1
|
Motshakeri M, Angoro B, Phillips ARJ, Svirskis D, Kilmartin PA, Sharma M. Advancements in Mercury-Free Electrochemical Sensors for Iron Detection: A Decade of Progress in Electrode Materials and Modifications. SENSORS (BASEL, SWITZERLAND) 2025; 25:1474. [PMID: 40096308 PMCID: PMC11902859 DOI: 10.3390/s25051474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2025] [Revised: 02/18/2025] [Accepted: 02/24/2025] [Indexed: 03/19/2025]
Abstract
Efforts to quantify iron ion concentrations across fields such as environmental, chemical, health, and food sciences have intensified over the past decade, which drives advancements in analytical methods, particularly electrochemical sensors known for their simplicity, portability, and reliability. The development of electrochemical methods using non-mercury electrodes is increasing as alternatives to environmentally unsafe mercury-based electrodes. However, detecting iron species such as Fe(II) and Fe(III) remains challenging due to their distinct chemical properties, continuous oxidation-state interconversion, presence of interfering species, and complex behavior in diverse environments and matrixes. Selective trace detection demands careful optimization of electrochemical methods, including proper electrode materials selection, electrode surface modifications, operating conditions, and sample pretreatments. This review critically evaluates advancements over the past decade in mercury-free electrode materials and surface modification strategies for iron detection. Strategies include incorporating a variety of nanomaterials, composites, conducting polymers, membranes, and iron-selective ligands to improve sensitivity, selectivity, and performance. Despite advancements, achieving ultra-low detection limits in real-world samples with minimal interference remains challenging and emphasizes the need for enhanced sample pretreatment. This review identifies challenges, knowledge gaps, and future directions and paves the way for advanced iron electrochemical sensors for environmental monitoring, health diagnostics, and analytical precision.
Collapse
Affiliation(s)
- Mahsa Motshakeri
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand; (B.A.); (D.S.)
- School of Biological Sciences, Faculty of Science, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand;
| | - Barbara Angoro
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand; (B.A.); (D.S.)
| | - Anthony R. J. Phillips
- School of Biological Sciences, Faculty of Science, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand;
- Surgical and Translational Research Center, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand
| | - Darren Svirskis
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand; (B.A.); (D.S.)
| | - Paul A. Kilmartin
- School of Chemical Sciences, Faculty of Science, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand;
| | - Manisha Sharma
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand; (B.A.); (D.S.)
| |
Collapse
|
2
|
Esfandiari N, Aliofkhazraei M. Advances in the determination of trace amounts of iron cations through electrochemical methods: A comprehensive review of principles and their limits of detection. Talanta 2024; 277:126365. [PMID: 38964047 DOI: 10.1016/j.talanta.2024.126365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 05/31/2024] [Accepted: 06/04/2024] [Indexed: 07/06/2024]
Abstract
Quantification of trace amounts of iron is of great importance in various fields. In the industrial sector, it is crucial to monitor the release of iron out of corrosion, pickling treatment, and steel manufacturing to address potential environmental and economic challenges. In biological systems, despite its indispensability, it is essential to maintain iron concentration below a specific threshold. Electrochemical (EC) methods provide significant analytical capabilities due to their simplicity, ease of use, and cost-effectiveness. This review focuses on the fundamental principles of EC methods for iron detection, including potentiometry, amperometry, coulometry, voltammetry, and electrochemical impedance spectroscopy (EIS). It further explains the process of obtaining calibration curves, and subsequently, determining the concentration of unknown ions. Additionally, technical notes are presented on selecting the initial signal value, reducing the duration of tests, excluding non-faradaic signals, and extending the linear region with the lowest detection limit. These notes are supported by key findings from relevant case studies.
Collapse
Affiliation(s)
- Naeemeh Esfandiari
- Department of Materials Engineering, Faculty of Engineering, Tarbiat Modares University, P.O. Box: 14115-143, Tehran, Iran
| | - Mahmood Aliofkhazraei
- Department of Civil and Environmental Engineering, University of South Florida, Tampa, FL, 33620, USA.
| |
Collapse
|
3
|
Xhanari K, Finšgar M. Recent advances in the modification of electrodes for trace metal analysis: a review. Analyst 2023; 148:5805-5821. [PMID: 37697964 DOI: 10.1039/d3an01252b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/13/2023]
Abstract
This review paper summarizes the research published in the last five years on using different compounds and/or materials as modifiers for electrodes employed in trace heavy metal analysis. The main groups of modifiers are identified, and their single or combined application on the surface of the electrodes is discussed. Nanomaterials, film-forming substances, and polymers are among the most used compounds employed mainly in the modification of glassy carbon, screen-printed, and carbon paste electrodes. Composites composed of several compounds and/or materials have also found growing interest in the development of modified electrodes. Environmentally friendly substances and natural products (mainly biopolymers and plant extracts) have continued to be included in the modification of electrodes for trace heavy metal analysis. The main analytical performance parameters of the modified electrodes as well as possible interferences affecting the determination of the target analytes, are discussed. Finally, a critical evaluation of the main findings from these studies and an outlook discussing possible improvements in this area of research are presented.
