1
|
B Wrammerfors ET, Törnquist E, Pierantoni M, Sjögren A, Tengattini A, Kaestner A, Zandt RI', Englund M, Isaksson H. Exploratory neutron tomography of articular cartilage. Osteoarthritis Cartilage 2024; 32:702-712. [PMID: 38447631 DOI: 10.1016/j.joca.2024.02.889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 02/28/2024] [Accepted: 02/28/2024] [Indexed: 03/08/2024]
Abstract
OBJECTIVE To investigate the feasibility of using neutron tomography to gain new knowledge of human articular cartilage degeneration in osteoarthritis (OA). Different sample preparation techniques were evaluated to identify maximum intra-tissue contrast. DESIGN Human articular cartilage samples from 14 deceased donors (18-75 years, 9 males, 5 females) and 4 patients undergoing total knee replacement due to known OA (all female, 61-75 years) were prepared using different techniques: control in saline, treated with heavy water saline, fixed and treated in heavy water saline, and fixed and dehydrated with ethanol. Neutron tomographic imaging (isotropic voxel sizes from 7.5 to 13.5 µm) was performed at two large scale facilities. The 3D images were evaluated for gradients in hydrogen attenuation as well as compared to images from absorption X-ray tomography, magnetic resonance imaging, and histology. RESULTS Cartilage was distinguishable from background and other tissues in neutron tomographs. Intra-tissue contrast was highest in heavy water-treated samples, which showed a clear gradient from the cartilage surface to the bone interface. Increased neutron flux or exposure time improved image quality but did not affect the ability to detect gradients. Samples from older donors showed high variation in gradient profile, especially from donors with known OA. CONCLUSIONS Neutron tomography is a viable technique for specialized studies of cartilage, particularly for quantifying properties relating to the hydrogen density of the tissue matrix or water movement in the tissue.
Collapse
Affiliation(s)
| | - Elin Törnquist
- Department of Biomedical Engineering, Lund University (LU), Sweden
| | - Maria Pierantoni
- Department of Biomedical Engineering, Lund University (LU), Sweden
| | - Amanda Sjögren
- Clinical Epidemiology Unit, Orthopedics, Department of Clinical Sciences Lund, LU, Sweden
| | | | - Anders Kaestner
- Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut (PSI), Switzerland
| | | | - Martin Englund
- Clinical Epidemiology Unit, Orthopedics, Department of Clinical Sciences Lund, LU, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University (LU), Sweden
| |
Collapse
|
2
|
Orellana F, Grassi A, Hlushchuk R, Wahl P, Nuss KM, Neels A, Zaffagnini S, Parrilli A. Revealing the complexity of meniscus microvasculature through 3D visualization and analysis. Sci Rep 2024; 14:10875. [PMID: 38740845 DOI: 10.1038/s41598-024-61497-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 05/07/2024] [Indexed: 05/16/2024] Open
Abstract
Three-dimensional information is essential for a proper understanding of the healing potential of the menisci and their overall role in the knee joint. However, to date, the study of meniscal vascularity has relied primarily on two-dimensional imaging techniques. Here we present a method to elucidate the intricate 3D meniscal vascular network, revealing its spatial arrangement, connectivity and density. A polymerizing contrast agent was injected into the femoral artery of human cadaver legs, and the meniscal microvasculature was examined using micro-computed tomography at different levels of detail and resolution. The 3D vascular network was quantitatively assessed in a zone-base analysis using parameters such as diameter, length, tortuosity, and branching patterns. The results of this study revealed distinct vascular patterns within the meniscus, with the highest vascular volume found in the outer perimeniscal zone. Variations in vascular parameters were found between the different circumferential and radial meniscal zones. Moreover, through state-of-the-art 3D visualization using micro-CT, this study highlighted the importance of spatial resolution in accurately characterizing the vascular network. These findings, both from this study and from future research using this technique, improve our understanding of microvascular distribution, which may lead to improved therapeutic strategies.
