1
|
Shihabi S, Chrcanovic BR. Clinical outcomes of tooth-supported monolithic zirconia vs. porcelain-veneered zirconia fixed dental prosthesis, with an additional focus on the cement type: a systematic review and meta-analysis. Clin Oral Investig 2023; 27:5755-5769. [PMID: 37626273 PMCID: PMC10560185 DOI: 10.1007/s00784-023-05219-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 08/15/2023] [Indexed: 08/27/2023]
Abstract
PURPOSE To compare the failure rates and the prevalence of technical complications between full-coverage tooth-supported monolithic zirconia (MZ) and porcelain-veneered zirconia (PVZ) fixed dental prosthesis, based on a systematic literature review. METHODS An electronic search was performed in three databases, supplemented by hand searching. Several statistical methods were used. RESULTS Seventy-four publications reported 6370 restorations (4264 PVZ; 2106 MZ; 8200 abutment teeth; 3549 patients), followed up until 152 months. A total of 216 prostheses failed, and survival was statistically significant different between groups. PVZ had higher occurrence of complications than MZ; the difference was especially greater for either minor or major chipping. The difference in prevalence of either minor or major chipping was statistically significant for PVZ prostheses between cementation with glass ionomer and adhesive resin cement (higher), adhesive resin and resin-modified glass ionomer cement (RMGIC, higher), and between RMGIC (higher) and glass ionomer cement. For MZ the difference was significant only for minor chipping between RMGIC (higher) and adhesive resin cement. Abutment teeth to PVZ prostheses more often lost vitality. Decementation was not observed with RMGIC. Air abrasion did not seem to clinically decrease the decementation risk. The 5-year difference in the occurrence of minor or major chipping between MZ and PVZ prostheses was statistically significant, but nor for catastrophic fracture. CONCLUSION Tooth-supported PVZ prostheses present higher failure and complication rates than MZ prosthesis. The difference in complications is striking when it comes to chipping. CLINICAL RELEVANCE Awareness of the outcome differences between different types of zirconia prostheses is important for clinical practice.
Collapse
Affiliation(s)
| | - Bruno Ramos Chrcanovic
- Department of Prosthodontics, Faculty of Odontology, Malmö University, Carl Gustafs Väg 34, 214 21 Malmö, Sweden
| |
Collapse
|
2
|
Lampl S, Gurunathan D, Krithikadatta J, Mehta D, Moodley D. Reasons for Failure of CAD/CAM Restorations in Clinical Studies: A Systematic Review and Meta-analysis. J Contemp Dent Pract 2023; 24:129-136. [PMID: 37272145 DOI: 10.5005/jp-journals-10024-3472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
AIM The systematic review presented herein was performed to descriptively analyze the causes for the failure of computer-aided design/computer-aided manufacture (CAD/CAM) restorations. The meta-analysis reported herein was performed to estimate long-term survival and success rates of CAD-CAM fabrications. MATERIALS AND METHODS Using the PICOS paradigm, a systematic search was carried out in the PubMed and Cochrane databases to identify randomized controlled trials (RCTs) and prospective observational studies reporting survival data for CAD/CAM restorations. After selecting studies with a predefined set of selection criteria, data from included prospective clinical studies and RCTs were used for a systematic review aimed at a descriptive analysis of factors associated with failure of CAD-CAM restorations. Data from the included prospective clinical studies were used for meta-analysis, wherein 5-year and 10-year survival and success rates were estimated using Poisson regression models. RESULTS The systematic review included data from 9 RCTs and 6 observational studies, which had a median follow-up of 36 months and 60 months, respectively. About 58 failures and 118 technical/ biological complications were noted in the included RCTs and 9 failures along with 58 technical/biological complications were noted in the prospective clinical studies. Poisson regression indicated an estimated 5-year and 10-year survival rates of 85.55-100 and 71-100, respectively. The estimated 5-year and 10-year success rates were 74.2-92.75 and 33.3-85.5, respectively. CONCLUSION Several technical and biological complications contribute to failure of CAD/CAM restorations. However, CAD/CAM restorations with routine chairside materials might have clinically meaningful success rates in the long term. CLINICAL SIGNIFICANCE The results presented herein indicate that optimal strategies for mitigation of biological and technical complications may augment the success of CAD/CAM fabrications in restorative dentistry. Studies aimed at identification of such strategies are needed to further enhance the long-term success rates of CAD/CAM restorations.
