1
|
Assländer J, Flassbeck S. Magnetization transfer explains most of the T 1 variability in the MRI literature. Magn Reson Med 2025; 94:293-301. [PMID: 40096551 PMCID: PMC12021565 DOI: 10.1002/mrm.30451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Revised: 01/05/2025] [Accepted: 01/15/2025] [Indexed: 03/19/2025]
Abstract
PURPOSE To identify the predominant source of theT 1 $$ {T}_1 $$ variability described in the literature, which ranges from 0.6-1.1 s for brain white matter at 3 T. METHODS 25T 1 $$ {T}_1 $$ -mapping methods from the literature were simulated with a mono-exponential and various magnetization-transfer (MT) models, each followed by mono-exponential fitting. A single set of model parameters was assumed for the simulation of all methods, and these parameters were estimated by fitting the simulation-based to the corresponding literatureT 1 $$ {T}_1 $$ values of white matter at 3 T. We acquired in vivo data with a quantitative magnetization transfer and threeT 1 $$ {T}_1 $$ -mapping techniques. The former was used to synthesize MR images that correspond to the threeT 1 $$ {T}_1 $$ -mapping methods. A mono-exponential model was fitted to the experimental and corresponding synthesized MR images. RESULTS Mono-exponential simulations suggest good inter-method reproducibility and fail to explain the highly variableT 1 $$ {T}_1 $$ estimates in the literature. In contrast, MT simulations suggest that a mono-exponential fit results in a variableT 1 $$ {T}_1 $$ and explain up to 62% of the literature's variability. In our own in vivo experiments, MT explains 70% of the observed variability. CONCLUSION The results suggest that a mono-exponential model does not adequately describe longitudinal relaxation in biological tissue. Therefore,T 1 $$ {T}_1 $$ in biological tissue should be considered only a semi-quantitative metric that is inherently contingent upon the imaging methodology, and comparisons between differentT 1 $$ {T}_1 $$ -mapping methods and the use of simplistic spin systems-such as doped-water phantoms-for validation should be viewed with caution.
Collapse
Affiliation(s)
- Jakob Assländer
- Center for Biomedical Imaging, Dept. of Radiology, NYU
School of Medicine, NY, USA
- Center for Advanced Imaging Innovation and Research
(CAI2R), Dept. of Radiology, NYU School of Medicine, NY, USA
| | - Sebastian Flassbeck
- Center for Biomedical Imaging, Dept. of Radiology, NYU
School of Medicine, NY, USA
- Center for Advanced Imaging Innovation and Research
(CAI2R), Dept. of Radiology, NYU School of Medicine, NY, USA
| |
Collapse
|
2
|
Lee CH, Holloman M, Salzer JL, Zhang J. Multiparametric MRI Can Detect Enhanced Myelination in the Ex Vivo Gli1 -/- Mouse Brain. NMR IN BIOMEDICINE 2025; 38:e70025. [PMID: 40174963 DOI: 10.1002/nbm.70025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 03/06/2025] [Accepted: 03/20/2025] [Indexed: 04/04/2025]
Abstract
This study investigated the potential of combining multiple MR parameters to enhance the characterization of myelin in the mouse brain. We collected ex vivo multiparametric MR data at 7 T from control and Gli1-/- mice; the latter exhibit enhanced myelination at Postnatal Day 10 (P10) in the corpus callosum and cortex. The MR data included relaxivity, magnetization transfer, and diffusion measurements, each targeting distinct myelin properties. This analysis was followed by and compared to myelin basic protein (MBP) staining of the same samples. Although a majority of the MR parameters included in this study showed significant differences in the corpus callosum between the control and Gli1-/- mice, only T2, T1/T2, and radial diffusivity (RD) demonstrated a significant correlation with MBP values. Based on data from the corpus callosum, partial least square regression suggested that combining T2, T1/T2, and inhomogeneous magnetization transfer ratio could explain approximately 80% of the variance in the MBP values. Myelin predictions based on these three parameters yielded stronger correlations with the MBP values in the P10 mouse brain corpus callosum than any single MR parameter. In the motor cortex, combining T2, T1/T2, and radial kurtosis could explain over 90% of the variance in the MBP values at P10. This study demonstrates the utility of multiparametric MRI in improving the detection of myelin changes in the mouse brain.
Collapse
Affiliation(s)
- Choong H Lee
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Mara Holloman
- Department of Neuroscience and Physiology, Neuroscience Institute, New York University Grossman School of Medicine, New York, New York, USA
| | - James L Salzer
- Department of Neuroscience and Physiology, Neuroscience Institute, New York University Grossman School of Medicine, New York, New York, USA
| | - Jiangyang Zhang
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| |
Collapse
|
3
|
Hagiwara A, Kamio S, Kikuta J, Nakaya M, Uchida W, Fujita S, Nikola S, Akasahi T, Wada A, Kamagata K, Aoki S. Decoding Brain Development and Aging: Pioneering Insights From MRI Techniques. Invest Radiol 2025; 60:162-174. [PMID: 39724579 PMCID: PMC11801466 DOI: 10.1097/rli.0000000000001120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Accepted: 07/26/2024] [Indexed: 12/28/2024]
Abstract
ABSTRACT The aging process induces a variety of changes in the brain detectable by magnetic resonance imaging (MRI). These changes include alterations in brain volume, fluid-attenuated inversion recovery (FLAIR) white matter hyperintense lesions, and variations in tissue properties such as relaxivity, myelin, iron content, neurite density, and other microstructures. Each MRI technique offers unique insights into the structural and compositional changes occurring in the brain due to normal aging or neurodegenerative diseases. Age-related brain volume changes encompass a decrease in gray matter and an increase in ventricular volume, associated with cognitive decline. White matter hyperintensities, detected by FLAIR, are common and linked to cognitive impairments and increased risk of stroke and dementia. Tissue relaxometry reveals age-related changes in relaxivity, aiding the distinction between normal aging and pathological conditions. Myelin content, measurable by MRI, changes with age and is associated with cognitive and motor function alterations. Iron accumulation, detected by susceptibility-sensitive MRI, increases in certain brain regions with age, potentially contributing to neurodegenerative processes. Diffusion MRI provides detailed insights into microstructural changes such as neurite density and orientation. Neurofluid imaging, using techniques like gadolinium-based contrast agents and diffusion MRI, reveals age-related changes in cerebrospinal and interstitial fluid dynamics, crucial for brain health and waste clearance. This review offers a comprehensive overview of age-related brain changes revealed by various MRI techniques. Understanding these changes helps differentiate between normal aging and pathological conditions, aiding the development of interventions to mitigate age-related cognitive decline and other symptoms. Recent advances in machine learning and artificial intelligence have enabled novel methods for estimating brain age, offering also potential biomarkers for neurological and psychiatric disorders.
Collapse
|
4
|
Karan P, Edde M, Gilbert G, Barakovic M, Magon S, Descoteaux M. Characterization of the orientation dependence of magnetization transfer measures in single and crossing-fiber white matter. Magn Reson Med 2024; 92:2207-2221. [PMID: 38924176 DOI: 10.1002/mrm.30195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 04/23/2024] [Accepted: 05/25/2024] [Indexed: 06/28/2024]
Abstract
PURPOSE To fully characterize the orientation dependence of magnetization transfer (MT) and inhomogeneous MT (ihMT) measures in the whole white matter (WM), for both single-fiber and crossing-fiber voxels. METHODS A characterization method was developed using the fiber orientation obtained from diffusion MRI (dMRI) with diffusion tensor imaging (DTI) and constrained spherical deconvolution. This allowed for characterization of the orientation dependence of measures in all of WM, regardless of the number of fiber orientation in a voxel. Furthermore, the orientation dependence inside 31 different WM bundles was characterized to evaluate the homogeneity of the effect. Variation of the results within and between-subject was assessed from a 12-subject dataset. RESULTS Previous results for single-fiber voxels were reproduced and a novel characterization was produced in voxels of crossing fibers, which seems to follow trends consistent with single-fiber results. Heterogeneity of the orientation dependence across bundles was observed, but homogeneity within similar bundles was also highlighted. Differences in behavior between MT and ihMT measures, as well as the ratio and saturation versions of these, were noted. CONCLUSION Orientation dependence characterization was proven possible over the entirety of WM. The vast range of effects and subtleties of the orientation dependence on MT measures showed the need for, but also the challenges of, a correction method.
Collapse
Affiliation(s)
- Philippe Karan
- Sherbrooke Connectivity Imaging Laboratory (SCIL), Université de Sherbrooke, Sherbrooke, Canada
| | - Manon Edde
- Sherbrooke Connectivity Imaging Laboratory (SCIL), Université de Sherbrooke, Sherbrooke, Canada
| | | | - Muhamed Barakovic
- Pharma Research and Early Development, Neuroscience and Rare Diseases Roche Innovation Center Basel, Basel, Switzerland
| | - Stefano Magon
- Pharma Research and Early Development, Neuroscience and Rare Diseases Roche Innovation Center Basel, Basel, Switzerland
| | - Maxime Descoteaux
- Sherbrooke Connectivity Imaging Laboratory (SCIL), Université de Sherbrooke, Sherbrooke, Canada
| |
Collapse
|
5
|
Sun Z, Saunders SR. Impacts of Small SBA-15 Mesopores on Translation and Rotational Diffusion of Benzyl Alcohol. J Phys Chem B 2024; 128:9561-9572. [PMID: 39292547 DOI: 10.1021/acs.jpcb.4c05966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/20/2024]
Abstract
Small SBA-15 pores can enhance the catalytic activity of gold catalysts in the selective oxidation of benzyl alcohol reaction. The goal of this work is to probe the impact of SBA-15 pores on the translational and rotational diffusion of the reactive species (e.g., benzyl alcohol). Herein, we demonstrate the use of nuclear magnetic resonance-based diffusion-ordered spectroscopy (DOSY) and T1 relaxation techniques to measure the translational and rotational diffusion coefficients of liquid benzyl alcohol molecules in three distinct environments: bulk, pore, and near-surface. The DOSY and T1 relaxation techniques render the routine diffusion measurements for liquid molecules confined in small pores possible. Furthermore, we measure the translational and rotational diffusion coefficients of benzyl alcohol molecules in the bulk, pore, and near-surface environments at varying temperatures. These measurements are then correlated via the Arrhenius equation to determine the activation energy associated with their translational (Et) and rotational (Er) diffusion. A higher activation energy suggests a more difficult diffusion process, while a lower activation energy implies a facile diffusion process. Our findings demonstrate that the ranking of Et follows the order of bulk (difficult) > near-surface > pore (easy), whereas the ranking of Er follows the order of pore (difficult) > bulk > near-surface (easy). This result suggests that the small SBA-15 pores can facilitate the translational diffusion but hinder the rotational diffusion of benzyl alcohol molecules.
Collapse
Affiliation(s)
- Zengran Sun
- The Gene and Linda Voilanad School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
| | - Steven R Saunders
- The Gene and Linda Voilanad School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
| |
Collapse
|
6
|
Zhou Z, Xu Z, Lai W, Chen X, Zeng L, Qian L, Liu X, Jiang W, Zhang Y, Hou G. Reduced myelin content in bipolar disorder: A study of inhomogeneous magnetization transfer. J Affect Disord 2024; 356:363-370. [PMID: 38615848 DOI: 10.1016/j.jad.2024.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 03/19/2024] [Accepted: 04/03/2024] [Indexed: 04/16/2024]
Abstract
BACKGROUND Previous neuroimaging and pathological studies have found myelin-related abnormalities in bipolar disorder (BD), which prompted the use of magnetic resonance (MR) imaging technology sensitive to neuropathological changes to explore its neuropathological basis. We holistically investigated alterations in myelin within BD patients by inhomogeneous magnetization transfer (ihMT), which is sensitive and specific to myelin content. METHODS Thirty-one BD and 42 healthy controls (HC) were involved. Four MR metrics, i.e., ihMT ratio (ihMTR), pseudo-quantitative ihMT (qihMT), magnetization transfer ratio and pseudo-quantitative magnetization transfer (qMT), were compared between groups using analysis methods based on whole-brain voxel-level and white matter regions of interest (ROI), respectively. RESULTS The voxel-wise analysis showed significantly inter-group differences of ihMTR and qihMT in the corpus callosum. The ROI-wise analysis showed that ihMTR, qihMT, and qMT values in BD group were significantly lower than that in HC group in the genu and body of corpus callosum, left anterior limb of the internal capsule, left anterior corona radiate, and bilateral cingulum (p < 0.001). And the qihMT in genu of corpus callosum and right cingulum were negatively correlated with depressive symptoms in BD group. LIMITATIONS This study is based on cross-sectional data and the sample size is limited. CONCLUSION These findings suggest the reduced myelin content of anterior midline structure in the bipolar patients, which might be a critical pathophysiological feature of BD.
Collapse
Affiliation(s)
- Zhifeng Zhou
- Neuropsychiatry Imaging Center, Department of Radiology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China
| | - Ziyun Xu
- Neuropsychiatry Imaging Center, Department of Radiology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China
| | - Wentao Lai
- Neuropsychiatry Imaging Center, Department of Radiology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China
| | - Xiaoqiao Chen
- Neuropsychiatry Imaging Center, Department of Radiology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China
| | - Lin Zeng
- Neuropsychiatry Imaging Center, Department of Radiology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China
| | - Long Qian
- MR Research, GE Healthcare, Beijing 100176, China
| | - Xia Liu
- Neuropsychiatry Imaging Center, Department of Radiology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China
| | - Wentao Jiang
- Neuropsychiatry Imaging Center, Department of Radiology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China
| | - Yingli Zhang
- Department of Psychology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China.
| | - Gangqiang Hou
- Neuropsychiatry Imaging Center, Department of Radiology, Shenzhen Mental Health Center, Shenzhen Kangning Hospital, Shenzhen 518118, China.
| |
Collapse
|
7
|
Lee CH, Holloman M, Salzer JL, Zhang J. Multi-parametric MRI can detect enhanced myelination in the Gli1 -/- mouse brain. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2023.11.20.567957. [PMID: 38045415 PMCID: PMC10690149 DOI: 10.1101/2023.11.20.567957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
This study investigated the potential of combining multiple MR parameters to enhance the characterization of myelin in the mouse brain. We collected ex vivo multi-parametric MR data at 7 Tesla from control and Gli1 -/- mice; the latter exhibit enhanced myelination at postnatal day 10 (P10) in the corpus callosum and cortex. The MR data included relaxivity, magnetization transfer, and diffusion measurements, each targeting distinct myelin properties. This analysis was followed by and compared to myelin basic protein (MBP) staining of the same samples. Although a majority of the MR parameters included in this study showed significant differences in the corpus callosum between the control and Gli1 -/- mice, only T 2 , T 1 /T 2, and radial diffusivity (RD) demonstrated a significant correlation with MBP values. Based on data from the corpus callosum, partial least square regression suggested that combining T 2 , T 1 /T 2 , and inhomogeneous magnetization transfer ratio could explain approximately 80% of the variance in the MBP values. Myelin predictions based on these three parameters yielded stronger correlations with the MBP values in the P10 mouse brain corpus callosum than any single MR parameter. In the motor cortex, combining T 2 , T 1 /T 2, and radial kurtosis could explain over 90% of the variance in the MBP values at P10. This study demonstrates the utility of multi-parametric MRI in improving the detection of myelin changes in the mouse brain.