Collapse
Affiliation(s)
- Federica Orellana
- Center for X-Ray Analytics, Empa-Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland
- Department of Chemistry, University of Fribourg, 1700, Fribourg, Switzerland
| | - Alberto Grassi
- IRCCS-Rizzoli Orthopaedic Institute, 40136, Bologna, Italy
| | - Ruslan Hlushchuk
- Faculty of Medicine, University of Bern, 3012, Bern, Switzerland
| | - Peter Wahl
- Faculty of Medicine, University of Bern, 3012, Bern, Switzerland
- Cantonal Hospital Winterthur, 8401, Winterthur, Switzerland
| | - Katja M Nuss
- Vetsuisse Faculty, University of Zurich, 8057, Zurich, Switzerland
| | - Antonia Neels
- Center for X-Ray Analytics, Empa-Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland
- Department of Chemistry, University of Fribourg, 1700, Fribourg, Switzerland
| | | | - Annapaola Parrilli
- Center for X-Ray Analytics, Empa-Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland.
| |
Collapse
|
3
|
Dejea H, Pierantoni M, Orozco GA, B Wrammerfors ET, Gstöhl SJ, Schlepütz CM, Isaksson H. In Situ Loading and Time-Resolved Synchrotron-Based Phase Contrast Tomography for the Mechanical Investigation of Connective Knee Tissues: A Proof-of-Concept Study. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2308811. [PMID: 38520713 DOI: 10.1002/advs.202308811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 02/26/2024] [Indexed: 03/25/2024]
Abstract
Articular cartilage and meniscus transfer and distribute mechanical loads in the knee joint. Degeneration of these connective tissues occurs during the progression of knee osteoarthritis, which affects their composition, microstructure, and mechanical properties. A deeper understanding of disease progression can be obtained by studying them simultaneously. Time-resolved synchrotron-based X-ray phase-contrast tomography (SR-PhC-µCT) allows to capture the tissue dynamics. This proof-of-concept study presents a rheometer setup for simultaneous in situ unconfined compression and SR-PhC-µCT of connective knee tissues. The microstructural response of bovine cartilage (n = 16) and meniscus (n = 4) samples under axial continuously increased strain, or two steps of 15% strain (stress-relaxation) is studied. The chondrocyte distribution in cartilage and the collagen fiber orientation in the meniscus are assessed. Variations in chondrocyte density reveal an increase in the top 40% of the sample during loading, compared to the lower half. Meniscus collagen fibers reorient perpendicular to the loading direction during compression and partially redisperse during relaxation. Radiation damage, image repeatability, and image quality assessments show little to no effects on the results. In conclusion, this approach is highly promising for future studies of human knee tissues to understand their microstructure, mechanical response, and progression in degenerative diseases.
Collapse
Affiliation(s)
- Hector Dejea
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00, Sweden
- MAX IV Laboratory, Lund University, Lund, 224 84, Sweden
| | - Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00, Sweden
| | - Gustavo A Orozco
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00, Sweden
| | | | - Stefan J Gstöhl
- Swiss Light Source, Paul Scherrer Institute, Villigen PSI, 5232, Switzerland
| | | | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00, Sweden
| |
Collapse
|
4
|
Silva Barreto I, Pierantoni M, Nielsen LC, Hammerman M, Diaz A, Novak V, Eliasson P, Liebi M, Isaksson H. Micro- and nanostructure specific X-ray tomography reveals less matrix formation and altered collagen organization following reduced loading during Achilles tendon healing. Acta Biomater 2024; 174:245-257. [PMID: 38096959 DOI: 10.1016/j.actbio.2023.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 12/06/2023] [Accepted: 12/07/2023] [Indexed: 12/25/2023]
Abstract
Recovery of the collagen structure following Achilles tendon rupture is poor, resulting in a high risk for re-ruptures. The loading environment during healing affects the mechanical properties of the tendon, but the relation between loading regime and healing outcome remains unclear. This is partially due to our limited understanding regarding the effects of loading on the micro- and nanostructure of the healing tissue. We addressed this through a combination of synchrotron phase-contrast X-ray microtomography and small-angle X-ray scattering tensor tomography (SASTT) to visualize the 3D organization of microscale fibers and nanoscale fibrils, respectively. The effect of in vivo loading on these structures was characterized in early healing of rat Achilles tendons by comparing full activity with immobilization. Unloading resulted in structural changes that can explain the reported impaired mechanical performance. In particular, unloading led to slower tissue regeneration and maturation, with less and more disorganized collagen, as well as an increased presence of adipose tissue. This study provides the first application of SASTT on soft musculoskeletal tissues and clearly demonstrates its potential to investigate a variety of other collagenous tissues. STATEMENT OF SIGNIFICANCE: Currently our understanding of the mechanobiological effects on the recovery of the structural hierarchical organization of injured Achilles tendons is limited. We provide insight into how loading affects the healing process by using a cutting-edge approach to for the first time characterize the 3D micro- and nanostructure of the regenerating collagen. We uncovered that, during early healing, unloading results in a delayed and more disorganized regeneration of both fibers (microscale) and fibrils (nanoscale), as well as increased presence of adipose tissue. The results set the ground for the development of further specialized protocols for tendon recovery.
