1
|
Yashima N, Minamizono W, Matsunaga H, Lyu J, Fujikawa K, Suito H, Okunuki T, Nakai S, Ohsako M. Non-contact electrical stimulation via a Vector-potential transformer promotes bone healing in drill-hole injury model. J Bone Miner Metab 2025:10.1007/s00774-025-01603-0. [PMID: 40301161 DOI: 10.1007/s00774-025-01603-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2025] [Accepted: 04/09/2025] [Indexed: 05/01/2025]
Abstract
INTRODUCTION We investigated the effects of non-contact electrical stimulation via a Vector-potential (VP) transformer, a novel physical therapy device, on bone healing in drill-hole injury models. MATERIALS AND METHODS Six-week-old male Wistar rats, after a one-week acclimation period, were divided into three groups: the control group (CO), the bone injury group (BI), in which a drill-hole injury was created, and the VP stimulation group (VP), which received non-contact electrical stimulation via a VP transformer after bone injury. In the VP group, rats underwent stimulation at 200 kHz for 30 minutes per day, seven days per week. RESULTS The VP group exhibited increased bone formation as early as day 7 post-injury, with significantly higher bone volume than the BI group at all time points (day 7: p = 0.0003; day 14: p = 0.0024; day 21: p = 0.0001). By day 21, the VP group showed lighter toluidine blue staining and reduced biglycan immunoreactivity compared to the BI group. Bone mineral density also increased (p = 0.0008). Osteoblasts in the VP group displayed abundant cytoplasm and a high capacity for osteocalcin synthesis. Additionally, the VP group demonstrated increased expression of Bglap (day 5: p = 0.0068; day 7: p = 0.0096) and Ctsk (day 7: p = 0.0329; day 14: p = 0.0171), along with a higher number of TRAP-positive osteoclasts (day 21: p = 0.0159) compared to the BI group. CONCLUSION Non-contact electrical stimulation via a VP transformer promotes bone healing in drill-hole injury models.
Collapse
Affiliation(s)
- Nao Yashima
- Graduate School of Health and Sports Science, Toyo University, 1-7-11 Akabanedai, Kita-ku, Tokyo, 115-8650, Japan.
| | - Wataru Minamizono
- Graduate School of Human Life Design, Toyo University, 1-7-11 Akabanedai, Kita-ku, Tokyo, 115-8650, Japan
| | - Hiroya Matsunaga
- Graduate School of Health and Sports Science, Toyo University, 1-7-11 Akabanedai, Kita-ku, Tokyo, 115-8650, Japan
| | - Jiazheng Lyu
- Graduate School of Health and Sports Science, Toyo University, 1-7-11 Akabanedai, Kita-ku, Tokyo, 115-8650, Japan
| | - Kaoru Fujikawa
- Department of Oral Anatomy, Showa Medical University School of Dentistry, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo, 142-0064, Japan
| | - Hirai Suito
- Department of Anatomy, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi-ku, Tokyo, 173-8605, Japan
| | - Takumi Okunuki
- Japan Society for the Promotion of Science, Research Organization of Science and Technology, Ritsumeikan University, 5-3-1 Kojimachi, Chiyoda-ku, Tokyo, 102-0083, Japan
| | - Shingo Nakai
- Department of Judo Seifuku and Health Sciences, Tokoha University School of Health Promotional Sciences, 1230 Miyakoda-cho, Hamana-ku, Hamamatsu-shi, Shizuoka, 431-2102, Japan
| | - Masafumi Ohsako
- Department of Health and Sports Science, Toyo University School of Health and Sports Science, 1-7-11 Akabanedai, Kita-ku, Tokyo, 115-8650, Japan
| |
Collapse
|
2
|
Zhao H, Yu F, Wu W. The Mechanism by Which Estrogen Level Affects Knee Osteoarthritis Pain in Perimenopause and Non-Pharmacological Measures. Int J Mol Sci 2025; 26:2391. [PMID: 40141035 PMCID: PMC11942494 DOI: 10.3390/ijms26062391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2025] [Revised: 02/25/2025] [Accepted: 03/03/2025] [Indexed: 03/28/2025] Open
Abstract
Perimenopausal women have fluctuating estrogen levels, which often trigger a range of symptoms of perimenopausal syndromes as estrogen levels decrease. Changes in perimenopausal estrogen levels are closely related to pain in knee osteoarthritis (KOA), which has long been a research area of great interest in perimenopausal women. In recent years, it has been found that perimenopausal estrogen levels have an important role in KOA pain, namely, that estrogen can affect KOA pain through the regulation of inflammatory responses, inhibition of cellular senescence and apoptosis, and modulation of neurotransmitters, which may provide new ideas for KOA treatment. This study aims to describe the mechanism of estrogen level on knee osteoarthritis pain in perimenopause and related non-pharmacological measures, such as physical therapy, physical factor therapy, traditional Chinese medicine, and diet, which can provide a reference for the study and treatment of pain in perimenopausal women with KOA.
Collapse
Affiliation(s)
- Huiying Zhao
- School of Exercise and Health, Shanghai University of Sports, Shanghai 200438, China; (H.Z.); (F.Y.)
| | - Fan Yu
- School of Exercise and Health, Shanghai University of Sports, Shanghai 200438, China; (H.Z.); (F.Y.)
| | - Wei Wu
- School of Athletic Performance, Shanghai University of Sports, Shanghai 200438, China
| |
Collapse
|
3
|
Yamakawa R, Onoe H, Kurashina Y. Hydrogel carrier with bubble vibration enhancer for ultrasound-triggered drug release. ULTRASONICS SONOCHEMISTRY 2025; 112:107173. [PMID: 39612755 PMCID: PMC11635015 DOI: 10.1016/j.ultsonch.2024.107173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Revised: 11/14/2024] [Accepted: 11/21/2024] [Indexed: 12/01/2024]
Abstract
Hydrogel-based drug carriers provide on-demand drug release via external stimuli. Ultrasound is a promising method because of the potential for remotely releasing the drug. However, intense ultrasound irradiation has been required in previous studies. This paper reports drug model release from hydrogel carriers encapsulating bubble vibration enhancers (BVEs) consisting of microbubbles coated with a lipid membrane. Vibration of BVEs induced by ultrasound stimulation promoted the release of drug models with ultrasound irradiation controlled to a biologically safe acoustic pressure based on spatial-peak temporal-average intensity (ISPTA). The release ratio increased significantly from 2.3 % without BVEs and ultrasound to 10.2 % with both. To evaluate the frequency response, the release ratio was measured at three different ultrasound frequencies (0.3, 1.8, and 2.5 MHz), showing increased efficiency as the frequency approached the resonance frequency of the BVEs. For in vivo applications, hydrogel microspherical carriers with BVEs achieved a 12 % release ratio. Poly-L-lysine coating successfully suppressed the drug release to 0.2 %. The carriers demonstrated repeated responsiveness when ultrasound was applied in three 5-minute intervals. The hydrogel carrier encapsulating BVEs we proposed is a promising in vivo device capable of releasing drugs on demand by ultrasound irradiation based on its high biosafety and acoustic responsiveness.
Collapse
Affiliation(s)
- Ryuto Yamakawa
- Division of Advanced Mechanical Systems Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei-shi, Tokyo 184-8588, Japan
| | - Hiroaki Onoe
- Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
| | - Yuta Kurashina
- Division of Advanced Mechanical Systems Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei-shi, Tokyo 184-8588, Japan.
| |
Collapse
|
4
|
Nowicki C, Ganse B. Near-Infrared Spectroscopy Allows for Monitoring of Bone Fracture Healing via Changes in Oxygenation. J Funct Biomater 2024; 15:384. [PMID: 39728184 DOI: 10.3390/jfb15120384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2024] [Revised: 12/06/2024] [Accepted: 12/17/2024] [Indexed: 12/28/2024] Open
Abstract
Bone fractures are associated with hypoxia, but no longitudinal studies of perfusion measurements in human patients have been reported despite the clinical and research potential. In this longitudinal observational cohort study, the near-infrared spectroscopy (NIRS) device PortaMon was used to assess oxy-(O2Hb), deoxy-(HHb) and total (tHb) haemoglobin, as well as the differences between O2Hb and HHb (HbDiff) and the tissue saturation index (TSI) at three different depths in the fracture gap. Linear mixed effect models were fitted to analyse time effects. One-way ANOVAs were conducted to compare groups. The time points corresponding to minima were calculated via linear regression. In this study, 11 patients with tibial shaft fractures underwent longitudinal measurements. Additionally, 9 patients with diagnosed tibial shaft nonunion and 23 age-matched controls were measured once. In the longitudinal group, all fractures healed, and decreases in O2Hb and HbDiff (all p < 0.05) were observed, with minima occurring 19-21 days after fracture. O2Hb values in nonunion patients did not differ from the minima in longitudinally measured union patients, whereas differences in HHb and tHb were significant (all p < 0.05). Previously, the onset of hypoxia has been assumed to be much faster. The characteristic trajectories of the NIRS parameters O2Hb and HbDiff can be used to fulfil the need for a non-invasive method to monitor fracture healing. These results suggest that NIRS could supplement radiographs and clinical impressions in daily clinical practice and may enable earlier diagnosis of nonunion.
Collapse
Affiliation(s)
- Cedric Nowicki
- Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, 66421 Homburg, Germany
| | - Bergita Ganse
- Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, 66421 Homburg, Germany
- Department of Trauma, Hand and Reconstructive Surgery, Departments and Institutes of Surgery, Saarland University, 66421 Homburg, Germany
| |
Collapse
|
5
|
Wu KT, Cheng JH, Jhan SW, Chen PC, Wang CJ, Chou WY. Prognostic factors of extracorporeal shockwave therapy in the treatment of nonunion in long bones: a retrospective study. Int J Surg 2024; 110:6426-6431. [PMID: 38913436 PMCID: PMC11486991 DOI: 10.1097/js9.0000000000001848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Accepted: 06/08/2024] [Indexed: 06/26/2024]
Abstract
BACKGROUND Nonunion of long bone fractures is a significant complication following surgical fixation, with an incidence ranging from 5 to 10%. Surgical intervention is the standard treatment for nonunions, but it may come with potential complications. Nonoperative approaches, such as Extracorporeal Shockwave Therapy (ESWT), have been advocated as alternatives. METHODS In the retrospective study conducted between January 2004 and January 2018, 91 patients who underwent ESWT for tibia or femur nonunions were included. Nonunion was defined based on radiographic criteria and clinical symptoms. The nonunion morphology was categorized as hypertrophic, oligotrophic, or atrophic. ESWT was administered using the OssaTron device in a single treatment session. Bony union was defined as the presence of a bridging callus over the fracture site with more than three-fourths of the circumference in both planes within the 12-month postoperative period. RESULTS The study included 91 patients, with an overall union rate of 62.6%. A higher healing rate was observed in trophic nonunion(69.9%) than in atrophic nonunion(33.3%). Multivariate analysis identified the number of surgeries, maximum fracture gap, and atrophic nonunion as independent factors influencing the risk of fracture nonunion after ESWT. The receiver operating characteristic curves were generated for these factors, providing more than one surgical intervention, and fracture gap greater than 3.94 mm as negative predictors of ESWT for long bone nonunions. CONCLUSION The study's primary findings suggest that ESWT is effective in achieving bony union for nonunions in long bones(62.6%). Despite the overall positive results, the study highlights that atrophic nonunions, larger fracture gaps of more than 3.94 mm, and multiple surgeries are associated with poorer outcomes.
Collapse
Affiliation(s)
- Kuan-Ting Wu
- Center for Shockwave Medicine and Tissue Engineering, Kaohsiung Chang Gung Memorial Hospital
- Department of Orthopedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Graduate Institute of Clinical Medical Science, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Jai-Hong Cheng
- Center for Shockwave Medicine and Tissue Engineering, Kaohsiung Chang Gung Memorial Hospital
- Department of Medical Research, Kaohsiung Chang Gung Memorial Hospital
| | - Shun-Wun Jhan
- Center for Shockwave Medicine and Tissue Engineering, Kaohsiung Chang Gung Memorial Hospital
- Department of Orthopedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Graduate Institute of Clinical Medical Science, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Po-Cheng Chen
- Department of Physical Medicine and Rehabilitation, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
| | - Ching-Jen Wang
- Center for Shockwave Medicine and Tissue Engineering, Kaohsiung Chang Gung Memorial Hospital
- Department of Medical Research, Kaohsiung Chang Gung Memorial Hospital
| | - Wen-Yi Chou
- Center for Shockwave Medicine and Tissue Engineering, Kaohsiung Chang Gung Memorial Hospital
- Department of Medical Research, Kaohsiung Chang Gung Memorial Hospital
| |
Collapse
|
6
|
Li Y, Fan Y, Zhao S, Cheng B. Ultrasound-triggered piezoelectric polyetheretherketone with boosted osteogenesis via regulating Akt/GSK3β/β-catenin pathway. J Nanobiotechnology 2024; 22:539. [PMID: 39237993 PMCID: PMC11375992 DOI: 10.1186/s12951-024-02814-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2024] [Accepted: 08/27/2024] [Indexed: 09/07/2024] Open
Abstract
Maxillofacial bone defects can severely impact quality of life by impairing physiological functions such as chewing, breathing, swallowing, and pronunciation. Polyether ether ketone (PEEK) is commonly used for the repair of maxillofacial defects due to its mechanical adaptability, while its osteogenic properties still need refinement. Herein, we have utilized the piezoelectric effect exhibited by barium titanate (BTO) under low-intensity pulsed ultrasound (LIPUS) to develop an ultrasound responsive PEEK (PDA@BTO-SPEEK, PBSP) through the mediating effect of polydopamine (PDA), for repairing maxillofacial bone defects. After modification by PDA@BTO, PBSP possesses better hydrophilicity, which is conducive to cell growth and adhesion. Simultaneously, by virtue of the piezoelectric characteristics of BTO, PBSP obtains a piezoelectric coefficient that matches the bone cortex. Notably, when PBSP is stimulated by LIPUS, it can generate stable electricity and effectively accelerate the osteogenic differentiation of osteoblasts through the regulation of the Piezo1-induced calcium (Ca2+) influx and Akt/GSK3β/β-catenin pathway. In addition, PBSP presents satisfactory therapeutic effects in rat skull defect models, and its osteogenic efficiency can be further improved under LIPUS stimulation with high tissue penetration. Collectively, PBSP + LIPUS exhibits great potential as a promising alternative strategy for the repair of maxillofacial bone defects.