Collapse
|
8
|
Assländer J, Gultekin C, Mao A, Zhang X, Duchemin Q, Liu K, Charlson RW, Shepherd TM, Fernandez-Granda C, Flassbeck S. Rapid quantitative magnetization transfer imaging: Utilizing the hybrid state and the generalized Bloch model. Magn Reson Med 2024; 91:1478-1497. [PMID: 38073093 PMCID: PMC12056700 DOI: 10.1002/mrm.29951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 10/30/2023] [Accepted: 11/14/2023] [Indexed: 02/03/2024]
Abstract
PURPOSE To explore efficient encoding schemes for quantitative magnetization transfer (qMT) imaging with few constraints on model parameters. THEORY AND METHODS We combine two recently proposed models in a Bloch-McConnell equation: the dynamics of the free spin pool are confined to the hybrid state, and the dynamics of the semi-solid spin pool are described by the generalized Bloch model. We numerically optimize the flip angles and durations of a train of radio frequency pulses to enhance the encoding of three qMT parameters while accounting for all eight parameters of the two-pool model. We sparsely sample each time frame along this spin dynamics with a three-dimensional radial koosh-ball trajectory, reconstruct the data with subspace modeling, and fit the qMT model with a neural network for computational efficiency. RESULTS We extracted qMT parameter maps of the whole brain with an effective resolution of 1.24 mm from a 12.6-min scan. In lesions of multiple sclerosis subjects, we observe a decreased size of the semi-solid spin pool and longer relaxation times, consistent with previous reports. CONCLUSION The encoding power of the hybrid state, combined with regularized image reconstruction, and the accuracy of the generalized Bloch model provide an excellent basis for efficient quantitative magnetization transfer imaging with few constraints on model parameters.
Collapse
Affiliation(s)
- Jakob Assländer
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, NYU School of Medicine, New York, New York, USA
| | - Cem Gultekin
- Courant Institute of Mathematical Sciences, New York University, New York, New York, USA
| | - Andrew Mao
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, NYU School of Medicine, New York, New York, USA
- Vilcek Institute of Graduate Biomedical Sciences, NYU School of Medicine, New York, New York, USA
| | - Xiaoxia Zhang
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, NYU School of Medicine, New York, New York, USA
| | - Quentin Duchemin
- Laboratoire d’analyse et de mathématiques appliquées, Université Gustave Eiffel, Champs-sur-Marne, France
| | - Kangning Liu
- Center for Data Science, New York University, New York, New York, USA
| | - Robert W. Charlson
- Department of Neurology, NYU School of Medicine, New York, New York, USA
| | - Timothy M. Shepherd
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
| | - Carlos Fernandez-Granda
- Courant Institute of Mathematical Sciences, New York University, New York, New York, USA
- Center for Data Science, New York University, New York, New York, USA
| | - Sebastian Flassbeck
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA
- Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, NYU School of Medicine, New York, New York, USA
| |
Collapse
|
9
|
Khormi I, Al-Iedani O, Alshehri A, Ramadan S, Lechner-Scott J. MR myelin imaging in multiple sclerosis: A scoping review. J Neurol Sci 2023; 455:122807. [PMID: 38035651 DOI: 10.1016/j.jns.2023.122807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 10/20/2023] [Accepted: 11/19/2023] [Indexed: 12/02/2023]
Abstract
The inability of disease-modifying therapies to stop the progression of multiple sclerosis (MS), has led to the development of a new therapeutic strategy focussing on myelin repair. While conventional MRI lacks sensitivity for quantifying myelin damage, advanced MRI techniques are proving effective. The development of targeted therapeutics requires histological validation of myelin imaging results, alongside the crucial task of establishing correlations between myelin imaging results and clinical assessments, so that the effectiveness of therapeutic interventions can be evaluated. The aims of this scoping review were to identify myelin imaging methods - some of which have been histologically validated, and to determine how these approaches correlate with clinical assessments of people with MS (pwMS), thus allowing for effective therapeutic evaluation. A search of two databases was undertaken for publications relating to studies on adults MS using either MRI/MR-histology of the MS brain in the range 1990-to-2022. The myelin imaging methods specified were relaxometry, magnetization transfer, and quantitative susceptibility. Relaxometry was used most frequently, with myelin water fraction (MWF) being the primary metric. Studies conducted on tissue from various regions of the brain showed that MWF was significantly lower in pwMS than in healthy controls. Magnetization transfer ratio indicated that the macromolecular content of lesions was lower than that of normal-appearing tissue. Higher magnetic susceptibility of lesions were indicative of myelin breakdown and iron accumulation. Several myelin imaging metrics were correlated with disability, disease severity and duration. Many studies showed a good correlation between myelin measured histologically and by MR myelin imaging techniques.
Collapse
Affiliation(s)
- Ibrahim Khormi
- School of Health Sciences, College of Health, Medicine and Wellbeing, University of Newcastle, Newcastle, Australia; Hunter Medical Research Institute, New Lambton Heights, Australia; College of Applied Medical Sciences, University of Jeddah, Jeddah, Saudi Arabia
| | - Oun Al-Iedani
- Hunter Medical Research Institute, New Lambton Heights, Australia; School of Biomedical Sciences and Pharmacy, College of Health, Medicine and Wellbeing, University of Newcastle, Newcastle, Australia
| | - Abdulaziz Alshehri
- School of Health Sciences, College of Health, Medicine and Wellbeing, University of Newcastle, Newcastle, Australia; Hunter Medical Research Institute, New Lambton Heights, Australia; Department of Radiology, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Saadallah Ramadan
- School of Health Sciences, College of Health, Medicine and Wellbeing, University of Newcastle, Newcastle, Australia; Hunter Medical Research Institute, New Lambton Heights, Australia.
| | - Jeannette Lechner-Scott
- Hunter Medical Research Institute, New Lambton Heights, Australia; Department of Neurology, John Hunter Hospital, New Lambton Heights, Australia; School of Medicine and Public Health, College of Health, Medicine and Wellbeing, University of Newcastle, Newcastle, Australia
| |
Collapse
|
10
|
Rowley CD, Campbell JSW, Leppert IR, Nelson MC, Pike GB, Tardif CL. Optimization of acquisition parameters for cortical inhomogeneous magnetization transfer (ihMT) imaging using a rapid gradient echo readout. Magn Reson Med 2023; 90:1762-1775. [PMID: 37332194 DOI: 10.1002/mrm.29754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/25/2023] [Accepted: 05/22/2023] [Indexed: 06/20/2023]
Abstract
PURPOSE Imaging biomarkers with increased myelin specificity are needed to better understand the complex progression of neurological disorders. Inhomogeneous magnetization transfer (ihMT) imaging is an emergent technique that has a high degree of specificity for myelin content but suffers from low signal to-noise ratio (SNR). This study used simulations to determine optimal sequence parameters for ihMT imaging for use in high-resolution cortical mapping. METHODS MT-weighted cortical image intensity and ihMT SNR were simulated using modified Bloch equations for a range of sequence parameters. The acquisition time was limited to 4.5 min/volume. A custom MT-weighted RAGE sequence with center-out k-space encoding was used to enhance SNR at 3 T. Pulsed MT imaging was studied over a range of saturation parameters, and the impact of the turbo factor on the effective ihMT resolution was investigated. 1 mm isotropic ihMTsat maps were generated in 25 healthy adults. RESULTS Greater SNR was observed for larger number of bursts consisting of 6-8 saturation pulses each, combined with a high readout turbo factor. However, that protocol suffered from a point spread function that was more than twice the nominal resolution. For high-resolution cortical imaging, we selected a protocol with a higher effective resolution at the cost of a lower SNR. We present the first group-average ihMTsat whole-brain map at 1 mm isotropic resolution. CONCLUSION This study presents the impact of saturation and excitation parameters on ihMTsat SNR and resolution. We demonstrate the feasibility of high-resolution cortical myelin imaging using ihMTsat in less than 20 min.
Collapse
Affiliation(s)
- Christopher D Rowley
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, McGill University, Montreal, Québec, Canada
- Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
| | - Jennifer S W Campbell
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, McGill University, Montreal, Québec, Canada
| | - Ilana R Leppert
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, McGill University, Montreal, Québec, Canada
| | - Mark C Nelson
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, McGill University, Montreal, Québec, Canada
- Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
| | - G Bruce Pike
- Hotchkiss Brain Institute and Departments of Radiology and Clinical Neuroscience, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Christine L Tardif
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, McGill University, Montreal, Québec, Canada
- Department of Neurology and Neurosurgery, McGill University, Montreal, Québec, Canada
- Department of Biomedical Engineering, McGill University, Montreal, Québec, Canada
| |
Collapse
|
11
|
Alsop DC, Ercan E, Girard OM, Mackay AL, Michal CA, Varma G, Vinogradov E, Duhamel G. Inhomogeneous magnetization transfer imaging: Concepts and directions for further development. NMR IN BIOMEDICINE 2023; 36:e4808. [PMID: 35916067 DOI: 10.1002/nbm.4808] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 07/27/2022] [Accepted: 07/28/2022] [Indexed: 05/23/2023]
Abstract
Off-resonance radio frequency irradiation can induce the ordering of proton spins in the dipolar fields of their neighbors, in molecules with restricted mobility. This dipolar order decays with a characteristic relaxation time, T1D , that is very different from the T1 and T2 relaxation of the nuclear alignment with the main magnetic field. Inhomogeneous magnetization transfer (ihMT) imaging is a refinement of magnetization transfer (MT) imaging that isolates the MT signal dependence on dipolar order relaxation times within motion-constrained molecules. Because T1D relaxation is a unique contrast mechanism, ihMT may enable improved characterization of tissue. Initial work has stressed the high correlation between ihMT signal and myelin density. Dipolar order relaxation appears to be much longer in membrane lipids than other molecules. Recent work has shown, however, that ihMT acquisitions may also be adjusted to emphasize different ranges of T1D . These newer approaches may be sensitive to other microstructural components of tissue. Here, we review the concepts and history of ihMT and outline the requirements for further development to realize its full potential.
Collapse
Affiliation(s)
- David C Alsop
- Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - Ece Ercan
- MR Clinical Science, Philips, Best, The Netherlands
| | | | - Alex L Mackay
- Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
- Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada
| | - Carl A Michal
- Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
| | - Gopal Varma
- Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | - Elena Vinogradov
- Department of Radiology and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA
| | | |
Collapse
|
12
|
Soustelle L, Troalen T, Hertanu A, Ranjeva JP, Guye M, Varma G, Alsop DC, Duhamel G, Girard OM. Quantitative magnetization transfer MRI unbiased by on-resonance saturation and dipolar order contributions. Magn Reson Med 2023. [PMID: 37154400 DOI: 10.1002/mrm.29678] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 03/22/2023] [Accepted: 04/01/2023] [Indexed: 05/10/2023]
Abstract
PURPOSE To demonstrate the bias in quantitative MT (qMT) measures introduced by the presence of dipolar order and on-resonance saturation (ONRS) effects using magnetization transfer (MT) spoiled gradient-recalled (SPGR) acquisitions, and propose changes to the acquisition and analysis strategies to remove these biases. METHODS The proposed framework consists of SPGR sequences prepared with simultaneous dual-offset frequency-saturation pulses to cancel out dipolar order and associated relaxation (T1D ) effects in Z-spectrum acquisitions, and a matched quantitative MT (qMT) mathematical model that includes ONRS effects of readout pulses. Variable flip angle and MT data were fitted jointly to simultaneously estimate qMT parameters (macromolecular proton fraction [MPF], T2,f , T2,b , R, and free pool T1 ). This framework is compared with standard qMT and investigated in terms of reproducibility, and then further developed to follow a joint single-point qMT methodology for combined estimation of MPF and T1 . RESULTS Bland-Altman analyses demonstrated a systematic underestimation of MPF (-2.5% and -1.3%, on average, in white and gray matter, respectively) and overestimation of T1 (47.1 ms and 38.6 ms, on average, in white and gray matter, respectively) if both ONRS and dipolar order effects are ignored. Reproducibility of the proposed framework is excellent (ΔMPF = -0.03% and ΔT1 = -19.0 ms). The single-point methodology yielded consistent MPF and T1 values with respective maximum relative average bias of -0.15% and -3.5 ms found in white matter. CONCLUSION The influence of acquisition strategy and matched mathematical model with regard to ONRS and dipolar order effects in qMT-SPGR frameworks has been investigated. The proposed framework holds promise for improved accuracy with reproducibility.
Collapse
Affiliation(s)
- Lucas Soustelle
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | | | - Andreea Hertanu
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Jean-Philippe Ranjeva
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Maxime Guye
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Gopal Varma
- Division of MR Research, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - David C Alsop
- Division of MR Research, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Guillaume Duhamel
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Olivier M Girard
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| |
Collapse
|
13
|
Morris SR, Vavasour IM, Smolina A, MacMillan EL, Gilbert G, Lam M, Kozlowski P, Michal CA, Manning A, MacKay AL, Laule C. Myelin biomarkers in the healthy adult brain: Correlation, reproducibility, and the effect of fiber orientation. Magn Reson Med 2023; 89:1809-1824. [PMID: 36511247 DOI: 10.1002/mrm.29552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 10/17/2022] [Accepted: 11/18/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE We investigated the correlation, reproducibility, and effect of white matter fiber orientation for three myelin-sensitive MRI techniques: magnetization transfer ratio (MTR), inhomogeneous magnetization transfer ratio (ihMTR), and gradient and spin echo-derived myelin water fraction (MWF). METHODS We measured the three metrics in 17 white and three deep grey matter regions in 17 healthy adults at 3 T. RESULTS We found a strong correlation between ihMTR and MTR (r = 0.70, p < 0.001) and ihMTR and MWF (r = 0.79, p < 0.001), and a weaker correlation between MTR and MWF (r = 0.54, p < 0.001). The dynamic range in white matter was greatest for MWF (2.0%-27.5%), followed by MTR (14.4%-23.2%) and then ihMTR (1.2%-5.4%). The average scan-rescan coefficient of variation for white matter regions was 0.6% MTR, 0.3% ihMTR, and 0.7% MWF in metric units; however, when adjusted by the dynamic range, these became 6.3%, 6.1% and 2.8%, respectively. All three metrics varied with fiber direction: MWF and ihMTR were lower in white matter fibers perpendicular to B0 by 6% and 1%, respectively, compared with those parallel, whereas MTR was lower by 0.5% at about 40°, with the highest values at 90°. However, separating the apparent orientation dependence by white matter region revealed large dissimilarities in the trends, suggesting that real differences in myelination between regions are confounding the apparent orientation dependence measured using this method. CONCLUSION The strong correlation between ihMTR and MWF suggests that these techniques are measuring the same myelination; however, the larger dynamic range of MWF may provide more power to detect small differences in myelin.
