1
|
Korpinen N. Differences in vertebral bone density between African apes. AMERICAN JOURNAL OF BIOLOGICAL ANTHROPOLOGY 2024:e24937. [PMID: 38644542 DOI: 10.1002/ajpa.24937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 03/08/2024] [Accepted: 04/02/2024] [Indexed: 04/23/2024]
Abstract
OBJECTIVES Low-energy vertebral fractures are a common health concern, especially in elderly people. Interestingly, African apes do not seem to experience as many vertebral fractures and the low-energy ones are even rarer. One potential explanation for this difference is the lower bone density in humans. Yet, only limited research has been done on the vertebral bone density of the great apes and these have mainly included only single vertebrae. Hence the study aim is to expand our understanding of the vertebral microstructure of African apes in multiple spinal segments. MATERIALS Bone density in the vertebral body of C7, T12, and L3 was measured from 32 Pan troglodytes and 26 Gorilla gorilla using peripheral quantitative computed tomography (pQCT). RESULTS There was a clear difference between the three individual vertebrae and consequently the spinal segments in terms of trabecular density and cortical density and thickness. The variation of these bone parameters between the vertebrae differed between the apes but was also different from those reported for humans. The chimpanzees were observed to have overall higher trabecular density, but gorillas had higher cortical density and thickness. Cortical thickness had a relatively strong association with the vertebral size. DISCUSSION Despite the similarity in locomotion and posture, the results show slight differences in the bone parameters and their variation between spinal segments in African apes. This variation also differs from humans and appears to indicate a complex influence of locomotion, posture, and body size on the different spinal segments.
Collapse
Affiliation(s)
- Niina Korpinen
- Department of Archaeology, Faculty of Humanities, University of Oulu, Oulu, Finland
| |
Collapse
|
2
|
Akçay B, Çolak TK, Apti A, Çolak İ. The Immediate Effect of Hanging Exercise and Muscle Cylinder Exercise on the Angle of Trunk Rotation in Adolescent Idiopathic Scoliosis. Healthcare (Basel) 2024; 12:305. [PMID: 38338189 PMCID: PMC10855408 DOI: 10.3390/healthcare12030305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 01/18/2024] [Accepted: 01/23/2024] [Indexed: 02/12/2024] Open
Abstract
(1) Background: Semi-hanging and muscle cylinder exercises have been defined as scoliosis-specific corrective exercises. The aim of this study was to evaluate the immediate effect of muscle cylinder and semi-hanging exercises on the angle of trunk rotation in patients with adolescent idiopathic scoliosis (AIS). (2) Methods: Twenty-seven patients with AIS with a mean age of 18.6 years were retrospectively analyzed. The angle of trunk rotation (ATR) values were measured before and after performing semi-hanging and standing muscle cylinder exercises. Both exercises were performed for three to five respiratory cycles. The semi-hanging exercise was performed first, followed by the muscle cylinder exercise, in this order, in all participants. For statistical analysis, the Wilcoxon signed-rank test was used to analyze ATR changes after the exercises, and the Kruskal-Wallis test was used to compare ATR changes according to the main curve location. (3) Results: The thoracic, thoracolumbar and lumbar maximum ATR values were significantly increased after the semi-hanging exercise (p < 0.001) and decreased after the muscle cylinder exercise (p < 0.001). The ATR change was greater in the lumbar region than in the thoracic and thoracolumbar regions. (4) Conclusion: The results of this study of a small group of patients emphasized that one of the scoliosis-specific corrective exercises, the standing muscle cylinder exercise, improved ATR, while the other, the semi-hanging exercise, worsened ATR in patients with AIS. It is recommended that each scoliosis-specific corrective exercise be evaluated and redesigned to maximize the three-dimensional corrective effect, considering the biomechanics of the spine and the pathomechanics of scoliosis.
