1
|
Ni JB, Ding CJ, Zhang JS, Fang XM, Xiao HW. Insight into the surface discharge cold plasma efficient inactivation of Pseudomonas fluorescens in water based on exogenous reactive oxygen and nitrogen species: Synergistic mechanism and energy benefits. JOURNAL OF HAZARDOUS MATERIALS 2024; 476:134984. [PMID: 38943891 DOI: 10.1016/j.jhazmat.2024.134984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 06/08/2024] [Accepted: 06/19/2024] [Indexed: 07/01/2024]
Abstract
As well known, surface discharge cold plasma has efficient inactivation ability and a variety of RONS are main active particles for inactivation, but their synergistic mechanism is still not clear. Therefore, surface discharge cold plasma system was applied to treat Pseudomonas fluorescens to study bacterial inactivation mechanism and energy benefit. Results showed that energy efficiency was directly proportional to applied voltage and inversely proportional to initial concentration. Cold plasma treatment for 20 min was inactivated by approximately > 4-log10Pseudomonas fluorescens and application of •OH and 1O2 scavengers significantly improved survival rate. In addition, •OH and 1O2 destroyed cell membrane structure and membrane permeability, which promoted diffusion of RONS into cells and affecting energy metabolism and antioxidant capacity, leading to bacterial inactivation. Furthermore, accumulation of intracellular NO and ONOOH was related to infiltration of exogenous RNS, while accumulation of •OH, H2O2, 1O2, O2- was the result of joint action of endogenous and exogenous ROS. Transcriptome analysis revealed that different RONS of cold plasma were responsible for Pseudomonas fluorescens inactivation and related to activation of intracellular antioxidant defense system and regulation of genes expression related to amino acid metabolism and energy metabolism, which promoting cellular process, catalytic activity and other biochemical pathways.
Collapse
Affiliation(s)
- Jia-Bao Ni
- College of Engineering, China Agricultural University, P.O. Box 194, 17 Qinghua Donglu, Beijing 100083, China; State Key Laboratory of Resource Insects, Institute of Apicultural Research, Chinese Academy of Agricultural Sciences, 1 Xiangshan Beigou, Beijing 100093, China
| | - Chang-Jiang Ding
- College of Science, Inner Mongolia University of Technology, Hohhot, China
| | - Jing-Shou Zhang
- College of Engineering, China Agricultural University, P.O. Box 194, 17 Qinghua Donglu, Beijing 100083, China
| | - Xiao-Ming Fang
- State Key Laboratory of Resource Insects, Institute of Apicultural Research, Chinese Academy of Agricultural Sciences, 1 Xiangshan Beigou, Beijing 100093, China.
| | - Hong-Wei Xiao
- College of Engineering, China Agricultural University, P.O. Box 194, 17 Qinghua Donglu, Beijing 100083, China.
| |
Collapse
|
2
|
Leili M, Afrasiabi S, Rostami R, Khazaei M, Roshani M, Tarin Z. The evaluation of Staphylococcus aureus and Staphylococcus epidermidis in hospital air, their antibiotic resistance and sensitivity of S. aureus to cefoxitin. Sci Rep 2024; 14:9183. [PMID: 38649676 PMCID: PMC11035647 DOI: 10.1038/s41598-024-59463-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Accepted: 04/10/2024] [Indexed: 04/25/2024] Open
Abstract
Staphylococci as a nosocomial infection agent, increases the possibility of contracting diseases such as wound infection, sepsis and skin infections in humans. It was shown that Staphylococcus aureus considered as a commensal organism causing various both endemic and epidemic hospital-acquired infections. Air samples were collected from Sina Hospital, Hamadan city, which dedicated to various respiratory diseases and analysed by biochemical tests. The resistance and sensitivity of bacterial strains to the cefoxitin antibiotic were also determined. Staphylococcus aureus density (CFU/m3) were measured in the air of various wards as follows: infectious 13.35 ± 7.57, poisoning 29.84 ± 33.43, emergency 8.64 ± 2.72, eye operation room 0, recovery room 6.28 ± 4.90, skin outpatient operation room 4.71 ± 2.36, respiratory isolation 0, ICU 0.79 ± 1.36, and the administrative room 6.28 ± 5.93; while the Staphylococcus epidermidis were as follows: infectious 1.57 ± 2.35, poisoning 2.35 ± 4.08, emergency 2.35 ± 2.35, eye operation room 0, recovery room 0.78 ± 1.36, skin outpatient operation room 2.35 ± 2.35, respiratory isolation 0, ICU 2.35 ± 4.08, and the administrative room 1.57 ± 1.36. The positive and negative control samples showed a concentration of 0. Moreover, among the S. aureus isolates, 33.3% were found to be resistant to cefoxitin, while 40.6% showed to be sensitive. Based on the results, the number of active people and the type and quality of ventilation are very effective in the air quality of various wards of hospital. The poisoning section showed the most contaminated air and the highest resistance and sensitivity to the cefoxitin antibiotic.
