1
|
Martin-Alarcon L, Govedarica A, Ewoldt RH, Bryant SL, Jay GD, Schmidt TA, Trifkovic M. Scale-Dependent Rheology of Synovial Fluid Lubricating Macromolecules. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2306207. [PMID: 38161247 DOI: 10.1002/smll.202306207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Revised: 11/20/2023] [Indexed: 01/03/2024]
Abstract
Synovial fluid (SF) is the complex biofluid that facilitates the exceptional lubrication of articular cartilage in joints. Its primary lubricating macromolecules, the linear polysaccharide hyaluronic acid (HA) and the mucin-like glycoprotein proteoglycan 4 (PRG4 or lubricin), interact synergistically to reduce boundary friction. However, the precise manner in which these molecules influence the rheological properties of SF remains unclear. This study aimed to elucidate this by employing confocal microscopy and multiscale rheometry to examine the microstructure and rheology of solutions containing recombinant human PRG4 (rhPRG4) and HA. Contrary to previous assumptions of an extensive HA-rhPRG4 network, it is discovered that rhPRG4 primarily forms stiff, gel-like aggregates. The properties of these aggregates, including their size and stiffness, are found to be influenced by the viscoelastic characteristics of the surrounding HA matrix. Consequently, the rheology of this system is not governed by a single length scale, but instead responds as a disordered, hierarchical network with solid-like rhPRG4 aggregates distributed throughout the continuous HA phase. These findings provide new insights into the biomechanical function of PRG4 in cartilage lubrication and may have implications in the development of HA-based therapies for joint diseases like osteoarthritis.
Collapse
Affiliation(s)
- Leonardo Martin-Alarcon
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Aleksandra Govedarica
- Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Randy H Ewoldt
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Steven L Bryant
- Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Gregory D Jay
- Department of Emergency Medicine - Warren Alpert Medical School & School of Engineering, Brown University, Providence, RI, 02912, USA
| | - Tannin A Schmidt
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Milana Trifkovic
- Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB, T2N 1N4, Canada
| |
Collapse
|
2
|
Ninkovic N, Sparks HD, Ponjevic D, Muench G, Biernaskie JA, Krawetz RJ. Proteoglycan 4 (PRG4) treatment improves skin wound healing in a porcine model. FASEB J 2024; 38:e23547. [PMID: 38498368 DOI: 10.1096/fj.202301289rrr] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 02/08/2024] [Accepted: 02/26/2024] [Indexed: 03/20/2024]
Abstract
Proteoglycan 4 (PRG4) is a boundary lubricant originally identified in articular cartilage and has been since shown to have immunomodulation and antifibrotic properties. Previously, we have demonstrated that recombinant human (rh)PRG4 treatment accelerates auricular cartilage injury closure through an inhibition of the fibrotic response, and promotion of tissue regeneration in mice. The purpose of the current study was to examine the effects of rhPRG4 treatment (vs. a DMSO carried control) on full-thickness skin wound healing in a preclinical porcine model. Our findings suggest that while rhPRG4 did not significantly accelerate nor impede full-thickness skin wound closure, it did improve repair quality by decreasing molecular markers of fibrosis and increasing re-vascularization. We also demonstrated that rhPRG4 treatment increased dermal adipose tissue during the healing process specifically by retaining adipocytes in the wound area but did not inhibit lipolysis. Overall, the results of the current study have demonstrated that rhPRG4 acts as antifibrotic agent and regulates dermal adipose tissue during the healing processes resulting in a tissue with a trajectory that more resembles the native skin vs. a fibrotic patch. This study provides strong rationale to examine if rhPRG4 can improve regeneration in human wounds.
Collapse
Affiliation(s)
- Nicoletta Ninkovic
- Department of Biochemistry and Molecular Biology, University of Calgary, Calgary, Alberta, Canada
- McCaig Institute for Bone & Joint Health, University of Calgary, Calgary, Alberta, Canada
| | - Holly D Sparks
- McCaig Institute for Bone & Joint Health, University of Calgary, Calgary, Alberta, Canada
- Faculty of Veterinary Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Dragana Ponjevic
- McCaig Institute for Bone & Joint Health, University of Calgary, Calgary, Alberta, Canada
- Faculty of Veterinary Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Greg Muench
- Faculty of Veterinary Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Jeff A Biernaskie
- Faculty of Veterinary Medicine, University of Calgary, Calgary, Alberta, Canada
- Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada
| | - Roman J Krawetz
- McCaig Institute for Bone & Joint Health, University of Calgary, Calgary, Alberta, Canada
- Faculty of Veterinary Medicine, University of Calgary, Calgary, Alberta, Canada
- Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, Canada
- Department Cell Biology and Anatomy, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
3
|
Ghelich P, Samandari M, Hassani Najafabadi A, Tanguay A, Quint J, Menon N, Ghanbariamin D, Saeedinejad F, Alipanah F, Chidambaram R, Krawetz R, Nuutila K, Toro S, Barnum L, Jay GD, Schmidt TA, Tamayol A. Dissolvable Immunomodulatory Microneedles for Treatment of Skin Wounds. Adv Healthc Mater 2024:e2302836. [PMID: 38299437 DOI: 10.1002/adhm.202302836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 12/21/2023] [Indexed: 02/02/2024]
Abstract
Sustained inflammation can halt or delay wound healing, and macrophages play a central role in wound healing. Inflammatory macrophages are responsible for the removal of pathogens, debris, and neutrophils, while anti-inflammatory macrophages stimulate various regenerative processes. Recombinant human Proteoglycan 4 (rhPRG4) is shown to modulate macrophage polarization and to prevent fibrosis and scarring in ear wound healing. Here, dissolvable microneedle arrays (MNAs) carrying rhPRG4 are engineered for the treatment of skin wounds. The in vitro experiments suggest that rhPRG4 modulates the inflammatory function of bone marrow-derived macrophages. Degradable and detachable microneedles are developed from gelatin methacryloyl (GelMA) attach to a dissolvable gelatin backing. The developed MNAs are able to deliver a high dose of rhPRG4 through the dissolution of the gelatin backing post-injury, while the GelMA microneedles sustain rhPRG4 bioavailability over the course of treatment. In vivo results in a murine model of full-thickness wounds with impaired healing confirm a decrease in inflammatory biomarkers such as TNF-α and IL-6, and an increase in angiogenesis and collagen deposition. Collectively, these results demonstrate rhPRG4-incorporating MNA is a promising platform in skin wound healing applications.
