1
|
Raftery K, Rahman T, Smith N, Schaer T, Newell N. The role of the nucleus pulposus in intervertebral disc recovery: Towards improved specifications for nucleus replacement devices. J Biomech 2024; 166:111990. [PMID: 38383232 DOI: 10.1016/j.jbiomech.2024.111990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 01/26/2024] [Accepted: 02/07/2024] [Indexed: 02/23/2024]
Abstract
Nucleus replacement devices (NRDs) have potential to treat degenerated or herniated intervertebral discs (IVDs). However, IVD height loss is a post-treatment complication. IVD height recovery involves the nucleus pulposus (NP), but the mechanism of this in response to physiological loads is not fully elucidated. This study aimed to characterise the non-linear recovery behaviour of the IVD in intact, post-nuclectomy, and post-NRD treatment states, under physiological loading. 36 bovine IVDs (12 intact, 12 post-nuclectomy, 12 post-treatment) underwent creep-recovery protocols simulating Sitting, Walking or Running, followed by 12 h of recovery. A rheological model decoupled the fluid-independent (elastic, fast) and fluid-dependent (slow) recovery phases. In post-nuclectomy and post-treatment groups, nuclectomy efficiency (ratio of NP removed to remaining NP) was quantified following post-test sectioning. Relative to intact, post-nuclectomy recovery significantly decreased in Sitting (-0.3 ± 0.4 mm, p < 0.05) and Walking (-0.6 ± 0.3 mm, p < 0.001) coupled with significant decreases to the slow response (p < 0.05). Post-nuclectomy, the fast and slow responses negatively correlated with nuclectomy efficiency (p < 0.05). In all protocols, the post-treatment group performed significantly worse in recovery (-0.5 ± 0.3 mm, p < 0.01) and the slow response (p < 0.05). Results suggest the NP mainly facilitates slow-phase recovery, linearly dependent on the amount of NP present. Failure of this NRD to recover is attributed to poor fluid imbibition. Additionally, unconfined NRD performance cannot be extrapolated to the in vitro response. This knowledge informs NRD design criteria to provide high osmotic pressure, and encourages testing standards to incorporate long-term recovery protocols.
Collapse
Affiliation(s)
- K Raftery
- Department of Bioengineering, Imperial College London, London, UK
| | - T Rahman
- Department of Bioengineering, Imperial College London, London, UK; Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, UK
| | - N Smith
- Division of Surgery and Interventional Science, University College London, Stanmore, UK
| | - T Schaer
- Department of Clinical Studies New Bolton Center, University of Pennsylvania School of Veterinary Medicine, Kennett Square, PA, USA
| | - N Newell
- Department of Bioengineering, Imperial College London, London, UK.
| |
Collapse
|
2
|
Huber S, Santschi MXT, Schadow J, Leunig M, Ferguson SJ. Structure, composition and anisotropic swelling of the bovine acetabular labrum. J Mech Behav Biomed Mater 2024; 150:106333. [PMID: 38134586 DOI: 10.1016/j.jmbbm.2023.106333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 12/14/2023] [Accepted: 12/15/2023] [Indexed: 12/24/2023]
Abstract
The fibro-cartilaginous labrum surrounds the acetabular rim and is important for hip joint stability and sealing. Sealing may be enhanced by swelling pressure within the normal labrum. Swelling of the degenerated or torn labrum might occur and potentially contribute to the development of osteoarthritis, through altered load transmission. This study aimed to characterize the three-dimensional swelling behaviour, the collagen fiber orientation and spatial proteoglycan distribution of the bovine acetabular labrum. Specimens were harvested from bovine donors (192-652 days, male, n = 6 donors). Structure was analyzed by scanning electron microscopy, histology, and dimethylmethylene blue assay. Specimen dimensions were measured before and after incubation in phosphate buffered saline to assess the swelling. Results showed that the articulating surface is composed of a collagen mesh network. Collagen fiber bundles showed a low degree of alignment close to the surface and were circumferentially aligned in the deep tissue. Proteoglycans were identified clustered between the collagen bundles. Glycosaminoglycan content was 10 x lower than that of cartilage (23.1 ± 6.4 compared to 299.5 ± 19.1 μg/mg dry weight) with minor regional differences. Specimens swelled significantly more in the orthogonal direction (swelling ratio 124.7 ± 10.2%) compared to the swelling parallel to the articulating surface (108.8 ± 6.1% and 102.8 ± 4.1%). In the deep tissue, swelling was also restricted in the main collagen fiber bundle direction (circumferentially), with a swelling ratio of 109.5 ± 4.0% in the main fiber bundle direction compared to 126.8 ± 7.3 % and 122.3 ± 5.8% radially. The findings demonstrate that the labrum shows anisotropic swelling properties, which reflect the anisotropy in the tissue structure and inter-fiber localisation of proteoglycans.