Collapse
Affiliation(s)
- Mostafa Leili
- Department of Environmental Health Engineering, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Sedighe Afrasiabi
- Department of Environmental Health Engineering, School of Public Health, Student Research Committee, Hamadan University of Medical Sciences, Hamadan, Iran.
| | - Roohollah Rostami
- Department of Environmental Health Engineering, Research Center for Health Sciences and Technologies, Semnan University of Medical Sciences, Semnan, Iran
| | - Mohammad Khazaei
- Department of Environmental Health Engineering, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Mahdaneh Roshani
- Department of Microbiology, Faculty of Medicine, Medical Microbiology, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Zahra Tarin
- Department of Occupational Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
3
|
Schleusener J, Lohan SB, Busch L, Zamudio Díaz DF, Opitz N, Sicher C, Lichtenthäler T, Danker K, Dommerich S, Filler T, Meinke MC, Zwicker P. Irradiation of human oral mucosa by 233 nm far UV-C LEDs for the safe inactivation of nosocomial pathogens. Sci Rep 2023; 13:22391. [PMID: 38104221 PMCID: PMC10725486 DOI: 10.1038/s41598-023-49745-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 12/11/2023] [Indexed: 12/19/2023] Open
Abstract
The inactivation of multi resistant pathogens is an important clinical need. One approach is UV-C irradiation, which was previously not possible in vivo due to cytotoxicity. Recently, far UV-C irradiation at λ < 240 nm was successfully used on skin with negligible damage. A potential application site is the nasal vestibule, where MRSA accumulates and cannot be treated using antiseptics. We irradiated 3D mucosa models and excised human mucosa with 222 and 233 nm far UV-C in comparison to 254 nm and broadband UV-B. Eradication efficiency was evaluated by counting colony forming units; irritation potential was evaluated by hen's egg-chorioallantoic membrane assay and trans epithelial electrical resistance; cell viability was assessed by MTT. DNA damage and cell protective mechanisms were evaluated immunohistopathologically. On mucosa models, MRSA reduced by ≈ 5 log10 for 60 mJ/cm2 irradiation at 233 nm. A slightly increased cell viability was observed after 24 h. Lower doses showed lower irritation potential than the positive controls or commercial mouthwash, while 80 mJ/cm2 had strong irritation potential. DNA damage occurred only superficially and decreased after 24 h. On excised human mucosa, < 10% of keratinocytes were affected after 150 mJ/cm2 222 nm or 60 mJ/cm2 233 nm.
Collapse
Affiliation(s)
- Johannes Schleusener
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117, Berlin, Germany.