Collapse
Affiliation(s)
- Yue Li
- Department of Stomatology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430071, China
| | - Yingying Fan
- Department of Stomatology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430071, China
| | - Siyu Zhao
- Department of Stomatology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430071, China.
| | - Bo Cheng
- Department of Stomatology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430071, China.
| |
Collapse
|
7
|
Yuan X, Zhu W, Yang Z, He N, Chen F, Han X, Zhou K. Recent Advances in 3D Printing of Smart Scaffolds for Bone Tissue Engineering and Regeneration. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2403641. [PMID: 38861754 DOI: 10.1002/adma.202403641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 05/15/2024] [Indexed: 06/13/2024]
Abstract
The repair and functional reconstruction of bone defects resulting from severe trauma, surgical resection, degenerative disease, and congenital malformation pose significant clinical challenges. Bone tissue engineering (BTE) holds immense potential in treating these severe bone defects, without incurring prevalent complications associated with conventional autologous or allogeneic bone grafts. 3D printing technology enables control over architectural structures at multiple length scales and has been extensively employed to process biomimetic scaffolds for BTE. In contrast to inert and functional bone grafts, next-generation smart scaffolds possess a remarkable ability to mimic the dynamic nature of native extracellular matrix (ECM), thereby facilitating bone repair and regeneration. Additionally, they can generate tailored and controllable therapeutic effects, such as antibacterial or antitumor properties, in response to exogenous and/or endogenous stimuli. This review provides a comprehensive assessment of the progress of 3D-printed smart scaffolds for BTE applications. It begins with an introduction to bone physiology, followed by an overview of 3D printing technologies utilized for smart scaffolds. Notable advances in various stimuli-responsive strategies, therapeutic efficacy, and applications of 3D-printed smart scaffolds are discussed. Finally, the review highlights the existing challenges in the development and clinical implementation of smart scaffolds, as well as emerging technologies in this field.
Collapse
Affiliation(s)
- Xun Yuan
- National Engineering Research Centre for High Efficiency Grinding, College of Mechanical and Vehicle Engineering, Hunan University, Changsha, 410082, China
| | - Wei Zhu
- National Engineering Research Centre for High Efficiency Grinding, College of Mechanical and Vehicle Engineering, Hunan University, Changsha, 410082, China
| | - Zhongyuan Yang
- National Engineering Research Centre for High Efficiency Grinding, College of Mechanical and Vehicle Engineering, Hunan University, Changsha, 410082, China
| | - Ning He
- National Engineering Research Centre for High Efficiency Grinding, College of Mechanical and Vehicle Engineering, Hunan University, Changsha, 410082, China
| | - Feng Chen
- National Engineering Research Centre for High Efficiency Grinding, College of Mechanical and Vehicle Engineering, Hunan University, Changsha, 410082, China
| | - Xiaoxiao Han
- National Engineering Research Centre for High Efficiency Grinding, College of Mechanical and Vehicle Engineering, Hunan University, Changsha, 410082, China
| | - Kun Zhou
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| |
Collapse
|
8
|
Kim D, Lee MJ, Arai Y, Ahn J, Lee GW, Lee SH. Ultrasound-triggered three dimensional hyaluronic acid hydrogel promotes in vitro and in vivo reprogramming into induced pluripotent stem cells. Bioact Mater 2024; 38:331-345. [PMID: 38764447 PMCID: PMC11101682 DOI: 10.1016/j.bioactmat.2024.05.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 04/12/2024] [Accepted: 05/05/2024] [Indexed: 05/21/2024] Open
Abstract
Cellular reprogramming technologies have been developed with different physicochemical factors to improve the reprogramming efficiencies of induced pluripotent stem cells (iPSCs). Ultrasound is a clinically applied noncontact biophysical factor known for regulating various cellular behaviors but remains uninvestigated for cellular reprogramming. Here, we present a new reprogramming strategy using low-intensity ultrasound (LIUS) to improve cellular reprogramming of iPSCs in vitro and in vivo. Under 3D microenvironment conditions, increased LIUS stimulation shows enhanced cellular reprogramming of the iPSCs. The cellular reprogramming process facilitated by LIUS is accompanied by increased mesenchymal to epithelial transition and histone modification. LIUS stimulation transiently modulates the cytoskeletal rearrangement, along with increased membrane fluidity and mobility to increase HA/CD44 interactions. Furthermore, LIUS stimulation with HA hydrogel can be utilized in application of both human cells and in vivo environment, for enhanced reprogrammed cells into iPSCs. Thus, LIUS stimulation with a combinatorial 3D microenvironment system can improve cellular reprogramming in vitro and in vivo environments, which can be applied in various biomedical fields.
Collapse
Affiliation(s)
| | | | - Yoshie Arai
- Department of Biomedical Engineering, Dongguk University-Seoul, 04620, Seoul, South Korea
| | - Jinsung Ahn
- Department of Biomedical Engineering, Dongguk University-Seoul, 04620, Seoul, South Korea
| | - Gun Woo Lee
- Department of Biomedical Engineering, Dongguk University-Seoul, 04620, Seoul, South Korea
| | - Soo-Hong Lee
- Department of Biomedical Engineering, Dongguk University-Seoul, 04620, Seoul, South Korea
| |
Collapse
|
9
|
Li P, Zhang Z, Liu J, Xue H. LIPUS can promote osteogenesis of hPDLCs and inhibit the periodontal inflammatory response via TLR5. Oral Dis 2024; 30:3386-3399. [PMID: 37983889 DOI: 10.1111/odi.14807] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 09/26/2023] [Accepted: 11/02/2023] [Indexed: 11/22/2023]
Abstract
In this study, we isolated human periodontal ligament cells (hPDLCs) to find the optimal time of LIPUS stimulation and to explore how LIPUS affects inflammatory and osteogenic responses in hPDLCs in an inflammatory environment. The target molecules of LIPUS were identified by high-throughput sequencing. RT-qPCR and WB were used to detect how LIPUS affected the expression of related genes in TNFα-induced inflammation. The expression of ROS and inflammatory factors was detected by flow cytometry. Immunohistochemistry was used to further verify gene expression in rats. hPDLCs were isolated successfully. The optimal LIPUS stimulation condition was 45 mW/cm2 for 30 min and continued for 3 days, and this intensity significantly promoted the osteogenesis and mineralization of hPDLCs. LIPUS significantly inhibited the upregulation of IL-6 and ROS, increased the percentage of cells in the G2 phase, inhibited cell apoptosis, and inhibited the upregulation of TLR5 expression in an inflammatory environment. LIPUS can effectively restrain the inflammation and oxidative stress response of hPDLCs and promote osteogenesis in an inflammatory environment. LIPUS inhibited the periodontal inflammatory response through TLR5 in hPDLCs and dental pulp.
Collapse
Affiliation(s)
- Ping Li
- Departments of Stomatology and Central Lab, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, China
| | - Zhipeng Zhang
- Departments of Stomatology and Central Lab, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, China
| | - Jingjing Liu
- Department of Stomatology, The Dushu Lake Hospital Affiliated to Soochow University, Suzhou, Jiangsu, China
| | - Hui Xue
- Departments of Stomatology and Central Lab, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, China
| |
Collapse
|
10
|
Wang Y, Cao X, Shen Y, Zhong Q, Huang Y, Zhang Y, Huang Q, Xu C. Osteogenic effect of low-intensity pulsed ultrasound on peri-implant bone: A systematic review and meta-analysis. J Prosthodont Res 2024; 68:215-226. [PMID: 37518333 DOI: 10.2186/jpr.jpr_d_23_00068] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
Purpose This study aimed to evaluate the effect of low-intensity pulsed ultrasound (LIPUS) on promoting osseointegration around dental implants.Study selection A comprehensive search was performed on two databases, including MEDLINE (PubMed) and Web of Science to identify relevant studies published before June 1, 2022. Randomized controlled trials that met the inclusion criteria were selected for the study. The year of publication, study design, animal species, number of animals, number of implants, implant position, implant size, intervention, follow-up time, bone volume ratio (BV/TV), bone-implant contact ratio (BIC), and implant removal torque value (RTV) measurements, including mean and SD, were extracted.Results Ten randomized trials were included in this meta-analysis. The results showed that LIPUS significantly promoted osteogenesis around dental implants. Furthermore, in animal models of pre-existing diseases such as osteoporosis and diabetes, LIPUS had the same effect. The included data were divided into subgroups to explore the effects of different follow-up time, acoustic intensities, and frequencies. Results showed that higher acoustic intensities and frequencies significantly improve the osteogenic effects of LIPUS. There was some degree of heterogeneity owing to bias in the included studies. More high-quality randomized controlled trials are necessary in the future.Conclusions LIPUS can promote bone healing around dental implants and is an attractive option for edentulous patients, especially those with pre-existing diseases. Further clinical trials on the use of LIPUS in implant dentistry are warranted. Furthermore, future studies must pay more attention to acoustic intensity and frequency.
Collapse
Affiliation(s)
- Yingying Wang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Ximeng Cao
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yingyi Shen
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Qi Zhong
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yujie Huang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yifan Zhang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Qingfeng Huang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Chun Xu
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| |
Collapse
|
11
|
Hall TAG, Theodoridis K, Kohli N, Cegla F, van Arkel RJ. Active osseointegration in an ex vivo porcine bone model. Front Bioeng Biotechnol 2024; 12:1360669. [PMID: 38585711 PMCID: PMC10995341 DOI: 10.3389/fbioe.2024.1360669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 03/08/2024] [Indexed: 04/09/2024] Open
Abstract
Achieving osseointegration is a fundamental requirement for many orthopaedic, oral, and craniofacial implants. Osseointegration typically takes three to 6 months, during which time implants are at risk of loosening. The aim of this study was to investigate whether osseointegration could be actively enhanced by delivering controllable electromechanical stimuli to the periprosthetic bone. First, the osteoconductivity of the implant surface was confirmed using an in vitro culture with murine preosteoblasts. The effects of active treatment on osseointegration were then investigated in a 21-day ex vivo model with freshly harvested cancellous bone cylinders (n = 24; Ø10 mm × 5 mm) from distal porcine femora, with comparisons to specimens treated by a distant ultrasound source and static controls. Cell viability, proliferation and distribution was evident throughout culture. Superior ongrowth of tissue onto the titanium discs during culture was observed in the actively stimulated specimens, with evidence of ten-times increased mineralisation after 7 and 14 days of culture (p < 0.05) and 2.5 times increased expression of osteopontin (p < 0.005), an adhesive protein, at 21 days. Moreover, histological analyses revealed increased bone remodelling at the implant-bone interface in the actively stimulated specimens compared to the passive controls. Active osseointegration is an exciting new approach for accelerating bone growth into and around implants.