Collapse
Affiliation(s)
- Stephan Lampl
- Department of Paediatric Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
| | - Deepa Gurunathan
- Department of Paediatric Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India, Phone: +91 9994619386, e-mail:
| | - Jogikalmat Krithikadatta
- Department of Paediatric Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
| | - Deepak Mehta
- Department of Conservative Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, India; Department of Operative Dentistry, Tohoku University Graduate School of Dentistry, Tohoku University, Sendai, Japan
| | | |
Collapse
|
3
|
Rathmann F, Pohl M, Rammelsberg P, Bömicke W. Up to 10 years clinical performance of zirconia ceramic and metal-ceramic fixed partial dentures: A retrospective study. J Prosthet Dent 2022:S0022-3913(22)00692-8. [PMID: 36464507 DOI: 10.1016/j.prosdent.2022.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 11/03/2022] [Accepted: 11/03/2022] [Indexed: 12/02/2022]
Abstract
STATEMENT OF PROBLEM Completely veneered zirconia ceramic (ZC) fixed partial dentures (FPDs) have been reported to have a higher incidence of ceramic chipping than the standard metal-ceramic FPDs. However, data from comparative long-term studies are sparse. PURPOSE The purpose of this retrospective study was to compare the long-term survival, chipping-free survival, and success of ceramic-veneered high noble metal alloy (HN), base metal alloy (cobalt-chromium alloy) (CC), and ZC FPDs and to isolate risk factors for the incidence of failure, veneer chipping, and overall complications. MATERIAL AND METHODS Data from 289 study participants (58.7% women; mean age, 57.97 ±11.51 years) provided with a total of 400 FPDs comprising 197 (49.3%) HN FPDs, 121 (30.3%) CC FPDs, and 82 (20.5%) ZC FPDs fabricated from presintered 3 mol% yttria-stabilized zirconia (mean time of service, 6.85 ±3.25 years) were evaluated. Of these, 278 (69.5%) FPDs were provided by dentists and 122 (30.5%) by dental students. Five- and 10-year survival, chipping-free survival, and success rates were calculated using the Kaplan-Meier method and compared with the log-rank test. Risk factors were assessed using Cox regression analysis. The study was exploratory, so all P values were considered exploratory and descriptive. RESULTS The 5- and 10-year survival rates were 94.7% and 77.8% for HN, 93.7% and 81.2% for CC, and 92.9% and 53.3% for ZC FPDs, respectively, indicating no clear difference in survival among the framework materials. The 5- and 10-year chipping-free rates were 94.1% and 82.8% for HN, 96.1% and 78.9% for CC, and 82.6% and 62.2% for ZC FPDs, respectively, indicating a difference between HN and ZC, and CC and ZC restorations. The 5- and 10-year success rates were 83.7% and 55.3% for HN, 86.5% and 51.4% for CC, and 68.9% and 30.2% for ZC FPDs, respectively, indicating a difference between HN and ZC, and CC and ZC restorations. The Cox regression model indicated framework material as an influencing risk factor for success, and this influence persisted when chipping was investigated. Compared with zirconia, the use of a metal alloy reduced the risk of chipping or the occurrence of complications by up to one-third. CONCLUSIONS All FPDs showed high 5-year survival rates and acceptable 10-year survival rates with no strong differences among the materials. Higher success and chipping-free rates were observed for both HN and CC restorations compared with ZC restorations. Metal frameworks had a lower risk for complications or veneer chipping than zirconia frameworks.
Collapse
Affiliation(s)
- Friederike Rathmann
- Assistant Professor, Department of Prosthodontics, University Hospital Heidelberg, University of Heidelberg, Heidelberg, Germany
| | - Moritz Pohl
- Assistant Professor, Institute of Medical Biometry, University of Heidelberg, Heidelberg, Germany
| | - Peter Rammelsberg
- Director, Department of Prosthodontics, University Hospital Heidelberg, University of Heidelberg, Heidelberg, Germany
| | - Wolfgang Bömicke
- Associate Professor, Department of Prosthodontics, University Hospital Heidelberg, University of Heidelberg, Heidelberg, Germany.
| |
Collapse
|
4
|
Newaskar PS, Sonkesriya S, Singh R, Palekar U, Bagde H, Dhopte A. Evaluation and Comparison of Five-Year Survival of Tooth-Supported Porcelain Fused to Metal and All-Ceramic Multiple Unit Fixed Prostheses: A Systematic Review. Cureus 2022; 14:e30338. [PMID: 36407172 PMCID: PMC9663878 DOI: 10.7759/cureus.30338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023] Open
Abstract
The prosthesis must have good survival despite being functional for at least 5-10 years. This makes sure that the replacement of missing teeth does not become a repeated expense. Of 579 identified articles, 15 met the inclusion criteria for systematic review. Missing teeth replacement materials are divided into two groups: porcelain fused to metal and all ceramics. Data related to survival rates as well as the most common mode of failure is observed from both groups. It was observed that porcelain fused to metal prostheses had an approximately 99.5% survival rate and an approximately 92% survival rate for all-ceramic tooth-supported prostheses after five years of insertion. Porcelain-fused-to-metal (PFM) prostheses had a better survival rate after five years of insertion as compared to all-ceramic prostheses. Porcelain fused to metal should be the treatment of choice for dentists and patients when missing teeth need to be fixed.
