobbelsteen JJ. Dedicated holmium microsphere administration device for MRI-guided interstitial brain microbrachytherapy. Med Eng Phys 2021; 96:13-21. [PMID: 34565548 DOI: 10.1016/j.medengphy.2021.07.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Revised: 07/15/2021] [Accepted: 07/21/2021] [Indexed: 01/22/2023]
Abstract
Microbrachytherapy with radioactive holmium-166 (166Ho) microspheres (MS) has the potential to be an effective treatment method for brain malignancies. Direct intratumoural delivery of 166Ho-MS and dose coverage of the whole tumour are crucial requirements. However, currently no dedicated instruments for controlled intratumoural delivery exist. This study presents an administration device that facilitates this novel magnetic resonance imaging (MRI) -guided intervention. The bioceramic alumina oxide cannula creates a straight channel for a superelastic nitinol precurved stylet to control spatial deposition of Ho-MS. End-point accuracy of the stylet was measured during insertions in phantoms. Imaging tests were performed in a 3 Tesla MRI-scanner to quantify instrument-induced artefacts. Additionally, the feasibility of non-radioactive holmium-165 (165Ho)-MS delivery with the administration device was evaluated in a brain tumour simulant. Absolute stylet tip error was 0.88 ± 0.61 mm, instrument distortion in MRI depended on needle material and orientation and dose delivery of 165Ho-MS in a brain tumour phantom was possible. This study shows that the administration device can accurately place the stylet for injection of Ho-MS and that visualization can be performed with MRI.
Collapse
Affiliation(s)
- M de Vries
- Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, Delft 2628 CD, the Netherlands.
| | - N J M Klaassen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud university Medical Center, Geert Grooteplein Zuid 10, Nijmegen 6525 GA, the Netherlands
| | - N C Morsink
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 108, Utrecht 3508 TD, the Netherlands
| | - S A van Nimwegen
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 108, Utrecht 3508 TD, the Netherlands
| | - J F W Nijsen
- Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud university Medical Center, Geert Grooteplein Zuid 10, Nijmegen 6525 GA, the Netherlands; Quirem Medical B.V., Zutphenseweg 55, Deventer 7418 AH, the Netherlands
| | - J J van den Dobbelsteen
- Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, Delft 2628 CD, the Netherlands
| |
Collapse
|
12
|
d’Abadie P, Hesse M, Louppe A, Lhommel R, Walrand S, Jamar F. Microspheres Used in Liver Radioembolization: From Conception to Clinical Effects. Molecules 2021; 26:3966. [PMID: 34209590 PMCID: PMC8271370 DOI: 10.3390/molecules26133966] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 01/31/2023] Open
Abstract
Inert microspheres, labeled with several radionuclides, have been developed during the last two decades for the intra-arterial treatment of liver tumors, generally called Selective Intrahepatic radiotherapy (SIRT). The aim is to embolize microspheres into the hepatic capillaries, accessible through the hepatic artery, to deliver high levels of local radiation to primary (such as hepatocarcinoma, HCC) or secondary (metastases from several primary cancers, e.g., colorectal, melanoma, neuro-endocrine tumors) liver tumors. Several types of microspheres were designed as medical devices, using different vehicles (glass, resin, poly-lactic acid) and labeled with different radionuclides, 90Y and 166Ho. The relationship between the microspheres' properties and the internal dosimetry parameters have been well studied over the last decade. This includes data derived from the clinics, but also computational data with various millimetric dosimetry and radiobiology models. The main purpose of this paper is to define the characteristics of these radiolabeled microspheres and explain their association with the microsphere distribution in the tissues and with the clinical efficacy and toxicity. This review focuses on avenues to follow in the future to optimize such particle therapy and benefit to patients.
Collapse
Affiliation(s)
- Philippe d’Abadie
- Department of Nuclear Medicine, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium; (M.H.); (A.L.); (R.L.); (S.W.); (F.J.)
| | | | | | | | | | | |
Collapse
|
13
|
Filippi L, Chiaravalloti A, Schillaci O, Cianni R, Bagni O. Theranostic approaches in nuclear medicine: current status and future prospects. Expert Rev Med Devices 2020; 17:331-343. [PMID: 32157920 DOI: 10.1080/17434440.2020.1741348] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Introduction: Theranostics is an emerging field in which diagnosis and specific targeted therapy are combined to achieve a personalized treatment approach to the patient. In nuclear medicine clinical practice, theranostics is often performed utilizing the same molecule labeled with two different radionuclides, one radionuclide for imaging and another for therapy.Areas covered: The authors review the clinical applications of different radiopharmaceuticals in the field of interest, including the well-established use of radioactive iodine in differentiated thyroid cancer, radiolabeled metaiodobenzylguanidine (MIBG) in neuroblastoma and the clinical impact of peptide radionuclide receptorial therapy (PRRT) in the management of neuroendocrine tumors. Furthermore, the more cutting-edge and recently introduced theranostic approaches will be reviewed, such as the radioligand therapy with 177Lu-prostate specific membrane antigen (PSMA) and targeted alpha therapy in castration-resistant prostate cancer. Finally, the main applications of PET for the imaging of biomarkers suitable for the non-radionuclide targeted therapy will be covered.Expert opinion: Theranostics is envisaging a revolutionary clinical approach which is deeply connected with the concept of personalized medicine and ruled by a 'patient-centered' vision. In this perspective, the theranostic applications will need well-trained specialists, capable to manage not only the technological aspects of the discipline, but also to deal with the more innovative oncological therapies in a multidisciplinary setting.