Collapse
Affiliation(s)
- Stephanie Huber
- ETH Zurich, Institute for Biomechanics, Zurich, Switzerland.
| | | | - Jemima Schadow
- ETH Zurich, Institute for Biomechanics, Zurich, Switzerland.
| | - Michael Leunig
- Schulthess Klinik, Department of Hip Surgery, Zurich, Switzerland.
| | | |
Collapse
|
3
|
Lim S, Huff RD, Veres JE, Satish D, O'Connell GD. Disc geometry measurement methods affect reported compressive mechanics by up to 65%. JOR Spine 2022; 5:e1214. [PMID: 36203862 PMCID: PMC9520764 DOI: 10.1002/jsp2.1214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 05/04/2022] [Accepted: 06/17/2022] [Indexed: 11/10/2022] Open
Abstract
Mechanical testing is a valuable tool for assessing intervertebral disc health, but the wide range of testing protocols makes it difficult to compare results from different studies. Normalizing mechanical properties by disc geometry allows for such comparisons, but there is little consistency in the methods by which disc geometry is measured. As such, we hypothesized that methods used to measure disc geometry would impact reported mechanical properties. Disc height and area were measured using computed tomography (CT), digital calipers, and ImageJ to yield three different measurements for disc height and six for disc area. Disc heights measured by digital calipers ex situ were >30% less than disc heights measured in situ by CT, and disc areas measured ex situ using ImageJ were >30% larger than those measured by CT. This significantly affected reported mechanical properties, leading to a 65% reduction in normalized compressive stiffness in the most extreme case. Though we cannot quantitatively correct between methods, results presented in this study suggest that disc geometry measurement methods have a significant impact on normalized mechanical properties and should be accounted for when comparing results.
Collapse
Affiliation(s)
- Shiyin Lim
- Department of Mechanical Engineering University of California, Berkeley Berkeley California USA
| | - Reece D. Huff
- Department of Mechanical Engineering University of California, Berkeley Berkeley California USA
| | - Joanna E. Veres
- Department of Bioengineering University of California, Berkeley Berkeley California USA
| | - Divya Satish
- Department of Bioengineering University of California, Berkeley Berkeley California USA
| | - Grace D. O'Connell
- Department of Mechanical Engineering University of California, Berkeley Berkeley California USA
- Department of Orthopaedic Surgery University of California, San Francisco San Francisco California USA
| |
Collapse
|
4
|
Werbner B, Lee M, Lee A, Yang L, Habib M, Fields AJ, O'Connell GD. Non-enzymatic glycation of annulus fibrosus alters tissue-level failure mechanics in tension. J Mech Behav Biomed Mater 2022; 126:104992. [PMID: 34864399 DOI: 10.1016/j.jmbbm.2021.104992] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 11/18/2021] [Accepted: 11/18/2021] [Indexed: 10/19/2022]
Abstract
Advanced-glycation end products (AGEs) are known to accumulate in biological tissues with age and at an accelerated rate in patients with diabetes and chronic kidney disease. Clinically, diabetes has been linked to increased frequency and severity of back pain, accelerated disc degeneration, and an increased risk of disc herniation. Despite significant clinical evidence suggesting that diabetes-induced AGEs may play a role in intervertebral disc failure and substantial previous work investigating the effects of AGEs on bone, cartilage, and tendon mechanics, the effects of AGEs on annulus fibrosus (AF) failure mechanics have not yet been reported. Thus, the aim of this study was to determine the relationship between physiological levels of AGEs and AF tensile mechanics at two distinct loading rates. In vitro glycation treatments with methylglyoxal were applied to minimize changes in tissue hydration and induce two distinct levels of AGEs based on values measured from human AF tissues. In vitro glycation increased modulus by 48-99% and failure stress by 45-104% versus control and decreased post-failure energy absorption capacity by 15-32% versus control (ANOVA p < 0.0001 on means; range given across two loading rates and glycation levels). AGE content correlated strongly with modulus (R = 0.74, p < 0.0001) and failure stress (R = 0.70, p < 0.0001) and moderately with post-failure energy absorption capacity (R = 0.62, p < 0.0001). Failure strain was reduced by 10-17% at the high-glycation level (ANOVA p = 0.01). Tissue water content remained near or just above fresh-tissue levels for all groups. The alterations in mechanics with glycation reported here are consistent with trends from other connective tissues but do not fully explain the clinical predisposition of diabetics to disc herniation. The results from this study may be used in the development of advanced computational models that aim to study disc disease progression and to provide a deeper understanding of altered structure-function relationships that may lead to tissue dysfunction and failure with aging and disease.