Collapse
Affiliation(s)
- Sarah R Morris
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada.,Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.,International Collaboration on Repair Discoveries, University of British Columbia, Vancouver, British Columbia, Canada
| | - Irene M Vavasour
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada.,International Collaboration on Repair Discoveries, University of British Columbia, Vancouver, British Columbia, Canada.,UBC MRI Research Center, University of British Columbia, Vancouver, British Columbia, Canada
| | - Anastasia Smolina
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Erin L MacMillan
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada.,UBC MRI Research Center, University of British Columbia, Vancouver, British Columbia, Canada.,MR Clinical Science, Philips Healthcare Canada, Mississauga, Ontario, Canada
| | - Guillaume Gilbert
- MR Clinical Science, Philips Healthcare Canada, Mississauga, Ontario, Canada
| | - Michelle Lam
- Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.,UBC MRI Research Center, University of British Columbia, Vancouver, British Columbia, Canada
| | - Piotr Kozlowski
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada.,Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.,International Collaboration on Repair Discoveries, University of British Columbia, Vancouver, British Columbia, Canada.,UBC MRI Research Center, University of British Columbia, Vancouver, British Columbia, Canada
| | - Carl A Michal
- Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
| | - Alan Manning
- Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
| | - Alex L MacKay
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada.,Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.,UBC MRI Research Center, University of British Columbia, Vancouver, British Columbia, Canada
| | - Cornelia Laule
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada.,Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.,International Collaboration on Repair Discoveries, University of British Columbia, Vancouver, British Columbia, Canada.,UBC MRI Research Center, University of British Columbia, Vancouver, British Columbia, Canada.,Pathology & Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
14
|
Yong X, Lu S, Hsu YC, Fu C, Sun Y, Zhang Y. Numerical fitting of Extrapolated semisolid Magnetization transfer Reference signals: Improved detection of ischemic stroke. Magn Reson Med 2023; 90:722-736. [PMID: 37052377 DOI: 10.1002/mrm.29660] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 03/09/2023] [Accepted: 03/18/2023] [Indexed: 04/14/2023]
Abstract
PURPOSE To propose a novel Numerical fitting method of the Extrapolated semisolid Magnetization transfer Reference (NEMR) signal for quantifying the CEST effect. THEORY AND METHODS Modified two-pool Bloch-McConnell equations were used to numerically fit the magnetization transfer (MT) and direct water saturation (DS) signals at far off-resonance frequencies, which was subsequently extrapolated into the frequency range of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) pools. Then the subtraction of the fitted two-pool z-spectrum and the experimentally acquired z-spectrum yielded APT# and NOE# signals mostly free of MT and DS contamination. Several strategies were used to accelerate the NEMR fitting. Furthermore, the proposed NEMR method was compared with the conventional extrapolated semisolid magnetization transfer reference (EMR) and magnetization transfer ratio asymmetry (MTRasym ) methods in simulations and stroke patients. RESULTS The combination of RF downsampling, MT lineshape look-up table, and conversion of MATLAB code to C code accelerated the NEMR fitting by over 2700-fold. Monte-Carlo simulations showed that NEMR had higher accuracy than EMR and eliminated the requirement of the steady-state condition. In ischemic stroke patients, the NEMR maps at 1 μT removed hypointense artifacts seen on EMR and MTRasym images, and better depicted stroke lesions than EMR. For NEMR, NOE# yielded significantly (p < 0.05) stronger signal contrast between stroke and normal tissues than APT# at 1 μT. CONCLUSION The proposed NEMR method is suitable for arbitrary saturation settings and can remove MT and DS contamination from the CEST signal for improved detection of ischemic stroke.
Collapse
Affiliation(s)
- Xingwang Yong
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Shanshan Lu
- The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Yi-Cheng Hsu
- MR Collaboration, Siemens Healthcare Ltd., Shanghai, China
| | - Caixia Fu
- Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, Guangdong, China
| | - Yi Sun
- MR Collaboration, Siemens Healthcare Ltd., Shanghai, China
| | - Yi Zhang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| |
Collapse
|
15
|
DiPiero M, Rodrigues PG, Gromala A, Dean DC. Applications of advanced diffusion MRI in early brain development: a comprehensive review. Brain Struct Funct 2023; 228:367-392. [PMID: 36585970 PMCID: PMC9974794 DOI: 10.1007/s00429-022-02605-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 12/21/2022] [Indexed: 01/01/2023]
Abstract
Brain development follows a protracted developmental timeline with foundational processes of neurodevelopment occurring from the third trimester of gestation into the first decade of life. Defining structural maturational patterns of early brain development is a critical step in detecting divergent developmental trajectories associated with neurodevelopmental and psychiatric disorders that arise later in life. While considerable advancements have already been made in diffusion magnetic resonance imaging (dMRI) for pediatric research over the past three decades, the field of neurodevelopment is still in its infancy with remarkable scientific and clinical potential. This comprehensive review evaluates the application, findings, and limitations of advanced dMRI methods beyond diffusion tensor imaging, including diffusion kurtosis imaging (DKI), constrained spherical deconvolution (CSD), neurite orientation dispersion and density imaging (NODDI) and composite hindered and restricted model of diffusion (CHARMED) to quantify the rapid and dynamic changes supporting the underlying microstructural architectural foundations of the brain in early life.
Collapse
Affiliation(s)
- Marissa DiPiero
- Department of Neuroscience Training Program, University of Wisconsin-Madison, Madison, WI, 53705, USA
- Waisman Center, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | | | - Alyssa Gromala
- Waisman Center, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Douglas C Dean
- Waisman Center, University of Wisconsin-Madison, Madison, WI, 53705, USA.
- Department of Pediatrics, University of Wisconsin-Madison, Madison, WI, 53705, USA.
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, 53705, USA.
| |
Collapse
|
16
|
Taso M, Munsch F, Girard OM, Duhamel G, Alsop DC, Varma G. Fast-spin-echo versus rapid gradient-echo for 3D magnetization-prepared acquisitions: Application to inhomogeneous magnetization transfer. Magn Reson Med 2023; 89:550-564. [PMID: 36306334 PMCID: PMC10848167 DOI: 10.1002/mrm.29461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 08/23/2022] [Accepted: 08/26/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE To evaluate the benefits of fast spin echo (FSE) imaging over rapid gradient-echo (RAGE) for magnetization-prepared inhomogeneous magnetization transfer (ihMT) imaging. METHODS A 3D FSE sequence was modified to include an ihMT preparation (ihMT-FSE) with an optional CSF suppression based on an inversion-recovery (ihMT-FLAIR). After numeric simulations assessing SNR benefits of FSE and the potential impact of an additional inversion-recovery, ihMT-RAGE, ihMT-FSE, and ihMT-FLAIR sequences were compared in a group of six healthy volunteers, evaluating image quality, thermal, and physiological noise as well as quantification using an ihMT saturation (ihMTsat) approach. A preliminary exploration in the cervical spinal cord was also conducted in a group of three healthy volunteers. RESULTS Several fold improvements in thermal SNR were observed with ihMT-FSE in agreement with numerical simulations. However, we observed significantly higher physiological noise in ihMT-FSE compared to ihMT-RAGE that was mitigated in ihMT-FLAIR, which provided the best total SNR (+74% and +49% compared to ihMT-RAGE in the white and gray matter, P ≤ 0.004). IhMTsat quantification was successful in all cases with strong correlation between all sequences (r2 > 0.75). Early experiments showed potential for spinal cord imaging. CONCLUSIONS FSE generally offers higher SNR compared to gradient-echo based acquisitions for magnetization-prepared contrasts as illustrated here in the case of ihMT. However, physiological noise has a significant effect, but an inversion-recovery-based CSF suppression was shown to be efficient in mitigating effects of CSF motion.
Collapse
Affiliation(s)
- Manuel Taso
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA
| | - Fanny Munsch
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA
| | | | | | - David C. Alsop
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA
| | - Gopal Varma
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA
| |
Collapse
|
17
|
Sukstanskii AL, Yablonskiy DA. Microscopic theory of spin-spin and spin-lattice relaxation of bound protons in cellular and myelin membranes-A lateral diffusion model (LDM). Magn Reson Med 2023; 89:370-383. [PMID: 36094730 PMCID: PMC9826187 DOI: 10.1002/mrm.29430] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/26/2022] [Accepted: 08/08/2022] [Indexed: 01/12/2023]
Abstract
PURPOSE Deciphering salient features of biological tissue cellular microstructure in health and diseases is an ultimate goal of MRI. While most MRI approaches are based on studying MR properties of tissue "free" water indirectly affected by tissue microstructure, other approaches, such as magnetization transfer (MT), directly target signals from tissue-forming macromolecules. However, despite three-decades of successful applications, relationships between MT measurements and tissue microstructure remain elusive, hampering interpretation of experimental results. The goal of this paper is to develop microscopic theory connecting the structure of cellular and myelin membranes to their MR properties. THEORY AND METHODS Herein we introduce a lateral diffusion model (LDM) that explains the T2 (spin-spin) and T1 (spin-lattice) MRI relaxation properties of the macromolecular-bound protons by their dipole-dipole interaction modulated by the lateral diffusion of long lipid molecules forming cellular and myelin membranes. RESULTS LDM predicts anisotropic T1 and T2 relaxation of membrane-bound protons. Moreover, their T2 relaxation cannot be described in terms of a standard R2 = 1/T2 relaxation rate parameter, but rather by a relaxation rate function R2 (t) that depends on time t after RF excitation, having, in the main approximation, a logarithmic behavior: R2 (t) ∼ lnt. This anisotropic non-linear relaxation leads to an absorption lineshape that is different from Super-Lorentzian traditionally used in interpreting MT experiments. CONCLUSION LDM-derived analytical equations connect the membrane-bound protons T1 and T2 relaxation with dynamic distances between protons in neighboring membrane-forming lipid molecules and their lateral diffusion. This sheds new light on relationships between MT parameters and microstructure of cellular and myelin membranes.
Collapse
|
18
|
Inhomogeneous Magnetization Transfer (ihMT) imaging in the acute cuprizone mouse model of demyelination/remyelination. Neuroimage 2023; 265:119785. [PMID: 36464096 DOI: 10.1016/j.neuroimage.2022.119785] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 10/31/2022] [Accepted: 12/01/2022] [Indexed: 12/05/2022] Open
Abstract
BACKGROUND To investigate the association of ihMT (inhom signals with the demyelination and remyelination phases of the acute cuprizone mouse model in comparison with histology, and to assess the extent of tissue damage and repair from MRI data. METHODS Acute demyelination by feeding 0.2% cuprizone for five weeks, followed by a four-week remyelination period was applied on genetically modified plp-GFP mice. Animals were scanned at different time points of the demyelination and remyelination phases of the cuprizone model using a multimodal MRI protocol, including ihMT T1D-filters, MPF (Macromolecular Proton Fraction) and R1 (longitudinal relaxation rate). For histology, plp-GFP (proteolipid protein - Green Fluorescent Protein) microscopy and LFB (Luxol Fast Blue) staining were employed as references for the myelin content. Comparison of MRI with histology was performed in the medial corpus callosum (mCC) and cerebral cortex (CTX) at two brain levels whereas ROI-wise and voxel-based analyses of the MRI metrics allowed investigating in vivo the spatial extent of myelin alterations. RESULTS IhMT high-pass T1D-filters, targeted toward long T1D components, showed significant temporal variations in the mCC consistent with the effects induced by the cuprizone toxin. In addition, the corresponding signals correlated strongly and significantly with the myelin content assessed by GFP fluorescence and LFB staining over the demyelination and the remyelination phases. The signal of the band-pass T1D-filter, which isolates short T1D components, showed changes over time that were poorly correlated with histology, hence suggesting a sensitivity to pathological processes possibly not related to myelin. Although MPF was also highly correlated to histology, ihMT high-pass T1D-filters showed better capability to characterize the spatial-temporal patterns during the demyelination and remyelination phases of the acute cuprizone model (e.g., rostro-caudal gradient of demyelination in the mCC previously described in the literature). CONCLUSIONS IhMT sequences selective for long T1D components are specific and sensitive in vivo markers of demyelination and remyelination and have successfully captured the spatially heterogeneous pattern of the demyelination and remyelination mechanisms in the cuprizone model. Interestingly, differences in signal variations between the ihMT high-pass and band-pass T1D-filter, suggest a sensitivity of the ihMT sequences targeted to short T1Ds to alterations other than those of myelin. Future studies will need to further address these differences by examining more closely the origin of the short T1D components and the variation of each T1D component in pathology.
Collapse
|
19
|
Jara H, Sakai O, Farrher E, Oros-Peusquens AM, Shah NJ, Alsop DC, Keenan KE. Primary Multiparametric Quantitative Brain MRI: State-of-the-Art Relaxometric and Proton Density Mapping Techniques. Radiology 2022; 305:5-18. [PMID: 36040334 PMCID: PMC9524578 DOI: 10.1148/radiol.211519] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 05/01/2022] [Accepted: 05/24/2022] [Indexed: 11/11/2022]
Abstract
This review on brain multiparametric quantitative MRI (MP-qMRI) focuses on the primary subset of quantitative MRI (qMRI) parameters that represent the mobile ("free") and bound ("motion-restricted") proton pools. Such primary parameters are the proton densities, relaxation times, and magnetization transfer parameters. Diffusion qMRI is also included because of its wide implementation in complete clinical MP-qMRI application. MP-qMRI advances were reviewed over the past 2 decades, with substantial progress observed toward accelerating image acquisition and increasing mapping accuracy. Areas that need further investigation and refinement are identified as follows: (a) the biologic underpinnings of qMRI parameter values and their changes with age and/or disease and (b) the theoretical limitations implicitly built into most qMRI mapping algorithms that do not distinguish between the different spatial scales of voxels versus spin packets, the central physical object of the Bloch theory. With rapidly improving image processing techniques and continuous advances in computer hardware, MP-qMRI has the potential for implementation in a wide range of clinical applications. Currently, three emerging MP-qMRI applications are synthetic MRI, macrostructural qMRI, and microstructural tissue modeling.
Collapse
Affiliation(s)
- Hernán Jara
- From the Department of Radiology, Boston University, 670 Albany St,
Boston, Mass 02118 (H.J., O.S.); Institute of Neuroscience and Medicine-4,
Forschungszentrum Jülich, Jülich, Germany (E.F., A.M.O.P.,
N.J.S.); Department of Radiology, Beth Israel Deaconess Medical Center, Harvard
Medical School, Boston, Mass (D.C.A.); and Physical Measurement Laboratory,
National Institute of Standards and Technology, Boulder, Colo (K.E.K.)
| | - Osamu Sakai
- From the Department of Radiology, Boston University, 670 Albany St,
Boston, Mass 02118 (H.J., O.S.); Institute of Neuroscience and Medicine-4,
Forschungszentrum Jülich, Jülich, Germany (E.F., A.M.O.P.,
N.J.S.); Department of Radiology, Beth Israel Deaconess Medical Center, Harvard
Medical School, Boston, Mass (D.C.A.); and Physical Measurement Laboratory,
National Institute of Standards and Technology, Boulder, Colo (K.E.K.)
| | - Ezequiel Farrher
- From the Department of Radiology, Boston University, 670 Albany St,
Boston, Mass 02118 (H.J., O.S.); Institute of Neuroscience and Medicine-4,
Forschungszentrum Jülich, Jülich, Germany (E.F., A.M.O.P.,
N.J.S.); Department of Radiology, Beth Israel Deaconess Medical Center, Harvard
Medical School, Boston, Mass (D.C.A.); and Physical Measurement Laboratory,
National Institute of Standards and Technology, Boulder, Colo (K.E.K.)
| | - Ana-Maria Oros-Peusquens
- From the Department of Radiology, Boston University, 670 Albany St,
Boston, Mass 02118 (H.J., O.S.); Institute of Neuroscience and Medicine-4,
Forschungszentrum Jülich, Jülich, Germany (E.F., A.M.O.P.,
N.J.S.); Department of Radiology, Beth Israel Deaconess Medical Center, Harvard
Medical School, Boston, Mass (D.C.A.); and Physical Measurement Laboratory,
National Institute of Standards and Technology, Boulder, Colo (K.E.K.)
| | - N. Jon Shah
- From the Department of Radiology, Boston University, 670 Albany St,
Boston, Mass 02118 (H.J., O.S.); Institute of Neuroscience and Medicine-4,
Forschungszentrum Jülich, Jülich, Germany (E.F., A.M.O.P.,
N.J.S.); Department of Radiology, Beth Israel Deaconess Medical Center, Harvard
Medical School, Boston, Mass (D.C.A.); and Physical Measurement Laboratory,
National Institute of Standards and Technology, Boulder, Colo (K.E.K.)
