1
|
Lee JH, Kim SH, Kim JH, Baek G, Nakla A, McGarry M, Lee TQ, Shin SJ. Biomechanical Characteristics of Glenosphere Orientation Based on Tilting Angle and Overhang Changes in Reverse Shoulder Arthroplasty. Clin Orthop Surg 2024; 16:303-312. [PMID: 38562639 PMCID: PMC10973622 DOI: 10.4055/cios23217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 11/25/2023] [Accepted: 11/25/2023] [Indexed: 04/04/2024] Open
Abstract
Background Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.
Collapse
Affiliation(s)
- Jae-Hoo Lee
- Department of Orthopaedic Surgery, Inje University Ilsan Paik Hospital, Goyang, Korea
| | - Seong Hun Kim
- Department of Orthopaedic Surgery, National Health Insurance Service Ilsan Hospital, Goyang, Korea
| | - Jae Hyung Kim
- Department of Orthopaedic Surgery, Ewha Shoulder Disease Center, Ewha Womans University Seoul Hospital, Ewha Womans University School of Medicine, Seoul, Korea
| | - Gyurim Baek
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Andrew Nakla
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Michelle McGarry
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Thay Q. Lee
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Sang-Jin Shin
- Department of Orthopaedic Surgery, Ewha Shoulder Disease Center, Ewha Womans University Seoul Hospital, Ewha Womans University School of Medicine, Seoul, Korea
| |
Collapse
|
2
|
Blasco JM, Navarro-Bosch M, Aroca-Navarro JE, Hernández-Guillén D, Puigcerver-Aranda P, Roig-Casasús S. A Virtual Assistant to Guide Early Postoperative Rehabilitation after Reverse Shoulder Arthroplasty: A Pilot Randomized Trial. Bioengineering (Basel) 2024; 11:152. [PMID: 38391638 PMCID: PMC10885890 DOI: 10.3390/bioengineering11020152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 01/29/2024] [Accepted: 01/30/2024] [Indexed: 02/24/2024] Open
Abstract
INTRODUCTION Rehabilitation can improve outcomes after reverse shoulder arthroplasty (RSA). However, low adherence to rehabilitation and compliance rates are some of the main barriers. To address this public health issue, the goal of this research was to pilot test and evaluate the effectiveness of a chatbot to promote adherence to home rehabilitation in patients undergoing RSA. METHODS A randomized pilot trial including patients undergoing RSA and early postoperative rehabilitation was performed. The control group received standard home rehabilitation; the experimental group received the same intervention supervised with a chatbot, with automated interactions that included messages to inform, motivate, and remember the days and exercises for 12 weeks. Compliance with rehabilitation and clinical measures of shoulder function, pain, and quality of life were assessed. RESULTS 31 patients (17 experimental) with an average age of 70.4 (3.6) completed the intervention. Compliance was higher in the experimental group (77% vs. 65%; OR95% = 2.4 (0.5 to 11.4)). Statistically significant between-group differences with a CI of 95% were found in the QuickDASH questionnaire and self-reported quality of life. No differences were found in the rest of the measures. CONCLUSIONS This pilot study suggests that the chatbot tool can be useful in promoting compliance with early postoperative home rehabilitation in patients undergoing RSA. Future randomized trials with adequate power are warranted to determine the clinical impact of the proposal.
Collapse
Affiliation(s)
- José-María Blasco
- Group in Physiotherapy of the Ageing Processes-Social and Healthcare Strategies, Department of Physiotherapy, University of Valencia, 46010 Valencia, Spain
| | - Marta Navarro-Bosch
- Orthopedic and Trauma Surgery Service, Hospital Universitari i Politècnic La Fe de València, 46026 Valencia, Spain
| | - José-Enrique Aroca-Navarro
- Orthopedic and Trauma Surgery Service, Hospital Universitari i Politècnic La Fe de València, 46026 Valencia, Spain
| | - David Hernández-Guillén
- Group in Physiotherapy of the Ageing Processes-Social and Healthcare Strategies, Department of Physiotherapy, University of Valencia, 46010 Valencia, Spain
| | | | - Sergio Roig-Casasús
- Group in Physiotherapy of the Ageing Processes-Social and Healthcare Strategies, Department of Physiotherapy, University of Valencia, 46010 Valencia, Spain
- Orthopedic and Trauma Surgery Service, Hospital Universitari i Politècnic La Fe de València, 46026 Valencia, Spain
| |
Collapse
|
3
|
Castricini R, Mercurio M, Galasso O, Sanzo V, De Gori M, De Benedetto M, Orlando N, Gasparini G. Femoral head allograft for glenoid bone loss in primary reverse shoulder arthroplasty: functional and radiologic outcomes. J Shoulder Elbow Surg 2024; 33:e58-e67. [PMID: 37506998 DOI: 10.1016/j.jse.2023.06.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 06/05/2023] [Accepted: 06/21/2023] [Indexed: 07/30/2023]
Abstract
BACKGROUND Several techniques have been adopted during primary reverse shoulder arthroplasty (RSA) to manage glenoid bone defect. Among bone grafts, humeral head autograft is currently the mainstream option. However, autologous humeral heads may be unavailable or inadequate, and allografts may be a viable alternative. The aim of the present study was to evaluate the functional and radiologic outcomes of femoral head allografts for glenoid bone defects in primary RSA. METHODS We conducted a retrospective study with prospective data collection enrolling 20 consecutive patients who underwent RSA with femoral head allografts for glenoid bone defects. Indications for surgery were eccentric cuff tear arthropathy in 10 cases (50%), concentric osteoarthritis in 9 cases (45%), and fracture sequelae in 1 case (5%). Each patient was evaluated preoperatively and at follow-up by radiologic and computed tomography (CT) and by assessing the range of motion (ROM) and the Constant-Murley score (CMS). A CT-based software, a patient-specific 3D model of the scapula, and patient-specific instrumentation were used to shape the graft and to assess the position of K-wire for the central peg. Postoperatively, CT scans were used to identify graft incorporation and resorption. RESULTS After a median follow-up of 26.5 months (24-38), ROM and CMS showed a statistically significant improvement (all P = .001). The median measures of the graft were as follows: 28 mm (28-29) for diameter, 22° (10°-31°) for angle, 4 mm (2-8 mm) for minimum thickness, and 15 mm (11-21 mm) for maximum thickness. Before the surgery, the median glenoid version was 21.8° (16.5°-33.5°) for the retroverted glenoids and -13.5° (-23° to -12°) for the anteverted glenoids. At the follow-up, the median postoperative baseplate retroversion was 5.7° (2.2°-1.5°) (P = .001), and this value was close to the 4° retroversion planned on the preoperative CT-based software. Postoperative major complications were noted in 4 patients: 2 dislocations, 1 baseplate failure following a high-energy trauma, and 1 septic baseplate failure. Partial graft resorption without glenoid component failure was observed in 3 cases that did not require revision surgery. CONCLUSION The femoral head allograft for glenoid bone loss in primary RSA restores shoulder function, with CMS values comparable to those of sex- and age-matched healthy individuals. A high rate of incorporation of the graft and satisfactory correction of the glenoid version can be expected after surgery. The management of glenoid bone defects remains a challenging procedure, and a 15% risk of major complication must be considered.
Collapse
Affiliation(s)
| | - Michele Mercurio
- Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, "Mater Domini" University Hospital, Catanzaro, Italy
| | - Olimpio Galasso
- Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, "Mater Domini" University Hospital, Catanzaro, Italy.
| | - Valentina Sanzo
- Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, "Mater Domini" University Hospital, Catanzaro, Italy
| | - Marco De Gori
- Department of Orthopaedic and Trauma Surgery, Basso Ionio Hospital, Soverato, Italy
| | | | - Nicola Orlando
- Division of Orthopaedic and Trauma Surgery, "Villa Verde", Fermo, Italy
| | - Giorgio Gasparini
- Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, "Mater Domini" University Hospital, Catanzaro, Italy
| |
Collapse
|
4
|
Gauci MO, Glevarec L, Bronsard N, Cointat C, Pelletier Y, Boileau P, Gonzalez JF. Is preoperative 3D planning reliable for predicting postoperative clinical differences in range of motion between two stem designs in reverse shoulder arthroplasty. J Shoulder Elbow Surg 2024:S1058-2746(24)00051-X. [PMID: 38281677 DOI: 10.1016/j.jse.2023.11.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 11/20/2023] [Accepted: 11/27/2023] [Indexed: 01/30/2024]
Abstract
BACKGROUND We aim to predict a clinical difference in the postoperative range of motion (RoM) between 2 reverse shoulder arthroplasty (RSA) stem designs (Inlay-155° and Onlay-145°) using preoperative planning software. We hypothesized that preoperative 3D planning could anticipate the differences in postoperative clinical RoM between 2 humeral stem designs and by keeping the same glenoid implant. METHODS Thirty-seven patients (14 men and 23 women, 76 ± 7 years) underwent a BIO-RSA (bony increased offset-RSA) with the use of preoperative planning and an intraoperative 3-dimensional-printed patient-specific guide for glenoid component implantation between January 2014 and September 2019 with a minimum follow-up of 2 years. Two types of humeral implants were used: Inlay with a 155° inclination (Inlay-155°) and Onlay with a 145°inclination (Onlay-145°). Glenoid implants remained unchanged. The postoperative RSA angle (inclination of the area in which the glenoid component of the RSA is implanted) and the lateralization shoulder angle were measured to confirm the good positioning of the glenoid implant and the global lateralization on postoperative X-rays. A correlation between simulated and clinical RoM was studied. Simulated and last follow-up active forward flexion (AFE), abduction, and external rotation (ER) were compared between the 2 types of implants. RESULTS No significant difference in RSA and lateralization shoulder angle was found between planned and postoperative radiological implants' position. Clinical RoM at the last follow-up was always significantly different from simulated preoperative RoM. A low-to-moderate but significant correlation existed for AFE, abduction, and ER (r = 0.45, r = 0.47, and r = 0.57, respectively; P < .01). AFE and abduction were systematically underestimated (126° ± 16° and 95° ± 13° simulated vs. 150° ± 24° and 114° ± 13° postoperatively; P < .001), whereas ER was systematically overestimated (50° ± 19° simulated vs. 36° ± 19° postoperatively; P < .001). Simulated abduction and ER highlighted a significant difference between Inlay-155° and Onlay-145° (12° ± 2°, P = .01, and 23° ± 3°, P < .001), and this was also retrieved clinically at the last follow-up (23° ± 2°, P = .02, and 22° ± 2°, P < .001). CONCLUSIONS This study is the first to evaluate the clinical relevance of predicted RoM for RSA preoperative planning. Motion that involves the scapulothoracic joint (AFE and abduction) is underestimated, while ER is overestimated. However, preoperative planning provides clinically relevant RoM prediction with a significant correlation between both and brings reliable data when comparing 2 different types of humeral implants (Inlay-155° and Onlay-145°) for abduction and ER. Thus, RoM simulation is a valuable tool to optimize implant selection and choose RSA implants to reach the optimal RoM.
Collapse
Affiliation(s)
- Marc-Olivier Gauci
- Institut Universitaire Locomoteur et du Sport, CHU de Nice, Hôpital Pasteur II, Nice, France; ICARE laboratory, Inserm U1091, IBV, Université Côte d'Azur, Nice, France.
| | - Laure Glevarec
- Institut Universitaire Locomoteur et du Sport, CHU de Nice, Hôpital Pasteur II, Nice, France
| | - Nicolas Bronsard
- Institut Universitaire Locomoteur et du Sport, CHU de Nice, Hôpital Pasteur II, Nice, France; ICARE laboratory, Inserm U1091, IBV, Université Côte d'Azur, Nice, France
| | - Caroline Cointat
- Institut Universitaire Locomoteur et du Sport, CHU de Nice, Hôpital Pasteur II, Nice, France
| | - Yann Pelletier
- Institut Universitaire Locomoteur et du Sport, CHU de Nice, Hôpital Pasteur II, Nice, France
| | - Pascal Boileau
- Institut Universitaire Locomoteur et du Sport, CHU de Nice, Hôpital Pasteur II, Nice, France
| | - Jean-François Gonzalez
- Institut Universitaire Locomoteur et du Sport, CHU de Nice, Hôpital Pasteur II, Nice, France; ICARE laboratory, Inserm U1091, IBV, Université Côte d'Azur, Nice, France
| |
Collapse
|
5
|
Yamada E, Kozono N, Nabeshima A, Tashiro E, Nakashima Y. Baseplate inferior offset affects shoulder range of motion in reverse shoulder arthroplasty in Asian population. J Orthop Surg Res 2024; 19:25. [PMID: 38167444 PMCID: PMC10762829 DOI: 10.1186/s13018-023-04506-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Accepted: 12/22/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND Impingement is a common complication of reverse shoulder arthroplasty. Placement of the baseplate with a wide impingement-free angle is ideal; however, there are few studies on Asian populations, which have smaller height and physique, and there is a lack of guidance on achieving optimal outcomes. The purpose of the present study was to explore the impingement-free range of motion reverse shoulder arthroplasty and analyze the suitable baseplate position or tilt for the Asian population using simulation software. METHODS We uploaded computed tomography scan data from 20 Asian patients to three-dimensional (3D) simulation software. The implantation of the reverse shoulder arthroplasty component was performed on the 3D humerus and scapula using software, and range of motion was assessed until impingement occurred. RESULTS The range of motion in flexion significantly improved when the baseplate was lowered up to 3 mm inferiorly. Range of motion in abduction and internal and external rotation significantly improved as the baseplate was lowered up to 4 mm. There was no significant difference in range of motion in any motion after changing the inferior tilt, except in internal and external rotation. CONCLUSIONS The range of motion in abduction, flexion, and internal and external rotations significantly improved with increased inferior offset. These results may prove valuable in determining the optimal baseplate position for RSA, particularly in Asian populations.
Collapse
Affiliation(s)
- Erina Yamada
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan
| | - Naoya Kozono
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan.
| | - Akira Nabeshima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan
| | - Eiji Tashiro
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan
| |
Collapse
|
6
|
Harding GT, Bois AJ, Cavanagh JT, Bouliane MJ. The Use of an External Cutting Guide for Patient-Specific Bone Grafting in Reverse Total Shoulder Arthroplasty: A Novel Technique. J Shoulder Elb Arthroplast 2023; 7:24715492231219566. [PMID: 38106518 PMCID: PMC10722917 DOI: 10.1177/24715492231219566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 11/01/2023] [Accepted: 11/10/2023] [Indexed: 12/19/2023] Open
Abstract
Glenoid bone loss remains a substantial challenge in reverse shoulder arthroplasty and failure to address such bone loss may lead to implant malpositioning, instability and/or premature baseplate loosening. Currently, management of glenoid bone loss can be achieved by metal augmentation or bone grafting (ie, autograft or allograft). At the present time, options for creating and shaping glenoid bone grafts include free-hand techniques and simple reusable cutting guides that create the graft at a standard shape/angle. To our knowledge, there is no external guide available that enables surgeons to accurately prepare the bone graft to the desired dimensions/shape (ie, trapezoid or biplanar) to correct the glenoid deformity. In this article, we present a novel surgical technique that utilizes an external guide for creating a patient-specific bone graft to address glenoid deformity in the setting of reverse total shoulder arthroplasty.
