1
|
Wu D, Zhu J, Zheng Y, Fu L. Electrochemical Sensing Strategies for Synthetic Orange Dyes. Molecules 2024; 29:5026. [PMID: 39519667 PMCID: PMC11547196 DOI: 10.3390/molecules29215026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 10/16/2024] [Accepted: 10/22/2024] [Indexed: 11/16/2024] Open
Abstract
This review explores electrochemical sensing strategies for synthetic orange dyes, addressing the growing need for sensitive and selective detection methods in various industries. We examine the fundamental principles underlying the electrochemical detection of these compounds, focusing on their redox behavior and interaction with electrode surfaces. The review covers a range of sensor designs, from unmodified electrodes to advanced nanomaterial-based platforms. Chemically modified electrodes incorporating polymers and molecularly imprinted polymers are discussed for their enhanced selectivity. Particular attention is given to nanomaterial-based sensors, including those utilizing carbon nanotubes, graphene derivatives, and metal nanoparticles, which have demonstrated exceptional sensitivity and wide linear ranges. The potential of biological-based approaches, such as DNA interaction sensors and immunosensors, is also evaluated. Current challenges in the field are addressed, including matrix effects in complex samples and long-term stability issues. Emerging trends are highlighted, including the development of multi-modal sensing platforms and the integration of artificial intelligence for data analysis. The review concludes by discussing the commercial potential of these sensors in food safety, environmental monitoring, and smart packaging applications, emphasizing their importance in ensuring the safe use of synthetic orange dyes across industries.
Collapse
Affiliation(s)
- Dihua Wu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China;
| | - Jiangwei Zhu
- Co-Innovation Center for Sustainable Forestry in Southern China, Nanjing Forestry University, Nanjing 210037, China;
| | - Yuhong Zheng
- Institute of Botany, Jiangsu Province and Chinese Academy of Sciences, Nanjing Botanical Garden, Memorial Sun Yat-Sen, Nanjing 210014, China;
- Jiangsu Key Laboratory for the Research and Utilization of Plant Resources, Nanjing 210014, China
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China;
| |
Collapse
|
2
|
Yang M, Tan L, Batchelor-McAuley C, Compton RG. The solubility product controls the rate of calcite dissolution in pure water and seawater. Chem Sci 2024; 15:2464-2472. [PMID: 38362434 PMCID: PMC10866361 DOI: 10.1039/d3sc04063a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Accepted: 01/09/2024] [Indexed: 02/17/2024] Open
Abstract
Quantification of calcite dissolution underpins climate and oceanographic modelling. We report the factors controlling the rate at which individual crystals of calcite dissolved. Clear, generic criteria based on the change of calcite particle dimensions measured microscopically with time are established to indicate if dissolution occurs under kinetic or thermodynamic control. The dissolution of calcite crystals into water is unambiguously revealed to be under thermodynamic control such that the rate at which the crystal dissolved is controlled by the rate of diffusion of ions from a saturated surface layer adjacent to the calcite surface. As such the dissolution rate is controlled by the true stoichiometric solubility product which is inferred from the microscopic measurement as a function of the concentration of NaCl. Comparison with accepted literature values shows that the role of ion pairing at high ionic strengths as in seawater, specifically that of CaCO3 and other ion pairs, exerts a significant influence since these equilibria control the amount of dissolved calcium and carbonate ions in the later of solution immediately adjacent to the solid.
Collapse
Affiliation(s)
- Minjun Yang
- Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford South Parks Road Oxford UK
| | - Ling Tan
- Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford South Parks Road Oxford UK
| | | | - Richard G Compton
- Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford South Parks Road Oxford UK
| |
Collapse
|
3
|
Bolaños-Méndez D, Alvarez-Paguay J, Fernández L, Saavedra-Alulema PF, Veloz-Romero MS, Espinoza-Montero PJ. An inexpensive paracetamol sensor based on an acid-activated carbon fiber microelectrode. CHEMOSPHERE 2024; 346:140586. [PMID: 37939931 DOI: 10.1016/j.chemosphere.2023.140586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 10/20/2023] [Accepted: 10/27/2023] [Indexed: 11/10/2023]
Abstract
Paracetamol, a contaminant of emerging concern, has been detected in different bodies of water, where it can impact ecological and human health. To quantify this paracetamol, electroanalytical methods have gained support. Thus, the present study developed a simple, inexpensive, and environmentally friendly method for paracetamol quantification using a carbon fiber microelectrode based on commercial carbon fiber. To improve the carbon fiber microelectrode's paracetamol sensitivity and selectivity, it was subjected to an activation process via electrochemical oxidation in an acid medium (H2SO4 or HNO3), using 20 consecutive cycles of cyclic voltammetry. The treated (activated) carbon fiber microelectrode was characterized using scanning electron microscopy and electrochemical techniques, including chronoamperometry and electrochemical impedance spectroscopy. The H2SO4-activated carbon fiber microelectrode exhibited enhanced figures of merit, with a linear dynamic range of paracetamol detection from 0.5 to 11 μmol L-1 and a limit of detection of 0.21 μmol L-1 under optimized conditions. The method was optimized by quantifying paracetamol in commercial pharmaceutical tablets, spiked running tap water, and river water (Pita River, Quito, Ecuador, latitude -0.364955°, longitude -78.404538°); the respective recovery values were 102.89, 103.93, and 112.40%. The results demonstrated an acceptable level of accuracy and the promising applicability of this carbon fiber microelectrode as a sensor to detect paracetamol.