Collapse
Affiliation(s)
- Klodian Xhanari
- University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia.
- University of Tirana, Faculty of Natural Sciences, Boulevard "Zogu I", 1001 Tirana, Albania
| | - Matjaž Finšgar
- University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia.
| |
Collapse
|
4
|
Sun Y, Xu G, Wang Y, Song P, Zhang Y, Xia L. Surface plasmon-assisted catalytic reduction of p-nitrothiophenol for the detection of Fe 2+ by surface-enhanced Raman spectroscopy. Anal Biochem 2023; 680:115314. [PMID: 37678582 DOI: 10.1016/j.ab.2023.115314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 08/12/2023] [Accepted: 09/04/2023] [Indexed: 09/09/2023]
Abstract
Herein, we developed a concise, time-efficient, and high selective assay for detecting Fe2+ through its triggered surface plasmon-assisted reduction reaction of p-nitrothiophenol (PNTP) to p,p'-dimercaptoazobenzene (DMAB) on the surface of gold nanoparticles (AuNPs) based on surface-enhanced Raman scattering (SERS) spectroscopy. When Fe2+ was added to the PNTP-AuNPs system, the appearance of three characteristic peaks at 1142, 1392, and 1440 cm-1 attributed to DMAB demonstrated that Fe2+ induced the catalytic coupling reaction of PNTP. The Raman intensity ratio of the peak at 1142 cm-1 to the peak at 1336 cm-1 and the concentration of Fe2+ presented a good linear response from 10 to 100 μM with a limit of detection (LOD) of 0.35 μM. More importantly, the entire detection process can be completed within 2 min and further successfully used for the detection of Fe2+ in river water.
Collapse
Affiliation(s)
- Ye Sun
- College of Chemistry, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Guangda Xu
- College of Chemistry, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Yue Wang
- College of Chemistry, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Peng Song
- College of Physics, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Yao Zhang
- College of Chemistry, Liaoning University, Shenyang, 110036, People's Republic of China; Chemistry and Chemical Engineering Guangdong Laboratory, Shantou, 515031, People's Republic of China.
| | - Lixin Xia
- College of Chemistry, Liaoning University, Shenyang, 110036, People's Republic of China.
| |
Collapse
|
5
|
Incorporating Quartz Crystal Microbalance with Chronoamperometry to Enhance Manganese Detection Stability in Drinking Water. Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.142156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
|
6
|
Thionine-mediated electrocatalytic reduction for electrochemical detection of EDTA-Fe(III) in soy sauce. Anal Bioanal Chem 2023; 415:639-648. [PMID: 36434171 DOI: 10.1007/s00216-022-04452-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 11/14/2022] [Accepted: 11/18/2022] [Indexed: 11/27/2022]
Abstract
Electrocatalytic reactions based on electron transfer mediators provide a simple and effective route for the development of convenient and sensitive electrochemical assays. Here, we report a novel electrocatalytic assay for detection of EDTA-Fe(III), which is widely used as a supplement in iron-fortified foods to reduce prevalence of iron deficiency. Unlike conventional electrochemical methods to detect Fe(III) ion, signaling mechanism of our electrocatalytic assay relies on the previously unexplored thionine-mediated electrochemical reduction of EDTA-Fe(III). This electrocatalytic detection method is sensitive for EDTA-Fe(III) detection in the linear concentration range from 10 to 750 μM with a detection limit of 2.5 μM. It is also specific enough and applicable to detection of EDTA-Fe(III) in real soy sauce samples with satisfactory recovery. The one-step electrocatalytic reduction for signal generation enables the direct and sensitive electrochemical detection of EDTA-Fe(III). We believe that this electrocatalytic assay can serve as a general platform for quantification of EDTA-Fe(III) in many EDTA-Fe(III)-fortified foods. And because thionine is increasingly used as a signal reporter in electrochemical DNA/aptamer sensors, the engineered electrocatalytic reaction of thionine-mediated electrochemical reduction of EDTA-Fe(III) will also provide a simple signal amplification means for the development of highly sensitive electrochemical biosensors.
