1
|
Biacchi M, Bhajun R, Saïd N, Beck A, François YN, Leize-Wagner E. Analysis of monoclonal antibody by a novel CE-UV/MALDI-MS interface. Electrophoresis 2014; 35:2986-95. [PMID: 25070377 DOI: 10.1002/elps.201400276] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Revised: 07/01/2014] [Accepted: 07/08/2014] [Indexed: 12/16/2022]
Abstract
mAbs are highly complex proteins that present a wide range of microheterogeneity that requires multiple analytical methods for full structure assessment and quality control. As a consequence, the characterization of mAbs on different levels is particularly product- and time-consuming. CE-MS couplings, especially to MALDI, appear really attractive methods for the characterization of biological samples. In this work, we report the last instrumental development and performance of the first totally automated off-line CE-UV/MALDI-MS/MS. This interface is based on the removal of the original UV cell of the CE apparatus, modification of the spotting device geometry, and creation of an integrated delivery matrix system. The performance of the method was evaluated with separation of five intact proteins and a tryptic digest mixture of nine proteins. Intact protein application shows the acquisition of electropherograms with high resolution and high repeatability. In the peptide mapping approach, a total number of 154 unique identified peptides were characterized using MS/MS spectra corresponding to average sequence coverage of 64.1%. Comparison with NanoLC/MALDI-MS/MS showed complementarity at the peptide level with an increase of 42% when using CE/MALDI-MS coupling. Finally, this work represents the first analysis of intact mAb charge variants by CZE using an MS detection. Moreover, using a peptide mapping approach CE-UV/MALDI-MS/MS fragmentation allowed 100% sequence coverage of the light chain and 92% of the heavy chain, and the separation of four major glycosylated peptides and their structural characterization.
Collapse
Affiliation(s)
- Michael Biacchi
- Laboratoire de Spectrométrie de Masse des Interactions et des Systèmes (LSMIS), CNRS-UMR 7140, Université de Strasbourg, Strasbourg, France
| | | | | | | | | | | |
Collapse
|
2
|
Park SG, Murray KK. Ambient laser ablation sampling for capillary electrophoresis mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:1673-1680. [PMID: 23821560 DOI: 10.1002/rcm.6618] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2013] [Revised: 05/06/2013] [Accepted: 05/06/2013] [Indexed: 06/02/2023]
Abstract
RATIONALE Ambient laser ablation with mass spectrometric detection is a powerful method for direct analysis of biological samples in their native environment. Capillary electrophoresis (CE) can separate complex mixtures of biological molecules prior to mass spectrometry (MS) analysis and an ambient sampling interface for CE/MS will allow the detection of minor components. METHODS An infrared (IR) laser ablated and transferred sample materials under ambient conditions for direct loading onto the CE separation column. Samples were deposited on a transparent target and ablated in transmission geometry using a pulsed mid-IR laser. The ablated materials were captured in the exposed sampling solvent and then loaded into a capillary by electrokinetic injection for separation and analysis by electrospray ionization (ESI)-MS. RESULTS The system was tested using mixtures of peptide and protein standards. It is estimated that tens of fmol of material was transferred from the ablation target for injection into the CE system and the theoretical plate number was between 1000 and 3000. CONCLUSIONS A novel interface for ambient sampling to CE/MS was developed. The interface is generally applicable and has potential utility for mass spectrometry imaging as well as the loading of microfluidic devices from untreated ambient samples.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA
| | | |
Collapse
|
3
|
Huang F, Murray KK. Finite element simulation of infrared laser ablation for mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2012; 26:2145-2150. [PMID: 22886810 DOI: 10.1002/rcm.6331] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
RATIONALE Laser ablation is widely used in conjunction with ambient ionization techniques, and a fundamental understanding of the mechanism of material removal is important to its optimal use in mass spectrometry. Finite element analysis simulates the laser material interaction on larger time and distance scales than atomistic approaches. Here, a two-dimensional finite element model was developed to simulate infrared laser irradiation of glycerol using a wavelength-tunable infrared (IR) laser. METHODS The laser fluence used for the simulations was varied from 1000 to 6000 J/m(2), the wavelength was varied from 2.7 to 3.7 µm, and both flat-top and Gaussian shape laser profiles were studied. RESULTS Phase explosion conditions were found for laser wavelengths near 3 µm (which corresponds to the OH stretch absorption of glycerol) and fluences above 2000 J/m(2). This suggests that laser ablation of glycerol is driven by phase explosion in the OH stretch region. The Gaussian profile generated regions of higher glycerol temperature, whereas the flat-top profile heated a larger volume of material above the phase explosion temperature. CONCLUSIONS These results suggest that the best performance for pulsed IR laser sample irradiation is in the wavelength range from 2.9 to 3.1 µm for materials with a strong OH stretch absorption.