Collapse
Affiliation(s)
- Graeme T Harding
- Department of Orthopaedic Surgery, University of Alberta, Edmonton, AB, Canada
| | - Aaron J Bois
- Section of Orthopaedic Surgery, Department of Surgery, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada
| | - Joseph T Cavanagh
- Department of Orthopaedic Surgery, University of Alberta, Edmonton, AB, Canada
| | - Martin J Bouliane
- Department of Orthopaedic Surgery, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
7
|
Franceschetti E, Giovannetti de Sanctis E, Gregori P, Paciotti M, Palumbo A, Franceschi F. Angled BIO-RSA leads to better inclination and clinical outcomes compared to Standard BIO-RSA and eccentric reaming: A comparative study. Shoulder Elbow 2023; 15:35-42. [PMID: 37974648 PMCID: PMC10649506 DOI: 10.1177/17585732211067156] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 11/20/2021] [Accepted: 11/10/2021] [Indexed: 11/19/2023]
Abstract
Background Two surgical techniques were compared : Standard BIO-RSA, performed with a glenoid eccentric reaming along with a cylindric bone graft augmentation vs. the Angled BIO-RSA, performed with a glenoid concentric reaming and a defect correction with an angled bone graft. Methods Patients undergoing RSA from January 2016 to April 2019, with one of the two techniques being performed, were retrospectively reviewed. Glenoids were classified according to Favard. Clinical (Constant-Murley, VAS and ROM) and radiographic (superior tilt correction) data were collected pre-operatively and at 12 months post-operatively. Results 141 shoulders were included. Angled BIO-RSA group showed statistically significant better outcomes in terms of forward flexion (149.9° Vs 139.3°) and abduction (136.4° Vs 126.7°). The use of an Angled BIO-RSA showed a statistically significant better superior tilt correction (1.252° Vs 4.09°). Angled BIO-RSA, leads to a better inclination correction and a mean postoperative tilt value inferior to 5° in E1 and E3 differently from standard BIO-RSA. Discussion Both techniques were able to correct glenoid superior inclination with excellent postoperative short-term results. However, angled BIO-RSA technique appears to be more effective in ensuring a correct inclination of the prosthetic glenoid component with better clinical outcomes.
Collapse
Affiliation(s)
- Edoardo Franceschetti
- Department of Orthopaedic and Trauma Surgery, Campus Biomedico University of Rome, Rome, Italy
| | | | - Pietro Gregori
- Department of Orthopaedic and Trauma Surgery, Campus Biomedico University of Rome, Rome, Italy
| | - Michele Paciotti
- Department of Orthopaedic and Trauma Surgery, Campus Biomedico University of Rome, Rome, Italy
| | - Alessio Palumbo
- Department of Orthopaedic and Trauma Surgery, San Pietro Fatebenefratelli Hospital, Rome, Italy
| | - Francesco Franceschi
- UniCamillus-Saint Camillus International University of Health Sciences, Rome, Italy
- Department of Orthopaedic and Trauma Surgery, San Pietro Fatebenefratelli Hospital, Rome, Italy
| |
Collapse
|
8
|
Zino Kuhn M, Hao KA, Cueto RJ, Dean EW, King JJ, Schoch BS, Wright JO, Farmer KW, Struk AM, Wright TW. Relationship between the prosthesis scapular neck angle and clinical outcomes in reverse shoulder arthroplasty. Shoulder Elbow 2023; 15:94-104. [PMID: 37974639 PMCID: PMC10649511 DOI: 10.1177/17585732231156428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 01/19/2023] [Accepted: 01/21/2023] [Indexed: 11/19/2023]
Abstract
Background Optimal glenosphere positioning in reverse shoulder arthroplasty (RSA) remains highly debated. We aimed to characterize the association between the prosthesis scapular neck angle (PSNA) and postoperative range of motion (ROM) and clinical outcome scores. Methods A retrospective review of 284 RSAs using a single design with minimum 2-year follow-up was performed. Glenosphere tilt was measured postoperatively using PSNA. ROM and functional outcome scores were assessed preoperatively and at latest follow-up. The PSNA was dichotomized to inferior or superior groups (>90° vs ≤ 90°, respectively) and stratified into quartiles; ROM and outcome score measures were compared between groups controlling for inferior glenosphere overhang. Results No range of PSNA was consistently associated with superior ROM, clinical outcome scores, or rates of complications including scapular notching. However, greater preoperative to postoperative improvement in active FE was found for superiorly (PSNA ≤ 90°) versus inferiorly tilted glenospheres (37° ± 33° vs 53° ± 35°, P = 0.005) and the greater improvement in active FE (57° ± 35°, P = 0.004) was further isolated to the first quartile (mean 85.1° ± 3.5°). Discussion A lack of variation in clinical outcomes based on PSNA suggests negligible short-term (median follow-up 3.1 years) clinical significance when glenosphere tilt falls within the distribution of this cohort (mean 92.6° ± 6.2°).
Collapse
Affiliation(s)
- M Zino Kuhn
- College of Medicine, University of Florida, Gainesville, FL, USA
| | - Kevin A Hao
- College of Medicine, University of Florida, Gainesville, FL, USA
| | - Robert J Cueto
- College of Medicine, University of Florida, Gainesville, FL, USA
| | - Ethan W Dean
- Piedmont Orthopedics | OrthoAtlanta, Atlanta, GA, USA
| | - Joseph J King
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Bradley S Schoch
- Department of Orthopedic Surgery, Mayo Clinic, Jacksonville, FL, USA
| | - Jonathan O Wright
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Kevin W Farmer
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Aimee M Struk
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Thomas W Wright
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| |
Collapse
|
9
|
Shekhbihi A, Mazzotta A, Reichert W, Masoud M. The base plate orientation angle: a plain radiographic technique for designing the base plate's inclination in reverse shoulder arthroplasty. JSES Int 2023; 7:2507-2516. [PMID: 37969506 PMCID: PMC10638608 DOI: 10.1016/j.jseint.2023.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2023] Open
Abstract
Background Superior inclination of the base plate in reverse shoulder arthroplasty (RSA) is underestimated and may lead to major setbacks in terms of functional outcomes due to the altered biomechanics. Joint instability, scapular notching, and loosening of the glenoid component are considered the most serious sequelae. Therefore, a thorough preoperative radiological assessment of the affected shoulder joint and customized design of the prosthesis according to the glenoid morphology are decisive and directly correlated to the outcome. In this article, we propose a simple radiographic technique to assess the inclination of the glenoid preoperatively, which identifies the need for intraoperative correction. Materials and Methods One hundred inconspicuous shoulder radiographs were included in the control group (CG) to define the normal ranges of the base plate orientation angle (BOA) and the base plate correction angle (BCA). Further, both angles were measured on 2-dimensional (2D) computed tomography scans of patients with proximal humerus fractures as well as radiographs, 2D and 3-dimensional (3D) computed tomography scans of patients with cuff tear arthropathy who underwent RSA between 2018 and 2021. The interobserver reliability among three independent testers was evaluated by calculating the intraclass correlation coefficient. In cuff tear arthropathy cases, the BOA and BCA measurements on different imaging modalities were compared using the Wilcoxon test. Possible variations of both angles' values based on glenoid erosion types, according to the Favard classification, were also investigated. Results Regardless of the imaging modality used, the interobserver reliability was excellent among three independent observers. In the CG, the mean BOA and BCA values were 118° ± 6° and 17° ± 5°, respectively. The mean corrected BOA values of the CG and fracture group were 136° ± 5° and 140° ± 5°, respectively. In contrast to the BCA values, the BOA measurements on radiographs showed a statistically significant difference compared to those obtained on 2D- and 3D scans in the cuff arthropathy group. Further, both angles' values varied according to the extent and location of the glenoid erosion. The lowest mean BOA and highest mean BCA values were observed in cases with Favard glenoid type E3. Conclusions The BOA and the BCA are reliable tools proposed to aid in precisely positioning the glenoid component in RSA in the preoperative setting. Whereas, the BOA determines the inclination of the inferior glenoid segment, the BCA represents the extent of correction required to obtain a neutral inclination of the base plate. Glenoid type E3 of the Favard classification with superior wear is particularly susceptible to base plate superior tilt.
Collapse
Affiliation(s)
- Abdelkader Shekhbihi
- Department of Trauma Surgery, Lörrach District Hospital, Baden-Württemberg, Germany
| | - Antonio Mazzotta
- Department of Trauma Surgery, Lörrach District Hospital, Baden-Württemberg, Germany
| | - Winfried Reichert
- Department of Trauma Surgery, Lörrach District Hospital, Baden-Württemberg, Germany
| | - Mohammad Masoud
- Department of Trauma Surgery, Lörrach District Hospital, Baden-Württemberg, Germany
- Department of Orthopaedics and Trauma Surgery, University Hospital of Assiut, Assiut, Egypt
| |
Collapse
|
10
|
Baek GR, Kim JG, Baek CH, Baek G, Chung MS, Kao O, McGarry MH, Lee TQ. Latissimus Dorsi and Teres major tendon transfer increases internal rotation torque following lateralized reverse shoulder arthroplasty with subscapularis insufficiency. Arch Orthop Trauma Surg 2023; 143:5759-5766. [PMID: 37069412 DOI: 10.1007/s00402-023-04861-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 03/22/2023] [Indexed: 04/19/2023]
Abstract
INTRODUCTION Limitation of active Internal Rotation (IR) following Reverse Shoulder Arthroplasty (RSA) in patients with massive Rotator Cuff Tears (mRCTs) with subscapularis insufficiency remains a challenge. Recently, RSA with Latissimus dorsi and Teres major (LDTM) transfer in patients with limited active IR has been demonstrated as a reliable treatment option. The purpose of this study was to biomechanically compare the IR torque following LDTM transfer with RSA in mRCT with subscapularis insufficiency to RSA without tendon transfer. METHODS Eight cadaveric shoulders were tested (mean age: 64.5 ± 1.9 years) using a custom shoulder testing system that permits loading conditions of mRCT with subscapularis insufficiency. Two conditions were tested and compared. The first condition was RSA alone and the second condition was RSA with LDTM transfer. RSA with a medialized glenoid and lateralized humerus design was used for all specimens. The specimens were tested at 0°, 20° and 40° abduction at three different muscle loads: baseline, double, and triple, while the Teres minor and deltoid loads were kept constant. IR torque was measured with a torque wrench at 0°, 20°, and 40° abduction and 60° and 45° IR positions. Force required for anterior dislocation was measured at 20° abduction and 10° IR position. RESULTS RSA with LDTM transfer had significantly higher IR torque at all abductions and muscle loading compared with RSA without transfer (average at all positions; RSA without transfer: 0.80 ± 0.02 Nm, LDTM transfer for all loads: 1.43 ± 0.10 Nm). RSA with LDTM transfer (91.4 ± 3.9 N) needed higher force for anterior dislocation compared to RSA alone (89.4 ± 4.1 N), but there was no significant difference. CONCLUSION LDTM transfer with RSA increases IR torque compared to RSA without tendon transfer in a cadaveric model. LDTM transfer with RSA may be a reliable treatment option for patients with mRCT and subscapularis insufficiency who are expected to have limited active IR following RSA.
Collapse
Affiliation(s)
- Gyu Rim Baek
- Orthopedic Biomechanics Laboratory, Congress Medical Foundation, 800 S Raymond Ave, Pasadena, CA, 91105, USA
| | - Jung Gon Kim
- Department of Orthopaedic Surgery, Yeosu Baek Hospital, Yeosu-si, Jeollanam-do, Republic of Korea
| | - Chang Hee Baek
- Department of Orthopaedic Surgery, Yeosu Baek Hospital, Yeosu-si, Jeollanam-do, Republic of Korea
| | - Gyuna Baek
- Orthopedic Biomechanics Laboratory, Congress Medical Foundation, 800 S Raymond Ave, Pasadena, CA, 91105, USA
| | - Min-Shik Chung
- Orthopedic Biomechanics Laboratory, Congress Medical Foundation, 800 S Raymond Ave, Pasadena, CA, 91105, USA
| | - Owen Kao
- Orthopedic Biomechanics Laboratory, Congress Medical Foundation, 800 S Raymond Ave, Pasadena, CA, 91105, USA
| | - Michelle H McGarry
- Orthopedic Biomechanics Laboratory, Congress Medical Foundation, 800 S Raymond Ave, Pasadena, CA, 91105, USA
| | - Thay Q Lee
- Orthopedic Biomechanics Laboratory, Congress Medical Foundation, 800 S Raymond Ave, Pasadena, CA, 91105, USA.
| |
Collapse
|
11
|
Jeong HJ, Kim SW, Rhee SM, Yeo JH, Heo K, Oh JH. Subacromial notching after reverse total shoulder arthroplasty. J Shoulder Elbow Surg 2023; 32:1876-1885. [PMID: 37024040 DOI: 10.1016/j.jse.2023.03.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 02/21/2023] [Accepted: 03/01/2023] [Indexed: 04/08/2023]
Abstract
BACKGROUND Scapular notching is a well-known postoperative complication of reverse total shoulder arthroplasty (RTSA). However, subacromial notching (SaN), a subacromial erosion caused by repeated abduction impingement after RTSA, has not been previously reported in a clinical setting. Therefore, this study aimed to assess the risk factors and functional outcomes of SaN after RTSA. METHODS We retrospectively reviewed the medical records of 125 patients who underwent RTSA with the same design between March 2014 and May 2017 and had at least 2 years of follow-up. SaN was defined as subacromial erosion observed at the final follow-up but not on the X-ray 3 months after surgery. Radiologic parameters representing the patient's native anatomy and degrees of lateralization and/or distalization during surgery were evaluated using preoperative and 3 months postoperative X-rays. The visual analogue scale of pain, active range of motion, and American Shoulder and Elbow Surgeons score were assessed preoperatively and at the final follow-up to evaluate the functional outcomes of SaN. RESULTS SaN occurred in 12.8% (16/125) of enrolled patients during the study period. Preoperative center of rotation-acromion distance (P = .009) and postoperative humerus lateralization offset, which evaluated the degree of lateralization after RTSA (P = .003), were risk factors for SaN. The preoperative center of rotation-acromion distance and postoperative humerus lateralization cutoff values were 14.0 mm and 19.0 mm, respectively. The visual analogue scale of pain (P = .01) and American Shoulder and Elbow Surgeons score (P = .04) at the final follow-up were significantly worse in patients with SaN. CONCLUSIONS SaN might adversely affect postoperative clinical outcomes. As SaN correlated with patients' anatomical characteristics and degree of lateralization during RTSA, the implant's degree of lateralization should be adjusted according to the patient's own anatomical characteristics.