| | - Silke B Lohan
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Loris Busch
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
- Department of Pharmaceutics and Biopharmaceutics, Philipps-Universität Marburg, Robert‑Koch‑Str. 4, 35032, Marburg, Germany
| | - Daniela F Zamudio Díaz
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
- Technische Universität Berlin, Institute of Food Technology and Food Chemistry, Gustav-Meyer-Allee 25, 13355, Berlin, Germany
| | - Nevin Opitz
- Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Ferdinand‑Sauerbruch‑Str., 17475, Greifswald, Germany
| | - Claudia Sicher
- Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Ferdinand‑Sauerbruch‑Str., 17475, Greifswald, Germany
| | - Tom Lichtenthäler
- Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Ferdinand‑Sauerbruch‑Str., 17475, Greifswald, Germany
| | - Kerstin Danker
- Institute of Biochemistry, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Steffen Dommerich
- Department of Otorhinolaryngology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Thomas Filler
- Ferdinand-Braun-Institut (FBH), Gustav‑Kirchhoff‑Str. 4, 12489, Berlin, Germany
| | - Martina C Meinke
- Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Paula Zwicker
- Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Ferdinand‑Sauerbruch‑Str., 17475, Greifswald, Germany
| |
Collapse
|
4
|
Pertegal V, Riquelme E, Lozano-Serra J, Cañizares P, Rodrigo MA, Sáez C, Lacasa E. Cleaning technologies integrated in duct flows for the inactivation of pathogenic microorganisms in indoor environments: A critical review of recent innovations and future challenges. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2023; 345:118798. [PMID: 37591101 DOI: 10.1016/j.jenvman.2023.118798] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 08/02/2023] [Accepted: 08/09/2023] [Indexed: 08/19/2023]
Abstract
Pathogenic microorganisms are a major concern in indoor environments, particularly in sensitive facilities such as hospitals, due to their potential to cause nosocomial infections. This study evaluates the concentration of airborne bacteria and fungi in the University Hospital Complex of Albacete (Spain), comparing the results with recent literature. Staphylococcus is identified as the most prevalent bacterial genus with a percentage distribution of 35%, while Aspergillus represents the dominant fungal genus at 34%. The lack of high Technology Readiness Levels (TRL 6, TRL 7) for effective indoor air purification requires research efforts to bridge this knowledge gap. A screening of disinfection technologies for pathogenic airborne microorganisms such as bacteria and fungi is conducted. The integration of filtration, irradiation or and (electro)chemical gas treatment systems in duct flows is discussed to enhance the design of the air-conditioning systems for indoor air purification. Concerns over microbial growth have led to recent studies on coating commercial fibrous air filters with antimicrobial particles (silver nanoparticles, iron oxide nanowires) and polymeric materials (polyaniline, polyvinylidene fluoride). Promising alternatives to traditional short-wave UV-C energy for disinfection include LED and Far-UVC irradiation systems. Additionally, research explores the use of TiO2 and TiO2 doped with metals (Ag, Cu, Pt) in filters with photocatalytic properties, enabling the utilization of visible or solar light. Hybrid photocatalysis, combining TiO2 with polymers, carbon nanomaterials, or MXene nanomaterials, enhances the photocatalytic process. Chemical treatment systems such as aerosolization of biocidal agents (benzalkonium chloride, hydrogen peroxide, chlorine dioxide or ozone) with their possible combination with other technologies such as adsorption, filtration or photocatalysis, are also tested for gas disinfection. However, the limited number of studies on the use of electrochemical technology poses a challenge for further investigation into gas-phase oxidant generation, without the formation of harmful by-products, to raise its TRL for effectively inactivating airborne microorganisms in indoor environments.
Collapse
Affiliation(s)
- Víctor Pertegal
- Department of Chemical Engineering, Higher Technical School of Industrial Engineering, University of Castilla-La Mancha, Edificio Infante Don Juan Manuel, Campus Universitario s/n, 02071, Albacete, Spain
| | - Eva Riquelme
- Clinical Parasitology and Microbiology Area. University Hospital Complex of Albacete, C/ Hermanos Falcó 37, 02006, Albacete, Spain
| | - Julia Lozano-Serra
- Clinical Parasitology and Microbiology Area. University Hospital Complex of Albacete, C/ Hermanos Falcó 37, 02006, Albacete, Spain
| | - Pablo Cañizares
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Manuel A Rodrigo
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Cristina Sáez
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Engracia Lacasa
- Department of Chemical Engineering, Higher Technical School of Industrial Engineering, University of Castilla-La Mancha, Edificio Infante Don Juan Manuel, Campus Universitario s/n, 02071, Albacete, Spain.