Collapse
Affiliation(s)
| | - Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Leonard C Nielsen
- Department of Physics, Chalmers University of Technology, Gothenburg, Sweden
| | - Malin Hammerman
- Department of Biomedical Engineering, Lund University, Lund, Sweden; Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Ana Diaz
- Photon Science Division, Paul Scherrer Institute, Villigen PSI, Switzerland
| | - Vladimir Novak
- Photon Science Division, Paul Scherrer Institute, Villigen PSI, Switzerland
| | - Pernilla Eliasson
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden; Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Marianne Liebi
- Department of Physics, Chalmers University of Technology, Gothenburg, Sweden; Photon Science Division, Paul Scherrer Institute, Villigen PSI, Switzerland; Institute of materials, Ecole Polytechnique fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| |
Collapse
|
5
|
Furlani M, Riberti N, Gatto ML, Giuliani A. High-Resolution Phase-Contrast Tomography on Human Collagenous Tissues: A Comprehensive Review. Tomography 2023; 9:2116-2133. [PMID: 38133070 PMCID: PMC10748183 DOI: 10.3390/tomography9060166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/07/2023] [Accepted: 11/22/2023] [Indexed: 12/23/2023] Open
Abstract
Phase-contrast X-ray imaging is becoming increasingly considered since its first applications, which occurred almost 30 years ago. Particular emphasis was placed on studies that use this technique to investigate soft tissues, which cannot otherwise be investigated at a high resolution and in a three-dimensional manner, using conventional absorption-based settings. Indeed, its consistency and discrimination power in low absorbing samples, unified to being a not destructive analysis, are pushing interests on its utilization from researchers of different specializations, from botany, through zoology, to human physio-pathology research. In this regard, a challenging method for 3D imaging and quantitative analysis of collagenous tissues has spread in recent years: it is based on the unique characteristics of synchrotron radiation phase-contrast microTomography (PhC-microCT). In this review, the focus has been placed on the research based on the exploitation of synchrotron PhC-microCT for the investigation of collagenous tissue physio-pathologies from solely human samples. Collagen tissues' elasto-mechanic role bonds it to the morphology of the site it is extracted from, which could weaken the results coming from animal experimentations. Encouraging outcomes proved this technique to be suitable to access and quantify human collagenous tissues and persuaded different researchers to approach it. A brief mention was also dedicated to the results obtained on collagenous tissues using new and promising high-resolution phase-contrast tomographic laboratory-based setups, which will certainly represent the real step forward in the diffusion of this relatively young imaging technique.
Collapse
Affiliation(s)
- Michele Furlani
- Department DISCO, Università Politecnica delle Marche, Via Brecce Bianche 12, 60131 Ancona, Italy;
| | - Nicole Riberti
- Neuroscience Imaging and Clinical Sciences Department, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Maria Laura Gatto
- Department DIISM, Università Politecnica delle Marche, Via Brecce Bianche 12, 60131 Ancona, Italy;
| | - Alessandra Giuliani
- Department DISCO, Università Politecnica delle Marche, Via Brecce Bianche 12, 60131 Ancona, Italy;
| |
Collapse
|
6
|
Dizbay Sak S, Sevim S, Buyuksungur A, Kayı Cangır A, Orhan K. The Value of Micro-CT in the Diagnosis of Lung Carcinoma: A Radio-Histopathological Perspective. Diagnostics (Basel) 2023; 13:3262. [PMID: 37892083 PMCID: PMC10606474 DOI: 10.3390/diagnostics13203262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/12/2023] [Accepted: 10/17/2023] [Indexed: 10/29/2023] Open
Abstract
Micro-computed tomography (micro-CT) is a relatively new imaging modality and the three-dimensional (3D) images obtained via micro-CT allow researchers to collect both quantitative and qualitative information on various types of samples. Micro-CT could potentially be used to examine human diseases and several studies have been published on this topic in the last decade. In this study, the potential uses of micro-CT in understanding and evaluating lung carcinoma and the relevant studies conducted on lung and other tumors are summarized. Currently, the resolution of benchtop laboratory micro-CT units has not reached the levels that can be obtained with light microscopy, and it is not possible to detect the histopathological features (e.g., tumor type, adenocarcinoma pattern, spread through air spaces) required for lung cancer management. However, its ability to provide 3D images in any plane of section, without disturbing the integrity of the specimen, suggests that it can be used as an auxiliary technique, especially in surgical margin examination, the evaluation of tumor invasion in the entire specimen, and calculation of primary and metastatic tumor volume. Along with future developments in micro-CT technology, it can be expected that the image resolution will gradually improve, the examination time will decrease, and the relevant software will be more user friendly. As a result of these developments, micro-CT may enter pathology laboratories as an auxiliary method in the pathological evaluation of lung tumors. However, the safety, performance, and cost effectiveness of micro-CT in the areas of possible clinical application should be investigated. If micro-CT passes all these tests, it may lead to the convergence of radiology and pathology applications performed independently in separate units today, and the birth of a new type of diagnostician who has equal knowledge of the histological and radiological features of tumors.