Collapse
Affiliation(s)
- Burçin Akçay
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Bandırma Onyedi Eylül University, Balıkesir 10200, Turkey
| | - Tuğba Kuru Çolak
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Marmara University, Istanbul 34854, Turkey;
| | - Adnan Apti
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, İstanbul Kültür University, Istanbul 34191, Turkey;
| | - İlker Çolak
- VM Medical Park Maltepe, Istanbul 34846, Turkey;
| |
Collapse
|
3
|
Bernier E, Driscoll M. Numerical investigation of intra-abdominal pressure and spinal load-sharing upon the application of an abdominal belt. J Biomech 2023; 161:111863. [PMID: 37977959 DOI: 10.1016/j.jbiomech.2023.111863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 10/04/2023] [Accepted: 11/03/2023] [Indexed: 11/19/2023]
Abstract
Chronic low back pain patients may experience spinal instability. Abdominal belts (ABs) have been shown to improve spine stability, trunk stiffness, and resiliency to spinal perturbations. However, research on the contributing mechanisms is inconclusive. ABs may increase intra-abdominal pressure (IAP) and reduce paraspinal soft tissue contribution to spine stability without increasing spinal compressive loads. A finite element model (FEM) of the spine inclusive of the T1-S1 vertebrae, intervertebral discs (IVDs), ribcage, pelvis, soft tissues, and abdominal cavity, without active muscle forces was developed. An identical FEM with an AB was developed. Both FEMs underwent trunk flexion. Following validation, the models' intervertebral rotation (IVR), IAP, IVD pressure, and tensile stress in the multifidus (MF), erector spinae (ES), and thoracolumbar fascia (TLF) were compared. The inclusion of an AB resulted in a 3.8 kPa IAP increase, but a decreased average soft tissue tensile stress of 0.28 kPa. The TLF withstood the majority of tension being transferred across the paraspinal soft tissues (>70 %). The average IVR in the AB model decreased by 10 %, with the lumbar spine experiencing the largest reduction. The lumbar IVDs of the AB model likewise showed a 31 % reduction in average IVD pressure. Using an AB improved trunk bending stiffness, primarily in the lumbar spine. Wearing an AB had minimal effect on reducing tensile stress in theES. The skewed stress distribution towards the TLF suggests its large contribution to spine stability and the potential advantage in unloading the structure when wearing an AB, measured herein at8 %.
Collapse
Affiliation(s)
- Emeric Bernier
- Musculoskeletal Biomechanics Research Lab, Department of Mechanical Engineering, McGill University, 845 Sherbrooke St. W, Montréal, H3A 0G4, Québec, Canada; Orthopaedic Research Lab, Research Institute MUHC, Montreal General Hospital, McGill University, Montréal, H3G 1A4, Québec, Canada
| | - Mark Driscoll
- Musculoskeletal Biomechanics Research Lab, Department of Mechanical Engineering, McGill University, 845 Sherbrooke St. W, Montréal, H3A 0G4, Québec, Canada; Orthopaedic Research Lab, Research Institute MUHC, Montreal General Hospital, McGill University, Montréal, H3G 1A4, Québec, Canada.
| |
Collapse
|
4
|
Orbach MR, Mahoney J, Bucklen BS, Balasubramanian S. In vitro coupled motions of the whole human thoracic and lumbar spine with rib cage. JOR Spine 2023; 6:e1257. [PMID: 37780824 PMCID: PMC10540827 DOI: 10.1002/jsp2.1257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 04/07/2023] [Accepted: 04/13/2023] [Indexed: 10/03/2023] Open
Abstract
Study design In vitro biomechanical study investigating the coupled motions of the whole normative human thoracic spine (TS) and lumbar spine (LS) with rib cage. Objective To quantify the region-specific coupled motion patterns and magnitudes of the TS, thoracolumbar junction (TLJ), and LS simultaneously. Background Studying spinal coupled motions is important in understanding the development of complex spinal deformities and providing data for validating computational models. However, coupled motion patterns reported in vitro are controversial, and no quantitative data on region-specific coupled motions of the whole human TS and LS are available. Methods Pure, unconstrained bending moments of 8 Nm were applied to seven fresh-frozen human cadaveric TS and LS specimens (mean age: 70.3 ± 11.3 years) with rib cages to elicit flexion-extension (FE), lateral bending (LB), and axial rotation (AR). During each primary motion, region-specific rotational range of motion (ROM) data were captured. Results No statistically significant, consistent coupled motion patterns were observed during primary FE. During primary LB, there was significant (p < 0.05) ipsilateral AR in the TS and a general pattern of contralateral coupled AR in the TLJ and LS. There was also a tendency for the TS to extend and the LS to flex. During primary AR, significant coupled LB was ipsilateral in the TS and contralateral in both the TLJ and LS. Significant coupled flexion in the LS was also observed. Coupled LB and AR ROMs were not significantly different between the TS and LS or from one another. Conclusions The findings support evidence of consistent coupled motion patterns of the TS and LS during LB and AR. These novel data may serve as reference for computational model validations and future in vitro studies investigating spinal deformities and implants.