Collapse
Affiliation(s)
- Pejman Ghelich
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Mohamadmahdi Samandari
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Alireza Hassani Najafabadi
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Adam Tanguay
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Jacob Quint
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Nikhil Menon
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Delaram Ghanbariamin
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Farnoosh Saeedinejad
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Fatemeh Alipanah
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Ramaswamy Chidambaram
- Center for Comparative Medicine, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Roman Krawetz
- McCaig Institute for Bone & Joint Health, University of Calgary, Calgary, AB, T2N 4Z6, Canada
- Department of Surgery, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Kristo Nuutila
- US Army Institute of Surgical Research, Fort Sam Houston, Texas, 78234, USA
| | - Steven Toro
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Lindsay Barnum
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Gregory D Jay
- Emergency Medicine, Brown University, Providence, RI, 02908, USA
| | - Tannin A Schmidt
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Ali Tamayol
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, CT, 06030, USA
| |
Collapse
|
4
|
Menon NG, Tanguay AP, Zhou L, Zhang LX, Bobst CE, Han M, Ghosh M, Greene GW, Deymier A, Sullivan BD, Chen Y, Jay GD, Schmidt TA. A structural and functional comparison between two recombinant human lubricin proteins: Recombinant human proteoglycan-4 (rhPRG4) vs ECF843. Exp Eye Res 2023; 235:109643. [PMID: 37678729 PMCID: PMC10691279 DOI: 10.1016/j.exer.2023.109643] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/22/2023] [Accepted: 09/04/2023] [Indexed: 09/09/2023]
Abstract
Proteoglycan 4 (PRG4, lubricin) is a mucin-like glycoprotein present on the ocular surface that has both boundary lubricating and anti-inflammatory properties. Full-length recombinant human PRG4 (rhPRG4) has been shown to be clinically effective in improving signs and symptoms of dry eye disease (DED). In vitro, rhPRG4 has been shown to reduce inflammation-induced cytokine production and NFκB activity in corneal epithelial cells, as well as to bind to and inhibit MMP-9 activity. A different form of recombinant human lubricin (ECF843), produced from the same cell line as rhPRG4 but manufactured using a different process, was recently assessed in a DED clinical trial. However, ECF843 did not significantly improve signs or symptoms of DED compared to vehicle. Initial published characterization of ECF843 showed it had a smaller hydrodynamic diameter and was less negatively charged than native PRG4. Further examination of the structural and functional properties of ECF843 and rhPRG4 could contribute to the understanding of what led to their disparate clinical efficacy. Therefore, the objective of this study was to characterize and compare rhPRG4 and ECF843 in vitro, both biophysically and functionally. Hydrodynamic diameter and charge were measured by dynamic light scattering (DLS) and zeta potential, respectively. Size and molecular weight was determined for individual species by size exclusion chromatography (SEC) with in-line DLS and multi-angle light scattering (MALS). Bond structure was measured by Raman spectroscopy, and sedimentation properties were measured by analytical ultracentrifugation (AUC). Functionally, MMP-9 inhibition was measured using a commercial MMP-9 activity kit, coefficient of friction was measured using an established boundary lubrication test at a latex-glass interface, and collagen 1-binding ability was measured by quart crystal microbalance with dissipation (QCMD). Additionally, the ability of rhPRG4 and ECF843 to inhibit urate acid crystal formation and cell adhesion was assessed. ECF843 had a significantly smaller hydrodynamic diameter and was less negatively charged than rhPRG4, as assessed by DLS and zeta potential. Size was further explored with SEC-DLS-MALS, which indicated that while rhPRG4 had 3 main peaks, corresponding to monomer, dimer, and multimer as expected, ECF843 had 2 peaks that were similar in size and molecular weight compared to rhPRG4's monomer peak and a third peak that was significantly smaller in both size and molar mass than the corresponding peak of rhPRG4. Raman spectroscopy demonstrated that ECF843 had significantly more disulfide bonds, which are functionally determinant structures, relative to the carbon-carbon backbone compared to rhPRG4, and AUC indicated that ECF843 was more compact than rhPRG4. Functionally, ECF843 was significantly less effective at inhibiting MMP-9 activity and functioning as a boundary lubricant compared to rhPRG4, as well as being slower to bind to collagen 1. Additionally, ECF843 was significantly less effective at inhibiting urate acid crystal formation and at preventing cell adhesion. Collectively, these data demonstrate ECF843 and rhPRG4 are significantly different in both structure and function. Given that a protein's structure sets the foundation for its interactions with other molecules and tissues in vivo, which ultimately determine its function, these differences most likely contributed to the disparate DED clinical trial results.
Collapse
Affiliation(s)
- Nikhil G Menon
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Adam P Tanguay
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Libo Zhou
- Biomedical Engineering Department, University of Connecticut, Storrs, CT, USA
| | - Ling X Zhang
- Emergency Medicine, Brown University, Providence, RI, USA
| | - Cedric E Bobst
- Department of Chemistry, University of Massachusetts Amherst, Amherst, MA, USA
| | - Mingyu Han
- Institute for Frontier Materials and ARC Centre of Excellence for Electromaterials Science, Deakin University, Melbourne, Victoria, Australia; Commonwealth Scientific and Industrial Research Organization (CSIRO), Agriculture and Food, Werribee, Victoria, Australia
| | - Mallika Ghosh
- Department of Cell Biology, School of Medicine, UConn Health, Farmington, CT, USA
| | - George W Greene
- Institute for Frontier Materials and ARC Centre of Excellence for Electromaterials Science, Deakin University, Melbourne, Victoria, Australia; Department of Chemistry and Biochemistry, La Trobe Institute for Molecular Science, La Trobe University, Melbourne, Australia
| | - Alix Deymier
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | | | - Yupeng Chen
- Biomedical Engineering Department, University of Connecticut, Storrs, CT, USA
| | - Gregory D Jay
- Emergency Medicine, Brown University, Providence, RI, USA
| | - Tannin A Schmidt
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA.
| |
Collapse
|
5
|
Matheson A, Regmi SC, Martin-Alarcon L, Jay GD, Scott WM, Schmidt TA. Proteoglycan-4 and hyaluronan composition in synovial fluid and serum from clinical equine subjects: relationship to cartilage boundary lubrication and viscosity of synovial fluid. Connect Tissue Res 2021; 62:369-380. [PMID: 32306780 DOI: 10.1080/03008207.2020.1751140] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Purpose: In experimental models of equine joint-injury and osteoarthritis synovial fluid (SF) composition (proteoglycan-4, hyaluronan) can vary, along with changes to SF mechanical function (lubrication, viscosity). The study hypotheses were a) clinical equine joint-injury and disease results in altered SF composition and diminished mechanical function, and b) serum composition (proteoglycan-4 or hyaluronan) changes concurrently. The objectives were to characterize composition (proteoglycan-4, hyaluronan), and function of SF and serum from normal horses compared to clinical groups: osteoarthritis, acute-joint-injury, and osteochondrosis.Materials and Methods: Equine samples of SF (from various joints) and blood were collected at the point-of-care. Proteoglycan-4 concentrations were measured by amplified-luminescence-proximity-assay and enzyme-linked-immunosorbent-assay in SF and serum, respectively. Molecular-weight of hyaluronan was characterized by agarose-gel-electrophoresis, and concentrations were measured by enzyme-linked-immunosorbent-assay kit. Biomechanical function of SF was characterized by an in vitro cartilage-on-cartilage friction test, and viscosity test.Results: SF proteoglycan-4 concentration increased in acute-joint-injury (1185 ± 276 versus normal 205 ± 106 µg/mL, µ± SEM, p < 0.01), with increased percentage of lower molecular-weight hyaluronan in acute-joint-injury and osteochondrosis. SF and serum proteoglycan-4 concentrations were correlated in normal horses (r2 = 0.85, p < 0.05), but not in clinical groups. Cartilage-lubricating ability was unchanged, although steady-shear viscosity of acute-joint-injury SF decreased from normal.Conclusion: Composition of SF from cases of equine acute-joint-injury changed; both proteoglycan-4 concentration and hyaluronan molecular-weight were altered, with decreased SF viscosity, but no associated changes to serum. Serum proteoglycan-4 and hyaluronan concentrations alone may not be useful biomarkers for equine joint-injury or disease.
