1
|
Dejea H, Pierantoni M, Orozco GA, B Wrammerfors ET, Gstöhl SJ, Schlepütz CM, Isaksson H. In Situ Loading and Time-Resolved Synchrotron-Based Phase Contrast Tomography for the Mechanical Investigation of Connective Knee Tissues: A Proof-of-Concept Study. Adv Sci (Weinh) 2024:e2308811. [PMID: 38520713 DOI: 10.1002/advs.202308811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 02/26/2024] [Indexed: 03/25/2024]
Abstract
Articular cartilage and meniscus transfer and distribute mechanical loads in the knee joint. Degeneration of these connective tissues occurs during the progression of knee osteoarthritis, which affects their composition, microstructure, and mechanical properties. A deeper understanding of disease progression can be obtained by studying them simultaneously. Time-resolved synchrotron-based X-ray phase-contrast tomography (SR-PhC-µCT) allows to capture the tissue dynamics. This proof-of-concept study presents a rheometer setup for simultaneous in situ unconfined compression and SR-PhC-µCT of connective knee tissues. The microstructural response of bovine cartilage (n = 16) and meniscus (n = 4) samples under axial continuously increased strain, or two steps of 15% strain (stress-relaxation) is studied. The chondrocyte distribution in cartilage and the collagen fiber orientation in the meniscus are assessed. Variations in chondrocyte density reveal an increase in the top 40% of the sample during loading, compared to the lower half. Meniscus collagen fibers reorient perpendicular to the loading direction during compression and partially redisperse during relaxation. Radiation damage, image repeatability, and image quality assessments show little to no effects on the results. In conclusion, this approach is highly promising for future studies of human knee tissues to understand their microstructure, mechanical response, and progression in degenerative diseases.
Collapse
Affiliation(s)
- Hector Dejea
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00, Sweden
- MAX IV Laboratory, Lund University, Lund, 224 84, Sweden
| | - Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00, Sweden
| | - Gustavo A Orozco
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00, Sweden
| | | | - Stefan J Gstöhl
- Swiss Light Source, Paul Scherrer Institute, Villigen PSI, 5232, Switzerland
| | | | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00, Sweden
| |
Collapse
|
2
|
Markeviciute V, Puthia M, Arvidsson L, Liu Y, Törnquist E, Tengattini A, Huang J, Bai Y, Vater C, Petrolis R, Zwingenberger S, Krisciukaitis A, Smailys A, Lukosevicius S, Stravinskas M, Isaksson H, Tarasevicius S, Lidgren L, Tägil M, Raina DB. Systemically administered zoledronic acid activates locally implanted synthetic hydroxyapatite particles enhancing peri-implant bone formation: A regenerative medicine approach to improve fracture fixation. Acta Biomater 2024:S1742-7061(24)00124-7. [PMID: 38490481 DOI: 10.1016/j.actbio.2024.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 02/11/2024] [Accepted: 03/07/2024] [Indexed: 03/17/2024]
Abstract
Fracture fixation in an ageing population is challenging and fixation failure increases mortality and societal costs. We report a novel fracture fixation treatment by applying a hydroxyapatite (HA) based biomaterial at the bone-implant interface and biologically activating the biomaterial by systemic administration of a bisphosphonate (zoledronic acid, ZA). We first used an animal model of implant integration and applied a calcium sulphate (CaS)/HA biomaterial around a metallic screw in the tibia of osteoporotic rats. Using systemic ZA administration at 2-weeks post-surgery, we demonstrated that the implant surrounded by HA particles showed significantly higher peri‑implant bone formation compared to the unaugmented implants at 6-weeks. We then evaluated the optimal timing (day 1, 3, 7 and 14) of ZA administration to achieve a robust effect on peri‑implant bone formation. Using fluorescent ZA, we demonstrated that the uptake of ZA in the CaS/HA material was the highest at 3- and 7-days post-implantation and the uptake kinetics had a profound effect on the eventual peri‑implant bone formation. We furthered our concept in a feasibility study on trochanteric fracture patients randomized to either CaS/HA augmentation or no augmentation followed by systemic ZA treatment. Radiographically, the CaS/HA group showed signs of increased peri‑implant bone formation compared with the controls. Finally, apart from HA, we demonstrated that the concept of biologically activating a ceramic material by ZA could also be applied to β-tricalcium phosphate. This novel approach for fracture treatment that enhances immediate and long-term fracture fixation in osteoporotic bone could potentially reduce reoperations, morbidity and mortality. STATEMENT OF SIGNIFICANCE: • Fracture fixation in an ageing population is challenging. Biomaterial-based augmentation of fracture fixation devices has been attempted but lack of satisfactory biological response limits their widespread use. • We report the biological activation of locally implanted microparticulate hydroxyapatite (HA) particles placed around an implant by systemic administration of the bisphosphonate zoledronic acid (ZA). The biological activation of HA by ZA enhances peri‑implant bone formation. •Timing of ZA administration after HA implantation is critical for optimal ZA uptake and consequently determines the extent of peri‑implant bone formation. • We translate the developed concept from small animal models of implant integration to a proof-of-concept clinical study on osteoporotic trochanteric fracture patients. • ZA based biological activation can also be applied to other calcium phosphate biomaterials.
Collapse
Affiliation(s)
- Vetra Markeviciute
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania; The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden
| | - Manoj Puthia
- The Faculty of Medicine, Division of Dermatology and Venerology, Lund University, 221 84 Lund, Sweden
| | - Linnea Arvidsson
- The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden
| | - Yang Liu
- The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden; Department of Orthopedic Surgery, The Second Affiliated Hospital of Zhejiang University School of Medicine (SAHZU), Hangzhou, Zhejiang, China
| | - Elin Törnquist
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | | | - Jintian Huang
- The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden
| | - Yiguang Bai
- The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden; Cell, Tissue & Organ engineering laboratory, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, Lund, Sweden; Department of Orthopaedics, Nanchong Central Hospital, The Second Clinical Institute of North Sichuan Medical College Nanchong, Sichuan, China
| | - Corina Vater
- University Hospital Carl Gustav Carus at Technische Universität Dresden, University Center of Orthopedics, Trauma and Plastic Surgery, 01307 Dresden, Germany
| | - Robertas Petrolis
- Department of Physics, Mathematics and Biophysics, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Stefan Zwingenberger
- University Hospital Carl Gustav Carus at Technische Universität Dresden, University Center of Orthopedics, Trauma and Plastic Surgery, 01307 Dresden, Germany
| | - Algimantas Krisciukaitis
- Department of Physics, Mathematics and Biophysics, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Alfredas Smailys
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Saulius Lukosevicius
- Department of Radiology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Mindaugas Stravinskas
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Sarunas Tarasevicius
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Lars Lidgren
- The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden
| | - Magnus Tägil
- The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden
| | - Deepak Bushan Raina
- The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden.
| |
Collapse
|
3
|
B Wrammerfors ET, Törnquist E, Pierantoni M, Sjögren A, Tengattini A, Kaestner A, Zandt RI', Englund M, Isaksson H. Exploratory neutron tomography of articular cartilage. Osteoarthritis Cartilage 2024:S1063-4584(24)00934-8. [PMID: 38447631 DOI: 10.1016/j.joca.2024.02.889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 02/28/2024] [Accepted: 02/28/2024] [Indexed: 03/08/2024]
Abstract
OBJECTIVE To investigate the feasibility of using neutron tomography to gain new knowledge of human articular cartilage degeneration in osteoarthritis (OA). Different sample preparation techniques were evaluated to identify maximum intra-tissue contrast. DESIGN Human articular cartilage samples from 14 deceased donors (18-75 years, 9 males, 5 females) and 4 patients undergoing total knee replacement due to known OA (all female, 61-75 years) were prepared using different techniques: control in saline, treated with heavy water saline, fixed and treated in heavy water saline, and fixed and dehydrated with ethanol. Neutron tomographic imaging (isotropic voxel sizes from 7.5 to 13.5 µm) was performed at two large scale facilities. The 3D images were evaluated for gradients in hydrogen attenuation as well as compared to images from absorption X-ray tomography, magnetic resonance imaging, and histology. RESULTS Cartilage was distinguishable from background and other tissues in neutron tomographs. Intra-tissue contrast was highest in heavy water-treated samples, which showed a clear gradient from the cartilage surface to the bone interface. Increased neutron flux or exposure time improved image quality but did not affect the ability to detect gradients. Samples from older donors showed high variation in gradient profile, especially from donors with known OA. CONCLUSIONS Neutron tomography is a viable technique for specialized studies of cartilage, particularly for quantifying properties relating to the hydrogen density of the tissue matrix or water movement in the tissue.
Collapse
Affiliation(s)
| | - Elin Törnquist
- Department of Biomedical Engineering, Lund University (LU), Sweden
| | - Maria Pierantoni
- Department of Biomedical Engineering, Lund University (LU), Sweden
| | - Amanda Sjögren
- Clinical Epidemiology Unit, Orthopedics, Department of Clinical Sciences Lund, LU, Sweden
| | | | - Anders Kaestner
- Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut (PSI), Switzerland
| | | | - Martin Englund
- Clinical Epidemiology Unit, Orthopedics, Department of Clinical Sciences Lund, LU, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University (LU), Sweden
| |
Collapse
|
4
|
Axelsson I, Gustafsson A, Isaksson H, Nilsson J, Malm T. Impact of storage time prior to cryopreservation on mechanical properties of aortic homografts. Cell Tissue Bank 2024; 25:27-37. [PMID: 36843158 PMCID: PMC10902001 DOI: 10.1007/s10561-023-10079-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 02/04/2023] [Indexed: 02/28/2023]
Abstract
Optimal time spans in homograft procurement are still debatable among tissue banks and needs to be further investigated. Cell viability decreases at longer preparation intervals, but the effect on collagen and elastic fibers has not been investigated to the same extent. These fibers are of importance to the homograft elasticity and strength. The objective of this study was to analyze the mechanical properties of homograft tissue at different time spans in the procurement process. Ten aortic homografts were collected at the Tissue Bank in Lund. Twelve samples were obtained from each homograft, cryopreserved in groups of three after 2-4 days, 7-9 days, 28-30 days, and 60-62 days in antibiotic decontamination. Mechanical testing was performed with uniaxial tensile tests, calculating elastic modulus, yield stress and energy at yield stress. Two randomly selected samples were assessed with light microscopy. Procurement generated a total of 120 samples, with 30 samples in each time group. Elastic modulus and yield stress was significantly higher in samples cryopreserved after 2-4 days (2.7 MPa (2.5-5.0) and 0.78 MPa (0.68-1.0)) compared to 7-9 days (2.2 MPa (2.0-2.6) and 0.53 MPa (0.46-0.69)), p = 0.008 and 0.011 respectively. Light microscopy did not show any difference in collagen and elastin at different time spans. There was a significant decrease in elastic modulus and yield stress after 7 days of decontamination at 4 °C compared to 2-4 days. This could indicate some deterioration of elastin and collagen at longer decontamination intervals. Clinical significance of these findings remains to be clarified.
Collapse
Affiliation(s)
- Ida Axelsson
- Tissue Bank Lund, Baravägen 37, 22242, Lund, Sweden.
- Department of Cardiothoracic Surgery, Skane University Hospital, Lund, Sweden.
- Department of Clinical Science, Cardiothoracic Surgery, Lund University, Lund, Sweden.
| | - Anna Gustafsson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Johan Nilsson
- Department of Cardiothoracic Surgery, Skane University Hospital, Lund, Sweden
- Department of Clinical Science, Cardiothoracic Surgery, Lund University, Lund, Sweden
- Department of Translational Medicine, Artificial Intelligence and Bioinformatics in Cardiothoracic Sciences, Lund University, Lund, Sweden
| | - Torsten Malm
- Tissue Bank Lund, Baravägen 37, 22242, Lund, Sweden
- Department of Clinical Science, Cardiothoracic Surgery, Lund University, Lund, Sweden
- Pediatric Cardiac Surgery Unit, Children's Hospital, Skane University Hospital, Lund, Sweden
| |
Collapse
|
5
|
Axelsson I, Gustafsson A, Isaksson H, Nilsson J, Malm T. Correction to: Impact of storage time prior to cryopreservation on mechanical properties of aortic homografts. Cell Tissue Bank 2024; 25:39-41. [PMID: 37067750 PMCID: PMC10901928 DOI: 10.1007/s10561-023-10085-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/18/2023]
Affiliation(s)
- Ida Axelsson
- Tissue Bank Lund, Baravägen 37, 22242, Lund, Sweden.
- Department of Cardiothoracic Surgery, Skane University Hospital, Lund, Sweden.
- Department of Clinical Science, Cardiothoracic Surgery, Lund University, Lund, Sweden.
| | - Anna Gustafsson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Johan Nilsson
- Department of Cardiothoracic Surgery, Skane University Hospital, Lund, Sweden
- Department of Clinical Science, Cardiothoracic Surgery, Lund University, Lund, Sweden
- Department of Translational Medicine, Artificial Intelligence and Bioinformatics in Cardiothoracic Sciences, Lund University, Lund, Sweden
| | - Torsten Malm
- Tissue Bank Lund, Baravägen 37, 22242, Lund, Sweden
- Department of Clinical Science, Cardiothoracic Surgery, Lund University, Lund, Sweden
- Pediatric Cardiac Surgery Unit, Children's Hospital, Skane University Hospital, Lund, Sweden
| |
Collapse
|
6
|
Christierson L, Frieberg P, Lala T, Töger J, Liuba P, Revstedt J, Isaksson H, Hakacova N. Validation of fluid-structure interaction simulations of the opening phase of phantom mitral heart valves under physiologically inspired conditions. Comput Biol Med 2024; 171:108033. [PMID: 38430739 DOI: 10.1016/j.compbiomed.2024.108033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 12/22/2023] [Accepted: 01/26/2024] [Indexed: 03/05/2024]
Abstract
BACKGROUND AND OBJECTIVE Atrioventricular valve disease is a common cause of heart failure, and successful surgical or interventional outcomes are crucial. Patient-specific fluid-structure interaction (FSI) modeling may provide valuable insights into valve dynamics and guidance of valve repair strategies. However, lack of validation has kept FSI modeling from clinical implementation. Therefore, this study aims to validate FSI simulations against in vitro benchmarking data, based on clinically relevant parameters for evaluating heart valve disease. METHODS An FSI model that mimics the left heart was developed. The domain included a deformable mitral valve of different stiffnesses run with different inlet velocities. Five different cases were simulated and compared to in vitro data based on the pressure difference across the valve, the valve opening, and the velocity in the flow domain. RESULTS The simulations underestimate the pressure difference across the valve by 6.8-14 % compared to catheter measurements. Evaluation of the valve opening showed an underprediction of 5.4-7.3 % when compared to cine MRI, 2D Echo, and 3D Echo data. Additionally, the simulated velocity through the valve showed a 7.9-8.4 % underprediction in relation to Doppler Echo measurements. Qualitative assessment of the velocity profile in the ventricle and the streamlines of the flow in the domain showed good agreement of the flow behavior. CONCLUSIONS Parameters relevant to the diagnosis of heart valve disease estimated by FSI simulations showed good agreement when compared to in vitro benchmarking data, with differences small enough not to affect the grading of heart valve disease. The FSI model is thus deemed good enough for further development toward patient-specific cases.