Collapse
Affiliation(s)
- Fan Huang
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA
| | | |
Collapse
|
4
|
Zhu Z, Lu JJ, Liu S. Protein separation by capillary gel electrophoresis: a review. Anal Chim Acta 2012; 709:21-31. [PMID: 22122927 PMCID: PMC3227876 DOI: 10.1016/j.aca.2011.10.022] [Citation(s) in RCA: 132] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2011] [Revised: 10/02/2011] [Accepted: 10/07/2011] [Indexed: 12/13/2022]
Abstract
Capillary gel electrophoresis (CGE) has been used for protein separation for more than two decades. Due to the technology advancement, current CGE methods are becoming more and more robust and reliable for protein analysis, and some of the methods have been routinely used for the analysis of protein-based pharmaceuticals and quality controls. In light of this progress, we survey 147 papers related to CGE separations of proteins and present an overview of this technology. We first introduce briefly the early development of CGE. We then review the methodology, in which we specifically describe the matrices, coatings, and detection strategies used in CGE. CGE using microfabricated channels and incorporation of CGE with two-dimensional protein separations are also discussed in this section. We finally present a few representative applications of CGE for separating proteins in real-world samples.
Collapse
Affiliation(s)
- Zaifang Zhu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| | - Joann J. Lu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| | - Shaorong Liu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| |
Collapse
|
5
|
AL-Othman ZA, Ali I. NANO CAPILLARY ELECTROPHORESIS IN MICROCHIPS: A NEED OF THE PRESENT CENTURY. J LIQ CHROMATOGR R T 2011. [DOI: 10.1080/10826076.2011.566031] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Zeid A. AL-Othman
- a Department of Chemistry, College of Science , King Saud University , Riyadh, Kingdom of Saudi Arabia
| | - Imran Ali
- b Department of Chemistry , Jamia Millia Islamia, (Central University) , New Delhi, India
| |
Collapse
|
6
|
Park SG, Murray KK. Infrared laser ablation sample transfer for MALDI and electrospray. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2011; 22:1352-1362. [PMID: 21953189 DOI: 10.1007/s13361-011-0163-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2011] [Revised: 05/04/2011] [Accepted: 05/04/2011] [Indexed: 05/31/2023]
Abstract
We have used an infrared laser to ablate materials under ambient conditions that were captured in solvent droplets. The droplets were either deposited on a MALDI target for off-line analysis by MALDI time-of-flight mass spectrometry or flow-injected into a nanoelectrospray source of an ion trap mass spectrometer. An infrared optical parametric oscillator (OPO) laser system at 2.94 μm wavelength and approximately 1 mJ pulse energy was focused onto samples for ablation at atmospheric pressure. The ablated material was captured in a solvent droplet 1-2 mm in diameter that was suspended from a silica capillary a few millimeters above the sample target. Once the sample was transferred to the droplet by ablation, the droplet was deposited on a MALDI target. A saturated matrix solution was added to the deposited sample, or in some cases, the suspended capture droplet contained the matrix. Peptide and protein standards were used to assess the effects of the number of IR laser ablation shots, sample to droplet distance, capture droplet size, droplet solvent, and laser pulse energy. Droplet collected samples were also injected into a nanoelectrospray source of an ion trap mass spectrometer with a 500 nL injection loop. It is estimated that pmol quantities of material were transferred to the droplet with an efficiency of approximately 1%. The direct analysis of biological fluids for off-line MALDI and electrospray was demonstrated with blood, milk, and egg. The implications of this IR ablation sample transfer approach for ambient imaging are discussed.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA
| | | |
Collapse
|
7
|
Urban PL, Amantonico A, Zenobi R. Lab-on-a-plate: extending the functionality of MALDI-MS and LDI-MS targets. MASS SPECTROMETRY REVIEWS 2011; 30:435-478. [PMID: 21254192 DOI: 10.1002/mas.20288] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
We review the literature that describes how (matrix-assisted) laser desorption/ionization (MA)LDI target plates can be used not only as sample supports, but beyond that: as functional parts of analytical protocols that incorporate detection by MALDI-MS or matrix-free LDI-MS. Numerous steps of analytical procedures can be performed directly on the (MA)LDI target plates prior to the ionization of analytes in the ion source of a mass spectrometer. These include homogenization, preconcentration, amplification, purification, extraction, digestion, derivatization, synthesis, separation, detection with complementary techniques, data storage, or other steps. Therefore, we consider it helpful to define the "lab-on-a-plate" as a format for carrying out extensive sample treatment as well as bioassays directly on (MA)LDI target plates. This review introduces the lab-on-plate approach and illustrates it with the aid of relevant examples from the scientific and patent literature.