Collapse
Affiliation(s)
- Austyn Matheson
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | - Suresh C Regmi
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | | | - Gregory D Jay
- Department of Emergency Medicine - Warren Alpert Medical School & School of Engineering, Brown University, Providence, RI, USA
| | - W Michael Scott
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada.,Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| | - Tannin A Schmidt
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada.,Biomedical Engineering Department, University of Connecticut Health Center, Farmington, CT, USA
| |
Collapse
|
6
|
Menon NG, Goyal R, Lema C, Woods PS, Tanguay AP, Morin AA, Das N, Jay GD, Krawetz RJ, Dufour A, Shapiro LH, Redfern RL, Ghosh M, Schmidt TA. Proteoglycan 4 (PRG4) expression and function in dry eye associated inflammation. Exp Eye Res 2021; 208:108628. [PMID: 34048779 DOI: 10.1016/j.exer.2021.108628] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 04/30/2021] [Accepted: 05/17/2021] [Indexed: 12/21/2022]
Abstract
Dry eye disease (DED) affects hundreds of millions of people worldwide. It is characterized by the production of inflammatory cytokines and chemokines as well as damaging matrix metalloproteinases (MMPs) at the ocular surface. While proteoglycan 4 (PRG4), a mucin-like glycoprotein present at the ocular surface, is most well known as a boundary lubricant that contributes to ocular surface integrity, it has been shown to blunt inflammation in various cell types, suggesting a dual mechanism of action. Recently, full-length recombinant human PRG4 (rhPRG4) has been shown to improve signs and symptoms of DED in humans. However, there remains a significant need for basic science research on rhPRG4's biological properties and its potential therapeutic mechanisms of action in treating DED. Therefore, the objectives of this study were to characterize endogenous PRG4 expression by telomerase-immortalized human corneal epithelial (hTCEpi) cells, examine whether exogenous rhPRG4 modulates cytokine and chemokine secretion in response to dry eye associated inflammation (TNFα and IL-1β), explore interactions between rhPRG4 and MMP-9, and understand how experimental dry eye (EDE) in mice affects PRG4 expression. PRG4 secretion from hTCEpi cells was quantified by Western blot and expression visualized by immunocytochemistry. Cytokine/chemokine production was measured by ELISA and Luminex, while rhPRG4's effect on MMP-9 activity, binding, and expression was quantified using an MMP-9 inhibitor kit, surface plasmon resonance, and reverse transcription polymerase chain reaction (RT-PCR), respectively. Finally, EDE was induced in mice, and PRG4 was visualized by immunohistochemistry in the cornea and by Western blot in lacrimal gland lysate. In vitro results demonstrate that hTCEpi cells synthesize and secrete PRG4, and PRG4 secretion is inhibited by TNFα and IL-1β. In response to these pro-inflammatory stresses, exogenous rhPRG4 significantly reduced the stimulated production of IP-10, RANTES, ENA-78, GROα, MIP-3α, and MIG, and trended towards a reduction of MIP-1α and MIP-1β. The hTCEpi cells were also able to internalize fluorescently-labelled rhPRG4, consistent with a mechanism of action that includes downstream biological signaling pathways. rhPRG4 was not digested by MMP-9, and it did not modulate MMP-9 gene expression in hTCEpi cells, but it was able to bind to MMP-9 and inhibited in vitro activity of exogenous MMP-9 in the presence of human tears. Finally, in vivo results demonstrate that EDE significantly decreased immunolocalization of PRG4 on the corneal epithelium and trended towards a reduction of PRG4 in lacrimal gland lysate. Collectively these results demonstrate rhPRG4 has anti-inflammatory properties on corneal epithelial cells, particularly as it relates to mitigating chemokine production, and is an inhibitor of MMP-9 activity, as well as that in vivo expression of PRG4 can be altered in preclinical models of DED. In conclusion, these findings contribute to our understanding of PRG4's immunomodulatory properties in the context of DED inflammation and provide the foundation and motivation for further mechanistic research of PRG4's properties on the ocular surface as well as expanding clinical evaluation of its ability as a multifunctional therapeutic agent to effectively provide relief to those who suffer from DED.
Collapse
Affiliation(s)
- Nikhil G Menon
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Ruchi Goyal
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Carolina Lema
- The Ocular Surface Institute, College of Optometry, University of Houston, Houston, TX, USA
| | - Paige S Woods
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Adam P Tanguay
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Alyssa A Morin
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Nabangshu Das
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | - Gregory D Jay
- Department of Emergency Medicine, Warren Alpert Medical School & School of Engineering, Brown University, Providence, RI, USA
| | - Roman J Krawetz
- Cell Biology and Anatomy, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| | - Antoine Dufour
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada; Physiology & Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Linda H Shapiro
- Department of Cell Biology, School of Medicine, UConn Health, Farmington, CT, USA
| | - Rachel L Redfern
- The Ocular Surface Institute, College of Optometry, University of Houston, Houston, TX, USA
| | - Mallika Ghosh
- Department of Cell Biology, School of Medicine, UConn Health, Farmington, CT, USA
| | - Tannin A Schmidt
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA.
| |
Collapse
|
7
|
Matheson A, Regmi SC, Jay GD, Schmidt TA, Scott WM. The Effect of Intense Exercise on Equine Serum Proteoglycan-4/Lubricin. Front Vet Sci 2020; 7:599287. [PMID: 33392293 PMCID: PMC7772952 DOI: 10.3389/fvets.2020.599287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 11/18/2020] [Indexed: 11/20/2022] Open
Abstract
Objective: Local biological and biomechanical-stimuli modulate proteoglycan-4 secretion within synovial joints. For the horse, changes to proteoglycan-4 concentration and function are notable in acute joint injury and osteoarthritis. Proteoglycan-4 (also known as Lubricin) is present in the blood, however the effect of exercise on equine serum levels is unknown. The overall objective of this study was, therefore, to investigate the effect of intense exercise on serum proteoglycan-4 in thoroughbred horses. Methods: Samples of blood were taken from thoroughbreds (n = 12) during a chuckwagon racing event (Alberta, Canada). The chuckwagon race is a sprint racing event where teams of horses pull a combined 1,325 lbs (601 kg) of wagon and driver around a 5/8th mile (1 km) of dirt track, racing at full gallop to the finish. Blood samples were collected 30-min before the race start, and several timepoints post-race: 5-min, 90-min, 3-h, 12-h, and 23-h. Proteoglycan-4 concentrations in serum were quantified by enzyme-linked-immunosorbent-assay using recombinant-human proteoglycan-4 standards and anti-proteoglycan-4 mAb 9G3. The molecular weight of immunoreactive proteoglycan-4 in serum was assessed by western blot. Results: Proteoglyan-4 in serum demonstrated the expected high MW immunoreactivity to mAb 9G3, consistent with that of full length PRG4. Serum proteoglycan-4 decreased five-minutes post-race from baseline concentration (0.815 ± 0.175 to 0.466 ± 0.090 μg/mL, μ ± SEM, p < 0.01). Conclusions: The concentration of serum proteoglycan-4 in horses decreased significantly five min post-exercise. A potential explanation for this finding could be increased proteoglycan-4 clearance from the circulation. Further investigations could extend to complete the detailed characterization of proteoglycan-4 structure and its potential function within the blood as it relates to joint health and exercise.
Collapse
Affiliation(s)
- Austyn Matheson
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | - Suresh C Regmi
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | - Gregory D Jay
- Department of Emergency Medicine, Warren Alpert Medical School & School of Engineering, Brown University, Providence, RI, United States
| | - Tannin A Schmidt
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, CT, United States
| | - W Michael Scott
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada.,Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
8
|
Serum Glycoproteomic Alterations in Patients with Diabetic Retinopathy. Proteomes 2020; 8:proteomes8030025. [PMID: 32933222 PMCID: PMC7565786 DOI: 10.3390/proteomes8030025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 09/09/2020] [Accepted: 09/09/2020] [Indexed: 12/19/2022] Open
Abstract
The precise molecular mechanisms of diabetic retinopathy (DR) pathogenesis are unclear, and treatment options are limited. There is an urgent need to discover and develop novel therapeutic targets for the treatment of this disease. Glycosylation is a post-translational modification that plays a critical role in determining protein structure, function, and stability. Recent studies have found that serum glycoproteomic changes are associated with the presence or progression of several inflammatory diseases. However, very little is known about the glycoproteomic changes associated with DR. In this study, glycoproteomic profiling of the serum of diabetic patients with and without DR was performed. A total of 15 glycopeptides from 11 glycoproteins were found to be significantly altered (5 upregulated and 10 downregulated) within the serum glycoproteome of DR patients. These glycoproteins are known to be involved in the maintenance of the extracellular matrix and complement system through peptidolytic activity or regulation.
Collapse
|
9
|
Ablation of the miRNA Cluster 24 Has Profound Effects on Extracellular Matrix Protein Abundance in Cartilage. Int J Mol Sci 2020; 21:ijms21114112. [PMID: 32526967 PMCID: PMC7312048 DOI: 10.3390/ijms21114112] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 05/28/2020] [Accepted: 06/02/2020] [Indexed: 12/17/2022] Open
Abstract
MicroRNAs (miRNAs) regulate cartilage differentiation and contribute to the onset and progression of joint degeneration. These small RNA molecules may affect extracellular matrix organization (ECM) in cartilage, but for only a few miRNAs has this role been defined in vivo. Previously, we showed that cartilage-specific genetic ablation of the Mirc24 cluster in mice leads to impaired cartilage development due to increased RAF/MEK/ERK pathway activation. Here, we studied the expression of the cluster in cartilage by LacZ reporter gene assays and determined its role for extracellular matrix homeostasis by proteome and immunoblot analysis. The cluster is expressed in prehypertrophic/hypertrophic chondrocytes of the growth plate and we now show that the cluster is also highly expressed in articular cartilage. Cartilage-specific loss of the cluster leads to increased proteoglycan 4 and matrix metallopeptidase 13 levels and decreased aggrecan and collagen X levels in epiphyseal cartilage. Interestingly, these changes are linked to a decrease in SRY-related HMG box-containing (SOX) transcription factors 6 and 9, which regulate ECM production in chondrocytes. Our data suggests that the Mirc24 cluster is important for ECM homoeostasis and the expression of transcriptional regulators of matrix production in cartilage.