Collapse
Affiliation(s)
- Lea Christierson
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden. Address: Barnhjärtcentrum mottagning, Skånes universitetssjukhus, Lasarettsgatan 48, 221 85, Lund, Sweden; Department of Biomedical Engineering, Lund University, Lund, Sweden. Address: Box 118, 221 00, Lund, Sweden.
| | - Petter Frieberg
- Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden. Address: Box 177, 221 00, Lund, Sweden
| | - Tania Lala
- Department of Biomedical Engineering, Lund University, Lund, Sweden. Address: Box 118, 221 00, Lund, Sweden; Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden. Address: Box 177, 221 00, Lund, Sweden
| | - Johannes Töger
- Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden. Address: Box 177, 221 00, Lund, Sweden
| | - Petru Liuba
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden. Address: Barnhjärtcentrum mottagning, Skånes universitetssjukhus, Lasarettsgatan 48, 221 85, Lund, Sweden
| | - Johan Revstedt
- Department of Energy Science, Lund University, Lund, Sweden. Address: Box 118, 221 00, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden. Address: Box 118, 221 00, Lund, Sweden
| | - Nina Hakacova
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden. Address: Barnhjärtcentrum mottagning, Skånes universitetssjukhus, Lasarettsgatan 48, 221 85, Lund, Sweden
| |
Collapse
|
7
|
Silva Barreto I, Pierantoni M, Nielsen LC, Hammerman M, Diaz A, Novak V, Eliasson P, Liebi M, Isaksson H. Micro- and nanostructure specific X-ray tomography reveals less matrix formation and altered collagen organization following reduced loading during Achilles tendon healing. Acta Biomater 2024; 174:245-257. [PMID: 38096959 DOI: 10.1016/j.actbio.2023.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 12/06/2023] [Accepted: 12/07/2023] [Indexed: 12/25/2023]
Abstract
Recovery of the collagen structure following Achilles tendon rupture is poor, resulting in a high risk for re-ruptures. The loading environment during healing affects the mechanical properties of the tendon, but the relation between loading regime and healing outcome remains unclear. This is partially due to our limited understanding regarding the effects of loading on the micro- and nanostructure of the healing tissue. We addressed this through a combination of synchrotron phase-contrast X-ray microtomography and small-angle X-ray scattering tensor tomography (SASTT) to visualize the 3D organization of microscale fibers and nanoscale fibrils, respectively. The effect of in vivo loading on these structures was characterized in early healing of rat Achilles tendons by comparing full activity with immobilization. Unloading resulted in structural changes that can explain the reported impaired mechanical performance. In particular, unloading led to slower tissue regeneration and maturation, with less and more disorganized collagen, as well as an increased presence of adipose tissue. This study provides the first application of SASTT on soft musculoskeletal tissues and clearly demonstrates its potential to investigate a variety of other collagenous tissues. STATEMENT OF SIGNIFICANCE: Currently our understanding of the mechanobiological effects on the recovery of the structural hierarchical organization of injured Achilles tendons is limited. We provide insight into how loading affects the healing process by using a cutting-edge approach to for the first time characterize the 3D micro- and nanostructure of the regenerating collagen. We uncovered that, during early healing, unloading results in a delayed and more disorganized regeneration of both fibers (microscale) and fibrils (nanoscale), as well as increased presence of adipose tissue. The results set the ground for the development of further specialized protocols for tendon recovery.
Collapse
Affiliation(s)
| | - Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Leonard C Nielsen
- Department of Physics, Chalmers University of Technology, Gothenburg, Sweden
| | - Malin Hammerman
- Department of Biomedical Engineering, Lund University, Lund, Sweden; Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Ana Diaz
- Photon Science Division, Paul Scherrer Institute, Villigen PSI, Switzerland
| | - Vladimir Novak
- Photon Science Division, Paul Scherrer Institute, Villigen PSI, Switzerland
| | - Pernilla Eliasson
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden; Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Marianne Liebi
- Department of Physics, Chalmers University of Technology, Gothenburg, Sweden; Photon Science Division, Paul Scherrer Institute, Villigen PSI, Switzerland; Institute of materials, Ecole Polytechnique fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| |
Collapse
|
8
|
Pierantoni M, Silva Barreto I, Hammerman M, Novak V, Diaz A, Engqvist J, Eliasson P, Isaksson H. Multimodal and multiscale characterization reveals how tendon structure and mechanical response are altered by reduced loading. Acta Biomater 2023; 168:264-276. [PMID: 37479155 DOI: 10.1016/j.actbio.2023.07.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 06/30/2023] [Accepted: 07/14/2023] [Indexed: 07/23/2023]
Abstract
Tendons are collagen-based connective tissues where the composition, structure and mechanics respond and adapt to the local mechanical environment. Adaptation to prolonged inactivity can result in stiffer tendons that are more prone to injury. However, the complex relation between reduced loading, structure, and mechanical performance is still not fully understood. This study combines mechanical testing with high-resolution synchrotron X-ray imaging, scattering techniques and histology to elucidate how reduced loading affects the structural properties and mechanical response of rat Achilles tendons on multiple length scales. The results show that reduced in vivo loading leads to more crimped and less organized fibers and this structural inhomogeneity could be the reason for the altered mechanical response. Unloading also seems to change the fibril response, possibly by altering the strain partitioning between hierarchical levels, and to reduce cell density. This study elucidates the relation between in vivo loading, the Achilles tendon nano-, meso‑structure and mechanical response. The results provide fundamental insights into the mechanoregulatory mechanisms guiding the intricate biomechanics, tissue structural organization, and performance of complex collagen-based tissues. STATEMENT OF SIGNIFICANCE: Achilles tendon properties allow a dynamic interaction between muscles and tendon and influence force transmission during locomotion. Lack of physiological loading can have dramatic effects on tendon structure and mechanical properties. We have combined the use of cutting-edge high-resolution synchrotron techniques with mechanical testing to show how reduced loading affects the tendon on multiple hierarchical levels (from nanoscale up to whole organ) clarifying the relation between structural changes and mechanical performance. Our findings set the first step to address a significant healthcare challenge, such as the design of tailored rehabilitations that take into consideration structural changes after tendon immobilization.
Collapse
Affiliation(s)
- Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden.
| | | | - Malin Hammerman
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden; Department of Biomedical and Clinical Sciences, Linköping University, 581 83 Linköping, Sweden
| | | | - Ana Diaz
- Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Jonas Engqvist
- Department of Solid Mechanics, Lund University, Box 118, 221 00 Lund, Sweden
| | - Pernilla Eliasson
- Department of Biomedical and Clinical Sciences, Linköping University, 581 83 Linköping, Sweden; Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden
| |
Collapse
|
9
|
Grassi L, Väänänen SP, Jehpsson L, Ljunggren Ö, Rosengren BE, Karlsson MK, Isaksson H. 3D Finite Element Models Reconstructed From 2D Dual-Energy X-Ray Absorptiometry (DXA) Images Improve Hip Fracture Prediction Compared to Areal BMD in Osteoporotic Fractures in Men (MrOS) Sweden Cohort. J Bone Miner Res 2023; 38:1258-1267. [PMID: 37417707 DOI: 10.1002/jbmr.4878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 06/15/2023] [Accepted: 07/04/2023] [Indexed: 07/08/2023]
Abstract
Bone strength is an important contributor to fracture risk. Areal bone mineral density (aBMD) derived from dual-energy X-ray absorptiometry (DXA) is used as a surrogate for bone strength in fracture risk prediction tools. 3D finite element (FE) models predict bone strength better than aBMD, but their clinical use is limited by the need for 3D computed tomography and lack of automation. We have earlier developed a method to reconstruct the 3D hip anatomy from a 2D DXA image, followed by subject-specific FE-based prediction of proximal femoral strength. In the current study, we aim to evaluate the method's ability to predict incident hip fractures in a population-based cohort (Osteoporotic Fractures in Men [MrOS] Sweden). We defined two subcohorts: (i) hip fracture cases and controls cohort: 120 men with a hip fracture (<10 years from baseline) and two controls to each hip fracture case, matched by age, height, and body mass index; and (ii) fallers cohort: 86 men who had fallen the year before their hip DXA scan was acquired, 15 of which sustained a hip fracture during the following 10 years. For each participant, we reconstructed the 3D hip anatomy and predicted proximal femoral strength in 10 sideways fall configurations using FE analysis. The FE-predicted proximal femoral strength was a better predictor of incident hip fractures than aBMD for both hip fracture cases and controls (difference in area under the receiver operating characteristics curve, ΔAUROC = 0.06) and fallers (ΔAUROC = 0.22) cohorts. This is the first time that FE models outperformed aBMD in predicting incident hip fractures in a population-based prospectively followed cohort based on 3D FE models obtained from a 2D DXA scan. Our approach has potential to notably improve the accuracy of fracture risk predictions in a clinically feasible manner (only one single DXA image is needed) and without additional costs compared to the current clinical approach. © 2023 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).
Collapse
Affiliation(s)
- Lorenzo Grassi
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Sami P Väänänen
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
- Department of Applied Physics, University of Eastern Finland, Eastern Finland, Finland
| | - Lars Jehpsson
- Department of Clinical Sciences Malmö, Lund University, Lund, Sweden
| | - Östen Ljunggren
- Department of Medical Sciences, Uppsala University, Uppsala, Sweden
| | - Björn E Rosengren
- Department of Clinical Sciences Malmö, Lund University, Lund, Sweden
| | - Magnus K Karlsson
- Department of Clinical Sciences Malmö, Lund University, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| |
Collapse
|
10
|
Dejea H, Raina DB, Silva Barreto I, Sharma K, Liu Y, Ferreira Sanchez D, Johansson U, Isaksson H. Multi-scale characterization of the spatio-temporal interplay between elemental composition, mineral deposition and remodelling in bone fracture healing. Acta Biomater 2023:S1742-7061(23)00356-2. [PMID: 37369267 DOI: 10.1016/j.actbio.2023.06.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 06/16/2023] [Accepted: 06/22/2023] [Indexed: 06/29/2023]
Abstract
Bone mineralization involves a complex orchestration of physico-chemical responses from the organism. Despite extensive studies, the detailed mechanisms of mineralization remain to be elucidated. This study aims to characterize bone mineralization using an in-vivo long bone fracture healing model in the rat. The spatio-temporal distribution of relevant elements was correlated to the deposition and maturation of hydroxyapatite and the presence of matrix remodeling compounds (MMP-13). Multi-scale measurements indicated that (i) zinc is required for both the initial mineral deposition and resorption processes during mature mineral remodeling; (ii) Zinc and MMP-13 show similar spatio-temporal trends during early mineralization; (iii) Iron acts locally and in coordination with zinc during mineralization, thus indicating novel evidence of the time-events and inter-play between the elements. These findings improve the understanding of bone mineralization by explaining the link between the different constituents of this process throughout the healing time. STATEMENT OF SIGNIFICANCE: Bone mineralization involves a complex orchestration of physico-chemical responses from the organism, the detailed mechanisms of which remain to be elucidated. This study presents a highly novel multi-scale multi-modal investigation of bone mineralization using bone fracture healing as a model system. We present original characterization of tissue mineralization, where we relate the spatio-temporal distribution of important trace elements to a key matrix remodeling compound (MMP-13), the initial deposition and maturation of hydroxyapatite and further remodeling processes. This is the first time that mineralization has been probed down to the nanometric level, and where key mineralization components have been investigated to achieve a comprehensive and mechanistic understanding of the underlying mineralization processes during bone healing.
Collapse
Affiliation(s)
- Hector Dejea
- Department of Biomedical Engineering, Lund University, 223 62 Lund, Sweden, MAX IV Laboratory, Lund University, 224 84 Lund, Sweden.
| | - Deepak Bushan Raina
- Orthopedics, Department of Clinical Sciences, Lund University, 223 62 Lund, Sweden.
| | | | - Kunal Sharma
- Department of Biomedical Engineering, Lund University, 223 62 Lund, Sweden.
| | - Yang Liu
- Orthopedics, Department of Clinical Sciences, Lund University, 223 62 Lund, Sweden.
| | | | - Ulf Johansson
- MAX IV Laboratory, Lund University, 224 84 Lund, Sweden.
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, 223 62 Lund, Sweden.
| |
Collapse
|
11
|
Iwarsson S, Jönson H, Deierborg T, Ehinger JK, Hansson O, Isaksson H, Englund M. 'Proactive aging' is a new research approach for a new era. Nat Aging 2023:10.1038/s43587-023-00438-6. [PMID: 37291219 DOI: 10.1038/s43587-023-00438-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Affiliation(s)
| | - Håkan Jönson
- School of Social Work, Lund University, Lund, Sweden
| | - Tomas Deierborg
- Experimental Neuroinflammation Laboratory, Department of Experimental Medical Science, Lund University, Lund, Sweden
| | - Johannes K Ehinger
- Otorhinolaryngology, Head and Neck Surgery, Department of Clinical Sciences Lund, Lund University, Lund, Sweden
- Mitochondrial Medicine, Department of Clinical Sciences Lund, Lund University, Lund, Sweden
- Otorhinolaryngology, Head and Neck Surgery, Skåne University Hospital, Lund, Sweden
| | - Oskar Hansson
- Clinical Memory Research Unit, Department of Clinical Sciences Malmö, Lund University, Malmö, Sweden
- Memory Clinic, Skåne University Hospital, Malmö, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Martin Englund
- Clinical Epidemiology Unit, Orthopedics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden
- Orthopedics, Skåne University Hospital, Lund, Sweden
| |
Collapse
|
12
|
Pierantoni M, Hammerman M, Silva Barreto I, Larsson D, Notermans T, Bodey AJ, Eliasson P, Isaksson H. Spatiotemporal and microstructural characterization of heterotopic ossification in healing rat Achilles tendons. FASEB J 2023; 37. [PMID: 37219456 DOI: 10.1096/fj.202201018rrr] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 04/18/2023] [Accepted: 05/05/2023] [Indexed: 05/24/2023]
Abstract
Achilles tendon rupture is a common debilitating medical condition. The healing process is slow and can be affected by heterotopic ossification (HO), which occurs when pathologic bone-like tissue is deposited instead of the soft collagenous tendon tissue. Little is known about the temporal and spatial progression of HO during Achilles tendon healing. In this study we characterize HO deposition, microstructure, and location at different stages of healing in a rat model. We use phase contrast-enhanced synchrotron microtomography, a state-of-the-art technique that allows 3D imaging at high-resolution of soft biological tissues without invasive or time-consuming sample preparation. The results increase our understanding of HO deposition, from the early inflammatory phase of tendon healing, by showing that the deposition is initiated as early as one week after injury in the distal stump and mostly growing on preinjury HO deposits. Later, more deposits form first in the stumps and then all over the tendon callus, merging into large, calcified structures, which occupy up to 10% of the tendon volume. The HOs were characterized by a looser connective trabecular-like structure and a proteoglycan-rich matrix containing chondrocyte-like cells with lacunae. The study shows the potential of 3D imaging at high-resolution by phase-contrast tomography to better understand ossification in healing tendons.