Collapse
|
7
|
Kalhori S, Ahour F, Aurang P. Determination of trace amount of iron cations using electrochemical methods at N, S doped GQD modified electrode. Sci Rep 2023; 13:1557. [PMID: 36707641 PMCID: PMC9883219 DOI: 10.1038/s41598-023-28872-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 01/25/2023] [Indexed: 01/29/2023] Open
Abstract
In this work, nitrogen and sulfur co-doped graphene quantum dot-modified glassy carbon electrodes (N, S-GQD/GCE) were used for the recognition of iron cations in aqueous solutions. The dissolved cations are detected based on the faradaic reduction or oxidation current of Fe(III) and Fe(II) obtained at the N, S-GQD/GCE surface. Cyclic voltammetry (CV), square wave voltammetry (SWV), and hydrodynamic amperometry are used as suitable electrochemical techniques for studying electrochemical behavior and determination of Fe cations. Based on the obtained results, it is concluded that the presence of free electrons in the structure of N, S-GQD could facilitate electron transfer reaction between Fe(III) and electrode surface which with increased surface area results in increased sensitivity and lower limit of detection. By performing suitable experiments, the best condition for preparing the modified electrode and determining Fe(III) was selected. Under optimized conditions, the amperometric response is linear from 1 to 100 nM of Fe(III) with a detection limit of 0.23 nM. The validity of the method and applicability of the sensor is successfully tested by the determination of Fe(III) in drug and water real samples. This sensor opened a new platform based on doped nanoparticles for highly sensitive and selective detection of analytes.
Collapse
Affiliation(s)
- S. Kalhori
- grid.412763.50000 0004 0442 8645Department of Nanotechnology, Faculty of Chemistry, Urmia University, Urmia, Iran
| | - F. Ahour
- grid.412763.50000 0004 0442 8645Department of Nanotechnology, Faculty of Chemistry, Urmia University, Urmia, Iran ,grid.412763.50000 0004 0442 8645Institute of Nanotechnology, Urmia University, Urmia, Iran
| | - P. Aurang
- grid.412763.50000 0004 0442 8645Department of Nanotechnology, Faculty of Chemistry, Urmia University, Urmia, Iran
| |
Collapse
|
8
|
Hajipour M, Zamani HA, Karimi-Maleh H. Powerful and fast nanostructure electrochemical sensor for monitoring of carbidopa catechol-based drug in water and biological fluids. CHEMOSPHERE 2023; 312:137192. [PMID: 36368547 DOI: 10.1016/j.chemosphere.2022.137192] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 10/26/2022] [Accepted: 11/05/2022] [Indexed: 06/16/2023]
Abstract
Herein, to monitor the concentration of carbidopa in an aqueous solution, an analytical approach based on electrode surface modification by Pt/SWCNTs as a sensor has been proposed. Pt/SWCNTs was synthesized by polyol strategy and characterized by the TEM method. Results confirmed spherical Pt nanoparticles with a diameter of about 10 nm decorated at the surface of SWCNTs with good distribution. The carbon paste electrode modified (CPEM) with Pt/SWCNTs was fabricated by mixing 12% of nanocomposite as an optimum condition with graphite powder in the presence of paraffin oil as a binder. Carbidopa's oxidation signal was enhanced by about 2.73 times when using the CPEM/Pt/SWCNTs, and its oxidation potential was decreased by about 110 mV. Additionally, the sensor demonstrated a linear dynamic range of 1.0 nM-120 M with a detection limit of 0.5 nM at pH = 7.0 as the ideal condition for monitoring carbidopa. Therefore, carbidopa in water and dextrose saline can be detected using CPEM/Pt/SWCNTs with an acceptable recovery range.
Collapse
Affiliation(s)
- Masoumeh Hajipour
- Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran
| | - Hassan Ali Zamani
- Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran.
| | - Hassan Karimi-Maleh
- Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran; School of Resources and Environment, University of Electronic Science and Technology of China, 611731, Xiyuan Ave, Chengdu, PR China; Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran; Department of Sustainable Engineering, Saveetha School of Engineering, SIMATS, Chennai, 602105, India.
