1
|
Karevan Y, Eldafrawy M, Herman R, Sanchez C, Sadoun M, Mainjot A. Do all ceramic and composite CAD-CAM materials exhibit equal bonding properties to implant Ti-base materials? An Interfacial Fracture Toughness Study. Dent Mater 2024; 40:1524-1533. [PMID: 39107223 DOI: 10.1016/j.dental.2024.07.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 07/19/2024] [Accepted: 07/23/2024] [Indexed: 08/09/2024]
Abstract
OBJECTIVES To compare the interfacial fracture toughness (IFT) with or without aging, of four different classes of CAD-CAM ceramic and composite materials bonded with self-adhesive resin cement to titanium alloy characteristic of implant abutments. METHODS High translucent zirconia (Katana; KAT), lithium disilicate-based glass-ceramic (IPS. emax.CAD; EMX), polymer-infiltrated ceramic network material (PICN) (Vita Enamic; ENA), and dispersed filler composite (Cerasmart 270; CER) were cut into equilateral triangular prisms and bonded to titanium prisms with identical dimensions using Panavia SA Cement Universal. The surfaces were pretreated following the manufacturers' recommendations and developed interfacial area ratio (Sdr) of the pretreated surfaces was measured. IFT was determined using the Notchless Triangular Prism test in a water bath at 36 °C before and after thermocycling (10,000 cycles) (n = 40 samples/material). RESULTS IFT of the materials ranged from 0.80 ± 0.25 to 1.10 ± 0.21 MPa.m1/2 before thermocycling and from 0.71 ± 0.24 to 1.02 ± 0.25 MPa.m1/2 after thermocycling. There was a statistical difference between IFT of CER and the two top performers in each scenario: KAT and EMX before aging, and KAT and ENA after aging. Thermocycling significantly decreased IFT of EMX. The Weibull modulus of IFT was similar for all materials and remained so after thermocycling. Sdr measurements revealed that ENA (7.60)>Ti (4.97)>CER (2.85)>KAT (1.09)=EMX (0.96). SIGNIFICANCE Dispersed filler CAD-CAM composite showed lower performance than the other materials. Aging only affected IFT of Li-Si glass-ceramic, whereas zirconia and PICN performed equally well, probably due to their chemical bonding potential and surface roughness respectively.
Collapse
Affiliation(s)
- Yousef Karevan
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège), Liège, Belgium
| | - Maher Eldafrawy
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège), Liège, Belgium
| | - Raphael Herman
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège), Liège, Belgium
| | - Christelle Sanchez
- Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège Hospital (CHU), Liège, Belgium
| | | | - Amélie Mainjot
- Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège Hospital (CHU), Liège, Belgium.
| |
Collapse
|
2
|
Aydin N, Celik Oge S, Guney O, Okbaz O, Sertdemir Y. A Comparison of the Shear Bond Strength between a Luting Composite Resin and Both Machinable and Printable Ceramic-Glass Polymer Materials. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4697. [PMID: 39410268 PMCID: PMC11477453 DOI: 10.3390/ma17194697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Revised: 09/17/2024] [Accepted: 09/19/2024] [Indexed: 10/20/2024]
Abstract
This study aims to compare the shear bond strength (SBS) and Weibull characteristics between a luting composite resin and both printable and two different machinable ceramic-glass polymer materials. A total of 36 substrates were prepared, with 12 in each group. Printable substrates (12 mm × 12 mm × 2 mm) were printed by using permanent crown resin (3D-PR). Machinable substrates were obtained from Cerasmart 270 (CS) and Vita Enamic (VE) blocks (2 mm in thickness). The bonding surfaces of substrates were polished and airborne abraded (50 µm Al2O3). A self-adhesive luting composite resin (RelyX U200, 3M ESPE, St. Paul, MN, USA, SLC) was applied on substrates with the help of a cylindrical (Ø3 × 3 mm) mold. The SBS test was conducted using a universal test machine. The SBSs of three materials were compared using a one-way analysis of variance (ANOVA) (α = 0.05). The Weibull modulus was calculated for each material. The Kruskal-Wallis and chi-square tests were carried out for the failure mode analysis. There was no significant difference between the SBSs of the three materials (p = 0.129). The Weibull modulus was 3.76 for the 3D-PR, 4.22 for the CS, and 6.52 for the VE group. Statistical analysis showed no significant difference between the failure modes of the groups (p = 0.986). Mixed-failure fractures were predominantly observed in all three groups. The results show that the SBS of the SLC to printable 3D-PR is comparable to that of CS and VE material. Failure modes of printable 3D-PR show similar results with two different machinable ceramic-glass polymers.
Collapse
Affiliation(s)
- Nazli Aydin
- Department of Prosthodontics, Faculty of Dentistry, Cukurova University, Adana 01250, Turkey;
- The Abdi Sutcu Vocational School of Health Services, Cukurova University, Adana 01790, Turkey
| | - Selin Celik Oge
- Department of Prosthodontics, Faculty of Dentistry, Cukurova University, Adana 01250, Turkey;
| | - Ogulcan Guney
- Faculty of Dentistry, Cukurova University, Adana 01250, Turkey; (O.G.); (O.O.)
| | - Onur Okbaz
- Faculty of Dentistry, Cukurova University, Adana 01250, Turkey; (O.G.); (O.O.)
| | - Yasar Sertdemir
- Department of Biostatistics and Medical Informatics, Faculty of Medicine, Cukurova University, Adana 01790, Turkey;
| |
Collapse
|
3
|
Antoniou I, Mourouzis P, Dionysopoulos D, Pandoleon P, Tolidis K. Influence of Immediate Dentin Sealing on Bond Strength of Resin-Based CAD/CAM Restoratives to Dentin: A Systematic Review of In Vitro Studies. Biomimetics (Basel) 2024; 9:267. [PMID: 38786477 PMCID: PMC11118030 DOI: 10.3390/biomimetics9050267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 04/22/2024] [Accepted: 04/26/2024] [Indexed: 05/25/2024] Open
Abstract
Immediate dentin sealing (IDS) is a method of improving the bond strength of indirect dental restorative materials to dentin and belongs to the biomimetic protocols of contemporary dentistry. The purpose of this systematic review was to evaluate the effect of IDS on the bond strength of resin-based CAD/CAM materials to dentin. PubMed and MEDLINE, Scopus, and the Web of Science were searched by two individual researchers, namely for studies that have been published in English between 1 January 2005 and 31 December 2023 in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The inclusion criteria encompassed articles related to in vitro studies, measuring the bond strength through microtensile bond strength (μ-TBS), micro-shear bond strength (μ-SBS), tensile bond strength (TBS) or shear bond strength (SBS) tests after the use of the IDS technique. The included restorative materials comprised resin-based CAD/CAM materials bonded to dentin. A total of 1821 studies were identified, of which 7 met the inclusion criteria. A meta-analysis was not deemed appropriate due to the high level of diversity inthe publications and techniques. The use of IDS yielded higher bond strength outcomesin various experimental conditions and resin-based CAD/CAM materials. Overall, IDS in CAD/CAM restorations may contribute to better clinical outcomesand improved restoration longevity due to this property.
Collapse
Affiliation(s)
- Iliana Antoniou
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (I.A.); (P.M.); (K.T.)
| | - Petros Mourouzis
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (I.A.); (P.M.); (K.T.)
| | - Dimitrios Dionysopoulos
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (I.A.); (P.M.); (K.T.)
| | - Panagiotis Pandoleon
- Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
| | - Kosmas Tolidis
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (I.A.); (P.M.); (K.T.)
| |
Collapse
|
4
|
Hagino R, Mine A, Aoki-Matsumoto M, Miura J, Yumitate M, Ban S, Ishida M, Takaishi M, Van Meerbeek B, Yatani H, Ishigaki S. Effect of filler contents on the bond strength of CAD/CAM resin crowns: New resin primer versus conventional silane agents. J Prosthodont Res 2024; 68:283-289. [PMID: 37286502 DOI: 10.2186/jpr.jpr_d_22_00301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Purpose This study aims to evaluate the effects of resin primers containing methyl methacrylate (MMA) and silane agent on the bonding effectiveness of indirect resin composite blocks with three different filler contents.Methods A commercially available computer-aided design/computer-aided manufacturing (CAD/CAM) resin composite block and two experimental resin composite blocks with different filler contents were alumina-blasted and two surface treatments (primer and silane agent) were applied. The resin cement was built up, and the micro-tensile bond strength (μTBS) was measured after 24 hours, 1 month or 3 months of water storage (n = 24 per group). The fracture surfaces after μTBS measurements and resin block/cement interface were observed by scanning electron microscopy (SEM).Results The primer treatment group showed a significantly higher bond strength than the silane group only in F0 (filler content 0 wt%) group (P < 0.001). In the primer group, F0 and F41 (filler content 41 wt%) groups showed significantly higher bond strengths than F82 (filler content 82 wt%) group (P < 0.001). In contrast, in the silane group, F41 group showed significantly higher bond strength than F0 and F82 groups (P < 0.001), and F82 group showed significantly higher bond strength than F0 group (P < 0.001). SEM revealed that the matrix resin was partially destroyed on the fracture surface of the primer group, and an uneven interface surface was observed compared with that of the silane group.Conclusions MMA-containing primers showed higher bonding effectiveness to CAD/CAM resin composite blocks than the silane treatment.