Collapse
Affiliation(s)
- Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Malin Hammerman
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | | | - Daniel Larsson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Thomas Notermans
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | | | - Pernilla Eliasson
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| |
Collapse
|
13
|
Isaksson H, Brännström Å, Libby E. Minor variations in multicellular life cycles have major effects on adaptation. PLoS Comput Biol 2023; 19:e1010698. [PMID: 37083675 PMCID: PMC10156057 DOI: 10.1371/journal.pcbi.1010698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 05/03/2023] [Accepted: 03/29/2023] [Indexed: 04/22/2023] Open
Abstract
Multicellularity has evolved several independent times over the past hundreds of millions of years and given rise to a wide diversity of complex life. Recent studies have found that large differences in the fundamental structure of early multicellular life cycles can affect fitness and influence multicellular adaptation. Yet, there is an underlying assumption that at some scale or categorization multicellular life cycles are similar in terms of their adaptive potential. Here, we consider this possibility by exploring adaptation in a class of simple multicellular life cycles of filamentous organisms that only differ in one respect, how many daughter filaments are produced. We use mathematical models and evolutionary simulations to show that despite the similarities, qualitatively different mutations fix. In particular, we find that mutations with a tradeoff between cell growth and group survival, i.e. "selfish" or "altruistic" traits, spread differently. Specifically, altruistic mutations more readily spread in life cycles that produce few daughters while in life cycles producing many daughters either type of mutation can spread depending on the environment. Our results show that subtle changes in multicellular life cycles can fundamentally alter adaptation.
Collapse
Affiliation(s)
- Hanna Isaksson
- Department of Mathematics and Mathematical Statistics, Umeå University, Umeå, Sweden
- IceLab, Umeå University, Umeå, Sweden
| | - Åke Brännström
- Department of Mathematics and Mathematical Statistics, Umeå University, Umeå, Sweden
- IceLab, Umeå University, Umeå, Sweden
- Advancing Systems Analysis Program, International Institute for Applied Systems Analysis (IIASA), Laxenburg, Austria
- Complexity Science and Evolution Unit, Okinawa Institute of Science and Technology Graduate University, Kunigami, Japan
| | - Eric Libby
- Department of Mathematics and Mathematical Statistics, Umeå University, Umeå, Sweden
- IceLab, Umeå University, Umeå, Sweden
| |
Collapse
|
14
|
Orozco GA, Ristaniemi A, Haghighatnejad M, Mohammadi A, Finnilä MAJ, Saarakkala S, Herzog W, Isaksson H, Korhonen RK. Adaptation of Fibril-Reinforced Poroviscoelastic Properties in Rabbit Collateral Ligaments 8 Weeks After Anterior Cruciate Ligament Transection. Ann Biomed Eng 2023; 51:726-740. [PMID: 36129552 PMCID: PMC10023629 DOI: 10.1007/s10439-022-03081-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 09/07/2022] [Indexed: 11/30/2022]
Abstract
Ligaments of the knee provide stability and prevent excessive motions of the joint. Rupture of the anterior cruciate ligament (ACL), a common sports injury, results in an altered loading environment for other tissues in the joint, likely leading to their mechanical adaptation. In the collateral ligaments, the patterns and mechanisms of biomechanical adaptation following ACL transection (ACLT) remain unknown. We aimed to characterize the adaptation of elastic and viscoelastic properties of the lateral and medial collateral ligaments eight weeks after ACLT. Unilateral ACLT was performed in six rabbits, and collateral ligaments were harvested from transected and contralateral knee joints after eight weeks, and from an intact control group (eight knees from four animals). The cross-sectional areas were measured with micro-computed tomography. Stepwise tensile stress-relaxation testing was conducted up to 6% final strain, and the elastic and viscoelastic properties were characterized with a fibril-reinforced poroviscoelastic material model. We found that the cross-sectional area of the collateral ligaments in the ACL transected knees increased, the nonlinear elastic collagen network modulus of the LCL decreased, and the amount of fast relaxation in the MCL decreased. Our results indicate that rupture of the ACL leads to an early adaptation of the elastic and viscoelastic properties of the collagen fibrillar network in the collateral ligaments. These adaptations may be important to consider when evaluating whole knee joint mechanics after ACL rupture, and the results aid in understanding the consequences of ACL rupture on other tissues.
Collapse
Affiliation(s)
- Gustavo A Orozco
- Department of Applied Physics, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland.
- Department of Biomedical Engineering, Lund University, Box 188, 221 00, Lund, Sweden.
| | - Aapo Ristaniemi
- Department of Applied Physics, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland
- AO Research Institute Davos, Davos, Switzerland
| | - Mehrnoush Haghighatnejad
- Department of Applied Physics, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland
| | - Ali Mohammadi
- Department of Applied Physics, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland
| | - Mikko A J Finnilä
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
| | - Simo Saarakkala
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
- Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland
| | - Walter Herzog
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Canada
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 188, 221 00, Lund, Sweden
| | - Rami K Korhonen
- Department of Applied Physics, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland
| |
Collapse
|
15
|
Orozco GA, Karjalainen K, Moo EK, Stenroth L, Tanska P, Rios JL, Tuomainen TV, Nissi MJ, Isaksson H, Herzog W, Korhonen RK. Correction: A musculoskeletal finite element model of rat knee joint for evaluating cartilage biomechanics during gait. PLoS Comput Biol 2023; 19:e1011025. [PMID: 36989216 DOI: 10.1371/journal.pcbi.1011025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023] Open
Abstract
[This corrects the article DOI: 10.1371/journal.pcbi.1009398.].
Collapse
|
16
|
Pierantoni M, Hammerman M, Silva Barreto I, Andersson L, Novak V, Isaksson H, Eliasson P. Heterotopic mineral deposits in intact rat Achilles tendons are characterized by a unique fiber-like structure. J Struct Biol X 2023; 7:100087. [PMID: 36938139 PMCID: PMC10018562 DOI: 10.1016/j.yjsbx.2023.100087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 02/16/2023] [Accepted: 02/19/2023] [Indexed: 02/26/2023] Open
Abstract
Heterotopic mineralization entails pathological mineral formation inside soft tissues. In human tendons mineralization is often associated with tendinopathies, tendon weakness and pain. In Achilles tendons, mineralization is considered to occur through heterotopic ossification (HO) primarily in response to tendon pathologies. However, refined details regarding HO deposition and microstructure are unknown. In this study, we characterize HO in intact rat Achilles tendons through high-resolution phase contrast enhanced synchrotron X-ray tomography. Furthermore, we test the potential of studying local tissue injury by needling intact Achilles tendons and the relation between tissue microdamage and HO. The results show that HO occurs in all intact Achilles tendons at 16 weeks of age. HO deposits are characterized by an elongated ellipsoidal shape and by a fiber-like internal structure which suggests that some collagen fibers have mineralized. The data indicates that deposition along fibers initiates in the pericellular area, and propagates into the intercellular area. Within HO deposits cells are larger and more rounded compared to tenocytes between unmineralized fibers, which are fewer and elongated. The results also indicate that multiple HO deposits may merge into bigger structures with time by accession along unmineralized fibers. Furthermore, the presence of unmineralized regions within the deposits may indicate that HOs are not only growing, but mineral resorption may also occur. Additionally, phase contrast synchrotron X-ray tomography allowed to distinguish microdamage at the fiber level in response to needling. The needle injury protocol could in the future enable to elucidate the relation between local inflammation, microdamage, and HO deposition.
Collapse
Affiliation(s)
- Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden
- Corresponding author.
| | - Malin Hammerman
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden
- Department of Biomedical and Clinical Sciences, Linköping University, 581 83 Linköping, Sweden
| | | | - Linnea Andersson
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden
| | - Vladimir Novak
- Swiss Light Source, Paul Scherrer Institute, CH-5232 Villigen, Switzerland
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden
| | - Pernilla Eliasson
- Department of Biomedical and Clinical Sciences, Linköping University, 581 83 Linköping, Sweden
- Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
17
|
Silva Barreto I, Pierantoni M, Hammerman M, Törnquist E, Le Cann S, Diaz A, Engqvist J, Liebi M, Eliasson P, Isaksson H. Nanoscale characterization of collagen structural responses to in situ loading in rat Achilles tendons. Matrix Biol 2023; 115:32-47. [PMID: 36435426 DOI: 10.1016/j.matbio.2022.11.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 09/29/2022] [Accepted: 11/21/2022] [Indexed: 11/24/2022]
Abstract
The specific viscoelastic mechanical properties of Achilles tendons are highly dependent on the structural characteristics of collagen at and between all hierarchical levels. Research has been conducted on the deformation mechanisms of positional tendons and single fibrils, but knowledge about the coupling between the whole tendon and nanoscale deformation mechanisms of more commonly injured energy-storing tendons, such as Achilles tendons, remains sparse. By exploiting the highly periodic arrangement of tendons at the nanoscale, in situ loading of rat Achilles tendons during small-angle X-ray scattering acquisition was used to investigate the collagen structural response during load to rupture, cyclic loading and stress relaxation. The fibril strain was substantially lower than the applied tissue strain. The fibrils strained linearly in the elastic region of the tissue, but also exhibited viscoelastic properties, such as an increased stretchability and recovery during cyclic loading and fibril strain relaxation during tissue stress relaxation. We demonstrate that the changes in the width of the collagen reflections could be attributed to strain heterogeneity and not changes in size of the coherently diffracting domains. Fibril strain heterogeneity increased with applied loads and after the toe region, fibrils also became increasingly disordered. Additionally, a thorough evaluation of radiation damage was performed. In conclusion, this study clearly displays the simultaneous structural response and adaption of the collagen fibrils to the applied tissue loads and provide novel information about the transition of loads between length scales in the Achilles tendon.
Collapse
Affiliation(s)
| | - Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Malin Hammerman
- Department of Biomedical Engineering, Lund University, Lund, Sweden; Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Elin Törnquist
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Sophie Le Cann
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, Créteil F-94010, France
| | - Ana Diaz
- Paul Scherrer Institut, Villigen PSI, Switzerland
| | - Jonas Engqvist
- Division of Solid Mechanics, Lund University, Lund, Sweden
| | - Marianne Liebi
- Paul Scherrer Institut, Villigen PSI, Switzerland; Department of Physics, Chalmers University, Gothenburg, Sweden; Center of X-ray Analytics, Empa, Swiss Federal Laboratories for Materials Science and Technology, St.Gallen, Switzerland
| | - Pernilla Eliasson
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden; Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden.
| |
Collapse
|
18
|
Notermans T, Isaksson H. Predicting the formation of different tissue types during Achilles tendon healing using mechanoregulated and oxygen-regulated frameworks. Biomech Model Mechanobiol 2022; 22:655-667. [PMID: 36542228 PMCID: PMC10097799 DOI: 10.1007/s10237-022-01672-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 12/08/2022] [Indexed: 12/24/2022]
Abstract
AbstractDuring Achilles tendon healing in rodents, besides the expected tendon tissue, also cartilage-, bone- and fat-like tissue features have been observed during the first twenty weeks of healing. Several studies have hypothesized that mechanical loading may play a key role in the formation of different tissue types during healing. We recently developed a computational mechanobiological framework to predict tendon tissue production, organization and mechanical properties during tendon healing. In the current study, we aimed to explore possible mechanobiological related mechanisms underlying formation of other tissue types than tendon tissue during tendon healing. To achieve this, we further developed our recent framework to predict formation of different tissue types, based on mechanobiological models established in other fields, which have earlier not been applied to study tendon healing. We explored a wide range of biophysical stimuli, i.e., principal strain, hydrostatic stress, pore pressure, octahedral shear strain, fluid flow, angiogenesis and oxygen concentration, that may promote the formation of different tissue types. The numerical framework predicted spatiotemporal formation of tendon-, cartilage-, bone- and to a lesser degree fat-like tissue throughout the first twenty weeks of healing, similar to recent experimental reports. Specific features of experimental data were captured by different biophysical stimuli. Our modeling approach showed that mechanobiology may play a role in governing the formation of different tissue types that have been experimentally observed during tendon healing. This study provides a numerical tool that can contribute to a better understanding of tendon mechanobiology during healing. Developing these tools can ultimately lead to development of better rehabilitation regimens that stimulate tendon healing and prevent unwanted formation of cartilage-, fat- and bone-like tissues.
Collapse
Affiliation(s)
- Thomas Notermans
- Department of Biomedical Engineering, Lund University, Lund, Sweden.
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| |
Collapse
|
19
|
Sotiriou V, Huang Y, Ahmed S, Isaksson H, Nowlan NC, Nowlan NC. Prenatal murine skeletogenesis partially recovers from absent skeletal muscle as development progresses. Eur Cell Mater 2022; 44:115-132. [PMID: 36345651 DOI: 10.22203/ecm.v044a08] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Skeletal muscle contractions are critical for normal skeletal growth and morphogenesis but it is unclear how the detrimental effects of absent muscle on the bones and joints change over time. Joint shape and cavitation as well as rudiment length and mineralisation were assessed in multiple rudiments at two developmental stages [Theiler stage (TS)24 and TS27] in the splotch-delayed "muscle-less limb" mouse model and littermate controls. Chondrocyte morphology was quantified in 3D in the distal humerus at the same stages. As development progressed, the effects of absent muscle on all parameters except for cavitation become less severe. All major joints in muscle-less limbs were abnormally shaped at TS24, while, by TS27, most muscle-less limb joint shapes were normal or nearly normal. In contrast, any joints that were fused at TS24 did not cavitate by TS27. At TS24, chondrocytes in the distal humerus were significantly smaller in the muscle-less limbs than in controls, while by TS27, chondrocyte volume was similar between the two groups, offering a cell-level mechanism for the partial recovery in shape of muscle-less limbs. Mineralisation showed the most pronounced changes over gestation. At TS24, all muscle-less rudiments studied had less mineralisation than the controls, while at TS27, muscle-less limb rudiments had mineralisation extents equivalent to controls. In conclusion, the effects of muscle absence on prenatal murine skeletogenesis reduced in severity over gestation. Understanding how mammalian bones and joints continue to develop in an environment with abnormal fetal movements provides insights into conditions including hip dysplasia and arthrogryposis.
Collapse
Affiliation(s)
| | | | | | | | - N C Nowlan
- School of Mechanical and Materials Engineering, University College Dublin (UCD), Dublin 4,
| | | |
Collapse
|
20
|
Grigoryan A, Zacharaki D, Balhuizen A, Côme CR, Garcia AG, Hidalgo Gil D, Frank AK, Aaltonen K, Mañas A, Esfandyari J, Kjellman P, Englund E, Rodriguez C, Sime W, Massoumi R, Kalantari N, Prithiviraj S, Li Y, Dupard SJ, Isaksson H, Madsen CD, Porse BT, Bexell D, Bourgine PE. Engineering human mini-bones for the standardized modeling of healthy hematopoiesis, leukemia, and solid tumor metastasis. Sci Transl Med 2022; 14:eabm6391. [PMID: 36223446 DOI: 10.1126/scitranslmed.abm6391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
The bone marrow microenvironment provides indispensable factors to sustain blood production throughout life. It is also a hotspot for the progression of hematologic disorders and the most frequent site of solid tumor metastasis. Preclinical research relies on xenograft mouse models, but these models preclude the human-specific functional interactions of stem cells with their bone marrow microenvironment. Instead, human mesenchymal cells can be exploited for the in vivo engineering of humanized niches, which confer robust engraftment of human healthy and malignant blood samples. However, mesenchymal cells are associated with major reproducibility issues in tissue formation. Here, we report the fast and standardized generation of human mini-bones by a custom-designed human mesenchymal cell line. These resulting humanized ossicles (hOss) consist of fully mature bone and bone marrow structures hosting a human mesenchymal niche with retained stem cell properties. As compared to mouse bones, we demonstrate superior engraftment of human cord blood hematopoietic cells and primary acute myeloid leukemia samples and also validate hOss as a metastatic site for breast cancer cells. We further report the engraftment of neuroblastoma patient-derived xenograft cells in a humanized model, recapitulating clinically described osteolytic lesions. Collectively, our human mini-bones constitute a powerful preclinical platform to model bone-developing tumors using patient-derived materials.