Collapse
Affiliation(s)
- Thomas A G Hall
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Konstantinos Theodoridis
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Nupur Kohli
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Frederic Cegla
- Non-Destructive Evaluation Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Richard J van Arkel
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| |
Collapse
|
12
|
Pan C, Lu F, Hao X, Deng X, Liu J, Sun K, Hou W, Shang X, Chi R, Guo F, Xu T. Low-intensity pulsed ultrasound delays the progression of osteoarthritis by regulating the YAP-RIPK1-NF-κB axis and influencing autophagy. J Transl Med 2024; 22:286. [PMID: 38493143 PMCID: PMC10943805 DOI: 10.1186/s12967-024-05086-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 03/10/2024] [Indexed: 03/18/2024] Open
Abstract
BACKGROUND Osteoarthritis (OA) is a degenerative disease characterized by chronic inflammation of the joint. As the disease progresses, patients will gradually develop symptoms such as pain, physical limitations and even disability. The risk factors for OA include genetics, gender, trauma, obesity, and age. Unfortunately, due to limited understanding of its pathological mechanism, there are currently no effective drugs or treatments to suspend the progression of osteoarthritis. In recent years, some studies found that low-intensity pulsed ultrasound (LIPUS) may have a positive effect on osteoarthritis. Nonetheless, the exact mechanism by which LIPUS affects osteoarthritis remains unknown. It is valuable to explore the specific mechanism of LIPUS in the treatment of OA. METHODS In this study, we validated the potential therapeutic effect of LIPUS on osteoarthritis by regulating the YAP-RIPK1-NF-κB axis at both cellular and animal levels. To verify the effect of YAP on OA, the expression of YAP was knocked down or overexpressed by siRNA and plasmid in chondrocytes and adeno-associated virus was injected into the knee joint of rats. The effect of LIPUS was investigated in inflammation chondrocytes induced by IL-1β and in the post-traumatic OA model. RESULTS In this study, we observed that YAP plays an important role in the development of osteoarthritis and knocking down of YAP significantly inhibited the inflammation and alleviated cartilage degeneration. We also demonstrated that the expression of YAP was increased in osteoarthritis chondrocytes and YAP could interact with RIPK1, thereby regulating the NF-κB signal pathway and influencing inflammation. Moreover, we also discovered that LIPUS decreased the expression of YAP by restoring the impaired autophagy capacity and inhibiting the binding between YAP and RIPK1, thereby delaying the progression of osteoarthritis. Animal experiment showed that LIPUS could inhibit cartilage degeneration and alleviate the progression of OA. CONCLUSIONS These results showed that LIPUS is effective in inhibiting inflammation and cartilage degeneration and alleviate the progression of OA. As a result, our results provide new insight of mechanism by which LIPUS delays the development of osteoarthritis, offering a novel therapeutic regimen for osteoarthritis.
Collapse
Affiliation(s)
- Chunran Pan
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Fan Lu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Xiaoxia Hao
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Xiaofeng Deng
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Jiawei Liu
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Kai Sun
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Wenjie Hou
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Xingru Shang
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Ruimin Chi
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China
| | - Fengjing Guo
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China.
| | - Tao Xu
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095#, Jie-Fang Avenue, Qiaokou District, Wuhan, 430030, Hubei, China.
| |
Collapse
|
13
|
Nakagawa T, Inui T, Matsui K, Ishii K, Suzuki T, Kurozumi T, Kawano H, Watanabe Y. Effect of postoperative fracture gap on bone union: A retrospective cohort analysis of simple femoral shaft fractures. J Orthop Sci 2024; 29:632-636. [PMID: 36914485 DOI: 10.1016/j.jos.2023.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 02/14/2023] [Accepted: 02/17/2023] [Indexed: 03/16/2023]
Abstract
BACKGROUND Intramedullary nailing (IMN) is considered the gold-standard treatment for femoral shaft fractures. The post operative fracture gap is commonly recognized as a risk factor for nonunion. However, no evaluation standard for measuring the fracture gap size has yet been established. In addition, the clinical implications of the fracture gap size have also not been determined so far. This study aims to clarify how we should evaluate fracture gaps when assessing simple femoral shaft fractures with radiographs and to determine the acceptable cut-off value of the fracture gap size in simple femoral shaft fractures. METHOD A retrospective observational study with a consecutive cohort was conducted at the trauma center of a university hospital. We investigated the fracture gap using postoperative radiography and the postoperative bone union of transverse and short oblique femoral shaft fractures fixed by IMN. The receiver operating characteristic curve analysis was conducted to obtain the fracture gap's mean, minimum, and maximum cut-off values. Fisher's exact test was used at the cut-off value of the most accurate parameter. RESULTS In the four nonunions among the 30 cases, the analysis using ROC curves revealed that the maximum value had the highest accuracy among the maximum, minimum, and mean values of fracture-gap size. The cut-off value was determined to be 4.14 mm with high accuracy. Fisher's exact test showed that the incidence of nonunion was higher in the group with a maximum fracture gap of 4.14 mm or greater (risk ratio = not applicable, risk difference = 0.57, P = 0.001). CONCLUSION In simple transverse and short oblique femoral shaft fractures fixed with IMN, the fracture gap on radiographs should be evaluated by the maximum gap in the AP and lateral views. The remaining maximum fracture gap of ≥4.14 mm would be a risk factor for nonunion.
Collapse
Affiliation(s)
- Tomoo Nakagawa
- Trauma and Reconstruction Center, Teikyo University Hospital, 2-11-1 Kaga, Itabashi, Tokyo, Japan; Department of Orthopaedic Surgery, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi, Tokyo, Japan.
| | - Takahiro Inui
- Trauma and Reconstruction Center, Teikyo University Hospital, 2-11-1 Kaga, Itabashi, Tokyo, Japan; Department of Orthopaedic Surgery, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi, Tokyo, Japan
| | - Kentaro Matsui
- Trauma and Reconstruction Center, Teikyo University Hospital, 2-11-1 Kaga, Itabashi, Tokyo, Japan; Department of Orthopaedic Surgery, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi, Tokyo, Japan
| | - Keisuke Ishii
- Trauma and Reconstruction Center, Teikyo University Hospital, 2-11-1 Kaga, Itabashi, Tokyo, Japan
| | - Takashi Suzuki
- Trauma and Reconstruction Center, Teikyo University Hospital, 2-11-1 Kaga, Itabashi, Tokyo, Japan
| | - Taketo Kurozumi
- Trauma and Reconstruction Center, Teikyo University Hospital, 2-11-1 Kaga, Itabashi, Tokyo, Japan
| | - Hirotaka Kawano
- Department of Orthopaedic Surgery, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi, Tokyo, Japan
| | - Yoshinobu Watanabe
- Trauma and Reconstruction Center, Teikyo University Hospital, 2-11-1 Kaga, Itabashi, Tokyo, Japan; Department of Orthopaedic Surgery, Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi, Tokyo, Japan
| |
Collapse
|
14
|
Higdon JR, Spooner WL, Kang J. Ultrasound-dependent kinetics of bone mineralization. Bone 2024; 180:116999. [PMID: 38158169 DOI: 10.1016/j.bone.2023.116999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 12/25/2023] [Indexed: 01/03/2024]
Abstract
Bone Mineral Density (BMD) is an important parameter in the development of orthopedic fracture-healing methods. A recent article (Inoue, S., et al. Bone. 2023, 177, 116916) investigated the use of higher intensity ultrasound to promote murine bone formation by measuring BMD levels. In this work, we present the numerical values of BMD, which show sigmoid kinetics and hyperbolic asymptotic increase with the application of higher intensity ultrasound. Our analysis may provide a foundation for the understanding and application of ultrasound to the human body.
Collapse
Affiliation(s)
- Julia R Higdon
- Department of Biology, Valdosta State University, Valdosta, GA 31698, USA
| | - William L Spooner
- Department of Applied Mathematics and Physics, Valdosta State University, Valdosta, GA 31698, USA
| | - Jonghoon Kang
- Department of Biology, Valdosta State University, Valdosta, GA 31698, USA.
| |
Collapse
|
15
|
Han L, Zhao C, Zhu Y, Li H. Dimethyloxallyl glycine-loaded mesoporous bioactive glass/poly(D,L-lactide) composite scaffolds with ultrasound stimulation for promoting bone repair. Front Bioeng Biotechnol 2024; 12:1339135. [PMID: 38476968 PMCID: PMC10928532 DOI: 10.3389/fbioe.2024.1339135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 02/08/2024] [Indexed: 03/14/2024] Open
Abstract
Introduction: Bone tissue engineering is considered the ideal approach for bone repair. Mesoporous bioactive glass (MBG) possesses the characteristics of high drug-loading capacity and bioactivity. Low-intensity pulsed ultrasound contributes to promoting fracture healing and bone defect repair, and dimethyloxalyl glycine (DMOG) is a small molecular inhibitor that can suppress prolyl hydroxylase, reducing the degradation of hypoxia-inducible factor. Methods: In this study, we proposed to prepare DMOG-loaded MBG/poly(D,L-lactide) composite scaffolds (DMOG-MBG/PDLLA) for promoting bone repair. The effects of ultrasound stimulation and DMOG release on the cell responses of rat bone marrow mesenchymal stem cells (BMSCs) and human umbilical vein endothelial cells (HUVECs) and bone repair in vivo were investigated. Results and Discussion: The results showed that both ultrasound stimulation and DMOG release could promote the proliferation, adhesion and differentiation of BMSCs and HUVECs, respectively. After the implantation of scaffolds in rat cranial bone defect model for 8 weeks, the results indicated that the combined ultrasound stimulation and DMOG release contributed to the highest ability for promoting bone repair. Hence, the DMOG-MBG/PDLLA scaffolds with ultrasound stimulation are promising for application in bone repair.
Collapse
Affiliation(s)
- Lei Han
- Department of Orthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China
| | - Chaoqian Zhao
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai, China
| | - Yufang Zhu
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Huang Li
- Department of Orthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China
| |
Collapse
|
16
|
Wang Y, Cao X, Shen Y, Zhong Q, Wu Z, Wu Y, Weng W, Xu C. Evaluate the effects of low-intensity pulsed ultrasound on dental implant osseointegration under type II diabetes. Front Bioeng Biotechnol 2024; 12:1356412. [PMID: 38371421 PMCID: PMC10869464 DOI: 10.3389/fbioe.2024.1356412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 01/19/2024] [Indexed: 02/20/2024] Open
Abstract
Objective: The objective of this study is to assess the impact of low-intensity pulsed ultrasound (LIPUS) therapy on the peri-implant osteogenesis in a Type II diabetes mellitus (T2DM) rat model. Methods: A total of twenty male Sprague-Dawley (SD) rats were randomly allocated into four groups: Control group, T2DM group, Control-LIPUS group, and T2DM-LIPUS group. Implants were placed at the rats' bilateral maxillary first molar sites. The LIPUS treatment was carried out on the rats in Control-LIPUS group and T2DM-LIPUS group, immediately after the placement of the implants, over three consecutive weeks. Three weeks after implantation, the rats' maxillae were extracted for micro-CT, removal torque value (RTV), and histologic analysis. Results: Micro-CT analysis showed that T2DM rats experienced more bone loss around implant cervical margins compared with the non-T2DM rats, while the LIPUS treated T2DM rats showed similar bone heights to the non-T2DM rats. Bone-implant contact ratio (BIC) were lower in T2DM rats but significantly improved in the LIPUS treated T2DM rats. Bone formation parameters including bone volume fraction (BV/TV), trabecular thickness (Tb.Th), bone mineral density (BMD) and RTV were all positively influenced by LIPUS treatment. Histological staining further confirmed LIPUS's positive effects on peri-implant new bone formation in T2DM rats. Conclusion: As an effective and safe treatment in promoting osteogenesis, LIPUS has a great potential for T2DM patients to attain improved peri-implant osteogenesis. To confirm its clinical efficacy and to explore the underlying mechanism, further prospective cohort studies or randomized controlled trials are needed in the future.
Collapse
Affiliation(s)
- Yingying Wang
- Department of Prosthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China
| | - Ximeng Cao
- Department of Prosthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yingyi Shen
- Department of Prosthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China
| | - Qi Zhong
- Department of Prosthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China
| | - Ziang Wu
- Department of Prosthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yaqin Wu
- Department of Prosthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China
| | - Weimin Weng
- Department of Prosthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China
| | - Chun Xu
- Department of Prosthodontics, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, China
| |
Collapse
|
17
|
Zhang L, Du W, Kim JH, Yu CC, Dagdeviren C. An Emerging Era: Conformable Ultrasound Electronics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307664. [PMID: 37792426 DOI: 10.1002/adma.202307664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 09/19/2023] [Indexed: 10/05/2023]
Abstract
Conformable electronics are regarded as the next generation of personal healthcare monitoring and remote diagnosis devices. In recent years, piezoelectric-based conformable ultrasound electronics (cUSE) have been intensively studied due to their unique capabilities, including nonradiative monitoring, soft tissue imaging, deep signal decoding, wireless power transfer, portability, and compatibility. This review provides a comprehensive understanding of cUSE for use in biomedical and healthcare monitoring systems and a summary of their recent advancements. Following an introduction to the fundamentals of piezoelectrics and ultrasound transducers, the critical parameters for transducer design are discussed. Next, five types of cUSE with their advantages and limitations are highlighted, and the fabrication of cUSE using advanced technologies is discussed. In addition, the working function, acoustic performance, and accomplishments in various applications are thoroughly summarized. It is noted that application considerations must be given to the tradeoffs between material selection, manufacturing processes, acoustic performance, mechanical integrity, and the entire integrated system. Finally, current challenges and directions for the development of cUSE are highlighted, and research flow is provided as the roadmap for future research. In conclusion, these advances in the fields of piezoelectric materials, ultrasound transducers, and conformable electronics spark an emerging era of biomedicine and personal healthcare.