| | - David C. Alsop
- From the Department of Radiology, Boston University, 670 Albany St,
Boston, Mass 02118 (H.J., O.S.); Institute of Neuroscience and Medicine-4,
Forschungszentrum Jülich, Jülich, Germany (E.F., A.M.O.P.,
N.J.S.); Department of Radiology, Beth Israel Deaconess Medical Center, Harvard
Medical School, Boston, Mass (D.C.A.); and Physical Measurement Laboratory,
National Institute of Standards and Technology, Boulder, Colo (K.E.K.)
| | - Kathryn E. Keenan
- From the Department of Radiology, Boston University, 670 Albany St,
Boston, Mass 02118 (H.J., O.S.); Institute of Neuroscience and Medicine-4,
Forschungszentrum Jülich, Jülich, Germany (E.F., A.M.O.P.,
N.J.S.); Department of Radiology, Beth Israel Deaconess Medical Center, Harvard
Medical School, Boston, Mass (D.C.A.); and Physical Measurement Laboratory,
National Institute of Standards and Technology, Boulder, Colo (K.E.K.)
| |
Collapse
|
20
|
Role of Demyelination in the Persistence of Neurological and Mental Impairments after COVID-19. Int J Mol Sci 2022; 23:ijms231911291. [PMID: 36232592 PMCID: PMC9569975 DOI: 10.3390/ijms231911291] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/16/2022] [Accepted: 09/21/2022] [Indexed: 11/16/2022] Open
Abstract
Long-term neurological and mental complications of COVID-19, the so-called post-COVID syndrome or long COVID, affect the quality of life. The most persistent manifestations of long COVID include fatigue, anosmia/hyposmia, insomnia, depression/anxiety, and memory/attention deficits. The physiological basis of neurological and psychiatric disorders is still poorly understood. This review summarizes the current knowledge of neurological sequelae in post-COVID patients and discusses brain demyelination as a possible mechanism of these complications with a focus on neuroimaging findings. Numerous reviews, experimental and theoretical studies consider brain demyelination as one of the mechanisms of the central neural system impairment. Several factors might cause demyelination, such as inflammation, direct effect of the virus on oligodendrocytes, and cerebrovascular disorders, inducing myelin damage. There is a contradiction between the solid fundamental basis underlying demyelination as the mechanism of the neurological injuries and relatively little published clinical evidence related to demyelination in COVID-19 patients. The reason for this probably lies in the fact that most clinical studies used conventional MRI techniques, which can detect only large, clearly visible demyelinating lesions. A very limited number of studies use specific methods for myelin quantification detected changes in the white matter tracts 3 and 10 months after the acute phase of COVID-19. Future research applying quantitative MRI assessment of myelin in combination with neurological and psychological studies will help in understanding the mechanisms of post-COVID complications associated with demyelination.
Collapse
|
21
|
Morris SR, Frederick R, MacKay AL, Laule C, Michal CA. Orientation dependence of inhomogeneous magnetization transfer and dipolar order relaxation rate in phospholipid bilayers. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 338:107205. [PMID: 35390716 DOI: 10.1016/j.jmr.2022.107205] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 03/02/2022] [Accepted: 03/21/2022] [Indexed: 06/14/2023]
Abstract
Inhomogeneous magnetization transfer (ihMT) is a novel MRI technique used to measure white matter myelination in the brain and spinal cord. In the brain, ihMT has a strong orientation dependence which is likely to arise from the anisotropy of dipolar couplings between protons on oriented lipids in the myelin bilayers. We measured the orientation dependence of the second moment (M2) of the lineshape, dipolar order relaxation rate (R1D), and ihMT ratio (ihMTR) in an oriented phospholipid bilayer at 9.4 T. We found a strong orientation dependence in all three parameters. ihMTR and R1D were maximized when the bilayers were aligned perpendicular to B0 and minimized near the magic angle (∼54.7°). M2 followed an orientation dependence given by the second Legendre polynomial squared as predicted by the form of the secular dipolar Hamiltonian. These results were used to calculate the orientation dependence of R1D and ihMTR in a diffusionless myelin sheath model, which showed ihMTR was maximised for fibers perpendicular to B0 and minimised at 45°, similar to ex-vivo spinal cord with a larger prepulse frequency offset, but in contrast to in vivo brain findings. Adding fiber dispersion to this model smoothed the orientation dependence curve as expected. Our results suggest the importance of the effects of lipid diffusion and prepulse offset frequency on ihMTR.
Collapse
Affiliation(s)
- Sarah R Morris
- International Collaboration on Repair Discoveries (ICORD), University of British Columbia, Canada; Dept. of Radiology, University of British Columbia, Canada; Dept. of Physics & Astronomy, University of British Columbia, Canada
| | - Rebecca Frederick
- Dept. of Physics & Astronomy, University of British Columbia, Canada
| | - Alex L MacKay
- Dept. of Radiology, University of British Columbia, Canada; Dept. of Physics & Astronomy, University of British Columbia, Canada; UBC MRI Research Centre, University of British Columbia, Canada
| | - Cornelia Laule
- International Collaboration on Repair Discoveries (ICORD), University of British Columbia, Canada; Dept. of Radiology, University of British Columbia, Canada; Dept. of Physics & Astronomy, University of British Columbia, Canada; Dept. of Pathology and Laboratory Medicine, University of British Columbia, Canada
| | - Carl A Michal
- Dept. of Physics & Astronomy, University of British Columbia, Canada
| |
Collapse
|
22
|
York EN, Thrippleton MJ, Meijboom R, Hunt DPJ, Waldman AD. Quantitative magnetization transfer imaging in relapsing-remitting multiple sclerosis: a systematic review and meta-analysis. Brain Commun 2022; 4:fcac088. [PMID: 35652121 PMCID: PMC9149789 DOI: 10.1093/braincomms/fcac088] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 12/17/2021] [Accepted: 03/31/2022] [Indexed: 11/28/2022] Open
Abstract
Myelin-sensitive MRI such as magnetization transfer imaging has been widely used in multiple sclerosis. The influence of methodology and differences in disease subtype on imaging findings is, however, not well established. Here, we systematically review magnetization transfer brain imaging findings in relapsing-remitting multiple sclerosis. We examine how methodological differences, disease effects and their interaction influence magnetization transfer imaging measures. Articles published before 06/01/2021 were retrieved from online databases (PubMed, EMBASE and Web of Science) with search terms including 'magnetization transfer' and 'brain' for systematic review, according to a pre-defined protocol. Only studies that used human in vivo quantitative magnetization transfer imaging in adults with relapsing-remitting multiple sclerosis (with or without healthy controls) were included. Additional data from relapsing-remitting multiple sclerosis subjects acquired in other studies comprising mixed disease subtypes were included in meta-analyses. Data including sample size, MRI acquisition protocol parameters, treatments and clinical findings were extracted and qualitatively synthesized. Where possible, effect sizes were calculated for meta-analyses to determine magnetization transfer (i) differences between patients and healthy controls; (ii) longitudinal change and (iii) relationships with clinical disability in relapsing-remitting multiple sclerosis. Eighty-six studies met inclusion criteria. MRI acquisition parameters varied widely, and were also underreported. The majority of studies examined the magnetization transfer ratio in white matter, but magnetization transfer metrics, brain regions examined and results were heterogeneous. The analysis demonstrated a risk of bias due to selective reporting and small sample sizes. The pooled random-effects meta-analysis across all brain compartments revealed magnetization transfer ratio was 1.17 per cent units (95% CI -1.42 to -0.91) lower in relapsing-remitting multiple sclerosis than healthy controls (z-value: -8.99, P < 0.001, 46 studies). Linear mixed-model analysis did not show a significant longitudinal change in magnetization transfer ratio across all brain regions [β = 0.12 (-0.56 to 0.80), t-value = 0.35, P = 0.724, 14 studies] or normal-appearing white matter alone [β = 0.037 (-0.14 to 0.22), t-value = 0.41, P = 0.68, eight studies]. There was a significant negative association between the magnetization transfer ratio and clinical disability, as assessed by the Expanded Disability Status Scale [r = -0.32 (95% CI -0.46 to -0.17); z-value = -4.33, P < 0.001, 13 studies]. Evidence suggests that magnetization transfer imaging metrics are sensitive to pathological brain changes in relapsing-remitting multiple sclerosis, although effect sizes were small in comparison to inter-study variability. Recommendations include: better harmonized magnetization transfer acquisition protocols with detailed methodological reporting standards; larger, well-phenotyped cohorts, including healthy controls; and, further exploration of techniques such as magnetization transfer saturation or inhomogeneous magnetization transfer ratio.
Collapse
Affiliation(s)
- Elizabeth N. York
- Centre for Clinical Brain Sciences, University of
Edinburgh, Edinburgh, UK
| | | | - Rozanna Meijboom
- Centre for Clinical Brain Sciences, University of
Edinburgh, Edinburgh, UK
| | - David P. J. Hunt
- Centre for Clinical Brain Sciences, University of
Edinburgh, Edinburgh, UK
- UK Dementia Research Institute, University of
Edinburgh, Edinburgh, UK
- Anne Rowling Regenerative Neurology Clinic,
University of Edinburgh, Edinburgh, UK
| | - Adam D. Waldman
- Centre for Clinical Brain Sciences, University of
Edinburgh, Edinburgh, UK
- UK Dementia Research Institute, University of
Edinburgh, Edinburgh, UK
| |
Collapse
|
23
|
Lee CH, Walczak P, Zhang J. Inhomogeneous magnetization transfer MRI of white matter structures in the hypomyelinated shiverer mouse brain. Magn Reson Med 2022; 88:332-340. [PMID: 35344613 DOI: 10.1002/mrm.29207] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Revised: 12/31/2021] [Accepted: 02/04/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE Inhomogeneous magnetization transfer (ihMT) MRI is uniquely sensitive to myelin with lipids as a primary source of its contrast. In this study, we investigated whether ihMT can detect white matter structures in the hypomyelinated shiverer mouse brain, a model of dysmyelination. METHODS Conventional MT and ihMT images were acquired from ex vivo Rag2-/- control and shiverer mouse brains at 7T using previously reported optimized saturation parameters. RESULTS ihMT ratio (ihMTR) maps revealed hypomyelinated corpus callosum in the shiverer mouse brain, whereas conventional MT ratio (MTR) maps showed no clear contrast. The ihMTR values of the corpus callosum in the shiverer mice were reduced by approximately 40% compared to controls, but remained significantly higher than the ihMTR values of the cortex. CONCLUSION The finding further confirms ihMT's high myelin specificity and suggests its use as a marker to detect early myelination or myelin repair.
Collapse
Affiliation(s)
- Choong Heon Lee
- Center for Biomedical Imaging, Department of Radiology, New York University Langone School of Medicine, New York, NY, USA
| | - Piotr Walczak
- Department of Radiology, University of Maryland, Baltimore, MD, USA
| | - Jiangyang Zhang
- Center for Biomedical Imaging, Department of Radiology, New York University Langone School of Medicine, New York, NY, USA
| |
Collapse
|
24
|
Hertanu A, Soustelle L, Le Troter A, Buron J, Le Priellec J, Carvalho VND, Cayre M, Durbec P, Varma G, Alsop DC, Girard OM, Duhamel G. T 1D -weighted ihMT imaging - Part I. Isolation of long- and short-T 1D components by T 1D -filtering. Magn Reson Med 2022; 87:2313-2328. [PMID: 35037302 DOI: 10.1002/mrm.29139] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 10/29/2021] [Accepted: 12/12/2021] [Indexed: 01/15/2023]
Abstract
PURPOSE To identify T1D -filtering methods, which can specifically isolate various ranges of T1D components as they may be sensitive to different microstructural properties. METHODS Modified Bloch-Provotorov equations describing a bi-T1D component biophysical model were used to simulate the inhomogeneous magnetization transfer (ihMT) signal from ihMTRAGE sequences at high RF power and low duty-cycle with different switching time values for the dual saturation experiment: Δt = 0.0, 0.8, 1.6, and 3.2 ms. Simulations were compared with experimental signals on the brain gray and white matter tissues of healthy mice at 7T. RESULTS The lengthening of Δt created ihMT high-pass T1D -filters, which efficiently eliminated the signal from T1D components shorter than 1 ms, while partially attenuating that of longer components (≥ 1 ms). Subtraction of ihMTR images obtained with Δt = 0.0 ms and Δt = 0.8 ms generated a new ihMT band-pass T1D -filter isolating short-T1D components in the 100-µs to 1-ms range. Simulated ihMTR values in central nervous system tissues were confirmed experimentally. CONCLUSION Long- and short-T1D components were successfully isolated with high RF power and low duty-cycle ihMT filters in the healthy mouse brain. Future studies should investigate the various T1D -range microstructural correlations in in vivo tissues.
Collapse
Affiliation(s)
- Andreea Hertanu
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Lucas Soustelle
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Arnaud Le Troter
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Julie Buron
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France.,Aix Marseille Univ, CNRS, IBDM, Marseille, France
| | | | - Victor N D Carvalho
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France.,Aix Marseille Univ, CNRS, ICR, Marseille, France
| | - Myriam Cayre
- Aix Marseille Univ, CNRS, IBDM, Marseille, France
| | | | - Gopal Varma
- Division of MR Research, Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - David C Alsop
- Division of MR Research, Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Olivier M Girard
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Guillaume Duhamel
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| |
Collapse
|
25
|
Hertanu A, Soustelle L, Buron J, Le Priellec J, Cayre M, Le Troter A, Varma G, Alsop DC, Durbec P, Girard OM, Duhamel G. T 1D -weighted ihMT imaging - Part II. Investigating the long- and short-T 1D components correlation with myelin content. Comparison with R 1 and the macromolecular proton fraction. Magn Reson Med 2022; 87:2329-2346. [PMID: 35001427 DOI: 10.1002/mrm.29140] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 10/29/2021] [Accepted: 12/12/2021] [Indexed: 12/22/2022]
Abstract
PURPOSE To investigate the long- and short-T1D components correlation with myelin content using inhomogeneous magnetization transfer (ihMT) high-pass and band-pass T1D -filters and to compare ihMT, R1 , and the macromolecular proton fraction (MPF) for myelin specific imaging. METHODS The 3D ihMT rapid gradient echo (ihMTRAGE) sequences with increasing switching times (Δt) were used to derive ihMT high-pass T1D -filters with increasing T1D cutoff values and an ihMT band-pass T1D -filter for components in the 100 µs to 1 ms range. 3D spoiled gradient echo quantitative MT (SPGR-qMT) protocols were used to derive R1 and MPF maps. The specificity of R1 , MPF, and ihMT T1D -filters was evaluated by comparison with two histological reference techniques for myelin imaging. RESULTS The higher contribution of long-T1D s as compared to the short components as Δt got longer led to an increase in the specificity to myelination. In contrast, focusing on the signal originating from a narrow range of short-T1D s (< 1 ms) as isolated by the band-pass T1D -filter led to lower specificity. In addition, the significantly lower r2 correlation coefficient of the band-pass T1D -filter suggests that the origin of short-T1D components is mostly associated with non-myelin protons. Also, the important contribution of short-T1D s to the estimated MPF, explains its low specificity to myelination as compared to the ihMT high-pass T1D -filters. CONCLUSION Long-T1D components imaging by means of ihMT high-pass T1D -filters is proposed as an MRI biomarker for myelin content. Future studies should enable the investigation of the sensitivity of ihMT T1D -filters for demyelinating processes.