Collapse
Affiliation(s)
- Ryosuke Hagino
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
| | - Atsushi Mine
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
| | - Mariko Aoki-Matsumoto
- Department of Restorative Dentistry, Hokkaido University Graduate School of Dental Medicine, Sapporo, Japan
- BIOMAT & University Hospitals Leuven, Department of Oral Health Sciences, KU Leuven (University of Leuven), Leuven, Belgium
| | - Jiro Miura
- Division for Interdisciplinary Dentistry, Osaka University Dental Hospital, Osaka, Japan
| | - Masahiro Yumitate
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
| | - Shintaro Ban
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
| | - Masaya Ishida
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
| | - Munechika Takaishi
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
| | - Bart Van Meerbeek
- BIOMAT & University Hospitals Leuven, Department of Oral Health Sciences, KU Leuven (University of Leuven), Leuven, Belgium
| | - Hirofumi Yatani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
| | - Shoichi Ishigaki
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
| |
Collapse
|
5
|
Turunç Oğuzman R, Şişmanoğlu S. Adhesive Performance of Resin Cement to Glass-Ceramic and Polymer-Based Ceramic CAD/CAM Materials after Applying Self-Etching Ceramic Primer or Different Surface Treatments. MATERIALS (BASEL, SWITZERLAND) 2023; 17:2. [PMID: 38203856 PMCID: PMC10780083 DOI: 10.3390/ma17010002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/13/2023] [Accepted: 12/15/2023] [Indexed: 01/12/2024]
Abstract
Ensuring optimum bond strength during cementation is vital for restoration success, with the practicality of the process being crucial in clinical practice. This study analyzed the effect of a single-step self-etching ceramic primer (MEP) and various surface treatments on the microshear bond strength (µSBS) between resin cement and glass-ceramic or polymer-based ceramic CAD/CAM materials. Specimens were fabricated from leucite-based glass-ceramic (LEU), lithium disilicate glass-ceramic (LDC), resin nanoceramic (RNC), and polymer infiltrated ceramic network (PICN) (n = 160). They were then classified based on the surface treatments (n = 10): control (no treatment); sandblasting with Al2O3 (AL); etching with hydrofluoric acid (HF); and MEP application. Scanning electron microscopy was used to evaluate the surface topography. µSBS was measured after cementation and thermocycling procedures. Failure modes were examined with a stereomicroscope. Statistical analysis involved two-way analysis of variance and Tukey HSD tests with a significance level of 0.05. µSBS was significantly influenced by both surface treatment and CAD/CAM material type. The most enhanced µSBS values for each material, regarding the surface treatment, were: LEU and LDC, HF; RNC, AL; PICN, AL or HF. MEP significantly increased the µSBS values of CAD/CAM materials except RNC, yet it did not yield the highest µSBS values for any of them.
Collapse
Affiliation(s)
- Rana Turunç Oğuzman
- Department of Prosthodontics, Faculty of Dentistry, Altınbaş University, 34147 Istanbul, Turkey
| | - Soner Şişmanoğlu
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul University-Cerrahpaşa, 34098 Istanbul, Turkey;
| |
Collapse
|
6
|
Porto TS, Medeiros da Silva IG, de Freitas Vallerini B, Fernando de Goes M. Different surface treatment strategies on etchable CAD-CAM materials: Part II-Effect on the bond strength. J Prosthet Dent 2023; 130:770-779. [PMID: 35101273 DOI: 10.1016/j.prosdent.2021.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 10/20/2021] [Accepted: 10/21/2021] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Bonding to recently launched polymer-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials has been challenging. Evidence regarding etching strategies for dual-phase CAD-CAM materials is sparse, but adequate bonding is crucial for the clinical success and longevity of a restoration. PURPOSE The purpose of this 2-part in vitro study was to evaluate and compare the effect of surface treatment strategies on the microshear bond strength and work of adhesion of polymer-based and ceramic materials. In addition, chemical elements present on the surface and the interface morphology after using those strategies were also assessed. MATERIALS AND METHODS Two CAD-CAM polymer and 1 CAD-CAM ceramic materials were selected for this in vitro study. The materials were subjected to different surface treatment strategies, including airborne-particle abrasion and the application of 9% hydrofluoric acid. Specimens were submitted to microshear bond strength before and after thermocycling, and the failure mode was classified. The work of adhesion was calculated based on the water-to-air surface tension of 72.8 mN.m-1 and the Young- Dupré equation. The surfaces were submitted to energy-dispersive X-ray spectroscopy, and the interfaces were analyzed using a scanning electron microscope. Data were subjected to 2-way ANOVA and the Tukey post hoc test (α=.05). RESULTS The highest microshear bond strength means were observed for the polymer-based materials when hydrofluoric acid or airborne-particle abrasion was applied. The 3 materials tested showed a decrease in microshear bond strength after thermocycling, except for applying airborne-particle abrasion to 1 of the polymer-based material tested. The ceramic material tested showed a high microshear bond strength with the application of airborne-particle abrasion and hydrofluoric acid combined. The work of adhesion varied across the materials and presented high means when hydrofluoric acid was used. CONCLUSIONS A combination of airborne-particle abrasion plus hydrofluoric acid should be considered for polymer-based or feldspathic ceramic CAD-CAM materials. In this in vitro study, both etching procedures combined produced higher bonding values for all materials tested.
Collapse
Affiliation(s)
- Thiago Soares Porto
- Assistant Professor, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio.
| | - Italo Guimaraes Medeiros da Silva
- Researcher, Department of Macromolecular Science and Engineering, School of Engineering, Case Western Reserve University, Cleveland, Ohio
| | - Bruna de Freitas Vallerini
- PhD Candidate, Department of Dental Materials and Prosthodontics, Araraquara School of Dentistry, Sao Paulo State University (UNESP), Sao Paulo, Brazil
| | - Mario Fernando de Goes
- Professor, Department of Restorative Dentistry (Dental Materials Area), Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo, Brazil
| |
Collapse
|
7
|
Didangelou P, Dionysopoulos D, Papadopoulos C, Strakas D, Mourouzis P, Tolidis K. Evaluation of repair bond strength of a dental CAD/CAM resin composite after surface treatment with two Er,Cr:YSGG laser protocols following artificial aging. J Mech Behav Biomed Mater 2023; 146:106101. [PMID: 37659166 DOI: 10.1016/j.jmbbm.2023.106101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 08/27/2023] [Accepted: 08/29/2023] [Indexed: 09/04/2023]
Abstract
The aim of the present study was to evaluate the impact of two Er,Cr:YSGG laser surface treatments on the repair bond strength of a dental CAD/CAM resin composite (Brilliant Crios) after artificial aging. Twenty-four resin-based CAD/CAM blocks were cut and 48 rectangular slabs (3 x 12 x 14 mm) were prepared. Preliminary SEM observations indicated the most favorable laser settings regarding surface modification of the tested restorative material. The CAD/CAM specimens were then divided into 4 groups (n=12) based on their surface pretreatment: no treatment, air abraded with 50-μm Al2O3 particles, and laser irradiated with two different protocols using Er,Cr:YSGG laser with average power 3.5 and 4.5 W, pulse repetition rate 35 and 50 Hz, and pulse energy 100 and 90 mJ, respectively. After surface treatments each group followed a bonding protocol with silane and a flowable resin composite was used to prepare 48 microrods. Half of the microrods of each group were subjected on shear bond strength (SBS) test (chisel-shaped blade, load cell of 500 N, crosshead speed of 1 mm/min) after 24 h, while the other half underwent artificial aging (15,000 cycles, 5-55 °C) and then SBS test. The debonded specimens were examined under an optical microscope to determine the failure mode. All specimens were also evaluated using SEM to assess the surface topography after the treatments. The results showed that SBS significantly decreased after thermocycling in all the experimental groups (p<0.05). Control group presented much lower SBS values than the other groups after both 24 h and thermocycling (p<0.05). The highest values of SBS exhibited air-abrasion group (p<0.05), followed by the two laser groups, which did not differ to each other (p>0.05). The results of the current study indicated that Er,Cr:YSGG laser irradiation can be an alternative treatment for repairing the tested resin-based CAD/CAM restorative material.