Collapse
|
10
|
Kobler JB, Tynan MA, Zeitels SM, Liss AS, Gianatasio MT, Morin AA, Schmidt TA. Lubricin/proteoglycan 4 detected in vocal folds of humans and five other mammals. Laryngoscope 2019; 129:E229-E237. [PMID: 30613972 DOI: 10.1002/lary.27783] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/10/2018] [Indexed: 12/28/2022]
Abstract
OBJECTIVES/HYPOTHESIS Lubricin/proteoglycan-4 (PRG4) lubricates connective tissues such as joints and tendon sheaths, enabling them to better withstand shearing and frictional forces during motion. We wondered whether PRG4 might play a role in phonation, as normal vocal folds withstand repetitive, high-velocity deformations remarkably well. As a first step, we tested whether PRG4 is expressed in vocal folds. STUDY DESIGN Laboratory study. METHODS Anatomical and molecular methods were applied to 47 larynges from humans, macaque (Macaca fascicularis), canines, pigs, calves, and rats. Immunohistochemistry (IHC), Western blot, and quantitative real-time polymerase chain reaction (qRT-PCR) methods were used to test for the presence of PRG4. RESULTS In all species, the true vocal fold lamina propria (TVF-LP) was positive for PRG4 by IHC, whereas immunoreactivity of the false vocal fold was weak or absent, depending on the species. Human TVF-LP was strongly stained across all layers. Immunoreactivity was seen variably on the vocal fold surface and within the vocal fold epithelium, in the conus elasticus and thyroglottic ligament, and at the tip of vocal process. Western blots of four humans and six pigs demonstrated immunoreactivity at appropriate molecular weight. qRT-PCR of pig tissues confirmed PRG4 mRNA expression, which was highest in the TVF-LP. CONCLUSIONS PRG4 was found in phonatory tissues of six mammals. We suggest it might act as a lubricant within the lamina propria and possibly on the vocal fold surface, limiting phonation-related damage to vocal fold extracellular matrix and epithelium, and enhancing vocal efficiency by reducing internal friction (viscosity) within the vocal fold. LEVEL OF EVIDENCE NA Laryngoscope, 129:E229-E237, 2019.
Collapse
Affiliation(s)
- James B Kobler
- Center for Laryngeal Surgery and Voice Rehabilitation, Massachusetts General Hospital, Boston, Massachusetts, U.S.A.,Department of Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Monica A Tynan
- Center for Laryngeal Surgery and Voice Rehabilitation, Massachusetts General Hospital, Boston, Massachusetts, U.S.A
| | - Steven M Zeitels
- Center for Laryngeal Surgery and Voice Rehabilitation, Massachusetts General Hospital, Boston, Massachusetts, U.S.A.,Department of Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Andrew S Liss
- Center for Laryngeal Surgery and Voice Rehabilitation, Massachusetts General Hospital, Boston, Massachusetts, U.S.A.,Department of Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Maria T Gianatasio
- Cancer Center Histopathology Core, Massachusetts General Hospital, Boston, Massachusetts, U.S.A
| | - Alyssa A Morin
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, Connecticut, U.S.A
| | - Tannin A Schmidt
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, Connecticut, U.S.A
| |
Collapse
|
11
|
Das N, Schmidt TA, Krawetz RJ, Dufour A. Proteoglycan 4: From Mere Lubricant to Regulator of Tissue Homeostasis and Inflammation. Bioessays 2018; 41:e1800166. [DOI: 10.1002/bies.201800166] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Revised: 10/19/2018] [Indexed: 12/14/2022]
Affiliation(s)
- Nabangshu Das
- Faculty of Kinesiology; University of Calgary; Calgary Alberta T2N4N1 Canada
| | - Tannin A. Schmidt
- Biomedical Engineering Department; School of Dental Medicine; University of Connecticut Health Center; Farmington CT 06030 USA
| | - Roman J. Krawetz
- Cell Biology and Anatomy; Cumming School of Medicine; University of Calgary; 3330 Hospital Drive NW Calgary Alberta T2N4N1 Canada
- McCaig institute for Bone and Joint Health; University of Calgary; Calgary Alberta T2N4N1 Canada
| | - Antoine Dufour
- McCaig institute for Bone and Joint Health; University of Calgary; Calgary Alberta T2N4N1 Canada
- Physiology & Pharmacology; Cumming School of Medicine; University of Calgary; Calgary Alberta T2N4N1 Canada
| |
Collapse
|
12
|
Abubacker S, McPeak A, Dorosz SG, Egberts P, Schmidt TA. Effect of counterface on cartilage boundary lubricating ability by proteoglycan 4 and hyaluronan: Cartilage-glass versus cartilage-cartilage. J Orthop Res 2018; 36:2923-2931. [PMID: 29978918 DOI: 10.1002/jor.24104] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Accepted: 07/01/2018] [Indexed: 02/04/2023]
Abstract
The objective of this study was to determine the effect of different sliding interface materials (counterface) on the cartilage lubricating ability of proteoglycan 4 (PRG4) and hyaluronan (HA) by measuring the kinetic coefficient of friction on cartilage-glass and cartilage-cartilage interfaces over a wide range of sliding velocities. The lubrication properties of PRG4 and HA were assessed at cartilage-glass and cartilage-cartilage interfaces using a previously described test setup with a stationary area of contact. Samples were articulated at varying effective sliding velocities of 10, 3, 1, 0.3, 0.1, and 0.01 mm/s. The response of PRG4 and HA as effective friction-reducing cartilage boundary lubricants was varied and was dependent primarily on the test counterface. At a physiological cartilage-cartilage interface both HA and PRG4 effectively reduced friction compared to PBS at slower speeds while at higher speeds PRG4 was similar to PBS, and HA similar to SF. Conversely, at a cartilage-glass interface HA demonstrated no friction reducing ability compared to PBS, and PRG4 appeared just as effective as SF. Cartilage-glass friction coefficients were also significantly greater than cartilage-cartilage friction coefficients. These results indicate the in vitro friction coefficient of putative cartilage boundary lubricants can be affected by the test counterface and suggest that use of synthetic surfaces in studying cartilage boundary lubrication may not always be appropriate for all molecules of interest. As such, care should be taken when interpreting such data, specifically when comparing to in vitro data obtained at a cartilage-cartilage interface, and especially when extrapolating to in vivo situations. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2923-2931, 2018.
Collapse
Affiliation(s)
- Saleem Abubacker
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, Alberta, Canada
| | - Allison McPeak
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| | - Sam G Dorosz
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, Alberta, Canada
| | - Philip Egberts
- Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada
| | - Tannin A Schmidt
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, Alberta, Canada.,Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
13
|
Park DS, Regmi SC, Svystonyuk DA, Teng G, Belke D, Turnbull J, Guzzardi DG, Kang S, Cowman MK, Schmidt TA, Fedak PW. Human pericardial proteoglycan 4 (lubricin): Implications for postcardiotomy intrathoracic adhesion formation. J Thorac Cardiovasc Surg 2018; 156:1598-1608.e1. [DOI: 10.1016/j.jtcvs.2018.03.170] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 03/30/2018] [Accepted: 03/30/2018] [Indexed: 12/14/2022]
|
14
|
Parreno J, Bianchi VJ, Sermer C, Regmi SC, Backstein D, Schmidt TA, Kandel RA. Adherent agarose mold cultures: An in vitro platform for multi-factorial assessment of passaged chondrocyte redifferentiation. J Orthop Res 2018; 36:2392-2405. [PMID: 29575101 DOI: 10.1002/jor.23896] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Accepted: 03/14/2018] [Indexed: 02/04/2023]
Abstract
Generating the best possible bioengineered cartilage from passaged chondrocytes requires culture condition optimization. In this study, the use of adherent agarose mold (adAM) cultures to support redifferentiation of passaged twice (P2) chondrocytes and serve as a scalable platform to assess the effect of growth factor combinations on proteoglycan accumulation by cells was examined. By 2 days in adAM culture, bovine P2 cells were partially redifferentiated as demonstrated by regression of actin-based dedifferentiation signalling and fibroblast matrix and contractile gene expression. By day 10, aggrecan and type II collagen gene expression were significantly increased in adAM cultured cells. At day 20, a continuous layer of cartilage tissue was observed. There was no evidence of tissue contraction by P2 cells in adAM cultures. The matrix properties of the resultant tissue as well as proteoglycan 4 (PRG4) secreted by the cells were dependent on the initial cell seeding density. AdAM cultures were scalable and culture within small 3 mm diameter adAM allowed for multi-factorial assessment of growth factors on proteoglycan accumulation by human P2 chondrocytes. Although there was a patient specific response in proteoglycan accumulation to the various cocktail combinations, the cocktail consisting of 2 ng/ml TGFβ1, 10 ng/ml FGF2, and 250 ng/ml FGF18 resulted in a consistent increase in alcian blue tissue staining. Additional studies will be required to identify the optimal conditions to bioengineer articular cartilage tissue for clinical use. However, the results to date suggest that adAM cultures may be suitable to use for high throughput assessment. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2392-2405, 2018.