Collapse
Affiliation(s)
- Andreea Hertanu
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Lucas Soustelle
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Julie Buron
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France.,Aix Marseille Univ, CNRS, IBDM, Marseille, France
| | | | - Myriam Cayre
- Aix Marseille Univ, CNRS, IBDM, Marseille, France
| | - Arnaud Le Troter
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Gopal Varma
- Division of MR Research, Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - David C Alsop
- Division of MR Research, Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | | | - Olivier M Girard
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Guillaume Duhamel
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| |
Collapse
|
26
|
Forodighasemabadi A, Baucher G, Soustelle L, Troalen T, Girard OM, Guye M, Grisoli JB, Ranjeva JP, Duhamel G, Callot V. Spinal cord and brain tissue impairments as long-term effects of rugby practice? An exploratory study based on T1 and ihMTsat measures. NEUROIMAGE: CLINICAL 2022; 35:103124. [PMID: 35905667 PMCID: PMC9421542 DOI: 10.1016/j.nicl.2022.103124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 07/14/2022] [Accepted: 07/20/2022] [Indexed: 12/03/2022] Open
Abstract
Diffuse degeneration of spinal cord (higher T1) is observed in retired rugby players. Demyelination of brain WM tracts (higher T1 / lower ihMTsat values) is present in rugby players. Early aging in both brain and spinal cord tissues may be linked to the rugby practice. The aforementioned effects may suggest cumulative effects of long-term impacts on the tissues.
Rugby players are subject to multiple impacts to their head and neck that could have adverse neurological effects and put them at increased risk of neurodegeneration. Previous studies demonstrated altered default mode network and diffusion metrics on brain, as well as more foraminal stenosis, disc protrusion and neck pain among players of contact sports as compared to healthy controls. However, the long-term effects of practice and repetitive impacts on brain and cervical spinal cord (cSC) of the rugby players have never been systematically investigated. In this study, 15 retired professional and amateur rugby players (R) and 15 age-matched healthy controls (HC) (all males; mean age R: 46.8 ± 7.6; and HC: 48.6 ± 9.5) were recruited both to investigate cord impairments and further characterize brain structure damage. Medical questionnaires including modified Japanese Orthopedic Association scale (mJOA) and Neck Disability Index (NDI) were filled by all participants. A 3 T multi-parametric MR protocol including conventional qualitative techniques such as T1-, T2-, and T2*-weighted sequences, as well as state-of-the art quantitative techniques including MP2RAGE T1 mapping and 3D ihMTRAGE, was used on both brain and cSC. Normalized brain WM and GM volumes, spine Overall Stenosis Score, cord cross-sectional area and regional T1 and ihMT metrics were derived from these acquisitions. Rugby players showed significantly higher NDI scores, as well as a faster decline of normalized brain GM volume with age as compared to HC. Moreover, higher T1 values on cSC suggestive of structural degeneration, together with higher T1 and lower ihMTsat on brain WM suggestive of demyelination, were observed in retired rugby players as compared to age-matched controls, which may suggest cumulative effects of long-term impacts on the tissues. Metrics also suggest early aging and different aging processes on brain tissue in the players. These preliminary observations provide new insights in the domain, which should now be further investigated on larger cohorts and multicentric longitudinal studies, and further correlated to the likelihood of neurodegenerative diseases and risk factors.
Collapse
|
27
|
West DJ, Cruz G, Teixeira RPAG, Schneider T, Tournier JD, Hajnal JV, Prieto C, Malik SJ. An MR fingerprinting approach for quantitative inhomogeneous magnetization transfer imaging. Magn Reson Med 2022; 87:220-235. [PMID: 34418151 PMCID: PMC7614010 DOI: 10.1002/mrm.28984] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 07/15/2021] [Accepted: 08/05/2021] [Indexed: 01/07/2023]
Abstract
PURPOSE Magnetization transfer (MT) and inhomogeneous MT (ihMT) contrasts are used in MRI to provide information about macromolecular tissue content. In particular, MT is sensitive to macromolecules, and ihMT appears to be specific to myelinated tissue. This study proposes a technique to characterize MT and ihMT properties from a single acquisition, producing both semiquantitative contrast ratios and quantitative parameter maps. THEORY AND METHODS Building on previous work that uses multiband RF pulses to efficiently generate ihMT contrast, we propose a cyclic steady-state approach that cycles between multiband and single-band pulses to boost the achieved contrast. Resultant time-variable signals are reminiscent of an MR fingerprinting acquisition, except that the signal fluctuations are entirely mediated by MT effects. A dictionary-based low-rank inversion method is used to reconstruct the resulting images and to produce both semiquantitative MT ratio and ihMT ratio maps, as well as quantitative parameter estimates corresponding to an ihMT tissue model. RESULTS Phantom and in vivo brain data acquired at 1.5 Tesla demonstrate the expected contrast trends, with ihMT ratio maps showing contrast more specific to white matter, as has been reported by others. Quantitative estimation of semisolid fraction and dipolar T1 was also possible and yielded measurements consistent with literature values in the brain. CONCLUSION By cycling between multiband and single-band pulses, an entirely MT-mediated fingerprinting method was demonstrated. This proof-of-concept approach can be used to generate semiquantitative maps and quantitatively estimate some macromolecular-specific tissue parameters.
Collapse
Affiliation(s)
- Daniel J. West
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom
| | - Gastao Cruz
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom
| | - Rui P. A. G. Teixeira
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom
| | | | - Jacques-Donald Tournier
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom
| | - Joseph V. Hajnal
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom
| | - Claudia Prieto
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom
| | - Shaihan J. Malik
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King’s College London, St. Thomas’ Hospital, London, United Kingdom
| |
Collapse
|
28
|
Soustelle L, Troalen T, Hertanu A, Mchinda S, Ranjeva JP, Guye M, Varma G, Alsop DC, Duhamel G, Girard OM. A strategy to reduce the sensitivity of inhomogeneous magnetization transfer (ihMT) imaging to radiofrequency transmit field variations at 3 T. Magn Reson Med 2021; 87:1346-1359. [PMID: 34779020 DOI: 10.1002/mrm.29055] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/17/2021] [Accepted: 10/05/2021] [Indexed: 02/05/2023]
Abstract
PURPOSE To minimize the sensitivity of inhomogeneous magnetization transfer gradient-echo (ihMT-GRE) imaging to radiofrequency (RF) transmit field ( B 1 + ) inhomogeneities at 3 T. METHODS The ihMT-GRE sequence was optimized by varying the concentration of the RF saturation energy over time, obtained by increasing the saturation pulse power while extending the sequence repetition time (TR). Different protocols were tested using numerical simulations and human in vivo experiments in the brain white matter (WM) of healthy subjects at 3 T. The sensitivity of the ihMT ratio (ihMTR) to B 1 + variations was investigated by comparing measurements obtained at nominal transmitter adjustments and following a 20% global B 1 + drop. The resulting relative variations (δihMTR ) were evaluated voxelwise as a function of the local B 1 + distribution. The reproducibility of the protocol providing minimal B 1 + bias was assessed in a test-retest experiment. RESULTS In line with simulations, ihMT-GRE experiments conducted at high concentration of the RF energy over time demonstrated strong reduction of the B 1 + inhomogeneity effects in the human WM. Under the optimal conditions of 350-ms TR and 3-µT root mean square (RMS) saturation power, 73% of all WM voxels presented δihMTR below 10%. Reproducibility analysis yielded a close-to-zero systematic bias (ΔihMTR = -0.081%) and a high correlation (ρ² = 0.977) between test and retest experiments. CONCLUSION Concentrating RF saturation energy in ihMT-GRE sequences mitigates the sensitivity of the ihMTR to B 1 + variations and allows for clinical-ready ihMT imaging at 3 T. This feature is of particular interest for high and ultra-high field applications.
Collapse
Affiliation(s)
- Lucas Soustelle
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | | | - Andreea Hertanu
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Samira Mchinda
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Jean-Philippe Ranjeva
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Maxime Guye
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Gopal Varma
- Division of MR Research, Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - David C Alsop
- Division of MR Research, Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Guillaume Duhamel
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| | - Olivier M Girard
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France
| |
Collapse
|
29
|
Huang J, Xu J, Lai JHC, Chen Z, Lee CY, Mak HKF, Chan KH, Chan KWY. Relayed nuclear Overhauser effect weighted (rNOEw) imaging identifies multiple sclerosis. NEUROIMAGE-CLINICAL 2021; 32:102867. [PMID: 34751151 PMCID: PMC8569719 DOI: 10.1016/j.nicl.2021.102867] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 10/12/2021] [Accepted: 10/25/2021] [Indexed: 10/25/2022]
Abstract
Multiple sclerosis (MS) is an autoimmune disease of the central nervous system in which the immune system attacks the myelin and axons, consequently leading to demyelination and axonal injury. Magnetic resonance imaging (MRI) plays a pivotal role in the diagnosis of MS, and currently various types of MRI techniques have been used to detect the pathology of MS based on unique mechanisms. In this study, we applied the relayed nuclear Overhauser effect weighted (rNOEw) imaging to study human MS at clinical 3T. Three groups of subjects, including 20 normal control (NC) subjects, 14 neuromyelitis optica spectrum disorders (NMOSD) patients and 21 MS patients, were examined at a clinical 3T MRI scanner. Whole-brain rNOEw images of each subject were obtained by acquiring a control and a labeled image within four minutes. Significantly lower brain rNOEw contrast was detected in MS group compared to NC (P = 0.008) and NMOSD (P = 0.014) groups, while no significant difference was found between NC and NMOSD groups (P = 0.939). The lower rNOEw contrast of MS group compared to NC/NMOSD group was significant in white matter (P = 0.041/0.021), gray matter (P = 0.004/0.020) and brain parenchyma (P = 0.015/0.021). Moreover, MS lesions showed higher number and larger size but lower rNOEw contrast than NMOSD lesions (P = 0.002). Our proposed rNOEw imaging scheme has potential to serve as a new method for assisting MS diagnosis. Importantly, it may be used to identify MS from NMOSD.
Collapse
Affiliation(s)
- Jianpan Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA; Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Joseph H C Lai
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zilin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Chi Yan Lee
- Department of Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong Kong, China
| | - Henry K F Mak
- Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong Kong, China
| | - Koon Ho Chan
- Department of Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong Kong, China.
| | - Kannie W Y Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; City University of Hong Kong Shenzhen Research Institute, Shenzhen, China; Hong Kong Centre for Cerebro-Cardiovascular Health Engineering, Hong Kong, China.
| |
Collapse
|
30
|
Prevost VH, Yung A, Morris SR, Vavasour IM, Samadi-Bahrami Z, Moore GRW, Laule C, Mackay A, Kozlowski P. Temperature dependence and histological correlation of inhomogeneous magnetization transfer and myelin water imaging in ex vivo brain. Neuroimage 2021; 236:118046. [PMID: 33848620 DOI: 10.1016/j.neuroimage.2021.118046] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 04/02/2021] [Accepted: 04/02/2021] [Indexed: 11/26/2022] Open
Abstract
PURPOSE The promise of inhomogeneous magnetization transfer (ihMT) as a new myelin imaging method was studied in ex vivo human brain tissue and in relation to myelin water fraction (MWF). The temperature dependence of both methods was characterized, as well as their correspondence with a histological measure of myelin content. Unfiltered and filtered ihMT protocols were studied by adjusting the saturation scheme to preserve or attenuate signal from tissue with short dipolar relaxation time T1D. METHODS ihMT ratio (ihMTR) and MWF maps were acquired at 7 T from formalin-fixed human brain samples at 22.5 °C, 30 °C and 37 °C. The impact of temperature on unfiltered ihMTR, filtered ihMTR and MWF was investigated and compared to myelin basic protein staining. RESULTS Unfiltered ihMTR exhibited no temperature dependence, whereas filtered ihMTR increased with increasing temperature. MWF decreased at higher temperature, with an increasing prevalence of areas where the myelin water signal was unreliably determined, likely related to a reduction in T2 peak separability at higher temperatures ex vivo. MWF and ihMTR showed similar per-sample correlation with myelin staining at room temperature. At 37 °C, filtered ihMTR was more strongly correlated with myelin staining and had increased dynamic range compared to unfiltered ihMTR. CONCLUSIONS Given the temperature dependence of filtered ihMT, increased dynamic range, and strong myelin specificity that persists at higher temperatures, we recommend carefully controlled temperatures close to 37 °C for filtered ihMT acquisitions. Unfiltered ihMT may also be useful, due to its independence from temperature, higher amplitude values, and sensitivity to short T1D components. Ex vivo myelin water imaging should be performed at room temperature, to avoid fitting issues found at higher temperatures.
Collapse
Affiliation(s)
- Valentin H Prevost
- University of British Columbia MRI Research Centre, 2221 Wesbrook Mall, M10 Purdy Pavilion, Vancouver, BC V6T 2B5, Canada.
| | - Andrew Yung
- University of British Columbia MRI Research Centre, 2221 Wesbrook Mall, M10 Purdy Pavilion, Vancouver, BC V6T 2B5, Canada.
| | - Sarah R Morris
- Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC V6T 1Z1, Canada; Radiology, University of British Columbia, 2775 Laurel Street, 11th Floor, Vancouver, BC V5Z 1M9, Canada; ICORD (International Collaboration on Repair Discoveries), 818 W. 10th Ave., Vancouver, BC V5Z 1M9, Canada.
| | - Irene M Vavasour
- Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC V6T 1Z1, Canada.
| | - Zahra Samadi-Bahrami
- Pathology & Laboratory Medicine, University of British Columbia, G105-2211 Wesbrook Mall, Vancouver, BC V6T 2B5, Canada.
| | - G R Wayne Moore
- Pathology & Laboratory Medicine, University of British Columbia, G105-2211 Wesbrook Mall, Vancouver, BC V6T 2B5, Canada.
| | - Cornelia Laule
- Radiology, University of British Columbia, 2775 Laurel Street, 11th Floor, Vancouver, BC V5Z 1M9, Canada; Pathology & Laboratory Medicine, University of British Columbia, G105-2211 Wesbrook Mall, Vancouver, BC V6T 2B5, Canada; Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC V6T 1Z1, Canada; ICORD (International Collaboration on Repair Discoveries), 818 W. 10th Ave., Vancouver, BC V5Z 1M9, Canada.
| | - Alex Mackay
- University of British Columbia MRI Research Centre, 2221 Wesbrook Mall, M10 Purdy Pavilion, Vancouver, BC V6T 2B5, Canada; Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC V6T 1Z1, Canada; Radiology, University of British Columbia, 2775 Laurel Street, 11th Floor, Vancouver, BC V5Z 1M9, Canada.
| | - Piotr Kozlowski
- University of British Columbia MRI Research Centre, 2221 Wesbrook Mall, M10 Purdy Pavilion, Vancouver, BC V6T 2B5, Canada; Radiology, University of British Columbia, 2775 Laurel Street, 11th Floor, Vancouver, BC V5Z 1M9, Canada; ICORD (International Collaboration on Repair Discoveries), 818 W. 10th Ave., Vancouver, BC V5Z 1M9, Canada.
| |
Collapse
|
31
|
Hou G, Lai W, Jiang W, Liu X, Qian L, Zhang Y, Zhou Z. Myelin deficits in patients with recurrent major depressive disorder: An inhomogeneous magnetization transfer study. Neurosci Lett 2021; 750:135768. [PMID: 33636288 DOI: 10.1016/j.neulet.2021.135768] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 01/30/2021] [Accepted: 02/19/2021] [Indexed: 02/08/2023]
Abstract
PURPOSES The recently developed myelin imaging method, inhomogeneous magnetization transfer (ihMT), is a surrogate measure of myelin content. The goal of the current study was to investigate alterations in myelin integrity in patients with recurrent major depressive disorder (rMDD). METHODS Fifty-two patients with rMDD (36 female and 16 male) and 42 healthy controls (HC, 29 female and 13 male) were included. Two ihMT indices, quantitative ihMT (qihMT) and quantitative MT (qMT), were estimated from the ihMT data. A 50 white matter atlas was used to extract the regional quantitative values for each subject. The differences in qihMT and qMT values between the rMDD and HC groups were compared by a general linear model. Pearson correlation analyses were conducted to investigate associations between the significantly altered ihMT indices and clinical measures (Hamilton Depression Rating Scale scores and disease duration) in rMDD group. RESULTS The rMDD group showed significantly lower qihMT values in the fornix, left anterior limb of internal capsule, and left sagittal stratum, and lower qMT values in the fornix and left anterior limb of internal capsule than those of the HC group (p < 0.05, false discovery rate corrected). Both the qihMT and qMT values in the fornix of patients with rMDD were negatively correlated with disease duration (qihMT: r = -0.478, p < 0.001, Bonferroni corrected; qMT: r = -0.433, p = 0.001, Bonferroni corrected). CONCLUSION Our findings suggested that rMDD is associated with myelin impairment in the fornix, left anterior limb of internal capsule, and left sagittal stratum. In addition, this disruption of myelin integrity in the fornix could be cumulative as the disease progresses.