Collapse
Affiliation(s)
- Luca Filippi
- Department of Nuclear Medicine, Santa Maria Goretti Hospital, Latina, Italy
| | - Agostino Chiaravalloti
- Department of Biomedicine and Prevention, University Tor Vergata, Rome, Italy.,IRCCS Neuromed, Pozzilli, Italy
| | - Orazio Schillaci
- Department of Biomedicine and Prevention, University Tor Vergata, Rome, Italy.,IRCCS Neuromed, Pozzilli, Italy
| | - Roberto Cianni
- Department of Interventional Radiology, S. Camillo Hospital, Rome, Italy
| | - Oreste Bagni
- Department of Nuclear Medicine, Santa Maria Goretti Hospital, Latina, Italy
| |
Collapse
|
14
|
Smits MLJ, Dassen MG, Prince JF, Braat AJAT, Beijst C, Bruijnen RCG, de Jong HWAM, Lam MGEH. The superior predictive value of 166Ho-scout compared with 99mTc-macroaggregated albumin prior to 166Ho-microspheres radioembolization in patients with liver metastases. Eur J Nucl Med Mol Imaging 2019; 47:798-806. [PMID: 31399801 PMCID: PMC7075844 DOI: 10.1007/s00259-019-04460-y] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Accepted: 07/23/2019] [Indexed: 12/11/2022]
Abstract
Purpose As an alternative to technetium-99m-macroaggregated albumin (99mTc-MAA), a scout dose of holmium-166 (166Ho) microspheres can be used prior to 166Ho-radioembolization. The use of identical particles for pre-treatment and treatment procedures may improve the predictive value of pre-treatment analysis of distribution. The aim of this study was to analyze the agreement between 166Ho-scout and 166Ho-therapeutic dose in comparison with the agreement between 99mTc-MAA and 166Ho-therapeutic dose. Methods Two separate scout dose procedures were performed (99mTc-MAA and 166Ho-scout) before treatment in 53 patients. First, qualitative assessment was performed by two blinded nuclear medicine physicians who visually rated the agreement between the 99mTc-MAA, 166Ho-scout, and 166Ho-therapeutic dose SPECT-scans (i.e., all performed in the same patient) on a 5-point scale. Second, agreement was measured quantitatively by delineating lesions and normal liver on FDG-PET/CT. These volumes of interest (VOIs) were co-registered to the SPECT/CT images. The predicted absorbed doses (based on 99mTc-MAA and 166Ho-scout) were compared with the actual absorbed dose on post-treatment SPECT. Results A total of 23 procedures (71 lesions, 22 patients) were included for analysis. In the qualitative analysis, 166Ho-scout was superior with a median score of 4 vs. 2.5 for 99mTc-MAA (p < 0.001). The quantitative analysis showed significantly narrower 95%-limits of agreement for 166Ho-scout in comparison with 99mTc-MAA when evaluating lesion absorbed dose (− 90.3 and 105.3 Gy vs. − 164.1 and 197.0 Gy, respectively). Evaluation of normal liver absorbed dose did not show difference in agreement between both scout doses and 166Ho-therapeutic dose (− 2.9 and 5.5 Gy vs − 3.6 and 4.1 Gy for 99mTc-MAA and 166Ho-scout, respectively). Conclusions In this study, 166Ho-scout was shown to have a superior predictive value for intrahepatic distribution in comparison with 99mTc-MAA.
Collapse
Affiliation(s)
- Maarten L J Smits
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Mathijs G Dassen
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Jip F Prince
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Arthur J A T Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Casper Beijst
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Rutger C G Bruijnen
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Hugo W A M de Jong
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Marnix G E H Lam
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| |
Collapse
|
15
|
Klaassen NJM, Arntz MJ, Gil Arranja A, Roosen J, Nijsen JFW. The various therapeutic applications of the medical isotope holmium-166: a narrative review. EJNMMI Radiopharm Chem 2019; 4:19. [PMID: 31659560 PMCID: PMC6682843 DOI: 10.1186/s41181-019-0066-3] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 07/05/2019] [Indexed: 12/17/2022] Open
Abstract
Over the years, a broad spectrum of applications of the radionuclide holmium-166 as a medical isotope has been established. The isotope holmium-166 is attractive as it emits high-energy beta radiation which can be used for a therapeutic effect and gamma radiation which can be used for nuclear imaging purposes. Furthermore, holmium-165 can be visualized by MRI because of its paramagnetic properties and by CT because of its high density. Since holmium-165 has a natural abundance of 100%, the only by-product is metastable holmium-166 and no costly chemical purification steps are necessary for production of nuclear reactor derived holmium-166. Several compounds labelled with holmium-166 are now used in patients, such Ho166-labelled microspheres for liver malignancies, Ho166-labelled chitosan for hepatocellular carcinoma (HCC) and [166Ho]Ho DOTMP for bone metastases. The outcomes in patients are very promising, making this isotope more and more interesting for applications in interventional oncology. Both drugs as well as medical devices labelled with radioactive holmium are used for internal radiotherapy. One of the treatment possibilities is direct intratumoural treatment, in which the radioactive compound is injected with a needle directly into the tumour. Numerous other applications have been developed, like patches for treatment of skin cancer and holmium labelled antibodies and peptides. The second major application that is currently clinically applied is selective internal radiation therapy (SIRT, also called radioembolization), a novel treatment option for liver malignancies. This review discusses medical drugs and medical devices based on the therapeutic radionuclide holmium-166.