Collapse
Affiliation(s)
- Mattan R. Orbach
- School of Biomedical Engineering, Science and Health SystemsDrexel UniversityPhiladelphiaPennsylvaniaUSA
| | - Jonathan Mahoney
- Musculoskeletal Education and Research CenterA Division of Globus Medical, IncAudubonPennsylvaniaUSA
| | - Brandon S. Bucklen
- Musculoskeletal Education and Research CenterA Division of Globus Medical, IncAudubonPennsylvaniaUSA
| | - Sriram Balasubramanian
- School of Biomedical Engineering, Science and Health SystemsDrexel UniversityPhiladelphiaPennsylvaniaUSA
| |
Collapse
|
5
|
Liu W, Zang L, Kang N, Yang L, An L, Zhu W, Hai Y. Influence of configuration and anchor in ligamentous augmentation to prevent proximal junctional kyphosis: A finite element study. Front Bioeng Biotechnol 2022; 10:1014487. [DOI: 10.3389/fbioe.2022.1014487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 10/07/2022] [Indexed: 11/06/2022] Open
Abstract
Ligament augmentation has been applied during spinal surgery to prevent proximal junctional kyphosis (PJK), but the configuration and distal anchor strategies are diverse and inconsistent. The biomechanics of different ligament augmentation strategies are, therefore, unclear. We aimed to create a finite element model of the spine for segments T6–S1. Model Intact was the native form, and Model IF was instrumented with a pedicle screw from segments T10 to S1. The remaining models were based on Model IF, with ligament augmentation configurations as common (CM), chained (CH), common and chained (CHM); and distal anchors to the spinous process (SP), crosslink (CL), and pedicle screw (PS), creating SP-CH, PS-CHM, PS-CH, PS-CM, CL-CHM, CL-CH, and CL-CM models. The range of motion (ROM) and maximum stress on the intervertebral disc (IVD), PS, and interspinous and supraspinous ligaments (ISL/SSL) was measured. In the PS-CH model, the ROM for segments T9–T10 was 73% (of Model Intact). In the CL-CHM, CL-CH, CL-CM, PS-CM, and PS-CHM models, the ROM was 8%, 17%, 7%, 13%, and 30%, respectively. The PS-CH method had the highest maximum stress on IVD and ISL/SSL, at 80% and 72%, respectively. The crosslink was more preferable as the distal anchor. In the uppermost instrumented vertebrae (UIV) + 1/UIV segment, the CM was the most effective configuration. The PS-CH model had the highest flexion load on the UIV + 1/UIV segment and the CL-CM model provided the greatest reduction. The CL-CM model should be verified in a clinical trial. The influence of configuration and anchor in ligament augmentation is important for the choice of surgical strategy and improvement of technique.
Collapse
|
6
|
Liebsch C, Wilke HJ. How Does the Rib Cage Affect the Biomechanical Properties of the Thoracic Spine? A Systematic Literature Review. Front Bioeng Biotechnol 2022; 10:904539. [PMID: 35782518 PMCID: PMC9240654 DOI: 10.3389/fbioe.2022.904539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 05/06/2022] [Indexed: 11/29/2022] Open
Abstract
The vast majority of previous experimental studies on the thoracic spine were performed without the entire rib cage, while significant contributive aspects regarding stability and motion behavior were shown in several other studies. The aim of this literature review was to pool and increase evidence on the effect of the rib cage on human thoracic spinal biomechanical characteristics by collating and interrelating previous experimental findings in order to support interpretations of in vitro and in silico studies disregarding the rib cage to create comparability and reproducibility for all studies including the rib cage and provide combined comparative data for future biomechanical studies on the thoracic spine. After a systematic literature search corresponding to PRISMA guidelines, eleven studies were included and quantitatively evaluated in this review. The combined data exhibited that the rib cage increases the thoracic spinal stability in all motion planes, primarily in axial rotation and predominantly in the upper thorax half, reducing thoracic spinal range of motion, neutral zone, and intradiscal pressure, while increasing thoracic spinal neutral and elastic zone stiffness, compression resistance, and, in a neutral position, the intradiscal pressure. In particular, the costosternal connection was found to be the primary stabilizer and an essential determinant for the kinematics of the overall thoracic spine, while the costotransverse and costovertebral joints predominantly reinforce the stability of the single thoracic spinal segments but do not alter thoracic spinal kinematics. Neutral zone and neutral zone stiffness were more affected by rib cage removal than the range of motion and elastic zone stiffness, thus also representing the essential parameters for destabilization of the thoracic spine. As a result, the rib cage and thoracic spine form a biomechanical entity that should not be separated. Therefore, usage of entire human non-degenerated thoracic spine and rib cage specimens together with pure moment application and sagittal curvature determination is recommended for future in vitro testing in order to ensure comparability, reproducibility, and quasi-physiological validity.