Collapse
Affiliation(s)
- Hyeon Jang Jeong
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Sang Woo Kim
- Department of Orthopaedic Surgery, Nalgae Hospital, Seoul, Republic of Korea
| | - Sung-Min Rhee
- Department of Orthopaedic Surgery, Kyung Hee University College of Medicine, Kyung Hee University Medical Center, Seoul, Republic of Korea
| | - Ji Hyun Yeo
- Department of Orthopaedic Surgery, Hanam S Hospital, Hanam, Republic of Korea
| | - Kang Heo
- Department of Orthopaedic Surgery, Chambaro hospital, Seoul, Republic of Korea
| | - Joo Han Oh
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
| |
Collapse
|
12
|
Cuinet T, Nérot C, Godenèche A, Peduzzi L. Surgical Approach for RSA has Little or no Influence on Scapular Inclination and Glenoid Baseplate Tilt Relative to the Horizontal. J Shoulder Elb Arthroplast 2023; 7:24715492231192227. [PMID: 37575313 PMCID: PMC10422891 DOI: 10.1177/24715492231192227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 07/11/2023] [Accepted: 07/18/2023] [Indexed: 08/15/2023] Open
Abstract
Purpose Determine whether reverse shoulder arthroplasty (RSA) glenoid baseplate tilt is influenced by surgical approach and/or associated with functional scores. Methods In total, 501 shoulders (483 patients) who underwent RSA, by anterosuperior (AS, n = 88) or deltopectoral (DP, n = 413) approach. Preoperative and immediate postoperative anteroposterior and scapular Y-view radiographs were used to measure: Inclination of the supraspinatus fossa's floor relative to the horizontal (Sigma angle), inclination of the glenoid fossa line (or glenoid baseplate surface) relative to the horizontal (beta-h angle) or to the supraspinatus fossa's floor (beta-s angle). Results Sigma and beta-h were significantly greater for shoulders operated by DP approach, both preoperatively (P < .001, P = .002) and postoperatively (P = .004, P < .001), but net change was not significantly different (P = .501, P = .742). Conversely, beta-s was significantly greater for shoulders operated by DP approach, only postoperatively (P = .042), but there were no significant differences in either preoperative angles (P = .580) or net change thereof (P = .528). Conclusion Beta-s was slightly but significantly greater for shoulders operated by DP approach, while beta-h and sigma depended primarily on preoperative scapular inclination and glenoid tilt, rather than on surgical approach. At a minimum of 2 years following RSA, neither constant scores nor net improvements thereof were significantly associated with any of the angles. Level of evidence IV, case series.
Collapse
Affiliation(s)
- Thomas Cuinet
- Centre Chirurgical Émile-Gallé, CHU de Nancy, Nancy, France
- Université de Lorraine, Nancy, France
- SoFEC-French Shoulder and Elbow Society, Paris, France
| | - Cécile Nérot
- SoFEC-French Shoulder and Elbow Society, Paris, France
- Orthopaedic and Traumatology Department, Reims University Hospital, Reims, France
| | - Arnaud Godenèche
- SoFEC-French Shoulder and Elbow Society, Paris, France
- Hôpital Privé Jean Mermoz, Ramsay Santé, Centre Orthopédique Santy, Lyon, France
| | - Lisa Peduzzi
- Centre Chirurgical Émile-Gallé, CHU de Nancy, Nancy, France
- Université de Lorraine, Nancy, France
- SoFEC-French Shoulder and Elbow Society, Paris, France
| |
Collapse
|
13
|
Lee WS, Shin YB, Lee HD. Rotation of the eccentric glenosphere after reverse total shoulder arthroplasty: a case report. JSES REVIEWS, REPORTS, AND TECHNIQUES 2023; 3:376-381. [PMID: 37588501 PMCID: PMC10426588 DOI: 10.1016/j.xrrt.2023.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
Affiliation(s)
- Woo-Seung Lee
- Department of Orthopaedic Surgery, VHS (Veterans Health Service) Medical Center, Seoul, Republic of Korea
| | - Young-Bin Shin
- Department of Orthopaedic Surgery, VHS (Veterans Health Service) Medical Center, Seoul, Republic of Korea
| | - Hee Dong Lee
- Department of Orthopaedic Surgery, VHS (Veterans Health Service) Medical Center, Seoul, Republic of Korea
| |
Collapse
|
14
|
Boekel P, Rikard-Bell M, Grant A, Brandon B, Doma K, O’Callaghan WB, Wilkinson M, Morse L. Image-derived instrumentation vs. conventional instrumentation with 3D planning for glenoid component placement in reverse total shoulder replacements: a randomized controlled trial. JSES Int 2023; 7:614-622. [PMID: 37426909 PMCID: PMC10328789 DOI: 10.1016/j.jseint.2023.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/11/2023] Open
Abstract
Hypothesis Glenoid baseplate positioning for reverse total shoulder arthroplasty (rTSA) is important for stability and longevity, with techniques such as image-derived instrumentation (IDI) developed for improving implant placement accuracy. We performed a single-blinded randomized controlled trial comparing glenoid baseplate insertion accuracy with 3D preoperative planning and IDI jigs vs. 3D preoperative planning and conventional instrumentation. Methods All patients had a preoperative 3D computed tomography to create an IDI; then underwent rTSA according to their randomized method. Repeat computed tomography scans performed at six weeks postoperatively were compared to the preoperative plan to assess for accuracy of implantation. Patient-reported outcome measures and plain radiographs were collected with 2-year follow-up. Results Forty-seven rTSA patients were included (IDI n = 24, conventional instrumentation n = 23). The IDI group was more likely to have a guidewire placement within 2mm of the preoperative plan in the superior/inferior plane (P = .01); and exhibited a smaller degree of error when the native glenoid retroversion was >10° (P = .047). There was no difference in patient-reported outcome measures or other radiographic parameters between the two groups. Conclusion IDI is an accurate method for glenoid guidewire and component placement in rTSA, particularly in the superior/inferior plane and in glenoids with native retroversion >10°, when compared to conventional instrumentation.
Collapse
Affiliation(s)
- Pamela Boekel
- Orthopaedic Research Institute of Queensland, Pimlico, Queensland, Australia
- Department of Orthopaedic Surgery, Townsville University Hospital, James Cook University, Townsville, Queensland, Australia
| | - Matthew Rikard-Bell
- Orthopaedic Research Institute of Queensland, Pimlico, Queensland, Australia
- Department of Orthopaedic Surgery, Townsville University Hospital, James Cook University, Townsville, Queensland, Australia
| | - Andrea Grant
- Orthopaedic Research Institute of Queensland, Pimlico, Queensland, Australia
| | - Benjamin Brandon
- Orthopaedic Research Institute of Queensland, Pimlico, Queensland, Australia
- Department of Orthopaedic Surgery, Townsville University Hospital, James Cook University, Townsville, Queensland, Australia
| | - Kenji Doma
- Orthopaedic Research Institute of Queensland, Pimlico, Queensland, Australia
- Department of Sports and Exercise Science, James Cook University, Townsville, Queensland, Australia
| | - William B. O’Callaghan
- Orthopaedic Research Institute of Queensland, Pimlico, Queensland, Australia
- Department of Orthopaedic Surgery, Cairns Hospital, Cairns, Queensland, Australia
| | - Matthew Wilkinson
- Orthopaedic Research Institute of Queensland, Pimlico, Queensland, Australia
- Department of Orthopaedic Surgery, Royal Hobart Hospital and Calvary Care, University of Tasmania, Hobart, Tasmania, Australia
| | - Levi Morse
- Orthopaedic Research Institute of Queensland, Pimlico, Queensland, Australia
- Department of Orthopaedic Surgery, Townsville University Hospital, James Cook University, Townsville, Queensland, Australia
| |
Collapse
|
15
|
Jennewine BR, Brolin TJ. Emerging Technologies in Shoulder Arthroplasty: Navigation, Mixed Reality, and Preoperative Planning. Orthop Clin North Am 2023; 54:209-225. [PMID: 36894293 DOI: 10.1016/j.ocl.2022.11.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
Shoulder arthroplasty is a rapidly improving and utilized management for end-stage arthritis that is associated with improved functional outcomes, pain relief, and long-term implant survival. Accurate placement of the glenoid and humeral components is critical for improved outcomes. Traditionally, preoperative planning was limited to radiographs and 2-dimensional computed tomography (CT); however, 3-dimensional CT is becoming more commonly utilized and necessary to understand complex glenoid and humeral deformities. To further increase accurate component placement, intraoperative assistive devices-patient-specific instrumentation, navigation, and mixed reality-minimize malpositioning, increase surgeon accuracy, and maximize fixation. These intraoperative technologies likely represent the future of shoulder arthroplasty.
Collapse
Affiliation(s)
- Brenton R Jennewine
- Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center-Campbell Clinic, 920 Madison Avenue, Memphis, TN 38163, USA; Campbell Clinic Orthopaedics, 1211 Union Avenue #500, Memphis, TN 38104, USA
| | - Tyler J Brolin
- Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center-Campbell Clinic, 920 Madison Avenue, Memphis, TN 38163, USA; Campbell Clinic Orthopaedics, 1400 South Germantown Road, Germantown, TN 38138, USA.
| |
Collapse
|
16
|
Reina M, Fiumana G, Mantovani M, D'Antonio L, Porcellini G. Scapulohumeral rhythm in shoulders with reverse shoulder arthroplasty measured with a new portable three-dimensional scapular kinematics assessment system. J Shoulder Elbow Surg 2023; 32:729-737. [PMID: 36621748 DOI: 10.1016/j.jse.2022.12.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 11/19/2022] [Accepted: 12/09/2022] [Indexed: 01/07/2023]
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) is a valid and increasingly popular treatment option in eccentric arthrosis and cuff arthropathy. We know that the deltoid is the motor of RSA. However, the role of scapular motion has been poorly documented in the literature. The aim of our study is to analyze and quantify the role of the scapular contribution in the functional outcome of patients undergoing RSA. MATERIALS AND METHODS Fourteen patients who underwent primary RSA were included in the study. In all cases, a reverse prosthesis with lateralizing stem was implanted. All patients underwent clinical examination, video recording, and motion analysis. X-ray and postoperative CT examinations were collected to evaluate positioning and any loosening. ShowMotion (NCS Lab srl, Modena, Italy) 3D kinematic tracking system was used to evaluate and measure the scapular motion in 3 planes. RESULTS All patients show substantial amount of posterior tilting and lateral rotation starting at 30° in forward elevation. A further difference is the anticipation of the retraction during the range of motion in the RSA side. The contribution of scapular motion in the RSA shoulder was greater than in the healthy shoulder. In patients with bilateral RSA, the contribution of scapular motion was higher in tilting and lateral rotation in the worse shoulder side in terms of range of motion. This means that to compensate for the loss of glenohumeral motion in RSA, more scapula-thoracic motion is needed to obtain the same thoraco-humeral elevation angle. CONCLUSIONS In the light of what has been measured, the post-RSA scapular kinematics has typical characteristics that must be achieved in order to obtain a good functional outcome. We can conclude that on the RSA side, the patients anticipate upward rotation both in flexion and abduction. The contribution of the upward rotation to elevation in the RSA group is therefore more significant. In addition to this, to facilitate elevation movements, there is an anticipation of the scapular retraction and a more prominent tilt resulting in different scapular kinematics. The analysis of scapular motion could be useful in the postoperative follow-up of patients undergoing RSA surgery and improve adaptative physiotherapy protocols. It potentially can even be included in future arthroplasty planning systems.
Collapse
Affiliation(s)
- Micaela Reina
- Department of Orthopedics and Traumatology, IRCC A. Gemelli University Polyclinic Foundation, Rome, Italy
| | | | | | - Lucio D'Antonio
- Department of Sport Medicine, University of Modena and Reggio Emilia, Modena, Italy
| | - Giuseppe Porcellini
- Department of Orthopedic and Traumatology, University of Modena and Reggio Emilia, Modena, Italy.
| |
Collapse
|
17
|
Bravman JT. In Primary RSA, Deltopectoral and Anterosuperior Approaches Differed for Glenosphere Tilt and Beta Angles but Not for Glenosphere Overhang or Prosthesis-Scapular Neck Angle. J Bone Joint Surg Am 2023; 105:806. [PMID: 36943928 DOI: 10.2106/jbjs.23.00148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Affiliation(s)
- Jonathan T Bravman
- CU Sports Medicine and Performance Center, University of Colorado, Boulder, Colorado
| |
Collapse
|
18
|
Computer-assisted analysis of functional internal rotation after reverse total shoulder arthroplasty: implications for component choice and orientation. J Exp Orthop 2023; 10:23. [PMID: 36917396 PMCID: PMC10014642 DOI: 10.1186/s40634-023-00580-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 01/25/2023] [Indexed: 03/16/2023] Open
Abstract
PURPOSE Functional internal rotation (IR) is a combination of extension and IR. It is clinically often limited after reverse total shoulder arthroplasty (RTSA) either due to loss of extension or IR in extension. It was the purpose of this study to determine the ideal in-vitro combination of glenoid and humeral components to achieve impingement-free functional IR. METHODS RTSA components were virtually implanted into a normal scapula (previously established with a statistical shape model) and into a corresponding humerus using a computer planning program (CASPA). Baseline glenoid configuration consisted of a 28 mm baseplate placed flush with the posteroinferior glenoid rim, a baseplate inclination angle of 96° (relative to the supraspinatus fossa) and a 36 mm standard glenosphere. Baseline humeral configuration consisted of a 12 mm humeral stem, a metaphysis with a neck shaft angle (NSA) of 155° (+ 6 mm medial offset), anatomic torsion of -20° and a symmetric PE inlay (36mmx0mm). Additional configurations with different humeral torsion (-20°, + 10°), NSA (135°, 145°, 155°), baseplate position, diameter, lateralization and inclination were tested. Glenohumeral extension of 5, 10, 20, and 40° was performed first, followed by IR of 20, 40, and 60° with the arm in extension of 40°-the value previously identified as necessary for satisfactory clinical functional IR. The different component combinations were taken through simulated ROM and the impingement volume (mm3) was recorded. Furthermore, the occurrence of impingement was read out in 5° motion increments. RESULTS In all cases where impingement occurred, it occurred between the PE inlay and the posterior glenoid rim. Only in 11 of 36 combinations full functional IR was possible without impingement. Anterosuperior baseplate positioning showed the highest impingement volume with every combination of NSA and torsion. A posteroinferiorly positioned 26 mm baseplate resulting in an additional 2 mm of inferior overhang as well as 6 mm baseplate lateralization offered the best impingement-free functional IR (5/6 combinations without impingement). Low impingement potential resulted from a combination of NSA 135° and + 10° torsion (4/6 combinations without impingement), followed by NSA 135° and -20° torsion (3/6 combinations without impingement) regardless of glenoid setup. CONCLUSION The largest impingement-free functional IRs resulted from combining a posteroinferior baseplate position, a greater inferior glenosphere overhang, 90° of baseplate inclination angle, 6 mm glenosphere lateralization with respect to baseline setup, a lower NSA and antetorsion of the humeral component. Surgeons can employ and combine these implant configurations to achieve and improve functional IR when planning and performing RTSA. LEVEL OF EVIDENCE Basic Science Study, Biomechanics.
