1
|
Critical Issues on the Surface Functionalization of Plasmonic Au-Ag/TiO 2 Thin Films with Thiolated Oligonucleotide-Based Biorecognition Elements. BIOSENSORS 2024; 14:159. [PMID: 38667152 PMCID: PMC11048063 DOI: 10.3390/bios14040159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 03/19/2024] [Accepted: 03/26/2024] [Indexed: 04/28/2024]
Abstract
This work reports on the surface functionalization of a nanomaterial supporting localized surface plasmon resonances (LSPRs) with (synthetic) thiolated oligonucleotide-based biorecognition elements, envisaging the development of selective LSPR-based DNA biosensors. The LSPR thin-film transducers are composed of noble metal nanoparticles (NPs) embedded in a TiO2 dielectric matrix, produced cost-effectively and sustainably by magnetron sputtering. The study focused on the immobilization kinetics of thiolated oligonucleotide probes as biorecognition elements, followed by the evaluation of hybridization events with the target probe. The interaction between the thiolated oligonucleotide probe and the transducer's surface was assessed by monitoring the LSPR signal with successive additions of probe solution through a microfluidic device. The device was specifically designed and fabricated for this work and adapted to a high-resolution LSPR spectroscopy system with portable characteristics. Benefiting from the synergetic characteristics of Ag and Au in the form of bimetallic nanoparticles, the Au-Ag/TiO2 thin film proved to be more sensitive to thiolated oligonucleotide binding events. Despite the successful surface functionalization with the biorecognition element, the detection of complementary oligonucleotides revealed electrostatic repulsion and steric hindrance, which hindered hybridization with the target oligonucleotide. This study points to an effect that is still poorly described in the literature and affects the design of LSPR biosensors based on nanoplasmonic thin films.
Collapse
|
2
|
Toward the autonomous flushing of building plumbing: Characterizing oxidation-reduction potential and temperature sensor dynamics. WATER RESEARCH 2024; 251:121098. [PMID: 38219686 DOI: 10.1016/j.watres.2023.121098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 12/05/2023] [Accepted: 12/30/2023] [Indexed: 01/16/2024]
Abstract
Manual flushing of building plumbing is commonly used to address water quality issues that arise from water stagnation. Autonomous flushing informed by sensors has the potential to aid in the management of building plumbing, but a number of knowledge gaps hinder its application. This study evaluates autonomous flushing of building plumbing with online sensor and actuator nodes deployed under kitchen sinks in five residential houses. Online oxidation-reduction potential (ORP) and temperature data were collected for nine weeks during the winter and summer in houses with both free chlorine and chloramine. ORP levels in houses with free chlorine residuals decreased after overnight stagnation. The overnight decrease in ORP was not observed when tap water was automatically flushed for five minutes at 6:00 h every morning. ORP levels in houses with chloramine residuals did not decrease consistently after overnight stagnation, and daily automated flushes did not have an observable effect on the ORP signals. Additional laboratory experiments were carried out to evaluate ORP signals during chlorine decay and after incremental changes in chlorine, as would be expected in building plumbing conditions. Results from the lab and field deployments suggest on-line ORP sensors may be used to detect free chlorine decay due to stagnating water, but are not as effective in detecting chloramine decay. However, field results also suggest ORP may not respond as expected on a timely manner after free chlorine or chloramine have been restored, hindering their applicability in developing control algorithms. In this paper we tested twice-daily five-minute automatic flushing and found that it counteracts water quality degradation associated with overnight stagnation in free chlorine systems. An automatic sensor-based flushing is proposed using online temperature sensor data to determine when flushing has reached water from the main. The results suggest that flushing informed by temperature sensors can reduce the flushing time by 46 % compared to the preset five-minute static flush.