Collapse
|
7
|
Influence of Rib Cage on Static Characteristics of Scoliotic Spine. Appl Bionics Biomech 2020; 2020:8858686. [PMID: 33133237 PMCID: PMC7591979 DOI: 10.1155/2020/8858686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Revised: 09/11/2020] [Accepted: 09/19/2020] [Indexed: 11/17/2022] Open
Abstract
Background Scoliosis is a three-dimensional (3D) deformity of the spine, which affects the patient's appearance and may lead to abnormal heart and lung function. The rib cage is a structure composed of ribs, sternum, and costal cartilage, which plays a vital role in stabilising the thoracolumbar spine. This study investigates the influence of the rib cage on the static characteristics of the scoliotic spine. Methods Two types of 3D finite element (FE) models with or without rib cage (from T1 to S) were established and analysed based on computed tomography (CT) images, to determine the effects of the rib cage on the static characteristics of the scoliotic spine. The FE software, ABAQUS, was used to analyse the static behaviours of scoliotic spine models under a range of loading conditions, including left side bending, right side bending, front tilt, rear supine, and vertical compression. The changes in the von Mises stress (VMS) within the intervertebral discs of spine models with or without rib cage were studied and compared. Results After including the rib cage, the maximum VMS at the stress concentrations of the normal and scoliotic spine effectively reduced. The VMS in normal intervertebral discs was gentler than that of scoliotic ones. However, the scoliotic spine was more likely to produce large stress concentration in the intervertebral discs of scoliotic segments. Conclusions Under the common postures, intervertebral discs of scoliotic segments are more susceptible to generate stress concentrations compared with the normal spine. The rib cage could effectively keep the intervertebral discs of scoliotic segments from further injuries. These results are of great significance for the prevention and treatment of the scoliotic spine.
Collapse
|
8
|
The influence of the rib cage on the static and dynamic stability responses of the scoliotic spine. Sci Rep 2020; 10:16916. [PMID: 33037307 PMCID: PMC7547652 DOI: 10.1038/s41598-020-73881-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 09/21/2020] [Indexed: 12/15/2022] Open
Abstract
The thoracic cage plays an important role in maintaining the stability of the thoracolumbar spine. In this study, the influence of a rib cage on static and dynamic responses in normal and scoliotic spines was investigated. Four spinal finite element (FE) models (T1-S), representing a normal spine with rib cage (N1), normal spine without rib cage (N2), a scoliotic spine with rib cage (S1) and a scoliotic spine without rib cage (S2), were established based on computed tomography (CT) images, and static, modal, and steady-state analyses were conducted. In S2, the Von Mises stress (VMS) was clearly decreased compared to S1 for four bending loadings. N2 and N1 showed a similar VMS to each other, and there was a significant increase in axial compression in N2 and S2 compared to N1 and S1, respectively. The U magnitude values of N2 and S2 were higher than in N1 and S1 for five loadings, respectively. The resonant frequencies of N2 and S2 were lower than those in N1 and S1, respectively. In steady-state analysis, maximum amplitudes of vibration for N2 and S2 were significantly larger than N1 and S1, respectively. This study has revealed that the rib cage improves spinal stability in vibrating environments and contributes to stability in scoliotic spines under static and dynamic loadings.