Collapse
|
19
|
Challenges for Optimization of Reverse Shoulder Arthroplasty Part I: External Rotation, Extension and Internal Rotation. J Clin Med 2023; 12:jcm12051814. [PMID: 36902601 PMCID: PMC10003696 DOI: 10.3390/jcm12051814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/06/2023] [Accepted: 02/16/2023] [Indexed: 03/06/2023] Open
Abstract
A detailed overview of the basic science and clinical literature reporting on the challenges for the optimization of reverse shoulder arthroplasty (RSA) is presented in two review articles. Part I looks at (I) external rotation and extension, (II) internal rotation and the analysis and discussion of the interplay of different factors influencing these challenges. In part II, we focus on (III) the conservation of sufficient subacromial and coracohumeral space, (IV) scapular posture and (V) moment arms and muscle tensioning. There is a need to define the criteria and algorithms for planning and execution of optimized, balanced RSA to improve the range of motion, function and longevity whilst minimizing complications. For an optimized RSA with the highest function, it is important not to overlook any of these challenges. This summary may be used as an aide memoire for RSA planning.
Collapse
|
20
|
Bauer S, Blakeney WG, Wang AW, Ernstbrunner L, Corbaz J, Werthel JD. Challenges for Optimization of Reverse Shoulder Arthroplasty Part II: Subacromial Space, Scapular Posture, Moment Arms and Muscle Tensioning. J Clin Med 2023; 12:1616. [PMID: 36836151 PMCID: PMC9958610 DOI: 10.3390/jcm12041616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 02/11/2023] [Accepted: 02/13/2023] [Indexed: 02/22/2023] Open
Abstract
In part II of this comprehensive review on the optimization of reverse shoulder arthroplasty (RSA), we focus on three other challenges: 1. "Conservation of sufficient subacromial and coracohumeral space"; 2. "Scapular posture"; and 3. "Moment arms and muscle tensioning". This paper follows a detailed review of the basic science and clinical literature of the challenges in part I: 1. "External rotation and extension" and 2. "Internal rotation". "Conservation of sufficient subacromial and coracohumeral space" and "Scapular posture" may have a significant impact on the passive and active function of RSA. Understanding the implications of "Moment arms and muscle tensioning" is essential to optimize active force generation and RSA performance. An awareness and understanding of the challenges of the optimization of RSA help surgeons prevent complications and improve RSA function and raise further research questions for ongoing study.
Collapse
Affiliation(s)
- Stefan Bauer
- Service d’Orthopédie et de Traumatologie, Chirurgie de l’Épaule, Ensemble Hospitalier de la Côte, 1110 Morges, Switzerland
- Medical School, University of Western Australia, 35 Sterling Highway, Perth, WA 6009, Australia
| | - William G. Blakeney
- Medical School, University of Western Australia, 35 Sterling Highway, Perth, WA 6009, Australia
- Department of Orthopaedic Surgery, Royal Perth Hospital, Perth, WA 6000, Australia
| | - Allan W. Wang
- Medical School, University of Western Australia, 35 Sterling Highway, Perth, WA 6009, Australia
| | - Lukas Ernstbrunner
- Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, VIC 3050, Australia
- Department of Biomedical Engineering, University of Melbourne, Parkville, Melbourne, VIC 3010, Australia
| | - Jocelyn Corbaz
- Service d’Orthopédie et de Traumatologie, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland
| | - Jean-David Werthel
- Service d’Orthopédie et de Traumatologie, Hôpital Ambroise Paré, 9 Avenue Charles de Gaulle, 92100 Boulogne-Billancourt, France
| |
Collapse
|
21
|
Werthel JD, Villard A, Kazum E, Deransart P, Ramirez O. Accuracy of reverse shoulder arthroplasty angle according to the size of the baseplate. J Shoulder Elbow Surg 2023; 32:310-317. [PMID: 35998779 DOI: 10.1016/j.jse.2022.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 06/28/2022] [Accepted: 07/07/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Glenoid inclination must be assessed precisely during preoperative planning for reverse shoulder arthroplasty (RSA) to position the glenoid baseplate correctly. We hypothesized that a more dynamic measurement method would better match the diversity of glenoid heights in the population and the variety of commercialized glenoid baseplates. Our purpose was to describe a new method to measure the RSA angle accounting for the baseplate size. METHODS Computed tomography scans of 50 shoulders that underwent RSA for primary osteoarthritis or cuff tear arthropathy between June 2019 and February 2020 were included (mean age, 76 years). Three variants of the RSA angle were measured: the RSA angle as originally described by Boileau et al, the relative RSA 25 angle (which simulates the implantation of a 25-mm baseplate), and the relative RSA 29 angle (which simulates the implantation of a 29-mm baseplate). Measurements in the 2-dimensional true reformatted scapular plane were made by 3 independent operators. RESULTS The mean R-S distance (ie, distance between point R [intersection of supraspinatus fossa line with glenoid surface] and point S [inferior border of glenoid]) was 24.2 ± 4.0 mm. The mean RSA angle was 20.3° ± 8.4°, whereas the mean relative RSA 25 angle was 19.3° ± 7.8° and the mean relative RSA 29 angle was 15.6° ± 7.6°. The mean difference between the RSA angle and the relative RSA 25 angle was 1.0° ± 4.1° (P = .16). The mean difference between the RSA angle and the relative RSA 29 angle was 4.7° ± 3.8° (P < .0001). In half of the shoulders in our series, the difference between the RSA angle and the RSA 29 angle exceeded 5°. CONCLUSION The RSA angle is a reproducible measure of the inclination of the inferior part of the glenoid that is reliable in most cases for glenoid baseplates of 24-25 mm in height. However, surgeons should be aware that the RSA angle may overestimate the superior orientation of the inferior glenoid for baseplates of different sizes or for small- or large-stature patients. In these cases, the relative RSA angle adapted to the size of the baseplate more accurately evaluates the inclination of the inferior glenoid.
Collapse
Affiliation(s)
| | | | - Efi Kazum
- Division of Orthopaedic Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | | | | |
Collapse
|
22
|
Velasquez Garcia A, Abdo G. Does computer-assisted navigation improve baseplate screw configuration in reverse shoulder arthroplasty? A systematic review and meta-analysis of comparative studies. J Orthop 2023; 36:29-35. [PMID: 36582549 PMCID: PMC9793209 DOI: 10.1016/j.jor.2022.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 10/18/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
Introduction Navigation technologies have improved accuracy and precision in positioning glenoid components during shoulder arthroplasty. The influence of navigation on baseplate screw placement has not been independently investigated. This study aimed to evaluate and synthesize the best scientific evidence on the influence of intraoperative navigation on the length and number of screws for primary baseplate fixation in reverse total shoulder arthroplasty procedures. Methods In August 2022, PubMed, Scopus, and Embase databases were accessed. We analyzed the screw purchase length, the number of screws required for the fixation of the baseplate, and the proportion of cases fixed with two screws in all clinical trials, comparing navigation to standard instrumentation for reverse shoulder arthroplasty. Following an evaluation of the heterogeneity of the studies, DerSimonian-Laird random-effects models were utilized to merge data from separate studies. Results The systematic search revealed a total of 2034 articles. After excluding duplicates and irrelevant studies, 633 shoulder arthroplasties from 6 trials were included in the analysis. The pooled mean difference in screw purchase length was 5.839 mm (95 %CI 4.496 to 7. 182) in favor of navigation (P < .001). In addition, significant differences were also found in the number of screws per case (- 0.547, 95 %CI -0.890 to -0.203, P = .002) and in the proportion of cases fixed with two screws (Odds Ratio 3.182 95 %CI 1.057 to 9.579, P = .040) in favor of the navigation group. Conclusions Intraoperative navigation improves the baseplate screw placement, allowing for a greater screw purchase length and fewer screws to achieve primary fixation of the glenoid component during reverse shoulder arthroplasty. It is unclear whether these improvements will increase the longevity of the prosthesis or the clinical outcomes of the patients.
Collapse
Affiliation(s)
- Ausberto Velasquez Garcia
- Department of Orthopedic Surgery, Clinica Universidad de Los Andes, Santiago, Chile
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Glen Abdo
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
- St Mary's General Hospital, Department of Graduate Medical Education, Internal Medicine Residence Program, Passaic, NJ, USA
- Department of Basic Sciences, Touro College of Osteopathic Medicine, New York, NY, USA
| |
Collapse
|
23
|
Machado GLR, Castro RQ, Forechi L, Souza HDC, Fonseca DS, Garcia MAC. The impact of Chikungunya chronic arthralgia on women’s upper limbs motor function: a cross-sectional study. FISIOTERAPIA E PESQUISA 2022. [DOI: 10.1590/1809-2950/22011229042022en] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2023] Open
Abstract
ABSTRACT Post-Chikungunya chronic arthralgia (PCCA) may lead to musculoskeletal repercussions and functional loss. The objective was to assess the upper limb physical disability and symptoms during daily, work, and leisure activities of women presenting PCCA compared to healthy controls (HC). This was a cross-sectional study conducted with 52 women. The participants were divided into PCCA (37) and HC (15) groups. Handgrip strength, range of motion, level of pain (numerical rating scale), and participants’ physical disability and symptoms (Disabilities of the Arm, Shoulder, and Hand Questionnaire - DASH) were evaluated. Differences between groups were evaluated using the Students t-test and Pearson’s correlations. The chi-square test was applied for categorical variables. The significance was set at α=0.05. The disease duration was 19.5±13.1 months. We found no differences between groups for peak force (PCAA:23.6±7.4kgf; HC: 24.5±6.2kgf; p=0.676). The results showed a significant difference between groups regarding range of motion (PCCA: 63.5±17.3o; HC: 77.2±9.6o), level of hand pain (PCCA: 5.8±2.2; HC: 0.4±1.5), and upper limbs functional levels (PCCA: 44.5±17.4; HC: 16.2±20.5). Participants related severe difficulty or inability to perform tasks such as opening a jar (78.4%), placing objects above head height (48.7%), doing heavy household chores (56.8%), and gardening (51.4%). Impairment in the upper limb physical function in daily, work, and leisure activities shows the higher prevalence in the long-term.
Collapse
|
24
|
Dean EW, Dean NE, Wright TW, Hao KA, Schoch BS, Farmer KW, Struk AM, King JJ. Clinical outcomes related to glenosphere overhang in reverse shoulder arthroplasty using a lateralized humeral design. J Shoulder Elbow Surg 2022; 31:2106-2115. [PMID: 35472577 DOI: 10.1016/j.jse.2022.03.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 03/06/2022] [Accepted: 03/14/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Previous studies have demonstrated that decreased impingement-free range of motion (ROM) can adversely influence clinical outcomes following reverse shoulder arthroplasty (RSA). Inferior placement of the glenosphere is thought to minimize impingement and its associated sequelae. This study evaluated the relationship between inferior overhang of the glenosphere and clinical outcomes in patients undergoing primary RSA using a lateralized humeral implant design. METHODS By use of a prospectively collected shoulder arthroplasty database, all primary RSAs performed at our institution between 2007 and 2015 with a single implant design (lateralized humerus and medialized glenoid) and minimum 2-year follow-up were evaluated. Glenosphere overhang in relation to the inferior rim of the glenoid was measured in millimeters on postoperative Grashey radiographs of the shoulder and categorized into tertiles (low, <7.1 mm; medium, 7.1 to 9.9 mm; and high, >9.9 mm). Clinical outcomes of interest comprised the changes between preoperative and postoperative values in the following ROM and outcome score measures: active forward elevation (aFE), active external rotation, American Shoulder and Elbow Surgeons score, Constant-Murley score, Shoulder Pain and Disability Index score, and Simple Shoulder Test score. Random-effects linear models were used to assess univariate and multivariable associations between overhang tertile and change in patient outcomes. Differences in outcomes were further compared using the minimal clinically important difference (MCID). RESULTS The study identified 284 shoulders in 265 patients. The median follow-up period was 36 months (range, 24-108 months). The median glenosphere inferior overhang was 8.4 mm, with an interquartile range of 6.3-10.6 mm. Plots demonstrated nonlinear relationships between overhang and outcome scores and between overhang and ROM. Patients with high overhang experienced a significantly greater improvement in aFE compared with patients with low overhang (P = .019), which exceeded the MCID. No other differences in ROM and outcome scores between overhang groups exceeded the MCID. For other outcome scores and ROM measurements, there was no significant relationship with glenosphere overhang. Increased overhang was associated with a significantly lower incidence of scapular notching (P = .005). CONCLUSION Patients undergoing RSA using a lateralized humerus design with greater inferior overhang of the glenosphere demonstrated a significantly greater improvement in aFE and lower rate of notching compared with those with low overhang. No ideal glenosphere overhang range was identified to maximize function in this study.
Collapse
Affiliation(s)
- Ethan W Dean
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Natalie E Dean
- Department of Biostatistics, University of Florida, Gainesville, FL, USA
| | - Thomas W Wright
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Kevin A Hao
- College of Medicine, University of Florida, Gainesville, FL, USA
| | - Bradley S Schoch
- Department of Orthopedic Surgery, Mayo Clinic, Jacksonville, FL, USA
| | - Kevin W Farmer
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Aimee M Struk
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Joseph J King
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA.
| |
Collapse
|
25
|
Jerosch J. [Cuff Arthropathy - Inverse Total Shoulder Arthroplasty (iSTEP) - Biomechanical Principles, Complications and Outcomes]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2022; 160:573-591. [PMID: 36167084 DOI: 10.1055/a-1388-2535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
The inverse total shoulder prosthesis is a standard treatment for cuff arthropathy. The number of implanted inverse total shoulder prostheses in Germany is significantly higher than that of the anatomical total shoulder prosthesis. Kaplan-Meier analyses show a 10-year result of inverse total shoulder prostheses after cuff arthropathy of 90%. The extent of the scapular notching correlates with the functional clinical outcome. The humeral anchoring principles of inverse total shoulder prosthesis differ considerably (from purely epiphyseal to diaphyseal). Inverse total shoulder prostheses show significant differences in humeral and glenoid offset as well as in shaft-neck angles. The large number of systems available differ considerably concerning anatomical and biomechanical parameters - the surgeons must be trained accordingly. Still, most shoulder replacements are implanted by surgeons who rarely perform this procedure.