Collapse
Affiliation(s)
- Nienke J M Klaassen
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Radboud Institute for Health Sciences, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands
| | - Mark J Arntz
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Radboud Institute for Health Sciences, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands
| | - Alexandra Gil Arranja
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Radboud Institute for Health Sciences, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands.,Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences (UIPS), Science for Life, Faculty of Science, Utrecht University, 3508, TB, Utrecht, The Netherlands.,Department of Radiation Science and Technology, Delft University of Technology, Mekelweg 15, 2629, JB, Delft, The Netherlands
| | - Joey Roosen
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Radboud Institute for Health Sciences, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands
| | - J Frank W Nijsen
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Radboud Institute for Health Sciences, Geert Grooteplein Zuid 10, 6525, GA, Nijmegen, The Netherlands.
| |
Collapse
|
16
|
Reinders MTM, Smits MLJ, van Roekel C, Braat AJAT. Holmium-166 Microsphere Radioembolization of Hepatic Malignancies. Semin Nucl Med 2019; 49:237-243. [PMID: 30954190 DOI: 10.1053/j.semnuclmed.2019.01.008] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Holmium microspheres have recently become available in the European market as the third type of microspheres for radioembolization of unresectable liver malignancies. Holmium microspheres come with a dedicated administration system, and since these microspheres contain holmium-166 (166Ho) instead of yttrium-90, unique dosing and imaging possibilities have become available as well. In addition, a scout dose of 166Ho microspheres (Conformité Européenne mark is now granted and not pending anymore) can be used instead of 99mTc-macroaggragated albumin during the preparatory angiography procedure. So far, two prospective phase I and phase II clinical studies have been performed on 166Ho radioembolization in a population of liver metastases from mixed origins. These studies showed that a mean whole-liver dose of 60 Gy is safe and induces tumor response. Ongoing trials investigate the effect of 166Ho radioembolization in patients with neuroendocrine tumor metastases, hepatocellular carcinoma, and colorectal cancer metastases. Data derived from these studies will be used to refine the dosing schedule of 60 Gy to the whole liver and determine the optimal level of activity for each patient. This paper discusses several basics and provides an overview of relevant dosing aspects, technical aspects of performing holmium radioembolization, as well as a summary of completed and ongoing clinical studies and the upcoming developments regarding these microspheres.
Collapse
|
17
|
Radosa CG, Radosa JC, Grosche-Schlee S, Zöphel K, Plodeck V, Kühn JP, Kotzerke J, Hoffmann RT. Holmium-166 Radioembolization in Hepatocellular Carcinoma: Feasibility and Safety of a New Treatment Option in Clinical Practice. Cardiovasc Intervent Radiol 2019; 42:405-412. [PMID: 30603976 DOI: 10.1007/s00270-018-2133-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2018] [Accepted: 11/22/2018] [Indexed: 12/18/2022]
Abstract
PURPOSE To investigate clinical feasibility, technical success and toxicity of 166Ho-radioembolization (166Ho-RE) as new approach for treatment of hepatocellular carcinomas (HCC) and to assess postinterventional calculation of exact dosimetry through quantitative analysis of MR images. MATERIALS AND METHODS From March 2017 to April 2018, nine patients suffering from HCC were treated with 166Ho-RE. To calculate mean doses on healthy liver/tumor tissue, MR was performed within the first day after treatment. For evaluation of hepatotoxicity and to rule out radioembolization-induced liver disease (REILD), the Model for End-Stage Liver Disease (MELD) Score, the Common Terminology Criteria for Adverse Events and specific laboratory parameters were used 1-day pre- and posttreatment and after 60 days. After 6 months, MR/CT follow-up was performed. RESULTS In five patients the right liver lobe, in one patient the left liver lobe and in three patients both liver lobes were treated. Median administered activity was 3.7 GBq (range 1.7-5.9 GBq). Median dose on healthy liver tissue was 41 Gy (21-55 Gy) and on tumor tissue 112 Gy (61-172 Gy). Four patients suffered from mild postradioembolization syndrome. No significant differences in median MELD-Score were observed pre-, posttherapeutic and 60 days after 166Ho-RE. No deterioration of liver function and no indicators of REILD were observed. One patient showed a complete response, four a partial response, three a stable disease and one a progressive disease at the 6 months follow-up. CONCLUSION 166Ho-RE seems to be a feasible and safe treatment option with no significant hepatotoxicity for treatment of HCC.
Collapse
Affiliation(s)
- Christoph G Radosa
- Institute and Policlinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Julia C Radosa
- Department of Gynecology and Obstetrics, Saarland University Hospital, Kirrbergerstraße 100, 66421, Homburg, Germany
| | - Sabine Grosche-Schlee
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Klaus Zöphel
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Verena Plodeck
- Institute and Policlinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Jens P Kühn
- Institute and Policlinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Jörg Kotzerke
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Ralf-Thorsten Hoffmann
- Institute and Policlinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
| |
Collapse
|
18
|
Bouvry C, Palard X, Edeline J, Ardisson V, Loyer P, Garin E, Lepareur N. Transarterial Radioembolization (TARE) Agents beyond 90Y-Microspheres. BIOMED RESEARCH INTERNATIONAL 2018; 2018:1435302. [PMID: 30687734 PMCID: PMC6330886 DOI: 10.1155/2018/1435302] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Accepted: 12/19/2018] [Indexed: 12/14/2022]
Abstract
Liver malignancies, either primary tumours (mainly hepatocellular carcinoma and cholangiocarcinoma) or secondary hepatic metastases, are a major cause of death, with an increasing incidence. Among them, hepatocellular carcinoma (HCC) presents with a dark prognosis because of underlying liver diseases and an often late diagnosis. A curative surgical treatment can therefore only be proposed in 20 to 30% of the patients. However, new treatment options for intermediate to advanced stages, such as internal radionuclide therapy, seem particularly attractive. Transarterial radioembolization (TARE), which consists in the use of intra-arterial injection of a radiolabelled embolising agent, has led to very promising results. TARE with 90Y-loaded microspheres is now becoming an established procedure to treat liver tumours, with two commercially available products (namely, SIR-Sphere® and TheraSphere®). However, this technology remains expensive and is thus not available everywhere. The aim of this review is to describe TARE alternative technologies currently developed and investigated in clinical trials, with special emphasis on HCC.