Collapse
Affiliation(s)
- Pavlina Didangelou
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Dimitrios Dionysopoulos
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece.
| | - Constantinos Papadopoulos
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Dimitrios Strakas
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Petros Mourouzis
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Kosmas Tolidis
- Department of Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
8
|
Asakura M, Aimu K, Hayashi T, Matsubara M, Mieki A, Ban S, Kawai T. Bonding Characteristics of Silane Coupling Agent and MMA-Containing Primer to Various Composite CAD/CAM Blocks. Polymers (Basel) 2023; 15:3396. [PMID: 37631453 PMCID: PMC10459957 DOI: 10.3390/polym15163396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 08/09/2023] [Accepted: 08/10/2023] [Indexed: 08/27/2023] Open
Abstract
This study evaluated the bonding characteristics of a silane coupling agent (SCA) and a methyl methacrylate (MMA)-containing primer (MCP) for 11 types of commercial composite blocks (CBs) for sandblasted and non-sandblasted surfaces. The shear bond strength (SBS) was measured according to ISO 29022: Notched-edge shear bond strength test. The SBS results demonstrated statistically significant differences between the CBs under all identical conditions. For the non-sandblasted groups, the SBSs of MCP-treated specimens were significantly higher than those of SCA-treated specimens for all but two CBs. Comparing the two treatments in sandblasted groups, the SBS was significantly higher for seven out of 11 MCP-treated RCB specimens, in contrast with three cases for the SCA-treated group. Two-way ANOVA for SBS showed the interaction effect between sandblasting and primer type for specific CBs, indicating that the sandblasting treatment improved SBS more effectively for SCA-treated specimens. Moreover, the effect of the SCA treatment was more material-dependent compared to that of the MCP treatment, which did not achieve a strong bond in all CBs but proved more effective than the SCA treatment, especially for non-sandblasted surfaces.
Collapse
Affiliation(s)
| | | | - Tatsuhide Hayashi
- Department of Dental Materials Science, School of Dentistry, Aichi Gakuin University, 1-00 Kusumoto-cho, Nagoya 464-8650, Japan; (M.A.); (K.A.); (M.M.); (A.M.); (S.B.); (T.K.)
| | | | | | | | | |
Collapse
|
9
|
Lankes V, Reymus M, Mayinger F, Coldea A, Liebermann A, Hoffmann M, Stawarczyk B. Three-Dimensional Printed Resin: Impact of Different Cleaning Protocols on Degree of Conversion and Tensile Bond Strength to a Composite Resin Using Various Adhesive Systems. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16093580. [PMID: 37176461 PMCID: PMC10179867 DOI: 10.3390/ma16093580] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/03/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023]
Abstract
The present investigation tested the effect of cleaning methods and adhesives on the tensile bond strength (TBS) of a resin-based composite luted to a temporary 3D printed resin. Substrates (n= 360) were printed using a Rapidshape D20II and cleaned with a butyldiglycol-based solution, isopropanol, or by centrifugation. Specimens were air-abraded with Al2O3 (mean particle size 50 µm) at 0.1 MPa followed by pretreatment (n = 30/subgroup) with: (1) Clearfil Ceramic Primer (CCP); (2) Clearfil Universal Bond (CUB); (3) Scotchbond Universal Plus (SUP) or 4. Visio.link (VL) and luted to PanaviaV5. TBS (n = 15/subgroup) was measured initially (24 h at 37 °C water) or after thermal cycling (10,000×, 5/55 °C). The degree of conversion (DC) for each cleaning method was determined prior and after air-abrasion. Univariate ANOVA followed by post-hoc Scheffé test was computed (p < 0.05). Using Ciba-Geigy tables and chi-square, failure types were analyzed. The DC values were >85% after all cleaning methods, with centrifugation showing the lowest. CCP pretreatment exhibited the lowest TBS values, with predominantly adhesive failures. The combination of CCP and centrifugation increased the TBS values (p < 0.001) compared to the chemical cleaning. CUB, SUP, and VL, regardless of cleaning, can increase the bond strength between the 3D printed resin and the conventional luting resin.
Collapse
Affiliation(s)
- Valerie Lankes
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Marcel Reymus
- Department of Conservative Dentistry and Peridontology, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Felicitas Mayinger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Andrea Coldea
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Anja Liebermann
- Head of the Department of Prosthetic Dentistry, Faculty of Medicine and University Hospital Cologne, 50931 Cologne, Germany
| | - Moritz Hoffmann
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Bogna Stawarczyk
- Scientific Head Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| |
Collapse
|
10
|
Calheiros-Lobo MJ, Vieira T, Carbas R, da Silva LFM, Pinho T. Effectiveness of Self-Adhesive Resin Luting Cement in CAD-CAM Blocks-A Systematic Review and Meta-Analysis. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2996. [PMID: 37109832 PMCID: PMC10140979 DOI: 10.3390/ma16082996] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/07/2023] [Accepted: 04/08/2023] [Indexed: 06/19/2023]
Abstract
Self-adhesive resin cements (SARCs) are used because of their mechanical properties, ease of cementation protocols, and lack of requirements for acid conditioning or adhesive systems. SARCs are generally dual-cured, photoactivated, and self-cured, with a slight increase in acidic pH, allowing self-adhesiveness and increasing resistance to hydrolysis. This systematic review assessed the adhesive strength of SARC systems luted to different substrates and computer-aided design and manufacturing (CAD/CAM) ceramic blocks. The PubMed/MedLine and Science Direct databases were searched using the Boolean formula [((dental or tooth) AND (self-adhesive) AND (luting or cement) AND CAD-CAM) NOT (endodontics or implants)]. Of the 199 articles obtained, 31 were selected for the quality assessment. Lava Ultimate (resin matrix filled with nanoceramic) and Vita Enamic (polymer-infiltrated ceramic) blocks were the most tested. Rely X Unicem 2 was the most tested resin cement, followed by Rely X Unicem > Ultimate > U200, and μTBS was the test most used. The meta-analysis confirmed the substrate-dependent adhesive strength of SARCs, with significant differences between them and between SARCs and conventional resin-based adhesive cement (α < 0.05). SARCs are promising. However, one must be aware of the differences in the adhesive strengths. An appropriate combination of materials must be considered to improve the durability and stability of restorations.
Collapse
Affiliation(s)
- Maria João Calheiros-Lobo
- UNIPRO—Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), Cooperativa de Ensino Superior Politécnico e Universitário (CESPU), Rua Central de Gandra 1317, 4585-116 Gandra, Portugal
- Conservative Dentistry, Department of Dental Sciences, University Institute of Health Sciences (IUCS), Cooperativa de Ensino Superior Politécnico e Universitário (CESPU), Rua Central de Gandra 1317, 4585-116 Gandra, Portugal
| | - Tatiana Vieira
- UNIPRO—Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), Cooperativa de Ensino Superior Politécnico e Universitário (CESPU), Rua Central de Gandra 1317, 4585-116 Gandra, Portugal
| | - Ricardo Carbas
- Department of Mechanical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
- INEGI—Institute of Science and Innovation in Mechanical and Industrial Engineering, University of Porto, 4200-465 Porto, Portugal
| | - Lucas F. M. da Silva
- Department of Mechanical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
- INEGI—Institute of Science and Innovation in Mechanical and Industrial Engineering, University of Porto, 4200-465 Porto, Portugal
| | - Teresa Pinho
- UNIPRO—Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), Cooperativa de Ensino Superior Politécnico e Universitário (CESPU), Rua Central de Gandra 1317, 4585-116 Gandra, Portugal
- IBMC—Instituto Biologia Molecular e Celular, i3S—Instituto de Inovação e Investigação em Saúde, Institute for Molecular and Cell Biology (IBMC), Institute of Innovation and Investigation in Health (i3S), University of Porto, 4200-135 Porto, Portugal
| |
Collapse
|
11
|
The Shear Bond Strength between Milled Denture Base Materials and Artificial Teeth: A Systematic Review. Dent J (Basel) 2023; 11:dj11030066. [PMID: 36975564 PMCID: PMC10046986 DOI: 10.3390/dj11030066] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 12/13/2022] [Accepted: 01/05/2023] [Indexed: 03/05/2023] Open
Abstract
The data about bond strength between digitally produced denture base resins and artificial teeth are scarce. Several studies investigated shear bond strength values of milled denture base resins and different types of artificial teeth. The purpose of the present study was to compare and evaluate the available evidence through a systematic review. A bibliographic search was conducted in PubMed, Scopus, and Web of Science to assess adequate studies published up to 1 June 2022. This review followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The appropriate studies that determined the shear bond strength values between milled denture base resins and artificial teeth were selected. The initial search identified 103 studies, which were included in the PRISMA 2020 flow diagram for new systematic reviews. Three studies met the inclusion criteria, and all of them present a moderate risk of bias (score 6). Two studies found no statistical differences between heat-polymerized and CAD/CAM (milled) denture base materials when attached with different types of artificial teeth, while one study showed higher values of CAD/CAM (milled) denture base materials. Bonding agents ensure bonding strength at least similar to the conventional methods. In order to improve the quality of future studies, it would be advantageous to use a larger number of specimens with standardized dimensions and a blinded testing machine operator to decrease the risk of bias.