| |
Collapse
|
5
|
Guo L, Zhao P, Jia Y, Wang Z, Chen M, Zhang H, Liu D, Zhang Y, Wang X, Rong M. Inactivation of airborne pathogenic microorganisms by plasma-activated nebulized mist. JOURNAL OF HAZARDOUS MATERIALS 2023; 459:132072. [PMID: 37480605 DOI: 10.1016/j.jhazmat.2023.132072] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 06/21/2023] [Accepted: 07/14/2023] [Indexed: 07/24/2023]
Abstract
The airborne microorganisms in the aerosols are one main transmission way of pathogenic microorganisms and therefore inactivation of microorganisms in aerosols could effectively prevent the transmission of pathogenic microorganisms to control epidemics. The mist nebulized by plasma-activated air could effectively inactivate bacteria and could be developed for the sterilization of microorganisms in aerosols. In this study, the plasma-activated nebulized mist (PANM) was applied for the inactivation of microorganisms in aerosols and efficiently inactivated the bacteria, yeast, and viruses in aerosols after 2-min treatment. The PANM treatment caused morphologic changes and damage to the bacteria cells in aerosols. The PANM could also inactivate the microorganisms attached to the surface of the treatment chamber and the bacteria attached to the skin of mice within 6-min treatment. The biosafety assays demonstrated that the PANM treatment exhibited no effects on the behavior, hematological and serum biochemical parameters of blood, and organs from the mice. This study would supply an efficient, broad-spectrum, and safe aerosol sterilization strategy based on plasma technology to prevent the transmission of airborne microorganisms.
Collapse
Affiliation(s)
- Li Guo
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Pengyu Zhao
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Yikang Jia
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Zifeng Wang
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Min Chen
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Hao Zhang
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Dingxin Liu
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China.
| | - Yong Zhang
- State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Xiaohua Wang
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Mingzhe Rong
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| |
Collapse
|
6
|
Upadrasta A, Daniels S, Thompson TP, Gilmore B, Humphreys H. In situ generation of cold atmospheric plasma-activated mist and its biocidal activity against surrogate viruses for COVID-19. J Appl Microbiol 2023; 134:lxad181. [PMID: 37580171 DOI: 10.1093/jambio/lxad181] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 07/17/2023] [Accepted: 08/12/2023] [Indexed: 08/16/2023]
Abstract
AIMS To provide an alternative to ultra violet light and vapourized hydrogen peroxide to enhance decontamination of surfaces as part of the response to the COVID-19 pandemic. METHODS AND RESULTS We developed an indirect method for in situ delivery of cold plasma and evaluated the anti-viral activity of plasma-activated mist (PAM) using bacteriophages phi6, MS2, and phiX174, surrogates for SARS-CoV-2. Exposure to ambient air atmospheric pressure derived PAM caused a 1.71 log10 PFU ml-1 reduction in phi6 titer within 5 min and a 7.4 log10 PFU ml-1 reduction after 10 min when the the PAM source was at 5 and 10 cm. With MS2 and phiX174, a 3.1 and 1.26 log10 PFU ml-1 reduction was achieved, respectively, after 30 min. The rate of killing was increased with longer exposure times but decreased when the PAM source was further away. Trace amounts of reactive species, hydrogen peroxide and nitrite were produced in the PAM, and the anti-viral activity was probably attributable to these and their secondary reactive species. CONCLUSIONS PAM exhibits virucidal activity against surrogate viruses for COVID-19, which is time and distance from the plasma source dependent.
Collapse
Affiliation(s)
- Aditya Upadrasta
- Department of Clinical Microbiology, Royal College of Surgeons in Ireland, University of Medicine and Health Sciences, Dublin, D09 YD60, Ireland
| | - Stephen Daniels
- School of Electronic Engineering, Dublin City University, Dublin, D09 V209, Ireland
| | | | - Brendan Gilmore
- School of Pharmacy, Queen's University Belfast, Belfast BT9 7BL, Northern Ireland
| | - Hilary Humphreys
- Department of Clinical Microbiology, Royal College of Surgeons in Ireland, University of Medicine and Health Sciences, Dublin, D09 YD60, Ireland
| |
Collapse
|
7
|
Pereira AR, Braga DFO, Vassal M, Gomes IB, Simões M. Ultraviolet C irradiation: A promising approach for the disinfection of public spaces? THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 879:163007. [PMID: 36965719 DOI: 10.1016/j.scitotenv.2023.163007] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 03/10/2023] [Accepted: 03/18/2023] [Indexed: 05/17/2023]
Abstract
Ultraviolet irradiation C (UVC) has emerged as an effective strategy for microbial control in indoor public spaces. UVC is commonly applied for air, surface, and water disinfection. Unlike common 254 nm UVC, far-UVC at 222 nm is considered non-harmful to human health, being safe for occupied spaces, and still effective for disinfection purposes. Therefore, and allied to the urgency to mitigate the current pandemic of SARS-CoV-2, an increase in UVC-based technology devices appeared in the market with levels of pathogens reduction higher than 99.9 %. This environmentally friendly technology has the potential to overcome many of the limitations of traditional chemical-based disinfection approaches. The novel UVC-based devices were thought to be used in public indoor spaces such as hospitals, schools, and public transport to minimize the risk of pathogens contamination and propagation, saving costs by reducing manual cleaning and equipment maintenance provided by manpower. However, a lack of information about UVC-based parameters and protocols for disinfection, and controversies regarding health and environmental risks still exist. In this review, fundamentals on UVC disinfection are presented. Furthermore, a deep analysis of UVC-based technologies available in the market for the disinfection of public spaces is addressed, as well as their advantages and limitations. This comprehensive analysis provides valuable inputs and strategies for the development of effective, reliable, and safe UVC disinfection systems.