Collapse
Affiliation(s)
- C. Bouvry
- Comprehensive Cancer Centre Eugène Marquis, 35042 Rennes, France
- Univ Rennes, CNRS, ISCR (Institut des Sciences Chimiques de Rennes), UMR 6226, 35000 Rennes, France
| | - X. Palard
- Comprehensive Cancer Centre Eugène Marquis, 35042 Rennes, France
- Univ Rennes, Inserm, LTSI (Laboratoire Traitement du Signal et de l'Image), UMR_S 1099, 35000 Rennes, France
| | - J. Edeline
- Comprehensive Cancer Centre Eugène Marquis, 35042 Rennes, France
- Univ Rennes, Inra, Inserm, Institut NUMECAN (Nutrition, Métabolismes et Cancer), UMR_A 1341, UMR_S 1241, 35000 Rennes, France
| | - V. Ardisson
- Comprehensive Cancer Centre Eugène Marquis, 35042 Rennes, France
| | - P. Loyer
- Univ Rennes, Inra, Inserm, Institut NUMECAN (Nutrition, Métabolismes et Cancer), UMR_A 1341, UMR_S 1241, 35000 Rennes, France
| | - E. Garin
- Comprehensive Cancer Centre Eugène Marquis, 35042 Rennes, France
- Univ Rennes, Inra, Inserm, Institut NUMECAN (Nutrition, Métabolismes et Cancer), UMR_A 1341, UMR_S 1241, 35000 Rennes, France
| | - N. Lepareur
- Comprehensive Cancer Centre Eugène Marquis, 35042 Rennes, France
- Univ Rennes, Inra, Inserm, Institut NUMECAN (Nutrition, Métabolismes et Cancer), UMR_A 1341, UMR_S 1241, 35000 Rennes, France
| |
Collapse
|
19
|
D'Arienzo M, Pimpinella M, Capogni M, De Coste V, Filippi L, Spezi E, Patterson N, Mariotti F, Ferrari P, Chiaramida P, Tapner M, Fischer A, Paulus T, Pani R, Iaccarino G, D'Andrea M, Strigari L, Bagni O. Phantom validation of quantitative Y-90 PET/CT-based dosimetry in liver radioembolization. EJNMMI Res 2017; 7:94. [PMID: 29185067 PMCID: PMC5705539 DOI: 10.1186/s13550-017-0341-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 10/29/2017] [Indexed: 12/20/2022] Open
Abstract
Background PET/CT has recently been shown to be a viable alternative to traditional post-infusion imaging methods providing good quality images of 90Y-laden microspheres after selective internal radiation therapy (SIRT). In the present paper, first we assessed the quantitative accuracy of 90Y-PET using an anthropomorphic phantom provided with lungs, liver, spine, and a cylindrical homemade lesion located into the hepatic compartment. Then, we explored the accuracy of different computational approaches on dose calculation, including (I) direct Monte Carlo radiation transport using Raydose, (II) Kernel convolution using Philips Stratos, (III) local deposition algorithm, (IV) Monte Carlo technique (MCNP) considering a uniform activity distribution, and (V) MIRD (Medical Internal Radiation Dose) analytical approach. Finally, calculated absorbed doses were compared with those obtained performing measurements with LiF:Mg,Cu,P TLD chips in a liquid environment. Results Our results indicate that despite 90Y-PET being likely to provide high-resolution images, the 90Y low branch ratio, along with other image-degrading factors, may produce non-uniform activity maps, even in the presence of uniform activity. A systematic underestimation of the recovered activity, both for the tumor insert and for the liver background, was found. This is particularly true if no partial volume correction is applied through recovery coefficients. All dose algorithms performed well, the worst case scenario providing an agreement between absorbed dose evaluations within 20%. Average absorbed doses determined with the local deposition method are in excellent agreement with those obtained using the MIRD and the kernel-convolution dose calculation approach. Finally, absorbed dose assessed with MC codes are in good agreement with those obtained using TLD in liquid solution, thus confirming the soundness of both calculation approaches. This is especially true for Raydose, which provided an absorbed dose value within 3% of the measured dose, well within the stated uncertainties. Conclusions Patient-specific dosimetry is possible even in a scenario with low true coincidences and high random fraction, as in 90Y–PET imaging, granted that accurate absolute PET calibration is performed and acquisition times are sufficiently long. Despite Monte Carlo calculations seeming to outperform all dose estimation algorithms, our data provide a strong argument for encouraging the use of the local deposition algorithm for routine 90Y dosimetry based on PET/CT imaging, due to its simplicity of implementation.