Collapse
Affiliation(s)
- Justin Parreno
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada.,Department of Molecular Medicine, The Scripps Research Institute, La Jolla, California
| | - Vanessa J Bianchi
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Corey Sermer
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada
| | - Suresh C Regmi
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | - David Backstein
- Division of Orthopaedics, Mount Sinai Hospital, Toronto, ON, Canada
| | - Tannin A Schmidt
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, Connecticut
| | - Rita A Kandel
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada.,Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada.,Pathology and Laboratory Medicine, Mount Sinai Hospital, Toronto, ON, Canada
| |
Collapse
|
15
|
Quantification of cartilage wear morphologies in unidirectional sliding experiments: Influence of different macromolecular lubricants. ACTA ACUST UNITED AC 2017. [DOI: 10.1016/j.biotri.2017.06.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
16
|
Degradation of proteoglycan 4/lubricin by cathepsin S: Potential mechanism for diminished ocular surface lubrication in Sjögren's syndrome. Exp Eye Res 2017; 161:1-9. [DOI: 10.1016/j.exer.2017.05.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Revised: 04/21/2017] [Accepted: 05/19/2017] [Indexed: 11/15/2022]
|
17
|
Samsom M, Iwabuchi Y, Sheardown H, Schmidt TA. Proteoglycan 4 and hyaluronan as boundary lubricants for model contact lens hydrogels. J Biomed Mater Res B Appl Biomater 2017; 106:1329-1338. [DOI: 10.1002/jbm.b.33895] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Revised: 03/07/2017] [Accepted: 03/28/2017] [Indexed: 11/12/2022]
Affiliation(s)
- Michael Samsom
- Biomedical Engineering Graduate ProgramUniversity of CalgaryCalgary AB Canada
| | - Yuno Iwabuchi
- Faculty of KinesiologyUniversity of CalgaryCalgary AB Canada
| | - Heather Sheardown
- Department of Chemical EngineeringMcMaster UniversityHamilton ON Canada
| | - Tannin A. Schmidt
- Biomedical Engineering Graduate ProgramUniversity of CalgaryCalgary AB Canada
- Faculty of KinesiologyUniversity of CalgaryCalgary AB Canada
| |
Collapse
|
18
|
Majd SE, Rizqy AI, Kaper HJ, Schmidt TA, Kuijer R, Sharma PK. An in vitro study of cartilage-meniscus tribology to understand the changes caused by a meniscus implant. Colloids Surf B Biointerfaces 2017; 155:294-303. [PMID: 28437755 DOI: 10.1016/j.colsurfb.2017.04.034] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2016] [Revised: 04/12/2017] [Accepted: 04/13/2017] [Indexed: 10/19/2022]
Abstract
Active lifestyles increase the risk of meniscal injury. A permanent meniscus implant of polycarbonate urethane (PCU) is a promising treatment to postpone/prevent total knee arthroplasty. Study of the changes in articular cartilage tribology in the presence of PCU is essential in developing the optimum meniscus implant. Therefore, a cartilage-meniscus reciprocating, sliding model was developed in vitro, mimicking the stance and swing phases of the gait cycle. The meniscus was further replaced with PCU and surface-modified PCUs (with C18 chains, mono-functional polydimethylsiloxane groups and mono-functional polytetrafluoroethylene groups) to study the changes. The coefficient of friction (COF) was calculated, and cartilage wear was determined and quantified histologically. The cartilage-meniscus sliding resulted in low COF during both stance and swing (0.01< COF <0.12) and low wear of cartilage (scores <1). The cartilage-PCU sliding, during stance, revealed similar low COFs. But during swing, the COFs were high (average ∼1, maximum 1.6), indicating a breakdown in interstitial fluid pressurization lubrication and non-effective activation of the boundary lubrication. This may lead to wear of cartilage in long term. However, under the tested conditions the wear of cartilage against PCUs was not higher than its wear against meniscus, and the cartilage was occasionally damaged. The COF decreased with increasing the contact pressure (as-per a power equation) up to 1MPa. The changes in the surface modification of PCU did not affect PCU's tribological performance.
Collapse
Affiliation(s)
- Sara Ehsani Majd
- University of Groningen, University Medical Centre Groningen, Department of Biomedical Engineering, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands
| | - Aditya Iman Rizqy
- University of Groningen, University Medical Centre Groningen, Department of Biomedical Engineering, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands
| | - Hans J Kaper
- University of Groningen, University Medical Centre Groningen, Department of Biomedical Engineering, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands
| | - Tannin A Schmidt
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | - Roel Kuijer
- University of Groningen, University Medical Centre Groningen, Department of Biomedical Engineering, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands
| | - Prashant K Sharma
- University of Groningen, University Medical Centre Groningen, Department of Biomedical Engineering, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands.
| |
Collapse
|
19
|
Abubacker S, Ponjevic D, Ham HO, Messersmith PB, Matyas JR, Schmidt TA. Effect of disulfide bonding and multimerization on proteoglycan 4's cartilage boundary lubricating ability and adsorption. Connect Tissue Res 2016; 57:113-23. [PMID: 26631309 PMCID: PMC4857611 DOI: 10.3109/03008207.2015.1113271] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE The objectives of this study were to assess the cartilage boundary lubricating ability of (1) nonreduced (NR) disulfide-bonded proteoglycan 4 (PRG4) multimers versus PRG4 monomers and (2) NR versus reduced and alkylated (R/A) PRG4 monomers and to assess (3) the ability of NR PRG4 multimers versus monomers to adsorb to an articular cartilage surface. MATERIALS AND METHODS PRG4 was separated into two preparations, PRG4 multimer enriched (PRG4Multi+) and PRG4 multimer deficient (PRG4Multi-), using size exclusion chromatography (SEC) and characterized by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). The cartilage boundary lubricating ability of PRG4Multi+ and PRG4Multi- was compared at a physiological concentration (450 μg/mL) and assessed over a range of concentrations (45, 150, and 450 μg/mL). R/A and NR PRG4Multi- were evaluated at 450 μg/mL. Immunohistochemistry with anti-PRG4 antibody 4D6 was performed to visualize the adsorption of PRG4 preparations to the surface of articular cartilage explants. RESULTS Separation into enriched populations of PRG4Multi+ and PRG4Multi- was achieved using SEC and was confirmed by SDS-PAGE. PRG4Multi+ and PRG4Multi- both functioned as effective friction-reducing cartilage boundary lubricants at 450 μg/mL, with PRG4Multi+ being more effective than PRG4Multi-. PRG4Multi+ lubricated in a dose-dependent manner, however, PRG4Multi- did not. R/A PRG4Multi- lubricated similar to NR PRG4Multi-. PRG4-containing solutions showed 4D6 immunoreactivity at the articular surface; the immunoreactive intensity of PRG4Multi+ appeared to be similar to SF, whereas PRG4Multi- appeared to have less intensity. CONCLUSIONS These results demonstrate that the intermolecular disulfide-bonded multimeric structure of PRG4 is important for its ability to adsorb to a cartilage surface and function as a boundary lubricant. These findings contribute to a greater understanding of the molecular basis of cartilage boundary lubrication of PRG4. Elucidating the PRG4 structure-lubrication function relationship will further contribute to the understanding of PRG4's role in diarthrodial joint homeostasis and disease.