Collapse
|
26
|
Castagna A, Borroni M, Dubini L, Gumina S, Delle Rose G, Ranieri R. Inverted-Bearing Reverse Shoulder Arthroplasty: Consequences on Scapular Notching and Clinical Results at Mid-Term Follow-Up. J Clin Med 2022; 11:jcm11195796. [PMID: 36233664 PMCID: PMC9572577 DOI: 10.3390/jcm11195796] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 09/09/2022] [Accepted: 09/25/2022] [Indexed: 11/16/2022] Open
Abstract
Background: Scapular notching following reverse shoulder arthroplasty (RSA) is caused by both biological and mechanical mechanisms. Some authors postulated that osteolysis that extends over the inferior screw is caused mainly by biological notching. Inverted-bearing RSA (IB-RSA) is characterized by a polyethylene glenosphere and a metallic humeral liner, decreasing the poly debris formation and potentially reducing high grades of notching. This study aims to report the results of IB-RSA on a consecutive series of patients at mid-term follow-up, focusing on the incidence of Sirveaux grade 3 and 4 scapular notching. Methods: A retrospective study on 78 consecutive patients who underwent primary IB-RSA between 2015−2017 was performed. At a 4 years minimum follow-up, 49 patients were evaluated clinically with Constant score (CS), Subjective shoulder value (SSV), American Shoulder and Elbow score (ASES), pain and range of motion, and with an X-ray assessing baseplate position (high, low), implant loosening, and scapular notching. Results: At a mean follow-up of 5.0 ± 0.9, all the clinical parameters improved (p < 0.05). One patient was revised for an infection and was excluded from the evaluation, two patients had an acromial fracture, and one had an axillary neuropraxia. Scapular notching was present in 13 (27%) patients (six grade 1, seven grade 2) and no cases of grade 3 and 4 were observed. Scapular nothing was significantly associated with high glenoid position (p < 0.001) and with lower CS (70 ± 15 vs. 58 ± 20; p = 0.046), SSV (81 ± 14 vs. 68 ± 20; p = 0.027), ASES (86 ± 14 vs. 70 ± 22; p = 0.031), and anterior elevation (148 ± 23 vs. 115 ± 37; p = 0.006). A 44 mm- compared to 40 mm-glenosphere was associate with better CS (63 ± 17 vs. 78 ± 11; p = 0.006), external (23 ± 17 vs. 36 ± 17; p = 0.036), and internal rotation (4.8 ± 2.7 vs. 7.8 ± 2.2; p = 0.011). Conclusions: IB-RSA is a safe and effective procedure for mid-term follow-up. Inverting biomaterials leads to a distinct kind of notching with mainly mechanical features. Scapular notching is associated with a high baseplate position and has a negative influence on range of motion and clinical outcome.
Collapse
Affiliation(s)
- Alessandro Castagna
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Rozzano (Mi), 20090 Milan, Italy
- IRCCS Humanitas Clinical and Research Center, Via Manzoni 56, Rozzano (Mi), 20089 Milan, Italy
| | - Mario Borroni
- IRCCS Humanitas Clinical and Research Center, Via Manzoni 56, Rozzano (Mi), 20089 Milan, Italy
| | - Luigi Dubini
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Rozzano (Mi), 20090 Milan, Italy
| | - Stefano Gumina
- Department of Anatomy, Histology, Forensic Medicine and Orthopaedics, Sapienza University of Rome, Piazzale Aldo Moro 5, 00185 Roma, Italy
- Istituto Clinico Ortopedico Traumatologico (ICOT), Via Franco Faggiana 1668, 04100 Latina, Italy
| | - Giacomo Delle Rose
- IRCCS Humanitas Clinical and Research Center, Via Manzoni 56, Rozzano (Mi), 20089 Milan, Italy
| | - Riccardo Ranieri
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Rozzano (Mi), 20090 Milan, Italy
- Correspondence: ; Tel.: +39-33-8857-1926
| |
Collapse
|
27
|
Glenday J, Sivarasu S, Roche S, Kontaxis A. Development of a framework to assess the biomechanical impact of reverse shoulder arthroplasty placement modifications. J Orthop Res 2022; 40:2156-2168. [PMID: 34878675 DOI: 10.1002/jor.25238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 11/11/2021] [Accepted: 12/04/2021] [Indexed: 02/04/2023]
Abstract
Reverse shoulder arthroplasty biomechanics can be improved by modifying the placement of prosthesis. Biomechanical studies have quantified the impact of placement modifications on the mobility and stability of the reverse shoulder. While these studies have provided detailed insights, direct comparisons between their finding are obfuscated by their use of differing methodologies. The aim of our study was to develop an assessment framework which used musculoskeletal simulations to consistently evaluate the biomechanics of various placement modifications. We conducted musculoskeletal simulations of humeral elevations and rotations using 15 reverse shoulder models. For each model, these simulations were conducted for a reference configuration of the prosthesis, established using surgical guidelines, and 34 modified configurations, which were based on commonplace adaptations to the placement of the glenosphere and humeral tray. The effect of each modified configuration on deltoid elongation, deltoid moment arm (DMA), joint stability, and impingement-free range of motion (IFROM) was determined relative to the reference configuration. We found that 16 of the 34 modified placements had an overall beneficial impact on reverse shoulder biomechanics. Within this subset, we identified two biomechanical trade-offs. First, there is an antagonistic relationship between IFROM and both the DMA and joint stability. Second, functional requirements differ between humeral elevations and rotations. Furthermore, we found that posteromedial translation of the humeral tray had the most beneficial impact on joint stability and inferior translation of the glenosphere had the most beneficial impact on IFROM and DMA.
Collapse
Affiliation(s)
- Jonathan Glenday
- Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa.,Department of Biomechanics, Hospital for Special Surgery, New York, NY, USA
| | - Sudesh Sivarasu
- Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
| | - Stephen Roche
- Department of Orthopaedic Surgery, Groote Schuur Hospital, Cape Town, South Africa
| | - Andreas Kontaxis
- Leon Root Motion Analysis Laboratory, Rehabilitation Department, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
28
|
Central fixation element type and length affect glenoid baseplate micromotion in reverse shoulder arthroplasty. J Shoulder Elbow Surg 2022; 31:1385-1392. [PMID: 35172207 DOI: 10.1016/j.jse.2022.01.120] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 01/03/2022] [Accepted: 01/09/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) is commonly used to treat patients with rotator cuff tear arthropathy. Loosening of the glenoid component remains one of the principal modes of failure and represents a significant complication that requires revision surgery. This study assessed the effects of various factors on glenoid baseplate micromotion for primary fixation of RSA. MATERIALS AND METHODS A half-fractional factorial design of experiment was used to assess 4 factors: central element type (central peg or screw), central cortical engagement according to length (13.5 or 23.5 mm), anterior-posterior peripheral screw type (nonlocking or locking), and cancellous bone surrogate density (160 or 400 kg/m3, 10 or 25 PCF). Glenoid baseplates were implanted into high- or low-density Sawbones rigid polyurethane foam blocks and cyclically loaded at 60° for 1000 cycles (500-N compressive force range) using a custom-designed loading apparatus. Micromotion at the 4 peripheral screw positions was recorded using linear variable differential transformers. RESULTS Central peg fixation generated 358% greater micromotion at all peripheral screw positions compared with central screw fixation (P < .001). Baseplates with short central elements that lacked cortical bone engagement generated 328% greater micromotion than those with long central elements (P = .001). No significant effects were observed when varying anterior-posterior peripheral screw type or bone surrogate density. There were significant interactions between central element type and length (P < .001). DISCUSSION A central screw and a long central element that engaged cortical bone reduced RSA baseplate micromotion. These findings serve to inform surgical decision making regarding baseplate fixation elements to minimize the risk of glenoid loosening and, thus, the need for revision surgery.
Collapse
|
29
|
Rohman E, King JJ, Roche CP, Fan W, Kilian CM, Papandrea RF. Factors associated with improvement or loss of internal rotation after reverse shoulder arthroplasty. J Shoulder Elbow Surg 2022; 31:e346-e358. [PMID: 35167915 DOI: 10.1016/j.jse.2022.01.124] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 01/03/2022] [Accepted: 01/09/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Internal rotation (IR) with reverse total shoulder arthroplasty (rTSA) can be unpredictable. Identifying the factors associated with loss of or improved IR could aid preoperative patient counseling. This study quantifies the change in IR experienced by rTSA patients with nonfracture indications and identifies the patient, implant, and operative factors associated with IR loss or gain at 2-year minimum follow-up. METHODS A total of 1978 primary rTSA patients were analyzed from an international database of a single rTSA prosthesis to quantify IR at 2 years' minimum follow-up. rTSA patients were divided into 2 cohorts based on their preoperative IR score, with group 1 patients having less active IR as defined by a preoperative IR score ≤3 and group 2 patients having greater active IR as defined by a preoperative IR score ≥4 (ie, L5 or higher). For both group 1 and 2 patients, univariate and multivariate analyses were performed to quantify the risk factors associated with IR loss after rTSA. RESULTS Overall, 58.9% of rTSA patients experienced IR improvement and 17.0% lost IR after rTSA. The occurrence of IR loss or gain was dependent on preoperative IR score, as 73.2% of group 1 patients improved IR and only 40.1% of group 2 patients improved IR, whereas 31.0% of group 2 patients lost IR and only 6.3% of group 1 patients lost IR after rTSA. Numerous risk factors for IR loss were identified. For group 1 patients, male sex (P = .004, odds ratio [OR] = 2.056), tobacco usage (P = .004, OR = 0.348), larger humeral stem diameter (P = .008, OR = 0.852), and not having subscapularis repaired (P = .002, OR = 2.654) were significant risk factors for IR loss. For group 2 patients, male sex (P = .005, OR = 1.656), higher body mass index (P = .002, OR = 0.946), a diagnosis other than osteoarthritis (P < .001, OR = 2.189), nonaugmented baseplate usage (P < .001, OR = 2.116), and not having subscapularis repaired (P < .001, OR = 3.052) were significant risk factors for IR loss. CONCLUSION The majority of patients improve IR after rTSA in the nonfracture setting. rTSA patients with substantial IR prior to surgery had a greater probability for losing IR compared to patients with poor preoperative IR. Numerous risk factors for IR loss were identified; these risk factors are useful for counseling patients considering rTSA, as some patients are more likely to lose IR than others.
Collapse
Affiliation(s)
- Eric Rohman
- Park Nicollet TRIA Orthopedic Center, Maple Grove, MN, USA
| | - Joseph J King
- Department of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | | | - Wen Fan
- Exactech, Gainesville, FL, USA
| | | | | |
Collapse
|
30
|
Shoulder arthroplasty for proximal humeral fracture treatment: a retrospective functional outcome analysis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2022:10.1007/s00590-022-03313-z. [PMID: 35759106 DOI: 10.1007/s00590-022-03313-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Accepted: 06/06/2022] [Indexed: 10/17/2022]
Abstract
PURPOSE Following proximal humeral fractures hemiarthroplasty (HA) or reversed total shoulder arthroplasty (rTSA) are performed if osteosynthesis or conservative treatment is not possible. HA has been reported to result in decreased functional outcomes compared with rTSA. Secondary shoulder arthroplasty, performed after a different initial treatment, has also been associated with inferior outcomes. METHODS Patients recieving a shoulder arthroplasty related to a proximal humeral fracture from 2010 to 2019 were included. A retrospective analysis of functional outcomes was performed using QuickDASH and subjective shoulder value (SSV). RESULTS The mean [standard deviation (SD)] follow-up time among the 82 included patients was 48 (28) months. The mean age was 70 (10) years. The mean age for HA was significantly different from rTSA [57 (9) and 72 (21) years; p < .001]. The mean QuickDASH score for primary arthroplasty was 11 (2) versus 12 (16) for secondary arthroplasty (p = .313). The mean SSV for primary arthroplasty was 84 (22) versus 82 (17) for secondary arthroplasty (p = .578). The mean QuickDASH score for HA was 24 (36) versus 9 (15) for rTSA (p = .346). The mean SSV for HA was 70 (34) versus 86 (17) for rTSA (p = .578). CONCLUSION Functional outcomes after fracture-related shoulder arthroplasty were excellent in an older population, even when performed secondarily after failed primary osteosynthesis or conservative treatment. No significant differences in shoulder function were identified between rTSA and HA, likely due to restrictive indications for HA.
Collapse
|
31
|
Effect of glenosphere size on reverse shoulder arthroplasty revision rate: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). J Shoulder Elbow Surg 2022; 31:e289-e301. [PMID: 34968690 DOI: 10.1016/j.jse.2021.11.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 11/13/2021] [Accepted: 11/16/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Modularity is an integral element of reverse total shoulder arthroplasty (RTSA). Glenosphere diameter is a key component, but its effect on revision rate is unknown. The aim of this study was to investigate the relationship between glenosphere size and revision rates in RTSA procedures. METHODS Data from a large national arthroplasty registry were analyzed for the period April 2004 to 31 December 2019. The study population included all primary RTSA procedures using glenosphere sizes <38 mm, 38-40 mm, and >40 mm. A subanalysis of glenosphere sizes for each of the 3 most commonly implanted prostheses and further analyses by patient age and gender were also performed. The rate of revision was determined by Kaplan-Meier estimates, with comparisons by Cox proportional hazard models. RESULTS There were 28,817 primary RTSA procedures. Glenosphere sizes <38 mm had a higher revision rate compared to 38-40-mm glenospheres (hazard ratio [HR] 1.28, 95% confidence interval [CI] 1.11, 1.48, P < .001) and >40-mm sizes (HR 1.35, 95% CI 1.15, 1.59, P < .001). Males with <38-mm and 38-40-mm glenospheres had significantly higher revision rates compared to >40-mm glenospheres (HR 1.49, 95% CI 1.21, 1.83, P < .001; and HR 1.28, 95% CI 1.03, 1.58, P = .025, respectively). Females with <38-mm and >40-mm glenospheres had higher revision rates compared to females with 38-40-mm glenospheres (HR 1.38, 95% CI 1.14, 1.68, P < .001; and HR 1.41, 95% CI 1.06, 1.88, P = .019, respectively). For patients aged 65-74 years, glenospheres >40 mm had a significantly lower revision rate than both the <38-mm glenospheres (entire period: HR 0.59, 95% CI 0.45, 0.76, P < .001) and 38-40-mm glenospheres (entire period: HR 0.72, 95% CI 0.54, 0.94, P = .017). For patients aged ≥75 years (n = 14,622), <38-mm glenospheres had a significantly higher rate of revision compared with 38-40-mm glenospheres after 3 months (HR 1.43, 95% CI 1.09, 1.86, P = .009). Analysis comparing glenosphere sizes within each of the 3 most commonly implanted prostheses found that the Delta Xtend with 38-40-mm glenospheres had higher revision rates compared with >40-mm glenospheres (HR 1.49, 95% CI 1.14, 1.92, P = .003). The SMR L1 (Lima) 38-40-mm glenospheres had a lower rate of revision compared with the <38-mm (HR 0.50, 95% CI 0.37, 0.67, P < .001) and >40-mm glenospheres (HR 0.60, 95% CI 0.43, 0.85, P = .004). CONCLUSIONS Glenospheres <38 mm can be expected to increase revision rates in primary RTSAs. The optimum size of glenospheres is gender, age, and prosthesis specific, with revision rates lower for females with 38-40-mm glenospheres and lower for males with >40-mm glenospheres.