Collapse
Affiliation(s)
- Ana Rita Pereira
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Daniel F O Braga
- SpinnerDynamics, Lda., Rua da Junta de Freguesia 194, Escariz, 4540-322 Arouca, Portugal
| | - Mariana Vassal
- SpinnerDynamics, Lda., Rua da Junta de Freguesia 194, Escariz, 4540-322 Arouca, Portugal
| | - Inês B Gomes
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Manuel Simões
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
| |
Collapse
|
8
|
Alvarenga MOP, Dias JMM, Lima BJLA, Gomes ASL, Monteiro GQM. The implementation of portable air-cleaning technologies in healthcare settings - a scoping review. J Hosp Infect 2023; 132:93-103. [PMID: 36521582 PMCID: PMC9744491 DOI: 10.1016/j.jhin.2022.12.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 11/07/2022] [Accepted: 12/02/2022] [Indexed: 12/15/2022]
Abstract
The COVID-19 pandemic revealed opportunities to improve prevention practices in healthcare settings, mainly related to the spread of airborne microbes (also known as bioaerosols). This scoping review aimed to map methodologies used to assess the implementation of portable air cleaners in healthcare settings, identify gaps, and propose recommendations for future research. The protocol was registered in the Open Science Framework and reported following the checklist provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analysis - an extension for Scoping Reviews (PRISMA-ScR) statement. The search strategy was performed in five databases and one grey literature source. At the last selection phase, 24 articles that fulfilled our inclusion criteria were summarized and disseminated. Of these, 17 studies were conducted between 2020 and 2022; one of them was a protocol of a multicentre randomized controlled trial. The outcomes measured among the studies include airborne microbe counts, airborne particle concentrations, and rate of infections/interventions. The leading healthcare settings assessed were dental clinics (28%), patient's wards (16%), operating rooms (16%), and intensive care units (12%). Most of the devices demonstrated a significant potential to mitigate the impact of bioaerosols. Although some indoor air quality parameters can influence the mechanics of aerosols, only a few studies controlled these parameters in their analyses. Future clinical research should assess the rate of infections through randomized controlled trials with long-term follow-up and large sample sizes to determine the clinical importance of the findings.
Collapse
Affiliation(s)
- M O P Alvarenga
- Dental School, Universidade de Pernambuco, Pernambuco, Brazil
| | - J M M Dias
- Analytical Chemistry Laboratory, Instituto de Tecnologia de Pernambuco, Pernambuco, Brazil
| | - B J L A Lima
- Microbiology Testing Laboratory, Instituto de Tecnologia de Pernambuco, Pernambuco, Brazil
| | - A S L Gomes
- Department of Physics and Graduate Program in Dentistry, Universidade Federal de Pernambuco, Pernambuco, Brazil
| | - G Q M Monteiro
- Dental School, Universidade de Pernambuco, Pernambuco, Brazil.