Collapse
Affiliation(s)
- Gangqiang Hou
- Department of Radiology, Shenzhen Kangning Hospital, Shenzhen Mental Health Center, Shenzhen, 518020, China
| | - Wentao Lai
- Department of Radiology, Shenzhen Kangning Hospital, Shenzhen Mental Health Center, Shenzhen, 518020, China
| | - Wentao Jiang
- Department of Radiology, Shenzhen Kangning Hospital, Shenzhen Mental Health Center, Shenzhen, 518020, China
| | - Xia Liu
- Department of Radiology, Shenzhen Kangning Hospital, Shenzhen Mental Health Center, Shenzhen, 518020, China
| | - Long Qian
- MR Research, GE Healthcare, Beijing, 100176, China
| | - Yingli Zhang
- Department of Psychology, Shenzhen Kangning Hospital, Shenzhen Mental Health Center, Shenzhen, 518020, China.
| | - Zhifeng Zhou
- Department of Radiology, Shenzhen Kangning Hospital, Shenzhen Mental Health Center, Shenzhen, 518020, China.
| |
Collapse
|
32
|
van der Weijden CWJ, García DV, Borra RJH, Thurner P, Meilof JF, van Laar PJ, Dierckx RAJO, Gutmann IW, de Vries EFJ. Myelin quantification with MRI: A systematic review of accuracy and reproducibility. Neuroimage 2020; 226:117561. [PMID: 33189927 DOI: 10.1016/j.neuroimage.2020.117561] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 10/27/2020] [Accepted: 11/07/2020] [Indexed: 12/29/2022] Open
Abstract
OBJECTIVES Currently, multiple sclerosis is treated with anti-inflammatory therapies, but these treatments lack efficacy in progressive disease. New treatment strategies aim to repair myelin damage and efficacy evaluation of such new therapies would benefit from validated myelin imaging techniques. Several MRI methods for quantification of myelin density are available now. This systematic review aims to analyse the performance of these MRI methods. METHODS Studies comparing myelin quantification by MRI with histology, the current gold standard, or assessing reproducibility were retrieved from PubMed/MEDLINE and Embase (until December 2019). Included studies assessed both myelin histology and MRI quantitatively. Correlation or variance measurements were extracted from the studies. Non-parametric tests were used to analyse differences in study methodologies. RESULTS The search yielded 1348 unique articles. Twenty-two animal studies and 13 human studies correlated myelin MRI with histology. Eighteen clinical studies analysed the reproducibility. Overall bias risk was low or unclear. All MRI methods performed comparably, with a mean correlation between MRI and histology of R2=0.54 (SD=0.30) for animal studies, and R2=0.54 (SD=0.18) for human studies. Reproducibility for the MRI methods was good (ICC=0.75-0.93, R2=0.90-0.98, COV=1.3-27%), except for MTR (ICC=0.05-0.51). CONCLUSIONS Overall, MRI-based myelin imaging methods show a fairly good correlation with histology and a good reproducibility. However, the amount of validation data is too limited and the variability in performance between studies is too large to select the optimal MRI method for myelin quantification yet.
Collapse
Affiliation(s)
- Chris W J van der Weijden
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands.
| | - David Vállez García
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands; Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands.
| | - Ronald J H Borra
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands.
| | - Patrick Thurner
- Universitätsklinik für Radiologie und Nuklearmedizin, Medizinische Universität Wien, Währinger Gürtel 18-20, 1090 Wien, Austria.
| | - Jan F Meilof
- Multiple Sclerosis Center Noord Nederland, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands.
| | - Peter-Jan van Laar
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands; Department of Radiology, Zorggroep Twente, Zilvermeeuw 1, 7609 PP Almelo, the Netherlands.
| | - Rudi A J O Dierckx
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands.
| | - Ingomar W Gutmann
- Physics of Functional Material, Faculty of Physics, University of Vienna, Boltzmanngasse 5, 1090 Vienna, Austria.
| | - Erik F J de Vries
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands.
| |
Collapse
|
33
|
Ercan E, Varma G, Dimitrov IE, Xi Y, Pinho MC, Yu FF, Zhang S, Wang X, Madhuranthakam AJ, Lenkinski RE, Alsop DC, Vinogradov E. Combining inhomogeneous magnetization transfer and multipoint Dixon acquisition: Potential utility and evaluation. Magn Reson Med 2020; 85:2136-2144. [PMID: 33107146 PMCID: PMC7821205 DOI: 10.1002/mrm.28571] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 09/08/2020] [Accepted: 10/06/2020] [Indexed: 11/08/2022]
Abstract
PURPOSE The recently introduced inhomogeneous magnetization transfer (ihMT) method has predominantly been applied for imaging the central nervous system. Future applications of ihMT, such as in peripheral nerves and muscles, will involve imaging in the vicinity of adipose tissues. This work aims to systematically investigate the partial volume effect of fat on the ihMT signal and to propose an efficient fat-separation method that does not interfere with ihMT measurements. METHODS First, the influence of fat on ihMT signal was studied using simulations. Next, the ihMT sequence was combined with a multi-echo Dixon acquisition for fat separation. The sequence was tested in 9 healthy volunteers using a 3T human scanner. The ihMT ratio (ihMTR) values were calculated in regions of interest in the brain and the spinal cord using standard acquisition (no fat saturation), water-only, in-phase, and out-of-phase reconstructions. The values obtained were compared with a standard fat suppression method, spectral presaturation with inversion recovery. RESULTS Simulations showed variations in the ihMTR values in the presence of fat, depending on the TEs used. The IhMTR values in the brain and spinal cord derived from the water-only ihMT multi-echo Dixon images were in good agreement with values from the unsuppressed sequence. The ihMT-spectral presaturation with inversion recovery combination resulted in 24%-35% lower ihMTR values compared with the standard non-fat-suppressed acquisition. CONCLUSION The presence of fat within a voxel affects the ihMTR calculations. The IhMT multi-echo Dixon method does not compromise the observable ihMT effect and can potentially be used to remove fat influence in ihMT.
Collapse
Affiliation(s)
- Ece Ercan
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Gopal Varma
- Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Radiology, Boston, MA, USA
| | - Ivan E Dimitrov
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA.,Philips Healthcare, Gainesville, FL, USA
| | - Yin Xi
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Department of Population and Data Sciences, UT Southwestern Medical Center, Dallas, TX, USA
| | - Marco C Pinho
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Fang F Yu
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| | - Shu Zhang
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Department of Cancer Systems Imaging, UT MD Anderson Cancer Center, Houston, TX, USA
| | - Xinzeng Wang
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Global MR Application and Workflow, GE Healthcare, Houston, TX, USA
| | - Ananth J Madhuranthakam
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Robert E Lenkinski
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - David C Alsop
- Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Radiology, Boston, MA, USA
| | - Elena Vinogradov
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
34
|
Piredda GF, Hilbert T, Thiran JP, Kober T. Probing myelin content of the human brain with MRI: A review. Magn Reson Med 2020; 85:627-652. [PMID: 32936494 DOI: 10.1002/mrm.28509] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 08/12/2020] [Accepted: 08/17/2020] [Indexed: 12/11/2022]
Abstract
Rapid and efficient transmission of electric signals among neurons of vertebrates is ensured by myelin-insulating sheaths surrounding axons. Human cognition, sensation, and motor functions rely on the integrity of these layers, and demyelinating diseases often entail serious cognitive and physical impairments. Magnetic resonance imaging radically transformed the way these disorders are monitored, offering an irreplaceable tool to noninvasively examine the brain structure. Several advanced techniques based on MRI have been developed to provide myelin-specific contrasts and a quantitative estimation of myelin density in vivo. Here, the vast offer of acquisition strategies developed to date for this task is reviewed. Advantages and pitfalls of the different approaches are compared and discussed.
Collapse
Affiliation(s)
- Gian Franco Piredda
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland.,Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.,LTS5, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Tom Hilbert
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland.,Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.,LTS5, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Jean-Philippe Thiran
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.,LTS5, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Tobias Kober
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland.,Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.,LTS5, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
35
|
Varma G, Munsch F, Burns B, Duhamel G, Girard OM, Guidon A, Lebel RM, Alsop DC. Three-dimensional inhomogeneous magnetization transfer with rapid gradient-echo (3D ihMTRAGE) imaging. Magn Reson Med 2020; 84:2964-2980. [PMID: 32602958 DOI: 10.1002/mrm.28324] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 04/10/2020] [Accepted: 04/23/2020] [Indexed: 01/18/2023]
Abstract
PURPOSE To demonstrate the feasibility of integrating the magnetization transfer (MT) preparations required for inhomogeneous MT (ihMT) within an MPRAGE-style acquisition. Such a sequence allows for reduced power deposition and easy inclusion of other modules. METHODS An ihMT MPRAGE-style sequence (ihMTRAGE) was initially simulated to investigate acquisition of the 3D ihMT data sequentially, or in an interleaved manner. The ihMTRAGE sequence was implemented on a 3T clinical scanner to acquire ihMT data from the brain and spine. RESULTS Both simulations and in vivo data provided an ihMT signal that was significantly greater using a sequential ihMTRAGE acquisition, compared with an interleaved implementation. Comparison with a steady-state ihMT acquisition (defined as having one MT RF pulse between successive acquisition modules) demonstrated how ihMTRAGE allows for a reduction in average power deposition, or greater ihMT signal at equal average power deposition. Inclusion of a prospective motion-correction module did not significantly affect the ihMT signal obtained from regions of interest in the brain. The ihMTRAGE acquisition allowed combination with a spatial saturation module to reduce phase wrap artifacts in a cervical spinal cord acquisition. CONCLUSIONS Use of preparations necessary for ihMT experiments within an MPRAGE-style sequence provides a useful alternative for acquiring 3D ihMT data. Compared with our steady-state implementation, ihMTRAGE provided reduced power deposition, while allowing use of the maximum intensity from off-resonance RF pulses. The 3D ihMTRAGE acquisition allowed combination of other modules with the preparation necessary for ihMT experiments, specifically motion compensation and spatial saturation modules.
Collapse
Affiliation(s)
- Gopal Varma
- Division of MR Research, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Fanny Munsch
- Division of MR Research, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | | | | | | | | | | | - David C Alsop
- Division of MR Research, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
36
|
Carvalho VND, Hertanu A, Grélard A, Mchinda S, Soustelle L, Loquet A, Dufourc EJ, Varma G, Alsop DC, Thureau P, Girard OM, Duhamel G. MRI assessment of multiple dipolar relaxation time (T 1D) components in biological tissues interpreted with a generalized inhomogeneous magnetization transfer (ihMT) model. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 311:106668. [PMID: 31887555 DOI: 10.1016/j.jmr.2019.106668] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 11/19/2019] [Accepted: 12/10/2019] [Indexed: 05/24/2023]
Abstract
T1D, the relaxation time of dipolar order, is sensitive to slow motional processes. Thus T1D is a probe for membrane dynamics and organization that could be used to characterize myelin, the lipid-rich membrane of axonal fibers. A mono-component T1D model associated with a modified ihMT sequence was previously proposed for in vivo evaluation of T1D with MRI. However, experiments have suggested that myelinated tissues exhibit multiple T1D components probably due to a heterogeneous molecular mobility. A bi-component T1D model is proposed and implemented. ihMT images of ex-vivo, fixed rat spinal cord were acquired with multiple frequency alternation rate. Fits to data yielded two T1Ds of about 500 μs and 10 ms. The proposed model seems to further explore the complexity of myelin organization compared to the previously reported mono-component T1D model.
Collapse
Affiliation(s)
- Victor N D Carvalho
- Aix Marseille Univ, CNRS, CRMBM UMR 7339, Marseille, France; Aix Marseille Univ, CNRS, ICR UMR 7273, Marseille, France
| | | | - Axelle Grélard
- CBMN UMR 5248, CNRS University of Bordeaux, Bordeaux INP, Pessac, France
| | - Samira Mchinda
- Aix Marseille Univ, CNRS, CRMBM UMR 7339, Marseille, France
| | | | - Antoine Loquet
- CBMN UMR 5248, CNRS University of Bordeaux, Bordeaux INP, Pessac, France
| | - Erick J Dufourc
- CBMN UMR 5248, CNRS University of Bordeaux, Bordeaux INP, Pessac, France
| | - Gopal Varma
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| | - David C Alsop
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| | - Pierre Thureau
- CBMN UMR 5248, CNRS University of Bordeaux, Bordeaux INP, Pessac, France
| | | | | |
Collapse
|
37
|
Malik SJ, Teixeira RPAG, West DJ, Wood TC, Hajnal JV. Steady-state imaging with inhomogeneous magnetization transfer contrast using multiband radiofrequency pulses. Magn Reson Med 2019; 83:935-949. [PMID: 31538361 PMCID: PMC6881187 DOI: 10.1002/mrm.27984] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 08/13/2019] [Accepted: 08/15/2019] [Indexed: 02/05/2023]
Abstract
Purpose Inhomogeneous magnetization transfer (ihMT) is an emerging form of MRI contrast that may offer high specificity for myelinated tissue. Existing ihMT and pulsed MT sequences often use separate radiofrequency pulses for saturation and signal excitation. This study investigates the use of nonselective multiband radiofrequency pulses for simultaneous off‐resonance saturation and on‐resonance excitation specifically for generation of ihMT contrast within rapid steady‐state pulse sequences. Theory and Methods A matrix‐based signal modeling approach was developed and applied for both balanced steady state free precession and spoiled gradient echo sequences, accounting specifically for multiband pulses. Phantom experiments were performed using a combination of balanced steady state free precession and spoiled gradient echo sequences, and compared with model fits. A human brain imaging exam was performed using balanced steady state free precession sequences to demonstrate the achieved contrast. Results A simple signal model derived assuming instantaneous radiofrequency pulses was shown to agree well with full integration of the governing equations and provided fits to phantom data for materials with strong ihMT contrast (PL161 root mean square error = 0.9%, and hair conditioner root mean square error = 2.4%). In vivo ihMT ratio images showed the expected white matter contrast that has been seen by other ihMT investigations, and the observed ihMT ratios corresponded well with predictions. Conclusions ihMT contrast can be generated by integrating multiband radiofrequency pulses directly into both spoiled gradient echo and balanced steady state free precession sequences, and the presented signal modeling approach can be used to understand the acquired signals.