Collapse
Affiliation(s)
- Ani Grigoryan
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| | - Dimitra Zacharaki
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| | - Alexander Balhuizen
- The Finsen Laboratory, Rigshospitalet, Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark.,Biotech Research and Innovation Center (BRIC), University of Copenhagen, 2200 Copenhagen, Denmark.,Danish Stem Cell Center (DanStem), Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Christophe Rm Côme
- The Finsen Laboratory, Rigshospitalet, Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark.,Biotech Research and Innovation Center (BRIC), University of Copenhagen, 2200 Copenhagen, Denmark.,Danish Stem Cell Center (DanStem), Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Alejandro Garcia Garcia
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| | - David Hidalgo Gil
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| | - Anne-Katrine Frank
- The Finsen Laboratory, Rigshospitalet, Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark.,Biotech Research and Innovation Center (BRIC), University of Copenhagen, 2200 Copenhagen, Denmark.,Danish Stem Cell Center (DanStem), Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Kristina Aaltonen
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Adriana Mañas
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Javanshir Esfandyari
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Pontus Kjellman
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Emelie Englund
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Carmen Rodriguez
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Wondossen Sime
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Ramin Massoumi
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Nasim Kalantari
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| | - Sujeethkumar Prithiviraj
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| | - Yuan Li
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| | - Steven J Dupard
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, 221 85 Lund, Sweden
| | - Chris D Madsen
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Bo T Porse
- The Finsen Laboratory, Rigshospitalet, Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark.,Biotech Research and Innovation Center (BRIC), University of Copenhagen, 2200 Copenhagen, Denmark.,Danish Stem Cell Center (DanStem), Faculty of Health Sciences, University of Copenhagen, 2200 Copenhagen, Denmark
| | - Daniel Bexell
- Division of Translational Cancer Research, Department of Laboratory Medicine, Lund University, 223 81 Lund, Sweden
| | - Paul E Bourgine
- Cell, Tissue & Organ engineering laboratory, Biomedical Centre (BMC) B11, Department of Clinical Sciences Lund, Stem Cell Centre, Lund University, 221 84 Lund, Sweden.,Wallenberg Centre for Molecular Medicine, Lund University, 221 84 Lund, Sweden
| |
Collapse
|
21
|
Finnilä MAJ, Das Gupta S, Turunen MJ, Hellberg I, Turkiewicz A, Lutz-Bueno V, Jonsson E, Holler M, Ali N, Hughes V, Isaksson H, Tjörnstrand J, Önnerfjord P, Guizar-Sicairos M, Saarakkala S, Englund M. Mineral Crystal Thickness in Calcified Cartilage and Subchondral Bone in Healthy and Osteoarthritic Human Knees. J Bone Miner Res 2022; 37:1700-1710. [PMID: 35770824 PMCID: PMC9540032 DOI: 10.1002/jbmr.4642] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 05/17/2022] [Accepted: 06/26/2022] [Indexed: 11/08/2022]
Abstract
Osteoarthritis (OA) is the most common joint disease, where articular cartilage degradation is often accompanied with sclerosis of the subchondral bone. However, the association between OA and tissue mineralization at the nanostructural level is currently not understood. In particular, it is technically challenging to study calcified cartilage, where relevant but poorly understood pathological processes such as tidemark multiplication and advancement occur. Here, we used state-of-the-art microfocus small-angle X-ray scattering with a 5-μm spatial resolution to determine the size and organization of the mineral crystals at the nanostructural level in human subchondral bone and calcified cartilage. Specimens with a wide spectrum of OA severities were acquired from both medial and lateral compartments of medial compartment knee OA patients (n = 15) and cadaver knees (n = 10). Opposing the common notion, we found that calcified cartilage has thicker and more mutually aligned mineral crystals than adjoining bone. In addition, we, for the first time, identified a well-defined layer of calcified cartilage associated with pathological tidemark multiplication, containing 0.32 nm thicker crystals compared to the rest of calcified cartilage. Finally, we found 0.2 nm thicker mineral crystals in both tissues of the lateral compartment in OA compared with healthy knees, indicating a loading-related disease process because the lateral compartment is typically less loaded in medial compartment knee OA. In summary, we report novel changes in mineral crystal thickness during OA. Our data suggest that unloading in the knee might be involved with the growth of mineral crystals, which is especially evident in the calcified cartilage. © 2022 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).
Collapse
Affiliation(s)
- Mikko A J Finnilä
- Research Unit of Medical Imaging, Physics and Technology, Faculty of Medicine, University of Oulu, Oulu, Finland.,Medical Research Center, University of Oulu, Oulu, Finland
| | - Shuvashis Das Gupta
- Research Unit of Medical Imaging, Physics and Technology, Faculty of Medicine, University of Oulu, Oulu, Finland
| | - Mikael J Turunen
- Department of Applied Physics, Faculty of Science and Forestry, University of Eastern Finland, Kuopio, Finland
| | - Iida Hellberg
- Research Unit of Medical Imaging, Physics and Technology, Faculty of Medicine, University of Oulu, Oulu, Finland
| | - Aleksandra Turkiewicz
- Clinical Epidemiology Unit, Orthopaedics, Department of Clinical Sciences Lund, Faculty of Medicine, Lund University, Lund, Sweden
| | | | - Elin Jonsson
- Clinical Epidemiology Unit, Orthopaedics, Department of Clinical Sciences Lund, Faculty of Medicine, Lund University, Lund, Sweden
| | - Mirko Holler
- Paul Scherrer Institut, Villigen PSI, Switzerland
| | - Neserin Ali
- Clinical Epidemiology Unit, Orthopaedics, Department of Clinical Sciences Lund, Faculty of Medicine, Lund University, Lund, Sweden
| | - Velocity Hughes
- Clinical Epidemiology Unit, Orthopaedics, Department of Clinical Sciences Lund, Faculty of Medicine, Lund University, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Jon Tjörnstrand
- Department of Orthopaedics, Skåne University Hospital, Lund, Sweden
| | - Patrik Önnerfjord
- Rheumatology and Molecular Skeletal Biology, Department of Clinical Sciences Lund, Faculty of Medicine, Lund University, Lund, Sweden
| | | | - Simo Saarakkala
- Research Unit of Medical Imaging, Physics and Technology, Faculty of Medicine, University of Oulu, Oulu, Finland.,Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland
| | - Martin Englund
- Clinical Epidemiology Unit, Orthopaedics, Department of Clinical Sciences Lund, Faculty of Medicine, Lund University, Lund, Sweden
| |
Collapse
|
22
|
Einarsson E, Pierantoni M, Novak V, Svensson J, Isaksson H, Englund M. Phase-contrast enhanced synchrotron micro-tomography of human meniscus tissue. Osteoarthritis Cartilage 2022; 30:1222-1233. [PMID: 35750240 DOI: 10.1016/j.joca.2022.06.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 05/27/2022] [Accepted: 06/13/2022] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To investigate the feasibility of synchrotron radiation-based phase contrast enhanced micro-computed tomography (SR-PhC-μCT) for imaging of human meniscus. Quantitative parameters related to fiber orientation and crimping were evaluated as potential markers of tissue degeneration. DESIGN Human meniscus specimens from 10 deceased donors were prepared using different preparation schemes: fresh frozen and thawed before imaging or fixed and paraffin-embedded. The samples were imaged using SR-PhC-μCT with an isotropic voxel size of 1.625 μm. Image quality was evaluated by visual inspection and spatial resolution. Fiber voxels were defined using a grey level threshold and a structure tensor analysis was applied to estimate collagen fiber orientation. The area at half maximum (FAHM) was calculated from angle histograms to quantify orientation distribution. Crimping period was calculated from the power spectrum of image profiles of crimped fibers. Parameters were compared to degenerative stage as evaluated by Pauli histopathological scoring. RESULTS Image quality was similar between frozen and embedded samples and spatial resolutions ranged from 5.1 to 5.8 μm. Fiber structure, including crimping, was clearly visible in the images. Fibers appeared to be less organized closer to the tip of the meniscus. Fiber density might decrease slightly with degeneration. FAHM and crimping period did not show any clear association with histopathological scoring. CONCLUSION SR-PhC-μCT is a feasible technique for high-resolution 3D imaging of fresh frozen meniscus tissue. Further work is needed to establish quantitative parameters that relate to tissue degeneration, but this imaging technique is promising for future studies of meniscus structure and biomechanical response.
Collapse
Affiliation(s)
- E Einarsson
- Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden; Clinical Epidemiology Unit, Orthopedics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
| | - M Pierantoni
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - V Novak
- Swiss Light Source, Paul Scherrer Institute, Villigen, Switzerland
| | - J Svensson
- Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden; Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
| | - H Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - M Englund
- Clinical Epidemiology Unit, Orthopedics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden
| |
Collapse
|
23
|
Dall'Ara E, Bodey AJ, Isaksson H, Tozzi G. A practical guide for in situ mechanical testing of musculoskeletal tissues using synchrotron tomography. J Mech Behav Biomed Mater 2022; 133:105297. [PMID: 35691205 DOI: 10.1016/j.jmbbm.2022.105297] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 05/03/2022] [Accepted: 05/25/2022] [Indexed: 02/07/2023]
Abstract
Musculoskeletal tissues are complex hierarchical materials where mechanical response is linked to structural and material properties at different dimensional levels. Therefore, high-resolution three-dimensional tomography is very useful for assessing tissue properties at different scales. In particular, Synchrotron Radiation micro-Computed Tomography (SR-microCT) has been used in several applications to analyze the structure of bone and biomaterials. In the past decade the development of digital volume correlation (DVC) algorithms applied to SR-microCT images and its combination with in situ mechanical testing (four-dimensional imaging) have allowed researchers to visualise, for the first time, the deformation of musculoskeletal tissues and their interaction with biomaterials under different loading scenarios. However, there are several experimental challenges that make these measurements difficult and at high risk of failure. Challenges relate to sample preparation, imaging parameters, loading setup, accumulated tissue damage for multiple tomographic acquisitions, reconstruction methods and data processing. Considering that access to SR-microCT facilities is usually associated with bidding processes and long waiting times, the failure of these experiments could notably slow down the advancement of this research area and reduce its impact. Many of the experimental failures can be avoided with increased experience in performing the tests and better guidelines for preparation and execution of these complex experiments; publication of negative results could help interested researchers to avoid recurring mistakes. Therefore, the goal of this article is to highlight the potential and pitfalls in the design and execution of in situ SR-microCT experiments, involving multiple scans, of musculoskeletal tissues for the assessment of their structural and/or mechanical properties. The advice and guidelines that follow should improve the success rate of this type of experiment, allowing the community to reach higher impact more efficiently.
Collapse
Affiliation(s)
- E Dall'Ara
- Department of Oncology and Metabolism, Mellanby Centre for Bone Research, University of Sheffield, UK; INSIGNEO Institute for in Silico Medicine, University of Sheffield, UK.
| | | | - H Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - G Tozzi
- School of Engineering, London South Bank University, London, UK
| |
Collapse
|
24
|
Törnquist E, Le Cann S, Tengattini A, Helfen L, Kok J, Hall SA, Isaksson H. The Hydration State of Bone Tissue Affects Contrast in Neutron Tomographic Images. Front Bioeng Biotechnol 2022; 10:911866. [PMID: 35782510 PMCID: PMC9247154 DOI: 10.3389/fbioe.2022.911866] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Accepted: 05/24/2022] [Indexed: 12/25/2022] Open
Abstract
Neutron tomography has emerged as a promising imaging technique for specific applications in bone research. Neutrons have a strong interaction with hydrogen, which is abundant in biological tissues, and they can penetrate through dense materials such as metallic implants. However, in addition to long imaging times, two factors have led to challenges in running in situ mechanical characterization experiments on bone tissue using neutron tomography: 1) the high water content in specimens reduces the visibility of internal trabecular structures; 2) the mechanical properties of bone are dependent on the hydration state of the tissue, with drying being reported to cause increased stiffness and brittleness. This study investigates the possibility of improving image quality in terms of neutron transmission and contrast between material phases by drying and rehydrating in heavy water. Rat tibiae and trabecular bovine bone plugs were imaged with neutron tomography at different hydration states and mechanical testing of the bone plugs was carried out to assess effects of drying and rehydration on the mechanical properties of bone. From analysis of image histograms, it was found that drying reduced the contrast between bone and soft tissue, but the contrast was restored with rehydration. Contrast-to-noise ratios and line profiles revealed that the contrast between bone tissue and background was reduced with increasing rehydration duration but remained sufficient for identifying internal structures as long as no free liquid was present inside the specimen. The mechanical analysis indicated that the proposed fluid exchange protocol had no adverse effects on the mechanical properties.
Collapse
Affiliation(s)
- Elin Törnquist
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Sophie Le Cann
- CNRS, Université Paris Est Créteil, Université Gustave Eiffel, UMR 8208, MSME, F-94010, Créteil, France
| | - Alessandro Tengattini
- Institut Laue-Langevin, Grenoble, France
- Université Grenoble Alpes, CNRS, Grenoble INP 3SR, Grenoble, France
| | | | - Joeri Kok
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | | | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
- *Correspondence: Hanna Isaksson,
| |
Collapse
|
25
|
Axelsson R, Tomic H, Zackrisson S, Tingberg A, Isaksson H, Bakic PR, Dustler M. Finite element model of mechanical imaging of the breast. J Med Imaging (Bellingham) 2022; 9:033502. [PMID: 35647217 PMCID: PMC9125329 DOI: 10.1117/1.jmi.9.3.033502] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 05/02/2022] [Indexed: 03/20/2024] Open
Abstract
Purpose: Malignant breast lesions can be distinguished from benign lesions by their mechanical properties. This has been utilized for mechanical imaging in which the stress distribution over the breast is measured. Mechanical imaging has shown the ability to identify benign or normal cases and to reduce the number of false positives from mammography screening. Our aim was to develop a model of mechanical imaging acquisition for simulation purposes. To that end, we simulated mammographic compression of a computer model of breast anatomy and lesions. Approach: The breast compression was modeled using the finite element method. Two finite element breast models of different sizes were used and solved using linear elastic material properties in open-source virtual clinical trial (VCT) software. A spherical lesion (15 mm in diameter) was inserted into the breasts, and both the location and stiffness of the lesion were varied extensively. The average stress over the breast and the average stress at the lesion location, as well as the relative mean pressure over lesion area (RMPA), were calculated. Results: The average stress varied 6.2-6.5 kPa over the breast surface and 7.8-11.4 kPa over the lesion, for different lesion locations and stiffnesses. These stresses correspond to an RMPA of 0.80 to 1.46. The average stress was 20% to 50% higher at the lesion location compared with the average stress over the entire breast surface. Conclusions: The average stress over the breast and the lesion location corresponded well to clinical measurements. The proposed model can be used in VCTs for evaluation and optimization of mechanical imaging screening strategies.