Collapse
Affiliation(s)
- Marco D'Arienzo
- ENEA, Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese 301, 00123, Rome, Italy. .,Department of Anatomical, Histological, Forensic Medicine and Orthopedic Sciences, Sapienza University, Rome, Italy.
| | - Maria Pimpinella
- ENEA, Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese 301, 00123, Rome, Italy
| | - Marco Capogni
- ENEA, Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese 301, 00123, Rome, Italy
| | - Vanessa De Coste
- ENEA, Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese 301, 00123, Rome, Italy
| | - Luca Filippi
- Nuclear Medicine Department, Santa Maria Goretti Hospital, Latina, Italy
| | - Emiliano Spezi
- School of Engineering, Cardiff University, Cardiff, CF24 3AA, United Kingdom.,Department of Medical Physics, Velindre Cancer Centre, Cardiff, UK
| | - Nick Patterson
- Department of Medical Physics, Velindre Cancer Centre, Cardiff, UK
| | - Francesca Mariotti
- ENEA, Radiation Protection Institute, Bologna Via Martiri di Monte Sole 4, 40129, Bologna, Italy
| | - Paolo Ferrari
- ENEA, Radiation Protection Institute, Bologna Via Martiri di Monte Sole 4, 40129, Bologna, Italy
| | | | | | - Alexander Fischer
- Philips Technologie GmbH Innovative Technologies, Research Laboratories Pauwelsstr, 17, 52074, Aachen, Germany
| | - Timo Paulus
- Philips Technologie GmbH Innovative Technologies, Research Laboratories Pauwelsstr, 17, 52074, Aachen, Germany
| | - Roberto Pani
- Depertment of Medico-surgical Sciences and Biotecnologies, Sapienza University of Rome, Rome, Italy
| | - Giuseppe Iaccarino
- Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer Institute, Via Elio Chianesi 53, 00144, Rome, Italy
| | - Marco D'Andrea
- Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer Institute, Via Elio Chianesi 53, 00144, Rome, Italy
| | - Lidia Strigari
- Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer Institute, Via Elio Chianesi 53, 00144, Rome, Italy
| | - Oreste Bagni
- Nuclear Medicine Department, Santa Maria Goretti Hospital, Latina, Italy
| |
Collapse
|
20
|
Affiliation(s)
- Yi Shi
- Department of Pharmaceutical Sciences, School of Pharmacy and Pharmaceutical Sciences, Binghamton University, Binghamton, New York, USA
| | - Amanda M. Johnsen
- Radiation Science and Engineering Center, Pennsylvania State University, University Park, Pennsylvania, USA
| | - Anthony J. Di Pasqua
- Department of Pharmaceutical Sciences, School of Pharmacy and Pharmaceutical Sciences, Binghamton University, Binghamton, New York, USA
| |
Collapse
|
21
|
Oerlemans C, Seevinck PR, Smits ML, Hennink WE, Bakker CJG, van den Bosch MAAJ, Nijsen JFW. Holmium-lipiodol-alginate microspheres for fluoroscopy-guided embolotherapy and multimodality imaging. Int J Pharm 2014; 482:47-53. [PMID: 25448561 DOI: 10.1016/j.ijpharm.2014.11.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2014] [Revised: 10/30/2014] [Accepted: 11/04/2014] [Indexed: 12/20/2022]
Abstract
Embolotherapy is a minimally invasive transcatheter technique aiming at reduction or complete obstruction of the blood flow by infusion of micro-sized particles in order to induce tumor regression. A major drawback of the current commercially available and clinically used microspheres is that they cannot be detected in vivo with medical imaging techniques, impeding intra- and post-procedural feedback. It can be expected that real-time monitoring of microsphere infusion and post-procedural imaging will result in better predictability and higher efficacy of the treatment. In this study, a novel microsphere formulation has been developed that can be visualized with fluoroscopy, X-ray computed tomography (CT) and magnetic resonance imaging (MRI). The microspheres were prepared with the JetCutter technique and consist of alginate (matrix-forming polymer), holmium (cross-linking and MRI contrast agent), lipiodol (radiopaque contrast agent) and Pluronic F-68 (surfactant). The mean size (±SEM) of the hydrated holmium-lipiodol-alginate microspheres (Ho-lip-ams) was 570±12 μm with a holmium content of 0.38±0.01% (w/w). Stability studies showed that the microspheres remained intact during incubation for two weeks in fetal calf serum (FCS) at 37 °C. The inclusion of lipiodol in the microspheres rendered excellent visualization capabilities for fluoroscopy and CT, whereas the holmium ions, which keep the alginate network together, also allow MR imaging. In this study it was shown that single sphere detection was possible by fluoroscopy, CT and MRI. The Ho-lip-ams were visualized in real-time, during infusion in a porcine kidney using fluoroscopy, and post-procedural, the deposition of the microspheres was examined with fluoroscopy, (cone beam rotational) CT and MRI. The different imaging modalities showed similar deposition patterns of the microspheres within the organ. The combination of intra-procedural visualization, multimodality imaging for patient follow-up and the possibility of quantification offers a new and promising method for more safe, efficient and successful embolization treatment.