| |
Collapse
|
9
|
Pérez-Gilaberte JB, Martín-Iranzo N, Aguilera J, Almenara-Blasco M, de Gálvez MV, Gilaberte Y. Correlation between UV Index, Temperature and Humidity with Respect to Incidence and Severity of COVID 19 in Spain. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:ijerph20031973. [PMID: 36767340 PMCID: PMC9915304 DOI: 10.3390/ijerph20031973] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/12/2023] [Accepted: 01/15/2023] [Indexed: 05/27/2023]
Abstract
BACKGROUND Various studies support the inverse correlation between solar exposure and Coronavirus SARS-CoV-2 infection. In Spain, from the Canary Islands to the northern part of the country, the global incidence of COVID-19 is different depending on latitude, which could be related to different meteorological conditions such as temperature, humidity, and ultraviolet index (UVI). The objective of the present work was to analyze the association between UVI, other relevant environmental factors such as temperature and humidity, and the incidence, severity, and mortality of COVID-19 at different latitudes in Spain. METHODS An observational prospective study was conducted, recording the numbers of new cases, hospitalizations, patients in critical units, mortality rates, and annual variations related to UVI, temperature, and humidity in five different provinces of Spain from January 2020 to February 2021. RESULTS Statistically significant inverse correlations (Spearman coefficients) were observed between UVI, temperature, annual changes, and the incidence of COVID-19 cases at almost all latitudes. CONCLUSION Higher ultraviolet radiation levels and mean temperatures could contribute to reducing COVID-19 incidence, hospitalizations, and mortality.
Collapse
Affiliation(s)
- Juan Blas Pérez-Gilaberte
- Department of Internal Medicine, Miguel Servet University Hospital, IIS Aragon, 50009 Zaragoza, Spain
| | | | - José Aguilera
- Photobiological Dermatology Laboratory Medical Research Center, Department of Dermatology and Medicine, School of Medicine, Campus Universitario de Teatinos S/N, 29071 Málaga, Spain
| | - Manuel Almenara-Blasco
- Department of Dermatology, Miguel Servet University Hospital, IIS Aragon, 50009 Zaragoza, Spain
| | - María Victoria de Gálvez
- Photobiological Dermatology Laboratory Medical Research Center, Department of Dermatology and Medicine, School of Medicine, Campus Universitario de Teatinos S/N, 29071 Málaga, Spain
| | - Yolanda Gilaberte
- Department of Dermatology, Miguel Servet University Hospital, IIS Aragon, 50009 Zaragoza, Spain
| |
Collapse
|
10
|
Dehghani S, SeyedAlinaghi S, Karimi A, Afroughi F, Abshenas S, Azad K, Tantuoyir MM, Mohammadi P, Ghavam SM, Mojdeganlou H, Dadras O, Nazarian N, Vahedi F, Barzegary A, Mehraeen E. Evaluating the effects of air disinfectants in decontamination of COVID-19 aerosols. Health Sci Rep 2023; 6:e1042. [PMID: 36644313 PMCID: PMC9831143 DOI: 10.1002/hsr2.1042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/20/2022] [Accepted: 12/22/2022] [Indexed: 01/12/2023] Open
Abstract
INTRODUCTION Airborne transmission is the most crucial mode of COVID-19 transmission. Therefore, disinfecting the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) aerosols float can have important implications in limiting COVID-19 transmission. Herein, we aimed to review the studies that utilized various disinfectants to decontaminate and inactivate the SARS-CoV-2 aerosols. METHODS This study was a review that studied related articles published between December 1, 2019 and August 23, 2022. We searched the online databases of PubMed, Scopus, Web of Science, Cochrane, on August 23, 2021. The studies were downloaded into the EndNote software, duplicates were removed, and then the studies were screened based on the inclusion/exclusion criteria. The screening process involved two steps; first, the studies were screened based on their title and abstract and then their full texts. The included studies were used for the qualitative analysis. RESULTS From 664 retrieved records, only 31 met the inclusion criteria and were included in the final qualitative analysis. Various materials like Ozone, H2O2, alcohol, and TiO2 and methods like heating and using Ultraviolet were described in these studies to disinfect places contaminated by COVID-19. It appeared that the efficacy of these disinfectants varies considerably depending on the situation, time, and ultimately their mode of application. CONCLUSION Following reliable protocols in combination with the proper selection of disinfectant agents for each purpose would serve to achieve desired elimination of the SARS-CoV-2 transmission.