Collapse
Affiliation(s)
- Rebecca Axelsson
- Lund University, Skåne University Hospital, Medical Radiation Physics, Department of Translational Medicine, Malmö, Sweden
- Lund University, Skåne University Hospital, Diagnostic Radiology, Department of Translational Medicine, Department in Imaging and Functional Medicine, Malmö, Sweden
| | - Hanna Tomic
- Lund University, Skåne University Hospital, Medical Radiation Physics, Department of Translational Medicine, Malmö, Sweden
| | - Sophia Zackrisson
- Lund University, Skåne University Hospital, Diagnostic Radiology, Department of Translational Medicine, Department in Imaging and Functional Medicine, Malmö, Sweden
| | - Anders Tingberg
- Lund University, Skåne University Hospital, Medical Radiation Physics, Department of Translational Medicine, Malmö, Sweden
| | - Hanna Isaksson
- Lund University, Department of Biomedical Engineering, Lund, Sweden
| | - Predrag R. Bakic
- Lund University, Skåne University Hospital, Medical Radiation Physics, Department of Translational Medicine, Malmö, Sweden
- Lund University, Skåne University Hospital, Diagnostic Radiology, Department of Translational Medicine, Department in Imaging and Functional Medicine, Malmö, Sweden
- University of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania, United States
| | - Magnus Dustler
- Lund University, Skåne University Hospital, Medical Radiation Physics, Department of Translational Medicine, Malmö, Sweden
- Lund University, Skåne University Hospital, Diagnostic Radiology, Department of Translational Medicine, Department in Imaging and Functional Medicine, Malmö, Sweden
| |
Collapse
|
26
|
Orozco GA, Tanska P, Gustafsson A, Korhonen RK, Isaksson H. Crack propagation in articular cartilage under cyclic loading using cohesive finite element modeling. J Mech Behav Biomed Mater 2022; 131:105227. [DOI: 10.1016/j.jmbbm.2022.105227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 03/01/2022] [Accepted: 04/02/2022] [Indexed: 11/28/2022]
|
27
|
Raina DB, Markevičiūtė V, Stravinskas M, Kok J, Jacobson I, Liu Y, Sezgin EA, Isaksson H, Zwingenberger S, Tägil M, Tarasevičius Š, Lidgren L. A New Augmentation Method for Improved Screw Fixation in Fragile Bone. Front Bioeng Biotechnol 2022; 10:816250. [PMID: 35309986 PMCID: PMC8926351 DOI: 10.3389/fbioe.2022.816250] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 01/31/2022] [Indexed: 11/21/2022] Open
Abstract
Pertrochanteric fractures (TF) due to osteoporosis constitute nearly half of all proximal femur fractures. TFs are treated with a surgical approach and fracture fixation is achieved using metallic fixation devices. Poor quality cancellous bone in osteoporotic patients makes anchorage of a fixation device challenging, which can lead to failure of the fracture fixation. Methods to reinforce the bone-implant interface using bone cement (PMMA) and other calcium phosphate cements in TFs have been described earlier but a clear evidence on the advantage of using such biomaterials for augmentation is weak. Furthermore, there is no standardized technique for delivering these biomaterials at the bone-implant interface. In this study, we firstly describe a method to deliver a calcium sulphate/hydroxyapatite (CaS/HA) based biomaterial for the augmentation of a lag-screw commonly used for TF fixation. We then used an osteoporotic Sawbones model to study the consequence of CaS/HA augmentation on the immediate mechanical anchorage of the lag-screw to osteoporotic bone. Finally, as a proof-of-concept, the method of delivering the CaS/HA biomaterial at the bone-implant interface as well as spreading of the CaS/HA material at this interface was tested in patients undergoing treatment for TF as well as in donated femoral heads. The mechanical testing results indicated that the CaS/HA based biomaterial increased the peak extraction force of the lag-screw by 4 times compared with un-augmented lag-screws and the results were at par with PMMA. The X-ray images from the patient series showed that it was possible to inject the CaS/HA material at the bone-implant interface without applying additional pressure and the CaS/HA material spreading was observed at the interface of the lag-screw threads and the bone. Finally, the spreading of the CaS/HA material was also verified on donated femoral heads and micro-CT imaging indicated that the entire length of the lag-screw threads was covered with the CaS/HA biomaterial. In conclusion, we present a novel method for augmenting a lag-screw in TFs, which could potentially reduce the risk of fracture fixation failure and reoperation in fragile osteoporotic patients.
Collapse
Affiliation(s)
- Deepak Bushan Raina
- Department of Clinical Sciences Lund, Orthopedics, The Faculty of Medicine, Lund University, Lund, Sweden
- *Correspondence: Deepak Bushan Raina,
| | - Vetra Markevičiūtė
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Mindaugas Stravinskas
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Joeri Kok
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Ida Jacobson
- Department of Clinical Sciences Lund, Orthopedics, The Faculty of Medicine, Lund University, Lund, Sweden
| | - Yang Liu
- Department of Clinical Sciences Lund, Orthopedics, The Faculty of Medicine, Lund University, Lund, Sweden
| | - Erdem Aras Sezgin
- Department of Orthopedics and Traumatology, Faculty of Medicine, Aksaray University, Aksaray, Turkey
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Stefan Zwingenberger
- University Hospital Carl Gustav Carus at Technische Universität Dresden, University Center of Orthopedic, Trauma and Plastic Surgery, Dresden, Germany
| | - Magnus Tägil
- Department of Clinical Sciences Lund, Orthopedics, The Faculty of Medicine, Lund University, Lund, Sweden
| | - Šarūnas Tarasevičius
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Lars Lidgren
- Department of Clinical Sciences Lund, Orthopedics, The Faculty of Medicine, Lund University, Lund, Sweden
| |
Collapse
|
28
|
Kok J, Törnquist E, Raina DB, Le Cann S, Novak V, Širka A, Lidgren L, Grassi L, Isaksson H. Fracture behavior of a composite of bone and calcium sulfate/hydroxyapatite. J Mech Behav Biomed Mater 2022; 130:105201. [DOI: 10.1016/j.jmbbm.2022.105201] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 03/19/2022] [Accepted: 03/25/2022] [Indexed: 12/12/2022]
|
29
|
Liu Y, Nadeem A, Sebastian S, Olsson MA, Wai SN, Styring E, Engellau J, Isaksson H, Tägil M, Lidgren L, Raina DB. Bone mineral: A trojan horse for bone cancers efficient mitochondria targeted delivery and tumor eradication with nano hydroxyapatite containing doxorubicin. Mater Today Bio 2022; 14:100227. [PMID: 35265825 PMCID: PMC8898975 DOI: 10.1016/j.mtbio.2022.100227] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2021] [Revised: 02/23/2022] [Accepted: 02/25/2022] [Indexed: 11/04/2022] Open
Abstract
Efficient systemic pharmacological treatment of solid tumors is hampered by inadequate tumor concentration of cytostatics necessitating development of smart local drug delivery systems. To overcome this, we demonstrate that doxorubicin (DOX), a cornerstone drug used for osteosarcoma treatment, shows reversible accretion to hydroxyapatite (HA) of both nano (nHA) and micro (mHA) size. nHA particles functionalized with DOX get engulfed in the lysosome of osteosarcoma cells where the acidic microenvironment causes a disruption of the binding between DOX and HA. The released DOX then accumulates in the mitochondria causing cell starvation, reduced migration and apoptosis. The HA+DOX delivery system was also tested in-vivo on osteosarcoma bearing mice. Locally delivered DOX via the HA particles had a stronger tumor eradication effect compared to the controls as seen by PET-CT and immunohistochemical staining of proliferation and apoptosis markers. These results indicate that in addition to systemic chemotherapy, an adjuvant nHA could be used as a carrier for intracellular delivery of DOX for prevention of tumor recurrence after surgical resection in an osteosarcoma. Furthermore, we demonstrate that nHA particles are pivotal in this approach but a combination of nHA with mHA could increase the safety associated with particulate nanomaterials while maintaining similar therapeutic potential.
Collapse
|
30
|
Williams JA, Huesa C, Turunen MJ, Oo JA, Radzins O, Gardner W, Windmill JF, Isaksson H, Tanner KE, Riddell JS, Coupaud S. Time course changes to structural, mechanical and material properties of bone in rats after complete spinal cord injury. J Musculoskelet Neuronal Interact 2022; 22:212-234. [PMID: 35642701 PMCID: PMC9186457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVE Characterise the spatiotemporal trabecular and cortical bone responses to complete spinal cord injury (SCI) in young rats. METHODS 8-week-old male Wistar rats received T9-transection SCI and were euthanised 2-, 6-, 10- or 16-weeks post-surgery. Outcome measures were assessed using micro-computed tomography, mechanical testing, serum markers and Fourier-transform infrared spectroscopy. RESULTS The trabecular and cortical bone responses to SCI are site-specific. Metaphyseal trabecular BV/TV was 59% lower, characterised by fewer and thinner trabeculae at 2-weeks post-SCI, while epiphyseal BV/TV was 23% lower with maintained connectivity. At later-time points, metaphyseal BV/TV remained unchanged, while epiphyseal BV/TV increased. The total area of metaphyseal and mid-diaphyseal cortical bone were lower from 2-weeks and between 6- and 10-weeks post-SCI, respectively. This suggested that SCI-induced bone changes observed in the rat model were not solely attributable to bone loss, but also to suppressed bone growth. No tissue mineral density differences were observed at any time-point, suggesting that decreased whole-bone mechanical properties were primarily the result of changes to the spatial distribution of bone. CONCLUSION Young SCI rat trabecular bone changes resemble those observed clinically in adult and paediatric SCI, while cortical bone changes resemble paediatric SCI only.
Collapse
Affiliation(s)
- Jonathan A. Williams
- Department of Biomedical Engineering, Wolfson Building, University of Strathclyde, Glasgow, UK,Corresponding author: Jonathan Anthony Williams, Department of Biomedical Engineering, Wolfson Building, University of Strathclyde, 106 Rottenrow East, Glasgow, G4 0NW, United Kingdom ORCiD number 0000-0002-9828-4886 E-mail:
| | - Carmen Huesa
- Centre for Musculoskeletal Science, University of the West of Scotland, Paisley, UK
| | - Mikael J. Turunen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - James A. Oo
- Institute of Neuroscience and Psychology, College of Medical, Veterinary and Life Sciences, University of Glasgow, UK,Now at Institute for Cardiovascular Physiology, Goethe University, Frankfurt am Main, Germany
| | - Oskars Radzins
- Biomedical Engineering Division, James Watt School of Engineering, James Watt South Building University of Glasgow, Glasgow, UK,Now at Department of Orthodontics, Institute of Stomatology, Riga Stradins University, Latvia
| | - Wilf Gardner
- Institute of Neuroscience and Psychology, College of Medical, Veterinary and Life Sciences, University of Glasgow, UK
| | - James F.C. Windmill
- Department of Electronic and Electrical Engineering, Royal College Building, University of Strathclyde, Glasgow, UK
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Sweden
| | - K. Elizabeth Tanner
- Biomedical Engineering Division, James Watt School of Engineering, James Watt South Building University of Glasgow, Glasgow, UK,Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Sweden,Now at School of Engineering and Materials Science and Institute of Bioengineering, Queen Mary University of London, Mile End Road, London, UK
| | - John S. Riddell
- Institute of Neuroscience and Psychology, College of Medical, Veterinary and Life Sciences, University of Glasgow, UK
| | - Sylvie Coupaud
- Department of Biomedical Engineering, Wolfson Building, University of Strathclyde, Glasgow, UK
| |
Collapse
|
31
|
Abstract
PURPOSE OF REVIEW Statistical models of shape and appearance have increased their popularity since the 1990s and are today highly prevalent in the field of medical image analysis. In this article, we review the recent literature about how statistical models have been applied in the context of osteoporosis and fracture risk estimation. RECENT FINDINGS Recent developments have increased their ability to accurately segment bones, as well as to perform 3D reconstruction and classify bone anatomies, all features of high interest in the field of osteoporosis and fragility fractures diagnosis, prevention, and treatment. An increasing number of studies used statistical models to estimate fracture risk in retrospective case-control cohorts, which is a promising step towards future clinical application. All the reviewed application areas made considerable steps forward in the past 5-6 years. Heterogeneities in validation hinder a thorough comparison between the different methods and represent one of the future challenges to be addressed to reach clinical implementation.
Collapse
Affiliation(s)
- Lorenzo Grassi
- Department of Biomedical Engineering, Lund University, Box 118, 221 00, Lund, Sweden.
| | - Sami P Väänänen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, 221 00, Lund, Sweden
| |
Collapse
|
32
|
Sezgin EA, Tor AT, Markevičiūtė V, Širka A, Tarasevičius Š, Raina DB, Liu Y, Isaksson H, Tägil M, Lidgren L. A combined fracture and mortality risk index useful for treatment stratification in hip fragility fractures. Jt Dis Relat Surg 2021; 32:583-589. [PMID: 34842088 PMCID: PMC8650669 DOI: 10.52312/jdrs.2021.382] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 09/20/2021] [Indexed: 02/06/2023] Open
Abstract
Objectives
In this study, we aimed to assess the stratification ability of the Fracture and Mortality Risk Evaluation (FAME) index for reoperation, new fragility fracture, and mortality during one-year follow-up. Patients and methods
Between November 2018 and July 2019, a total of 94 consecutive hip fragility fracture patients from two centers (20 males, 74 females; mean age: 79.3±8.9 years; range, 57 to 100 years) were retrospectively analyzed. The patients were classified into high, intermediate, and low fracture and mortality risk groups according to the Fracture Risk Assessment Tool (FRAX) score and Sernbo score, respectively, as well as nine combined categories according to the FAME index. Hospital records were reviewed to identify re-fractures (reoperations, implant failure, new fragility fractures on any site) and mortality at one year following the FAME index classification. Results
Overall re-fracture and mortality rates were 20.2% and 33%, respectively. High fracture risk category (FRAX-H) was significantly associated with higher re-fracture (odds ratio [OR]: 2.9, 95% confidence interval [CI]: 1-8.2, p=0.037) and mortality rates compared to others (OR: 3.7, 95% CI: 1.5-9.3, p=0.003). The patients classified within the FRAX-H category (n=35) had different mortality rates according to their Sernbo classification; i.e., patients classified as low mortality risk (Sernbo-L) (n=17) had lower mortality rates compared to others in this group (n=18) (35.3% and 66.7%, respectively), indicating a low statistical significance (OR: 0.3, 95% CI: 0.1-1.1, p=0.063). Similarly, within patients classified in Sernbo-L category (n=64), those classified as high fracture risk (FRAX-H) (n=17) had significantly higher re-fracture rates compared to others in this group (n=47) (35.3% and 8.5%, respectively), (OR: 5.9; 95% CI: 1.4-24.5), (p=0.017). Multivariate logistic regression analyses adjusting for covariates (age, sex, length of hospital stay and BMI) yielded similar results. Conclusion
The FAME index appears to be a useful stratification tool for allocating patients in a randomized-controlled trial for augmentation of hip fragility fractures.