Collapse
Affiliation(s)
- Lin Zhang
- Media Lab, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Wenya Du
- Media Lab, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Jin-Hoon Kim
- Media Lab, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Chia-Chen Yu
- Media Lab, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Canan Dagdeviren
- Media Lab, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| |
Collapse
|
18
|
Zhang X, Gao W, Zhou J, Dai H, Xiang X, Xu J. Low-intensity pulsed ultrasound in the treatment of masticatory myositis and temporomandibular joint synovitis: A clinical trial. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2024; 125:101632. [PMID: 37703917 DOI: 10.1016/j.jormas.2023.101632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/06/2023] [Accepted: 09/10/2023] [Indexed: 09/15/2023]
Abstract
BACKGROUND Low-intensity pulsed ultrasound (LIPUS) is a non-invasive physical stimulation application for the therapy of articular cartilage injury. This study aimed to explore the therapeutic effects of low-intensity pulsed ultrasound in treating masticatory myositis and synovitis in temporomandibular joint disorders and to establish an evaluation system to evaluate the clinical efficacy. METHODS TMD patients who met the inclusion criteria in the temporomandibular joint clinic of the affiliated Stomatological Hospital of Chongqing Medical University from April 3, 2021, to December 2021 were selected. Before the start and after 7 days of LIPUS treatment, the Fricton temporomandibular joint disorder index, Visual Analog Scale (VAS), and Pressure Difference of Precision Manometer (PD) were measured. A paired t-test was used to compare the values of the Fricton index, VAS, and PD before and after treatment in each group. One-way ANOVA analysis of variance was used to compare the differences between groups. RESULTS After one week of LIPUS treatment, the PI, DI and CMI of the Fricton index in the masticatory myositis (PI: P < 0.001; CMI: P < 0.001; DI: P = 0.2641, ns) and the synovitis group (DI: P < 0.001; CMI: P < 0.001, PI: P = 0.9729, ns) significantly decreased. The VAS of the masticatory myositis group and the synovitis group were significantly reduced (P < 0.001). The PD between the affected and healthy sides of the masticatory myositis group and the synovitis group was significantly reduced (P < 0.001), and the reduction was more evident in the M group. CONCLUSIONS LIPUS is effective in pain relief in patients with masticatory myositis and joint synovitis, meanwhile, masticatory myositis was more sensitive to LIPUS. A new comprehensive clinical efficacy evaluation system which includes PV, FI, and VAS was created to better 2 diagnose masticatory myositis and joint synovitis.
Collapse
Affiliation(s)
- Xiaoqing Zhang
- Stomatological Hospital of Chongqing Medical University, No. 426 Songshi North Road, Chongqing, China; Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Wentong Gao
- Stomatological Hospital of Chongqing Medical University, No. 426 Songshi North Road, Chongqing, China; Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Jianping Zhou
- Stomatological Hospital of Chongqing Medical University, No. 426 Songshi North Road, Chongqing, China; Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Hongwei Dai
- Stomatological Hospital of Chongqing Medical University, No. 426 Songshi North Road, Chongqing, China; Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Xuerong Xiang
- Stomatological Hospital of Chongqing Medical University, No. 426 Songshi North Road, Chongqing, China; Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China.
| | - Jie Xu
- Stomatological Hospital of Chongqing Medical University, No. 426 Songshi North Road, Chongqing, China; Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China.
| |
Collapse
|
19
|
Yang H, Hu Y, Kong B, Zhou Y, Shuai W. Low-intensity pulsed ultrasound treatment mitigates ventricular arrhythmias via inhibiting microglia-mediated neuroinflammation in heart failure rat model. Int Immunopharmacol 2024; 126:111317. [PMID: 38048669 DOI: 10.1016/j.intimp.2023.111317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 11/11/2023] [Accepted: 11/27/2023] [Indexed: 12/06/2023]
Abstract
BACKGROUND Sympathetic overactivation plays an important role in heart failure (HF)-induced ventricular arrhythmias (VAs). Microglia-mediated neuroinflammation could contribute to sympathetic overactivation. A previous study demonstrated that low-intensity pulsed ultrasound (LIPUS) could inhibit neuroinflammation. However, whether LIPUS could attenuate HF-induced VAs via inhibiting microglia-mediated neuroinflammation remains largely unknown. METHODS Forth Sprague-Dawley male rats were averagely randomized into four groups: CTL (control) group, CTL + LIPUS group, HF group and HF + LIPUS. Surgical ligation of the coronary artery was used for induction of HF. In vivo electrophysiological study was performed to check VAs susceptibility. Left stellate ganglion (LSG) neural activity and heart rate variability (HRV) were used to test sympathetic nerve activity. RESULTS Compared to the HF group, LIPUS treatment significantly ameliorated HF-induced cardiac hypertrophy, fibrosis, and dysfunction. In addition, LIPUS treatment markedly inhibited HF-induced VAs susceptibility and reversed gap junction remodeling. LIPUS treatment obviously inhibited microglial activation and neuroinflammation in PVN, sympathetic hyperactivity in the LSG and proinflammatory cytokines releases in the ventricle. P2X7/NLRP3 signaling pathway may be involved in the anti-arrhythmic effect of LIPUS treatment following HF. CONCLUSIONS Our data demonstrated that LIPUS treatment protected against HF-induced VAs via alleviating microglia-mediated neuroinflammation, sympathetic overactivation and proinflammatory cytokines releases through inhibiting P2X7/NLRP3 signaling. This study provides novel insight into the therapeutic potential of LIPUS.
Collapse
Affiliation(s)
- Hongjie Yang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, PR China
| | - Yugang Hu
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, PR China
| | - Bin Kong
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, PR China
| | - Yanxiang Zhou
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, PR China.
| | - Wei Shuai
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, PR China.
| |
Collapse
|
20
|
Kojima Y, Watanabe T. Low-intensity pulsed ultrasound irradiation attenuates collagen degradation of articular cartilage in early osteoarthritis-like model mice. J Exp Orthop 2023; 10:106. [PMID: 37870591 PMCID: PMC10593698 DOI: 10.1186/s40634-023-00672-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 10/11/2023] [Indexed: 10/24/2023] Open
Abstract
PURPOSE Osteoarthritis (OA) is a combination of degeneration and destruction of articular cartilage due to mechanical stress, secondary synovitis, and bone remodelling. In recent years, early knee OA, a preliminary stage of structural failure in OA, has attracted attention as a potential target for therapy to prevent the onset of OA. Intra-articular administration of monoiodoacetic acid (MIA) induces OA-like symptoms, and low doses of MIA induce early OA like symptoms. In this experiment, a low-dose of MIA was induced to early OA model mice, which were then irradiated with low-intensity pulsed ultrasound (LIPUS) to examine whether LIPUS improves symptoms of early OA. METHODS After 4 weeks of LIPUS irradiation, articular cartilage was observed at 1 and 4 weeks. The Osteoarthritis Research Society International (OARSI) scores were calculated using Safranin-O staining results. Cartilage degeneration was detected using Denatured Collagen Detection Reagent (DCDR). RESULTS We observed a significant decrease in OARSI scores in the LIPUS irradiated group at week 4. The non-LIPUS group showed widespread areas of double positivity for Type II collagen and DCDR, whereas the LIPUS group showed only a small number of DCDR-positive areas. In addition, macrophage numbers counted in the articular capsule at week 1 showed a significant decrease in the LIPUS irradiated group. Lubricin detection showed that lubricin positive cell number was significantly increased by LIPUS irradiation at week 4. CONCLUSIONS These results suggest that LIPUS attenuates cartilage degeneration in early OA by relieving inflammation and enhancing the inhibitory effect of lubricin on cartilage degeneration.
Collapse
Affiliation(s)
- Yoshitsugu Kojima
- Clinical Pharmacology Research Laboratory, Yokohama University of Pharmacy, 601 Matanocho Totsukaku, Yokohama, Kanagawa, 245-0066, Japan.
- Planning and Product Development Division, Nippon Sigmax Co., Ltd., 7th Floor, 1-24-1 Nishi-shinjuku, Shinjuku-Ku, Tokyo, 160-0023, Japan.
| | - Takayuki Watanabe
- Clinical Pharmacology Research Laboratory, Yokohama University of Pharmacy, 601 Matanocho Totsukaku, Yokohama, Kanagawa, 245-0066, Japan
- Planning and Product Development Division, Nippon Sigmax Co., Ltd., 7th Floor, 1-24-1 Nishi-shinjuku, Shinjuku-Ku, Tokyo, 160-0023, Japan
| |
Collapse
|
21
|
Chu G, Niu H. Knowledge mapping and global trends in the field of low-intensity pulsed ultrasound and endocrine and metabolic diseases: a bibliometric and visual analysis from 2012 to 2022. Front Endocrinol (Lausanne) 2023; 14:1237864. [PMID: 37732128 PMCID: PMC10508976 DOI: 10.3389/fendo.2023.1237864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 08/21/2023] [Indexed: 09/22/2023] Open
Abstract
Background Low-intensity pulsed ultrasound (LIPUS) is a highly promising therapeutic method that has been widely used in rehabilitation, orthopedics, dentistry, urology, gynecology, and other multidisciplinary disease diagnoses and treatments. It has attracted extensive attention worldwide. However, there is currently a lack of comprehensive and systematic research on the current status and future development direction of the LIPUS field. Therefore, this study comprehensively analyzed LIPUS-related reports from the past decade using bibliometrics methods, and further conducted research specifically focusing on its application in endocrine and metabolic diseases. Methods We downloaded LIPUS literature from 2012 to 2022 reported in the Web of Science Core Collection Science Citation Index-Expanded and Social Sciences Citation Index, and used bibliometric analysis software such as VOSviewer and CiteSpace to execute the analysis and visualize the results. Results We searched for 655 English articles published on LIPUS from 2012 to 2022. China had the highest number of published articles and collaborations between China and the United States were the closest in this field. Chongqing Medical University was the institution with the highest output, and ULTRASOUND IN MEDICINE AND BIOLOGY was the journal with the most related publications. In recent years, research on the molecular mechanisms of LIPUS has continued to deepen, and its clinical applications have also continued to expand. The application of LIPUS in major diseases such as oxidative stress, regeneration mechanism, and cancer is considered to be a future research direction, especially in the field of endocrinology and metabolism, where it has broad application value. Conclusion Global research on LIPUS is expected to continue to increase, and future research will focus on its mechanisms of action and clinical applications. This study comprehensively summarizes the current development status and global trends in the field of LIPUS, and its research progress in the field of endocrine and metabolic diseases, providing valuable reference for future research in this field.
Collapse
Affiliation(s)
| | - Haitao Niu
- Department of Urology, The Affiliated Hospital of Qingdao University, Qingdao, China
| |
Collapse
|
22
|
Wang W, Zhong Y, Zhou Y, Yu Y, Li J, Kang S, Ma Z, Fan X, Sun L, Tang L. Low-intensity pulsed ultrasound mitigates cognitive impairment by inhibiting muscle atrophy in hindlimb unloaded mice. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:1427-1438. [PMID: 37672304 DOI: 10.1121/10.0020835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 08/14/2023] [Indexed: 09/07/2023]
Abstract
Microgravity leads to muscle loss, usually accompanied by cognitive impairment. Muscle reduction was associated with the decline of cognitive ability. Our previous studies showed that low-intensity pulsed ultrasound (LIPUS) promoted muscle hypertrophy and prevented muscle atrophy. This study aims to verify whether LIPUS can improve cognitive impairment by preventing muscle atrophy in hindlimb unloaded mice. In this study, mice were randomly divided into normal control (NC), hindlimb unloading (HU), hindlimb unloading + LIPUS (HU+LIPUS) groups. The mice in the HU+LIPUS group received a 30 mW/cm2 LIPUS irradiation on gastrocnemius for 20 min/d. After 21 days, LIPUS significantly prevented the decrease in muscle mass and strength caused by tail suspension. The HU+LIPUS mice showed an enhanced desire to explore unfamiliar environments and their spatial learning and memory abilities, enabling them to quickly identify differences between different objects, as well as their social discrimination abilities. MSTN is a negative regulator of muscle growth and also plays a role in regulating cognition. LIPUS significantly inhibited MSTN expression in skeletal muscle and serum and its receptor ActRIIB expression in brain, upregulated AKT and BDNF expression in brain. Taken together, LIPUS may improve the cognitive dysfunction in hindlimb unloaded rats by inhibiting muscle atrophy through MSTN/AKT/BDNF pathway.