| |
Collapse
|
9
|
Construction of reversible enol-to-keto-to-enol tautomerization covalent organic polymer for sensitive, selective and multi-channel detection of iron (III). Anal Chim Acta 2022; 1232:340458. [DOI: 10.1016/j.aca.2022.340458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 09/27/2022] [Indexed: 11/17/2022]
|
10
|
Ponhong K, Siriangkhawut W, Lee CY, Teshima N, Grudpan K, Supharoek SA. Dual determination of nitrite and iron by a single greener sequential injection spectrophotometric system employing a simple single aqueous extract from Areca catechu Linn. serving as a natural reagent. RSC Adv 2022; 12:20110-20121. [PMID: 35919603 PMCID: PMC9272472 DOI: 10.1039/d2ra03870f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Accepted: 06/25/2022] [Indexed: 11/24/2022] Open
Abstract
Dual determination of nitrite and iron was proposed by using a single greener sequential injection (SI) spectrophotometric system employing a simple single aqueous extract from Areca catechu Linn. The extract served as a natural reagent to replace N-(1-naphthyl)ethylenediamine (NED) of the Griess reagent with nitrite and 1,10-phenanthroline with iron. The color products possessed analytical wavelengths at 430 and 560 nm, respectively. Conditions for the SI procedure were optimized using a univariate experimental design. Calibration ranges were up to 5.0 mg L-1 and 10.0 mg L-1 with limits of detection (LODs) of 0.04 mg L-1 and 0.05 mg L-1 for nitrite and iron(iii), respectively, and relative standard deviations (RSDs) being less than 3%. Recoveries of spiked standard nitrite and iron(iii) at 0.3 mg L-1 and 0.5 mg L-1 in water samples were 88 to 104% and 84 to 109%, respectively. The developed method successfully achieved dual determination of nitrite and total iron agreeing at a 95% confidence level with the reference methods of the conventional Griess assay and flame atomic absorption spectrometry (FAAS), respectively. The proposed method utilized locally available material from plants and serves the UN-SDGs.
Collapse
Affiliation(s)
- Kraingkrai Ponhong
- Multidisciplinary Research Unit of Pure and Applied Chemistry, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University Maha Sarakham 44150 Thailand
| | - Watsaka Siriangkhawut
- Multidisciplinary Research Unit of Pure and Applied Chemistry, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University Maha Sarakham 44150 Thailand
| | - Chang Young Lee
- School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology (UNIST) Ulsan 44919 Republic of Korea
| | - Norio Teshima
- Department of Applied Chemistry, Aichi Institute of Technology 1247 Yachigusa, Yakusa-cho Toyota 470-0392 Japan
| | - Kate Grudpan
- Department of Chemistry, Faculty of Science and Center of Excellence for Innovation in Analytical Science and Technology for Biodiversity-based Economic and Society, Chiang Mai University Chiang Mai 50200 Thailand
| | - Sam-Ang Supharoek
- Department of Medical Science, Mahidol University Amnatcharoen Campus Amnat Charoen 37000 Thailand
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University Bangkok 10400 Thailand
| |
Collapse
|
11
|
Screen-printed Gold Electrode Functionalized with Deferoxamine for Iron(III) Detection. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10060214] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Deferoxamine (DFO), a hydroxamic siderophore with a high affinity for Fe(III), is immobilized as a functionalized self-assembled monolayer of a thiol (SAM) on the gold surface of a screen-printed cell to develop a voltammetric sensor for iron(III). The surface of the working electrode was characterized, before and after functionalization, by determining surface properties such as the area and the double-layer capacitance. The Fe(III) detection was performed by DPV analysis after preconcentration of the cation at the open circuit potential in solution at pH = 1 for two minutes. The method was applied to the iron(III) quantification in water samples giving promising results.