Collapse
Affiliation(s)
- Erdem Aras Sezgin
- Aksaray Üniversitesi Tıp Fakültesi Ortopedi ve Travmatoloji Anabilim Dalı, 68200 Aksaray, Türkiye.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Notermans T, Khayyeri H, Isaksson H. Predicting the effect of reduced load level and cell infiltration on spatio-temporal Achilles tendon healing. J Biomech 2021; 139:110853. [PMID: 34838291 DOI: 10.1016/j.jbiomech.2021.110853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 10/13/2021] [Accepted: 10/27/2021] [Indexed: 10/19/2022]
Abstract
Mechanobiology plays an important role in tendon healing. However, the relationship between mechanical loading and spatial and temporal evolution of tendon properties during healing is not well understood. This study builds on a recently presented mechanoregulatory computational framework that couples mechanobiological tendon healing to tissue production and collagen orientation. In this study, we investigated how different magnitudes of mechanical stimulation (principal strain) affect the spatio-temporal evolution of tissue production and the temporal evolution of elastic and viscoelastic mechanical parameters. Specifically, we examined the effect of cell infiltration (mimicking migration and proliferation) in the callus on the resulting tissue production by modeling production to depend on local cell density. The model predictions were carefully compared with experimental data from Achilles tendons in rats, at 1, 2 and 4 weeks of healing. In the experiments, the rat tendons had been subjected to free cage activity or reduced load levels through intramuscular botox injections. The simulations that included cell infiltration and strain-regulated collagen production predicted spatio-temporal tissue distributions and mechanical properties similarly to that observed experimentally. In addition, lack of matrix-producing cells in the tendon core during early healing may result in reduced collagen content, regardless of the daily load level. This framework is the first to computationally investigate mechanobiological mechanisms underlying spatial and temporal variations during tendon healing for various magnitudes of loading. This framework will allow further characterization of biomechanical, biological, or mechanobiological processes underlying tendon healing.
Collapse
Affiliation(s)
- Thomas Notermans
- Department of Biomedical Engineering, Lund University, BMC D13, 22184 Lund, Sweden.
| | - Hanifeh Khayyeri
- Department of Biomedical Engineering, Lund University, BMC D13, 22184 Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, BMC D13, 22184 Lund, Sweden
| |
Collapse
|
34
|
Abstract
Ruptures to tendons are common and costly, and no clinical consensus exists on the appropriate treatment and rehabilitation regimen to promote their healing as well as full recovery of functionality. Although mechanobiology is known to play an important role in tendon regeneration, the understanding of how mechano-regulated processes affect tendon healing needs further clarification. Many small-animal studies, particularly in rats and mice, have characterized the progression of healing in terms of geometrical, structural, compositional, mechanical, and cellular properties. Some of the properties are also studied under different mechanical loading regimens. The focus of this review is to summarize and generalize the information in the literature regarding spatial and temporal differentiation of tendon properties during rodent tendon healing following full-tendon transection, as well as how this is affected by altered in vivo loading regimens.
Collapse
Affiliation(s)
| | | | | | - H Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, 22100 Lund,
| |
Collapse
|
35
|
Pigeot S, Klein T, Gullotta F, Dupard SJ, Garcia Garcia A, García-García A, Prithiviraj S, Lorenzo P, Filippi M, Jaquiery C, Kouba L, Asnaghi MA, Raina DB, Dasen B, Isaksson H, Önnerfjord P, Tägil M, Bondanza A, Martin I, Bourgine PE. Manufacturing of Human Tissues as off-the-Shelf Grafts Programmed to Induce Regeneration. Adv Mater 2021; 33:e2103737. [PMID: 34486186 DOI: 10.1002/adma.202103737] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/18/2021] [Indexed: 06/13/2023]
Abstract
Design criteria for tissue-engineered materials in regenerative medicine include robust biological effectiveness, off-the-shelf availability, and scalable manufacturing under standardized conditions. For bone repair, existing strategies rely on primary autologous cells, associated with unpredictable performance, limited availability and complex logistic. Here, a conceptual shift based on the manufacturing of devitalized human hypertrophic cartilage (HyC), as cell-free material inducing bone formation by recapitulating the developmental process of endochondral ossification, is reported. The strategy relies on a customized human mesenchymal line expressing bone morphogenetic protein-2 (BMP-2), critically required for robust chondrogenesis and concomitant extracellular matrix (ECM) enrichment. Following apoptosis-driven devitalization, lyophilization, and storage, the resulting off-the-shelf cartilage tissue exhibits unprecedented osteoinductive properties, unmatched by synthetic delivery of BMP-2 or by living engineered grafts. Scalability and pre-clinical efficacy are demonstrated by bioreactor-based production and subsequent orthotopic assessment. The findings exemplify the broader paradigm of programming human cell lines as biological factory units to engineer customized ECMs, designed to activate specific regenerative processes.
Collapse
Affiliation(s)
- Sébastien Pigeot
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
- Department of Biomedical Engineering, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - Thibaut Klein
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - Fabiana Gullotta
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
- Innovative Immunotherapies Unit, Division of Immunology, Transplantation and Infectious Diseases, San Raffaele Hospital Scientific Institute, Vita-Salute San Raffaele University, Milan, 20132, Italy
| | - Steven J Dupard
- Laboratory for Cell, Tissue, and Organ Engineering, Department of Clinical Sciences, Lund University, Lund, 221 84, Sweden
- Wallenberg Center for Molecular Medicine, Lund University, Lund, 221 84, Sweden
- Stem Cell Center, Lund University, Lund, 221 84, Sweden
| | - Alejandro Garcia Garcia
- Laboratory for Cell, Tissue, and Organ Engineering, Department of Clinical Sciences, Lund University, Lund, 221 84, Sweden
- Wallenberg Center for Molecular Medicine, Lund University, Lund, 221 84, Sweden
- Stem Cell Center, Lund University, Lund, 221 84, Sweden
| | - Andres García-García
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - Sujeethkumar Prithiviraj
- Laboratory for Cell, Tissue, and Organ Engineering, Department of Clinical Sciences, Lund University, Lund, 221 84, Sweden
- Wallenberg Center for Molecular Medicine, Lund University, Lund, 221 84, Sweden
- Stem Cell Center, Lund University, Lund, 221 84, Sweden
| | - Pilar Lorenzo
- Wallenberg Center for Molecular Medicine, Lund University, Lund, 221 84, Sweden
| | - Miriam Filippi
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - Claude Jaquiery
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - Loraine Kouba
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - M Adelaide Asnaghi
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - Deepak Bushan Raina
- Department of Clinical Sciences, Orthopedics, Lund University, Lund, 221 84, Sweden
| | - Boris Dasen
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - Hanna Isaksson
- Department of Clinical Sciences, Orthopedics, Lund University, Lund, 221 84, Sweden
- Department of Biomedical Engineering, Lund University, Lund, 221 84, Sweden
| | - Patrik Önnerfjord
- Rheumatology and Molecular Skeletal Biology, Department of Clinical Sciences, Lund University, Lund, 221 84, Sweden
| | - Magnus Tägil
- Department of Clinical Sciences, Orthopedics, Lund University, Lund, 221 84, Sweden
| | - Attilio Bondanza
- Innovative Immunotherapies Unit, Division of Immunology, Transplantation and Infectious Diseases, San Raffaele Hospital Scientific Institute, Vita-Salute San Raffaele University, Milan, 20132, Italy
| | - Ivan Martin
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
- Department of Biomedical Engineering, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
| | - Paul E Bourgine
- Department of Biomedicine, University Hospital Basel, University of Basel, Basel, 4031, Switzerland
- Laboratory for Cell, Tissue, and Organ Engineering, Department of Clinical Sciences, Lund University, Lund, 221 84, Sweden
- Wallenberg Center for Molecular Medicine, Lund University, Lund, 221 84, Sweden
- Stem Cell Center, Lund University, Lund, 221 84, Sweden
| |
Collapse
|
36
|
Liu Y, Raina DB, Sebastian S, Nagesh H, Isaksson H, Engellau J, Lidgren L, Tägil M. Sustained and controlled delivery of doxorubicin from an in-situ setting biphasic hydroxyapatite carrier for local treatment of a highly proliferative human osteosarcoma. Acta Biomater 2021; 131:555-571. [PMID: 34271171 DOI: 10.1016/j.actbio.2021.07.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 07/02/2021] [Accepted: 07/07/2021] [Indexed: 12/15/2022]
Abstract
Doxorubicin (DOX) is a cornerstone drug in the treatment of osteosarcoma. However, achieving sufficient concentration in the tumor tissue after systemic administration with few side effects has been a challenge. Even with the most advanced nanotechnology approaches, less than 5% of the total administered drug gets delivered to the target site. Alternatives to increase the local concentration of DOX within the tumor using improved drug delivery methods are needed. In this study, we evaluate a clinically approved calcium sulfate/hydroxyapatite (CaS/HA) carrier, both in-vitro and in-vivo, for local, sustained and controlled delivery of DOX to improve osteosarcoma treatment. In-vitro drug release studies indicated that nearly 28% and 36% of the loaded drug was released over a period of 4-weeks at physiological pH (7.4) and acidic pH (5), respectively. About 63% of the drug had been released after 4-weeks in-vivo. The efficacy of the released drug from the CaS/HA material was verified on two human osteosarcoma cell lines MG-63 and 143B. It was demonstrated that the released drug fractions functioned the same way as the free drug without impacting its efficacy. Finally, the carrier system with DOX was assessed using two clinically relevant human osteosarcoma xenograft models. Compared to no treatment or the clinical standard of care with systemic DOX administration, the delivery of DOX using a CaS/HA biomaterial could significantly hinder tumor progression by inhibiting angiogenesis and cell proliferation. Our results indicate that a clinically approved CaS/HA biomaterial containing cytostatics could potentially be used for the local treatment of osteosarcoma. STATEMENT OF SIGNIFICANCE: The triad of doxorubicin (DOX), methotrexate and cisplatin has routinely been used for the treatment of osteosarcoma. These drugs dramatically improved the prognosis, but 45-55% of the patients respond poorly to the treatment with low 5-year survival. In the present study, we repurpose the cornerstone drug DOX by embedding it in a calcium sulfate/hydroxyapatite (CaS/HA) biomaterial, ensuring a spatio-temporal drug release and a hypothetically higher and longer lasting intra-tumoral concentration of DOX. This delivery system could dramatically hinder the progression of a highly aggressive osteosarcoma compared to systemic administration, by inhibiting angiogenesis and cell proliferation. Our data show an efficient method for supplementary osteosarcoma treatment with possible rapid translational potential due to clinically approved constituents.
Collapse
|
37
|
Pierantoni M, Silva Barreto I, Hammerman M, Verhoeven L, Törnquist E, Novak V, Mokso R, Eliasson P, Isaksson H. A quality optimization approach to image Achilles tendon microstructure by phase-contrast enhanced synchrotron micro-tomography. Sci Rep 2021; 11:17313. [PMID: 34453067 PMCID: PMC8397765 DOI: 10.1038/s41598-021-96589-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 08/06/2021] [Indexed: 12/19/2022] Open
Abstract
Achilles tendons are mechanosensitive, and their complex hierarchical structure is in part the result of the mechanical stimulation conveyed by the muscles. To fully understand how their microstructure responds to mechanical loading a non-invasive approach for 3D high resolution imaging suitable for soft tissue is required. Here we propose a protocol that can capture the complex 3D organization of the Achilles tendon microstructure, using phase-contrast enhanced synchrotron micro-tomography (SR-PhC-μCT). We investigate the effects that sample preparation and imaging conditions have on the resulting image quality, by considering four types of sample preparations and two imaging setups (sub-micrometric and micrometric final pixel sizes). The image quality is assessed using four quantitative parameters. The results show that for studying tendon collagen fibers, conventional invasive sample preparations such as fixation and embedding are not necessary or advantageous. Instead, fresh frozen samples result in high-quality images that capture the complex 3D organization of tendon fibers in conditions as close as possible to natural. The comprehensive nature of this innovative study by SR-PhC-μCT breaks ground for future studies of soft complex biological tissue in 3D with high resolution in close to natural conditions, which could be further used for in situ characterization of how soft tissue responds to mechanical stimuli on a microscopic level.
Collapse
Affiliation(s)
- Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Box 118, 221 00, Lund, Sweden.
| | | | - Malin Hammerman
- Department of Biomedical Engineering, Lund University, Box 118, 221 00, Lund, Sweden
- Department of Biomedical and Clinical Sciences, Linköping University, 581 83, Linköping, Sweden
| | - Lissa Verhoeven
- Department of Biomedical Engineering, Lund University, Box 118, 221 00, Lund, Sweden
| | - Elin Törnquist
- Department of Biomedical Engineering, Lund University, Box 118, 221 00, Lund, Sweden
| | - Vladimir Novak
- Swiss Light Source, Paul Scherrer Institute, 5232, Villigen, Switzerland
| | - Rajmund Mokso
- Swiss Light Source, Paul Scherrer Institute, 5232, Villigen, Switzerland
- Division of Solid Mechanics, Lund University, Box 118, 221 00, Lund, Sweden
| | - Pernilla Eliasson
- Department of Biomedical and Clinical Sciences, Linköping University, 581 83, Linköping, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, 221 00, Lund, Sweden
| |
Collapse
|
38
|
Törnquist E, Le Cann S, Tudisco E, Tengattini A, Andò E, Lenoir N, Hektor J, Raina DB, Tägil M, Hall SA, Isaksson H. Dual modality neutron and x-ray tomography for enhanced image analysis of the bone-metal interface. Phys Med Biol 2021; 66. [PMID: 34010812 DOI: 10.1088/1361-6560/ac02d4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 05/19/2021] [Indexed: 11/11/2022]
Abstract
The bone tissue formed at the contact interface with metallic implants, particularly its 3D microstructure, plays a pivotal role for the structural integrity of implant fixation. X-ray tomography is the classical imaging technique used for accessing microstructural information from bone tissue. However, neutron tomography has shown promise for visualising the immediate bone-metal implant interface, something which is highly challenging with x-rays due to large differences in attenuation between metal and biological tissue causing image artefacts. To highlight and explore the complementary nature of neutron and x-ray tomography, proximal rat tibiae with titanium-based implants were imaged with both modalities. The two techniques were compared in terms of visualisation of different material phases and by comparing the properties of the individual images, such as the contrast-to-noise ratio. After superimposing the images using a dedicated image registration algorithm, the complementarity was further investigated via analysis of the dual modality histogram, joining the neutron and x-ray data. From these joint histograms, peaks with well-defined grey value intervals corresponding to the different material phases observed in the specimens were identified and compared. The results highlight differences in how neutrons and x-rays interact with biological tissues and metallic implants, as well as the benefits of combining both modalities. Future refinement of the joint histogram analysis could improve the segmentation of structures and tissues, and yield novel information about specimen-specific properties such as moisture content.