Collapse
Affiliation(s)
- Wanzhao Wang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Yi Zhong
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Yaling Zhou
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Yanan Yu
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Jiaxiang Li
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Sufang Kang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Zhanke Ma
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Xiushan Fan
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Lijun Sun
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| | - Liang Tang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, 710119, China
| |
Collapse
|
23
|
Pereira LF, Fontes-Pereira AJ, de Albuquerque Pereira WC. Influence of Low-Intensity Pulsed Ultrasound Parameters on the Bone Mineral Density in Rat Model: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1687-1698. [PMID: 37121881 DOI: 10.1016/j.ultrasmedbio.2023.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 02/23/2023] [Accepted: 03/03/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE Bone recovery typically depends on the age of organisms or the prevalence of metabolic disorders such as osteoporosis, which is a metabolic condition characterized by decreased bone strength and bone mineral density (BMD). Therefore, low-intensity pulsed ultrasound (LIPUS), a non-invasive method for osteogenic stimulation, presents promising results. However, heterogeneity in animal study designs is a typical characteristic. Hence, we conducted a systematic review to evaluate the effectiveness of LIPUS in the recovery of experimental bone defects using rat models. We examined the areal and volumetric BMD to identify LIPUS doses to be applied and evaluated the accuracy reported by previous studies. METHODS The Virtual Health Library regional portal, PubMed, Embase, EBSCOhost, Scopus and CAPES were reviewed for animal studies that compared fracture treatments based on LIPUS with sham or no treatments using rat models and reported BMD as an outcome. The tool provided by the Systematic Review Centre for Laboratory Animal Experimentation (SYRCLE) and the Collaborative Approach to Meta-Analysis and Review of Animal Data from Experimental Studies (CAMARADES) checklist were used to assess the bias and quality of such studies. RESULTS Of the six studies reviewed, the most frequently used LIPUS dose had an ultrasonic frequency of 1.0 MHz, repetition rate of 0.1 kHz and pulse duration of 2000 μs. An intensity (ISATA) of 30 mW/cm2 was the most preferred for bone recovery. However, the BMD could not solely irrefutably evaluate the effectiveness of LIPUS in bone recovery as the results were discordant with each other. The discrepancies in experimental methodologies, low-quality classifications and high risk of bias in the selected studies, however, did not validate the undertaking of a meta-analysis. CONCLUSION On the basis of the BMD results, no sufficient evidence was found to recommend the use of LIPUS for bone recovery in rat models. Thus, this systematic review indicates that the accuracy of such reports must be improved to improve their scientific quality to facilitate a transition of LIPUS applications from pre-clinical research to clinic use.
Collapse
Affiliation(s)
- Luiz Fernando Pereira
- Biomedical Engineering Program/COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
| | - Aldo José Fontes-Pereira
- Biomedical Engineering Program/COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; Centro Universitário Serra dos Órgãos-Unifeso, Teresópolis, Rio de Janeiro, Brazil
| | | |
Collapse
|
24
|
Kawano M, Wada K, Hemmi Y, Yokose S. Effect of Nd:YAG laser on bone formation in rat tibia defects: three-dimensional micro-computed tomography image analysis. Lasers Med Sci 2023; 38:158. [PMID: 37421518 DOI: 10.1007/s10103-023-03820-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 06/23/2023] [Indexed: 07/10/2023]
Abstract
Nd:YAG laser is in common clinical use for the treatment of tissue incision, transpiration, and haemostasis in soft tissues. However, few studies have reported the effects of low-level laser therapy (LLLT) from Nd:YAG laser on bone healing. The aim of this study was to perform three-dimensional (3D) morphological evaluation of the photobiomodulation of Nd:YAG laser in bone defects in rat tibiae using micro-computed tomography CT (micro-CT) imaging. A bone defect was created in each tibia of 30 rats. The right side was treated with LLLT from Nd:YAG laser (LT group) daily until sacrifice and the left tibiae served as controls (control group). All tibiae underwent micro-CT imaging at 7, 14, and 21 days after the operation. Three-dimensional image analysis of bone volume (BV) and bone surface area (BS) of new bone formation in the defects was performed and histologic analysis was conducted for all tibiae. Tibial BV and BS values were highest in both groups at 7 days after the operation and decreased at 14 days after operation. BV and BS values were both significantly higher in the LT group than in the control group at 7 and 14 days. There was no significant difference between the groups for either metric at 21 days. The present findings demonstrate that Nd:YAG laser simulates bone formation during the early healing period.
Collapse
Affiliation(s)
- Munemitsu Kawano
- Division of Endodontics and Operative Dentistry, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1 Keyakidai, Sakado, Saitama, 350-0283, Japan
| | - Kei Wada
- Division of Endodontics and Operative Dentistry, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1 Keyakidai, Sakado, Saitama, 350-0283, Japan.
| | - Yuichi Hemmi
- Division of Endodontics and Operative Dentistry, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1 Keyakidai, Sakado, Saitama, 350-0283, Japan
| | - Satoshi Yokose
- Division of Endodontics and Operative Dentistry, Department of Restorative and Biomaterials Sciences, Meikai University School of Dentistry, 1-1 Keyakidai, Sakado, Saitama, 350-0283, Japan
| |
Collapse
|
25
|
Li X, Li W, Sun L, Ren J, Xu Y, Zheng Y, Bai W. Efficacy of low-intensity pulsed ultrasound for the treatment of viral pneumonia: study protocol for a randomized controlled trial. Trials 2023; 24:389. [PMID: 37296443 DOI: 10.1186/s13063-023-07382-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 05/16/2023] [Indexed: 06/12/2023] Open
Abstract
BACKGROUND Viral pneumonia has always been a problem faced by clinicians because of its insidious onset, strong infectivity, and lack of effective drugs. Patients with advanced age or underlying diseases may experience more severe symptoms and are prone to severe ventilation dysfunction. Reducing pulmonary inflammation and improving clinical symptoms is the focus of current treatment. Low-intensity pulsed ultrasound (LIPUS) can mitigate inflammation and inhibit edema formation. We aimed to investigate the efficacy of therapeutic LIPUS in improving lung inflammation in hospitalized patients with viral pneumonia. METHODS Sixty eligible participants with clinically confirmed viral pneumonia will be assigned to either (1) intervention group (LIPUS stimulus), (2) control group (null stimulus), or (3) self-control group (LIPUS stimulated areas versus non-stimulated areas). The primary outcome will be the difference in the extent of absorption and dissipation of lung inflammation on computed tomography. Secondary outcomes include changes in lung inflammation on ultrasonography images, pulmonary function, blood gas analysis, fingertip arterial oxygen saturation, serum inflammatory factor levels, the sputum excretion volume, time to the disappearance of pulmonary rales, pneumonia status score, and course of pneumonia. Adverse events will be recorded. DISCUSSION This study is the first clinical study of the efficacy of therapeutic LIPUS in the treatment of viral pneumonia. Given that the current clinical recovery mainly depends on the body's self-limiting and conventional symptomatic treatment, LIPUS, as a new therapy method, might be a major advance in the treatment of viral pneumonia. TRIAL REGISTRATION ChiCTR2200059550 Chinese Clinical Trial Registry, May 3, 2022.
Collapse
Affiliation(s)
- Xiao Li
- Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Institute of Ultrasound in Medicine, Yishan Road 600, Shanghai, 200233, China
| | - Wen Li
- Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Institute of Ultrasound in Medicine, Yishan Road 600, Shanghai, 200233, China
| | - Lianjie Sun
- Department of Cardiovascular Surgery, The Affiliated Hospital of Qingdao University, Wutaishan Road 1677, Qingdao, 266555, China
| | - Junyi Ren
- Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Institute of Ultrasound in Medicine, Yishan Road 600, Shanghai, 200233, China
| | - Ying Xu
- Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Institute of Ultrasound in Medicine, Yishan Road 600, Shanghai, 200233, China
| | - Yuanyi Zheng
- Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Institute of Ultrasound in Medicine, Yishan Road 600, Shanghai, 200233, China.
| | - Wenkun Bai
- Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Institute of Ultrasound in Medicine, Yishan Road 600, Shanghai, 200233, China.
| |
Collapse
|
26
|
Támara-Patiño LM, Fontanilla-Duque GA, Sánchez-Cardozo OA, Ibañez-Pinilla M, Duran-Torres F, Rodríguez-Leguizamón G, Niño-Sandoval TC. A prospective non-fatal injuries assessment: A multivariate analysis in medical-legal examinations. J Forensic Leg Med 2023; 97:102543. [PMID: 37321156 DOI: 10.1016/j.jflm.2023.102543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 05/13/2023] [Accepted: 05/21/2023] [Indexed: 06/17/2023]
Abstract
OBJECTIVE To prospectively determine injury recovery time in the medical-legal examinations of non-fatal injuries and their associated factors, carried out by the National Institute of Legal Medicine and Forensic Sciences of Colombia to create a multivariate analysis. METHODS A prospective medical-legal assessment of non-fatal injuries was carried out on 281 individuals with complete follow-up, in which the observational unit of analysis was the most serious injury. Variables, such as sex, circumstances of the injury, the mechanism that caused the injury, medical certificate of incapacity to work, among others were related to the injury recovery time, measured in days. The Kruskal Wallis (K-W) ANOVA and a multivariate analysis using the ordinal regression model were applied. RESULTS In the multivariate analysis, the factors most associated with longer recovery time were the extent of joint damage (CR95%:1.47-5.94,p = 0.0001) and bone damage (CR95%:2.92-7.42,p < 0.001). In terms of circumstances of the injury, traffic accidents (CR95%:1.03-2.96,p < 0.001), medical-legal impairments (CR95%:0.34-2.19,p = 0.007), and complications of the primary injury (CR95%: 1.18-2.57,p < 0.001) had the greatest impact on recovery time. Others factors that significantly impacted injury recovery time are surgical treatments (IC95%: 0.33-3.26,p = 0.0164) and delayed treatment (CR95%:1.41-4.72,p < 0.001). A direct correlation (significant and moderately strong) was found between the recovery time of the injury and the days of incapacity for work (r = 0.802, p < 0.001). CONCLUSION This prospective analysis determined which variables were most strongly related to the medical-legal assessment of non-fatal injuries and the recovery time of said injuries. Further studies aimed at improving the strategies to help individuals complete the legal process are required.
Collapse
Affiliation(s)
- Liliana Marcela Támara-Patiño
- National Group of Clinical, Psychology and Forensic Psychiatry, National Institute of Legal Medicine and Forensic Sciences, Bogotá, Colombia.
| | | | - Oscar Armando Sánchez-Cardozo
- Bogotá Regional Office (DRB in Spanish), National Institute of Legal Medicine and Forensic Sciences, National University of Colombia, Bogotá, Colombia.
| | | | | | | | | |
Collapse
|
27
|
Liu Z, Li J, Bian Y, Zhang X, Cai X, Zheng Y. Low-intensity pulsed ultrasound reduces lymphedema by regulating macrophage polarization and enhancing microcirculation. Front Bioeng Biotechnol 2023; 11:1173169. [PMID: 37214283 PMCID: PMC10198614 DOI: 10.3389/fbioe.2023.1173169] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 04/25/2023] [Indexed: 05/24/2023] Open
Abstract
Background: Conventional therapies reduce lymphedema but do not cure it because they cannot modulate the pathophysiology of secondary lymphedema. Lymphedema is characterized by inflammation. We hypothesized that low-intensity pulsed ultrasound (LIPUS) treatment could reduce lymphedema by enhancing anti-inflammatory macrophage polarization and microcirculation. Methods: The rat tail secondary lymphedema model was established through the surgical ligation of lymphatic vessels. The rats were randomly divided into the normal, lymphedema, and LIPUS treatment groups. The LIPUS treatment (3 min daily) was applied 3 days after establishing the model. The total treatment period was 28 days. Swelling, fibro adipose deposition, and inflammation of the rat tail were evaluated by HE staining and Masson's staining. The photoacoustic imaging system and laser Doppler flowmetry were used to monitor microcirculation changes in rat tails after LIPUS treatment. The cell inflammation model was activated with lipopolysaccharides. Flow cytometry and fluorescence staining were used to observe the dynamic process of macrophage polarization. Results: After 28 days of treatment, compared with the lymphedema group, the tail circumference and subcutaneous tissue thickness of rats in the LIPUS group were decreased by 30%, the proportion of collagen fibers and the lymphatic vessel cross-sectional area was decreased, and tail blood flow was increased significantly. Cellular experiments revealed a decrease in CD86+ macrophages (M1) after LIPUS treatment. Conclusion: The transition of M1 macrophage and the promotion of microcirculation could be responsible for the beneficial effect of LIPUS on lymphedema.