Collapse
|
32
|
Lilley BM, Lachance A, Peebles AM, Powell SN, Romeo AA, Denard PJ, Provencher CMT. What is the deviation in 3D preoperative planning software? A systematic review of concordance between plan and actual implant in reverse total shoulder arthroplasty. J Shoulder Elbow Surg 2022; 31:1073-1082. [PMID: 35017079 DOI: 10.1016/j.jse.2021.12.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 12/02/2021] [Accepted: 12/04/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Three-dimensional (3D) preoperative planning software for reverse total shoulder arthroplasty (rTSA) has been implemented in recent years in order to increase accuracy, improve efficiency, and add value to the outcome. A comprehensive literature review is required to determine the utility of preoperative 3D planning software in guiding orthopedic surgeons for implant placement in rTSA. We hypothesize that implementation of 3D preoperative planning software in the setting of rTSA leads to high concordance with minimal deviation from the preoperative plan. METHODS A comprehensive and iterative literature review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) using the PubMed, Embase, OVID Medline, Scopus, Cinahl, Web of Science, and Cochrane databases for original English-language studies evaluating the impact of preoperative planning software usage on rTSA outcomes published from January 1, 2000, to present. Blinded reviewers conducted multiple screens. All included studies were graded based on level of evidence, and data concerning patient demographics and postoperative outcomes were extracted. RESULTS Nine articles met inclusion criteria (1 level II, 3 level III, and 5 level IV articles), including 415 patients and 422 shoulders. Of the patients who underwent rTSA, 235 were female and 140 were male, although 3 studies (n = 40) did not report sex breakdowns for rTSA patients. The average age was 72.7 years. Four studies (79 shoulders) reported implant final position as mean deviation from planned version and planned inclination. Six studies (n = 236) reported screw angle deviation, fixation, length, and concordance. Concordance with the preoperative plan was measured in 3 studies (n = 178), resulting in complete concordance of 90% (n = 100), arthroplasty type concordance (rTSA vs. TSA) of 100% (n = 100), and glenosphere size concordance between 93% (n = 100) and 88% (n = 76). For screw length concordance, baseplate screw matched by 81% (n = 76) and 100% (n = 2), and upper (n = 35) and lower (n = 35) screw length concordance was observed as 74% and 69%, respectively. The use of preoperative planning (n = 178) was associated with low deviation from preoperative plan, more 2-screw fixations, and longer average screw length in comparison with an unplanned cohort. CONCLUSION The use of preoperative planning software in the setting of rTSA results in minimal deviation from preoperative plan. High levels of concordance in screw angle, screw length, and glenosphere size were observed. Further prospective studies should be conducted to further substantiate these results.
Collapse
Affiliation(s)
| | | | | | - Sarah N Powell
- Georgetown University School of Medicine, Washington, DC, USA
| | - Anthony A Romeo
- Department of Orthopaedic Surgery, DuPage Medical Group, Chicago, IL, USA
| | | | | |
Collapse
|
33
|
Youn SM, Lee HS, Rhee SM, Rhee YG. Medialized vs. lateralized humeral implant in reverse total shoulder arthroplasty: the comparison of outcomes in pseudoparalysis with massive rotator cuff tear. J Shoulder Elbow Surg 2022; 31:736-746. [PMID: 34543745 DOI: 10.1016/j.jse.2021.08.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 08/07/2021] [Accepted: 08/10/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND With the increasing use of lateralized humeral implants in reverse total shoulder arthroplasty (RTSA), it is still unclear whether this design will be as advantageous as the medialized humeral implants in the setting of pseudoparalysis (PP). METHODS A total of 51 eligible RTSA cases for PP signs due to massive rotator cuff deficiency were selected for the retrospective review. Twenty-five patients were allocated to group L in which the isolated humeral side lateralization was performed (neck-shaft angle of 145°), and 26 patients were allocated to group M (neck-shaft angle of 155°). Pre- and postoperative radiologic measurements including critical shoulder angle, acromiohumeral distance (AHD), lateral humeral offset (LHO), and deltoid wrapping offset (DWO), as well as range of motion (ROM) and clinical outcome scores, were compared. The mean age was 71.0 ± 6.5 years for group L and 70.3 ± 7.0 years for group M, and the overall mean follow-up period was 49.0 ± 13.5 months (range, 25.7-68.9). RESULTS The preoperative radiologic measurements were similar, but the postoperative LHO and DWO were significantly larger for group L, whereas the postoperative AHD was larger for group M compared with group L, with the values being 39.8 ± 9.7 mm and 33.6 ± 10.4 mm, respectively (P = .034). For the ROM, active forward elevation did improve significantly for both, starting preoperatively with the active ranges of 39° ± 19° (passively 153° ± 24°) for group L and 42° ± 18° (passively 156° ± 11°) for group M-the final postoperative active ranges being 142° ± 16° and 133° ± 33°, respectively, without significant difference between the groups (P = .426). The postoperative recovery of PP for group L was 100% (25 of 25), whereas for group M, it was 96.2% (25 of 26). The final visual analog scale (VAS) scores and University of California Los Angeles (UCLA) shoulder scores improved significantly for both groups, but the differences between the groups at the final assessments were insignificant. The 4 complications were periprosthetic fracture, acromial stress fracture, periprosthetic joint infection, and neuropraxia, all of which were in group M, and scapular notching with higher grades were more prevalent for group M (26.9%, 7 of 26). CONCLUSIONS With RTSA, good outcomes and recovery were achieved in most cases of PP. The postoperative active elevation range and functional outcomes were not affected by medialization or lateralization of the humeral implant. Earlier recovery of motion was observed with the lateralized group, but no significant differences were seen in the final ROM between the groups.
Collapse
Affiliation(s)
- Seung-Min Youn
- Department of Orthopaedic Surgery, Royal Brisbane and Women's Hospital, Herston, QLD, Australia
| | - Hee Sung Lee
- Shoulder & Elbow Clinic, Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University Hospital, Seoul, Republic of Korea
| | - Sung-Min Rhee
- Shoulder & Elbow Clinic, Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University Hospital, Seoul, Republic of Korea
| | - Yong Girl Rhee
- Shoulder & Elbow Clinic, Department of Orthopaedic Surgery, Myongji Hospital, Goyang-si, Gyeonggi-do, Republic of Korea.
| |
Collapse
|
34
|
Como C, LeVasseur C, Kane G, Rai A, Munsch M, Gabrielli A, Hughes J, Anderst W, Lin A. Implant characteristics affect in vivo shoulder kinematics during multiplanar functional motions after reverse shoulder arthroplasty. J Biomech 2022; 135:111050. [PMID: 35313249 PMCID: PMC9064972 DOI: 10.1016/j.jbiomech.2022.111050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 03/08/2022] [Accepted: 03/09/2022] [Indexed: 11/21/2022]
Abstract
The purpose of this study was to determine how implant characteristics affect in vivo shoulder kinematics after reverse shoulder arthroplasty (RSA). Kinematics of the affected upper limb were measured in 32 participants during five motions (scapular plane abduction, hand-to-head, hand-to-back, internal/external rotation at 90° abduction, and circumduction) using optical motion capture. Shoulder abduction, plane of elevation, and internal/external rotation range of motion (ROM), peak angles, and continuous kinematics waveforms were calculated for each motion. Multiple regression was used to identify associations between kinematics and implant characteristics of lateralization, humeral retroversion, glenosphere size, glenosphere tilt, glenoid eccentricity, and implant neck-shaft angle (135° or 145°). Less humeral retroversion was associated with greater shoulder rotation ROM (p = 0.036) and greater plane of elevation ROM (p = 0.024) during circumduction, while less eccentricity was associated with more posterior plane of elevation during hand-to-back (p = 0.021). The 145° implant was associated with greater internal/external shoulder rotation ROM (p < 0.001), greater internal shoulder rotation (p = 0.002), and greater plane of elevation ROM (p = 001) during the hand-to-back. The 145° implant was also associated with more internal/external rotation ROM (p = 0.043) during shoulder rotation and more abduction ROM during circumduction (p = 0.043). During the hand-to-back motion, individuals having 135° neck-shaft angle implants were more abducted from 21 to 51% of the motion and were less internally rotated from 70 to 100% of the motion, while more lateralization was associated with less internal rotation from 90 to 100% of the motion. Retroversion and implant neck-shaft angle are the primary implant characteristics associated with in vivo shoulder kinematics during complex motions after RSA.
Collapse
Affiliation(s)
- Christopher Como
- University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - Clarissa LeVasseur
- University of Pittsburgh Department of Orthopaedic Surgery, Pittsburgh, PA, USA
| | - Gillian Kane
- University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - Ajinkya Rai
- University of Pittsburgh Department of Orthopaedic Surgery, Pittsburgh, PA, USA
| | - Maria Munsch
- University of Pittsburgh Department of Orthopaedic Surgery, Pittsburgh, PA, USA
| | - Alexandra Gabrielli
- University of Pittsburgh Department of Orthopaedic Surgery, Pittsburgh, PA, USA
| | - Jonathan Hughes
- University of Pittsburgh Department of Orthopaedic Surgery, Pittsburgh, PA, USA
| | - William Anderst
- University of Pittsburgh Department of Orthopaedic Surgery, Pittsburgh, PA, USA.
| | - Albert Lin
- University of Pittsburgh Department of Orthopaedic Surgery, Pittsburgh, PA, USA
| |
Collapse
|
35
|
Weisse B, Lama S, Piskoty G, Affolter C, Aiyangar AK. Effect of two types of shoulder prosthesis on the muscle forces using a generic multibody model for different arm motions. Biomed Eng Online 2022; 21:17. [PMID: 35305644 PMCID: PMC8934495 DOI: 10.1186/s12938-022-00988-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 03/07/2022] [Indexed: 11/10/2022] Open
Abstract
Background This study aims to analyze the effects of a novel dual-bearing shoulder prosthesis and a conventional reverse shoulder prosthesis on the deltoid and rotator cuff muscle forces for four different arm motions. The dual-bearing prosthesis is a glenoid-sparing joint replacement with a moving center of rotation. It has been developed to treat rotator cuff arthropathy, providing an increased post-operative functionality. Methods A three-dimensional musculoskeletal OpenSim® model of an upper body, incorporating a natural gleno-humeral joint and a scapula-thoracic joint developed by Blana et al. (J Biomech 41: 1714-1721, 2008), was used as a reference for the natural shoulder. It was modified by integrating first a novel dual-bearing prosthesis, and second, a reverse shoulder prosthesis into the shoulder joint complex. Four different arm motions, namely abduction, scaption, internal and external rotation, were simulated using an inverse kinematics approach. For each of the three models, shoulder muscle forces and joint reaction forces were calculated with a 2 kg weight in the hand. Results In general, the maximal shoulder muscle force and joint reaction force values were in a similar range for both prosthesis models during all four motions. The maximal deltoid muscle forces in the model with the dual-bearing prosthesis were 18% lower for abduction and 3% higher for scaption compared to the natural shoulder. The maximal rotator cuff muscle forces in the model with the dual-bearing prosthesis were 36% lower for abduction and 1% higher for scaption compared to the natural shoulder. Although the maximal deltoid muscle forces in the model with the dual-bearing prosthesis in internal and external rotation were 52% and 64% higher, respectively, compared to the natural shoulder, the maximal rotator cuff muscle forces were 27% lower in both motions. Conclusion The study shows that the dual-bearing shoulder prosthesis is a feasible option for patients with rotator cuff tear and has a strong potential to be used as secondary as well as primary joint replacement. The study also demonstrates that computer simulations can help to guide the continued optimization of this particular design concept for successful clinical outcomes.
Collapse
|
36
|
The Evolution of Reverse Total Shoulder Arthroplasty-From the First Steps to Novel Implant Designs and Surgical Techniques. J Clin Med 2022; 11:jcm11061512. [PMID: 35329837 PMCID: PMC8949196 DOI: 10.3390/jcm11061512] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 03/06/2022] [Accepted: 03/08/2022] [Indexed: 02/04/2023] Open
Abstract
Purpose of Review: The purpose of this review is to summarize recent literature regarding the latest design modifications and biomechanical evolutions of reverse total shoulder arthroplasty and their impact on postoperative outcomes. Recent findings: Over the past decade, worldwide implantation rates of reverse total shoulder arthroplasty have drastically increased for various shoulder pathologies. While Paul Grammont’s design principles first published in 1985 for reverse total shoulder arthroplasty remained unchanged, several adjustments were made to address postoperative clinical and biomechanical challenges such as implant glenoid loosening, scapular notching, or limited range of motion in order to maximize functional outcomes and increase the longevity of reverse total shoulder arthroplasty. However, the adequate and stable fixation of prosthetic components can be challenging, especially in massive osteoarthritis with concomitant bone loss. To overcome such issues, surgical navigation and patient-specific instruments may be a viable tool to improve accurate prosthetic component positioning. Nevertheless, larger clinical series on the accuracy and possible complications of this novel technique are still missing.
Collapse
|
37
|
Freislederer F, Toft F, Audigé L, Marzel A, Endell D, Scheibel M. Lateralized vs. classic Grammont-style reverse shoulder arthroplasty for cuff deficiency Hamada stage 1-3: does the design make a difference? J Shoulder Elbow Surg 2022; 31:341-351. [PMID: 34450279 DOI: 10.1016/j.jse.2021.07.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 07/21/2021] [Accepted: 07/26/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) with a lateralized design is thought to improve outcomes. Our aim was to compare RSA with the classic Grammont prosthesis against a prosthesis with 135° inclination and a lateralized glenosphere for cuff-deficient shoulders. METHODS Patients with irreparable massive posterosuperior rotator cuff tear Hamada grade 1-3 underwent RSA and were documented prospectively up to 24 months postsurgery. Comparative RSA groups were "lateralized" (L), with 135° humeral inclination and 36+4-mm lateralized glenosphere (n = 44), and "Grammont" (G), with 155° humeral inclination and 36+2-mm eccentric glenosphere (n = 23). Range of motion including the Apley scratch test, abduction strength, Constant-Murley score (CS), and Shoulder Pain and Disability Index (SPADI) were assessed. Anteroposterior and axial radiographs were evaluated at 24 months, and additional measurements of scapular neck and glenoid anatomy, baseplate and glenosphere position, center of rotation, humeral offset, and lateralization and distalization shoulder angles were made. Linear regression and mixed models adjusted for sex differences and preoperative values were applied. RESULTS Overall CS and SPADI outcomes were not significantly different between groups (P ≥ .654). For group L, external rotation remained stable up to the 2-year follow-up and was higher than for group G (P = .012 ); a greater proportion of group L patients could reach the lumbar vertebra 3 (L3) (70% vs. 48% in group G) (P = .26). Group G had a higher inferior glenosphere overhang (P = .020) and center of rotation (COR) medialization (P < .001), whereas group L had higher humeral offset (P < .001) and lateralization shoulder angle (P < .001) with a trend toward higher baseplate positioning (P = .045). The rate of scapular notching was 2.9 times higher for group G than group L (P = .001). CONCLUSION RSA with 135° humeral inclination and a lateralized glenosphere shows similar outcome scores as the classic Grammont design but enables better preservation of external rotation and reduces the rate of scapular notching compared with the classic Grammont design in Hamada 1-3 patients with irreparable posterosuperior tears.