Collapse
Affiliation(s)
- Elin Törnquist
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Sophie Le Cann
- Department of Biomedical Engineering, Lund University, Lund, Sweden.,MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, Creteil, France
| | - Erika Tudisco
- Division of Geotechnical Engineering, Lund University, Lund, Sweden
| | - Alessandro Tengattini
- Institut Laue-Langevin (ILL), Grenoble, France.,Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, Grenoble, France
| | - Edward Andò
- Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, Grenoble, France
| | - Nicolas Lenoir
- Institut Laue-Langevin (ILL), Grenoble, France.,Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, Grenoble, France
| | - Johan Hektor
- LUNARC-Centre for Scientific and Technical Computing at Lund University, Lund University, Lund, Sweden
| | - Deepak Bushan Raina
- Orthopaedics, Department of Clinical Sciences, Lund, Lund University, Lund, Sweden
| | - Magnus Tägil
- Orthopaedics, Department of Clinical Sciences, Lund, Lund University, Lund, Sweden
| | - Stephen A Hall
- Division of Solid Mechanics, Lund University, Lund, Sweden.,Lund Institute of Advanced Neutron and X-ray Science (LINXS), Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden.,Orthopaedics, Department of Clinical Sciences, Lund, Lund University, Lund, Sweden
| |
Collapse
|
39
|
Kok J, Širka A, Liu Y, Tarasevičius Š, Belickas J, Tägil M, Lidgren L, Isaksson H, Raina DB. Augmenting a dynamic hip screw with a calcium sulfate/hydroxyapatite biomaterial. Med Eng Phys 2021; 92:102-109. [PMID: 34167704 DOI: 10.1016/j.medengphy.2021.05.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 04/30/2021] [Accepted: 05/09/2021] [Indexed: 11/28/2022]
Abstract
Internal fixation failure in hip fractures can lead to reoperation. Calcium sulfate/hydroxyapatite (CaS/HA) is a biomaterial that can be used for augmenting fracture fixation. We aimed to determine whether an injection of 2 ml CaS/HA increases the fixation of a dynamic hip screw inserted in synthetic and human trabecular bone. The study consists of two parts: 1) synthetic bone blocks (n = 74), with three subgroups: empty (cannulated screw, no injection), cannulated, and fenestrated; and 2) osteoporotic human femoral heads (n = 29), with the same subgroups. The heads were imaged using µCT. Bone volume fraction, insertion angle, and head diameter were measured. Pullout tests were performed and peak force, stiffness, and work were measured. The fenestrated group showed increases in pullout strength compared to no injection in the synthetic blocks. The cannulated group showed a higher pullout strength in low-density blocks. In the femoral heads, the variation was larger and there were no significant differences between groups. The bone volume fraction correlated with the peak force and work, and the insertion angle correlated with the stiffness. CaS/HA can improve the fixation of a dynamic hip screw. For clinical use, spreading of the material around the threads of the screw must be ensured.
Collapse
Affiliation(s)
- Joeri Kok
- Department of Biomedical Engineering, Lund University, Box 118, 22100 Lund, Sweden.
| | - Aurimas Širka
- Department of Orthopedics and Traumatology, Hospital of Lithuanian University of Health Sciences Kaunas Clinics, Eiveniu ave.2, Kaunas, Lithuania.
| | - Yang Liu
- Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| | - Šarūnas Tarasevičius
- Department of Orthopedics and Traumatology, Hospital of Lithuanian University of Health Sciences Kaunas Clinics, Eiveniu ave.2, Kaunas, Lithuania.
| | - Juozas Belickas
- Department of Orthopedics and Traumatology, Hospital of Lithuanian University of Health Sciences Kaunas Clinics, Eiveniu ave.2, Kaunas, Lithuania.
| | - Magnus Tägil
- Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| | - Lars Lidgren
- Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, 22100 Lund, Sweden; Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| | - Deepak Bushan Raina
- Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| |
Collapse
|
40
|
Guillaume F, Le Cann S, Tengattini A, Törnquist E, Falentin-Daudre C, Albini Lomami H, Petit Y, Isaksson H, Haïat G. Neutron microtomography to investigate the bone-implant interface-comparison with histological analysis. Phys Med Biol 2021; 66. [PMID: 33831846 DOI: 10.1088/1361-6560/abf603] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 04/08/2021] [Indexed: 12/20/2022]
Abstract
Bone properties and especially its microstructure around implants are crucial to evaluate the osseointegration of prostheses in orthopaedic, maxillofacial and dental surgeries. Given the intrinsic heterogeneous nature of the bone microstructure, an ideal probing tool to understand and quantify bone formation must be spatially resolved. X-ray imaging has often been employed, but is limited in the presence of metallic implants, where severe artifacts generally arise from the high attenuation of metals to x-rays. Neutron tomography has recently been proposed as a promising technique to study bone-implant interfaces, thanks to its lower interaction with metals. The aim of this study is to assess the potential of neutron tomography for the characterisation of bone tissue in the vicinity of a metallic implant. A standardised implant with a bone chamber was implanted in rabbit bone. Four specimens were imaged with neutron tomography and subsequently compared to non-decalcified histology to stain soft and mineralised bone tissues, used here as a ground-truth reference. An intensity-based image registration procedure was performed to place the 12 histological slices within the corresponding 3D neutron volume. Significant correlations (p < 0.01) were obtained between the two modalities for the bone-implant contact (BIC) ratio (R = 0.77) and the bone content inside the chamber (R = 0.89). The results indicate that mineralised bone tissue can be reliably detected by neutron tomography. However, theBICratio and bone content were found to be overestimated with neutron imaging, which may be explained by its sensitivity to non-mineralised soft tissues, as revealed by histological staining. This study highlights the suitability of neutron tomography for the analysis of the bone-implant interface. Future work will focus on further distinguishing soft tissues from bone tissue, which could be aided by the adoption of contrast agents.
Collapse
Affiliation(s)
- Florian Guillaume
- Département de génie mécanique, École de technologie supérieure, Montréal, Canada.,MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, F-94010 Creteil, France
| | - Sophie Le Cann
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, F-94010 Creteil, France
| | - Alessandro Tengattini
- Institut Laue Langevin, Grenoble, France.,Laboratoire 3SR, Université Grenoble Alpes, Gières, France
| | - Elin Törnquist
- Department of Biomedical Engineering, Lund University, SE-221 00 Lund, Sweden
| | - Céline Falentin-Daudre
- LBPS/CSPBAT, UMR CNRS 7244, Institut Galilée, Université Sorbonne Paris Nord, 99 avenue JB Clément 93430- Villetaneuse, France
| | - Hugues Albini Lomami
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, F-94010 Creteil, France
| | - Yvan Petit
- Département de génie mécanique, École de technologie supérieure, Montréal, Canada
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, SE-221 00 Lund, Sweden
| | - Guillaume Haïat
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, F-94010 Creteil, France
| |
Collapse
|
41
|
Kok J, Grassi L, Gustafsson A, Isaksson H. Femoral strength and strains in sideways fall: Validation of finite element models against bilateral strain measurements. J Biomech 2021; 122:110445. [PMID: 33933857 DOI: 10.1016/j.jbiomech.2021.110445] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 02/15/2021] [Accepted: 04/12/2021] [Indexed: 11/29/2022]
Abstract
Low impact falls to the side are the main cause of hip fractures in elderly. Finite element (FE) models of the proximal femur may help in the assessment of patients at high risk for a hip fracture. However, extensive validation is essential before these models can be used in a clinical setting. This study aims to use strain measurements from bilateral digital image correlation to validate an FE model against ex vivo experimental data of proximal femora under a sideways fall loading condition. For twelve subjects, full-field strain measurements were available on the medial and lateral side of the femoral neck. In this study, subject-specific FE models were generated based on a consolidated procedure previously validated for stance loading. The material description included strain rate dependency and separate yield and fracture strain limits in tension and compression. FE predicted fracture force and experimentally measured peak forces showed a strong correlation (R2 = 0.92). The FE simulations predicted the fracture initiation within 3 mm distance of the experimental fracture line for 8/12 subjects. The predicted and measured strains correlated well on both the medial side (R2 = 0.87) and the lateral side (R2 = 0.74). The lower correlation on the lateral side is attributed to the irregularity of the cortex and presence of vessel holes in this region. The combined validation against bilateral full-field strain measurements and peak forces has opened the door for a more elaborate qualitative and quantitative validation of FE models of femora under sideways fall loading.
Collapse
Affiliation(s)
- Joeri Kok
- Department of Biomedical Engineering, Lund University, Sweden.
| | - Lorenzo Grassi
- Department of Biomedical Engineering, Lund University, Sweden
| | - Anna Gustafsson
- Department of Biomedical Engineering, Lund University, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Sweden
| |
Collapse
|
42
|
Pierantoni M, Le Cann S, Sotiriou V, Ahmed S, Bodey AJ, Jerjen I, Nowlan NC, Isaksson H. Muscular loading affects the 3D structure of both the mineralized rudiment and growth plate at early stages of bone formation. Bone 2021; 145:115849. [PMID: 33454374 DOI: 10.1016/j.bone.2021.115849] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 01/13/2021] [Accepted: 01/13/2021] [Indexed: 11/25/2022]
Abstract
Fetal immobilization affects skeletal development and can lead to severe malformations. Still, how mechanical load affects embryonic bone formation is not fully elucidated. This study combines mechanobiology, image analysis and developmental biology, to investigate the structural effects of muscular loading on embryonic long bones. We present a novel approach involving a semi-automatic workflow, to study the spatial and temporal evolutions of both hard and soft tissues in 3D without any contrast agent at micrometrical resolution. Using high-resolution phase-contrast-enhanced X-ray synchrotron microtomography, we compare the humeri of Splotch-delayed embryonic mice lacking skeletal muscles with healthy littermates. The effects of skeletal muscles on bone formation was studied from the first stages of mineral deposition (Theiler Stages 23 and 24) to just before birth (Theiler Stage 27). The results show that muscle activity affects both growth plate and mineralized regions, especially during early embryonic development. When skeletal muscles were absent, there was reduced mineralization, altered tuberosity size and location, and, at early embryonic stages, decreased chondrocyte density, size and elongation compared to littermate controls. The proposed workflow enhances our understanding of mechanobiology of early bone formation and could be implemented for the study of other complex biological tissues.
Collapse
Affiliation(s)
- Maria Pierantoni
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden.
| | - Sophie Le Cann
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden
| | - Vivien Sotiriou
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | - Saima Ahmed
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | | | - Iwan Jerjen
- Swiss Light Source, Paul Scherrer Institute, Villigen, Switzerland
| | - Niamh C Nowlan
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden
| |
Collapse
|
43
|
Notermans T, Tanska P, Korhonen RK, Khayyeri H, Isaksson H. A numerical framework for mechano-regulated tendon healing-Simulation of early regeneration of the Achilles tendon. PLoS Comput Biol 2021; 17:e1008636. [PMID: 33556080 PMCID: PMC7901741 DOI: 10.1371/journal.pcbi.1008636] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 02/23/2021] [Accepted: 12/15/2020] [Indexed: 12/19/2022] Open
Abstract
Mechano-regulation during tendon healing, i.e. the relationship between mechanical stimuli and cellular response, has received more attention recently. However, the basic mechanobiological mechanisms governing tendon healing after a rupture are still not well-understood. Literature has reported spatial and temporal variations in the healing of ruptured tendon tissue. In this study, we explored a computational modeling approach to describe tendon healing. In particular, a novel 3D mechano-regulatory framework was developed to investigate spatio-temporal evolution of collagen content and orientation, and temporal evolution of tendon stiffness during early tendon healing. Based on an extensive literature search, two possible relationships were proposed to connect levels of mechanical stimuli to collagen production. Since literature remains unclear on strain-dependent collagen production at high levels of strain, the two investigated production laws explored the presence or absence of collagen production upon non-physiologically high levels of strain (>15%). Implementation in a finite element framework, pointed to large spatial variations in strain magnitudes within the callus tissue, which resulted in predictions of distinct spatial distributions of collagen over time. The simulations showed that the magnitude of strain was highest in the tendon core along the central axis, and decreased towards the outer periphery. Consequently, decreased levels of collagen production for high levels of tensile strain were shown to accurately predict the experimentally observed delayed collagen production in the tendon core. In addition, our healing framework predicted evolution of collagen orientation towards alignment with the tendon axis and the overall predicted tendon stiffness agreed well with experimental data. In this study, we explored the capability of a numerical model to describe spatial and temporal variations in tendon healing and we identified that understanding mechano-regulated collagen production can play a key role in explaining heterogeneities observed during tendon healing.
Collapse
Affiliation(s)
- Thomas Notermans
- Department of Biomedical Engineering, Lund University, Lund, Sweden
- * E-mail:
| | - Petri Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Rami K. Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Hanifeh Khayyeri
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| |
Collapse
|
44
|
Grassi L, Fleps I, Sahlstedt H, Väänänen SP, Ferguson SJ, Isaksson H, Helgason B. Validation of 3D finite element models from simulated DXA images for biofidelic simulations of sideways fall impact to the hip. Bone 2021; 142:115678. [PMID: 33022451 DOI: 10.1016/j.bone.2020.115678] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 09/11/2020] [Accepted: 09/30/2020] [Indexed: 10/23/2022]
Abstract
Computed tomography (CT)-derived finite element (FE) models have been proposed as a tool to improve the current clinical assessment of osteoporosis and personalized hip fracture risk by providing an accurate estimate of femoral strength. However, this solution has two main drawbacks, namely: (i) 3D CT images are needed, whereas 2D dual-energy x-ray absorptiometry (DXA) images are more generally available, and (ii) quasi-static femoral strength is predicted as a surrogate for fracture risk, instead of predicting whether a fall would result in a fracture or not. The aim of this study was to combine a biofidelic fall simulation technique, based on 3D computed tomography (CT) data with an algorithm that reconstructs 3D femoral shape and BMD distribution from a 2D DXA image. This approach was evaluated on 11 pelvis-femur constructs for which CT scans, ex vivo sideways fall impact experiments and CT-derived biofidelic FE models were available. Simulated DXA images were used to reconstruct the 3D shape and bone mineral density (BMD) distribution of the left femurs by registering a projection of a statistical shape and appearance model with a genetic optimization algorithm. The 2D-to-3D reconstructed femurs were meshed, and the resulting FE models inserted into a biofidelic FE modeling pipeline for simulating a sideways fall. The median 2D-to-3D reconstruction error was 1.02 mm for the shape and 0.06 g/cm3 for BMD for the 11 specimens. FE models derived from simulated DXAs predicted the outcome of the falls in terms of fracture versus non-fracture with the same accuracy as the CT-derived FE models. This study represents a milestone towards improved assessment of hip fracture risk based on widely available clinical DXA images.