Collapse
Affiliation(s)
- Saleem Abubacker
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada.,McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| | - Dragana Ponjevic
- McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada.,Department of Comparative Biology and Experimental Medicine, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| | - Hyun O. Ham
- Biomedical Engineering Department, Northwestern University, Evanston, IL, USA
| | - Phillip B. Messersmith
- Biomedical Engineering Department, Northwestern University, Evanston, IL, USA.,Departments of Bioengineering and Materials Science and Engineering Department, University of California, Berkeley, CA, USA
| | - John R. Matyas
- McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada.,Department of Comparative Biology and Experimental Medicine, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| | - Tannin A. Schmidt
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada.,McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada.,Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
20
|
Ludwig TE, Hunter MM, Schmidt TA. Cartilage boundary lubrication synergism is mediated by hyaluronan concentration and PRG4 concentration and structure. BMC Musculoskelet Disord 2015; 16:386. [PMID: 26666513 PMCID: PMC4678696 DOI: 10.1186/s12891-015-0842-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2014] [Accepted: 12/02/2015] [Indexed: 11/26/2022] Open
Abstract
Background Proteoglycan 4 (PRG4) and hyaluronan (HA) are key synovial fluid constituents that contribute synergistically to cartilage boundary lubrication; however, the effects of their concentrations as well as their structure, both of which can be altered in osteoarthritis, on this functional synergism are unknown. The objectives of this study were to evaluate cartilage boundary lubricating ability of 1) PRG4 + HA in solution at constant HA concentration in a range of PRG4 concentrations, 2) constant PRG4 concentration in a range of HA concentrations, 3) HA + reduced/alkylated (R/A) PRG4, and 4) hylan G-F 20 + PRG4. Methods Static and kinetic friction coefficients (μstatic,Neq, <μkinetic,Neq>) were measured using a previously characterized cartilage-cartilage boundary mode friction test for the following concentrations of purified PRG4 and HA: Test 1: HA (1.5 MDa, 3.3 mg/mL) + PRG4 from 4.5 – 1500 μg/mL; Test 2: PRG4 (450, 150, 45 μg/mL) + HA (1.5 MDa) from 0.3 – 3.3 mg/mL. Test 3: hylan G-F 20 (3. 3 mg/mL) + PRG4 (450 μg/mL). Test 4: HA (3.3 mg/mL) + R/A PRG4 (450 μg/mL). ANOVA was used to compare lubricants within (comparing 6 lubricants of interest) and between (comparing 3 lubricants of interest) test sequences, with Tukey and Fishers post-hoc testing respectively. Results This study demonstrates that both PRG4 and HA concentration, as well as PRG4 disulfide-bonded structure, can alter the cartilage boundary lubricating ability of PRG4 + HA solutions. The boundary lubricating ability of high MW HA + PRG4 solutions was limited by very low concentrations of PRG4. Decreased concentrations of high MW HA also limited the cartilage boundary lubricating ability of HA + PRG4 solutions, with the effect exacerbated by low PRG4 concentrations. The reduction of friction by addition of PRG4 to a cross-linked HA viscosupplement product, but not with addition of R/A PRG4 to HA, is consistent with a non-covalent mechanism of interaction where tertiary and quaternary PRG4 structure are important. Conclusions Collectively, these results demonstrate that deficiency of either or both PRG4 and HA, or alterations in PRG4 structure, may be detrimental to SF cartilage boundary lubricating function. This study provides further insight into the nature of cartilage boundary lubrication and advancement towards potential formulation of new intra-articular biotherapeutic treatments for osteoarthritis using PRG4 ± HA.
Collapse
Affiliation(s)
- Taryn E Ludwig
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, Canada.
| | - Miles M Hunter
- Faculty of Kinesiology, University of Calgary, Calgary, Canada.
| | - Tannin A Schmidt
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, Canada. .,Faculty of Kinesiology, University of Calgary, Calgary, Canada.
| |
Collapse
|
21
|
Abubacker S, Dorosz SG, Ponjevic D, Jay GD, Matyas JR, Schmidt TA. Full-Length Recombinant Human Proteoglycan 4 Interacts with Hyaluronan to Provide Cartilage Boundary Lubrication. Ann Biomed Eng 2015; 44:1128-37. [PMID: 26194040 DOI: 10.1007/s10439-015-1390-8] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2015] [Accepted: 07/11/2015] [Indexed: 11/28/2022]
Abstract
Proteoglycan 4 (PRG4) is a mucin-like glycoprotein present in synovial fluid and at the surface of articular cartilage. The objectives of this study were to (1) assess the articular cartilage surface adsorption and in vitro cartilage boundary lubricating ability of full-length recombinant human PRG4 (rhPRG4), and (2) cartilage boundary lubricating ability of purified rhPRG4, both alone and in combination with hyaluronan (HA). rhPRG4 adsorption onto articular cartilage explants was assessed by immunohistochemistry and dot blot. An in vitro cartilage-cartilage friction test was used to assess rhPRG4's cartilage boundary lubricating ability compared to bovine PRG4, and that of purified rhPRG4 both alone and in combination with HA. rhPRG4 was able to adsorb to the articular surface, as well as the cut surface, of cartilage explants. The kinetic coefficient of friction of rhPRG4 was similar to that of PRG4 (p = 0.16) and lower than phosphate-buffered saline (p < 0.05), while that of purified rhPRG4 + HA was significantly lower than rhPRG4 alone (p < 0.05). This study demonstrates that rhPRG4 can adsorb to an intact articular cartilage surface and functions as an effective boundary lubricant, both alone and with HA, and provides the foundation for in vivo evaluation of this clinically relevant full-length rhPRG4 for treatment of osteoarthritis.
Collapse
Affiliation(s)
- Saleem Abubacker
- Biomedical Engineering Graduate Program, University of Calgary, 2500 University Dr NW, KNB 426, Calgary, AB, T2N 1N4, Canada.,McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| | - Samuel G Dorosz
- Biomedical Engineering Graduate Program, University of Calgary, 2500 University Dr NW, KNB 426, Calgary, AB, T2N 1N4, Canada.,McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| | - Dragana Ponjevic
- McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada.,Department of Comparative Biology and Experimental Medicine, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| | - Gregory D Jay
- Center for Biomedical Engineering and the School of Engineering, Brown University, Providence, RI, USA
| | - John R Matyas
- McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada.,Department of Comparative Biology and Experimental Medicine, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| | - Tannin A Schmidt
- Biomedical Engineering Graduate Program, University of Calgary, 2500 University Dr NW, KNB 426, Calgary, AB, T2N 1N4, Canada. .,McCaig Institute of Bone and Joint Health, University of Calgary, Calgary, AB, Canada. .,Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada.
| |
Collapse
|
22
|
Ai M, Cui Y, Sy MS, Lee DM, Zhang LX, Larson KM, Kurek KC, Jay GD, Warman ML. Anti-lubricin monoclonal antibodies created using lubricin-knockout mice immunodetect lubricin in several species and in patients with healthy and diseased joints. PLoS One 2015; 10:e0116237. [PMID: 25642942 PMCID: PMC4314068 DOI: 10.1371/journal.pone.0116237] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Accepted: 12/06/2014] [Indexed: 11/18/2022] Open
Abstract
Lubricin, encoded by the gene PRG4, is the principal lubricant in articulating joints. We immunized mice genetically deficient for lubricin (Prg4-/-) with purified human lubricin, and generated several mAbs. We determined each mAb’s binding epitope, sensitivity, and specificity using biologic samples and recombinant lubricin sub-domains, and we also developed a competition ELISA assay to measure lubricin in synovial fluid and blood. We found the mAbs all recognized epitopes containing O-linked oligosaccharides conjugated to the peptide motif KEPAPTTT. By western blot, the mAbs detected lubricin in 1 μl of synovial fluid from several animal species, including human. The mAbs were specific for lubricin since they did not cross-react with other synovial fluid constituents from patients with camptodactyly-arthropathy-coxa vara-pericarditis syndrome (CACP), who genetically lack this protein. The competition ELISA detected lubricin in blood samples from healthy individuals but not from patients with CACP, indicating blood can be used in a diagnostic test for patients suspected of having CACP. Lubricin epitopes in blood do not represent degradation fragments from synovial fluid. Therefore, although blood lubricin levels did not differentiate patients with inflammatory joint disease from healthy controls, epitope-specific anti-lubricin mAbs could be useful for monitoring disease activity in synovial fluid.