Collapse
Affiliation(s)
| | - Felix Toft
- Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | - Laurent Audigé
- Research and Development, Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | - Alex Marzel
- Research and Development, Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | - David Endell
- Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | - Markus Scheibel
- Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland; Charité-Universitaetsmedizin Berlin, Berlin, Germany.
| |
Collapse
|
38
|
Haidamous G, Lädermann A, Hartzler RU, Parsons BO, Lederman ES, Tokish JM, Denard PJ. Radiographic parameters associated with excellent versus poor range of motion outcomes following reverse shoulder arthroplasty. Shoulder Elbow 2022; 14:39-47. [PMID: 35154401 PMCID: PMC8832695 DOI: 10.1177/1758573220936234] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 05/27/2020] [Accepted: 05/28/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND The purpose was to evaluate the relationship of component size and position to postoperative range of motion following reverse shoulder arthroplasty. The hypothesis was that increased lateralization, larger glenospheres, and a decreased acromiohumeral distance would be associated with excellent postoperative range of motion. METHODS A retrospective multicenter study was performed at a minimum of one year postoperatively on 160 patients who underwent primary reverse shoulder arthroplasty with a 135° humeral component. Outcomes were stratified based on postoperative forward flexion and external rotation into excellent (n = 42), defined as forward flexion >140° and external rotation > 30°, or poor (n = 36), defined as forward flexion <100° and external rotation < 15°. Radiographic measurements and component features were compared between the two groups. RESULTS A larger glenosphere size was associated with an excellent outcome (p = 0.009). A 2-mm posterior offset humeral cup (p = 0.012) and an increased inferior glenosphere overhang (3.1 mm vs 1.4 mm; p = 0.002) were also associated with excellent outcomes. Humeral lateralization and distalization were not associated with an excellent outcome.Conclusion: Larger glenosphere size and inferior positioning as well as posterior humeral offset are associated with improved postoperative range of motion following reverse shoulder arthroplasty. LEVEL OF EVIDENCE Level 3, retrospective comparative study.
Collapse
Affiliation(s)
| | - Alexandre Lädermann
- Division of Orthopedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
| | | | | | - Evan S Lederman
- University of Arizona College of Medicine Phoenix and the Orthopedic Clinic Association, Phoenix, AZ, USA
| | | | - Patrick J Denard
- Southern Oregon Orthopedics, Medford, OR, USA,Department of Orthopaedic & Rehabilitation, Oregon Health & Science University, Portland, OR, USA,Patrick J Denard, Southern Oregon Orthopedics, 2780 E. Barnett Road, Suite 200, Medford, OR 97530, USA.
| |
Collapse
|
39
|
Reverse Shoulder Arthroplasty Biomechanics. J Funct Morphol Kinesiol 2022; 7:jfmk7010013. [PMID: 35225900 PMCID: PMC8883988 DOI: 10.3390/jfmk7010013] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/11/2022] [Accepted: 01/17/2022] [Indexed: 12/03/2022] Open
Abstract
The reverse total shoulder arthroplasty (rTSA) prosthesis has been demonstrated to be a viable treatment option for a variety of end-stage degenerative conditions of the shoulder. The clinical success of this prosthesis is at least partially due to its unique biomechanical advantages. As taught by Paul Grammont, the medialized center of rotation fixed-fulcrum prosthesis increases the deltoid abductor moment arm lengths and improves deltoid efficiency relative to the native shoulder. All modern reverse shoulder prostheses utilize this medialized center of rotation (CoR) design concept; however, some differences in outcomes and complications have been observed between rTSA prostheses. Such differences in outcomes can at least partially be explained by the impact of glenoid and humeral prosthesis design parameters, surgical technique, implant positioning, patient-specific bone morphology, and usage in humeral and glenoid bone loss situations on reverse shoulder biomechanics. Ultimately, a better understanding of the reverse shoulder biomechanical principles will guide future innovations and further improve clinical outcomes.
Collapse
|
40
|
Collotte P, Bercik M, Vieira TD, Walch G. Long-term Reverse Total Shoulder Arthroplasty Outcomes: The Effect of the Inferior Shifting of Glenoid Component Fixation. Clin Orthop Surg 2021; 13:505-512. [PMID: 34868500 PMCID: PMC8609210 DOI: 10.4055/cios20245] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Revised: 12/28/2020] [Accepted: 12/28/2020] [Indexed: 11/30/2022] Open
Abstract
Backgroud The 155° Grammont reverse shoulder replacement has a long track record of success, but also a high radiographic notching rate. The increased distance between the scapular pillar and the humeral component theoretically decreases postoperative notching. The glenoid component can be shifted inferiorly relative to the glenoid; however, there also is some concern that shifting the glenoid component too far inferiorly (inferior glenoid component overhang > 3.5 mm) may compromise long-term stability of the glenoid component. This study was conducted to determine if clinical outcomes, scapular notching, and complications vary with more inferior placement of the glenoid component. Methods A retrospective analysis of prospectively collected data was performed in order to compare radiographic outcomes (notching rate and signs of glenoid loosening or component disassembly) and clinical outcomes (range of motion, Constant score, subjective shoulder value, and complication rate) of all patients who underwent reverse shoulder replacement with the glenosphere positioned either flush with the inferior rim of the glenoid (flush group) or with at least 3.5 mm of inferior overhang (overhang group) at a minimum follow-up of 60 months. Ninety-seven patients ultimately met the inclusion criteria, with 41 patients with flush glenoid component and 56 patients with at least 3.5 mm of inferior overhang. Results Average follow-up was 97.8 months. The overhang group had a lower rate of radiographic notching (37% vs. 82.5%, p < 0.05), better clinical outcomes (improvement in Constant score: +40 vs. +32, p = 0.036), and higher subjective shoulder value (79 vs. 69, p = 0.026) than the flush group. No difference in complications between groups was found. Conclusions In this study, at least 3.5 mm of inferior glenosphere overhang relative to the inferior rim of the glenoid was associated with the lower notching rate without negative effect on the clinical outcomes in 155° Grammont-style reverse shoulder replacement. Therefore, no increase in complications should be expected when using this surgical technique.
Collapse
Affiliation(s)
- Philippe Collotte
- Centre Orthopedique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Generale de Sante, Hopital Prive Jean Mermoz, Lyon, France
| | | | - Thais Dutra Vieira
- Centre Orthopedique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Generale de Sante, Hopital Prive Jean Mermoz, Lyon, France
| | - Gilles Walch
- Centre Orthopedique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Generale de Sante, Hopital Prive Jean Mermoz, Lyon, France
| |
Collapse
|
41
|
Characterizing the trade-off between range of motion and stability of reverse total shoulder arthroplasty. J Shoulder Elbow Surg 2021; 30:2804-2813. [PMID: 34020003 PMCID: PMC8595519 DOI: 10.1016/j.jse.2021.05.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 04/22/2021] [Accepted: 05/02/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND The trade-off between range of motion (ROM) and stability of reverse total shoulder arthroplasty (RSA) has long been hypothesized to exist but has not yet been well characterized. The goal of this study was to use design optimization techniques to obtain a Pareto curve, which quantifies the trade-off between 2 competing objectives and is defined by the performance of optimum designs that maximize one surgical outcome without sacrificing the other. METHODS Multi-objective design optimization techniques were used; 4 design and surgical parameters including glenoid lateralization (GLat), neck-shaft angle (NSA), inferior offset of the center of rotation (CORinf), and humerus lateralization (HLat) were tuned simultaneously. The ROM and stability, the objectives to be optimized, of any candidate design were characterized computationally using a combination of finite element models, musculoskeletal models, analytical equations, and surrogate models. Optimum designs and Pareto curves were determined separately for a standard cup depth and a shallow cup depth. The performance of the optimum designs, in terms of ROM and stability, was compared with a representative commercially available design. RESULTS A Pareto curve was obtained for each cup depth, confirming there is a trade-off between ROM and stability of RSA. In comparison to the commercially available design (cup depth, 8.1 mm; GLat, 5 mm; NSA, 155°; CORinf, 0 mm; HLat, 0 mm), the designs optimized for ROM offered 38.8% (cup depth, 6 mm; GLat, 16 mm; NSA, 163.6°; CORinf, 4 mm; HLat, 0.6 mm) and 35.2% (cup depth, 8.1 mm; GLat, 16 mm; NSA, 160.5°; CORinf, 4 mm; HLat, -0.2 mm) improvement in ROM. The designs optimized for stability (cup depth of 6 mm with GLat of 16 mm, NSA of 170°, CORinf of 4 mm, and HLat of 3 mm and cup depth of 8.1 mm with GLat of 16 mm, NSA of 170°, CORinf of 4 mm, and HLat of 3 mm) both offered 12.4% improvement in stability over the commercially available design. Designs in the toe region of the Pareto curve offered between 75% and 90% of the maximum possible improvement over the commercially available design for both objectives. CONCLUSION It was confirmed that a trade-off exists between ROM and stability of RSA, in which maximizing one outcome requires a sacrifice in the other. The relative gains and sacrifices in the competing outcomes when traversing the Pareto front could aid in understanding clinically optimum designs based on patient-specific needs.
Collapse
|
42
|
Bohonos CJ, Russell SP, Morrissey DI. CT versus MRI planning for reverse geometry total shoulder arthroplasty. J Orthop 2021; 28:21-25. [PMID: 34744377 DOI: 10.1016/j.jor.2021.10.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 08/04/2021] [Accepted: 10/10/2021] [Indexed: 11/25/2022] Open
Abstract
Introduction Preoperative planning for Reverse Total Shoulder Arthroplasty (RTSA) using CT or MRI is well described.1, 2, 3, 4, 5, 6, 7 We aimed to compare pre-operative CT versus MRI measurement accuracy for predicting intra-operative glenoid implant sizing. Methods All patients with a preoperative CT or MRI undergoing RTSA at our tertiary referral center from October 2017 to February 2020 were included. Data was collected from theatre and implant registers. Glenosphere Width (GW) and Baseplate Central Screw Length (BCSL) were independently predicted from pre-operative CT or MRI imaging by 2 blinded senior authors. A sub-group analysis was also performed between trauma and non-trauma CT cases. SPSS v26 was used for statistical comparison between predicted and actual implants. Results 71 data sets from 69 patients were included for analysis: 31 CT predictions and 40 MRI predictions. 61.3% of CT measured GW predictions were accurate compared to 82.5% of MRI predictions (p = 0.045). BCSL predictions were 77.4% and 70% accurate for CT and MRI respectively, without significant difference. There was no significant difference in sub-group analysis for trauma vs elective CT accuracy of BCSL or GW measurements. Conclusion MRI imaging may be superior to CT for predicting GW and no less accurate than CT for predicting BCSL in the elective setting. No difference in CT measurement accuracy was seen between trauma and elective settings. While simultaneously clearly defining shoulder soft tissue anatomy, MRI may also be the preferred modality for bony measurements during pre-operative planning for elective RTSA.
Collapse
Affiliation(s)
- Colton J Bohonos
- University College Cork, Cork, Ireland.,Department of Trauma and Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland.,Cork University Hospital, Cork, Ireland
| | - Shane P Russell
- University College Cork, Cork, Ireland.,Department of Trauma and Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland.,Royal College of Surgeons, Dublin, Ireland
| | - David I Morrissey
- University College Cork, Cork, Ireland.,Department of Trauma and Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland.,Cork University Hospital, Cork, Ireland.,Royal College of Surgeons, Dublin, Ireland
| |
Collapse
|
43
|
Nabergoj M, Denard PJ, Collin P, Trebše R, Lädermann A. Radiological changes, infections and neurological complications after reverse shoulder arthroplasty related to different design types and their rates: Part II. EFORT Open Rev 2021; 6:1109-1121. [PMID: 34909229 PMCID: PMC8631237 DOI: 10.1302/2058-5241.6.210040] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
Early reported complication rates with the Grammont-type reverse shoulder arthroplasty (RSA) were very high, up to 24%.A 'problem' is defined as an intraoperative or postoperative event that is not likely to affect the patient's final outcome, such as intraoperative cement extravasation and radiographic changes. A 'complication' is defined as an intraoperative or postoperative event that is likely to affect the patient's final outcome, including infection, neurologic injury and intrathoracic central glenoid screw placement.Radiographic changes around the glenoid or humeral components of the RSA are very frequently observed and described in the literature.High complication rates related to the Grammont RSA design led to development of non-Grammont designs which led to a dramatic fall in the majority of complications.The percentage of radiological changes after RSA is not negligible and remains unsolved, despite a decrease in its occurrence in the last decade. However, such changes should be now considered as simple problems because they rarely have a negative influence on the patient's final outcome, and their prevalence has dramatically decreased.With further changes in indications and designs for RSA, it is crucial to accurately track the rates and types of complications to justify its new designs and increased indications. Cite this article: EFORT Open Rev 2021;6:1109-1121. DOI: 10.1302/2058-5241.6.210040.
Collapse
Affiliation(s)
- Marko Nabergoj
- Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | | | - Philippe Collin
- Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint- Grégoire, France
| | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
44
|
Nabergoj M, Denard PJ, Collin P, Trebše R, Lädermann A. Mechanical complications and fractures after reverse shoulder arthroplasty related to different design types and their rates: part I. EFORT Open Rev 2021; 6:1097-1108. [PMID: 34909228 PMCID: PMC8631242 DOI: 10.1302/2058-5241.6.210039] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The initial reverse shoulder arthroplasty (RSA), designed by Paul Grammont, was intended to treat rotator cuff tear arthropathy in elderly patients. In the early experience, high complication rates (up to 24%) and revision rates (up to 50%) were reported.The most common complications reported were scapular notching, whereas clinically more relevant complications such as instability and acromial fractures were less commonly described.Zumstein et al defined a 'complication' following RSA as any intraoperative or postoperative event that was likely to have a negative influence on the patient's final outcome.High rates of complications related to the Grammont RSA design led to development of non-Grammont designs, with 135 or 145 degrees of humeral inclination, multiple options for glenosphere size and eccentricity, improved baseplate fixation which facilitated glenoid-sided lateralization, and the option of humeral-sided lateralization.Improved implant characteristics combined with surgeon experience led to a dramatic fall in the majority of complications. However, we still lack a suitable solution for several complications, such as acromial stress fracture. Cite this article: EFORT Open Rev 2021;6:1097-1108. DOI: 10.1302/2058-5241.6.210039.