Collapse
Affiliation(s)
- Benjamin Werbner
- Department of Mechanical Engineering University of California, Berkeley, USA
| | - Matthew Lee
- Department of Mechanical Engineering University of California, Berkeley, USA
| | - Allan Lee
- Department of Bioengineering University of California, Berkeley, USA
| | - Linda Yang
- Department of Bioengineering University of California, Berkeley, USA
| | - Mohamed Habib
- Department of Orthopaedic Surgery University of California, San Francisco, USA; Mechanical Engineering Department Al Azhar University, Cairo, Egypt
| | - Aaron J Fields
- Department of Orthopaedic Surgery University of California, San Francisco, USA
| | - Grace D O'Connell
- Department of Mechanical Engineering University of California, Berkeley, USA; Department of Orthopaedic Surgery University of California, San Francisco, USA.
| |
Collapse
|
5
|
Werbner B, Zhou M, McMindes N, Lee A, Lee M, O'Connell GD. Saline-polyethylene glycol blends preserve in vitro annulus fibrosus hydration and mechanics: An experimental and finite-element analysis. J Mech Behav Biomed Mater 2021; 125:104951. [PMID: 34749204 DOI: 10.1016/j.jmbbm.2021.104951] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 10/23/2021] [Accepted: 10/27/2021] [Indexed: 01/01/2023]
Abstract
Precise control of tissue water content is essential for ensuring accurate, repeatable, and physiologically relevant measurements of tissue mechanics and biochemical composition. While previous studies have found that saline and polyethylene glycol (PEG) blends were effective at controlling tendon and ligament hydration levels, this work has yet to be extended to the annulus fibrosus (AF). Thus, the first objective of this study was to determine and validate an optimal buffer solution for targeting and maintaining hydration levels of tissue-level AF specimens in vitro. This was accomplished by measuring the transient swelling behavior of bovine AF specimens in phosphate-buffered saline (PBS) and PEG buffers across a wide range of concentrations. Sub-failure, failure, and post-failure mechanics were measured to determine the relationship between changes in tissue hydration and tensile mechanical response. The effect of each buffer solution on tissue composition was also assessed. The second objective of this study was to assess the feasibility and effectiveness of using multi-phasic finite element models to investigate tissue swelling and mechanical responses in different external buffer solutions. A solution containing 6.25%w/v PBS and 6.25%w/v PEG effectively maintained tissue-level AF specimen hydration at fresh-frozen levels after 18 h in solution. Modulus, failure stress, failure strain, and post-failure toughness of specimens soaked in this solution for 18 h closely matched those of fresh-frozen specimens. In contrast, specimens soaked in 0.9%w/v PBS swelled over 100% after 18 h and exhibited significantly diminished sub-failure and failure properties compared to fresh-frozen controls. The increased cross-sectional area with swelling contributed to but was not sufficient to explain the diminished mechanics of PBS-soaked specimens, suggesting additional sub-tissue scale mechanisms. Computational simulations of these specimens generally agreed with experimental results, highlighting the feasibility and importance of including a fluid-phase description when models aim to provide accurate predictions of biological tissue responses. As numerous previous studies suggest that tissue hydration plays a central role in maintaining proper mechanical and biological function, robust methods for controlling hydration levels are essential as the field advances in probing the relationship between tissue hydration, aging, injury, and disease.