Collapse
Affiliation(s)
- Chris Oerlemans
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands.
| | - Peter R Seevinck
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Maarten L Smits
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Wim E Hennink
- Department of Pharmaceutics, Utrecht University, Utrecht, The Netherlands
| | - Chris J G Bakker
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - J Frank W Nijsen
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
22
|
Elschot M, Smits MLJ, Nijsen JFW, Lam MGEH, Zonnenberg BA, van den Bosch MAAJ, Viergever MA, de Jong HWAM. Quantitative Monte Carlo-based holmium-166 SPECT reconstruction. Med Phys 2014; 40:112502. [PMID: 24320461 DOI: 10.1118/1.4823788] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
PURPOSE Quantitative imaging of the radionuclide distribution is of increasing interest for microsphere radioembolization (RE) of liver malignancies, to aid treatment planning and dosimetry. For this purpose, holmium-166 ((166)Ho) microspheres have been developed, which can be visualized with a gamma camera. The objective of this work is to develop and evaluate a new reconstruction method for quantitative (166)Ho SPECT, including Monte Carlo-based modeling of photon contributions from the full energy spectrum. METHODS A fast Monte Carlo (MC) simulator was developed for simulation of (166)Ho projection images and incorporated in a statistical reconstruction algorithm (SPECT-fMC). Photon scatter and attenuation for all photons sampled from the full (166)Ho energy spectrum were modeled during reconstruction by Monte Carlo simulations. The energy- and distance-dependent collimator-detector response was modeled using precalculated convolution kernels. Phantom experiments were performed to quantitatively evaluate image contrast, image noise, count errors, and activity recovery coefficients (ARCs) of SPECT-fMC in comparison with those of an energy window-based method for correction of down-scattered high-energy photons (SPECT-DSW) and a previously presented hybrid method that combines MC simulation of photopeak scatter with energy window-based estimation of down-scattered high-energy contributions (SPECT-ppMC+DSW). Additionally, the impact of SPECT-fMC on whole-body recovered activities (A(est)) and estimated radiation absorbed doses was evaluated using clinical SPECT data of six (166)Ho RE patients. RESULTS At the same noise level, SPECT-fMC images showed substantially higher contrast than SPECT-DSW and SPECT-ppMC+DSW in spheres ≥ 17 mm in diameter. The count error was reduced from 29% (SPECT-DSW) and 25% (SPECT-ppMC+DSW) to 12% (SPECT-fMC). ARCs in five spherical volumes of 1.96-106.21 ml were improved from 32%-63% (SPECT-DSW) and 50%-80% (SPECT-ppMC+DSW) to 76%-103% (SPECT-fMC). Furthermore, SPECT-fMC recovered whole-body activities were most accurate (A(est) = 1.06 × A - 5.90 MBq, R(2) = 0.97) and SPECT-fMC tumor absorbed doses were significantly higher than with SPECT-DSW (p = 0.031) and SPECT-ppMC+DSW (p = 0.031). CONCLUSIONS The quantitative accuracy of (166)Ho SPECT is improved by Monte Carlo-based modeling of the image degrading factors. Consequently, the proposed reconstruction method enables accurate estimation of the radiation absorbed dose in clinical practice.
Collapse
Affiliation(s)
- Mattijs Elschot
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
23
|
van de Maat GH, de Leeuw H, Seevinck PR, van den Bosch MAAJ, Nijsen JFW, Bakker CJG. Simultaneous R2*, R2, and R2′ quantification by combining S0estimation of the free induction decay with a single spin echo: A single acquisition method for R2insensitive quantification of holmium-166-loaded microspheres. Magn Reson Med 2014; 73:273-83. [DOI: 10.1002/mrm.25138] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 12/19/2013] [Accepted: 12/31/2013] [Indexed: 01/14/2023]
Affiliation(s)
- G. H. van de Maat
- Image Sciences Institute; University Medical Center Utrecht; Utrecht The Netherlands
| | - H. de Leeuw
- Image Sciences Institute; University Medical Center Utrecht; Utrecht The Netherlands
| | - P. R. Seevinck
- Image Sciences Institute; University Medical Center Utrecht; Utrecht The Netherlands
| | - M. A. A. J. van den Bosch
- Department of Radiology and Nuclear Medicine; University Medical Center Utrecht; Utrecht The Netherlands
| | - J. F. W. Nijsen
- Department of Radiology and Nuclear Medicine; University Medical Center Utrecht; Utrecht The Netherlands
| | - C. J. G. Bakker
- Department of Radiology and Nuclear Medicine; University Medical Center Utrecht; Utrecht The Netherlands
| |
Collapse
|
24
|
van den Hoven AF, Smits MLJ, Rosenbaum CENM, Verkooijen HM, van den Bosch MAAJ, Lam MGEH. The effect of intra-arterial angiotensin II on the hepatic tumor to non-tumor blood flow ratio for radioembolization: a systematic review. PLoS One 2014; 9:e86394. [PMID: 24466071 PMCID: PMC3895031 DOI: 10.1371/journal.pone.0086394] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2013] [Accepted: 12/06/2013] [Indexed: 12/23/2022] Open
Abstract
PURPOSE Treatment efficacy of intra-arterial radioembolization for liver tumors depends on the selective targeting of tumorous tissue. Recent investigations have demonstrated that tumors may receive inadequate doses of radioactivity after radioembolization, due to unfavorable tumor to non-tumor (T/N) uptake ratios of radioactive microspheres. Hepatic arterial infusion of the vasoconstrictor angiotensin II (AT-II) is reported to increase the T/N blood flow ratio. The purpose of this systematic review was to provide a comprehensive overview of the effect of hepatic arterial AT-II on T/N blood flow ratio in patients with hepatic malignancies, and determine its clinical value for radioembolization. METHODS This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A structured search was performed in the PubMed, EMBASE and Cochrane databases. Only studies that presented data on T/N ratios before and after infusion of AT-II into the hepatic artery, in human patients with hepatic malignancies, were selected. Median T/N ratios before, during and after AT-II infusion, and the median T/N ratio improvement factor were extracted from the selected articles. All data on systemic blood pressure measurements and clinical symptoms were also extracted. RESULTS The search identified 524 titles of which 5 studies, including a total of 71 patients were considered relevant. Median T/N ratios before infusion of AT-II ranged from 0.4 to 3.4. All studies observed a substantial improvement of the T/N ratio after AT-II infusion, with median improvement factors ranging from 1.8 to 3.1. A transitory increase of systemic blood pressure was observed during AT-II infusion. CONCLUSIONS Infusion of AT-II into the hepatic artery leads to an increase of the tumor to non-tumor blood flow ratio, as measured by T/N uptake ratios. Clinical trials are warranted to assess safety aspects, optimal administration strategy and impact on treatment efficacy during radioembolization.