Collapse
|
9
|
Wilke HJ, Herkommer A, Werner K, Liebsch C. In vitro Analysis of the Intradiscal Pressure of the Thoracic Spine. Front Bioeng Biotechnol 2020; 8:614. [PMID: 32626699 PMCID: PMC7311578 DOI: 10.3389/fbioe.2020.00614] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Accepted: 05/20/2020] [Indexed: 11/13/2022] Open
Abstract
The hydrostatic pressure of the nucleus pulposus represents an important parameter in the characterization of spinal biomechanics, affecting the segmental stability as well as the stress distribution across the anulus fibrosus and the endplates. For the development of experimental setups and the validation of numerical models of the spine, intradiscal pressure (IDP) values under defined boundary conditions are therefore essential. Due to the lack of data regarding the thoracic spine, the purpose of this in vitro study was to quantify the IDP of human thoracic spinal motion segments under pure moment loading. Thirty fresh-frozen functional spinal units from 19 donors, aged between 43 and 75 years, including all segmental levels from T1-T2 to T11-T12, were loaded up to 7.5 Nm in flexion/extension, lateral bending, and axial rotation. During loading, the IDP was measured using a flexible sensor tube, which was inserted into the nucleus pulposus under x-ray control. Pressure values were evaluated from third full loading cycles at 0.0, 2.5, 5.0, and 7.5 Nm in each motion direction. Highest IDP increase was found in flexion, being significantly (p < 0.05) increased compared to extension IDP. Median pressure values were lowest in lateral bending while exhibiting a large variation range. Flexion IDP was significantly increased in the upper compared to the mid- and lower thoracic spine, whereas extension IDP was significantly higher in the lower compared to the upper thoracic spine, both showing significant (p < 0.01) linear correlation with the segmental level at 7.5 Nm (flexion: r = -0.629, extension: r = 0.500). No significant effects of sex or age were detected, however trends toward higher IDP in specimens from female donors and decreasing IDP with increasing age, potentially caused by fibrotic degenerative changes in the nucleus pulposus tissue. Sagittal and transversal cuttings after testing revealed possible relationships between nucleus pulposus quality and pressure moment characteristics, overall leading to low or negative intrinsic IDP and non-linear pressure-moment behavior in case of fibrotic tissue alterations. In conclusion, this study provides insights into thoracic spinal IDP and offers a large dataset for the validation of numerical models of the thoracic spine.
Collapse
Affiliation(s)
- Hans-Joachim Wilke
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University, Ulm, Germany
| | - Andrea Herkommer
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University, Ulm, Germany
| | - Karin Werner
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University, Ulm, Germany
| | - Christian Liebsch
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University, Ulm, Germany
| |
Collapse
|
10
|
Liebsch C, Wilke HJ. Rib Presence, Anterior Rib Cage Integrity, and Segmental Length Affect the Stability of the Human Thoracic Spine: An in vitro Study. Front Bioeng Biotechnol 2020; 8:46. [PMID: 32117927 PMCID: PMC7018667 DOI: 10.3389/fbioe.2020.00046] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 01/21/2020] [Indexed: 11/13/2022] Open
Abstract
The effects of segmental length as well as anterior rib cage and costovertebral joint integrity on thoracic spinal stability have not been extensively investigated, but are essential for the calibration and validation of numerical models of the thoracic spine and rib cage. The aim of the study was to quantify these effects by in vitro experiments. Eight human thoracic spine specimens (C7-L1) including the rib cage were loaded with pure moments of 5 Nm in flexion/extension, lateral bending, and axial rotation while tracking the motions of all functional spinal units. Specimens were tested stepwise in four different conditions: (1) In the intact condition, (2) after cutting all anterior rib-to-rib connections, (3) after partitioning the polysegmental specimens into monosegmental specimens, and (4) after removing the ribs in the monosegmental condition. Significant increases of the range of motion (p < 0.05) were especially found at the segmental levels of the upper half of the thoracic spine in all motion planes and for all resection steps, particularly in axial rotation, while the stabilizing effects of the structures decreased in inferior direction. Partitioning of polysegmental specimens into monosegmental specimens primarily affected the stability in lateral bending, while the effects of resection were generally lowest in flexion/extension. Presence of the ribs, anterior rib cage integrity, and segmental length all affect the thoracic spinal stability and have therefore to be considered in the calibration process of numerical models of the thoracic spine and rib cage.