Collapse
|
12
|
Zhu X, Shi J, Ye X, Ma X, Zheng M, Yang Y, Tan J. Influence of Cold Atmospheric Plasma on Surface Characteristics and Bond Strength of a Resin Nanoceramic. MATERIALS (BASEL, SWITZERLAND) 2022; 16:44. [PMID: 36614395 PMCID: PMC9821266 DOI: 10.3390/ma16010044] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/07/2022] [Accepted: 12/16/2022] [Indexed: 06/17/2023]
Abstract
The purpose of this study was to investigate the effect of cold atmospheric plasma (CAP) treatment on resin nanoceramic (RNC) surface state and its bond strength with resin cement. RNC with different surface treatments were prepared: control, sandblasting treatment (SB), hydrofluoric acid etching (HF) and plasma treatment of helium gas (CAP-He) and argon gas (CAP-Ar). The prepared samples were measured by SEM, Ra, Rz, contact angle goniometer, and XPS for surface characteristics. The shear bond test of RNC was examined in nine groups: SB + saline coupling agent (SL), HF + SL, CAP-He/Ar, CAP-He/Ar + SL, SB + CAP-He/Ar + SL, and control. The bond strength between RNC and resin cement was compared using shear bond strength test, before and after thermocycling. After CAP irradiation, the surface topography maintained, while the surface water contact angle was significantly reduced to 10.18° ± 1.36° (CAP-He) and 7.58° ± 1.79° (CAP-Ar). The removal of carbon contamination and inducing of oxygen radicals was detected after CAP treatment. The bond strength was improved by CAP treatment, but varied on CAP gas species and combination methods. CAP of Ar gas had better SBS than He gas. After thermocycling, CAP-Ar + SL showed the maximized shear bond strength (32.38 ± 1.42 MPa), even higher than SB + SL group (30.08 ± 2.80 MPa, p < 0.05). In conclusion, CAP treatment of helium and argon can improve the bonding properties of RNC by improving surface wettability, and CAP of argon gas combined with silane coupling agent shows the highest bond strength.
Collapse
Affiliation(s)
- Xiaoming Zhu
- Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing 100101, China
- National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
| | - Jiamin Shi
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, China
- Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou 510055, China
| | - Xinyi Ye
- National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, China
| | - Xinrong Ma
- Department of Stomotology, Peking University Third Hospital, Beijing 100191, China
| | - Miao Zheng
- Department of Stomotology, Peking University Third Hospital, Beijing 100191, China
| | - Yang Yang
- National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, China
| | - Jianguo Tan
- National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, China
| |
Collapse
|
13
|
Adhesion to a CAD/CAM Composite: Causal Factors for a Reliable Long-Term Bond. J Funct Biomater 2022; 13:jfb13040217. [PMID: 36412858 PMCID: PMC9680384 DOI: 10.3390/jfb13040217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 11/02/2022] [Accepted: 11/02/2022] [Indexed: 11/06/2022] Open
Abstract
Computer aided design/manufacturing (CAD/CAM) technology has become an increasingly popular part of dentistry, which today also includes CAD/CAM resin-based composite (RBC) applications. Because CAD/CAM RBCs are much more difficult to bond, many methods and attachment materials are still being proposed, while the best application method is still a matter of debate. The present study therefore evaluates causal factors for a reliable long-term bond, which includes the surface preparation of the CAD/CAM RBC, aging and the type of luting material. The reliability of the bond was calculated, and supplemented by fractography to identify fracture mechanisms. Five categories of luting materials were used: (1) temporary zinc phosphate cement, (2) glass ionomer cement (GIC), (3) resin-modified GIC, (4) conventional adhesive resin cement (ARC), and (5) self-adhesive RC. Half of the CAD/CAM RBC surfaces (n = 200) were sandblasted (SB) with 50 µm aluminum oxide, while the other half remained untreated. Bond strength measurements of the 400 resulting specimens were carried out after 24 h (n = 200) or after additional aging (10,000 thermo-cycles between 5 and 55 °C) (n = 200). The data were statistically analyzed using one- and three-way ANOVA followed by Games-Howell post-hoc test (α = 0.05) and Weibull analysis. Aging resulted in a significant decrease in bond strength primarily for the conventional cements. The highest bond strengths and reliabilities were recorded for both ARCs. SB caused a significant increase in bond strength for most luting materials, but also caused microcracks in the CAD/CAM RBC. These microcracks might compromise the long-term reliability of the bond in vivo.
Collapse
|
14
|
Graf T, Erdelt KJ, Güth JF, Edelhoff D, Schubert O, Schweiger J. Influence of Pre-Treatment and Artificial Aging on the Retention of 3D-Printed Permanent Composite Crowns. Biomedicines 2022; 10:biomedicines10092186. [PMID: 36140287 PMCID: PMC9496133 DOI: 10.3390/biomedicines10092186] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 08/28/2022] [Accepted: 08/29/2022] [Indexed: 11/16/2022] Open
Abstract
The aim of this in vitro study is to investigate the bonding properties of a 3D-printable permanent composite material in comparison to milled composite materials. The tested materials are 3D-printed BEGO VarseoSmile Crown plus (VA1_ab, VA1_nt, VA2_ab, VA2_nt), Vita Enamic (EN1, EN2), and 3M Lava Ultimate (UL1, UL2) (N = 64; n = 8). For this purpose, all crowns are luted to polymer tooth stumps #46 (FDI) using dual-curing luting composite, strictly according to the manufacturer’s instructions. VA1_ab and VA2_ab are additionally airborne-particle abraded. 4 groups (VA2_ab, VA2_nt, EN2, UL2) are artificially aged (1,200,000 cycles, 50 N, 10,000 thermocycles), whereby no specimen has failed. All 64 specimens undergo pull-off testing until retention loss. The mean forces of retention-loss is 786.6 ± 137.6 N (VA1_nt, *), 988.6 ± 212.1 N (VA2_nt, *, Ɨ), 1223.8 ± 119.2 N (VA1_ab, Ɨ, ǂ), 1051.9 ± 107.2 N (VA2_ab, *, Ɨ), 1185.9 ± 211.8 N (EN1, Ɨ, ǂ), 1485.0 ± 198.2 N EN2, ǂ), 1533.8 ± 42.4 N (UL1, ǂ), and 1521.8 ± 343.4 N (UL2, ǂ) (one-way ANOVA (Scheffé method); p < 0.05; *, Ɨ, ǂ: group distribution). No characteristic failure modes can be detected. In conclusion, all of the pull-off forces reflect retention values that seem to be sufficiently high for clinical use. Additional airborne-particle abrasion of VA does not result in significantly better retention but can be recommended.
Collapse
Affiliation(s)
- Tobias Graf
- Department of Prosthetic Dentistry, Center for Dentistry and Oral Health, Goethe University Frankfurt, 60596 Frankfurt am Main, Germany
- Correspondence: ; Tel.: +49-(0)69-6301-83617 or +49-06-963-014-787; Fax: +49-(0)69-6301-3711
| | - Kurt-Jürgen Erdelt
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Jan-Frederik Güth
- Department of Prosthetic Dentistry, Center for Dentistry and Oral Health, Goethe University Frankfurt, 60596 Frankfurt am Main, Germany
| | - Daniel Edelhoff
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Oliver Schubert
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Josef Schweiger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| |
Collapse
|
15
|
Inomata M, Harada A, Kasahara S, Kusama T, Ozaki A, Katsuda Y, Egusa H. Potential complications of CAD/CAM-produced resin composite crowns on molars: A retrospective cohort study over four years. PLoS One 2022; 17:e0266358. [PMID: 35390093 PMCID: PMC8989285 DOI: 10.1371/journal.pone.0266358] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 03/18/2022] [Indexed: 12/02/2022] Open
Abstract
Purpose Evaluation of the clinical performance of computer-aided design/computer-aided manufacturing-produced resin composite crowns (CAD/CAM composite crowns) on molars with a particular focus on placement location. Methods A retrospective cohort study was performed based on the clinical records of patients with CAD/CAM composite crowns on molars (June 2016 to March 2021). The hazard ratios (HRs) and 95% confidence intervals (95% CIs) were estimated based the Cox proportional hazard model to evaluate the effect of tooth location on complication type and occurrence. Covariates included crown location (maxilla/mandible, distalmost tooth/not distalmost tooth, and first molar/second or third molar) and endodontically treated (nonvital) or untreated (vital) tooth. Results Overall, 362 crowns were evaluated (mean follow-up: 378 days, median: 286 days), and 106 crowns (29.3%) showed complications, most frequently crown debonding. The cumulative success and survival rates were 70.9% and 93.7%, respectively, after 1 year and 49.5% and 86.5%, respectively, after 3 years. There was no significant difference in the HRs and log-rank tests in the Kaplan–Meier curves based on crown location parameters (P > 0.05). However, placement on vital teeth was associated with higher risks than on nonvital teeth (HR, 1.55; 95% CI, 1.03–2.23). In addition, the cement as a covariate yielded a high HR. Conclusions The location of CAD/CAM composite molar crowns is unlikely a risk factor for complications; therefore, these crowns can be clinically applied to all molars. However, the application of such molar crowns to vital teeth and the use of a cement other than adhesive resin cement present risks.