Collapse
Affiliation(s)
- Prabha Shakya Newaskar
- Department of Prosthodontics, Rural Dental College, Pravara Institute of Medical Sciences - Deemed University (PIMS-DU), Loni, IND
| | - Subhash Sonkesriya
- Department of Prosthodontics, Government Dental College and Hospital, Indore, IND
| | - Rashmi Singh
- Department of Prosthodontics, Mansarovar Dental College, Hospital and Research Centre, Bhopal, IND
| | - Umesh Palekar
- Department of Prosthodontics, Rural Dental College, Pravara Institute of Medical Sciences - Deemed University (PIMS-DU), Loni, IND
| | - Hiroj Bagde
- Periodontology, Rama Dental College and Research Centre, Kanpur, IND
| | - Ashwini Dhopte
- Oral Medicine and Radiology, Rama Dental College and Research Centre, Kanpur, IND
| |
Collapse
|
5
|
Posterior ceramic versus metal restorations: A systematic review and meta-analysis. Dent Mater 2022; 38:1623-1632. [PMID: 36038401 DOI: 10.1016/j.dental.2022.08.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 08/09/2022] [Accepted: 08/18/2022] [Indexed: 01/13/2023]
Abstract
OBJECTIVES The goal of this systemic review and meta-analysis was to evaluate the longevity of indirect adhesively-luted ceramic compared to conventionally cemented metal single tooth restorations. DATA Randomized controlled trials (RCT) investigating indirect adhesively-luted ceramic restorations compared to metal or metal-based cemented restorations in permanent posterior teeth. SOURCES Three electronic databases (PubMed, CENTRAL (Cochrane) and Embase) were screened. No language or time restrictions were applied. Study selection, data extraction and quality assessment were done in duplicate. Risk of Bias and level of evidence was graded using Risk of Bias 2.0 tool and Grade Profiler 3.6. RESULTS A total of 3056 articles were found by electronic databases. Finally, four RCTs were selected. Overall, 443 restorations of which 212 were adhesively-luted ceramic restorations and 231 conventionally cemented metal restorations have been placed in 314 patients (age: 22-72 years). The highest annual failure rates were found for ceramic restorations ranging from 2.1% to 5.6%. Lower annual failure rates were found for metal (gold) restorations ranging from 0% to 2.1%. Meta-analysis could be performed for adhesively-luted ceramic vs. conventionally cemented metal restorations. Conventionally cemented metal restoration showed a significantly lower failure rate than adhesively-luted ceramic ones (visual-tactile assessment: Risk Ratio (RR)[95%CI]=0.31[0.16,0.57], low level of evidence). Furthermore, all studies showed a high risk of bias. CONCLUSION Conventionally cemented metal restorations revealed significantly lower failure rates compared to adhesively-luted ceramic ones, although the selected sample was small and with medium follow-up periods with high risks of bias.
Collapse
|
6
|
Comparative Assessment of the Functional Parameters for Metal-Ceramic and All-Ceramic Teeth Restorations in Prosthetic Dentistry-A Literature Review. BIOLOGY 2022; 11:biology11040556. [PMID: 35453755 PMCID: PMC9024664 DOI: 10.3390/biology11040556] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 03/27/2022] [Accepted: 03/31/2022] [Indexed: 12/16/2022]
Abstract
Simple Summary In the last decades, the science and technology of all-ceramic teeth restorations witnessed the fastest-growing field of restorative materials in research and development for fixed prosthodontics. Due to their properties, characterized by a high level of biocompatibility, excellent optical properties, and high fracture resistance, all-ceramic material can also be used in the posterior areas of the dental arches. However, metal-ceramic fixed partial dentures are still perceived as the golden standard for those restorations, thanks to the positive clinical outcomes. Irrespective of the materials of which fixed partial dentures are performed, their success rates depend on the expected outcome and on how they perform in the oral environment. Such conditions of failure restorations may include biological factors (i.e., secondary decay, loss of vitality, periodontal disease, or abutment fracture) or technical factors (i.e., chipping, ceramic fracture, framework fracture, or loss of retention). Our aim is to provide the current evidence for the efficacy of metal-ceramics and all-ceramics in the treatment of multiple posterior edentulous spaces. Moreover, we aim to compare the survival rates of metal-ceramic and all-ceramic fixed partial dentures in terms of functionality and biocompatibility in all the aforementioned clinical situations. Our results have shown that all all-ceramic systems, especially densely sintered zirconia and reinforced glass ceramics, have a promising future to satisfy both practitioners and patients. However, technical and biological complications need to be taken into account when planning multi-unit fixed partial dentures for the posterior areas. Abstract The metal-ceramic fixed partial prosthesis is the golden standard for posterior tooth restorations. Following the demands of patients and clinicians for metal-free restorations, all-ceramic materials were developed as they offer an adequate alternative with better optical qualities and good mechanical properties. This study aims to carry out a bibliographic review to assess the survival rate and the biological and technical complications of all-ceramic and metal-ceramic fixed partial dentures. An electronic search for articles in the English language literature was performed using PubMed (MEDLINE). This literature review focused on research studies between 2010 and 2020 that performed clinical studies on tooth-supported fixed partial dentures with a mean follow-up of at least 3 years. All the studies, which analyzed the survival and complications of tooth-supported fixed partial dentures, were included. Thus, 14 studies reporting on 756 all-ceramic and 160 metal-ceramic fixed partial dentures met the inclusion criteria. A comparative analysis was carried out based on all the data existing in the studies included in this review. The metal-ceramic fixed partial dentures showed survival rates of 95% to 100% at 3-, 5-, and 10-year follow-up periods. Zirconia fixed partial dentures were reported to have survival rates of 81% to 100% at 3-, 5-, 9-, 10-year follow-up evaluations. The reinforced glass-ceramic fixed partial dentures showed survival rates of 70% to 93.35% at 5 years, while the alumina FPDs showed a survival rate of 68% at 3 years follow-up. The incidence of caries and loss of vitality were reported as higher for all-ceramic prostheses as compared to the metal-ceramic ones. A significant framework fracture was reported for glass-infiltrated alumina fixed partial dentures in comparison to metal-ceramic fixed partial dentures. All-ceramic and metal-ceramic restorations showed similar survival rates after 3 years, although all-ceramic restorations have problems with technical complications such as chipping, which can lead to framework fractures over time.