Collapse
Affiliation(s)
- Christian Liebsch
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University, Ulm, Germany
| | - Hans-Joachim Wilke
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University, Ulm, Germany
| |
Collapse
|
11
|
Murphy J, McLoughlin E, Davies A, James S, Botchu R. Is T9-11 the true thoracolumbar transition zone? J Clin Orthop Trauma 2020; 11:891-895. [PMID: 32904168 PMCID: PMC7452342 DOI: 10.1016/j.jcot.2019.10.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 08/26/2019] [Accepted: 10/07/2019] [Indexed: 10/25/2022] Open
Abstract
OBJECTIVE Degenerative thoracic stenosis has been shown to most frequently involve the lower thoracic segments (T9-T12) where there is greater mobility and vulnerability due to flexion, extension and rotation of the spine. The thoracolumbar junction is considered anatomically to be T12-L1; the anatomical transition between the relatively immobile thoracic spine and relatively mobile lumbar spine. From anecdotal experience at our institution, we hypothesise that the true thoracolumbar junction is higher, at T10-11; the point of transition from floating to false ribs resulting in increased mobility at T10-11. METHODS AND MATERIALS A retrospective review was performed of MRI lumbar and whole spine performed on patients aged 10-40 years in our institution over a 5-year period. Patients with previous surgery, chronic spinal disorders and congenital abnormalities were excluded from the study. Intervertebral discs from T8-9 to L1-2 were assessed for evidence of degeneration using the Pfirrmann grading system. Data obtained from a study using computer-based models to assess mean resultant loads in flexion, sitting and standing from T8-9 to L1-2 on patients aged 18-35 years was also analysed. The mean load gradients between two consecutive discs from T8 to L2 were analysed. Statistical analysis was performed with SPSS (p < 0.05 was considered statistically significant). RESULTS Three-hundred and twenty-two MRI studies were reviewed. Mean Pfirrmann grade was highest at T8-9 and T9-10 (1.35 ± 0.99 and 1.32 ± 0.93 respectively).Pfirrmann grade differed significantly at each level (χ2 = 45.137 p = 0.001). Difference in mean load gradient from T9 to T11 was significantly higher than mean load gradient across T11 to L1 in both sitting and standing (0.095 ± 0.062 vs 0.050 ± 0.044 kN; p = 0.007, and 0.101 ± 0.061 kN vs 0.040 ± 0.054 kN; p = 0.007). CONCLUSION The changes in segmental loads and more severe disc degeneration at T9-11 compared to T11-L1 support our hypothesis that the true thoracolumbar transition is higher than expected, at T10-11; where the rib cage transitions from floating to false ribs.
Collapse
Affiliation(s)
| | | | | | | | - R. Botchu
- Corresponding author. Department of Musculoskeletal Radiology, The Royal Orthopedic Hospital, Bristol Road South, Northfield, Birmingham, UK.
| |
Collapse
|
12
|
Zhang C, Mannen EM, Sis HL, Cadel ES, Wong BM, Wang W, Cheng B, Friis EA, Anderson DE. Moment-rotation behavior of intervertebral joints in flexion-extension, lateral bending, and axial rotation at all levels of the human spine: A structured review and meta-regression analysis. J Biomech 2019; 100:109579. [PMID: 31911050 DOI: 10.1016/j.jbiomech.2019.109579] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 12/06/2019] [Accepted: 12/11/2019] [Indexed: 10/25/2022]
Abstract
Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response across all levels of the spine is lacking. This review aims to characterize moment-rotation response in a consistent manner for all levels of the human spine. A literature search was conducted in PubMed for moment versus rotation data from mechanical testing of intact human cadaveric intervertebral joint specimens in flexion-extension, lateral bending, and axial rotation. A total of 45 studies were included, providing data from testing of an estimated 1,648 intervertebral joints from 518 human cadavers. We used mixed-effects regression analysis to create 75 regression models of moment-rotation response (25 intervertebral joints × 3 directions). We found that a cubic polynomial model provides a good representation of the moment-rotation behavior of most intervertebral joints, and that compressive loading increases rotational stiffness throughout the spine in all directions. The results allow for the direct evaluation of intervertebral ranges of motion across the whole of the spine for given loading conditions. The random-effects outcomes, representing standard deviations of the model coefficients across the dataset, can aid understanding of normal variations in moment-rotation responses. Overall these results fill a large gap, providing the first realistic and comprehensive representations of moment-rotation behavior at all levels of the spine, with broad implications for surgical planning, medical device design, computational modeling, and understanding of spine biomechanics.
Collapse
Affiliation(s)
- Chaofei Zhang
- Beth Israel Deaconess Medical Center, Boston, MA, USA; Tsinghua University, Beijing, China
| | - Erin M Mannen
- University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | | | | | | | | | - Bo Cheng
- Tsinghua University, Beijing, China
| | | | - Dennis E Anderson
- Beth Israel Deaconess Medical Center, Boston, MA, USA; Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
13
|
Rahm MD, Brooks DM, Harris JA, Hart RA, Hughes JL, Ferrick BJ, Bucklen BS. Stabilizing effect of the rib cage on adjacent segment motion following thoracolumbar posterior fixation of the human thoracic cadaveric spine: A biomechanical study. Clin Biomech (Bristol, Avon) 2019; 70:217-222. [PMID: 31669919 DOI: 10.1016/j.clinbiomech.2019.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2019] [Revised: 09/19/2019] [Accepted: 10/05/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Although the rib cage provides substantial stability to the thoracic spine, few biomechanical studies have incorporated it into their testing model, and no studies have determined the influence of the rib cage on adjacent segment motion of long fusion constructs. The present biomechanical study aimed to determine the mechanical contribution of the intact rib cage during the testing of instrumented specimens. METHODS A cyclic loading (CL) protocol with instrumentation (T4-L2 pedicle screw-rod fixation) was conducted on five thoracic spines (C7-L2) with intact rib cages. Range of motion (±5 Nm pure moment) in flexion-extension, lateral bending, and axial rotation was captured for intact ribs, partial ribs, and no ribs conditions. Comparisons at the supra-adjacent (T2-T3), adjacent (T3-T4), first instrumented (T4-T5), and second instrumented (T5-T6) levels were made between conditions (P ≤ 0.05). FINDINGS A trend of increased motion at the adjacent level was seen for partial ribs and no ribs in all 3 bending modes. This trend was also observed at the supra-adjacent level for both conditions. No significant changes in motion compared to the intact ribs condition were seen at the first and second instrumented levels (P > 0.05). INTERPRETATION The segment adjacent to long fusion constructs, which may appear more grossly unstable when tested in the disarticulated spine, is reinforced by the rib cage. In order to avoid overestimating adjacent level motion, when testing the effectiveness of surgical techniques of the thoracic spine, inclusion of the rib cage may be warranted to better reflect clinical circumstances.