Collapse
Affiliation(s)
- Shaihan J Malik
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, King's College London, London, United Kingdom
| | - Rui P A G Teixeira
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, King's College London, London, United Kingdom
| | - Daniel J West
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, King's College London, London, United Kingdom
| | - Tobias C Wood
- Neuroimaging Department, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom
| | - Joseph V Hajnal
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, King's College London, London, United Kingdom
| |
Collapse
|
38
|
Duhamel G, Prevost VH, Cayre M, Hertanu A, Mchinda S, Carvalho VN, Varma G, Durbec P, Alsop DC, Girard OM. Validating the sensitivity of inhomogeneous magnetization transfer (ihMT) MRI to myelin with fluorescence microscopy. Neuroimage 2019; 199:289-303. [PMID: 31141736 DOI: 10.1016/j.neuroimage.2019.05.061] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 05/22/2019] [Accepted: 05/23/2019] [Indexed: 11/30/2022] Open
Abstract
Inhomogeneous Magnetization Transfer (ihMT) is a development from the MT MRI technique. IhMT can be considered as a dipolar order relaxation time (T1D) weighted imaging modality whose signal has shown an enhanced selectivity for myelin-rich structures. However, a formal validation of the ihMT sensitivity relative to a gold standard myelin density measurement has not yet been reported. To address this need, we compared ihMT MRI with green fluorescence protein (GFP) microscopy, in a study performed on genetically-modified plp-GFP mice, considered as a reference technique for myelin-content assessment. Various ihMT protocols consisting of variable T1D-filtering and radiofrequency power temporal distributions, were used for comparison with fluorescence microscopy. Strong and significant linear relationships (r2 (0.87-0.96), p < 0.0001) were found between GFP and ihMT ratio signals across brain regions for all tested protocol variants. Conventional MT ratios showed weaker correlations (r2 (0.24-0.78), p ≤ 0.02) and a much larger signal fraction unrelated to myelin, hence corresponding to a much lower specificity for myelin. T1D-filtering reduced the ihMT signal fraction not attributed to myelin by almost twofold relative to zero filtering suggesting that at least half of the unrelated signal has a substantially shorter T1D than myelin. Overall, these results strongly support the sensitivity of ihMT to myelin content.
Collapse
Affiliation(s)
- G Duhamel
- Aix Marseille Univ, CNRS, CRMBM - UMR 7339, Marseille, France.
| | - V H Prevost
- Aix Marseille Univ, CNRS, CRMBM - UMR 7339, Marseille, France
| | - M Cayre
- Aix Marseille Univ, CNRS, IBDM - UMR 7288, Marseille, France
| | - A Hertanu
- Aix Marseille Univ, CNRS, CRMBM - UMR 7339, Marseille, France
| | - S Mchinda
- Aix Marseille Univ, CNRS, CRMBM - UMR 7339, Marseille, France
| | - V N Carvalho
- Aix Marseille Univ, CNRS, CRMBM - UMR 7339, Marseille, France
| | - G Varma
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, 02215, USA
| | - P Durbec
- Aix Marseille Univ, CNRS, IBDM - UMR 7288, Marseille, France
| | - D C Alsop
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, 02215, USA
| | - O M Girard
- Aix Marseille Univ, CNRS, CRMBM - UMR 7339, Marseille, France
| |
Collapse
|
39
|
Battiston M, Schneider T, Grussu F, Yiannakas MC, Prados F, De Angelis F, Gandini Wheeler-Kingshott CAM, Samson RS. Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI. Magn Reson Med 2019; 82:1025-1040. [PMID: 31081239 DOI: 10.1002/mrm.27792] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 03/15/2019] [Accepted: 04/10/2019] [Indexed: 11/10/2022]
Abstract
PURPOSE To enable clinical applications of quantitative magnetization transfer (qMT) imaging by developing a fast method to map one of its fundamental model parameters, the bound pool fraction (BPF), in the human brain. THEORY AND METHODS The theory of steady-state MT in the fast-exchange approximation is used to provide measurements of BPF, and bound pool transverse relaxation time ( T 2 B ). A sequence that allows sampling of the signal during steady-state MT saturation is used to perform BPF mapping with a 10-min-long fully echo planar imaging-based MRI protocol, including inversion recovery T1 mapping and B1 error mapping. The approach is applied in 6 healthy subjects and 1 multiple sclerosis patient, and validated against a single-slice full qMT reference acquisition. RESULTS BPF measurements are in agreement with literature values using off-resonance MT, with average BPF of 0.114(0.100-0.128) in white matter and 0.068(0.054-0.085) in gray matter. Median voxel-wise percentage error compared with standard single slice qMT is 4.6%. Slope and intercept of linear regression between new and reference BPF are 0.83(0.81-0.85) and 0.013(0.11-0.16). Bland-Altman plot mean bias is 0.005. In the multiple sclerosis case, the BPF is sensitive to pathological changes in lesions. CONCLUSION The method developed provides accurate BPF estimates and enables shorter scan time compared with currently available approaches, demonstrating the potential of bringing myelin sensitive measurement closer to the clinic.
Collapse
Affiliation(s)
- Marco Battiston
- Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, Faculty of Brain Sciences, University College London, London, United Kingdom
| | | | - Francesco Grussu
- Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, Faculty of Brain Sciences, University College London, London, United Kingdom.,Centre for Medical Image Computing, Department of Computer Science, University College London, London, United Kingdom
| | - Marios C Yiannakas
- Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, Faculty of Brain Sciences, University College London, London, United Kingdom
| | - Ferran Prados
- Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, Faculty of Brain Sciences, University College London, London, United Kingdom.,Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.,Universitat Oberta de Catalunya, Barcelona, Spain
| | - Floriana De Angelis
- Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, Faculty of Brain Sciences, University College London, London, United Kingdom
| | - Claudia A M Gandini Wheeler-Kingshott
- Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, Faculty of Brain Sciences, University College London, London, United Kingdom.,Department of Brain and Behavioural Sciences, University of Pavia, Pavia, Italy.,Brain MRI 3T Research Centre, IRCCS Mondino Foundation, Pavia, Italy
| | - Rebecca S Samson
- Queen Square MS Centre, Department of Neuroinflammation, UCL Institute of Neurology, Faculty of Brain Sciences, University College London, London, United Kingdom
| |
Collapse
|
40
|
El Mendili MM, Querin G, Bede P, Pradat PF. Spinal Cord Imaging in Amyotrophic Lateral Sclerosis: Historical Concepts-Novel Techniques. Front Neurol 2019; 10:350. [PMID: 31031688 PMCID: PMC6474186 DOI: 10.3389/fneur.2019.00350] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2018] [Accepted: 03/21/2019] [Indexed: 01/13/2023] Open
Abstract
Amyotrophic lateral sclerosis (ALS) is the most common adult onset motor neuron disease with no effective disease modifying therapies at present. Spinal cord degeneration is a hallmark feature of ALS, highlighted in the earliest descriptions of the disease by Lockhart Clarke and Jean-Martin Charcot. The anterior horns and corticospinal tracts are invariably affected in ALS, but up to recently it has been notoriously challenging to detect and characterize spinal pathology in vivo. With recent technological advances, spinal imaging now offers unique opportunities to appraise lower motor neuron degeneration, sensory involvement, metabolic alterations, and interneuron pathology in ALS. Quantitative spinal imaging in ALS has now been used in cross-sectional and longitudinal study designs, applied to presymptomatic mutation carriers, and utilized in machine learning applications. Despite its enormous clinical and academic potential, a number of physiological, technological, and methodological challenges limit the routine use of computational spinal imaging in ALS. In this review, we provide a comprehensive overview of emerging spinal cord imaging methods and discuss their advantages, drawbacks, and biomarker potential in clinical applications, clinical trial settings, monitoring, and prognostic roles.
Collapse
Affiliation(s)
- Mohamed Mounir El Mendili
- Department of Neurology, Icahn School of Medicine at Mount Sinai, New York, NY, United States.,Biomedical Imaging Laboratory (LIB), Sorbonne University, CNRS, INSERM, Paris, France
| | - Giorgia Querin
- Biomedical Imaging Laboratory (LIB), Sorbonne University, CNRS, INSERM, Paris, France.,Department of Neurology, Pitié-Salpêtrière University Hospital (APHP), Paris, France
| | - Peter Bede
- Biomedical Imaging Laboratory (LIB), Sorbonne University, CNRS, INSERM, Paris, France.,Department of Neurology, Pitié-Salpêtrière University Hospital (APHP), Paris, France.,Computational Neuroimaging Group, Trinity College Dublin, Dublin, Ireland
| | - Pierre-François Pradat
- Biomedical Imaging Laboratory (LIB), Sorbonne University, CNRS, INSERM, Paris, France.,Department of Neurology, Pitié-Salpêtrière University Hospital (APHP), Paris, France
| |
Collapse
|
41
|
Varma G, Girard OM, Mchinda S, Prevost VH, Grant AK, Duhamel G, Alsop DC. Low duty-cycle pulsed irradiation reduces magnetization transfer and increases the inhomogeneous magnetization transfer effect. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 296:60-71. [PMID: 30212729 DOI: 10.1016/j.jmr.2018.08.004] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Revised: 07/27/2018] [Accepted: 08/18/2018] [Indexed: 06/08/2023]
Abstract
Intense off-resonant RF irradiation can lead to saturation of the macromolecular pool magnetization and enhance bound pool dipolar order responsible for the inhomogeneous magnetization transfer (ihMT) effect, but the intensity of RF power in human imaging studies is limited by safety constraints on RF heating. High RF intensities can still be achieved if applied in short pulses with low duty-cycle. Here we investigate the benefits of low duty-cycle irradiation for MT and ihMT studies with both theoretical and experimental methods. Solutions for pulsed irradiation of a two-pool model including dipolar order effects were implemented. Experiments were conducted at 3 T in the brain and through the calf of healthy human subjects. 2D echo planar images were acquired following a preparation of RF irradiation with a 2 s train of 5 ms pulses repeated from between 10 to 100 ms for duty-cycles (DCs) of 50% to 5%, and at varying offset frequencies, and time averaged RF powers. MT and ihMT data were measured in regions of interest within gray matter, white matter and muscle, and fit to the model. RF irradiation effects on signal intensity were reduced at 5% relative to 50% DCs. This reduced RF effect was much larger for single than dual frequency irradiation. 5% DC irradiation reduced single and dual frequency MT ratios but increased ihMT ratios up to 3 fold in brain tissues. Muscle ihMT increased by an even larger factor, depending on the frequency and applied power. The model predicted these changes with duty-cycle. The model fit the data well and constrained model parameters. Low duty-cycle pulsed irradiation reduces MT effects and markedly increases dipolar order effects. This approach is an attractive method to enhance ihMT signal-to-noise ratio and demonstrates a measurable ihMT effect in muscle tissue at 3 T under acceptable specific absorption rates. The effects of duty-cycle changes demonstrated in a separate MT/ihMT preparation provide a route for new applications in magnetization-prepared MRI sequences.
Collapse
Affiliation(s)
- G Varma
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02115, USA.
| | - O M Girard
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
| | - S Mchinda
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
| | - V H Prevost
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
| | - A K Grant
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02115, USA
| | - G Duhamel
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France
| | - D C Alsop
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
42
|
Geeraert BL, Lebel RM, Mah AC, Deoni SC, Alsop DC, Varma G, Lebel C. A comparison of inhomogeneous magnetization transfer, myelin volume fraction, and diffusion tensor imaging measures in healthy children. Neuroimage 2018; 182:343-350. [DOI: 10.1016/j.neuroimage.2017.09.019] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 07/24/2017] [Accepted: 09/08/2017] [Indexed: 12/16/2022] Open
|
43
|
Laule C, Moore GW. Myelin water imaging to detect demyelination and remyelination and its validation in pathology. Brain Pathol 2018; 28:750-764. [PMID: 30375119 PMCID: PMC8028667 DOI: 10.1111/bpa.12645] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Accepted: 07/09/2018] [Indexed: 12/11/2022] Open
Abstract
Damage to myelin is a key feature of multiple sclerosis (MS) pathology. Magnetic resonance imaging (MRI) has revolutionized our ability to detect and monitor MS pathology in vivo. Proton density, T1 and T2 can provide qualitative contrast weightings that yield superb in vivo visualization of central nervous system tissue and have proved invaluable as diagnostic and patient management tools in MS. However, standard clinical MR methods are not specific to the types of tissue damage they visualize, and they cannot detect subtle abnormalities in tissue that appears otherwise normal on conventional MRIs. Myelin water imaging is an MR method that provides in vivo measurement of myelin. Histological validation work in both human brain and spinal cord tissue demonstrates a strong correlation between myelin water and staining for myelin, validating myelin water as a marker for myelin. Myelin water varies throughout the brain and spinal cord in healthy controls, and shows good intra- and inter-site reproducibility. MS plaques show variably decreased myelin water fraction, with older lesions demonstrating the greatest myelin loss. Longitudinal study of myelin water can provide insights into the dynamics of demyelination and remyelination in plaques. Normal appearing brain and spinal cord tissues show reduced myelin water, an abnormality which becomes progressively more evident over a timescale of years. Diffusely abnormal white matter, which is evident in 20%-25% of MS patients, also shows reduced myelin water both in vivo and postmortem, and appears to originate from a primary lipid abnormality with relative preservation of myelin proteins. Active research is ongoing in the quest to refine our ability to image myelin and its perturbations in MS and other disorders of the myelin sheath.
Collapse
Affiliation(s)
- Cornelia Laule
- RadiologyUniversity of British ColumbiaVancouverBCCanada
- Pathology & Laboratory MedicineUniversity of British ColumbiaVancouverBCCanada
- Physics & AstronomyUniversity of British ColumbiaVancouverBCCanada
- International Collaboration on Repair Discoveries (ICORD)University of British ColumbiaVancouverBCCanada
| | - G.R. Wayne Moore
- Pathology & Laboratory MedicineUniversity of British ColumbiaVancouverBCCanada
- International Collaboration on Repair Discoveries (ICORD)University of British ColumbiaVancouverBCCanada
- Medicine (Neurology)University of British ColumbiaVancouverBCCanada
| |
Collapse
|
44
|
Ercan E, Varma G, Mädler B, Dimitrov IE, Pinho MC, Xi Y, Wagner BC, Davenport EM, Maldjian JA, Alsop DC, Lenkinski RE, Vinogradov E. Microstructural correlates of 3D steady-state inhomogeneous magnetization transfer (ihMT) in the human brain white matter assessed by myelin water imaging and diffusion tensor imaging. Magn Reson Med 2018; 80:2402-2414. [PMID: 29707813 DOI: 10.1002/mrm.27211] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Revised: 03/14/2018] [Accepted: 03/15/2018] [Indexed: 02/05/2023]
Abstract
PURPOSE To compare the recently introduced inhomogeneous magnetization transfer (ihMT) technique with more established MRI techniques including myelin water imaging (MWI) and diffusion tensor imaging (DTI), and to evaluate the microstructural attributes correlating with this new contrast method in the human brain white matter. METHODS Eight adult healthy volunteers underwent T1 -weighted, ihMT, MWI, and DTI imaging on a 3T human scanner. The ihMT ratio (ihMTR), myelin water fraction (MWF), fractional anisotropy (FA), radial diffusivity (RD), axial diffusivity (AD), and mean diffusivity (MD) values were calculated from different white matter tracts. The angle ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>θ</mml:mi></mml:math> ) between the directions of the principal eigenvector, as measured by DTI, and the main magnetic field was calculated for all voxels from various fiber tracts. The ihMTR was correlated with MWF and DTI metrics. RESULTS A strong correlation was found between ihMTR and MWF (ρ = 0.77, P < 0.0001). This was followed by moderate to weak correlations between ihMTR and DTI metrics: RD (ρ = -0.30, P < 0.0001), FA (ρ = 0.20, P < 0.0001), MD (ρ = -0.19, P < 0.0001), AD (ρ = 0.02, P < 0.0001). A strong correlation was found between ihMTR and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>θ</mml:mi></mml:math> (ρ = -0.541, P < 0.0001). CONCLUSION The strong correlation with myelin water imaging and its low coefficient of variation suggest that ihMT has the potential to become a new structural imaging marker of myelin. The substantial orientational dependence of ihMT should be taken into account when evaluating and quantitatively interpreting ihMT results.