Collapse
Affiliation(s)
- Marko Nabergoj
- Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Patrick J. Denard
- Department of Orthopaedic & Rehabilitation, Oregon Health & Science University, Portland, Oregon, USA
| | - Philippe Collin
- Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint-Grégoire, France
| | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
45
|
Goetti P, Denard PJ, Collin P, Ibrahim M, Mazzolari A, Lädermann A. Biomechanics of anatomic and reverse shoulder arthroplasty. EFORT Open Rev 2021; 6:918-931. [PMID: 34760291 PMCID: PMC8559568 DOI: 10.1302/2058-5241.6.210014] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
The biomechanics of the shoulder relies on careful balancing between stability and mobility. A thorough understanding of normal and degenerative shoulder anatomy is necessary, as the goal of anatomic total shoulder arthroplasty is to reproduce premorbid shoulder kinematics.With reported joint reaction forces up to 2.4 times bodyweight, failure to restore anatomy and therefore provide a stable fulcrum will result in early implant failure secondary to glenoid loosening.The high variability of proximal humeral anatomy can be addressed with modular stems or stemless humeral components. The development of three-dimensional planning has led to a better understanding of the complex nature of glenoid bone deformity in eccentric osteoarthritis.The treatment of cuff tear arthropathy patients was revolutionized by the arrival of Grammont's reverse shoulder arthroplasty. The initial design medialized the centre of rotation and distalized the humerus, allowing up to a 42% increase in the deltoid moment arm.More modern reverse designs have maintained the element of restored stability but sought a more anatomic postoperative position to minimize complications and maximize rotational range of motion. Cite this article: EFORT Open Rev 2021;6:918-931. DOI: 10.1302/2058-5241.6.210014.
Collapse
Affiliation(s)
- Patrick Goetti
- Division of Orthopaedics and Trauma Surgery, Centre Hospitalier |Universitaire Vaudois, Lausanne, Switzerland
| | - Patrick J. Denard
- Denard Department of Orthopaedic & Rehabilitation, Oregon Health & Science University, Portland, Oregon, United States
| | - Philippe Collin
- Collin Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint- Grégoire, France
| | - Mohamed Ibrahim
- Mohamed Ibrahim, Department of Orthopaedics and Trauma Surgery, Faculty of Medicine, Fayoum University, Fayoum, Egypt
| | - Adrien Mazzolari
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
46
|
Almeida A, Agostini DC, Nesello PF, de Almeida NC, Mioso R, Agostini AP. Tomographic Analysis of Positioning of Reverse Baseplates Positioning. J Shoulder Elb Arthroplast 2021; 5:2471549220987714. [PMID: 34497966 PMCID: PMC8282139 DOI: 10.1177/2471549220987714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 10/15/2020] [Accepted: 12/22/2020] [Indexed: 11/17/2022] Open
Abstract
Objective To verify whether reverse baseplate positioning without the support of intraoperative three-dimensional technology is within the acceptable parameters in the literature and whether glenoid bone deformity (GBD) compromises this positioning. Methods Sixty-nine reverse shoulder arthroplasties were evaluated with volumetric computed tomography (CT). Two radiologists performed blinded CT scan analysis and evaluated baseplate position within 2mm of the inferior glenoid; the inclination and version of the baseplate in relation to the Friedman line; and upper and lower screw and baseplate metallic peg end point positionings. The patients were divided according to the presence of GBD for statistical analyses. Results The two radiologists concurred reasonably in their interpretations of the following analyzed parameters: baseplate position within 2mm of the inferior glenoid rim (97.1% and 95.7%), baseplate inclination (82.6% and 81.2%), baseplate version (69.6% and 56.5%), the upper screw reaching the base of the coracoid process (71% and 79.7%), the inferior screw remaining inside the scapula (88.4% and 84.1%), and the metallic peg of the baseplate considered intraosseous (88.4% and 72.5%). Conclusion Reverse baseplate positioning without intraoperative three-dimensional technology is within the acceptable parameters of the literature, except for baseplate version and upper screw position. GBD did not interfere with baseplate positioning in reverse shoulder arthroplasty.
Collapse
Affiliation(s)
| | | | | | | | - Rafael Mioso
- Radiologist Physician, General Hospital, Caxias do Sul, Brazil
| | | |
Collapse
|
47
|
Tankshali K, Suh DW, Ji JH, Kim CY. Mid-term outcomes of bony increased offset-reverse total shoulder arthroplasty in the Asian population. Clin Shoulder Elb 2021; 24:125-134. [PMID: 34488292 PMCID: PMC8423532 DOI: 10.5397/cise.2021.00087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Accepted: 05/05/2021] [Indexed: 11/25/2022] Open
Abstract
Background To evaluate clinical and radiological outcomes of bony increased offset-reverse total shoulder arthroplasty (BIO-RSA) in the Asian population at mid-term follow-up. Methods From June 2012 to August 2017 at a single center, 43 patients underwent BIO-RSA, and 38 patients with minimum 2 years follow-up were enrolled. We evaluated the clinical and radiological outcomes, and complications at the last follow-up. In addition, we divided these patients into notching and no-notching groups and compared the demographics, preoperative, and postoperative characteristics of patients. Results Visual analogue scale, American Shoulder and Elbow Surgeons, University of California-Los Angeles Shoulder Scale, and Simple Shoulder Test scores improved significantly from preoperative (5.00, 3.93, 1.72, 3.94) to postoperative (1.72, 78.91, 28.34, 7.66) (p<0.05) outcomes. All range of motion except internal rotation improved significantly at the final follow-up (p<0.05), and the bone graft was well-incorporated with the native glenoid in all patients (100%). However, scapular notching was observed in 20 of 38 patients (53%). In the comparison between notching and no-notching groups (18 vs. 20 patients), there were no significant differences in demographics, radiological parameters, and clinical outcomes except acromion-greater tuberosity (AT) distance (p=0.003). Intraoperative complications included three metaphyseal fractures and one inferior screw malposition. Postoperative complications included ectopic ossification, scapular neck stress fracture, humeral stem relaxation, and late infection in one case each. Conclusions BIO-RSA showed improved clinical outcomes at mid-term follow-up in Asian population. However, we observed higher scapular notching compared to the previous studies. In addition, adequate glenoid lateralization with appropriate humeral lengthening (AT distance) might reduce scapular notching.
Collapse
Affiliation(s)
- Kirtan Tankshali
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | - Dong-Whan Suh
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | - Jong-Hun Ji
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | - Chang-Yeon Kim
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| |
Collapse
|
48
|
Werthel JD, Boux de Casson F, Burdin V, Athwal GS, Favard L, Chaoui J, Walch G. CT-based volumetric assessment of rotator cuff muscle in shoulder arthroplasty preoperative planning. Bone Jt Open 2021; 2:552-561. [PMID: 34315280 PMCID: PMC8329519 DOI: 10.1302/2633-1462.27.bjo-2021-0081.r1] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Aims The aim of this study was to describe a quantitative 3D CT method to measure rotator cuff muscle volume, atrophy, and balance in healthy controls and in three pathological shoulder cohorts. Methods In all, 102 CT scans were included in the analysis: 46 healthy, 21 cuff tear arthropathy (CTA), 18 irreparable rotator cuff tear (IRCT), and 17 primary osteoarthritis (OA). The four rotator cuff muscles were manually segmented and their volume, including intramuscular fat, was calculated. The normalized volume (NV) of each muscle was calculated by dividing muscle volume to the patient’s scapular bone volume. Muscle volume and percentage of muscle atrophy were compared between muscles and between cohorts. Results Rotator cuff muscle volume was significantly decreased in patients with OA, CTA, and IRCT compared to healthy patients (p < 0.0001). Atrophy was comparable for all muscles between CTA, IRCT, and OA patients, except for the supraspinatus, which was significantly more atrophied in CTA and IRCT (p = 0.002). In healthy shoulders, the anterior cuff represented 45% of the entire cuff, while the posterior cuff represented 40%. A similar partition between anterior and posterior cuff was also found in both CTA and IRCT patients. However, in OA patients, the relative volume of the anterior (42%) and posterior cuff (45%) were similar. Conclusion This study shows that rotator cuff muscle volume is significantly decreased in patients with OA, CTA, or IRCT compared to healthy patients, but that only minimal differences can be observed between the different pathological groups. This suggests that the influence of rotator cuff muscle volume and atrophy (including intramuscular fat) as an independent factor of outcome may be overestimated. Cite this article: Bone Jt Open 2021;2(7):552–561.
Collapse
Affiliation(s)
- Jean-David Werthel
- Hôpital Ambroise Paré, Boulogne-Billancourt, France.,Laboratory of Medical Information Processing, Brest, France
| | | | - Valérie Burdin
- Laboratory of Medical Information Processing, Brest, France
| | - George S Athwal
- Roth McFarlane Hand and Upper Limb Center, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | | | - Jean Chaoui
- Wright Medical, Montbonnot, France.,Tornier, Montbonnot, France.,Imascap, Plouzané, France.,Stryker, Kalamazoo, Michigan, USA
| | - Gilles Walch
- Centre Orthopédique Santy, Lyon, France.,Ramsay Générale de Santé, Hôpital Privé Jean Mermoz Lyon, Lyon, France
| |
Collapse
|
49
|
Bechtold DA, Ganapathy PK, Aleem AW, Chamberlain AM, Keener JD. The relationship between glenoid inclination and instability following primary reverse shoulder arthroplasty. J Shoulder Elbow Surg 2021; 30:e370-e377. [PMID: 33144223 DOI: 10.1016/j.jse.2020.09.037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 09/13/2020] [Accepted: 09/29/2020] [Indexed: 02/01/2023]
Abstract
PURPOSE Despite advances in implant design and surgical technique, instability remains the most common early complication and reason for early revision after reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the glenoid implant inclination, as measured by the β-angle, as an independent risk factor for instability after primary RSA. METHODS A retrospective case-control study was conducted matching cases with instability after primary RSA using a single implant to controls without instability. Controls were matched to age, sex, body mass index, and baseplate type (1:3 ratio of cases to controls). The preoperative, postoperative, and the change in pre- to postoperative glenoid inclination (β-angle) were compared between groups. RESULTS Thirty-four cases (mean age, 66.2 years) were matched to 102 controls (mean age, 67.0 years). There was a wide range of postoperative (63° to 100°) and pre- to postoperative change (-16.5° to +30.5°) in β-angles collectively. There was no significant difference in the postoperative β-angle (mean, 80.8° vs. 82.7°, P = .19) or the change in β-angle (mean, +1.7° vs. +3.4°, P = .35) between cases and controls, respectively. Regression analysis demonstrated no increased odds of instability with the postoperative β-angle, odds ratio 0.965 (confidence interval [CI] = 0.916-1.02, P = .19). Likewise, for the preoperative to postoperative change in β-angle, there was no significantly increased odds of instability, odds ratio 0.978 (CI = 0.934-1.03, P = .35). Finally, there was no difference in risk of instability in patients whose implant positioning resulted in a net superior increase in inclination, relative risk 0.85 (95% CI = 0.46-1.56, P = .28). CONCLUSIONS Neither the final prosthetic glenoid inclination nor the change in glenoid inclination, as measured by the β-angle, significantly influences the risk of prosthetic instability after primary RSA.
Collapse
Affiliation(s)
- Daniel A Bechtold
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Pramodh K Ganapathy
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Alexander W Aleem
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Aaron M Chamberlain
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Jay D Keener
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.
| |
Collapse
|
50
|
Lopiz Y, Galán-Olleros M, Rodriguez-Rodriguez L, García-Fernández C, Marco F. Radiographic changes around the glenoid component in primary reverse shoulder arthroplasty at mid-term follow-up. J Shoulder Elbow Surg 2021; 30:e378-e391. [PMID: 33197588 DOI: 10.1016/j.jse.2020.10.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 09/20/2020] [Accepted: 10/07/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Some local events after reverse shoulder arthroplasty (RSA) occur without the patient experiencing symptoms and yet may be detected on diagnostic imaging, thereby serving as indicators of future complications that may require revision. Most of these events involve the glenoid component, but radiographic studies evaluating this component are scarce, especially medium- and long-term studies. This study aimed to analyze the radiographic changes around the glenoid component and determine the risk factors associated with the presence of these radiographic changes. MATERIALS AND METHODS A retrospective review of 105 primary Grammont-style RSAs implanted between 2003 and 2014 was conducted. Radiographic outcomes were evaluated in patients with ≥5 years of radiographic follow-up. Standardized digital radiographs obtained immediately postoperatively and at a minimum follow-up time of 5 years were analyzed to determine (1) glenoid component position (inclination and height) and (2) minor radiographic changes (Sirveaux grade 1 or 2 scapular notching; nondisplaced acromial fracture; radiolucent lines around 1 or 2 screws; Brooker grade 1a, 1b, or 2 heterotopic calcifications; or single screw rupture), as well as major radiographic changes (Sirveaux grade 3 or 4 scapular notching; radiolucent lines around ≥3 screws or central peg; Brooker grade 1c or 3 heterotopic calcifications; prosthetic dislocation; loosening or migration; or disassembly). RESULTS Major radiologic changes were identified in 14.3% of the cases. Bivariate analysis showed that more changes were associated with the arthroplasties implanted in the first years of the study (odds ratio [OR] = 0.81, P = .012). This time-related variable was also associated with inclination (OR = 0.88, P = .045) and height (OR = 0.75, P = .001), improving in arthroplasties implanted in the last years of the study. Multivariate analysis revealed an increased risk of severe scapular notching mainly associated with superior tilt (OR = 2.52, P = .036) and a high (OR = 2.68, P = .019) or excessively high (OR = 7.55, P = .013) position and an increased risk of loosening signs associated with superior tilt (OR = 8.92, P = 9.1 × 10-6). CONCLUSIONS The percentage of radiologic changes of the glenoid component in RSA is considerable, despite the detection of a decrease in their presence among the arthroplasties implanted outside the initial period. Superior tilt and an excessively high position appear to be associated with a severe degree of scapular notching development and increased risk of radiographic loosening signs. Knowledge of the factors associated with major radiologic changes in the medium-term follow-up will help to optimize the primary surgical technique for each patient and indication, improving implant survival in primary RSA surgery.
Collapse
Affiliation(s)
- Yaiza Lopiz
- Shoulder and Elbow Unit, Department of Traumatology and Orthopaedic Surgery, Clínico San Carlos Hospital, Madrid, Spain; Department of Surgery, Complutense University, Madrid, Spain.
| | - María Galán-Olleros
- Shoulder and Elbow Unit, Department of Traumatology and Orthopaedic Surgery, Clínico San Carlos Hospital, Madrid, Spain
| | - Luis Rodriguez-Rodriguez
- Instituto de Investigación Sanitaria del Hospital Clínico San Carlos, UGC de Reumatología, Hospital Clínico San Carlos, Madrid, Spain
| | - Carlos García-Fernández
- Shoulder and Elbow Unit, Department of Traumatology and Orthopaedic Surgery, Clínico San Carlos Hospital, Madrid, Spain
| | - Fernando Marco
- Shoulder and Elbow Unit, Department of Traumatology and Orthopaedic Surgery, Clínico San Carlos Hospital, Madrid, Spain; Department of Surgery, Complutense University, Madrid, Spain
| |
Collapse
|