Collapse
Affiliation(s)
- Miyu Inomata
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Akio Harada
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
- * E-mail: (AH); (HE)
| | - Shin Kasahara
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Taro Kusama
- Division for Regional Community Development, Liaison Center for Innovative Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Akane Ozaki
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Yusuke Katsuda
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Hiroshi Egusa
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
- Division for Regional Community Development, Liaison Center for Innovative Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
- * E-mail: (AH); (HE)
| |
Collapse
|
16
|
Taira Y, Egoshi T, Kaida K. Effects of two methyl methacrylate-tributylborane-based luting agents with a silane-phosphate primer on bonding of four different CAD/CAM resin composite materials. J Oral Sci 2022; 64:167-171. [DOI: 10.2334/josnusd.21-0513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Yohsuke Taira
- Division of Cariology and Restorative Dentistry, Department of Prosthetic Dentistry, Graduate School of Biomedical Sciences, Nagasaki University
| | - Takafumi Egoshi
- Division of Cariology and Restorative Dentistry, Department of Prosthetic Dentistry, Graduate School of Biomedical Sciences, Nagasaki University
| | - Kei Kaida
- Division of Cariology and Restorative Dentistry, Department of Prosthetic Dentistry, Graduate School of Biomedical Sciences, Nagasaki University
| |
Collapse
|
17
|
Hagino R, Mine A, Matsumoto M, Yumitate M, Ban S, Yamanaka A, Ishida M, Miura J, Meerbeek BVAN, Yatani H. Combination of a silane coupling agent and resin primer reinforces bonding effectiveness to a CAD/CAM indirect resin composite block. Dent Mater J 2021; 40:1445-1452. [PMID: 34602585 DOI: 10.4012/dmj.2021-083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The effects of silanization and resin primer application on CAD/CAM indirect resin composite block bonding were investigated. KATANA AVENCIA P blocks (Kuraray Noritake Dental) were treated with a silane coupling agent and/or a resin primer. The contact angles (CAs) of resin primer were observed before and after silanization. Panavia V5 (Kuraray Noritake Dental) was built after each treatment. Bond strengths were measured, and the interface was analyzed by energy dispersive X-ray spectroscopy (EDS). The CA showed that silane treatment improved the wettability of the resin primer to the resin block. The combination treatment of the silane and resin primer showed significantly higher bond strength than no treatment, only in the silanization or resin primer group (p<0.001 each). EDS analysis showed that the resin primer penetrated both cement and block sides. The combination of the silane and resin primer improved bonding effectiveness between the resin block and resin cement.
Collapse
Affiliation(s)
- Ryosuke Hagino
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Atsushi Mine
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Mariko Matsumoto
- Department of Restorative Dentistry, Hokkaido University Graduate School of Dental Medicine.,KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry
| | - Masahiro Yumitate
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Shintaro Ban
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Azusa Yamanaka
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Masaya Ishida
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Jiro Miura
- Division for Interdisciplinary Dentistry, Osaka University Dental Hospital
| | - Bart VAN Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry
| | - Hirofumi Yatani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| |
Collapse
|
18
|
Effects of Immediate and Delayed Cementations for CAD/CAM Resin Block after Alumina Air Abrasion on Adhesion to Newly Developed Resin Cement. MATERIALS 2021; 14:ma14227058. [PMID: 34832458 PMCID: PMC8620113 DOI: 10.3390/ma14227058] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/17/2021] [Accepted: 11/18/2021] [Indexed: 11/24/2022]
Abstract
The purpose of this study was to evaluate the effect of one week of Computer-aided design/Computer-aided manufacturing (CAD/CAM) crown storage on the μTBS between resin cement and CAD/CAM resin composite blocks. The micro-tensile bond strength (μTBS) test groups were divided into 4 conditions. There are two types of CAD/CAM resin composite blocks, namely A block and P block (KATANA Avencia Block and KATANA Avencia P Block, Kuraray Noritake Dental, Tokyo, Japan) and two types of resin cements. Additionally, there are two curing methods (light cure and chemical cure) prior to the μTBS test—Immediate: cementation was performed immediately; Delay: cementation was conducted after one week of storage in air under laboratory conditions. The effect of Immediate and Delayed cementations were evaluated by a μTBS test, surface roughness measurements, light intensity measurements, water sorption measurements and Scanning electron microscope/Energy dispersive X-ray spectrometry (SEM/EDS) analysis. From the results of the μTBS test, we found that Delayed cementation showed significantly lower bond strength than that of Immediate cementation for both resin cements and both curing methods using A block. There was no significant difference between the two types of resin cements or two curing methods. Furthermore, water sorption of A block was significantly higher than that of P block. Within the limitations of this study, alumina air abrasion of CAD/CAM resin composite restorations should be performed immediately before bonding at the chairside to minimize the effect of humidity on bonding.
Collapse
|
19
|
Kabetani T, Ban S, Mine A, Ishihara T, Nakatani H, Yumitate M, Yamanaka A, Ishida M, Matsumoto M, Meerbeek BV, Shintani A, Yatani H. Four-year clinical evaluation of CAD/CAM indirect resin composite premolar crowns using 3D digital data: Discovering the causes of debonding. J Prosthodont Res 2021; 66:402-408. [PMID: 34565767 DOI: 10.2186/jpr.jpr_d_20_00287] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To analyze the causes of debonding of computer-aided design/computer-aided manufacturing (CAD/CAM) indirect resin composite premolar crowns with a focus on the morphological factors of the crown and abutment teeth. METHODS The clinical courses of 109 CAD/CAM indirect resin composite crowns were observed, and the patients' background characteristics, crown locations, luting methods, types of abutments, distal-most/non-distal-most molars, and types of resin blocks were confirmed. To investigate the influence of the morphology of the crown and abutment teeth, the 1) vertical dimension of the abutment teeth, 2) taper, and 3) thickness of the crown occlusal surface during events were measured from the three-dimensional digital data. The Kaplan-Meier method and multivariable Cox proportional hazard model were used for the statistical analyses. The nonlinearity of the effect of each comparison factor was included in the model. RESULTS Complications included 21 debonding cases, two crown fractures, five root fractures, and two core debondings. The cumulative no-debonding and no-crown-fracture rate over 1423 days (3 years and 11 months) was 77.4%. The multivariable Cox regression analysis revealed that the abutment teeth type of tooth (first or second premolar) (P = 0.02) and luting materials (P < 0.01) significantly influenced the debonding frequency. All morphological factors (1-3) significantly influenced the debonding. The hazard ratios and nonlinear graph indicated that the crown thickness was less effective than the vertical dimension and taper. CONCLUSIONS The combination analysis of clinical outcomes and 3D digital data revealed that preparation of the abutment is important for avoiding crown debonding.
Collapse
Affiliation(s)
- Tomoshige Kabetani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka
| | - Shintaro Ban
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka
| | - Atsushi Mine
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka
| | - Takuma Ishihara
- Department of Medical Statistics, Osaka City University Graduate School of Medicine and Faculty of Medicine, Osaka
| | - Hayaki Nakatani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka
| | - Masahiro Yumitate
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka
| | - Azusa Yamanaka
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka
| | - Masaya Ishida
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka
| | - Mariko Matsumoto
- Department of Restorative Dentistry, Hokkaido University Graduate School of Dental Medicine.,BIOMAT & University Hospitals Leuven, Department of Oral Health Sciences, KU Leuven (University of Leuven)
| | - Bart Vam Meerbeek
- Department of Restorative Dentistry, Hokkaido University Graduate School of Dental Medicine.,BIOMAT & University Hospitals Leuven, Department of Oral Health Sciences, KU Leuven (University of Leuven)
| | - Ayumi Shintani
- Department of Medical Statistics, Osaka City University Graduate School of Medicine and Faculty of Medicine, Osaka
| | - Hirofumi Yatani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka
| |
Collapse
|
20
|
Takahashi N, Kurokawa H, Wakamatsu K, Hirokane E, Takamizawa T, Miyazaki M, Kitahara N. Bonding ability of resin cements to different types of CAD/CAM composite blocks. Dent Mater J 2021; 41:134-141. [PMID: 34556595 DOI: 10.4012/dmj.2021-154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study investigated the bonding performance of two different types of resin cements to computer-aided design/computer-aided manufacturing (CAD/CAM) composite blocks based on the shear bond strength (SBS) test. A silane-containing self-adhesive resin cement (Panavia SA Cement Universal) and resin luting cement (Block HC Cem) with a primer, were used. Specimens were fabricated from three different types of CAD/CAM composite blocks, and their surfaces were blasted with alumina. Resin cements were bonded to the specimens, and their SBSs were measured after 15 min, 24 h, and after being subjected to thermal cycling for 10,000 and 30,000 cycles. Three-way ANOVA for bond strength revealed that CAD/CAM composite block, resin cement and storage time significantly influenced the SBS values, and the three-way interactions between the evaluated factors, and all the interactions were significant. It was concluded that the bonding performance of resin cements to CAD/CAM composite blocks were material and storage period dependent.