Collapse
Affiliation(s)
- Lorenzo Grassi
- Department of Biomedical Engineering, Lund University, Lund, Sweden.
| | - Ingmar Fleps
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | | | - Sami P Väänänen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland; Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | | | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | | |
Collapse
|
45
|
Khayyeri H, Hammerman M, Turunen MJ, Blomgran P, Notermans T, Guizar-Sicairos M, Eliasson P, Aspenberg P, Isaksson H. Diminishing effects of mechanical loading over time during rat Achilles tendon healing. PLoS One 2020; 15:e0236681. [PMID: 33315857 PMCID: PMC7735574 DOI: 10.1371/journal.pone.0236681] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 11/23/2020] [Indexed: 01/07/2023] Open
Abstract
Mechanical loading affects tendon healing and recovery. However, our understanding about how physical loading affects recovery of viscoelastic functions, collagen production and tissue organisation is limited. The objective of this study was to investigate how different magnitudes of loading affects biomechanical and collagen properties of healing Achilles tendons over time. Achilles tendon from female Sprague Dawley rats were cut transversely and divided into two groups; normal loading (control) and reduced loading by Botox (unloading). The rats were sacrificed at 1, 2- and 4-weeks post-injury and mechanical testing (creep test and load to failure), small angle x-ray scattering (SAXS) and histological analysis were performed. The effect of unloading was primarily seen at the early time points, with inferior mechanical and collagen properties (SAXS), and reduced histological maturation of the tissue in unloaded compared to loaded tendons. However, by 4 weeks no differences remained. SAXS and histology revealed heterogeneous tissue maturation with more mature tissue at the peripheral region compared to the center of the callus. Thus, mechanical loading advances Achilles tendon biomechanical and collagen properties earlier compared to unloaded tendons, and the spatial variation in tissue maturation and collagen organization across the callus suggests important regional (mechano-) biological activities that require more investigation.
Collapse
Affiliation(s)
- Hanifeh Khayyeri
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Malin Hammerman
- Department of Biomedical Engineering, Lund University, Lund, Sweden
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Mikael J. Turunen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Parmis Blomgran
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Thomas Notermans
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | | | - Pernilla Eliasson
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Per Aspenberg
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
- * E-mail:
| |
Collapse
|
46
|
Gustafsson A, Wallin M, Isaksson H. The influence of microstructure on crack propagation in cortical bone at the mesoscale. J Biomech 2020; 112:110020. [PMID: 32980752 DOI: 10.1016/j.jbiomech.2020.110020] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 05/26/2020] [Accepted: 08/26/2020] [Indexed: 10/23/2022]
Abstract
The microstructure of cortical bone is key for the tissue's high toughness and strength and efficient toughening mechanisms have been identified at the microscale, for example when propagating cracks interact with the osteonal microstructure. Finite element models have been proposed as suitable tools for analyzing the complex link between the local tissue structure and the fracture resistance of cortical bone. However, previous models that could capture realistic crack paths in cortical bone were due to the required computational effort limited to idealized osteon geometries and small (<1 mm2) model domains. The objective of this study was therefore to bridge the gap between experimental and numerical analysis of crack propagation in cortical bone by introducing image-based models at the mesoscale. Tissue orientation maps from high-resolution micro-CT images were used to define the distribution and orientation of weak interfaces in the models. Crack propagation was simulated using the extended finite element method in combination with an interface damage model, previously developed to simulate crack propagation in microstructural osteon models. The results showed that image-based mesoscale models can be used to capture interactions between cracks and microstructure. The simulated crack paths predicted the general trends seen in experiments with more irregular patterns for cracks propagating perpendicular compared to parallel to the osteon orientation. In all, the proposed method enabled an efficient description of the tissue level microstructure, which is a necessity to predict realistic crack paths in cortical bone and is an important step towards simulating crack propagation in bone models in 3D.
Collapse
Affiliation(s)
- Anna Gustafsson
- Department of Biomedical Engineering, Lund University, Box 118, SE-221 00 Lund, Sweden.
| | - Mathias Wallin
- Division of Solid Mechanics, Lund University, Box 118, SE-221 00 Lund, Sweden.
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, SE-221 00 Lund, Sweden.
| |
Collapse
|
47
|
Silva Barreto I, Le Cann S, Ahmed S, Sotiriou V, Turunen MJ, Johansson U, Rodriguez‐Fernandez A, Grünewald TA, Liebi M, Nowlan NC, Isaksson H. Multiscale Characterization of Embryonic Long Bone Mineralization in Mice. Adv Sci (Weinh) 2020; 7:2002524. [PMID: 33173750 PMCID: PMC7610310 DOI: 10.1002/advs.202002524] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Indexed: 06/01/2023]
Abstract
Long bone mineralization occurs through endochondral ossification, where a cartilage template mineralizes into bone-like tissue with a hierarchical organization from the whole bone-scale down to sub-nano scale. Whereas this process has been extensively studied at the larger length scales, it remains unexplored at some of the smaller length scales. In this study, the changes in morphology, composition, and structure during embryonic mineralization of murine humeri are investigated using a range of high-resolution synchrotron-based imaging techniques at several length scales. With micro- and nanometer spatial resolution, the deposition of elements and the shaping of mineral platelets are followed. Rapid mineralization of the humeri occurs over approximately four days, where mineral to matrix ratio and calcium content in the most mineralized zone reach adult values shortly before birth. Interestingly, zinc is consistently found to be localized at the sites of ongoing new mineralization. The mineral platelets in the most recently mineralized regions are thicker, longer, narrower, and less aligned compared to those further into the mineralized region. In summary, this study demonstrates a specific spatial distribution of zinc, with highest concentration where new mineral is being deposited and that the newly formed mineral platelets undergo slight reshaping and reorganization during embryonic development.
Collapse
Affiliation(s)
| | - Sophie Le Cann
- Department of Biomedical EngineeringLund UniversityLund22100Sweden
| | - Saima Ahmed
- Department of BioengineeringImperial College LondonLondonSW72AZUK
| | - Vivien Sotiriou
- Department of BioengineeringImperial College LondonLondonSW72AZUK
| | - Mikael J. Turunen
- Department of Applied PhysicsUniversity of Eastern FinlandKuopio70211Finland
| | | | | | | | - Marianne Liebi
- Department of PhysicsChalmers University of TechnologyGothenburg41296Sweden
| | - Niamh C. Nowlan
- Department of BioengineeringImperial College LondonLondonSW72AZUK
| | - Hanna Isaksson
- Department of Biomedical EngineeringLund UniversityLund22100Sweden
| |
Collapse
|
48
|
Raina DB, Matuszewski LM, Vater C, Bolte J, Isaksson H, Lidgren L, Tägil M, Zwingenberger S. A facile one-stage treatment of critical bone defects using a calcium sulfate/hydroxyapatite biomaterial providing spatiotemporal delivery of bone morphogenic protein-2 and zoledronic acid. Sci Adv 2020; 6:6/48/eabc1779. [PMID: 33246951 PMCID: PMC7695465 DOI: 10.1126/sciadv.abc1779] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 10/09/2020] [Indexed: 05/11/2023]
Abstract
Bone morphogenic proteins (BMPs) are the only true osteoinductive molecules. Despite being tremendously potent, their clinical use has been limited for reasons including supraphysiological doses, suboptimal delivery systems, and the pro-osteoclast effect of BMPs. Efforts to achieve spatially controlled bone formation using BMPs are being made. We demonstrate that a carrier consisting of a powder of calcium sulfate/hydroxyapatite (CaS/HA) mixed with bone active molecules provides an efficient drug delivery platform for critical femoral defect healing in rats. The bone-active molecules were composed of osteoinductive rhBMP-2 and the bisphosphonate, and zoledronic acid (ZA) was chosen to overcome BMP-2-induced bone resorption. It was demonstrated that delivery of rhBMP-2 was necessary for critical defect healing and restoration of mechanical properties, but codelivery of BMP-2 and ZA led to denser and stronger fracture calluses. Together, the CaS/HA biomaterial with rhBMP-2 and/or ZA can potentially be used as an off-the-shelf alternative to autograft bone.
Collapse
Affiliation(s)
- Deepak Bushan Raina
- Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Orthopaedics, Lund 22185, Sweden.
| | - Lucas-Maximilian Matuszewski
- University Hospital Carl Gustav Carus at Technische Universität Dresden, University Center of Orthopedic, Trauma and Plastic Surgery, Dresden 01307, Germany
| | - Corina Vater
- University Hospital Carl Gustav Carus at Technische Universität Dresden, University Center of Orthopedic, Trauma and Plastic Surgery, Dresden 01307, Germany
| | - Julia Bolte
- University Hospital Carl Gustav Carus at Technische Universität Dresden, University Center of Orthopedic, Trauma and Plastic Surgery, Dresden 01307, Germany
| | - Hanna Isaksson
- Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Orthopaedics, Lund 22185, Sweden
- Lund University, Department of Biomedical Engineering, Lund 22100, Sweden
| | - Lars Lidgren
- Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Orthopaedics, Lund 22185, Sweden
| | - Magnus Tägil
- Lund University, Faculty of Medicine, Department of Clinical Sciences Lund, Orthopaedics, Lund 22185, Sweden
| | - Stefan Zwingenberger
- University Hospital Carl Gustav Carus at Technische Universität Dresden, University Center of Orthopedic, Trauma and Plastic Surgery, Dresden 01307, Germany
| |
Collapse
|
49
|
Le Cann S, Törnquist E, Silva Barreto I, Fraulob M, Albini Lomami H, Verezhak M, Guizar-Sicairos M, Isaksson H, Haïat G. Spatio-temporal evolution of hydroxyapatite crystal thickness at the bone-implant interface. Acta Biomater 2020; 116:391-399. [PMID: 32937205 DOI: 10.1016/j.actbio.2020.09.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 08/24/2020] [Accepted: 09/09/2020] [Indexed: 02/02/2023]
Abstract
A better understanding of bone nanostructure around the bone-implant interface is essential to improve longevity of clinical implants and decrease failure risks. This study investigates the spatio-temporal evolution of mineral crystal thickness and plate orientation in newly formed bone around the surface of a metallic implant. Standardized coin-shaped titanium implants designed with a bone chamber were inserted into rabbit tibiae for 7 and 13 weeks. Scanning measurements with micro-focused small-angle X-ray scattering (SAXS) were carried out on newly formed bone close to the implant and in control mature cortical bone. Mineral crystals were thinner close to the implant (1.8 ± 0.45 nm at 7 weeks and 2.4 ± 0.57 nm at 13 weeks) than in the control mature bone tissue (2.5 ± 0.21 nm at 7 weeks and 2.8 ± 0.35 nm at 13 weeks), with increasing thickness over healing time (+30 % in 6 weeks). These results are explained by younger bone close to the implant, which matures during osseointegration. Thinner mineral crystals parallel to the implant surface within the first 100 µm indicate that the implant affects the ultrastructure of neighbouring bone , potentially due to heterogeneous interfacial stresses, and suggest a longer maturation process of bone tissue and difficulty in binding to the metal. The bone growth kinetics within the bone chamber was derived from the spatio-temporal evolution of bone tissue's nanostructure, coupled with microtomographic imaging. The findings indicate that understanding mineral crystal thickness or plate orientation can improve our knowledge of osseointegration.
Collapse
Affiliation(s)
- Sophie Le Cann
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, F-94010 Creteil, France.
| | - Elin Törnquist
- Department of Biomedical Engineering, Lund University, 221 00 Lund, Sweden
| | | | - Manon Fraulob
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, F-94010 Creteil, France
| | - Hugues Albini Lomami
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, F-94010 Creteil, France
| | - Mariana Verezhak
- Paul Scherrer Institut, Forschungsstrasse 111, Villigen 5232, Switzerland
| | | | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, 221 00 Lund, Sweden
| | - Guillaume Haïat
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, F-94010 Creteil, France
| |
Collapse
|
50
|
Raina DB, Širka A, Qayoom I, Teotia AK, Liu Y, Tarasevicius S, Tanner KE, Isaksson H, Kumar A, Tägil M, Lidgren L. Long-Term Response to a Bioactive Biphasic Biomaterial in the Femoral Neck of Osteoporotic Rats. Tissue Eng Part A 2020; 26:1042-1051. [PMID: 32242474 PMCID: PMC7580608 DOI: 10.1089/ten.tea.2020.0018] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 03/27/2020] [Indexed: 11/13/2022] Open
Abstract
Osteoporosis often leads to fragility fractures of the hip, resulting in impaired quality of life and increased mortality. Augmenting the proximal femur could be an attractive option for prevention of fracture or fixation device failure. We describe a tissue engineering based strategy to enhance long-term bone formation in the femoral neck of osteoporotic rats by locally delivering bioactive molecules; recombinant human bone morphogenic protein-2 (rhBMP-2), and zoledronic acid (ZA) by using a calcium sulfate/hydroxyapatite (CaS/HA) biomaterial. A defect was created by reaming the femoral neck canal of osteoporotic (OVX) rats and they were treated as follows: G1. Empty, G2. CaS/HA, G3. CaS/HA+Systemic ZA, G4. CaS/HA+Local ZA, and G5. CaS/HA+Local ZA+rhBMP-2. Bone formation was evaluated 6 months after treatment. Further, radioactively labeled 14C-ZA was used to study the bioavailability of ZA at the defect location, which was determined by using scintillation counting. Micro-CT indicated significantly higher bone volume in groups G4 and G5 compared with the other treatment groups. This was confirmed qualitatively by histological assessment. Addition of rhBMP-2 gave no additional benefit in this model. Local delivery of ZA performed better than systemic administration of ZA. Mechanical testing showed no differences between the groups, likely reflecting that the addition of bioactive molecules had limited effect on cortical bone or the choice of mechanical testing setup was not optimal. Scintillation counting revealed higher amounts of 14C-ZA present in the treated leg of G4 compared with its contralateral control and compared with G3, indicating that local ZA delivery can be used to achieve high local concentrations without causing a systemic effect. This long-term study shows that local delivery of ZA using a CaS/HA carrier can regenerate cancellous bone in the femoral neck canal and has clear implications for enhancing implant integration and fixation in fragile bone.
Collapse
Affiliation(s)
- Deepak Bushan Raina
- Department of Clinical Sciences Lund, Orthopedics, Faculty of Medicine, Lund University, Lund, Sweden
| | - Aurimas Širka
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Irfan Qayoom
- Department of Biological Sciences and Bioengineering, Indian Institute of Technology Kanpur, Kanpur, India
| | - Arun Kumar Teotia
- Department of Biological Sciences and Bioengineering, Indian Institute of Technology Kanpur, Kanpur, India
| | - Yang Liu
- Department of Clinical Sciences Lund, Orthopedics, Faculty of Medicine, Lund University, Lund, Sweden
| | - Sarunas Tarasevicius
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Kathleen Elizabeth Tanner
- Queen Mary University of London, School of Engineering and Materials Science and Institute of Bioengineering, London, United Kingdom
| | - Hanna Isaksson
- Department of Clinical Sciences Lund, Orthopedics, Faculty of Medicine, Lund University, Lund, Sweden
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Ashok Kumar
- Department of Biological Sciences and Bioengineering, Indian Institute of Technology Kanpur, Kanpur, India
| | - Magnus Tägil
- Department of Clinical Sciences Lund, Orthopedics, Faculty of Medicine, Lund University, Lund, Sweden
| | - Lars Lidgren
- Department of Clinical Sciences Lund, Orthopedics, Faculty of Medicine, Lund University, Lund, Sweden
| |
Collapse
|