Collapse
Affiliation(s)
- Zihao Liu
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University School of Medicine Affiliated Sixth People’s Hospital, Shanghai, China
| | - Jia Li
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University School of Medicine Affiliated Sixth People’s Hospital, Shanghai, China
| | - Yu Bian
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University School of Medicine Affiliated Sixth People’s Hospital, Shanghai, China
| | - Xiaojie Zhang
- Department of Neurology, Shanghai Jiao Tong University School of Medicine Affiliated Sixth People’s Hospital, Shanghai, China
| | - Xiaojun Cai
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University School of Medicine Affiliated Sixth People’s Hospital, Shanghai, China
| | - Yuanyi Zheng
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University School of Medicine Affiliated Sixth People’s Hospital, Shanghai, China
| |
Collapse
|
28
|
Aifantis ID, Ampadiotaki MM, Pallis D, Tsivelekas KK, Papadakis SA, Chronopoulos E. Biophysical Enhancement in Fracture Healing: A Review of the Literature. Cureus 2023; 15:e37704. [PMID: 37206524 PMCID: PMC10191239 DOI: 10.7759/cureus.37704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/17/2023] [Indexed: 05/21/2023] Open
Abstract
Bone healing constitutes a complex process involving cellular and pathophysiological mechanisms. Despite progress in osteosynthesis techniques, fracture union continues to be challenging. In some cases, it is not ultimately achieved or is delayed relative to the expected time resulting in economic and social outcomes for the patient and the health system. In addition to surgical treatment, biophysical methods have been developed to assist in fracture healing used in combination or individually. Biophysical stimulation is a non-invasive therapy used in orthopedic practice to increase and enhance tissue's reparative and anabolic activities. This study reviewed the existing literature, including electromagnetic fields, ultrasound, laser, extracorporeal shockwave therapy, and electrical stimulation, and revealed the efficacy of biophysical stimulation for bone healing. This study aims to define if these methods are helpful, especially in cases of non-union. Biophysical stimulation requires care and precision in use to ensure the success expected of it by physicians and patients.
Collapse
Affiliation(s)
| | | | - Dimitrios Pallis
- 2nd Orthopedic Department, KAT Attica General Hospital, Athens, GRC
| | | | | | | |
Collapse
|
29
|
Searle HKC, Lewis SR, Coyle C, Welch M, Griffin XL. Ultrasound and shockwave therapy for acute fractures in adults. Cochrane Database Syst Rev 2023; 3:CD008579. [PMID: 36866917 PMCID: PMC9983300 DOI: 10.1002/14651858.cd008579.pub4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
BACKGROUND The morbidity and socioeconomic costs of fractures are considerable. The length of time to healing is an important factor in determining a person's recovery after a fracture. Ultrasound may have a therapeutic role in reducing the time to union after fracture by stimulating osteoblasts and other bone-forming proteins. This is an update of a review previously published in February 2014. OBJECTIVES: To assess the effects of low-intensity ultrasound (LIPUS), high-intensity focused ultrasound (HIFUS) and extracorporeal shockwave therapies (ECSW) as part of the treatment of acute fractures in adults. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase (1980 to March 2022), Orthopaedic Proceedings, trial registers and reference lists of articles. SELECTION CRITERIA We included randomised controlled trials (RCTs) and quasi-RCTs including participants over 18 years of age with acute fractures (complete or stress fractures) treated with either LIPUS, HIFUS or ECSW versus a control or placebo-control. DATA COLLECTION AND ANALYSIS We used standard methodology expected by Cochrane. We collected data for the following critical outcomes: participant-reported quality of life, quantitative functional improvement, time to return to normal activities, time to fracture union, pain, delayed or non-union of fracture. We also collected data for treatment-related adverse events. We collected data in the short term (up to three months after surgery) and in the medium term (later than three months after surgery). MAIN RESULTS: We included 21 studies, involving 1543 fractures in 1517 participants; two studies were quasi-RCTs. Twenty studies tested LIPUS and one trial tested ECSW; no studies tested HIFUS. Four studies did not report any of the critical outcomes. All studies had unclear or high risk of bias in at least one domain. The certainty of the evidence was downgraded for imprecision, risk of bias and inconsistency. LIPUS versus control (20 studies, 1459 participants) We found very low-certainty evidence for the effect of LIPUS on Health-related quality of life (HRQoL) measured by SF-36 at up to one year after surgery for lower limb fractures (mean difference (MD) 0.06, 95% confidence interval (CI) -3.85 to 3.97, favours LIPUS; 3 studies, 393 participants). This result was compatible with a clinically important difference of 3 units with both LIPUS or control. There may be little to no difference in time to return to work after people had complete fractures of the upper or lower limbs (MD 1.96 days, 95% CI -2.13 to 6.04, favours control; 2 studies, 370 participants; low-certainty evidence). There is probably little or no difference in delayed union or non-union up to 12 months after surgery (RR 1.25, 95% CI 0.50 to 3.09, favours control; 7 studies, 746 participants; moderate-certainty evidence). Although data for delayed and non-union included both upper and lower limbs, we noted that there were no incidences of delayed or non-union in upper limb fractures. We did not pool data for time to fracture union (11 studies, 887 participants; very low-certainty evidence) because of substantial statistical heterogeneity which we could not explain. In upper limb fractures, MDs ranged from 0.32 to 40 fewer days to fracture union with LIPUS. In lower limb fractures, MDs ranged from 88 fewer days to 30 more days to fracture union. We also did not pool data for pain experienced at one month after surgery in people with upper limb fractures (2 studies, 148 participants; very low-certainty evidence) because of substantial unexplained statistical heterogeneity. Using a 10-point visual analogue scale, one study reported less pain with LIPUS (MD -1.7, 95% CI -3.03 to -0.37; 47 participants), and the effect was less precise in the other study (MD -0.4, 95% CI -0.61 to 0.53; 101 participants). We found little or no difference in skin irritation (a possible treatment-related adverse event) between groups but judged the certainty of the evidence from this small study to be very low (RR 0.94, 95% CI 0.06 to 14.65; 1 study, 101 participants). No studies reported data for functional recovery. Data for treatment adherence were inconsistently reported across studies, but was generally described to be good. Data for costs were reported for one study, with higher direct costs, as well as combined direct and indirect costs, for LIPUS use. ECSW versus control (1 study, 56 participants) We are uncertain whether ECSW reduces pain at 12 months after surgery in fractures of the lower limb (MD -0.62, 95% CI -0.97 to -0.27, favours ECSW); the difference between pain scores was unlikely to be clinically important, and the certainty of the evidence was very low. We are also uncertain of the effect of ECSW on delayed or non-union at 12 months because the certainty of this evidence is very low (RR 0.56, 95% CI 0.15 to 2.01; 1 study, 57 participants). There were no treatment-related adverse events. This study reported no data for HRQoL, functional recovery, time to return to normal activities, or time to fracture union. In addition, no data were available for adherence or cost. AUTHORS' CONCLUSIONS We were uncertain of the effectiveness of ultrasound and shock wave therapy for acute fractures in terms of patient-reported outcome measures (PROMS), for which few studies reported data. It is probable that LIPUS makes little or no difference to delayed union or non-union. Future trials should be double-blind, randomised, placebo-controlled trials recording validated PROMs and following up all trial participants. Whilst time to union is difficult to measure, the proportion of participants achieving clinical and radiographic union at each follow-up point should be ascertained, alongside adherence with the study protocol and cost of treatment in order to better inform clinical practice.
Collapse
Affiliation(s)
- Henry KC Searle
- Oxford University Clinical Academic Graduate School, University of Oxford, John Radcliffe Hospital, Oxford, UK
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Oxford, UK
- John Radcliffe Hospital, Oxford, UK
| | - Sharon R Lewis
- Blizard Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | | | - Matthew Welch
- Trauma & Orthopaedics, Great Western Hospitals NHS Foundation Trust, Swindon, UK
| | | |
Collapse
|
30
|
Low-intensity pulsed ultrasound partially reversed the deleterious effects of a severe spinal cord injury-induced bone loss and osteoporotic fracture healing in paraplegic rats. Spinal Cord 2023; 61:145-153. [PMID: 36266570 DOI: 10.1038/s41393-022-00863-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 10/03/2022] [Accepted: 10/06/2022] [Indexed: 11/08/2022]
Abstract
PURPOSE To evaluate the effects of low-intensity pulsed ultrasound (LIPUS) on the quality of femoral fracture callus formation in rats with severe osteoporosis secondary to spinal cord injury (SCI). METHODS Forty-five male rats were equally divided into three groups: the Sham group underwent sham surgery for SCI followed by surgery for femoral fracture on day ten post-spine surgery; the SCI group sustained a complete transection of the spinal cord and a femoral fracture ten days post-SCI; and the SCI group treated with ultrasound (SCI + US), which also sustained a femoral fracture on day ten post-SCI, concomitant with daily application of LIPUS at the fracture site. RESULTS At the non-fractured tibias, LIPUS counteracted the SCI-induced bone loss by normalizing the osteoblastic-related gene expression, decreasing resorptive area, increasing trabecular area, and decreasing RANK and RANK-L-positive areas, which resulted in higher cortical volume and stronger tibias. Likewise, LIPUS was effective at restoring bone fracture healing in SCI rats; by promoting endochondral ossification, increasing collagen deposition and OPG-positive-area, decreasing resorptive area, which led to higher density and improved microarchitecture, ultimately resulting in stronger fracture callus. CONCLUSION At the tibias, LIPUS counteracted the SCI-induced bone loss effects by simultaneously increasing bone formation and decreasing bone resorption. We also evidenced the osteogenic effects of LIPUS at partially restoring the endochondral ossification during callus formation, leading to a newly formed tissue with improved microarchitecture and mechanical integrity. Therefore, LIPUS may be an efficient and non-invasive approach to prevent bone loss and osteoporotic fracture in SCI individuals.
Collapse
|
31
|
Guevel B, Mathew ST, Coene RP, Maguire KJ, Williams KA, Micheli LJ, Milewski MD. Low-Intensity Pulsed Ultrasonography Plus Arthroscopic Drilling Does Not Improve Bone Healing More Than Arthroscopic Drilling Alone in Pediatric Patients With Stable Osteochondritis Dissecans of the Knee. Arthrosc Sports Med Rehabil 2023; 5:e225-e232. [PMID: 36866308 PMCID: PMC9971866 DOI: 10.1016/j.asmr.2022.11.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 11/09/2022] [Indexed: 01/12/2023] Open
Abstract
Purpose To determine whether adjuvant use of bone stimulation would improve the rate of healing in the operative management of stable osteochondritis dissecans (OCD) of the knee in pediatric patients. Methods This retrospective matched case-control study was performed at a single tertiary care pediatric hospital between January 2015 and September 2018. Patients who underwent antegrade drilling for stable femoral condyle OCD with greater than 2 years' follow-up were included. Preference was for all to receive postoperative bone stimulation; however, some were denied because of insurance coverage. This enabled us to create 2 matched groups of those who received postoperative bone stimulation and those who did not. Patients were matched on skeletal maturity, lesion location, sex, and age at surgery. The primary outcome measure was the rate of healing of the lesions determined by postoperative magnetic resonance imaging measurements at 3 months. Results Fifty-five patients were identified who met the inclusion and exclusion criteria. Twenty patients from the bone stimulator group (BSTIM) were matched to 20 patients from the no bone stimulator group (NBSTIM). Mean age for BSTIM at surgery was 13.2 years ± 2.0 (range, 10.9-16.7) and for NBSTIM at surgery 12.9 years ± 2.0 (range, 9.3-17.3). At 2 years, 36 patients (90%) in both groups went on to clinical healing without further interventions. In BSTIM, there was a mean decrease of 0.9 (±1.8) mm in lesion on coronal width and 12 patients (63%) had overall improved healing; in NBSTIM there was a mean decrease of 0.8 (±3.6) mm in coronal width and 14 patients (78%) had improved healing. No statistical differences in the rate of healing were found between the 2 groups (P = .706). Conclusion In antegrade drilling of stable knee OCD lesions in pediatric and adolescent patients, adjuvant bone stimulator use did not appear to improve radiographic or clinical healing. Level of evidence Level III, retrospective case-control study.
Collapse
Affiliation(s)
- Borna Guevel
- Boston Children's Hospital, Division of Sports Medicine, Department of Orthopaedic Surgery, Boston, Massachusetts, U.S.A
| | - Stephen T. Mathew
- Boston Children's Hospital, Division of Sports Medicine, Department of Orthopaedic Surgery, Boston, Massachusetts, U.S.A
| | - Ryan P. Coene
- Boston Children's Hospital, Division of Sports Medicine, Department of Orthopaedic Surgery, Boston, Massachusetts, U.S.A
| | | | - Kathryn A. Williams
- Boston Children’s Hospital, Biostatistics and Research Design Center, ICCTR Boston, Massachusetts, U.S.A
| | - Lyle J. Micheli
- Boston Children's Hospital, Division of Sports Medicine, Department of Orthopaedic Surgery, Boston, Massachusetts, U.S.A.,Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Matthew D. Milewski
- Boston Children's Hospital, Division of Sports Medicine, Department of Orthopaedic Surgery, Boston, Massachusetts, U.S.A.,Harvard Medical School, Boston, Massachusetts, U.S.A.,Address correspondence to Matthew Milewski, M.D., Boston Children's Hospital, Division of Sports Medicine, Department of Orthopaedic Surgery, 300 Longwood Avenue, Boston, MA 02115, U.S.A.
| |
Collapse
|
32
|
Bao SC, Li F, Xiao Y, Niu L, Zheng H. Peripheral focused ultrasound stimulation and its applications: From therapeutics to human-computer interaction. Front Neurosci 2023; 17:1115946. [PMID: 37123351 PMCID: PMC10140332 DOI: 10.3389/fnins.2023.1115946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Accepted: 03/24/2023] [Indexed: 05/02/2023] Open
Abstract
Peripheral focused ultrasound stimulation (pFUS) has gained increasing attention in the past few decades, because it can be delivered to peripheral nerves, neural endings, or sub-organs. With different stimulation parameters, ultrasound stimulation could induce different modulation effects. Depending on the transmission medium, pFUS can be classified as body-coupled US stimulation, commonly used for therapeutics or neuromodulation, or as an air-coupled contactless US haptic system, which provides sensory inputs and allows distinct human-computer interaction paradigms. Despite growing interest in pFUS, the underlying working mechanisms remain only partially understood, and many applications are still in their infancy. This review focused on existing applications, working mechanisms, the latest progress, and future directions of pFUS. In terms of therapeutics, large-sample randomized clinical trials in humans are needed to translate these state of art techniques into treatments for specific diseases. The airborne US for human-computer interaction is still in its preliminary stage, but further efforts in task-oriented US applications might provide a promising interaction tool soon.