Collapse
Affiliation(s)
- Andor F. van den Hoven
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Maarten L. J. Smits
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - Helena M. Verkooijen
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - Marnix G. E. H. Lam
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
25
|
Smits MLJ, Elschot M, van den Bosch MAAJ, van de Maat GH, van het Schip AD, Zonnenberg BA, Seevinck PR, Verkooijen HM, Bakker CJ, de Jong HWAM, Lam MGEH, Nijsen JFW. In vivo dosimetry based on SPECT and MR imaging of 166Ho-microspheres for treatment of liver malignancies. J Nucl Med 2013; 54:2093-100. [PMID: 24136931 DOI: 10.2967/jnumed.113.119768] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
UNLABELLED (166)Ho-poly(l-lactic acid) microspheres allow for quantitative imaging with MR imaging or SPECT for microsphere biodistribution assessment after radioembolization. The purpose of this study was to evaluate SPECT- and MR imaging-based dosimetry in the first patients treated with (166)Ho radioembolization. METHODS Fifteen patients with unresectable, chemorefractory liver metastases of any origin were enrolled in this phase 1 study and were treated with (166)Ho radioembolization according to a dose escalation protocol (20-80 Gy). The contours of all liver segments and all discernible tumors were manually delineated on T2-weighted posttreatment MR images and registered to the posttreatment SPECT images (n = 9) or SPECT/CT images (n = 6) and MR imaging-based R2* maps (n = 14). Dosimetry was based on SPECT (n = 15) and MR imaging (n = 9) for all volumes of interest, tumor-to-nontumor (T/N) activity concentration ratios were calculated, and correlation and agreement of MR imaging- and SPECT-based measurements were evaluated. RESULTS The median overall T/N ratio was 1.4 based on SPECT (range, 0.9-2.8) and 1.4 based on MR imaging (range, 1.1-3.1). In 6 of 15 patients (40%), all tumors had received an activity concentration equal to or higher than the normal liver (T/N ratio ≥ 1). Analysis of SPECT and MR imaging measurements for dose to liver segments yielded a high correlation (R(2) = 0.91) and a moderate agreement (mean bias, 3.7 Gy; 95% limits of agreement, -11.2 to 18.7). CONCLUSION With the use of (166)Ho-microspheres, in vivo dosimetry is feasible on the basis of both SPECT and MR imaging, which enables personalized treatment by selective targeting of inadequately treated tumors.
Collapse
Affiliation(s)
- Maarten L J Smits
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands; and
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Bult W, Kroeze SGC, Elschot M, Seevinck PR, Beekman FJ, de Jong HWAM, Uges DRA, Kosterink JGW, Luijten PR, Hennink WE, van het Schip AD, Bosch JLHR, Nijsen JFW, Jans JJM. Intratumoral administration of holmium-166 acetylacetonate microspheres: antitumor efficacy and feasibility of multimodality imaging in renal cancer. PLoS One 2013; 8:e52178. [PMID: 23320070 PMCID: PMC3540022 DOI: 10.1371/journal.pone.0052178] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Accepted: 11/12/2012] [Indexed: 01/01/2023] Open
Abstract
Purpose The increasing incidence of small renal tumors in an aging population with comorbidities has stimulated the development of minimally invasive treatments. This study aimed to assess the efficacy and demonstrate feasibility of multimodality imaging of intratumoral administration of holmium-166 microspheres (166HoAcAcMS). This new technique locally ablates renal tumors through high-energy beta particles, while the gamma rays allow for nuclear imaging and the paramagnetism of holmium allows for MRI. Methods 166HoAcAcMS were administered intratumorally in orthotopic renal tumors (Balb/C mice). Post administration CT, SPECT and MRI was performed. At several time points (2 h, 1, 2, 3, 7 and 14 days) after MS administration, tumors were measured and histologically analyzed. Holmium accumulation in organs was measured using inductively coupled plasma mass spectrometry. Results 166HoAcAcMS were successfully administered to tumor bearing mice. A striking near-complete tumor-control was observed in 166HoAcAcMS treated mice (0.10±0.01 cm3 vs. 4.15±0.3 cm3 for control tumors). Focal necrosis and inflammation was present from 24 h following treatment. Renal parenchyma outside the radiated region showed no histological alterations. Post administration CT, MRI and SPECT imaging revealed clear deposits of 166HoAcAcMS in the kidney. Conclusions Intratumorally administered 166HoAcAcMS has great potential as a new local treatment of renal tumors for surgically unfit patients. In addition to strong cancer control, it provides powerful multimodality imaging opportunities.