Collapse
Affiliation(s)
- Diego Bolaños-Méndez
- Pontificia Universidad Católica del Ecuador, Escuela de Ciencias Químicas, Quito, 170525, Ecuador
| | - Jocelyne Alvarez-Paguay
- Pontificia Universidad Católica del Ecuador, Escuela de Ciencias Químicas, Quito, 170525, Ecuador
| | - Lenys Fernández
- Pontificia Universidad Católica del Ecuador, Escuela de Ciencias Químicas, Quito, 170525, Ecuador.
| | | | - Moris S Veloz-Romero
- Universidad Central del Ecuador, Facultad de Ciencias Químicas, Quito, 170129, Ecuador
| | | |
Collapse
|
4
|
Vásquez-Velarde M, Fernández L, Bolaños-Méndez D, Burbano-Erazo H, Alvarez-Paguay J, Carrera P, Espinoza-Montero PJ. Evaluation of a gold-nanoparticle-modified carbon-fiber microelectrode to quantify mercury in canned tuna sold in Ecuador. CHEMOSPHERE 2023; 338:139483. [PMID: 37454989 DOI: 10.1016/j.chemosphere.2023.139483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 07/05/2023] [Accepted: 07/10/2023] [Indexed: 07/18/2023]
Abstract
Seafood consumption is the primary exposure route for trace metals like mercury. Accordingly, canned tuna meat has been focused on by researchers because of the potential bioaccumulation of high amounts of mercury. This study aimed to test a novel and reliable electroanalytical method employing a working electrode consisting of gold-nanoparticle-modified carbon microfibers to quantify total mercury in canned tuna samples. Determination was achieved via differential pulse anodic stripping voltammetry. The proposed method had a limit of detection of 3.9781 ± 0.0001 μg L-1 and a limit of quantification of 33.6634 ± 0.0001 μg L-1, with a sensitivity of 0.3275 nA μg L-1. The modified electrode was evaluated in samples taken from three canned tuna brands sold in the Sangolquí parish in Rumiñahui, Ecuador. These brands, coded A, B, and C, represent 47.92%, 27.08%, and 11.98% of all canned tuna sold in the Ecuadorian market, respectively. The resulting respective total mercury concentrations were 0.5999 ± 0.0001 mg kg-1; 0.9387 ± 0.0001 mg kg-1; and 0.3442 ± 0.0001 mg kg-1 for A, B, and C. Method accuracy was determined through the recovery percentages of ≥98%, which indicated acceptable accuracy for the final optimized method. Mean mercury concentrations for all samples did not represent a carcinogenic risk for consumers. However, the values obtained for potential no-carcinogenic risk and daily consumption rate suggest that consumers of tuna canned in water, particularly brand C, may be at risk.
Collapse
Affiliation(s)
- Milena Vásquez-Velarde
- Escuela de Ciencias Químicas, Pontificia Universidad Católica Del Ecuador, Quito 17 01 21-84, Ecuador
| | - Lenys Fernández
- Escuela de Ciencias Químicas, Pontificia Universidad Católica Del Ecuador, Quito 17 01 21-84, Ecuador.