Collapse
|
7
|
Matta RE, Eitner S, Stelzer SP, Reich S, Wichmann M, Berger L. Ten-year clinical performance of zirconia posterior fixed partial dentures. J Oral Rehabil 2021; 49:71-80. [PMID: 34717003 DOI: 10.1111/joor.13276] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 08/15/2021] [Accepted: 09/23/2021] [Indexed: 12/01/2022]
Abstract
BACKGROUND With the constantly increasing demand for metal-free solutions in dental therapy, numerous ceramic restorations have found their way into everyday clinical practice, but long-term clinical data are limited. OBJECTIVE The aim of this prospective clinical study was to evaluate three- and four-unit fixed partial dentures in the posterior region made of zirconium dioxide frameworks veneered with feldspathic porcelain after 10 years in clinical use. METHODS Based on the two studies published in 2009 and 2012, in which the all-ceramic FDPs were evaluated after 3 and 5 years of function, a clinical evaluation of a total of 17 restorations after 10 years with regard to their condition and long-term stability was carried out in the course of this study. The restorations were fabricated using feldspathic ceramic-veneered, yttria-stabilised, tetragonal zirconium dioxide as the framework material. The data collection was based on modified CDA criteria and included, for example, the shape, shade, surface condition and the success and survival rates of the restorations. RESULTS The all-ceramic prostheses embodied excellent biocompatibility and colour reproduction. As a result of an increased incidence of chipping fractures, the success rate was 60%. The survival rate, however, was 88.2%, as 2 of the 17 restorations were lost. CONCLUSION All-ceramic concepts for FDP constructions in the posterior region achieved satisfactory results in terms of durability after 10 years. The main problem was chipping, as has been generally recognised. Nevertheless, the materials were characterised by excellent aesthetics and biocompatibility, which ultimately makes them a good alternative to conventional restorative options. TRIAL REGISTRATION This study is registered in DRKS-German Clinical Trials Register with the register number DRKS00021743.
Collapse
Affiliation(s)
- Ragai-Edward Matta
- Department of Prosthodontics, Erlangen University Hospital, Erlangen, Germany
| | - Stephan Eitner
- Department of Prosthodontics, Erlangen University Hospital, Erlangen, Germany
| | | | - Sven Reich
- Department of Prosthodontics and Biomaterials, Faculty of Medicine, Centre of Implantology, RWTH University Hospital, Aachen, Germany
| | - Manfred Wichmann
- Department of Prosthodontics, Erlangen University Hospital, Erlangen, Germany
| | - Lara Berger
- Department of Prosthodontics, Erlangen University Hospital, Erlangen, Germany
| |
Collapse
|
8
|
Saravi B, Vollmer A, Hartmann M, Lang G, Kohal RJ, Boeker M, Patzelt SBM. Clinical Performance of CAD/CAM All-Ceramic Tooth-Supported Fixed Dental Prostheses: A Systematic Review and Meta-Analysis. MATERIALS 2021; 14:ma14102672. [PMID: 34065202 PMCID: PMC8161295 DOI: 10.3390/ma14102672] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 05/16/2021] [Accepted: 05/18/2021] [Indexed: 12/29/2022]
Abstract
Although CAD/CAM ceramics present a promising alternative to metal-ceramic fixed dental prostheses, little is known about their mid- and long-term clinical performance. This systematic review aims to estimate the survival and success rates and describes the underlying complication characteristics for CAD/CAM tooth-supported zirconia- and lithium disilicate-based fixed dental prostheses (FDPs). We systematically searched MEDLINE and Web of Science to find relevant prospective studies with a follow-up of at least one year. We estimated pooled 1-, 5-, and 10-year survival and success rates by combining the collected data in a Poisson regression model. Descriptive statistics were conducted to evaluate the distribution of failures and complications in the included studies. Risk of bias for the included studies was assessed with an adapted checklist for single-arm trials. Pooled estimated 1-, 5-, and 10-year survival rates ranged from 93.80% to 94.66%, 89.67% to 91.1%, and 79.33% to 82.20%, respectively. The corresponding success rates excluding failures, but including any other types of intervention were 94.53% to 96.77%, 90.89% to 94.62%, and 81.78% to 89.25%. Secondary caries was the most frequent cause of failure, followed by chipping of the veneering. The most common cause of complication excluding failures but requiring intervention was chipping of the veneering. Risk of bias was generally acceptable for the included studies, with seven studies associated with low risk of bias, eight studies with a moderate risk of bias, and three studies with serious risk of bias. The current meta-analysis on CAD/CAM-supported FDPs revealed satisfying survival and success rates for up to 10 years of exposure. More prospective studies focusing on long-term performance are needed to strengthen the evidence currently available in the literature.