Collapse
|
3
|
Stagnation arising through intermittent usage is associated with increased viable but non culturable Legionella and amoeba hosts in a hospital water system. Front Cell Infect Microbiol 2023; 13:1190631. [PMID: 37351181 PMCID: PMC10282743 DOI: 10.3389/fcimb.2023.1190631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 05/18/2023] [Indexed: 06/24/2023] Open
Abstract
Hospital water systems are a significant source of Legionella, resulting in the potentially fatal Legionnaires' disease. One of the biggest challenges for Legionella management within these systems is that under unfavorable conditions Legionella transforms itself into a viable but non culturable (VBNC) state that cannot be detected using the standard methods. This study used a novel method (flow cytometry-cell sorting and qPCR [VFC+qPCR] assay) concurrently with the standard detection methods to examine the effect of temporary water stagnation, on Legionella spp. and microbial communities present in a hospital water system. Water samples were also analyzed for amoebae using culture and Vermamoeba vermiformis and Acanthamoeba specific qPCR. The water temperature, number and duration of water flow events for the hand basins and showers sampled was measured using the Enware Smart Flow® monitoring system. qPCR analysis demonstrated that 21.8% samples were positive for Legionella spp., 21% for L. pneumophila, 40.9% for V. vermiformis and 4.2% for Acanthamoeba. All samples that were Legionella spp. positive using qPCR (22%) were also positive for VBNC Legionella spp.; however, only 2.5% of samples were positive for culturable Legionella spp. 18.1% of the samples were positive for free-living amoebae (FLA) using culture. All samples positive for Legionella spp. were also positive for FLA. Samples with a high heterotrophic plate count (HPC ≥ 5 × 103 CFU/L) were also significantly associated with high concentrations of Legionella spp. DNA, VBNC Legionella spp./L. pneumophila (p < 0.01) and V. vermiformis (p < 0.05). Temporary water stagnation arising through intermittent usage (< 2 hours of usage per month) significantly (p < 0.01) increased the amount of Legionella spp. DNA, VBNC Legionella spp./L. pneumophila, and V. vermiformis; however, it did not significantly impact the HPC load. In contrast to stagnation, no relationship was observed between the microbes and water temperature. In conclusion, Legionella spp. (DNA and VBNC) was associated with V. vermiformis, heterotrophic bacteria, and stagnation occurring through intermittent usage. This is the first study to monitor VBNC Legionella spp. within a hospital water system. The high percentage of false negative Legionella spp. results provided by the culture method supports the use of either qPCR or VFC+qPCR to monitor Legionella spp. contamination within hospital water systems.
Collapse
|
4
|
Challenges in the Hospital Water System and Innovations to Prevent Healthcare-Associated Infections. CURRENT TREATMENT OPTIONS IN INFECTIOUS DISEASES 2023. [DOI: 10.1007/s40506-023-00261-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
|
5
|
Tenets of a holistic approach to drinking water-associated pathogen research, management, and communication. WATER RESEARCH 2022; 211:117997. [PMID: 34999316 PMCID: PMC8821414 DOI: 10.1016/j.watres.2021.117997] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 12/13/2021] [Accepted: 12/19/2021] [Indexed: 05/10/2023]
Abstract
In recent years, drinking water-associated pathogens that can cause infections in immunocompromised or otherwise susceptible individuals (henceforth referred to as DWPI), sometimes referred to as opportunistic pathogens or opportunistic premise plumbing pathogens, have received considerable attention. DWPI research has largely been conducted by experts focusing on specific microorganisms or within silos of expertise. The resulting mitigation approaches optimized for a single microorganism may have unintended consequences and trade-offs for other DWPI or other interests (e.g., energy costs and conservation). For example, the ecological and epidemiological issues characteristic of Legionella pneumophila diverge from those relevant for Mycobacterium avium and other nontuberculous mycobacteria. Recent advances in understanding DWPI as part of a complex microbial ecosystem inhabiting drinking water systems continues to reveal additional challenges: namely, how can all microorganisms of concern be managed simultaneously? In order to protect public health, we must take a more holistic approach in all aspects of the field, including basic research, monitoring methods, risk-based mitigation techniques, and policy. A holistic approach will (i) target multiple microorganisms simultaneously, (ii) involve experts across several disciplines, and (iii) communicate results across disciplines and more broadly, proactively addressing source water-to-customer system management.
Collapse
|
6
|
Recovery of microbiological quality of long-term stagnant tap water in university buildings during the COVID-19 pandemic. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 806:150616. [PMID: 34592279 PMCID: PMC9752782 DOI: 10.1016/j.scitotenv.2021.150616] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 09/19/2021] [Accepted: 09/22/2021] [Indexed: 05/10/2023]
Abstract
Stagnant water can cause water quality deterioration and, in particular, microbiological contaminations, posing potential health risks to occupants. University buildings were unoccupied with little water usage during the COVID-19 pandemic. It's an opportunity to study microbiological quality of long-term stagnant water (LTSW) in university buildings. The tap water samples were collected for three months from four types of campus buildings to monitor water quality and microbial risks after long-term stagnation. Specifically, the residual chlorine, turbidity, and iron/zinc were disqualified, and the heterotrophic plate counts (HPC) exceeded the Chinese national standard above 100 times. It took 4-54 days for these parameters to recover to the routine levels. Six species of pathogens were detected with high frequency and levels (101-105 copies/100 mL). Remarkably, L. pneumophilia occurred in 91% of samples with turbidity > 1 NTU. The absence of the culturable cells for these bacteria possibly implied their occurrence in a viable but non-culturable (VBNC) status. The bacterial community of the stagnant tap water differed significantly and reached a steady state in more than 50 days. Furthermore, a high concentration of endotoxin (>10 EU/mL) was found in LTSW, which was in accordance with the high proportion of dead bacteria. The results suggested that the increased microbiological risks require more attention and the countermeasures before the building reopens should be taken.