Collapse
Affiliation(s)
- Mark D Rahm
- Department of Orthopaedic Surgery, Baylor Scott and White Health/Texas A&M University College of Medicine, 2401 S 31(st) Street, Temple, Texas, 76508, USA.
| | - Daina M Brooks
- Musculoskeletal Education and Research Center, Globus Medical, Inc., 2560 General Armistead Avenue, Audubon, PA 19403, USA.
| | - Jonathan A Harris
- Musculoskeletal Education and Research Center, Globus Medical, Inc., 2560 General Armistead Avenue, Audubon, PA 19403, USA.
| | - Robert A Hart
- Department of Orthopaedic Surgery, Swedish Neuroscience Institute, 601 Broadway, Seattle, WA 98122, USA.
| | - Jessica L Hughes
- Department of Orthopaedic Surgery, Baylor Scott and White Health/Texas A&M University College of Medicine, 2401 S 31(st) Street, Temple, Texas, 76508, USA.
| | - Bryan J Ferrick
- Drexel University School of Biomedical Engineering, Science and Health Systems, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Brandon S Bucklen
- Musculoskeletal Education and Research Center, Globus Medical, Inc., 2560 General Armistead Avenue, Audubon, PA 19403, USA.
| |
Collapse
|
14
|
Meng Z, Wang C, Guo X, Chen W, Ding W. Analysis of the disc pressure of the upper thoracic spine using pressure-sensitive film: an experimental study in porcine model-implications for scoliosis progression. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:1069-1079. [PMID: 31617153 DOI: 10.1007/s13246-019-00804-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 09/30/2019] [Indexed: 11/28/2022]
Abstract
There has been few studies focusing on the disc pressure of the upper thoracic spine and it still lacks the quantitative pressure measurement of each spinal disc segment. The aim of this study was to study the pressure changes of intervertebral disc in porcine upper thoracic spine using pressure-sensitive film. Twelve porcine thoracic motion segments were harvested and successively loaded with vertical loads of 100 N, 150 N, and 200 N during 5° of anterior flexion, 5° of posterior extension and 5° of lateral bending. The resulting pressure values were measured. During anterior flexion, the anterior annulus of all segments at all loads showed higher mean pressure values than those during vertical compression, whereas the posterior annulus did not show higher mean values. During posterior extension, the anterior annulus of all segments showed lower mean pressure values than those during vertical compression, whereas the posterior annulus did not show lower mean pressure values. During lateral bending, the annulus of all segments showed higher mean pressure values than those during vertical compression. The posterior thoracic vertebra plays an important role in the motion of the upper thoracic vertebral segment and pressure distribution. During lateral bending, the concave side pressure of the annulus increases obviously, suggesting that asymmetrical force is a contributory factor for scoliosis progression.