| | - Diego Bolaños-Méndez
- Escuela de Ciencias Químicas, Pontificia Universidad Católica Del Ecuador, Quito 17 01 21-84, Ecuador
| | - Harold Burbano-Erazo
- Escuela de Ciencias Químicas, Pontificia Universidad Católica Del Ecuador, Quito 17 01 21-84, Ecuador
| | - Jocelyne Alvarez-Paguay
- Escuela de Ciencias Químicas, Pontificia Universidad Católica Del Ecuador, Quito 17 01 21-84, Ecuador
| | | | | |
Collapse
|
5
|
Shao Z, Chang Y, Venton BJ. Carbon microelectrodes with customized shapes for neurotransmitter detection: A review. Anal Chim Acta 2022; 1223:340165. [PMID: 35998998 PMCID: PMC9867599 DOI: 10.1016/j.aca.2022.340165] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 07/08/2022] [Accepted: 07/09/2022] [Indexed: 01/26/2023]
Abstract
Carbon is a popular electrode material for neurotransmitter detection due to its good electrochemical properties, high biocompatibility, and inert chemistry. Traditional carbon electrodes, such as carbon fibers, have smooth surfaces and fixed shapes. However, newer studies customize the shape and nanostructure the surface to enhance electrochemistry for different applications. In this review, we show how changing the structure of carbon electrodes with methods such as chemical vapor deposition (CVD), wet-etching, direct laser writing (DLW), and 3D printing leads to different electrochemical properties. The customized shapes include nanotips, complex 3D structures, porous structures, arrays, and flexible sensors with patterns. Nanostructuring enhances sensitivity and selectivity, depending on the carbon nanomaterial used. Carbon nanoparticle modifications enhance electron transfer kinetics and prevent fouling for neurochemicals that are easily polymerized. Porous electrodes trap analyte momentarily on the scale of an electrochemistry experiment, leading to thin layer electrochemical behavior that enhances secondary peaks from chemical reactions. Similar thin layer cell behavior is observed at cavity carbon nanopipette electrodes. Nanotip electrodes facilitate implantation closer to the synapse with reduced tissue damage. Carbon electrode arrays are used to measure from multiple neurotransmitter release sites simultaneously. Custom-shaped carbon electrodes are enabling new applications in neuroscience, such as distinguishing different catecholamines by secondary peaks, detection of vesicular release in single cells, and multi-region measurements in vivo.
Collapse
Affiliation(s)
- Zijun Shao
- Dept. of Chemistry, University of Virginia, Charlottesville, VA, 22904-4319, USA
| | - Yuanyu Chang
- Dept. of Chemistry, University of Virginia, Charlottesville, VA, 22904-4319, USA
| | - B Jill Venton
- Dept. of Chemistry, University of Virginia, Charlottesville, VA, 22904-4319, USA.
| |
Collapse
|
6
|
Janda DC, Barma K, Kurapati N, Klymenko OV, Oleinick A, Svir I, Amatore C, Amemiya S. Systematic Assessment of Adsorption-Coupled Electron Transfer toward Voltammetric Discrimination between Concerted and Non-Concerted Mechanisms. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
7
|
Abstract
Currently, hydrogen production is based on the reforming process, leading to the emission of pollutants; therefore, a substitute production method is imminently required. Water electrolysis is an ideal alternative for large-scale hydrogen production, as it does not produce any carbon-based pollutant byproducts. The production of green hydrogen from water electrolysis using intermittent sources (e.g., solar and eolic sources) would facilitate clean energy storage. However, the electrocatalysts currently required for water electrolysis are noble metals, making this potential option expensive and inaccessible for industrial applications. Therefore, there is a need to develop electrocatalysts based on earth-abundant and low-cost metals. Nickel-based electrocatalysts are a fitting alternative because they are economically accessible. Extensive research has focused on developing nickel-based electrocatalysts for hydrogen and oxygen evolution. Theoretical and experimental work have addressed the elucidation of these electrochemical processes and the role of heteroatoms, structure, and morphology. Even though some works tend to be contradictory, they have lit up the path for the development of efficient nickel-based electrocatalysts. For these reasons, a review of recent progress is presented herein.
Collapse
|
8
|
|
9
|
A simulation and experimental study of electrochemical pH control at gold interdigitated electrode arrays. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.139113] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
10
|
Coffman AJ, Lu J, Subotnik JE. A grid-free approach for simulating sweep and cyclic voltammetry. J Chem Phys 2021; 154:161101. [PMID: 33940857 DOI: 10.1063/5.0044156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
We present a computational approach to simulate linear sweep and cyclic voltammetry experiments that does not require a discretized grid in space to quantify diffusion. By using a Green's function solution coupled to a standard implicit ordinary differential equation solver, we are able to simulate current and redox species concentrations using only a small grid in time. As a result, where benchmarking is possible, we find that the current method is faster than (and quantitatively identical to) established techniques. The present algorithm should help open the door for studying adsorption effects in inner sphere electrochemistry.
Collapse
Affiliation(s)
- Alec J Coffman
- Department of Chemistry, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| | - Jianfeng Lu
- Departments of Mathematics, Physics, and Chemistry, Duke University, Durham, North Carolina 27708, USA
| | - Joseph E Subotnik
- Department of Chemistry, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| |
Collapse
|
11
|
Dourado AH, De Angelis LD, Arenz M, Córdoba de Torresi SI. L-cysteine oxidation on Pt and Au rotating disk electrodes: Insights on mixed controlled kinetics. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114920] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|