Collapse
Affiliation(s)
- Pawel L Urban
- Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093 Zurich, Switzerland
| | | | | |
Collapse
|
8
|
Lu JJ, Zhu Z, Wang W, Liu S. Coupling sodium dodecyl sulfate-capillary polyacrylamide gel electrophoresis with matrix-assisted laser desorption ionization time-of-flight mass spectrometry via a poly(tetrafluoroethylene) membrane. Anal Chem 2011; 83:1784-90. [PMID: 21309548 DOI: 10.1021/ac103148k] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis (PAGE) is a fundamental analytical technique for proteomic research, and SDS-capillary gel electrophoresis (CGE) is its miniaturized version. Compared to conventional slab-gel electrophoresis, SDS-CGE has many advantages such as increased separation efficiency, reduced separation time, and automated operation. SDS-CGE is not widely accepted in proteomic research primarily due to the difficulties in identifying the well-resolved proteins. MALDI-TOF-MS is an outstanding platform for protein identifications. Coupling the two would solve the problem but is extremely challenging because the MS detector has no access to the SDS-CGE-resolved proteins and the SDS interferes with MS detection. In this work we introduce an approach to address these issues. We discover that poly(tetrafluoroethylene) (PTFE) membranes are excellent materials for collecting SDS-CGE-separated proteins. We demonstrate that we can wash off the SDS bound to the collected proteins and identify these proteins on-membrane with MALDI-TOF-MS. We also show that we can immunoblot and Coomassie-stain the proteins collected on these membranes.
Collapse
Affiliation(s)
- Joann J Lu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | | | | | | |
Collapse
|
9
|
Kitagawa F, Otsuka K. Recent progress in microchip electrophoresis-mass spectrometry. J Pharm Biomed Anal 2010; 55:668-78. [PMID: 21130595 DOI: 10.1016/j.jpba.2010.11.013] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2010] [Revised: 11/10/2010] [Accepted: 11/10/2010] [Indexed: 01/30/2023]
Abstract
This review highlights the methodological and instrumental developments in microchip electrophoresis (MCE)-mass spectrometry (MS) from 1997. In MCE-MS, the development of ionization interface is one of the most important issues to realize highly sensitive detection and high separation efficiency. Among several interfaces, electrospray ionization (ESI) has been mainly employed to MCE-MS since a simple structure of the ESI interface is suitable for coupling with the microchips. Although the number of publications is still limited, laser desorption ionization (LDI) interface has also been developed for MCE-MS. The characteristics of the ESI and LDI interfaces applied to the electrophoresis microchips are presented in this review. The scope of applications in MCE-MS covers mainly biogenic compounds such as bioactive amines, peptides, tryptic digests and proteins. This review provides a comprehensive table listing the applications in MCE-MS.
Collapse
Affiliation(s)
- Fumihiko Kitagawa
- Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan.
| | | |
Collapse
|
10
|
Peš O, Preisler J. Off-line coupling of microcolumn separations to desorption mass spectrometry. J Chromatogr A 2010; 1217:3966-77. [DOI: 10.1016/j.chroma.2010.02.058] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2009] [Revised: 02/22/2010] [Accepted: 02/24/2010] [Indexed: 01/13/2023]
|
11
|
Microfluidic Device for Coupling Capillary Electrophoresis and Matrix-Assisted Laser Desorption Ionization-Mass Spectrometry. ACTA ACUST UNITED AC 2009. [DOI: 10.1016/j.jala.2009.02.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
We have designed and fabricated a polydimethylsiloxane (PDMS) microfluidic device for coupling capillary electrophoresis (CE) and matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS). The coupling is advantageous in biological research because CE has the power of separating analytes in a sample based on mobility difference and MALDI-MS provides accurate and sensitive mass analysis of the analytes. The goal is realized by fractionating the separated analytes inside the microfluidic device and pushing the analyte fractions into open reservoirs. Each analyte fraction is then mixed with a matrix solution and deposited on a MALDI target for MALDI-MS. Therefore, a two-step analysis of analytes in the form of CE-MALDI-MS is achieved by using the microfluidic device.
Collapse
|
12
|
Lee J, Soper SA, Murray KK. Microfluidics with MALDI analysis for proteomics--a review. Anal Chim Acta 2009; 649:180-90. [PMID: 19699392 DOI: 10.1016/j.aca.2009.07.037] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2009] [Revised: 07/13/2009] [Accepted: 07/15/2009] [Indexed: 01/01/2023]
Abstract
Various microfluidic devices have been developed for proteomic analyses and many of these have been designed specifically for mass spectrometry detection. In this review, we present an overview of chip fabrication, microfluidic components, and the interfacing of these devices to matrix-assisted laser desorption ionization (MALDI) mass spectrometry. These devices can be directly coupled to the mass spectrometer for on-line analysis in real-time, or samples can be analyzed on-chip or deposited onto targets for off-line readout. Several approaches for combining microfluidic devices with analytical functions such as sample cleanup, digestion, and separations with MALDI mass spectrometry are discussed.