Collapse
Affiliation(s)
- Nao Takahashi
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Hiroyasu Kurokawa
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Kengo Wakamatsu
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Eizo Hirokane
- Department of Operative Dentistry, Nihon University School of Dentistry
| | | | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Nobuya Kitahara
- Department of Operative Dentistry, Nihon University School of Dentistry.,Team Tokyo Members Clinic
| |
Collapse
|
21
|
Mine A, Nikaido T, Matsumoto M, Takagaki T, Ishida M, Ban S, Yamanaka A, Takaishi M, Yumitate M, Hagino R, Van Meerbeek B, Yatani H. Status of decontamination methods after using dentin adhesion inhibitors on indirect restorations: An integrative review of 19 publications. JAPANESE DENTAL SCIENCE REVIEW 2021; 57:147-153. [PMID: 34522239 PMCID: PMC8424590 DOI: 10.1016/j.jdsr.2021.08.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 08/02/2021] [Accepted: 08/06/2021] [Indexed: 11/15/2022] Open
Abstract
The purpose of this review was to assess the literature regarding the decontamination of resin cement before the luting procedure in order to provide clinicians with a comparative overview of decontamination effects. A total of 19 articles were selected for inclusion in this review. The results indicated that bonding effectiveness is reduced due to residual adhesion inhibitors such as saliva, blood, hemostatic agents, and temporary/provisional cement. Self-etching and self-adhesive systems tend to be more negatively affected by adhesion inhibitors than do etch and rinse systems. Cleaning with an ultrasonic scaler or rotating brush have demonstrated conflicting effects in several studies. Some studies have reported that phosphoric acid has negative effects and recommend mild acid for decontamination. The application of phosphoric acid followed by sodium hypochlorite has been shown to help avoid negative effects. Alumina blasting has been investigated as a mechanical cleaning method in a relatively large number of experiments, most of which have confirmed its effectiveness. An intraoral cleaner containing functional monomers that has become commercially available in recent years is a promising method in clinical practice because it can easily and effectively remove temporary adhesive material. In addition, adhesion inhibitors can be easily removed from resin-coated dentin surfaces.
Collapse
Affiliation(s)
- Atsushi Mine
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka 565-0871, Japan
| | - Toru Nikaido
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University, Gifu 501-0296, Japan
| | - Mariko Matsumoto
- BIOMAT & University Hospitals Leuven, Department of Oral Health Sciences, KU Leuven (University of Leuven), Leuven 3000, Belgium.,Department of Restorative Dentistry, Hokkaido University Graduate School of Dental Medicine, Hokkaido 060-8586, Japan
| | - Tomohiro Takagaki
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University, Gifu 501-0296, Japan
| | - Masaya Ishida
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka 565-0871, Japan
| | - Shintaro Ban
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka 565-0871, Japan
| | - Azusa Yamanaka
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka 565-0871, Japan
| | - Munechika Takaishi
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka 565-0871, Japan
| | - Masahiro Yumitate
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka 565-0871, Japan
| | - Ryosuke Hagino
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka 565-0871, Japan
| | - Bart Van Meerbeek
- BIOMAT & University Hospitals Leuven, Department of Oral Health Sciences, KU Leuven (University of Leuven), Leuven 3000, Belgium
| | - Hirofumi Yatani
- A professor emeritus of Osaka University, Osaka 565-0871, Japan
| |
Collapse
|
22
|
In Vitro Investigations in a Biomimetic Approach to Restore One-Piece Zirconia Implants. MATERIALS 2021; 14:ma14164361. [PMID: 34442883 PMCID: PMC8400740 DOI: 10.3390/ma14164361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 07/27/2021] [Accepted: 07/31/2021] [Indexed: 11/21/2022]
Abstract
The objective of this study was to evaluate the fracture load and retention force of different bonding systems while restoring one-piece zirconia implants with a novel cementation approach using a mesostructure. Polymer-infiltrated ceramic mesostructures (n = 112) were therefore designed as caps on the implant abutment, and a molar feldspathic ceramic crown was constructed on top of it as a suprastructure. For cementation, different bonding systems were used. Fracture load and retention force were measured immediately after storage in water at 37 °C for 24 h (n = 8) as well as after artificial aging in a chewing simulator and subsequent thermal cycling (n = 8). Combined restorations showed higher fracture load compared to monolithic restorations of polymer-infiltrated ceramic (n = 8) or feldspathic ceramic (n = 8) identical in shape. However, the fracture load of the combined restorations was significantly affected by aging, independent of the primers and cements used. Restorations cemented with primers containing methyl methacrylate and 10-methacryloyloxydecyl dihydrogen phosphate exhibited the highest retention force values. Aging did not affect the retention force significantly. Similar fracture load values can be expected from combination restorations when compared with monolithic crowns.
Collapse
|
23
|
Chen Y, Chen D, Ding H, Chen Q, Meng X. Fatigue behavior of endodontically treated maxillary premolars with MOD defects under different minimally invasive restorations. Clin Oral Investig 2021; 26:197-206. [PMID: 34031731 DOI: 10.1007/s00784-021-03991-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Accepted: 05/14/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To analyze the stress distribution and subsequent fracture resistance of human maxillary premolars with mesial-occlusal-distal (MOD) defects restored with different minimally invasive restorations. MATERIALS AND METHODS Seventy non-carious human maxillary premolars were selected and divided into seven groups (n = 10). Ten teeth without further preparation served as control. The remaining teeth were endodontically treated and received three restorative patterns: inlays without cusp coverage (I), onlays with palatal coverage (O), overlays with both buccal and palatal coverage (Ov). Lithium disilicate glass ceramics (EM) and machinable composite resin (LU) were used for restoration. Specimens were tested under cycling loading with tongue direction of 45° for 1.2 × 106 cycles at a 50-N load and 2.0-Hz frequency. The survival time and two fracture mode classifications were assessed. Three-dimensional models of each group were designed. The magnitude and pattern of stresses were analyzed under the same condition of the in vitro test using finite element stress analysis. RESULTS Although the overlay model pattern produced more favorable stress distribution, three restorative patterns restored with the same material had no difference in survival curves (P > 0.05). Only the survival curve of the EM-Ov group had no statistical difference with that of the control group (P > 0.05). EM groups presented mainly interface adhesive failure, while LU groups were mainly material cohesive failure. CONCLUSION For the endodontically treated maxillary premolars with MOD defect, the lithium disilicate glass ceramic overlay pattern can reach the best restorative effect. CLINICAL RELEVANCE Comparing with restorative pattern, restorative material had a greater influence on the minimally invasive restoration of posterior teeth.
Collapse
Affiliation(s)
- Yani Chen
- Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, China
| | - Du Chen
- Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, China
| | - Hong Ding
- Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, China
| | - Qiang Chen
- Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing, Jiangsu, China
| | - Xiangfeng Meng
- Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, China.
| |
Collapse
|
24
|
Elter B, Aladağ A, Çömlekoğlu ME, Dündar Çömlekoğlu M, Kesercioğlu Aİ. Colour stability of sectional laminate veneers: A laboratory study. Aust Dent J 2021; 66:314-323. [PMID: 33721347 DOI: 10.1111/adj.12837] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 03/04/2021] [Accepted: 03/10/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND This study aimed to evaluate the colour stability of sectional laminate veneers (SLVs) fabricated with four and cemented with two different materials. METHODS Eighty SLVs were prepared with a thickness of 0.2-0.4 mm from IPS e.max CAD, Lava Ultimate, CEREC Blocs and IPS InLine and were cemented with Variolink Veneer and Variolink N to form eight groups (n:10). After cementation, specimens underwent 5000 thermocyles prior to immersion in a coffee solution. RESULTS Colour change before and after thermal cycling did not reveal significant differences (P > 0.05). After coffee immersion, significant colour change was observed in all groups (P > 0.05). Only IPS InLine cemented with Variolink Veneer was considered clinically acceptable (∆E < 3.3). According to observer scorings, marginal discolouration was higher in Lava Ultimate, while no discolouration was observed in IPS InLine. Dual or light-curing resin cements showed insignificant differences. CONCLUSIONS SLVs fabricated with different aesthetic materials underwent perceptible (∆E > 3.3) discolouration except for the IPS InLine cemented with light-curing resin cement. Cementation with either dual-curing or light-curing resin cements does not by itself affect colour stability. The highest marginal discolouration was in the Lava Ultimate group while no discolouration was detected in the IPS InLine group.