Collapse
|
7
|
Legionella and Biofilms-Integrated Surveillance to Bridge Science and Real-Field Demands. Microorganisms 2021; 9:microorganisms9061212. [PMID: 34205095 PMCID: PMC8228026 DOI: 10.3390/microorganisms9061212] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/28/2021] [Accepted: 05/31/2021] [Indexed: 11/16/2022] Open
Abstract
Legionella is responsible for the life-threatening pneumonia commonly known as Legionnaires’ disease or legionellosis. Legionellosis is known to be preventable if proper measures are put into practice. Despite the efforts to improve preventive approaches, Legionella control remains one of the most challenging issues in the water treatment industry. Legionellosis incidence is on the rise and is expected to keep increasing as global challenges become a reality. This puts great emphasis on prevention, which must be grounded in strengthened Legionella management practices. Herein, an overview of field-based studies (the system as a test rig) is provided to unravel the common roots of research and the main contributions to Legionella’s understanding. The perpetuation of a water-focused monitoring approach and the importance of protozoa and biofilms will then be discussed as bottom-line questions for reliable Legionella real-field surveillance. Finally, an integrated monitoring model is proposed to study and control Legionella in water systems by combining discrete and continuous information about water and biofilm. Although the successful implementation of such a model requires a broader discussion across the scientific community and practitioners, this might be a starting point to build more consistent Legionella management strategies that can effectively mitigate legionellosis risks by reinforcing a pro-active Legionella prevention philosophy.
Collapse
|
8
|
Contamination of Water Sources of Karaj Hospitals with Legionella pneumophila and Campylobacter jejuni. INTERNATIONAL JOURNAL OF ENTERIC PATHOGENS 2020. [DOI: 10.34172/ijep.2020.29] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Background: One of the most common routes of infection development in humans is contaminated water. Legionella pneumophila and Campylobacter jejuni are the important causes of community- and hospital-acquired pneumonia and gastroenteritis that are transmitted to humans via the inhalation of contaminated water droplets and consumption of contaminated water, respectively. Thus, continuous monitoring of the water supply systems for these pathogens has great importance in public health. Objective: This study aimed to evaluate the water contamination of Karaj hospitals with these two bacterial species. Materials and Methods: In this study, 62 water samples were obtained from different parts of the hospitals of Karaj from April to September 2019, including air conditioning systems, dialysis equipment, ventilation tanks, and different wards of a hospital such as infectious diseases, pediatrics, gastroenterology, dialysis, and intensive and neonatal intensive care units. The samples were collected in sterile containers and immediately transferred to the laboratory for further analysis. The culture on specific media, staining, and biochemical tests were performed to identify the L. pneumophila and C. jejuni. Results: Out of 62 water samples, 25.8% (16 samples) were positive for L. pneumophila; 68.75% were observed in hot water samples, and 31.25% were attributed to cold water samples. Among 62 samples, 4.84% (3 samples) were positive for C. jejuni, which were all detected in hot water samples. Conclusion: Considering that the methods of water refinery of municipal water have no high efficiency, the quality improvement of the water sources of hospitals seems to be necessary.
Collapse
|
9
|
Evaluation of Legionella spp. Colonization in Residential Buildings Having Solar Thermal System for Hot Water Production. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17197050. [PMID: 32993154 PMCID: PMC7579049 DOI: 10.3390/ijerph17197050] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 09/23/2020] [Accepted: 09/24/2020] [Indexed: 11/17/2022]
Abstract
Despite an increase of literature data on Legionella spp. presence in private water systems, epidemiological reports assert a continuing high incidence of Legionnaires’ disease infection in Italy. In this study, we report a survey on Legionella spp. colonization in 58 buildings with solar thermal systems for hot water production (TB). In all buildings, Legionella spp. presence was enumerated in hot and cold water samples. Microbiological potability standards of cold water were also evaluated. Legionella spp. was detected in 40% of the buildings. Moreover, we detected correlations between the count of Legionella spp. and the presence of the optimal temperature for the microorganism growth (less than 40 °C). Our results showed that cold water was free from microbiological hazards, but Legionella spp., was detected when the mean cold water temperature was 19.1 ± 2.2 °C. This may considered close to the suboptimal value for the Legionella growth (more then 20 °C). In conclusion, we observed the presence of a Legionnaires’ disease risk and the need of some strategies aimed to reduce it, such as the application of training programs for all the workers involved in water systems maintenance.