Collapse
Affiliation(s)
- Shi-Chun Bao
- National Innovation Center for Advanced Medical Devices, Shenzhen, China
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Fei Li
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yang Xiao
- National Innovation Center for Advanced Medical Devices, Shenzhen, China
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Lili Niu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- *Correspondence: Hairong Zheng,
| |
Collapse
|
33
|
Muacevic A, Adler JR, Papadopoulos A. Low-Intensity Pulsed Ultrasound Treatment for Non-unions of Long Bone Fractures in a Scottish District General Hospital. Cureus 2023; 15:e34159. [PMID: 36843729 PMCID: PMC9949742 DOI: 10.7759/cureus.34159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/23/2023] [Indexed: 01/26/2023] Open
Abstract
OBJECTIVE Despite advances in treatment, the management of fracture non-union remains a challenging and complex problem in orthopaedics. Low-intensity pulsed ultrasound (LIPUS) treatment has been shown to be an effective, non-invasive, affordable treatment option. This treatment was evaluated in a Scottish district hospital over a nine-year period, which included the COVID-19 pandemic. MATERIALS AND METHODS This submission describes a case series at Dr Gray's Hospital in Scotland, 18 patients in whom fracture non-union was treated using LIPUS. RESULTS An overall healing rate of 94% was achieved. Exogen™ (Bioventus LLC, NC, USA) proved to be most successful in oligotrophic non-union. No observed patient demographic appeared predictive of outcome. LIPUS treatment failed in one case. No significant adverse effects of LIPUS were detected. CONCLUSION LIPUS represents a useful, cost-effective potential alternative to revision surgery. LIPUS may therefore be the preferred treatment when surgical intervention and face-to-face interactions are to be minimised, as during the COVID-19 pandemic.
Collapse
|
34
|
Phillips MR, Harrison A, Mehta S, Nolte PA, Bhandari M, Zura R. A scoping review of operative and non-invasive management in the treatment of non-unions. Injury 2022; 53:3872-3878. [PMID: 36424685 DOI: 10.1016/j.injury.2022.09.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 09/14/2022] [Accepted: 09/15/2022] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Non-union occurs when a fracture fails to adequately heal, and requires additional intervention to achieve union. The purpose of this scoping review is to provide a high-level overview of the existing non-union management literature. This review aims to highlight the current literature on non-union management, as well as identify key areas that require future research to provide a better understanding of potential non-union management strategies. METHODS This study utilized the scoping review framework from Arksey and O'Malley All relevant literature on non-union management was systematically searched for within the OVID Medline, OVID Embase, and Web of Science databases. As a scoping review, this study aimed to identify the high-level trends in non-union literature. This was assessed through a visual and numerical summary of the general themes in non-union literature, as well as the timeline in which these trends have occurred. RESULTS The literature search identified 8081 articles, of which 2210 articles were included. There is a large body of evidence for various surgical treatment options for non-union. The literature suggests healing rates between 80 and 100 percent for commonly utilized surgical procedures, such as plating with bone graft for long bones. Despite these beneficial healing rates, the requirement of a surgery creates a large socioeconomic burden. The possibility for bone growth stimulator (BGS) options to achieve non-union healing rates in a similar realm as surgical options suggests that the use of a BGS may be a beneficial option prior to surgical intervention, as this would potentially reduce the number of patients who would otherwise require surgery. CONCLUSION A large body of evidence exists on non-union management, which is largely comprised of case series and reports. The most commonly assessed non-unions include the tibia, wrist, and femur. Bone grafting, plating, and nailing are the most investigated treatment options. BGS are a non-operative treatment options for non-union that provide similar healing rates to surgical options in certain indications within initial observational data. BGS are a potential option for non-operative management of non-unions to reduce socioeconomic burdens of surgical intervention, with a need for further high-quality investigation in this therapeutic area.
Collapse
Affiliation(s)
- Mark R Phillips
- Department of Health Research Methods, Evidence, and Impact, McMaster University, Hamilton, Ontario, Canada.
| | - Andrew Harrison
- Bioventus International, Taurusavenue, Hoofddorp, the Netherlands
| | - Samir Mehta
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Peter A Nolte
- Department of Orthopaedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - Mohit Bhandari
- Department of Surgery, McMaster University, Hamilton, Ontario, Canada
| | - Robert Zura
- Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center, New Orleans, LA, USA
| |
Collapse
|
35
|
Muacevic A, Adler JR, Fadul A, Murphy CG. Low-Intensity Pulsed Ultrasound Therapy in Patients With Post-traumatic Delayed Union and Non-union. Cureus 2022; 14:e32267. [PMID: 36620791 PMCID: PMC9815886 DOI: 10.7759/cureus.32267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/06/2022] [Indexed: 12/12/2022] Open
Abstract
Background Fracture non-union can lead to significant patient morbidity with poor quality of life. Due to the cost, complexity, and potential risks of revision surgery, there has been an increased popularity in the use of low-intensity pulsed ultrasound therapy (LIPUS), which accelerates and promotes bone consolidation. There is an ongoing debate regarding the use and efficacy of LIPUS in delayed union and non-union. This study aims to assess the success rate of LIPUS therapy in patients treated for delayed and non-union fractures, explicitly focusing on the impact of patient co-morbidities and fracture characteristics. Method A retrospective observational study was performed of all consecutive patients who received LIPUS therapy in a single institution from January 2016 to September 2022. Of 127 identified patients, only 99 patients met our inclusion criteria. Data collection entailed reviewing the clinical notes to assess patients' sex, age, co-morbidities, initial treatment method, time to initiate LIPUS, whether a CT was performed to diagnose non-union, time to union and whether revision surgery was needed. Two independent senior orthopedic doctors reviewed the patients' radiographs, measured the interfragmentary bone gap of all fractures, and assessed whether the radiographic union was achieved. Results The mean age of the included patients was 52.5 (SD±16.9) years with a male-to-female ratio of 1:1.6. At initial presentation, 65 (out of 99) patients were treated surgically, whereas the rest were managed conservatively. 80.8% of patients developed atrophic non-union. All 99 included patients were fitted with LIPUS once delayed/ non-union was diagnosed; the average time to fitting was 5.1 (SD±3.9) months. Of these, 61.6% of patients were successfully treated with LIPUS with a clinical and radiological union at an average of 4.3 (SD±1.9) months. The rest of the patients needed further surgical intervention due to ongoing non-union. The interfragmentary bone gap was the only statistically significant factor influencing the success of LIPUS therapy (p=0.003). In contrast, no statistically significant association was identified between the outcome of LIPUS therapy and the patient's age, sex, diabetes, and smoking status. Conclusion This study demonstrated a 61.6% progression to union rate of patients treated with LIPUS therapy for delayed union and non-union. The interfragmentary bone gap was identified as the only statistically significant factor influencing the success of LIPUS therapy. In the current climate post-lockdown and with ongoing Covid 19 outbreaks impacting elective waiting lists negatively, there is increased value and demand for non-surgical treatment options. LIPUS therapy represents an important complementary non-surgical and low-risk treatment pathway for delayed union and non-union.
Collapse
|
36
|
The perceptions of clinicians using low-intensity pulsed ultrasound (LIPUS) for orthopaedic pathology: A national qualitative study. Injury 2022; 53:3214-3219. [PMID: 35803746 DOI: 10.1016/j.injury.2022.06.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 06/21/2022] [Accepted: 06/22/2022] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Low-intensity pulsed ultrasound (LIPUS) is a non-invasive treatment modality for delayed union or non-union of acute fractures. We aimed to assess the current use of LIPUS at a national level in the United Kingdom, why and how clinicians use it, what treatment protocols are followed, and what the current perceptions are on this technology. METHODOLOGY Using a detailed online survey compromised of 20 questions delivered to known LIPUS users, we were able to collect qualitative data on indication of use, type of machine used, personal views on the technology, frequency of usage, and treatment protocols. Each question was peer-reviewed to exclude bias. RESULTS A total of 70 respondents completed the survey. LIPUS was used by most clinicians for cases of non-union (N = 55, 78.5%) and delayed union (N = 51, 72.8%). The majority of respondents personally used a LIPUS device between 1 and 5 times in 12 months (N = 38, 54.3%). Most considered LIPUS a failure after three to six months of treatment without clinical improvement (N = 39, 55.7%). A total of 32 respondents (45.7%) mentioned the need for funding approval before accessing LIPUS technology. Poor revision surgery candidates (N = 48, 68.6%) and atrophic non-union (N = 46, 65.7%) were the most frequently cited reasons for using LIPUS technology as treatment. Most participants (N = 48, 68.6%) considered LIPUS to be cost-effective. Despite most clinicians being comfortable with the use of LIPUS, some respondents did not understand the basic science underpinning the technology nor could explain the need for LIPUS to patients comfortably. CONCLUSION LIPUS technology may have a significant role to play in the treatment of orthopaedic fracture related pathology. Regular users perceived the technology to be cost-effective and efficacious. Further research should standardize treatment protocols and aim to establish a national LIPUS registry.
Collapse
|
37
|
Liang C, Liu X, Yan Y, Sun R, Li J, Geng W. Effectiveness and Mechanisms of Low-Intensity Pulsed Ultrasound on Osseointegration of Dental Implants and Biological Functions of Bone Marrow Mesenchymal Stem Cells. Stem Cells Int 2022; 2022:7397335. [PMID: 36199628 PMCID: PMC9529500 DOI: 10.1155/2022/7397335] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 09/09/2022] [Indexed: 11/27/2022] Open
Abstract
Dental implant restoration is the preferred choice for patients with dentition defects or edentulous patients, and obtaining stable osseointegration is the determining factor for successful implant healing. The risk of implant failure during the healing stage is still an urgent problem in clinical practice due to differences in bone quality at different implant sites and the impact of some systemic diseases on bone tissue metabolism. Low-intensity pulsed ultrasound (LIPUS) is a noninvasive physical intervention method widely recognized in the treatment of bone fracture and joint damage repair. Moreover, many studies indicated that LIPUS could effectively promote the osseointegration of dental implants and improve the osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs). This review is aimed at investigating the research progress on the use of LIPUS in dental implant medicine from three aspects: (1) discuss the promoting effects of LIPUS on osseointegration and peri-implant bone regeneration, (2) summarize the effects and associated mechanisms of LIPUS on the biological functions of BMSCs, and (3) introduce the application and prospects of LIPUS in the clinical work of dental implantation. Although many challenges need to be overcome in the future, LIPUS is bound to be an efficient and convenient therapeutic method to improve the dental implantation success rate and expand clinical implant indications.
Collapse
Affiliation(s)
- Chao Liang
- Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing 100050, China
- Beijing Institute of Dental Research, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing 100050, China
| | - Xiu Liu
- Beijing Institute of Dental Research, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing 100050, China
| | - Yuwei Yan
- Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing 100050, China
| | - Rongxin Sun
- Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing 100050, China
| | - Jun Li
- Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing 100050, China
- Beijing Institute of Dental Research, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing 100050, China
| | - Wei Geng
- Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing 100050, China
| |
Collapse
|
38
|
Yang X, Li P, Lei J, Feng Y, Tang L, Guo J. Integrated Application of Low-Intensity Pulsed Ultrasound in Diagnosis and Treatment of Atrophied Skeletal Muscle Induced in Tail-Suspended Rats. Int J Mol Sci 2022; 23:10369. [PMID: 36142280 PMCID: PMC9498990 DOI: 10.3390/ijms231810369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2022] [Revised: 08/29/2022] [Accepted: 08/31/2022] [Indexed: 11/17/2022] Open
Abstract
Long-term exposure to microgravity leads to muscle atrophy, which is primarily characterized by a loss of muscle mass and strength and reduces one′s functional capability. A weightlessness-induced muscle atrophy model was established using the tail suspension test to evaluate the intervention or therapeutic effect of low-intensity pulsed ultrasound (LIPUS) on muscle atrophy. The rats were divided into five groups at random: the model group (B), the normal control group (NC), the sham-ultrasound control group (SUC), the LIPUS of 50 mW/cm2 radiation group (50 UR), and the LIPUS of 150 mW/cm2 radiation group (150 UR). Body weight, gastrocnemius weight, muscle force, and B-ultrasound images were used to evaluate muscle atrophy status. Results showed that the body weight, gastrocnemius weight, and image entropy of the tail suspension group were significantly lower than those of the control group (p < 0.01), confirming the presence of muscle atrophy. Although the results show that the muscle force and two weights of the rats stimulated by LIPUS are still much smaller than those of the NC group, they are significantly different from those of the pure tail suspension B group (p < 0.01). On day 14, the gastrocnemius forces of the rats exposed to 50 mW/cm2 and 150 mW/cm2 LIPUS were 150% and 165% of those in the B group. The gastrocnemius weights were both 135% of those in the B group. This suggests that ultrasound can, to a certain extent, prevent muscular atrophy.