Collapse
Affiliation(s)
- B Elter
- Department of Prosthodontics, Faculty of Dentistry, Istanbul Okan University, Tuzla, Istanbul, Turkey
| | - A Aladağ
- Department of Prosthodontics, Faculty of Dentistry, Muğla Sıtkı Koçman University, Muğla, Turkey
| | - M E Çömlekoğlu
- Department of Prosthodontics, Faculty of Dentistry, Ege University, Bornova, Izmir, Turkey
| | - M Dündar Çömlekoğlu
- Department of Prosthodontics, Faculty of Dentistry, Ege University, Bornova, Izmir, Turkey
| | - A İ Kesercioğlu
- Department of Prosthodontics, Faculty of Dentistry, Ege University, Bornova, Izmir, Turkey
| |
Collapse
|
25
|
Review on Polymer, Ceramic and Composite Materials for CAD/CAM Indirect Restorations in Dentistry-Application, Mechanical Characteristics and Comparison. MATERIALS 2021; 14:ma14071592. [PMID: 33805176 PMCID: PMC8037100 DOI: 10.3390/ma14071592] [Citation(s) in RCA: 78] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 03/14/2021] [Accepted: 03/18/2021] [Indexed: 11/17/2022]
Abstract
The aim of this review article is to present various material groups, including ceramics, composites and hybrid materials, currently utilized in the field of CAD/CAM. The described technology is amongst the most important in modern prosthetics. Materials that are applicable in this technique are constantly tested, evaluated and improved. Nowadays, research on dental materials is carried out in order to meet the increasing demand on highly aesthetic and functional indirect restorations. Recent studies present the long-term clinical success of restorations made with the help of both ceramic and composite materials in the CAD/CAM method. However, new materials are developed and introduced that do not have long-term in vivo observations. We can outline a monolithic polymer-infiltrated ceramic network and zirconia teeth support that show promising results to date but require further assessment. The materials will be compared with regard to their mechanical and clinical properties, purpose, advantages and limitations.
Collapse
|
26
|
Abdou A, Takahashi R, Saad A, Nozaki K, Nikaido T, Tagami J. Influence of resin-coating on bond strength of resin cements to dentin and CAD/CAM resin block in single-visit and multiple-visit treatment. Dent Mater J 2021; 40:674-682. [PMID: 33518691 DOI: 10.4012/dmj.2020-160] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to evaluate the influence of resin-coating using one-bottle adhesives on the bond strength of resin cements in single-visit and multiple-visit treatments. Three one-bottle adhesives were used for resin-coating and/or pre-treatment adhesives prior to cementation, in conjunction with resin cements from the same manufacturers: Clearfil Universal Bond Quick with Panavia V5 (UBQ/Pv5), Scotchbond Universal Adhesive with RelyX Ultimate (SBU/RxU), and Optibond All-in-one with NX3 Nexus (OP/NX3). Bovine dentin surfaces were left uncoated or resin-coated. After 1-h water storage (single-visit) or 1-week water storage with a non-eugenol temporary cement (multiple-visit), a CAD/CAM resin block was cemented to uncoated or resin-coated dentin surfaces. Microtensile bond strengths (µTBSs) were measured and statistically analyzed (α=0.05). Application of resin-coating improved µTBSs. The multiple-visit group exhibited lower values of µTBS than the single-visit group. Selection of the materials affected µTBSs. Resin-coating and single-visit treatment are desirable for CAD/CAM resin composite restorations.
Collapse
Affiliation(s)
- Ahmed Abdou
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU).,Biomaterials Department, Faculty of Oral and Dental Medicine, Modern University for Technology and Information
| | - Rena Takahashi
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Amr Saad
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU).,Department of Operative Dentistry, Batterjee Medical College
| | - Kosuke Nozaki
- Department of Fixed Prosthodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Toru Nikaido
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU).,Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University
| | - Junji Tagami
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| |
Collapse
|
27
|
Prpić V, Schauperl Z, Glavina D, Ćatić A, Čimić S. Comparison of shear bond strengths of different types of denture teeth to different denture base resins. J Adv Prosthodont 2021; 12:376-382. [PMID: 33489022 PMCID: PMC7790604 DOI: 10.4047/jap.2020.12.6.376] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 11/12/2020] [Accepted: 12/09/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To determine the shear bond strengths of different denture base resins to different types of prefabricated teeth (acrylic, nanohybrid composite, and cross-linked) and denture teeth produced by computer-aided design/computer-aided manufacturing (CAD/CAM) technology. MATERIALS AND METHODS Prefabricated teeth and CAD/CAM (milled) denture teeth were divided into 10 groups and bonded to different denture base materials. Groups 1-3 comprised of different types of prefabricated teeth and cold-polymerized denture base resin; groups 4-6 comprised of different types of prefabricated teeth and heat-polymerized denture base resin; groups 7-9 comprised of different types of prefabricated teeth and CAD/CAM (milled) denture base resin; and group 10 comprised of milled denture teeth produced by CAD/CAM technology and CAD/CAM (milled) denture base resin. A universal testing machine was used to evaluate the shear bond strength for all specimens. One-way ANOVA and Tukey post-hoc test were used for analyzing the data (α=.05). RESULTS The shear bond strengths of different groups ranged from 3.37 ± 2.14 MPa to 18.10 ± 2.68 MPa. Statistical analysis showed significant differences among the tested groups (P<.0001). Among different polymerization methods, the lowest values were determined in cold-polymerized resin.There was no significant difference between the shear bond strength values of heat-polymerized and CAD/CAM (milled) denture base resins. CONCLUSION Different combinations of materials for removable denture base and denture teeth can affect their bond strength. Cold-polymerized resin should be avoided for attaching prefabricated teeth to a denture base. CAD/CAM (milled) and heat-polymerized denture base resins bonded to different types of prefabricated teeth show similar shear bond strength values.
Collapse
Affiliation(s)
- Vladimir Prpić
- School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| | - Zdravko Schauperl
- Department of Materials, Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia
| | - Domagoj Glavina
- Department of Pediatric and Preventive Dentistry, School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| | - Amir Ćatić
- Department of Prosthodontics, School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| | - Samir Čimić
- Department of Prosthodontics, School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| |
Collapse
|
28
|
Current status and perspective of CAD/CAM-produced resin composite crowns: a review of clinical effectiveness. JAPANESE DENTAL SCIENCE REVIEW 2020; 56:184-189. [PMID: 33299502 PMCID: PMC7704397 DOI: 10.1016/j.jdsr.2020.10.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 09/25/2020] [Accepted: 10/09/2020] [Indexed: 11/20/2022] Open
Abstract
The purpose of the present review was to survey the available literature on computer-aided design/computer-aided manufacturing (CAD/CAM)-produced resin composite materials to provide clinicians with a current overview of the key components necessary for daily clinical use. An electronic search was conducted in the PubMed database. Peer-reviewed articles in English language on the use of resin composites in CAD/CAM dental crowns were included. A total of 122 full-text articles were identified, 15 of which were selected during the initial review. Two additional articles were also discovered through a manual search, to obtain a final total of 17 articles included in the present review. Of these, 16 were to in vitro studies, and one was an in vivo study. Findings from the in vitro studies indicate that resin composite block materials for CAD/CAM applications demonstrate excellent physical properties and are appropriate for the clinical restoration of premolars and molars. However, the in vivo study reported a low 3-year success rate, but high survival rate for resin composite CAD/CAM crowns placed in the premolar region. The key to ensuring the successful prognosis of a resin composite CAD/CAM crown is to ensure that all steps—such as proper case selection, abutment tooth preparation, occlusal adjustment, and bonding—are accurately performed.
Collapse
|
29
|
Yano HT, Ikeda H, Nagamatsu Y, Masaki C, Hosokawa R, Shimizu H. Effects of alumina airborne-particle abrasion on the surface properties of CAD/CAM composites and bond strength to resin cement. Dent Mater J 2020; 40:431-438. [PMID: 33208574 DOI: 10.4012/dmj.2020-023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study is to clarify physical and chemical changes in surfaces of CAD/CAM composites caused by alumina airborne-particle abrasion and its effect on adhesive bonding. Our study involved three dispersed filler (DF)-based and a polymer-infiltrated ceramic network (PICN)-based CAD/CAM composites. Changes in the surface morphologies of the composites were examined, and surface free energy (SFE) analysis was performed based on Owens-Wendt theory. The influence of the abrasion on the bond strengths of CAD/CAM composites to the resin cement was characterized by shear bond strength (SBS) test. The abrasion increased the roughness of the composites. The SFE analysis showed that the abrasion significantly increased the dispersive component but decreased the polar component of the SFE associated with the DF-based composites, while no change occurred for those of the PICN-based composite. The abrasion slightly improved the SBSs for the DF-based composites but not that of the PICN-based composite.