Collapse
Affiliation(s)
- Babak Saravi
- Medical Center—University of Freiburg, Department of Orthopedics and Trauma Surgery, Faculty of Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany;
- Correspondence:
| | - Andreas Vollmer
- Department of Oral and Maxillofacial Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany;
| | - Maja Hartmann
- Private Practice, Kantstraße 10, 60316 Frankfurt am Main, Germany;
| | - Gernot Lang
- Medical Center—University of Freiburg, Department of Orthopedics and Trauma Surgery, Faculty of Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany;
| | - Ralf-Joachim Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany; (R.-J.K.); (S.B.M.P.)
| | - Martin Boeker
- Medical Center—University of Freiburg, Institute of Medical Biometry and Medical Statistics, Faculty of Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany;
| | - Sebastian B. M. Patzelt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany; (R.-J.K.); (S.B.M.P.)
- Private Practice, Am Dorfplatz 3, 78658 Zimmern o.R., Germany
| |
Collapse
|
9
|
Matta RE, Motel C, Kirchner E, Stelzer SP, Adler W, Wichmann M, Berger L. Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years. BMC Oral Health 2020; 20:345. [PMID: 33256686 PMCID: PMC7708209 DOI: 10.1186/s12903-020-01336-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 11/18/2020] [Indexed: 11/18/2022] Open
Abstract
Background The abrasion behavior of various ceramics is rarely investigated, though it is relevant for the clinical success of such restorations. The aim of this in vivo study was to evaluate the wear of feldspathic-ceramic-veneered zirconium oxide frameworks over a period of at least 10 years. Methods The abrasion behavior of 15 bridge constructions from 15 different participants was examined after a period of 3, 5, and 10 years using plaster models, which were then subjected to a scanning process on the Atos II industrial scanner and digitized for three-dimensional evaluation of the abrasion by the corresponding software (ATOS Professional 7.6). The individual post-examination models were compared to the baseline model and deviations calculated in the sense of the largest, punctual loss of material in millimeters (“minimal distance”), the average abrasion in millimeters (“mean distance”), and the volume decrease in cubic millimeters (“integrated distance”). Statistical analyses were performed using the Wilcoxon sign rank test or mixed regression models. Multiple testing was considered by Benjamini-Hochberg correction. The significance level was set at 0.05. Results We found steadily increasing wear of the ceramic. The average volume decrease was significant (P < 0.001) at 3 years and 10 years (− 3.25 mm3 and − 8.11 mm3, respectively). Conclusions The results of this study indicate that the rate of volume loss in feldspathic-ceramic-veneered zirconia frameworks in the posterior region increases significantly over time. An increasing frequency of parameters was observed, particularly in the second half of the study period. However, the use of this class of materials can be considered clinically acceptable. Trial registration This study is registered in DRKS - German Clinical Trials Register with the register number DRKS00021743. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00021743
Collapse
Affiliation(s)
- Ragai-Edward Matta
- Department of Prosthodontics, Erlangen University Hospital, Glueckstrasse 11, 91054, Erlangen, Germany.