Collapse
Affiliation(s)
- Soheil Dehghani
- School of medicineTehran University of Medical SciencesTehranIran
- Iranian Research Center for HIV/AIDS, Iranian Institute for Reduction of High Risk BehaviorsTehran University of Medical SciencesTehranIran
| | - SeyedAhmad SeyedAlinaghi
- Iranian Research Center for HIV/AIDS, Iranian Institute for Reduction of High Risk BehaviorsTehran University of Medical SciencesTehranIran
| | - Amirali Karimi
- School of medicineTehran University of Medical SciencesTehranIran
| | - Fatemeh Afroughi
- Pars HospitalIran University of Medical SciencesTehranIran
- School of medicineIslamic Azad UniversityTehranIran
| | - Shayan Abshenas
- School of medicineKashan University of Medical SciencesKashanIran
| | - Kimia Azad
- School of medicineIslamic Azad UniversityTehranIran
| | - Marcarious M. Tantuoyir
- School of medicineTehran University of Medical SciencesTehranIran
- Biomedical Engineering UnitUniversity of Ghana Medical Center (UGMC)AccraGhana
| | - Parsa Mohammadi
- School of medicineTehran University of Medical SciencesTehranIran
| | - Seyed Mohammad Ghavam
- Iranian Research Center for HIV/AIDS, Iranian Institute for Reduction of High Risk BehaviorsTehran University of Medical SciencesTehranIran
| | - Hengameh Mojdeganlou
- Department of PathologyThe Johns Hopkins University School of MedicineBaltimoreMarylandUSA
| | - Omid Dadras
- Iranian Research Center for HIV/AIDS, Iranian Institute for Reduction of High Risk BehaviorsTehran University of Medical SciencesTehranIran
- Department of Global Public Health and Primary CareUniversity of BergenBergenNorway
| | | | - Farzin Vahedi
- School of medicineTehran University of Medical SciencesTehranIran
| | | | - Esmaeil Mehraeen
- Department of Health Information TechnologyKhalkhal University of Medical SciencesKhalkhalIran
| |
Collapse
|
11
|
de Moraes Segundo JDDP, Constantino JSF, Calais GB, de Moura Junior CF, de Moraes MOS, da Fonseca JHL, Tsukamoto J, Monteiro RRDC, Andrade FK, d’Ávila MA, Arns CW, Beppu MM, Vieira RS. Virucidal PVP-Copper Salt Composites against Coronavirus Produced by Electrospinning and Electrospraying. Polymers (Basel) 2022; 14:polym14194157. [PMID: 36236105 PMCID: PMC9570984 DOI: 10.3390/polym14194157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 09/24/2022] [Accepted: 09/30/2022] [Indexed: 11/23/2022] Open
Abstract
Electrospinning technology was used to produced polyvinylpyrrolidone (PVP)-copper salt composites with structural differences, and their virucidal activity against coronavirus was investigated. The solutions were prepared with 20, 13.3, 10, and 6.6% w/v PVP containing 3, 1.0, 0.6, and 0.2% w/v Cu (II), respectively. The rheological properties and electrical conductivity contributing to the formation of the morphologies of the composite materials were observed by scanning electron microscopy (SEM). SEM images revealed the formation of electrospun PVP-copper salt ultrafine composite fibers (0.80 ± 0.35 µm) and electrosprayed PVP-copper salt composite microparticles (1.50 ± 0.70 µm). Energy-dispersive X-ray spectroscopy (EDS) evidenced the incorporation of copper into the produced composite materials. IR spectra confirmed the chemical composition and showed an interaction of Cu (II) ions with oxygen in the PVP resonant ring. Virucidal composite fibers inactivated 99.999% of coronavirus within 5 min of contact time, with moderate cytotoxicity to L929 cells, whereas the virucidal composite microparticles presented with a virucidal efficiency of 99.999% within 1440 min of exposure, with low cytotoxicity to L929 cells (mouse fibroblast). This produced virucidal composite materials have the potential to be applied in respirators, personal protective equipment, self-cleaning surfaces, and to fabric coat personal protective equipment against SARS-CoV-2, viral outbreaks, or pandemics.