Collapse
|
12
|
A new colorimetric chemosensor based on 1,3,4-oxadiazole derivative for the high selectivity and sensitivity of Fe3+ ion detection. J Mol Struct 2022. [DOI: 10.1016/j.molstruc.2021.132019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
13
|
Bongiovanni Abel S, Martinez MV, Bruno MM, Barbero CA, Abraham GA, Acevedo DF. A modular platform based on electrospun carbon nanofibers and poly(
N
‐isopropylacrylamide) hydrogel for sensor applications. POLYM ADVAN TECHNOL 2021. [DOI: 10.1002/pat.5473] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Silvestre Bongiovanni Abel
- Research Institute of Materials Science and Technology (INTEMA) National University of Mar del Plata (UNMdP)‐National Council of Scientific and Technical Research (CONICET) Mar del Plata Argentina
| | - María V. Martinez
- Research Institute for Energy Technologies and Advanced Materials (IITEMA) National University of Río Cuarto (UNRC)‐National Council of Scientific and Technical Research (CONICET) Río Cuarto Argentina
| | - Mariano M. Bruno
- Research Institute for Energy Technologies and Advanced Materials (IITEMA) National University of Río Cuarto (UNRC)‐National Council of Scientific and Technical Research (CONICET) Río Cuarto Argentina
| | - Cesar A. Barbero
- Research Institute for Energy Technologies and Advanced Materials (IITEMA) National University of Río Cuarto (UNRC)‐National Council of Scientific and Technical Research (CONICET) Río Cuarto Argentina
| | - Gustavo A. Abraham
- Research Institute of Materials Science and Technology (INTEMA) National University of Mar del Plata (UNMdP)‐National Council of Scientific and Technical Research (CONICET) Mar del Plata Argentina
| | - Diego F. Acevedo
- Research Institute for Energy Technologies and Advanced Materials (IITEMA) National University of Río Cuarto (UNRC)‐National Council of Scientific and Technical Research (CONICET) Río Cuarto Argentina
| |
Collapse
|
14
|
Nguyen LD, Doan TCD, Huynh TM, Dang DMT, Dang CM. Thermally reduced graphene/nafion modified platinum disk electrode for trace level electrochemical detection of iron. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106627] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
15
|
Phan LMT, Vo TAT, Hoang TX, Selvam SP, Pham HL, Kim JY, Cho S. Trending Technology of Glucose Monitoring during COVID-19 Pandemic: Challenges in Personalized Healthcare. ADVANCED MATERIALS TECHNOLOGIES 2021; 6:2100020. [PMID: 34179343 PMCID: PMC8212092 DOI: 10.1002/admt.202100020] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 02/18/2021] [Indexed: 05/11/2023]
Abstract
The COVID-19 pandemic has continued to spread rapidly, and patients with diabetes are at risk of experiencing rapid progression and poor prognosis for appropriate treatment. Continuous glucose monitoring (CGM), which includes accurately tracking fluctuations in glucose levels without raising the risk of coronavirus exposure, becomes an important strategy for the self-management of diabetes during this pandemic, efficiently contributing to the diabetes care and the fight against COVID-19. Despite being less accurate than direct blood glucose monitoring, wearable noninvasive systems can encourage patient adherence by guaranteeing reliable results through high correlation between blood glucose levels and glucose concentrations in various other biofluids. This review highlights the trending technologies of glucose sensors during the ongoing COVID-19 pandemic (2019-2020) that have been developed to make a significant contribution to effective management of diabetes and prevention of coronavirus spread, from off-body systems to wearable on-body CGM devices, including nanostructure and sensor performance in various biofluids. The advantages and disadvantages of various human biofluids for use in glucose sensors are also discussed. Furthermore, the challenges faced by wearable CGM sensors with respect to personalized healthcare during and after the pandemic are deliberated to emphasize the potential future directions of CGM devices for diabetes management.
Collapse
Affiliation(s)
- Le Minh Tu Phan
- Department of Electronic EngineeringGachon UniversitySeongnam‐siGyeonggi‐do13120Republic of Korea
- School of Medicine and PharmacyThe University of DanangDanang550000Vietnam
| | - Thuy Anh Thu Vo
- Department of Life ScienceGachon UniversitySeongnam‐siGyeonggi‐do461‐701Republic of Korea
| | - Thi Xoan Hoang
- Department of Life ScienceGachon UniversitySeongnam‐siGyeonggi‐do461‐701Republic of Korea
| | - Sathish Panneer Selvam
- Department of Electronic EngineeringGachon UniversitySeongnam‐siGyeonggi‐do13120Republic of Korea
| | - Hoang Lan Pham
- Department of Life ScienceGachon UniversitySeongnam‐siGyeonggi‐do461‐701Republic of Korea
| | - Jae Young Kim
- Department of Life ScienceGachon UniversitySeongnam‐siGyeonggi‐do461‐701Republic of Korea
| | - Sungbo Cho
- Department of Electronic EngineeringGachon UniversitySeongnam‐siGyeonggi‐do13120Republic of Korea
- Department of Health Sciences and TechnologyGAIHSTGachon UniversityIncheon21999Republic of Korea
| |
Collapse
|
16
|
Niu B, Yao B, Zhu M, Guo H, Ying S, Chen Z. Carbon paste electrode modified with fern leave-like MIL-47(as) for electrochemical simultaneous detection of Pb(II), Cu(II) and Hg(II). J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115121] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
17
|
Amiri M, Mahmoudi-Moghaddam H. Green synthesis of ZnO/ZnCo2O4 and its application for electrochemical determination of bisphenol A. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105663] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|