Collapse
Affiliation(s)
- Serpil Dizbay Sak
- Department of Pathology, Faculty of Medicine, Ankara University, Ankara 06230, Turkey
| | - Selim Sevim
- Department of Pathology, Faculty of Medicine, Ankara University, Ankara 06230, Turkey
| | - Arda Buyuksungur
- Department of Basic Medical Sciences, Faculty of Dentistry, Ankara University, Ankara 06560, Turkey
| | - Ayten Kayı Cangır
- Department of Thoracic Surgery Ankara, Faculty of Medicine, Ankara University, Ankara 06230, Turkey
| | - Kaan Orhan
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06560, Turkey
| |
Collapse
|
7
|
Disney CM, Vo NT, Bodey AJ, Bay BK, Lee PD. Image quality and scan time optimisation for in situ phase contrast x-ray tomography of the intervertebral disc. J Mech Behav Biomed Mater 2023; 138:105579. [PMID: 36463809 DOI: 10.1016/j.jmbbm.2022.105579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 11/14/2022] [Accepted: 11/16/2022] [Indexed: 11/20/2022]
Abstract
In-line phase contrast synchrotron tomography combined with in situ mechanical loading enables the characterisation of soft tissue micromechanics via digital volume correlation (DVC) within whole organs. Optimising scan time is important for reducing radiation dose from multiple scans and to limit sample movement during acquisition. Also, although contrasted edges provided by in-line phase contrast tomography of soft tissues are useful for DVC, the effect of phase contrast imaging on its accuracy has yet to be investigated. Due to limited time at synchrotron facilities, scan parameters are often decided during imaging and their effect on DVC accuracy is not fully understood. Here, we used previously published data of intervertebral disc phase contrast tomography to evaluate the influence of i) fibrous image texture, ii) number of projections, iii) tomographic reconstruction method, and iv) phase contrast propagation distance on DVC results. A greater understanding of how image texture influences optimal DVC tracking was obtained by visualising objective function mapping, enabling tracking inaccuracies to be identified. When reducing the number of projections, DVC was minimally affected by image high frequency noise but with a compromise in accuracy. Iterative reconstruction methods improved image signal-to-noise and consequently significantly lowered DVC displacement uncertainty. Propagation distance was shown to affect DVC accuracy. Consistent DVC results were achieved within a propagation distance range which provided contrast to the smallest scale features, where; too short a distance provided insufficient features to track, whereas too long led to edge effect inconsistencies, particularly at greater deformations. Although limited to a single sample type and image setup, this study provides general guidelines for future investigations when optimising image quality and scan times for in situ phase contrast x-ray tomography of fibrous connective tissues.
Collapse
Affiliation(s)
- C M Disney
- Mechanical Engineering, University College London, UK; Diamond Light Source, UK.
| | - N T Vo
- Diamond Light Source, UK; National Synchrotron Light Source II, Brookhaven National Laboratory, USA
| | | | - B K Bay
- School of Mechanical, Industrial & Manufacturing Engineering, Oregon State University, USA
| | - P D Lee
- Mechanical Engineering, University College London, UK
| |
Collapse
|