Collapse
Affiliation(s)
- Benjamin Werbner
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Minhao Zhou
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Nicole McMindes
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Allan Lee
- Department of Bioengineering, University of California, Berkeley, USA
| | - Matthew Lee
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Grace D O'Connell
- Department of Mechanical Engineering, University of California, Berkeley, USA; Department of Orthopaedic Surgery, University of California, San Francisco, USA.
| |
Collapse
|
6
|
Zhou M, Lim S, O’Connell GD. A Robust Multiscale and Multiphasic Structure-Based Modeling Framework for the Intervertebral Disc. Front Bioeng Biotechnol 2021; 9:685799. [PMID: 34164388 PMCID: PMC8215504 DOI: 10.3389/fbioe.2021.685799] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 05/10/2021] [Indexed: 12/11/2022] Open
Abstract
A comprehensive understanding of multiscale and multiphasic intervertebral disc mechanics is crucial for designing advanced tissue engineered structures aiming to recapitulate native tissue behavior. The bovine caudal disc is a commonly used human disc analog due to its availability, large disc height and area, and similarities in biochemical and mechanical properties to the human disc. Because of challenges in directly measuring subtissue-level mechanics, such as in situ fiber mechanics, finite element models have been widely employed in spinal biomechanics research. However, many previous models use homogenization theory and describe each model element as a homogenized combination of fibers and the extrafibrillar matrix while ignoring the role of water content or osmotic behavior. Thus, these models are limited in their ability in investigating subtissue-level mechanics and stress-bearing mechanisms through fluid pressure. The objective of this study was to develop and validate a structure-based bovine caudal disc model, and to evaluate multiscale and multiphasic intervertebral disc mechanics under different loading conditions and with degeneration. The structure-based model was developed based on native disc structure, where fibers and matrix in the annulus fibrosus were described as distinct materials occupying separate volumes. Model parameters were directly obtained from experimental studies without calibration. Under the multiscale validation framework, the model was validated across the joint-, tissue-, and subtissue-levels. Our model accurately predicted multiscale disc responses for 15 of 16 cases, emphasizing the accuracy of the model, as well as the effectiveness and robustness of the multiscale structure-based modeling-validation framework. The model also demonstrated the rim as a weak link for disc failure, highlighting the importance of keeping the cartilage endplate intact when evaluating disc failure mechanisms in vitro. Importantly, results from this study elucidated important fluid-based load-bearing mechanisms and fiber-matrix interactions that are important for understanding disease progression and regeneration in intervertebral discs. In conclusion, the methods presented in this study can be used in conjunction with experimental work to simultaneously investigate disc joint-, tissue-, and subtissue-level mechanics with degeneration, disease, and injury.
Collapse
Affiliation(s)
- Minhao Zhou
- Berkeley Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA, United States
| | - Shiyin Lim
- Berkeley Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA, United States
| | - Grace D. O’Connell
- Berkeley Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA, United States
- Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, CA, United States
| |
Collapse
|
7
|
Costi JJ, Ledet EH, O'Connell GD. Spine biomechanical testing methodologies: The controversy of consensus vs scientific evidence. JOR Spine 2021; 4:e1138. [PMID: 33778410 PMCID: PMC7984003 DOI: 10.1002/jsp2.1138] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 12/04/2020] [Accepted: 12/07/2020] [Indexed: 12/14/2022] Open
Abstract
Biomechanical testing methodologies for the spine have developed over the past 50 years. During that time, there have been several paradigm shifts with respect to techniques. These techniques evolved by incorporating state-of-the-art engineering principles, in vivo measurements, anatomical structure-function relationships, and the scientific method. Multiple parametric studies have focused on the effects that the experimental technique has on outcomes. As a result, testing methodologies have evolved, but there are no standard testing protocols, which makes the comparison of findings between experiments difficult and conclusions about in vivo performance challenging. In 2019, the international spine research community was surveyed to determine the consensus on spine biomechanical testing and if the consensus opinion was consistent with the scientific evidence. More than 80 responses to the survey were received. The findings of this survey confirmed that while some methods have been commonly adopted, not all are consistent with the scientific evidence. This review summarizes the scientific literature, the current consensus, and the authors' recommendations on best practices based on the compendium of available evidence.
Collapse
Affiliation(s)
- John J. Costi
- Biomechanics and Implants Research Group, Medical Device Research Institute, College of Science and EngineeringFlinders UniversityAdelaideAustralia
| | - Eric H. Ledet
- Department of Biomedical EngineeringRensselaer Polytechnic InstituteTroyNew YorkUSA
- Research and Development ServiceStratton VA Medical CenterAlbanyNew YorkUSA
| | - Grace D. O'Connell
- Department of Mechanical EngineeringUniversity of California‐BerkeleyBerkeleyCaliforniaUSA
- Department of Orthopaedic SurgeryUniversity of California‐San FranciscoSan FranciscoCaliforniaUSA
| |
Collapse
|