| | - Constantin Motel
- Department of Prosthodontics, Erlangen University Hospital, Glueckstrasse 11, 91054, Erlangen, Germany
| | - Elena Kirchner
- Department of Prosthodontics, Erlangen University Hospital, Glueckstrasse 11, 91054, Erlangen, Germany
| | - Simon Paul Stelzer
- Zahnarztpraxis Haidhausen Dr. Hans-Rudolf Kurpiers und Christian Pollok, Weißenburger Platz 8, 81667, Munich, Germany
| | - Werner Adler
- Department of Medical Informatics, Biometry and Epidemiology, Friedrich-Alexander-University of Erlangen Nuremberg, Waldstr. 6, 91054, Erlangen, Germany
| | - Manfred Wichmann
- Department of Prosthodontics, Erlangen University Hospital, Glueckstrasse 11, 91054, Erlangen, Germany
| | - Lara Berger
- Department of Prosthodontics, Erlangen University Hospital, Glueckstrasse 11, 91054, Erlangen, Germany
| |
Collapse
|
10
|
Ko KH, Park CJ, Cho LR, Huh YH. Effect of core design on fracture resistance of zirconia-lithium disilicate anterior bilayered crowns. J Adv Prosthodont 2020; 12:181-188. [PMID: 32879707 PMCID: PMC7449823 DOI: 10.4047/jap.2020.12.4.181] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 05/08/2020] [Accepted: 05/22/2020] [Indexed: 12/03/2022] Open
Abstract
PURPOSE The effect of core design on the fracture resistance of zirconia-lithium disilicate (LS2) bilayered crowns for anterior teeth is evaluated by comparing with that of metal-ceramic crowns. MATERIALS AND METHODS Forty customized titanium abutments for maxillary central incisor were prepared. Each group of 10 units was constructed using the same veneer form of designs A and B, which covered labial surface to approximately one third of the incisal and cervical palatal surface, respectively. LS2 pressed-on-zirconia (POZ) and porcelain-fused-to-metal (PFM) crowns were divided into “POZ_A,” “POZ_B,” “PFM_A,” and “PFM_B” groups, and 6000 thermal cycles (5/55℃) were performed after 24 h storage in distilled water at 37℃. All specimens were prepared using a single type of self-adhesive resin cement. The fracture resistance was measured using a universal testing machine. Failure mode and elemental analyses of the bonding interface were performed. The data were analyzed using Welch's t-test and the Games-Howell exact test. RESULTS The PFM_B (1376. 8 ± 93.3 N) group demonstrated significantly higher fracture strength than the PFM_A (915.8 ± 206.3 N) and POZ_B (963.8 ± 316.2 N) groups (P<.05). There was no statistically significant difference in fracture resistance between the POZ_A (1184.4 ± 319.6 N) and POZ_B groups (P>.05). Regardless of the design differences of the zirconia cores, fractures involving cores occurred in all specimens of the POZ groups. CONCLUSION The bilayered anterior POZ crowns showed different fracture resistance and fracture pattern according to the core design compared to PFM.
Collapse
Affiliation(s)
- Kyung-Ho Ko
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Chan-Jin Park
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Lee-Ra Cho
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Yoon-Hyuk Huh
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| |
Collapse
|
11
|
Fatigue degradation of bilayered ceramic structures under different biaxial loading schemes. J Mech Behav Biomed Mater 2020; 104:103651. [PMID: 32174409 DOI: 10.1016/j.jmbbm.2020.103651] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 01/21/2020] [Accepted: 01/21/2020] [Indexed: 11/22/2022]
|
12
|
Kim JH, Ko KH, Huh YH, Park CJ, Cho LR. Effects of the Thickness Ratio of Zirconia-Lithium Disilicate Bilayered Ceramics on the Translucency and Flexural Strength. J Prosthodont 2019; 29:334-340. [PMID: 31876065 DOI: 10.1111/jopr.13136] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/20/2019] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To determine the effects of the total thickness and core/veneer thickness ratio of bilayered ceramics on their three-point flexural strength and translucency. MATERIALS AND METHODS Two groups of specimens were prepared with two different total thicknesses, 1.0 mm and 0.6 mm. These groups were divided into five and three subgroups with ten specimens each, respectively, having different core/veneer thickness ratios. Lithium disilicate was pressed on the zirconia surface using the "lost-wax technique." The translucency and three-point flexural strength were measured, and a one-way analysis of variance test (p < 0.05) was performed to determine whether the translucency and three-point flexural strength were affected by the total thickness and core/veneer thickness ratio of the specimens. RESULTS For the same total thickness, translucency decreased with a increase in the zirconia core proportion (p < 0.001). For the same core/veneer ratio, the translucency decreased with an increase in the total thickness (p < 0.001). If the zirconia thickness was less than half of the total thickness, the bilayered ceramic specimens containing zirconia cores and monolithic lithium disilicate specimens exhibited a similar translucency. The three-point flexural strength increased with the increasing proportion of zirconia; however, it did not change significantly with the total thickness. However, for the same total thickness, the flexural strengths of the bilayered ceramics were higher than those of the monolithic specimens. CONCLUSIONS At the same total thickness, increasing the zirconia core thickness decreased the translucency and increased the three-point flexural strength. Bilayered ceramic specimens with low zirconia ratios exhibited translucency similar to that of monolithic lithium disilicate ceramic but a higher flexural strength.