Collapse
Affiliation(s)
- Xuebing Yang
- Shaanxi Key Laboratory of Ultrasonics, Shaanxi Normal University, Xi’an 710119, China
| | - Pan Li
- Shaanxi Key Laboratory of Ultrasonics, Shaanxi Normal University, Xi’an 710119, China
| | - Jiying Lei
- Shaanxi Key Laboratory of Ultrasonics, Shaanxi Normal University, Xi’an 710119, China
- Junior Middle Department, Shanxi Modern Bilingual School, Taiyuan 030031, China
| | - Yichen Feng
- Shaanxi Key Laboratory of Ultrasonics, Shaanxi Normal University, Xi’an 710119, China
| | - Liang Tang
- Institute of Sports Biology, Shaanxi Normal University, Xi’an 710119, China
| | - Jianzhong Guo
- Shaanxi Key Laboratory of Ultrasonics, Shaanxi Normal University, Xi’an 710119, China
| |
Collapse
|
39
|
Yao H, Zhang L, Yan S, He Y, Zhu H, Li Y, Wang D, Yang K. Low-intensity pulsed ultrasound/nanomechanical force generators enhance osteogenesis of BMSCs through microfilaments and TRPM7. J Nanobiotechnology 2022; 20:378. [PMID: 35964037 PMCID: PMC9375242 DOI: 10.1186/s12951-022-01587-3] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 08/03/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Low-intensity pulsed ultrasound (LIPUS) has been reported to accelerate fracture healing, but the mechanism is unclear and its efficacy needs to be further optimized. Ultrasound in combination with functionalized microbubbles has been shown to induce local shear forces and controllable mechanical stress in cells, amplifying the mechanical effects of LIPUS. Nanoscale lipid bubbles (nanobubbles) have high stability and good biosafety. However, the effect of LIPUS combined with functionalized nanobubbles on osteogenesis has rarely been studied. RESULTS In this study, we report cyclic arginine-glycine-aspartic acid-modified nanobubbles (cRGD-NBs), with a particle size of ~ 500 nm, able to actively target bone marrow mesenchymal stem cells (BMSCs) via integrin receptors. cRGD-NBs can act as nanomechanical force generators on the cell membrane, and further enhance the BMSCs osteogenesis and bone formation promoted by LIPUS. The polymerization of actin microfilaments and the mechanosensitive transient receptor potential melastatin 7 (TRPM7) ion channel play important roles in BMSCs osteogenesis promoted by LIPUS/cRGD-NBs. Moreover, the mutual regulation of TRPM7 and actin microfilaments promote the effect of LIPUS/cRGD-NBs. The extracellular Ca2 + influx, controlled partly by TRPM7, could participated in the effect of LIPUS/cRGD-NBs on BMSCs. CONCLUSIONS The nanomechanical force generators cRGD-NBs could promote osteogenesis of BMSCs and bone formation induced by LIPUS, through regulation TRPM7, actin cytoskeleton, and intracellular calcium oscillations. This study provides new directions for optimizing the efficacy of LIPUS for fracture healing, and a theoretical basis for the further application and development of LIPUS in clinical practice.
Collapse
Affiliation(s)
- Huan Yao
- Pediatric Research Institute, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing Engineering Research Center of Stem Cell Therapy, Chongqing, 400014, China.,Department of Ultrasound, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Liang Zhang
- Department of Ultrasound, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Shujin Yan
- Department of Ultrasound, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Yiman He
- Department of Ultrasound, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Hui Zhu
- Department of Ultrasound, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Yasha Li
- Pediatric Research Institute, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing Engineering Research Center of Stem Cell Therapy, Chongqing, 400014, China
| | - Dong Wang
- Department of Ultrasound, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Ke Yang
- Pediatric Research Institute, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing Engineering Research Center of Stem Cell Therapy, Chongqing, 400014, China.
| |
Collapse
|
40
|
Ganse B, Orth M, Roland M, Diebels S, Motzki P, Seelecke S, Kirsch SM, Welsch F, Andres A, Wickert K, Braun BJ, Pohlemann T. Concepts and clinical aspects of active implants for the treatment of bone fractures. Acta Biomater 2022; 146:1-9. [PMID: 35537678 DOI: 10.1016/j.actbio.2022.05.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 04/24/2022] [Accepted: 05/02/2022] [Indexed: 12/17/2022]
Abstract
Nonunion is a complication of long bone fractures that leads to disability, morbidity and high costs. Early detection is difficult and treatment through external stimulation and revision surgery is often a lengthy process. Therefore, alternative diagnostic and therapeutic options are currently being explored, including the use of external and internal sensors. Apart from monitoring fracture stiffness and displacement directly at the fracture site, it would be desirable if an implant could also vary its stiffness and apply an intervention to promote healing, if needed. This could be achieved either by a predetermined protocol, by remote control, or even by processing data and triggering the intervention itself (self-regulated 'intelligent' or 'smart' implant). So-called active or smart materials like shape memory alloys (SMA) have opened up opportunities to build active implants. For example, implants could stimulate fracture healing by active shortening and lengthening via SMA actuator wires; by emitting pulses, waves, or electromagnetic fields. However, it remains undefined which modes of application, forces, frequencies, force directions, time durations and periods, or other stimuli such implants should ideally deliver for the best result. The present paper reviews the literature on active implants and interventions for nonunion, discusses possible mechanisms of active implants and points out where further research and development are needed to build an active implant that applies the most ideal intervention. STATEMENT OF SIGNIFICANCE: Early detection of delays during fracture healing and timely intervention are difficult due to limitations of the current diagnostic strategies. New diagnostic options are under evaluation, including the use of external and internal sensors. In addition, it would be desirable if an implant could actively facilitate healing ('Intelligent' or 'smart' implant). Implants could stimulate fracture healing via active shortening and lengthening; by emitting pulses, waves, or electromagnetic fields. No such implants exist to date, but new composite materials and alloys have opened up opportunities to build such active implants, and several groups across the globe are currently working on their development. The present paper is the first review on this topic to date.
Collapse
|
41
|
Liu Z, Liu Q, Guo H, Liang J, Zhang Y. Overview of Physical and Pharmacological Therapy in Enhancing Bone Regeneration Formation During Distraction Osteogenesis. Front Cell Dev Biol 2022; 10:837430. [PMID: 35573673 PMCID: PMC9096102 DOI: 10.3389/fcell.2022.837430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 04/14/2022] [Indexed: 11/13/2022] Open
Abstract
Distraction osteogenesis (DO) is a kind of bone regeneration technology. The principle is to incise the cortical bone and apply continuous and stable distraction force to the fractured end of the cortical bone, thereby promoting the proliferation of osteoblastic cells in the tension microenvironment and stimulating new bone formation. However, the long consolidation course of DO presumably lead to several complications such as infection, fracture, scar formation, delayed union and malunion. Therefore, it is of clinical significance to reduce the long treatment duration. The current treatment strategy to promote osteogenesis in DO includes gene, growth factor, stem-cell, physical and pharmacological therapies. Among these methods, pharmacological and physical therapies are considered as safe, economical, convenience and effective. Recently, several physical and pharmacological therapies have been demonstrated with a decent ability to enhance bone regeneration during DO. In this review, we have comprehensively summarized the latest evidence for physical (Photonic, Waves, Gas, Mechanical, Electrical and Electromagnetic stimulation) and pharmacological (Bisphosphonates, Hormone, Metal compounds, Biologics, Chinese medicine, etc) therapies in DO. These evidences will bring novel and significant information for the bone healing during DO in the future.
Collapse
Affiliation(s)
- Ze Liu
- Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Qi Liu
- Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Hongbin Guo
- Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Jieyu Liang
- Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Yi Zhang
- Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
42
|
Chen Y, Zhou Y, Lin J, Zhang S. Challenges to Improve Bone Healing Under Diabetic Conditions. Front Endocrinol (Lausanne) 2022; 13:861878. [PMID: 35418946 PMCID: PMC8996179 DOI: 10.3389/fendo.2022.861878] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 03/02/2022] [Indexed: 12/17/2022] Open
Abstract
Diabetes mellitus (DM) can affect bone metabolism and the bone microenvironment, resulting in impaired bone healing. The mechanisms include oxidative stress, inflammation, the production of advanced glycation end products (AGEs), etc. Improving bone healing in diabetic patients has important clinical significance in promoting fracture healing and improving bone integration. In this paper, we reviewed the methods of improving bone healing under diabetic conditions, including drug therapy, biochemical cues, hyperbaric oxygen, ultrasound, laser and pulsed electromagnetic fields, although most studies are in preclinical stages. Meanwhile, we also pointed out some shortcomings and challenges, hoping to provide a potential therapeutic strategy for accelerating bone healing in patients with diabetes.
Collapse
Affiliation(s)
- Yiling Chen
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yue Zhou
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jie Lin
- Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, China
- *Correspondence: Jie Lin, ; Shiwen Zhang,
| | - Shiwen Zhang
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
- Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, China
- *Correspondence: Jie Lin, ; Shiwen Zhang,
| |
Collapse
|
43
|
Mancuso ME, Wilzman AR, Murdock KE, Troy KL. Effect of External Mechanical Stimuli on Human Bone: a narrative review. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2022; 4:012006. [PMID: 36310606 PMCID: PMC9616042 DOI: 10.1088/2516-1091/ac41bc] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Bone is a living composite material that has the capacity to adapt and respond to both internal and external stimuli. This capacity allows bone to adapt its structure to habitual loads and repair microdamage. Although human bone evolved to adapt to normal physiologic loading (for example from gravitational and muscle forces), these same biological pathways can potentially be activated through other types of external stimuli such as pulsed electromagnetic fields, mechanical vibration, and others. This review summarizes what is currently known about how human bone adapts to various types of external stimuli. We highlight how studies on sports-specific athletes and other exercise interventions have clarified the role of mechanical loading on bone structure. We also discuss clinical scenarios, such as spinal cord injury, where mechanical loading is drastically reduced, leading to rapid bone loss and permanent alterations to bone structure. Finally, we highlight areas of emerging research and unmet clinical need.
Collapse
|
44
|
Chen H, Zhu N, Osman M, Biskowitz R, Liu J, Khandare S, Butler P, Wong PK, Kothapalli SR. A transparent low intensity pulsed ultrasound (LIPUS) chip for high-throughput cell stimulation. LAB ON A CHIP 2021; 21:4734-4742. [PMID: 34739019 DOI: 10.1039/d1lc00667c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We report an on-chip platform for low-intensity pulsed ultrasound (LIPUS) stimulation of cells directly cultured on a biocompatible surface of a transparent ultrasound transducer (TUT) fabricated using lithium niobate. The high light transmittance (>80%) and compact size (3 mm × 3 mm × 2 mm) of TUTs allowed easy integration with powerful optical microscopy techniques with no additional acoustic coupling and risk for contamination. TUTs were excited with varying acoustic excitation parameters (voltage amplitude and duty cycle) and resulting live cell calcium signaling was simultaneously imaged using time-lapse confocal microscopy, while the temperature change was measured by a thermocouple. Quantitative single-cell fluorescence analysis revealed the dynamic calcium signaling responses and together with the temperature measurements elucidated the optimal stimulation parameters for non-thermal and thermal effects. The fluorescence change profile was distinct from the recorded temperature change (<1 degree Celsius) profile under LIPUS treatment conditions. Cell dead assay results confirmed cells remain viable after the LIPUS treatment. These results confirmed that the TUT platform enables controllable, safe, high-throughput, and uniform mechanical stimulation of all plated cells. The on-chip LIPUS stimulation using TUTs has the potential to attract several in vitro and in vivo biomedical applications such as controlling stem cell differentiation and proliferation, studying biomechanical properties of cancer cells, and gaining fundamental insights into mechanotransduction pathways when integrated with state-of-the-art high-speed and high-resolution microscopy techniques.
Collapse
Affiliation(s)
- Haoyang Chen
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
| | - Ninghao Zhu
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
| | - Mohamed Osman
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
| | - Ryan Biskowitz
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
| | - Jinyun Liu
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
| | - Shubham Khandare
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
| | - Peter Butler
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
| | - Pak Kin Wong
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
- Department of Mechanical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Sri-Rajasekhar Kothapalli
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
- Penn State Cancer Institute, The Pennsylvania State University, Hershey, PA 17033, USA
| |
Collapse
|