Collapse
Affiliation(s)
- Haruka Takesue Yano
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University.,Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Chihiro Masaki
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University
| | - Ryuji Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University
| | - Hiroshi Shimizu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| |
Collapse
|
30
|
Abdou A, Takagaki T, Alghamdi A, Tichy A, Nikaido T, Tagami J. Bonding performance of dispersed filler resin composite CAD/CAM blocks with different surface treatment protocols. Dent Mater J 2020; 40:209-219. [PMID: 33162457 DOI: 10.4012/dmj.2020-049] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The effect of various pretreatments on the bonding of a resin cement to resin-composite CAD/CAM blocks (RCBs) was examined. The surface of dispersed-filler RCBs (DF-RCBs) and a polymer infiltrated ceramic network RCB (PICN-RCB) was roughened using hydrofluoric acid etching (HF) or sandblasting, and followed by silanization and/or universal adhesive (UA) application. Microtensile bond strength (µTBS), surface roughness parameters (arithmetical mean height (Sa); developed interfacial area ratio (Sdr)), and critical surface energy (γc) were determined. For most DF-RCBs, the highest µTBS was obtained using HF+UA. UA application to DF-RCBs resulted in similar or higher µTBS compared to silanization, which indicates that silane treatment is not crucial for DF-RCBs, especially after HF. In contrast, the highest µTBS to PICN-RCB was obtained with silanization. Both roughening pretreatments significantly increased the surface roughness parameters and the γc of all RCBs. The γc was positively correlated with Sa (r=0.756, p<0.001) and Sdr (r=0.837, p<0.001).
Collapse
Affiliation(s)
- Ahmed Abdou
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.,Biomaterials Department, Faculty of Oral and Dental Medicine, Modern University for Technology and Information
| | - Tomohiro Takagaki
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University
| | - Ali Alghamdi
- Al-Mikwah Dental Center, Saudi Ministry of Health
| | - Antonin Tichy
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University.,Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague
| | - Toru Nikaido
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University
| | - Junji Tagami
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| |
Collapse
|
31
|
Komine F, Honda J, Kusaba K, Kubochi K, Takata H, Fujisawa M. Clinical outcomes of single crown restorations fabricated with resin-based CAD/CAM materials. J Oral Sci 2020; 62:353-355. [PMID: 32741852 DOI: 10.2334/josnusd.20-0195] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Computer-aided design/computer-aided manufacturing (CAD/CAM) restorative materials have been widely used owing to a number of advantages, including stable quality of the materials, lower costs, and time-saving factors. Resin-based CAD/CAM materials for definitive restorations are classified into two groups: dispersed nanoparticle-filled composite resin and polymer-infiltrated-ceramic-network materials. Resin-based CAD/CAM materials have been applied to single crown restorations as a monolithic structure for the posterior region. In addition, resin-based CAD/CAM restorations have been applied recently for the anterior area. This literature review summarizes clinical outcomes, such as survival rates and clinical complications of single crown restorations fabricated with resin-based CAD/CAM materials.
Collapse
Affiliation(s)
- Futoshi Komine
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Junichi Honda
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Kosuke Kusaba
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Kei Kubochi
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Hiroki Takata
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Masanori Fujisawa
- Division of Fixed Prosthodontics, Department of Restorative & Biomaterials Sciences, Meikai University School of Dentistry
| |
Collapse
|
32
|
Hagino R, Mine A, Kawaguchi-Uemura A, Tajiri-Yamada Y, Yumitate M, Ban S, Miura J, Matsumoto M, Yatani H, Nakatani H. Adhesion procedures for CAD/CAM indirect resin composite block: A new resin primer versus a conventional silanizing agent. J Prosthodont Res 2020; 64:319-325. [PMID: 32423658 DOI: 10.1016/j.jpor.2019.09.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 09/09/2019] [Accepted: 09/12/2019] [Indexed: 11/24/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the effectiveness of both a resin primer containing methyl methacrylate (MMA) and a silanizing agent on bonding to indirect resin composite blocks, using two types of build-up hybrid resin composites. METHODS SHOFU BLOCK HC (Shofu) specimens were blasted with alumina, after which one of two surface treatments was applied: CERA RESIN BOND (Shofu, the Silane group) or HC primer (Shofu, the MMA group). Resin composites made using either Solidex Hardura (SDH, Shofu) or Ceramage Duo (CMD, Shofu) were built up and micro-tensile bond strength (μTBS) values were measured after storage in water for either 24h or 6 months (n=24 per group). The fracture surfaces after μTBS measurements and the resin block/build-up resin interfaces were observed by scanning electron microscopy (SEM). RESULTS The bond strength of the Silane/SDH group significantly decreased after 6 months (p<0.001), whereas in the MMA group there was no significant loss after 24h or 6 months (p=0.99). In the CMD group, the bond strength after 6 months was significantly lowered in both the Silane group (p<0.001) and the MMA group (p<0.001), but the latter still showed greater adhesion. SEM images demonstrated that the matrix resin was partially destroyed at the fracture surfaces of the MMA group and fracture surface unevenness was observed. CONCLUSIONS A primer containing MMA produced stronger bonding to CAD/CAM resin even after long-term aging compared to a silane treatment.
Collapse
Affiliation(s)
- Ryosuke Hagino
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan.
| | - Atsushi Mine
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan.
| | - Asuka Kawaguchi-Uemura
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Yuko Tajiri-Yamada
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Masahiro Yumitate
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Shintaro Ban
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Jiro Miura
- Division for Interdisciplinary Dentistry, Osaka University Dental Hospital, Japan
| | - Mariko Matsumoto
- Department of Restorative Dentistry, Hokkaido University Graduate School of Dental Medicine, Japan
| | - Hirofumi Yatani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| | - Hayaki Nakatani
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Japan
| |
Collapse
|
33
|
Yano HT, Ikeda H, Nagamatsu Y, Masaki C, Hosokawa R, Shimizu H. Correlation between microstructure of CAD/CAM composites and the silanization effect on adhesive bonding. J Mech Behav Biomed Mater 2020; 101:103441. [DOI: 10.1016/j.jmbbm.2019.103441] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 09/17/2019] [Accepted: 09/18/2019] [Indexed: 10/26/2022]
|
34
|
Ilie N, Ruse ND. Shear bond strength vs interfacial fracture toughness - Adherence to CAD/CAM blocks. Dent Mater 2019; 35:1769-1775. [PMID: 31690506 DOI: 10.1016/j.dental.2019.10.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Revised: 10/10/2019] [Accepted: 10/11/2019] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To compare shear bond strength (SBS) and interfacial fracture toughness (IKIC) results when assessing the effect of surface roughness and thermocycling on the adherence of a resin composite luting agent (RCLA) to a CAD/CAM resin composite block (RCB). METHODS Tetric CAD HT along with the recommended bonding system, Adhese Universal and Variolink Esthetic LC, were used. Surface roughness was achieved with 600/320/60 grit SiC papers. Samples were stored 24h in 37°C water or thermocycled 10000× (5°C-55°C) prior to testing. Results were analyzed by univariate ANOVA and Scheffé modified t-tests (α=0.05). Fractured specimens were viewed with a stereo microscope and selected specimens with a scanning electron microscope. RESULTS SBS results showed a significant difference between the 60 grit group and the other groups, both after 24h and thermocycling. A large number of SBS samples showed cohesive fracture or subsurface damage in RCB. Thermocycling led to a significant decrease in SBS in all groups. IKIC results showed no significant differences due to surface preparation after 24h storage in 37°C. After thermocycling, there was a significant difference between the 60 and the 600 grit groups. All KIC samples fractured adhesively at the RCB surface. KIC of the RCLA was significantly higher than IKIC of all groups. SIGNIFICANCE The results endorse the use of fracture mechanics methodology for the assessment and characterization of adherence, while identifying difficulties in its implementation. The results suggest also that adherence to CAD/CAM RCB may be limited by the strength of the resin composite block - adhesive interface.
Collapse
Affiliation(s)
- Nicoleta Ilie
- Department of Operative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-Universität, Goethestrasse 70, Munich, 80336, Germany.
| | - N Dorin Ruse
- Biomaterials, Faculty of Dentistry, UBC, 2199 Wesbrook Mall, Vancouver, BC, V6T 1Z3, Canada.
| |
Collapse
|