Collapse
Affiliation(s)
- João de Deus Pereira de Moraes Segundo
- Department of Chemical Engineering, Federal University of Ceará, Fortaleza 60455-760, Brazil
- Department of Materials and Bioprocess Engineering, University of Campinas, Campinas 13083-852, Brazil
- Department of Manufacturing and Materials Engineering, University of Campinas, Campinas 13083-860, Brazil
- Correspondence: (J.d.D.P.d.M.S.); (R.S.V.)
| | | | - Guilherme Bedeschi Calais
- Department of Materials and Bioprocess Engineering, University of Campinas, Campinas 13083-852, Brazil
| | | | - Maria Oneide Silva de Moraes
- Thematic Laboratory of Microscopy and Nanotechnology, National Institute of Amazonian Research, Manaus 69067-001, Brazil
| | | | - Junko Tsukamoto
- Department of Genetics, Evolution, Microbiology and Immunology, University of Campinas, Campinas 13083-970, Brazil
| | | | - Fábia Karine Andrade
- Department of Chemical Engineering, Federal University of Ceará, Fortaleza 60455-760, Brazil
| | - Marcos Akira d’Ávila
- Department of Manufacturing and Materials Engineering, University of Campinas, Campinas 13083-860, Brazil
| | - Clarice Weis Arns
- Department of Genetics, Evolution, Microbiology and Immunology, University of Campinas, Campinas 13083-970, Brazil
| | - Marisa Masumi Beppu
- Department of Materials and Bioprocess Engineering, University of Campinas, Campinas 13083-852, Brazil
| | - Rodrigo Silveira Vieira
- Department of Chemical Engineering, Federal University of Ceará, Fortaleza 60455-760, Brazil
- Correspondence: (J.d.D.P.d.M.S.); (R.S.V.)
| |
Collapse
|
12
|
Fuchs FM, Bibinov N, Blanco EV, Pfaender S, Theiß S, Wolter H, Awakowicz P. Characterization of a robot-assisted UV-C disinfection for the inactivation of surface-associated microorganisms and viruses. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY 2022; 11:100123. [PMID: 36034107 PMCID: PMC9392416 DOI: 10.1016/j.jpap.2022.100123] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/07/2022] [Accepted: 04/30/2022] [Indexed: 11/26/2022] Open
Abstract
Microorganisms pose a serious threat for us humans, which is exemplified by the recent emergence of pathogens such as SARS-CoV-2 or the increasing number of multi-resistant pathogens such as MRSA. To control surface microorganisms and viruses, we investigated the disinfection properties of an AI-controlled robot, HERO21, equipped with eight 130-W low pressure UV-C mercury vapor discharge lamps emitting at a wavelength of 254 nm, which is strongly absorbed by DNA and RNA, thus inactivating illuminated microorganisms. Emissivity and spatial irradiance distribution of a single UV-C lamp unit was determined using a calibrated spectrometer and numerical simulation, respectively. The disinfection efficiency of single lamps is determined by microbiological tests using B. subtilis spores, which are known to be UV-C resistant. The required time for D99 disinfection and the corresponding UV-C irradiance dose amount to 60 s and 37.3 mJ•cm−2 at a distance of 1 m to the Hg-lamp, respectively. Spatially resolved irradiance produced by a disinfection unit consisting of eight lamps is calculated using results of one UV-C lamp characterization. This calculation shows that the UV-C robot HERO21 equipped with the mentioned UV-C unit causes an irradiance at λ=254 nm of 2.67 mJ•cm−2•s−1 at 1 m and 0.29 mJ•cm−2•s−1 at 3 m distances. These values result in D99 disinfection times of 14 s and 129 s for B. subtilis spores, respectively. Similarly, human coronavirus 229E, structurally very similar to SARS-CoV-2, could be efficiently inactivated by 3–5 orders of magnitude within 10 - 30 s exposure time or doses of 2 - 6 mJ•cm−2, respectively. In conclusion, with the development of the HERO21 disinfection robot, we were able to determine the inactivation efficiency of bacteria and viruses on surfaces under laboratory conditions.
Collapse
|
13
|
Polastri M, Pehlivan E. Preventing indoor contamination in private physiotherapy practices. INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION 2021. [DOI: 10.12968/ijtr.2021.0118] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Affiliation(s)
- Massimiliano Polastri
- Department of Continuity of Care and Disability, Physical Medicine and Rehabilitation, St Orsola University Hospital, Bologna, Italy
| | - Esra Pehlivan
- Department of Physical Therapy and Rehabilitation, University of Health Sciences Turkey, School of Health Sciences, Istanbul, Turkey
| |
Collapse
|