Collapse
Affiliation(s)
- Wouter Bult
- Imaging Division, Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
- Department of Hospital and Clinical Pharmacy, University Medical Center Groningen, Groningen, The Netherlands
| | - Stephanie G. C. Kroeze
- Department of Urology, University Medical Center Utrecht, Utrecht, The Netherlands
- Laboratory of Experimental Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Mattijs Elschot
- Imaging Division, Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Peter R. Seevinck
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Freek J. Beekman
- Milabs, Utrecht, The Netherlands
- Section Radiation Detection & Medical Imaging, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
| | - Hugo W. A. M. de Jong
- Imaging Division, Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Donald R. A. Uges
- Department of Hospital and Clinical Pharmacy, University Medical Center Groningen, Groningen, The Netherlands
| | - Jos G. W. Kosterink
- Department of Hospital and Clinical Pharmacy, University Medical Center Groningen, Groningen, The Netherlands
| | - Peter R. Luijten
- Imaging Division, Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Wim E. Hennink
- Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands
| | - Alfred D. van het Schip
- Imaging Division, Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - J. L. H. Ruud Bosch
- Department of Urology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - J. Frank W. Nijsen
- Imaging Division, Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
- * E-mail:
| | - Judith J. M. Jans
- Department of Urology, University Medical Center Utrecht, Utrecht, The Netherlands
- Laboratory of Experimental Oncology, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
27
|
Hosseini SH, Enferadi M, Sadeghi M. Dosimetric aspects of 166Ho brachytherapy biodegradable glass seed. Appl Radiat Isot 2012; 73:109-15. [PMID: 23313765 DOI: 10.1016/j.apradiso.2012.12.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2012] [Revised: 10/27/2012] [Accepted: 12/04/2012] [Indexed: 11/20/2022]
Abstract
The purpose of this study is to perform absorbed dose calculations based on Monte Carlo simulations for a novel beta emitter bioglass Ho-166 seed which is proposed for treating small hepatocellular carcinomas (HCCs). The bioactive glass seed has been developed by use of the sol-gel method. Monte Carlo simulations were carried out for the seed using the version 5 of the (MCNP) Monte Carlo radiation transport code to investigate the dosimetric parameters recommended by the AAPM Task Group 60 (TG-60). Dose distributions due to the beta and photon radiation were obtained at different radial distances surrounding the source. The dose rate in water at the reference point was calculated to be 6.71 ± 0.4 cGy h(-1) μCi(-1). The anisotropy function values ranging from 0.745 to 1.928 were obtained for radial distances of 0.3-8 mm and polar angles of 0°-90°. The (166)Ho seed source can deliver high radiation doses to the tumor, while the short range of the beta particles limits damage to the adjacent normal tissue.
Collapse
Affiliation(s)
- S Hamed Hosseini
- Department of Biomedical Radiation Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran.
| | | | | |
Collapse
|
28
|
van de Maat GH, Seevinck PR, Elschot M, Smits MLJ, de Leeuw H, van Het Schip AD, Vente MAD, Zonnenberg BA, de Jong HWAM, Lam MGEH, Viergever MA, van den Bosch MAAJ, Nijsen JFW, Bakker CJG. MRI-based biodistribution assessment of holmium-166 poly(L-lactic acid) microspheres after radioembolisation. Eur Radiol 2012; 23:827-35. [PMID: 23014797 PMCID: PMC3563959 DOI: 10.1007/s00330-012-2648-2] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Revised: 07/20/2012] [Accepted: 08/15/2012] [Indexed: 12/16/2022]
Abstract
Objectives To demonstrate the feasibility of MRI-based assessment of the intrahepatic Ho-PLLA-MS biodistribution after radioembolisation in order to estimate the absorbed radiation dose. Methods Fifteen patients were treated with holmium-166 (166Ho) poly(L-lactic acid)-loaded microspheres (Ho-PLLA-MS, mean 484 mg; range 408–593 mg) in a phase I study. Multi-echo gradient-echo MR images were acquired from which R2* maps were constructed. The amount of Ho-PLLA-MS in the liver was determined by using the relaxivity r2* of the Ho-PLLA-MS and compared with the administered amount. Quantitative single photon emission computed tomography (SPECT) was used for comparison with MRI regarding the whole liver absorbed radiation dose. Results R2* maps visualised the deposition of Ho-PLLA-MS with great detail. The mean total amount of Ho-PLLA-MS detected in the liver based on MRI was 431 mg (range 236–666 mg) or 89 ± 19 % of the delivered amount (correlation coefficient r = 0.7; P < 0.01). A good correlation was found between the whole liver mean absorbed radiation dose as assessed by MRI and SPECT (correlation coefficient r = 0.927; P < 0.001). Conclusion MRI-based dosimetry for holmium-166 radioembolisation is feasible. Biodistribution is visualised with great detail and quantitative measurements are possible. Key Points • Radioembolisation is increasingly used for treating unresectable primary or metastatic liver tumours. • MRI-based intrahepatic microsphere biodistribution assessment is feasible after holmium-166 radioembolisation. • MRI enables quantification of holmium-166 microspheres in liver in a short imaging time. • MRI can estimate the whole liver absorbed radiation dose following holmium-166 radioembolisation.
Collapse
Affiliation(s)
- Gerrit H van de Maat
- Image Sciences Institute, University Medical Center Utrecht, Q S.459, PO Box 85500, 3508 GA Utrecht, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|