Collapse
Affiliation(s)
- Jong-Hoi Kim
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Kyung-Ho Ko
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Yoon-Hyuk Huh
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Chan-Jin Park
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Lee-Ra Cho
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| |
Collapse
|
13
|
Fifteen-year outcome of three-unit fixed dental prostheses made from monolithic lithium disilicate ceramic. J Dent 2019; 89:103178. [DOI: 10.1016/j.jdent.2019.08.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 07/23/2019] [Accepted: 08/02/2019] [Indexed: 11/22/2022] Open
|
14
|
Al-Akhali M, Kern M, Elsayed A, Samran A, Chaar MS. Influence of thermomechanical fatigue on the fracture strength of CAD-CAM-fabricated occlusal veneers. J Prosthet Dent 2019; 121:644-650. [DOI: 10.1016/j.prosdent.2018.07.019] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 07/22/2018] [Accepted: 07/23/2018] [Indexed: 11/16/2022]
|
15
|
Teichmann M, Göckler F, Rückbeil M, Weber V, Edelhoff D, Wolfart S. Periodontal outcome and additional clinical quality criteria of lithium-disilicate restorations (Empress 2) after 14 years. Clin Oral Investig 2018; 23:2153-2164. [PMID: 30276515 DOI: 10.1007/s00784-018-2649-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Accepted: 09/20/2018] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To evaluate the clinical quality of tooth-supported crowns (SCs), implant-supported crowns (ISCs), and fixed dental prosthesis (FDPs) made of a lithium-disilicate glass-ceramic framework material (IPS Empress 2, Ivoclar Vivadent) after long-term use. MATERIALS AND METHODS Between 1997 and 1999, 184 restorations (106 SCs, 32 ISCs, 33 FDPs, 13 diverse restorations) were placed in 73 patients. In 2012/2013, all patients with functioning restorations were invited to participate in a clinical follow-up examination. To investigate the clinical quality, modified California Dental Association (CDA) criteria, periodontal health, and the patient's opinion were evaluated. RESULTS After 14 years on average, 50 restorations were available for evaluation of the CDA criteria and the patient's opinion, and 24 restorations were available for the periodontal health evaluation. Surface, color, anatomic shape, and margin integrity were considered to be in the range of excellence in 54, 78, 96, and 88%, respectively. There were no unacceptable defects. Most patients (64%) were still entirely satisfied with their restorations. Mean probing depths were significantly higher on teeth with tooth-supported Empress 2 restorations than on control teeth (p = 0.0401). No significant relationship was found between surface quality and plaque accumulation (p = 0.9450, generalized linear mixed model) or between surface quality and periodontal probing ≥ 4 mm (p = 0.4184, generalized linear mixed model). CONCLUSIONS The clinical quality of the Empress 2 restorations that had survived 14 years on average was totally satisfactory with regard to esthetics, design, and patient's opinion. The periodontal health of all-ceramic restored teeth requires further investigation. CLINICAL SIGNIFICANCE The practitioner's choice of dental materials is based, at best, on long-term experience. With diminishing concerns about the clinical longevity of all-ceramic restorations, the grading of clinical quality based on esthetics, design, periodontal response, and patients' opinions could, nowadays, serve as a measure for the efficiency of dental ceramic.
Collapse
Affiliation(s)
- Maren Teichmann
- Department of Prosthodontics and Biomaterials, Center of Implantology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany.
| | - Fabian Göckler
- Department of Prosthodontics and Biomaterials, Center of Implantology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Marcia Rückbeil
- Department of Medical Statistics, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Volker Weber
- Dental laboratory Impladent GmbH, Kullenhofstraße 30, 52074, Aachen, Germany
| | - Daniel Edelhoff
- Department of Prosthodontics, School of Dentistry, Ludwig-Maximilians-University, Goethestr. 70, 80336, Munich, Germany
| | - Stefan Wolfart
- Department of Prosthodontics and Biomaterials, Center of Implantology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany
| |
Collapse
|
16
|
Sailer I, Balmer M, Hüsler J, Hämmerle CHF, Känel S, Thoma DS. 10-year randomized trial (RCT) of zirconia-ceramic and metal-ceramic fixed dental prostheses. J Dent 2018; 76:32-39. [DOI: 10.1016/j.jdent.2018.05.015] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 05/22/2018] [Accepted: 05/25/2018] [Indexed: 11/26/2022] Open
|
17
|
Ten-year survival and chipping rates and clinical quality grading of zirconia-based fixed dental prostheses. Clin Oral Investig 2018. [DOI: 10.1007/s00784-018-2378-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
18
|
Miura S, Kasahara S, Yamauchi S, Okuyama Y, Izumida A, Aida J, Egusa H. Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study. Clin Oral Investig 2017; 22:697-706. [DOI: 10.1007/s00784-017-2142-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Accepted: 05/29/2017] [Indexed: 12/21/2022]
|
19
|
Teichmann M, Göckler F, Weber V, Yildirim M, Wolfart S, Edelhoff D. Ten-year survival and complication rates of lithium-disilicate (Empress 2) tooth-supported crowns, implant-supported crowns, and fixed dental prostheses. J Dent 2017; 56:65-77. [DOI: 10.1016/j.jdent.2016.10.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 10/22/2016] [Accepted: 10/28/2016] [Indexed: 10/20/2022] Open
|
20
|