Collapse
Affiliation(s)
- Ece Ercan
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Gopal Varma
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | | | - Ivan E Dimitrov
- Philips Healthcare, Gainesville, Florida.,Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Marco C Pinho
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas.,Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Yin Xi
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Benjamin C Wagner
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Elizabeth M Davenport
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Joseph A Maldjian
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas.,Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - David C Alsop
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Robert E Lenkinski
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas.,Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Elena Vinogradov
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas.,Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| |
Collapse
|
45
|
Van Obberghen E, Mchinda S, le Troter A, Prevost VH, Viout P, Guye M, Varma G, Alsop DC, Ranjeva JP, Pelletier J, Girard O, Duhamel G. Evaluation of the Sensitivity of Inhomogeneous Magnetization Transfer (ihMT) MRI for Multiple Sclerosis. AJNR Am J Neuroradiol 2018; 39:634-641. [PMID: 29472299 DOI: 10.3174/ajnr.a5563] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Accepted: 12/22/2017] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Inhomogeneous magnetization transfer is a new endogenous MR imaging contrast mechanism that has demonstrated high specificity for myelin. Here, we tested the hypothesis that inhomogeneous magnetization transfer is sensitive to pathology in a population of patients with relapsing-remitting MS in a way that both differs from and complements conventional magnetization transfer. MATERIALS AND METHODS Twenty-five patients with relapsing-remitting MS and 20 healthy volunteers were enrolled in a prospective MR imaging research study, whose protocol included anatomic imaging, standard magnetization transfer, and inhomogeneous magnetization transfer imaging. Magnetization transfer and inhomogeneous magnetization transfer ratios measured in normal-appearing brain tissue and in MS lesions of patients were compared with values measured in control subjects. The potential association of inhomogeneous magnetization transfer ratio variations with the clinical scores (Expanded Disability Status Scale) of patients was further evaluated. RESULTS The magnetization transfer ratio and inhomogeneous magnetization transfer ratio measured in the thalami and frontal, occipital, and temporal WM of patients with MS were lower compared with those of controls (P < .05). The mean inhomogeneous magnetization transfer ratio measured in lesions was lower than that in normal-appearing WM (P < .05). Significant (P < .05) negative correlations were found between the clinical scores and inhomogeneous magnetization transfer ratio measured in normal-appearing WM structures. Weaker nonsignificant correlation trends were found for the magnetization transfer ratio. CONCLUSIONS The sensitivity of the inhomogeneous magnetization transfer technique for MS was highlighted by the reduction in the inhomogeneous magnetization transfer ratio in MS lesions and in normal-appearing WM of patients compared with controls. Stronger correlations with the Expanded Disability Status Scale score were obtained with the inhomogeneous magnetization transfer ratio compared with the standard magnetization transfer ratio, which may be explained by the higher specificity of inhomogeneous magnetization transfer for myelin.
Collapse
Affiliation(s)
- E Van Obberghen
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| | - S Mchinda
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| | - A le Troter
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| | - V H Prevost
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| | - P Viout
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| | - M Guye
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| | - G Varma
- Department of Radiology (G.V., D.C.A.), Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - D C Alsop
- Department of Radiology (G.V., D.C.A.), Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - J-P Ranjeva
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| | - J Pelletier
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
- Aix-Marseille University (J.P.), Assistance Publique des Hôpitaux de Marseille (APHM), Hôpital de La Timone, Pôle de Neurosciences Cliniques, Service de Neurologie, Marseille, France
| | - O Girard
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| | - G Duhamel
- From Aix-Marseille Université (E.V.O., S.M., A.l.T., V.H.P., P.V., M.G., J.-P.R., J.P., O.G., G.D.), Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339 Centre National de Recherche Scientifique (CNRS), Marseille, France
| |
Collapse
|
46
|
Sled JG. Modelling and interpretation of magnetization transfer imaging in the brain. Neuroimage 2017; 182:128-135. [PMID: 29208570 DOI: 10.1016/j.neuroimage.2017.11.065] [Citation(s) in RCA: 89] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 11/19/2017] [Accepted: 11/29/2017] [Indexed: 01/09/2023] Open
Abstract
Magnetization transfer contrast has yielded insight into brain tissue microstructure changes across the lifespan and in a range of disorders. This progress has been aided by the development of quantitative magnetization transfer imaging techniques able to extract intrinsic properties of the tissue that are independent of the specifics of the data acquisition. While the tissue properties extracted by these techniques do not map directly onto specific cellular structures or pathological processes, a growing body of work from animal models and histopathological correlations aids the in vivo interpretation of magnetization transfer properties of tissue. This review examines the biophysical models that have been developed to describe magnetization transfer contrast in tissue as well as the experimental evidence for the biological interpretation of magnetization transfer data in health and disease.
Collapse
Affiliation(s)
- John G Sled
- Hospital for Sick Children, Mouse Imaging Centre, Toronto, Ontario, Canada; Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
| |
Collapse
|
47
|
Rasoanandrianina H, Grapperon AM, Taso M, Girard OM, Duhamel G, Guye M, Ranjeva JP, Attarian S, Verschueren A, Callot V. Region-specific impairment of the cervical spinal cord (SC) in amyotrophic lateral sclerosis: A preliminary study using SC templates and quantitative MRI (diffusion tensor imaging/inhomogeneous magnetization transfer). NMR IN BIOMEDICINE 2017; 30:e3801. [PMID: 28926131 DOI: 10.1002/nbm.3801] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 07/24/2017] [Accepted: 08/07/2017] [Indexed: 06/07/2023]
Abstract
In this preliminary study, our objective was to investigate the potential of high-resolution anatomical imaging, diffusion tensor imaging (DTI) and conventional/inhomogeneous magnetization transfer imaging [magnetization transfer (MT)/inhomogeneous magnetization transfer (ihMT)] at 3 T, analyzed with template-extracted regions of interest, to measure the atrophy and structural changes of white (WM) and gray (GM) matter spinal cord (SC) occurring in patients with amyotrophic lateral sclerosis (ALS). Ten patients with ALS and 20 age-matched healthy controls were recruited. SC GM and WM areas were automatically segmented using dedicated templates. Atrophy indices were evaluated from T2 *-weighted images at each vertebral level from cervical C1 to C6. DTI and ihMT metrics were quantified within the corticospinal tract (CST), posterior sensory tract (PST) and anterior GM (aGM) horns at the C2 and C5 levels. Clinical disabilities of patients with ALS were evaluated using the Revised ALS Functional Rating Scale, upper motor neuron (UMN) and Medical Research Council scorings, and correlated with MR metrics. Compared with healthy controls, GM and WM atrophy was observed in patients with ALS, especially at lower cervical levels, where a strong correlation was also observed between GM atrophy and the UMN score (R = -0.75, p = 0.05 at C6). Interestingly, a significant decrease in ihMT ratio was found in all regions of interest (p < 0.0008), fractional anisotropy (FA) and MT ratios decreased significantly in CST, especially at C5 (p < 0.005), and λ// (axial diffusivity) decreased significantly in CST (p = 0.0004) and PST (p = 0.003) at C2. Strong correlations between MRI metrics and clinical scores were also found (0.47 < |R| < 0.87, p < 0.05). Altogether, these preliminary results suggest that high-resolution anatomical imaging and ihMT imaging, in addition to DTI, are valuable for the characterization of SC tissue impairment in ALS. In this study, in addition to an important SC WM demyelination, we also observed, for the first time in ALS, impairments of cervical aGM.
Collapse
Affiliation(s)
- Henitsoa Rasoanandrianina
- Aix-Marseille Université, CNRS, APHM, CRMBM, Hôpital de la Timone, CEMEREM, Marseille, France
- iLab-Spine International Associated Laboratory, Marseille-Montreal, France-Canada
- Aix-Marseille Université, IFSTTAR, LBA UMR T 24, Marseille, France
| | - Aude-Marie Grapperon
- Centre de Référence des Maladies neuro-musculaires et de la SLA, Hopital de La Timone, Marseille, France
| | - Manuel Taso
- Aix-Marseille Université, CNRS, APHM, CRMBM, Hôpital de la Timone, CEMEREM, Marseille, France
- iLab-Spine International Associated Laboratory, Marseille-Montreal, France-Canada
- Aix-Marseille Université, IFSTTAR, LBA UMR T 24, Marseille, France
| | - Olivier M Girard
- Aix-Marseille Université, CNRS, APHM, CRMBM, Hôpital de la Timone, CEMEREM, Marseille, France
| | - Guillaume Duhamel
- Aix-Marseille Université, CNRS, APHM, CRMBM, Hôpital de la Timone, CEMEREM, Marseille, France
| | - Maxime Guye
- Aix-Marseille Université, CNRS, APHM, CRMBM, Hôpital de la Timone, CEMEREM, Marseille, France
| | - Jean-Philippe Ranjeva
- Aix-Marseille Université, CNRS, APHM, CRMBM, Hôpital de la Timone, CEMEREM, Marseille, France
| | - Shahram Attarian
- Centre de Référence des Maladies neuro-musculaires et de la SLA, Hopital de La Timone, Marseille, France
- Aix Marseille Université, INSERM, GMGF, Marseille, France
| | - Annie Verschueren
- Centre de Référence des Maladies neuro-musculaires et de la SLA, Hopital de La Timone, Marseille, France
| | - Virginie Callot
- Aix-Marseille Université, CNRS, APHM, CRMBM, Hôpital de la Timone, CEMEREM, Marseille, France
- iLab-Spine International Associated Laboratory, Marseille-Montreal, France-Canada
| |
Collapse
|
48
|
Mchinda S, Varma G, Prevost VH, Le Troter A, Rapacchi S, Guye M, Pelletier J, Ranjeva J, Alsop DC, Duhamel G, Girard OM. Whole brain inhomogeneous magnetization transfer (ihMT) imaging: Sensitivity enhancement within a steady‐state gradient echo sequence. Magn Reson Med 2017; 79:2607-2619. [DOI: 10.1002/mrm.26907] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 07/18/2017] [Accepted: 08/17/2017] [Indexed: 02/05/2023]
Affiliation(s)
| | - Gopal Varma
- Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical SchoolBostonMassachusettsUSA
| | | | | | | | - Maxime Guye
- Aix Marseille Univ, CNRS, CRMBM UMR 7339MarseilleFrance
- Aix Marseille Univ, APHM, Hôpital de La Timone, Pôle d'Imagerie Médicale, CEMEREMMarseilleFrance
| | - Jean Pelletier
- Aix Marseille Univ, CNRS, CRMBM UMR 7339MarseilleFrance
- Aix Marseille Univ, APHM, Hôpital de La Timone, Pôle de Neurosciences Cliniques, Service de NeurologieMarseilleFrance
| | | | - David C. Alsop
- Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical SchoolBostonMassachusettsUSA
| | | | | |
Collapse
|
49
|
Lee JS, Regatte RR, Jerschow A. Magnetization transfer in a partly deuterated lyotropic liquid crystal by single- and dual-frequency RF irradiations. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2017; 281:141-150. [PMID: 28595121 PMCID: PMC5537047 DOI: 10.1016/j.jmr.2017.05.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2017] [Revised: 05/26/2017] [Accepted: 05/29/2017] [Indexed: 05/08/2023]
Abstract
The mechanism of magnetization transfer (MT) in a lyotropic liquid crystal made of sodium dodecyl sulfate, decanol, and water molecules is investigated by using deuterated molecules and single- and dual-frequency RF irradiations. The resulting Z-spectra suggest that the decanol molecules are mainly responsible for the MT effects in this system, through proton exchange to water. This is further confirmed by monitoring the relaxation of dipolar order, which allows one to estimate the transfer rate of magnetization from decanol to water. The potential benefits of using dual-frequency RF irradiation for inducing MT effects are explored through numerical solutions to a MT model based on Provotorov's partial saturation theory.
Collapse
Affiliation(s)
- Jae-Seung Lee
- Department of Radiology, New York University Langone Medical Center, New York, NY 10016, USA; Department of Chemistry, New York University, New York, NY 10003, USA.
| | - Ravinder R Regatte
- Department of Radiology, New York University Langone Medical Center, New York, NY 10016, USA
| | - Alexej Jerschow
- Department of Chemistry, New York University, New York, NY 10003, USA
| |
Collapse
|
50
|
Prevost VH, Girard OM, Mchinda S, Varma G, Alsop DC, Duhamel G. Optimization of inhomogeneous magnetization transfer (ihMT) MRI contrast for preclinical studies using dipolar relaxation time (T 1D ) filtering. NMR IN BIOMEDICINE 2017; 30:e3706. [PMID: 28195663 DOI: 10.1002/nbm.3706] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 01/10/2017] [Accepted: 01/11/2017] [Indexed: 06/06/2023]
Abstract
A pulsed inhomogeneous magnetization transfer (ihMT)-prepared fast imaging sequence was implemented at 11.75 T for preclinical studies on mouse central nervous system. A strategy based on filtering the ihMT signal originating from short dipolar relaxation time (T1D ) components is proposed. It involves increasing the repetition time of consecutive radiofrequency (RF) pulses of the dual saturation and allows improved signal specificity for long T1D myelinated structures. Furthermore, frequency offset, power and timing saturation parameters were adjusted to optimize the ihMT sensitivity. The optimization of the ihMT sensitivity, whilst preserving the strong specificity for the long T1D component of myelinated tissues, allowed measurements of ihMT ratios on the order of 4-5% in white matter (WM), 2.5% in gray matter (GM) and 1-1.3% in muscle. This led to high relative ihMT contrasts between myelinated tissues and others (~3-4 between WM and muscle, and ≥2 between GM and muscle). Conversely, higher ihMT ratios (~6-7% in WM) could be obtained using minimal T1D filtering achieved with short saturation pulse repetition time or cosine-modulated pulses for the dual-frequency saturation. This study represents a first stage in the process of validating ihMT as a myelin biomarker by providing optimized ihMT preclinical sequences, directly transposable and applicable to other preclinical magnetic fields and scanners. Finally, ihMT ratios measured in various central nervous system areas are provided for future reference.
Collapse
Affiliation(s)
- V H Prevost
- Aix Marseille Université, CNRS, Marseille, France
| | - O M Girard
- Aix Marseille Université, CNRS, Marseille, France
| | - S Mchinda
- Aix Marseille Université, CNRS, Marseille, France
| | - G Varma
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - D C Alsop
- Department of Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - G Duhamel
- Aix Marseille Université, CNRS, Marseille, France
| |
Collapse
|