Collapse
Affiliation(s)
- Zhao Meng
- Department of Orthopaedics, Children's Hospital of Hebei Province, No. 133, South Jianhua Street, Shijiazhuang, 050031, People's Republic of China.
| | - Chen Wang
- Department of Orthopaedics, Children's Hospital of Hebei Province, No. 133, South Jianhua Street, Shijiazhuang, 050031, People's Republic of China
| | - Xuzhao Guo
- Department of Orthopaedics, Children's Hospital of Hebei Province, No. 133, South Jianhua Street, Shijiazhuang, 050031, People's Republic of China
| | - Wei Chen
- Department of Traumatology Orthopaedics, The Third Affiliated Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China
| | - Wenyuan Ding
- Department of Spinal Surgery, The Third Affiliated Hospital of Hebei Medical University, Shijiazhuang, People's Republic of China
| |
Collapse
|
15
|
Pan F, Firouzabadi A, Reitmaier S, Zander T, Schmidt H. The shape and mobility of the thoracic spine in asymptomatic adults - A systematic review of in vivo studies. J Biomech 2018; 78:21-35. [PMID: 30100219 DOI: 10.1016/j.jbiomech.2018.07.041] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 07/27/2018] [Accepted: 07/31/2018] [Indexed: 12/29/2022]
Abstract
A comprehensive knowledge of the thoracic shape and kinematics is essential for effective risk prevention, diagnose and proper management of thoracic disorders and assessment of treatment or rehabilitation strategies as well as for in silico and in vitro models for realistic applications of boundary conditions. After an extensive search of the existing literature, this study summarizes 45 studies on in vivo thoracic kyphosis and kinematics and creates a systematic and detailed database. The thoracic kyphosis over T1-12 determined using non-radiological devices (34°) was relatively less than measured using radiological devices (40°) during standing. The majority of kinematical measurements are based on non-radiological devices. The thoracic range of motion (RoM) was greatest during axial rotation (40°), followed by lateral bending (26°), and flexion (21°) when determined using non-radiological devices during standing. The smallest RoM was identified during extension (13°). The lower thoracic level (T8-12) contributed more to the RoM than the upper (T1-4) and middle (T4-8) levels during flexion and lateral bending. During axial rotation and extension, the middle level (T4-8) contributed the most. Coupled motion was evident, mostly during lateral bending and axial rotation. With aging, the thoracic kyphosis increased by about 3° per decade, whereas the RoM decreased by about 5° per decade for all load directions. These changes with aging mainly occurred in the lower region (T6-12). The influence of sex on thoracic kyphosis and the RoM has been described as partly contradictory. Obesity was found to decrease the thoracic RoM. Studies comparing standing, sitting and lying reported the effect of posture as significant.
Collapse
Affiliation(s)
- Fumin Pan
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany
| | - Ali Firouzabadi
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany
| | - Sandra Reitmaier
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany
| | - Thomas Zander
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany
| | - Hendrik Schmidt
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany.
| |
Collapse
|
16
|
The rib cage stiffens the thoracic spine in a cadaveric model with body weight load under dynamic moments. J Mech Behav Biomed Mater 2018; 84:258-264. [PMID: 29852313 DOI: 10.1016/j.jmbbm.2018.05.019] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 02/12/2018] [Accepted: 05/09/2018] [Indexed: 01/23/2023]
Abstract
The thoracic spine presents a challenge for biomechanical testing. With more segments than the lumbar and cervical regions and the integration with the rib cage, experimental approaches to evaluate the mechanical behavior of cadaveric thoracic spines have varied widely. Some researchers are now including the rib cage intact during testing, and some are incorporating follower load techniques in the thoracic spine. Both of these approaches aim to more closely model physiological conditions. To date, no studies have examined the impact of the rib cage on thoracic spine motion and stiffness in conjunction with follower loads. The purpose of this research was to quantify the mechanical effect of the rib cage on cadaveric thoracic spine motion and stiffness with a follower load under dynamic moments. It was hypothesized that the rib cage would increase stiffness and decrease motion of the thoracic spine with a follower load. Eight fresh-frozen human cadaveric thoracic spines with rib cages (T1-T12) were loaded with a 400 N compressive follower load. Dynamic moments of ± 5 N m were applied in lateral bending, flexion/extension, and axial rotation, and the motion and stiffness of the specimens with the rib cage intact have been previously reported. This study evaluated the motion and stiffness of the specimens after rib cage removal, and compared the data to the rib cage intact condition. Range-of-motion and stiffness were calculated for the upper, middle, and lower segments of the thoracic spine. Range-of-motion significantly increased with the removal of the rib cage in lateral bending, flexion/extension, and axial rotation by 63.5%, 63.0%, and 58.8%, respectively (p < 0.05). Neutral and elastic zones increased in flexion/extension and axial rotation, and neutral zone stiffness decreased in axial rotation with rib cage removal. Overall, the removal of the rib cage increases the range-of-motion and decreases the stiffness of cadaveric thoracic spines under compressive follower loads in vitro. This study suggests that the rib cage should be included when testing a cadaveric thoracic spine with a follower load to optimize clinical relevance.
Collapse
|