Collapse
Affiliation(s)
- Minrong Ai
- Howard Hughes Medical Institute and Department of Genetics, Case Western Reserve University, School of Medicine, Cleveland, OH, United States of America
| | - Yajun Cui
- Howard Hughes Medical Institute and Department of Genetics, Case Western Reserve University, School of Medicine, Cleveland, OH, United States of America
| | - Man-Sun Sy
- Department of Pathology, Case Western Reserve University, School of Medicine, Cleveland, OH, United States of America
| | - David M Lee
- Division of Rheumatology, Immunology and Allergy, Brigham and Women's Hospital, Boston, MA, United States of America
| | - Ling Xiu Zhang
- Department of Emergency Medicine, Rhode Island Hospital, Providence, RI, United States of America
| | - Katherine M Larson
- Department of Emergency Medicine, Rhode Island Hospital, Providence, RI, United States of America; School of Engineering, Brown University, Providence, RI, United States of America
| | - Kyle C Kurek
- Department of Pathology, Boston Children's Hospital, Boston, MA, United States of America
| | - Gregory D Jay
- Department of Emergency Medicine, Rhode Island Hospital, Providence, RI, United States of America; School of Engineering, Brown University, Providence, RI, United States of America
| | - Matthew L Warman
- Howard Hughes Medical Institute and Department of Genetics, Case Western Reserve University, School of Medicine, Cleveland, OH, United States of America; Howard Hughes Medical Institute and Orthopaedics Research Laboratories, Boston Children's Hospital, and Departments of Genetics and Orthopaedic Surgery, Harvard Medical School, Boston, MA, United States of America
| |
Collapse
|
23
|
Majd SE, Kuijer R, Köwitsch A, Groth T, Schmidt TA, Sharma PK. Both hyaluronan and collagen type II keep proteoglycan 4 (lubricin) at the cartilage surface in a condition that provides low friction during boundary lubrication. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:14566-72. [PMID: 25409034 DOI: 10.1021/la504345c] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Wear resistant and ultralow friction in synovial joints is the outcome of a sophisticated synergy between the major macromolecules of the synovial fluid, e.g., hyaluronan (HA) and proteoglycan 4 (PRG4), with collagen type II fibrils and other non-collagenous macromolecules of the cartilage superficial zone (SZ). This study aimed at better understanding the mechanism of PRG4 localization at the cartilage surface. We show direct interactions between surface bound HA and freely floating PRG4 using the quartz crystal microbalance with dissipation (QCM-D). Freely floating PRG4 was also shown to bind with surface bound collagen type II fibrils. Albumin, the most abundant protein of the synovial fluid, effectively blocked the adsorption of PRG4 with HA, through interaction with C and N terminals on PRG4, but not that of PRG4 with collagen type II fibrils. The above results indicate that collagen type II fibrils strongly contribute in keeping PRG4 in the SZ during cartilage articulation in situ. Furthermore, PRG4 molecules adsorbed very well on mimicked SZ of absorbed HA molecules with entangled collagen type II fibrils and albumin was not able to block this interaction. In this last condition PRG4 adsorption resulted in a coefficient of friction (COF) of the same order of magnitude as the COF of natural cartilage, measured with an atomic force microscope in lateral mode.
Collapse
Affiliation(s)
- Sara Ehsani Majd
- Department of Biomedical Engineering, University of Groningen, University Medical Centre Groningen , Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands
| | | | | | | | | | | |
Collapse
|
24
|
Grissom MJ, Temple-Wong MM, Adams MS, Tom M, Schumacher BL, McIlwraith CW, Goodrich LR, Chu CR, Sah RL. Synovial Fluid Lubricant Properties are Transiently Deficient after Arthroscopic Articular Cartilage Defect Repair with Platelet-Enriched Fibrin Alone and with Mesenchymal Stem Cells. Orthop J Sports Med 2014; 2. [PMID: 25530978 PMCID: PMC4267539 DOI: 10.1177/2325967114542580] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Following various types of naturally-occurring traumatic injury to an articular joint, the lubricating ability of synovial fluid is impaired, with a correlated alteration in the concentration and/or structure of lubricant molecules, hyaluronan and proteoglycan-4. However, the effect of arthroscopic cartilage repair surgery on synovial fluid lubricant function and composition is unknown. HYPOTHESIS Arthroscopic treatment of full-thickness chondral defects in horses with (1) platelet-enriched fibrin or (2) platelet-enriched fibrin+mesenchymal stem cells leads to equine synovial fluid with impaired lubricant function and hyaluronan and proteoglycan-4 composition. STUDY DESIGN Controlled Laboratory Study. METHODS Equine synovial fluid was aspirated from normal joints at a pre-injury state (0 days) and at 10 days and 3 months following fibrin or fibrin+mesenchymal stem cell repair of full thickness chondral defects. Equine synovial fluid samples were analyzed for friction-lowering boundary lubrication of normal articular cartilage (static and kinetic friction coefficients) and concentrations of hyaluronan and proteoglycan-4, as well as molecular weight distribution of hyaluronan. Experimental groups deficient in lubrication function were also tested for the ability of exogenous high-molecular weight hyaluronan to restore lubrication function. RESULTS Lubrication and biochemical data varied with time after surgery but generally not between repair groups. Relative to pre-injury, kinetic friction was higher (+94%) at 10 days but returned to baseline levels at 3 months while static friction was not altered. Correspondingly, hyaluronan concentration was transiently lower (-64%) and shifted towards lower molecular weight forms, while proteoglycan-4 concentration was increased (+210%) in 10-day samples relative to pre-injury levels. Regression analysis revealed that kinetic friction decreased with increasing total and high molecular weight hyaluronan. Addition of high molecular weight hyaluronan to bring 10-day hyaluronan levels to 2.0mg/ml restored kinetic friction to pre-injury levels. CONCLUSION Following arthroscopic surgery for cartilage defect repair, synovial fluid lubrication function is transiently impaired, in association with decreased hyaluronan concentration. This functional deficiency in synovial fluid lubrication can be counteracted in vitro by addition of high molecular weight hyaluronan. CLINICAL RELEVANCE Synovial fluid lubrication is deficient shortly following arthroscopic cartilage repair surgery, and supplementation with high molecular weight hyaluronan may be beneficial.