Outcome of zirconia partial fixed dental prostheses made by predoctoral dental students: A clinical retrospective study after 3 to 7 years of clinical service. J Prosthet Dent 2016; 116:40-6. [DOI: 10.1016/j.prosdent.2015.10.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Revised: 10/14/2015] [Accepted: 10/15/2015] [Indexed: 11/21/2022]
|
21
|
Merk S, Wagner C, Stock V, Schmidlin PR, Roos M, Eichberger M, Stawarczyk B. Retention Load Values of Telescopic Crowns Made of Y-TZP and CoCr with Y-TZP Secondary Crowns: Impact of Different Taper Angles. MATERIALS 2016; 9:ma9050354. [PMID: 28773477 PMCID: PMC5503027 DOI: 10.3390/ma9050354] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 04/28/2016] [Accepted: 05/06/2016] [Indexed: 11/24/2022]
Abstract
This study aimed to examine and compare the retention load values (RL) of different telescopic crown assemblies (Y-TZP and CoCr primary crowns with electroformed and Y-TZP secondary crowns each) with three different taper angles (0°, 1° and 2°). Thirty Y-TZP primary crowns with electroformed gold copings (Z/G group) and Y-TZP secondary crowns (Z/Z group) and 30 CoCr primary crowns with electroformed gold copings (C/G group) and Y-TZP secondary crowns (C/Z group), each with taper angles of 0°, 1° and 2°, were fabricated, respectively. With the exception of the electroformed gold copings, all specimens were Computer-Aided-Design/Computer-Aided-Manufacturing (CAD/CAM)-milled, then sintered and afterwards manually adapted. In order to stabilize the gold copings, they were fixed in a tertiary structure. The secondary crowns were constructed with a hook, which ensured self-alignment with an upper chain. Afterwards, 20 pull-off test cycles were performed in a universal testing machine under artificial saliva and after weighing the secondary crowns with a 5 kg object for 20 s. Data were analyzed by one-way and two-way Analysis of Variance (ANOVA). C/Z with 1° showed higher (p = 0.009) RL than 0° and 2° tapers. C/G at 1° also showed higher (p = 0.001) RL than at tapers of 0° and 2°. Z/G and C/G at 0° showed lower RL than Z/Z and C/Z (p < 0.001). Primary crowns had no impact on the 0° group. Z/G showed lower RL as compared to C/Z within the 1° group (p = 0.007) and Z/Z in the 2° group (p = 0.006). The primary crown material had no influence on RL. Electroformed copings showed lower RL. Further investigations for 1° as well as for the long-term performance after thermomechanical aging are necessary.
Collapse
Affiliation(s)
- Susanne Merk
- Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich, Goethestrasse 70, Munich 80336, Germany.
| | - Christina Wagner
- Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich, Goethestrasse 70, Munich 80336, Germany.
| | - Veronika Stock
- Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich, Goethestrasse 70, Munich 80336, Germany.
| | - Patrick R Schmidlin
- Clinic of Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland.
| | - Malgorzata Roos
- Division of Biostatistics, Epidemiology Biostatistics and Prevention Institute, University of Zurich, Hirschengraben 84, Zurich 8001, Switzerland.
| | - Marlis Eichberger
- Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich, Goethestrasse 70, Munich 80336, Germany.
| | - Bogna Stawarczyk
- Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich, Goethestrasse 70, Munich 80336, Germany.
| |
Collapse
|
22
|
Ioannidis A, Bindl A. Clinical prospective evaluation of zirconia-based three-unit posterior fixed dental prostheses: Up-to ten-year results. J Dent 2016; 47:80-5. [PMID: 26844399 DOI: 10.1016/j.jdent.2016.01.014] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2015] [Revised: 01/08/2016] [Accepted: 01/30/2016] [Indexed: 10/22/2022] Open
Abstract
OBJECTIVES Only a few studies exist, which assess the clinical long-term behavior of all-ceramic FDPs in the posterior region. The aim of the present prospective clinical study was to evaluate the clinical performance of posterior three-unit FDPs manufactured from Y-TZP after a service period up to 10 years. METHODS 55 patients received 59 three-unit FDPs in the posterior region of the maxilla or mandible. Abutment teeth were prepared and full-arch impressions were taken. Definitive casts were fabricated and optically scanned. Frameworks were fabricated with computer-aided design (CAD) and manufacturing (CAM) technology. Y-TZP frameworks were veneered and adhesively luted to the abutment teeth. Baseline and follow-up examinations (service time: ≥ 48 months) were recorded by applying modified United States Public Health Services (USPHS) rating criteria. Cumulative survival rate was analyzed with Kaplan-Meier. Percentage of biological and technical complication was calculated. RESULTS Fifty-three patients with 57 FDPs attended the last follow-up visit and a mean observation period of the remaining was 6.3 ± 1.9 years was calculated. Biological complications occurred in 17.5%, technical complications in 28% of the FDPs. The 10-year cumulative survival rate amounted 85.0%. Three FDPs failed to survive, two due to a root fracture of the abutment tooth and one due to secondary caries. CONCLUSIONS Three-unit FDPs made from Y-TZP, veneered with ceramic offer a treatment option with a high rate of chipping. However, the manufacturing processes nowadays are modified in order to avoid this complication. CLINICAL SIGNIFICANCE The results of the present investigation suggest that three-unit Y-TZP posterior FDPs may are a possible treatment option. However, a high rate of chipping can be expected.
Collapse
Affiliation(s)
- Alexis Ioannidis
- Clinic of Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland.
| | - Andreas Bindl
- Clinic of Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland.
| |
Collapse
|