Collapse
Affiliation(s)
- Jeonghoon Lee
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA
| | | | | |
Collapse
|
13
|
Lee J, Soper SA, Murray KK. Microfluidic chips for mass spectrometry-based proteomics. JOURNAL OF MASS SPECTROMETRY : JMS 2009; 44:579-93. [PMID: 19373851 DOI: 10.1002/jms.1585] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Microfluidic devices coupled to mass spectrometers have emerged as excellent tools for solving the complex analytical challenges associated with the field of proteomics. Current proteome identification procedures are accomplished through a series of steps that require many hours of labor-intensive work. Microfluidics can play an important role in proteomic sample preparation steps prior to mass spectral identification such as sample cleanup, digestion, and separations due to its ability to handle small sample quantities with the potential for high-throughput parallel analysis. To utilize microfluidic devices for proteomic analysis, an efficient interface between the microchip and the mass spectrometer is required. This tutorial provides an overview of the technologies and applications of microfluidic chips coupled to mass spectrometry for proteome analysis. Various approaches for combining microfluidic devices with electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) are summarized and applications of chip-based separations and digestion technologies to proteomic analysis are presented.
Collapse
Affiliation(s)
- Jeonghoon Lee
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, USA
| | | | | |
Collapse
|
14
|
Winkle RF, Nagy JM, Cass AEG, Sharma S. Towards microfluidic technology-based MALDI-MS platforms for drug discovery: a review. Expert Opin Drug Discov 2008; 3:1281-92. [DOI: 10.1517/17460441.3.11.1281] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
15
|
Peng Y, Pallandre A, Tran NT, Taverna M. Recent innovations in protein separation on microchips by electrophoretic methods. Electrophoresis 2008; 29:157-78. [DOI: 10.1002/elps.200700347] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
16
|
Rezenom YH, Dong J, Murray KK. Infrared laser-assisted desorption electrospray ionization mass spectrometry. Analyst 2007; 133:226-32. [PMID: 18227946 DOI: 10.1039/b715146b] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.
Collapse
Affiliation(s)
- Yohannes H Rezenom
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA
| | | | | |
Collapse
|
17
|
Jacksén J, Frisk T, Redeby T, Parmar V, van der Wijngaart W, Stemme G, Emmer A. Off-line integration of CE and MALDI-MS using a closed–open–closed microchannel system. Electrophoresis 2007; 28:2458-65. [PMID: 17577881 DOI: 10.1002/elps.200600735] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this work, a new technique for off-line hyphenation between CE and MALDI-MS is presented. Two closed fused-silica capillaries were connected via a silicon chip comprising an open microcanal. The EOF in the system was evaluated using mesityloxide or leucine-enkephalin as a sample and with a running buffer that rendered the analyte neutrally charged. Comparison was made between the EOF in a closed system (first capillary solely included in the electrical circuit) and in a closed-open system (first capillary and microcanal included in the electrical circuit). It was concluded that the experimental values of the EOF agreed with the theory. The influence of the capillary outer diameter on the peak dispersion was investigated using a closed-open-closed system (first capillary, microcanal and second capillary included in the electrical circuit). It was clearly seen that a capillary with 375 microm od induced considerably higher peak dispersion than a 150 microm od capillary, due to a larger liquid dead volume in the connection between the first capillary outlet and the microcanal. Mass spectrometric analysis has also been performed following CE separation runs in a closed-open-closed system with cytochrome c and lysozyme as model proteins. It was demonstrated that a signal distribution profile of the separated analytes could be recorded over a 30 mm long microcanal.
Collapse
Affiliation(s)
- Johan Jacksén
- Department of Chemistry, Division of Analytical Chemistry, School of Chemical Science and Engineering, Royal Institute of Technology, Stockholm, Sweden
| | | | | | | | | | | | | |
Collapse
|
18
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2007; 42:127-38. [PMID: 17199253 PMCID: PMC7166443 DOI: 10.1002/jms.1070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
In order to keep subscribers up‐to‐date with the latest developments in their field, John Wiley & Sons are providing a current awareness service in each issue of the journal. The bibliography contains newly published material in the field of mass spectrometry. Each bibliography is divided into 11 sections: 1 Books, Reviews & Symposia; 2 Instrumental Techniques & Methods; 3 Gas Phase Ion Chemistry; 4 Biology/Biochemistry: Amino Acids, Peptides & Proteins; Carbohydrates; Lipids; Nucleic Acids; 5 Pharmacology/Toxicology; 6 Natural Products; 7 Analysis of Organic Compounds; 8 Analysis of Inorganics/Organometallics; 9 Surface Analysis; 10 Environmental Analysis; 11 Elemental Analysis. Within each section, articles are listed in alphabetical order with respect to author (6 Weeks journals ‐ Search completed at 4th. Oct. 2006)
Collapse
|