Collapse
|
10
|
Considerations for large building water quality after extended stagnation. AWWA WATER SCIENCE 2020; 2:e1186. [PMID: 32838226 DOI: 10.31219/osf.io/qvj3b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 06/03/2020] [Accepted: 06/09/2020] [Indexed: 05/25/2023]
Abstract
The unprecedented number of building closures related to the coronavirus disease (COVID-19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer-reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.
Collapse
|
11
|
Considerations for Large Building Water Quality after Extended Stagnation. ACTA ACUST UNITED AC 2020; 2:e1186. [PMID: 32838226 PMCID: PMC7323006 DOI: 10.1002/aws2.1186] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 06/03/2020] [Accepted: 06/09/2020] [Indexed: 01/04/2023]
Abstract
The unprecedented number of building closures related to the coronavirus disease (COVID‐19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer‐reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.
Collapse
|
12
|
Evaluation of Legionella pneumophila Decrease in Hot Water Network of Four Hospital Buildings after Installation of Electron Time Flow Taps. WATER 2020. [DOI: 10.3390/w12010210] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Legionella spp. control is a critical issue in hospital with old water networks. Chemical disinfection methods are applied as a control measure over prolonged time periods, but Legionella may be resistant to chemical agents in pipeworks with low flow and frequent water stagnation. We evaluated Legionella spp. colonization in the hot water network of Italian hospitals after the installation of time flow taps (TFTs). In the period between 2017 and 2019, TFTs were installed in four hospital water networks. They were programmed in order to obtain a hot water flow of 192 L/day from each TFTs. A continuous chlorination system (chlorine dioxide) and a cold water pre-filtration device were applied in all the buildings. Before and after TFT installation, Legionella spp. was investigated at scheduled times. Before TFT installation, Legionella pneumophila was detected in all the hospitals with counts ranging from 2 × 102 to 1.4 × 105 CFU/L. After TFT installation, a loss in Legionella pneumophila culturability was always achieved in the period between 24 h and 15 days. Total chlorine concentration (Cl2) was detected in the range between 0.23 and 0.36 mg/L while temperature values were from 44.8 to 53.2 °C. TFTs together with chemical disinfection represent a method which improve water quality and disinfectant efficacy, reducing Legionella colonization in dead-end sections.
Collapse
|
13
|
Cost analysis for electron time-flow taps and point of use filters: a comparison of two methods for Legionnaires' disease prevention in hospital water networks. J Hosp Infect 2019; 103:231-232. [PMID: 31310790 DOI: 10.1016/j.jhin.2019.07.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 07/10/2019] [Indexed: 10/26/2022]
|
14
|
Environmental surveillance and spatio-temporal analysis of Legionella spp. in a region of northeastern Italy (2002-2017). PLoS One 2019; 14:e0218687. [PMID: 31287819 PMCID: PMC6615612 DOI: 10.1371/journal.pone.0218687] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Accepted: 06/06/2019] [Indexed: 01/01/2023] Open
Abstract
Legionella spp. are considered an important cause of potentially preventable morbidity and mortality, making environmental surveillance a crucial component of risk assessment plans. In this work, 20,319 water samples were collected in 3,983 environmental surveys during a 16-year period by ARPA, the Regional Agency for Environmental Protection, Friuli Venezia Giulia, and the results were studied to better understand the diffusion mechanisms of Legionella. The data showed a strong seasonal signal, a prevalence of L. pneumophila serogroup 2–15 in most environments (63% of positive samples), a prevalence of L. pneumophila serogroup 1 in swimming pool-associated environments (82% of positive samples), a persistent presence of Legionella in hospitals and a recurrent presence of Legionella in other facilities such as hotels, possibly years after interventions, highlighting the difficulty of eradicating the bacteria. Retrospective spatio-temporal analyses on geocoded historical data were carried out with SaTScan using an ordinal model with risk as a covariate to identify potential clusters with an excess of cases in the higher-risk categories. Although no outbreaks occurred during the period of study, such analyses identified spatially restricted zones with unusual contamination, which sometimes were also areas in which several surveys triggered by notifications of clinical cases were performed. Simulations of periodic prospective analyses permitted the assessment of the efficacy of the method in early detection of such clusters. The proposed method may be a useful tool in environmental surveillance, prevention and control of Legionella.