Collapse
Affiliation(s)
- Murray J Grissom
- Murray J. Grissom, MS, Michele M. Temple-Wong, PhD, Matthew S. Adams, BS, Matthew Tom, Barbara L. Schumacher, BS, Robert L. Sah, MD, ScD: University of California, San Diego, La Jolla
| | - Michele M Temple-Wong
- Murray J. Grissom, MS, Michele M. Temple-Wong, PhD, Matthew S. Adams, BS, Matthew Tom, Barbara L. Schumacher, BS, Robert L. Sah, MD, ScD: University of California, San Diego, La Jolla
| | - Matthew S Adams
- Murray J. Grissom, MS, Michele M. Temple-Wong, PhD, Matthew S. Adams, BS, Matthew Tom, Barbara L. Schumacher, BS, Robert L. Sah, MD, ScD: University of California, San Diego, La Jolla
| | - Matthew Tom
- Murray J. Grissom, MS, Michele M. Temple-Wong, PhD, Matthew S. Adams, BS, Matthew Tom, Barbara L. Schumacher, BS, Robert L. Sah, MD, ScD: University of California, San Diego, La Jolla
| | - Barbara L Schumacher
- Murray J. Grissom, MS, Michele M. Temple-Wong, PhD, Matthew S. Adams, BS, Matthew Tom, Barbara L. Schumacher, BS, Robert L. Sah, MD, ScD: University of California, San Diego, La Jolla
| | - C Wayne McIlwraith
- C. Wayne McIlwraith, DVM, PhD, Laurie R Goodrich, DVM, PhD: Colorado State University, Fort Collins, Colorado
| | - Laurie R Goodrich
- C. Wayne McIlwraith, DVM, PhD, Laurie R Goodrich, DVM, PhD: Colorado State University, Fort Collins, Colorado
| | - Constance R Chu
- Constance R. Chu, MD: Stanford University School of Medicine, Stanford, California
| | - Robert L Sah
- Murray J. Grissom, MS, Michele M. Temple-Wong, PhD, Matthew S. Adams, BS, Matthew Tom, Barbara L. Schumacher, BS, Robert L. Sah, MD, ScD: University of California, San Diego, La Jolla
| |
Collapse
|
25
|
Samsom ML, Morrison S, Masala N, Sullivan BD, Sullivan DA, Sheardown H, Schmidt TA. Characterization of full-length recombinant human Proteoglycan 4 as an ocular surface boundary lubricant. Exp Eye Res 2014; 127:14-9. [PMID: 24997456 DOI: 10.1016/j.exer.2014.06.015] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2014] [Revised: 06/11/2014] [Accepted: 06/20/2014] [Indexed: 11/15/2022]
Abstract
Proteoglycan 4 (PRG4, or lubricin) is a lubricating mucin-like glycoprotein recently discovered at the ocular surface, where it functions as a boundary lubricant and appears to play a protective role. Recent technological advances have enabled abundant expression of full-length recombinant human PRG4 (rhPRG4). The objectives of this study were to 1) biochemically characterize the gross structure and glycosylations of full-length rhPRG4, and 2) assess the ocular surface boundary lubricating ability of rhPRG4 at both human cornea-eyelid and human cornea-polydimethylsiloxane (PDMS) biointerfaces. rhPRG4 expressed by a Chinese hamster ovary cell line was characterized and compared to native bovine PRG4 by SDS-PAGE western blotting, and protein identity was assessed by tandem mass spectrometry (MS/MS). Human corneas were articulated against PDMS or human eyelids, at effective sliding velocities of 0.3-30 mm/s under physiological loads of ∼15 kPa, to assess and compare the ocular lubricating ability of rhPRG4 to PRG4. Samples were tested serially in PRG4, rhPRG4 (both 300 μg/ml), then saline. Western blotting indicated that rhPRG4 had immunoreactivity at the appropriate apparent molecular weight, and possessed O-linked glycosylation consistent with that of PRG4. rhPRG4 protein identity was confirmed by MS/MS. Both PRG4 and rhPRG4 significantly, and similarly, reduced friction compared to saline at both human cornea - PDMS and human cornea-eyelid biointerfaces. In conclusion, the rhPRG4 studied here demonstrated appropriate higher order structure, O-linked glycosylations, and ocular surface boundary lubricating. Purified rhPRG4 may have clinical utility as a topical treatment of dry eye disease or contact lens biomaterial coating to promote more comfortable wear.
Collapse
Affiliation(s)
- Michael L Samsom
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | - Sheila Morrison
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | - Nemanja Masala
- Schulich School of Engineering - Centre for Bioengineering Research & Education, University of Calgary, Calgary, AB, Canada
| | | | - David A Sullivan
- Schepens Eye Research Institute, Massachusetts Eye and Ear, USA; Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| | | | - Tannin A Schmidt
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada; Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada; Schulich School of Engineering - Centre for Bioengineering Research & Education, University of Calgary, Calgary, AB, Canada.
| |
Collapse
|
26
|
Optimization of unnicked β2-glycoprotein I and high avidity anti-β2-glycoprotein I antibodies isolation. J Immunol Res 2014; 2014:195687. [PMID: 24741579 PMCID: PMC3987788 DOI: 10.1155/2014/195687] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2013] [Accepted: 12/08/2013] [Indexed: 11/19/2022] Open
Abstract
Patient biological material for isolation of β2-glycoprotein I (β2GPI) and high avidity IgG anti-β2-glycoprotein I antibodies (HAv anti-β2GPI) dictates its full utilization. The aim of our study was to evaluate/improve procedures for isolation of unnicked β2GPI and HAv aβ2GPI to gain unmodified proteins in higher yields/purity. Isolation of β2GPI from plasma was a stepwise procedure combining nonspecific and specific methods. For isolation of polyclonal HAv aβ2GPI affinity chromatographies with immobilized protein G and human β2GPI were used. The unknown protein found during isolation was identified by liquid chromatography electrospray ionization mass spectrometry and the nonredundant National Center for Biotechnology Information database. The average mass of the isolated unnicked purified β2GPI increased from 6.56 mg to 9.94 mg. In the optimized isolation procedure the high molecular weight protein (proteoglycan 4) was successfully separated from β2GPI in the 1st peaks with size exclusion chromatography. The average efficiency of the isolation procedure for polyclonal HAv anti-β2GPI from different matrixes was 13.8%, as determined by our in-house anti-β2GPI ELISA. We modified the in-house isolation and purification procedures of unnicked β2GPI and HAv anti-β2GPI, improving the purity of antigen and antibodies as well as increasing the number of tests routinely performed with the in-house ELISA by ~50%.
Collapse
|
27
|
Schmidt TA, Sullivan DA, Knop E, Richards SM, Knop N, Liu S, Sahin A, Darabad RR, Morrison S, Kam WR, Sullivan BD. Transcription, translation, and function of lubricin, a boundary lubricant, at the ocular surface. JAMA Ophthalmol 2013; 131:766-76. [PMID: 23599181 DOI: 10.1001/jamaophthalmol.2013.2385] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
IMPORTANCE Lubricin may be an important barrier to the development of corneal and conjunctival epitheliopathies that may occur in dry eye disease and contact lens wear. OBJECTIVE To test the hypotheses that lubricin (ie, proteoglycan 4 [PRG4 ]), a boundary lubricant, is produced by ocular surface epithelia and acts to protect the cornea and conjunctiva against significant shear forces generated during an eyelid blink and that lubricin deficiency increases shear stress on the ocular surface and promotes corneal damage. DESIGN, SETTING, AND PARTICIPANTS Human, porcine, and mouse tissues and cells were processed for molecular biological, immunohistochemical, and tribological studies, and wild-type and PRG4 knockout mice were evaluated for corneal damage. RESULTS Our findings demonstrate that lubricin is transcribed and translated by corneal and conjunctival epithelial cells. Lubricin messenger RNA is also present in lacrimal and meibomian glands, as well as in a number of other tissues. Absence of lubricin in PRG4 knockout mice is associated with a significant increase in corneal fluorescein staining. Our studies also show that lubricin functions as an effective friction-lowering boundary lubricant at the human cornea-eyelid interface. This effect is specific and cannot be duplicated by the use of hyaluronate or bovine serum albumin solutions. CONCLUSIONS AND RELEVANCE Our results show that lubricin is transcribed, translated, and expressed by ocular surface epithelia. Moreover, our findings demonstrate that lubricin presence significantly reduces friction between the cornea and conjunctiva and that lubricin deficiency may play a role in promoting corneal damage.
Collapse
Affiliation(s)
- Tannin A Schmidt
- Faculty of Kinesiology, Human Performance Laboratory Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Abusara Z, Krawetz R, Steele B, DuVall M, Schmidt T, Herzog W. Muscular loading of joints triggers cellular secretion of PRG4 into the joint fluid. J Biomech 2013; 46:1225-30. [DOI: 10.1016/j.jbiomech.2013.02.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Revised: 02/27/2013] [Accepted: 02/28/2013] [Indexed: 10/27/2022]
|
29
|
Abubacker S, Ham HO, Messersmith PB, Schmidt TA. Cartilage boundary lubricating ability of aldehyde modified proteoglycan 4 (PRG4-CHO). Osteoarthritis Cartilage 2013; 21:186-9. [PMID: 23041437 PMCID: PMC3538920 DOI: 10.1016/j.joca.2012.09.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2012] [Revised: 09/19/2012] [Accepted: 09/24/2012] [Indexed: 02/02/2023]
Affiliation(s)
- Saleem Abubacker
- Biomedical Engineering, University of Calgary, Calgary, AB, Canada
| | - Hyun O. Ham
- Biomedical Engineering Department, Northwestern University, Evanston, IL, USA
| | | | - Tannin A. Schmidt
- Biomedical Engineering, University of Calgary, Calgary, AB, Canada
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| |
Collapse
|