Collapse
|
15
|
A Proactive Environmental Approach for Preventing Legionellosis in Infants: Water Sampling and Antibiotic Resistance Monitoring, a 3-Years Survey Program. Healthcare (Basel) 2019; 7:healthcare7010039. [PMID: 30857147 PMCID: PMC6473578 DOI: 10.3390/healthcare7010039] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2019] [Revised: 03/02/2019] [Accepted: 03/06/2019] [Indexed: 11/16/2022] Open
Abstract
A proactive environmental monitoring program was conducted to determine the risk and prevent nosocomial waterborne infections of Legionella spp. in infants. Sink taps in a neonatal intensive care unit (NICU) and two obstetric clinics were monitored for Legionella spp. A total of 59 water samples were collected during a 3-year period and 20 of them were found colonized with Legionella pneumophila. Standard culture, molecular, and latex agglutination methods were used for the detection and identification of Legionella bacteria. Hospital personnel also proceeded with remedial actions (hyperchlorination and thermal shock treatment) in the event of colonization. The minimal inhibitory concentration (MIC) values of erythromycin, ciprofloxacin was determined for Legionella isolates using the e-test method. Our data indicate that the majority of neonatal sink-taps were colonized at least once during the study with Legionella spp. Among 20 isolates, 5 were considered as low-level resistant, 3 in erythromycin and 2 in ciprofloxacin, while no resistant strains were detected. Environmental surveillance in neonatal and obstetric units is suggested to prevent waterborne infections, and thus to reduce the risk of neonatal nosocomial infections.
Collapse
|
16
|
Role of hot water temperature and water system use on Legionella control in a tertiary hospital: An 8-year longitudinal study. WATER RESEARCH 2019; 149:460-466. [PMID: 30472548 DOI: 10.1016/j.watres.2018.11.032] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Revised: 10/24/2018] [Accepted: 11/14/2018] [Indexed: 06/09/2023]
Abstract
Although measures to minimize Legionella colonization in sanitary hot water installations are well established, there is little evidence of their long-term effectiveness in hospital buildings. During an 8-year period, hot water in a large hospital building was sampled monthly in areas with suitable dimensioning and recirculation and in areas with dead legs and low-use taps. In the former areas, the percentage of Legionella-negative samples was 83.2% when the temperature was ≥55%, 64.9% when between 50.1 °C and 54.0 °C, and 51.6% when ≤50 °C (p for trend <0.001). In the highest temperature group, no samples with ≥103 cfu/L were observed. In poorly designed areas, only 44.7% of samples were negative, and 28.9% presented ≥103 cfu/L although reaching 55 °C. In these areas, multivariate analysis showed that if hot water supplies were not used daily, the risk of Legionella colonization was greater than two-fold (odds ratio: 2.84; 95% confidence interval: 1.26-6.41), and the risk of finding Legionella concentrations ≥103 cfu/L was more than three-fold (odds ratio: 3.18; 95% confidence interval: 1.36-7.46), regardless the temperature. These findings indicate that the effectiveness of maintaining sanitary hot water at a minimum temperature of 55 °C is significantly better than that at 50 °C for the environmental control of Legionella but only in installations with suitable dimensioning and recirculation. In installations that do not meet these conditions, high temperatures alone result in insufficient control.
Collapse
|
17
|
Legionella Detection in Environmental Samples as an Example for Successful Implementation of qPCR. WATER 2018. [DOI: 10.3390/w10081012] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Waterborne diseases are a serious threat because of their ability to infect a high number of individuals in a short time span, such as during outbreaks of Legionellosis. This significantly highlights the need for the rapid detection and quantification of bacteria in environmental water samples. The aim of this study was to investigate the feasibility of quantitative Polymerase Chain Reaction (qPCR) for the detection of Legionellapneumophila (L. pneumophila) in environmental water samples and comparison of standard culture methods for Legionella detection with qPCR. Our study reached a negative predictive value (NPV) for L. pneumophila of 80.7% and for L. pneumophila serogroup 1 (sg1) the calculated NPV was 87.0%. The positive predictive value (PPV) for L. pneumophila was 53.9% and for L. pneumophila sg1 PPV was 21.4%. Results showed a correlation between qPCR and culture with an R2 value of 0.8973 for L. pneumophila, whereas no correlation was observed for the detection of L. pneumophila sg1. In our study, qPCR proved useful for the identification of L. pneumophila negative samples. However, despite the obvious benefits (sample handling, rapid generation of results), qPCR needs to be improved regarding the PPV before it can replace culture in water quality assessment.
Collapse
|